Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
655 Panama Lane (3)
SENTVIAUSMAILANDELECTRONICMAIL August3,2022 Applicant BHTEngineering,Inc. Attn:MiguelPantoja 218SHStreet,Suite201 Bakersfield,CA93304 PropertyOwner RaulCruz 3508RobinwoodStreet Bakersfield,CA93309 RE:NoticeofDecisionSitePlanReview(ProjectNo.220095)(Ward1) DearMr.Pantoja: Theplansforconstructionofa1,200squarefootmultitenantbuildingat6550LowryStreetanda1,000squarefoot multitenantbuildingat655PanamaLaneinaC2(RegionalCommercialZone)districthavebeenreviewedbytheSite PlanReviewCommitteeanditemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil.Specific itemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyoucanobtaina buildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneedtobeshownonthe finalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouincomplyingwiththeĭźƷǤƭ standards.Eachitemwillnotewhenitistobecompletedandtheyhavebeengroupedbydepartment development sothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision.TheSite PlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfythe itemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyourobtaining abuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspectorwill giveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissueacertificateof occupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelatedenvironmental approvalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/orsubdividerΛͻ!ƦƦƌźĭğƓƷͼ herein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers,agents,employees, departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims,actions,causesofactions ordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicialtribunalsofanykind whatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,includingwithoutlimitationanyCEQA approvaloranyrelateddevelopmentapprovalsorconditionswhetherimposedbytheCity,ornot,exceptfor/źƷǤƭsole activenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedtothis projectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlementsareissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithinthirty (30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosetheattorneyor outsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnotobligatedtouseany lawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly necessarytomeetacondition, approveminorchangestotheoriginalplanwithoutanewapplicationiftheyare mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS ThissiteplanexpiresonAugust2,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued,or wheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompletedwithin5 yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffectivedateforthe rezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheckagainst thecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemustreceivethis request before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest;however, changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjecttoanewsiteplan review,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas criticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airorwaterquality,and willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis availableforreviewatthePlanningDivision. SPR220095Page|2of17 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:August3,2022 Sincerely, LindaMitchell PrincipalPlanner cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220095_6550LowrySt_MultiTenantBldgs\\_spr.docx SPR220095Page|3of17 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.PriortoreviewofimprovementplansbytheCity,thedevelopershallsubmitagradingplanfor theproposedsitetobereviewedandapprovedbytheCityEngineerandBuildingOfficial (BakersfieldMunicipalCodeSection16.44.010).Withthegradingplan,iftheprojectissubjectto theprovisionsoftheNationalPollutantDischargeEliminationSystem(NPDES),aNoticeofIntent (NOI)tocomplywiththetermsoftheGeneralPermittoDischargeStormWaterAssociatedwith ConstructionActivity(WQOrderNo.9908DWQ)mustbefiledwiththeStateWaterResources ControlBoardinSacramentobeforethebeginningofanyconstructionactivity.Compliancewith thegeneralpermitrequiresthataStormWaterPollutionPreventionPlan(SWPPP)beprepared, continuouslycarriedout,andalwaysbeavailableforpublicinspectionduringnormalconstruction hours. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Agradingpermitisrequiredpriortofinalplanapproval.Thedevelopershallsubmitfour(4)copies ofgradingplansandtwo(2)copiesofthepreliminarysoilsreporttotheBuildingDivision.Afinal soilsreportshallalsobesubmittedtotheBuildingDivisionbeforetheycanissueabuildingpermit. Pleasenotethatgradingplansmustbeconsistentwiththefinalbuildingsiteplansandlandscaping plans.BuildingpermitswillnotbeissueduntilthegradingpermitisapprovedbytheBuilding Division,PlanningDivision(HCP),andPublicWorksDepartment. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Showonthefinalbuildingplanpedestrianaccessfromthepublicwayandaccessibleparking. Privatestreetsarenotthepublicway. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. SPR220095Page|4of17 !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Includewithorshowonthefinalbuildingplansinformationnecessarytoverifythattheproject complieswithallaccessibilityrequirementsofTitle24oftheCaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith disabilitiesfrompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, andspacesinaccordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall notbeparalleltovehicularlanesunlessseparatedbycurbsorrailings. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|5of17 B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:LindaMitchell6613263786orLMitchell@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: ProposedSquareParkingRequired UseFootageRatioParking MultitenantBuilding1001,200SF1space/200Sf6spaces SingletenantBuilding200757SF1space/250Sf3spaces MultitenantBuilding3001,000SF1space/200Sf5spaces TotalRequiredParking:14 spaces (Note:10 offstreetand 4 onstreetparkingspaces(atotalof14parkingspaces)areshownonthe proposedsiteplan.Byordinance,compactandtandemspacescannotbecountedtowards meetingminimumparkingrequirements.Forcommercialdevelopmentcontainingamultitenant pad,anychangeinusewhere50percentormoreofthepadrequiresadditionalparkingpursuant toBakersfieldMunicipalSection17.58.110,thePlanningDirectormayrequireparking commensuratewiththenewuse.) Correction:Removethetwo(2)parkingspacesnorthofBuilding300asitconflictswithPublic Worksstandards. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Lightingisrequiredforallparkinglots,exceptresidentiallotswithfourunitsorless(Section 17.58.060.A.).Illuminationshallbeevenlydistributedacrosstheparkingareawithlightfixtures designedandarrangedsothatlightisdirecteddownwardandisreflectedawayfromadjacent propertiesandstreets.Useofglareshieldsorbafflesmayberequiredforglarereductionor controlofbacklight.Nolightpoles,standardsandfixtures,includingbasesorpedestals,shall exceedaheightof40feetabovegrade.However,lightstandardsplacedlessthan50feetfrom residentiallyzonedordesignatedproperty,orfromexistingresidentialdevelopment,shallnot exceedaheightof15feet.Thefinalbuildingplansshallincludeapictureordiagramofthelight fixturesbeingusedandshowhowlightwillbedirectedontotheparkingarea. SPR220095Page|6of17 (Note:Staffcanrequireadditionaladjustmentstoinstalledlightingafteroccupancytoresolve glareorotherlightingproblemsiftheynegativelyaffectadjacentproperties.) !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Becauseparkingand/oraccessisbeingsharedwithadjacentproperties,thedevelopershallfile withthePlanningDivisionbeforeanybuildingpermitsare issuedacopyofarecordedmap, CC&Rs,orotherinstrumentthatensuresthatdriveaisles,parking,andaccessislegallysharedin commonwithadjoiningpropertiesasdepictedonthesiteplanforthelifeoftheproject. Or,submitaparcelmergerapplication.Recordationofthemergershalloccurbeforefinalbuilding orsiteoccupancycanbegranted. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove.) !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Asolidmasonrywallshallbeconstructedadjacenttoresidentiallyzonedand/ordesignated property.Thiswallmustbeshownonthefinalbuildingplansandshallbeconstructedaminimum heightof6feetasmeasuredfromthehighestadjacentfinishedpropertygrade.Iftheparkinglot, includingdriveaisles,deliveryareas,loadingandunloadingareasarewithin10feetof residentiallyzonedproperty,a7footwidelandscapestripthatincludeslandscapingconsistent withChapter17.61shallbeinstalledbetweenthewallandparking/driveareas. Comments:Provideanelevationorcrosssectionofthewalldetails(i.e.,heightfromgrade). !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|7of17 8.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Internal buildingunitaddresseswillbeonlybysuitenumberandwillbetheresponsibilityoftheowneror developer toassigntoeachtenant.PleasecontactthePlanningDivisionat6613263733for furtherinformation. (Note:Itisrecommendedthatyouassignsuitenumbersbeginningwith100,200,300etc.instead ofanalphabeticcharacter.Ifinthefutureatenantspaceweresplit,youwouldthenbeableto assignasuitenumberbetweentheexistingnumbers,whichwouldkeepyoursuitesinnumerical order.Keepinganorderlynumberingsystemwillmakeiteasierforcustomers,emergency personnel,andmaildeliverytofindthebusiness.) !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Businessidentificationsignsare neitherconsiderednorapproved underthisreview(e.g.,wall, monument,pylon,etc.).AseparatesignpermitreviewedbythePlanningandBuildingDivisions andissuedbytheBuildingDivision,isrequiredforallnewsigns,includingfutureuseand constructionsigns. (Note:SignsmustcomplywiththeSignOrdinance;Chapter17.60oftheBakersfieldMunicipal Code.ReviewthisChapteraspartofduediligence.) !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Thefollowingconditionsarerequiredaspartofagradingpermit: a.HabitatConservationfeesshallberequiredforthisprojectandwillbecalculatedbased onthefeeineffectatthetimeweissueanurbandevelopmentpermit(includesgrading planapprovals)asdefinedintheImplementation/ManagementAgreement(Section2.21) fortheMetropolitanBakersfieldHabitatConservationPlan.Uponpaymentofthefee, theapplicantwillreceiveacknowledgmentofcompliancewithMetropolitanBakersfield HabitatConservationPlan(Implementation/ManagementAgreementSection3.1.4).This feeiscurrently$2,145pergrossacres,payabletotheCityofBakersfield(submittothe PlanningDivision).Thisfeemustbepaidbeforeanygradingorothersitedisturbance occurs. FormsandinstructionsareavailableatthePlanningDivisionorontheĭźƷǤƭwebsiteat www.bakersfieldcity.us(gotoDevelopmentServicesDepartment). ThecurrentMetropolitanBakersfieldHabitatConservationPlan(MBHCP)expiresinyear 2023.Projectsmaybeissuedanurbandevelopmentpermit,gradingplanapproval,or buildingpermitandpayfeespriortothe2023expirationdateunderthecurrentMBHCP. AsdeterminedbytheCityofBakersfield,onlyprojectsreadytobeissuedanurban developmentpermit,gradingplanapprovalorbuildingpermitbeforethe2023expiration datewillbeeligibletopayfeesunderthecurrentMBHCP.Earlypaymentorprepayment ofMBHCPfeesshallnotbeallowed.TheabilityoftheCitytoissueurbandevelopment permitsisgovernedbythetermsoftheMBHCP.Urbandevelopmentpermitsissuedafter the2023expirationdatemaybesubjecttoaneworrevisedHabitatConservationPlan,if SPR220095Page|8of17 approved,orberequiredtocomplydirectlywithrequestsoftheU.S.FishandWildlife ServiceandtheCaliforniaDepartmentofFishandWildlife. b.BurrowingOwlNotification:Theburrowingowlisamigratorybirdspeciesprotectedby internationaltreatyundertheMigratoryBirdTreatyAct(MBTA)of1918(16U.S.C.703 711).TheMBTAmakesitunlawfultotake,possess,buy,sell,purchase,orbarterany migratorybirdlistedin50C.F.R.Part10includingfeathersorotherparts,nests,eggs,or products,exceptasallowedbyimplementingregulations(50C.F.R.21).Sections3503, 3503.5,and3800oftheCaliforniaFishandGameCodeprohibitthetaking,possession,or destructionofbirds,theirnestsoreggs.Toavoidviolationoftheprovisionsoftheselaws generallyrequiresthatprojectrelateddisturbanceatactivenestingterritoriesbereduced oreliminatedduringcriticalphasesofthenestingcycle(March1August15,annually). Disturbancethatcausesnestabandonmentand/orlossofreproductiveeffort(e.g.,killing orabandonmentofeggsoryoung)maybeconsideredͻƷğƉźƓŭͼandispotentially punishablebyfinesand/orimprisonment. c.Priortogrounddisturbance,thedevelopershallhaveaCaliforniaDepartmentofFishand WildlifeapprovedMBHCPbiologistsurveythelocationforkitfox,andcomplywiththe provisionsoftheMetropolitanBakersfieldHabitatConservationPlan.Surveyprotocol shallberecommendedbytheCaliforniaDepartmentofFishandWildlife.Developershall besubjecttothemitigationmeasuresrecommendedbythebiologist.Copiesofthe surveyshallbeprovidedtotheDevelopmentServicesDepartment,CaliforniaDepartment ofFishandWildlife,andtheU.S.FishandWildlifeServicepriortogrounddisturbance. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Rooftopareasofcommercialbuildings(e.g.,office,retail,restaurant,assembly,hotel,hospital, church,school),andindustrialbuildingsadjacenttoresidentiallyzonedproperties,shallbe completelyscreenedbyparapetsorotherfinishedarchitecturalfeaturesconstructedtoaheight ofthehighestequipment,unfinishedstructuralelementorunfinishedarchitecturalfeatureofthe building. !tt\[L/!b{RESPONSE:__________________________________________________________ 12.Openstorageofmaterialsandequipmentshallbesurroundedandscreenedwithasolidwallor fence(screeningalsoappliestogates).Thisfenceshallbeatleast6feetinheightandmaterials shallnotbestackedabovetheheightofthefence. (Note:Fencestallerthan6feetareallowedincommercialandindustrialzonesbuttheywill requireabuildingpermit.) !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|9of17 13.Areasusedforoutsidestorageshallbetreatedwithapermanentdustbinderorotherpermanent dustcontrolmeasureconsistentwiththeregulationsoftheSanJoaquinValleyAirPollution ControlDistrict. (Note:Allpassengervehicleparkingareasmustbepaved.) !tt\[L/!b{RESPONSE:__________________________________________________________ 14.Storageofmaterialsandmerchandiseisprohibitedunlessscreenedinaccordancewiththe municipalcode.Salesofmerchandiseshallnotbepermittedinanyrequiredparkingarea.Sales ofmerchandiseshallbeconductedand/orcontainedwithinanenclosedbuildingorwithina screenedareadedicatedforsuchuse. (Note:Thisdoesnotincludeoutdoorseatingareasforrestaurants.) !tt\[L/!b{RESPONSE:__________________________________________________________ 15.Refusecollectionbinenclosuresandcontainerareasaresubjecttoallrequiredstructuralsetback fromstreetfrontages,andshallnotreduceanyparking,loadingorlandscapingareasasrequired bytheZoningOrdinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 16.Intheeventapreviouslyundocumentedoil/gaswellisuncoveredordiscoveredontheproject, thedeveloperisresponsibletocontacttheCaliforniaGeologicEnergyManagementDivision (CalGEM).Thedeveloperisresponsibleforanyremedialoperationsonthewellrequiredby CalGEM.ThedevelopershallalsobesubjecttoprovisionsofBMCSection15.66.080.B. !tt\[L/!b{RESPONSE:__________________________________________________________ 17.ThedevelopershallmeetallregulationsoftheSanJoaquinValleyAirPollutionControlDistrict (RegulationVIII)concerningdustsuppressionduringconstructionoftheproject.Methods include,butarenotlimitedto;useofwaterorchemicalstabilizer/suppressantstocontroldust emissionfromdisturbedarea,stockpiles,andaccessways;coveringorwettingmaterialsthatare transportedoffsite;limitconstructionrelatedspeedto15mphonallunpavedareas/washingof constructionvehiclesbeforetheyenterpublicstreetstominimizecarryout/trackout;andcease gradingandearthmovingduringperiodsofhighwinds(20mphormore). !tt\[L/!b{RESPONSE:__________________________________________________________ 18.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|10of17 C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.Includeflowdata ƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). i. Showthedistancetothenearesthydrant. ii. Showthedistancefromthathydranttothefarthestpointoftheprojectsite alongthepathoftravel. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Theminimumgatewidthshallbe20feetandaminimumverticalclearanceofthirteen(13)feet six(6)inchesisrequiredwhenthegateisatfullopenposition.Wherethereismorethanone gateandtwoormoredrivewaysseparatedbyislands,aminimumhorizontalclearanceoffifteen (15)feetforeachdrivewayandaminimumverticalclearanceofthirteen(13)feetsix(6)inchesis requiredwhengatesareatfullopenposition.Horizontaldistanceshallbemeasured perpendiculartothedirectionoftravelonthedriveway.Verticaldistanceshallbemeasuredfrom thehighestelevationofthedrivewaytothelowestoverheadobstruction. Comment:Willtherebegatesattheentrances? !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Electricgatesshallbeequippedwithameansofopeningthegatebyfiredepartmentpersonnel foremergencyaccess.Emergencyopeningdevicesshallbeapprovedbythefirecodeofficial.All newconstructionofaccessgatesshallbeequippedwithanautomaticopeningdevicewhichis activatedthroughthewirelessactivationsystemutilizedonCityofBakersfieldownedvehiclesfor trafficpreemption.Installationandmaintenanceofthewirelessactivationsystemonaccess gate(s)shallbecompletedbythegateowner.Thegateopeningdeviceshallhaveadisconnect featureformanualoperationofthegatewhenthepowerfails. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|11of17 D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.PropertyislocatedoutsideoftheCityofBakersfielddomesticwaterservicearea,therefore,only pipelinesandappurtenancesrelatedtofirewateraresubjecttoreview. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Ifthepropertyrequiresadedicatedfirewaterserviceline,Developershallsubmittwo(2)setsof utilityplanssignedbyaCaliforniaRegisteredCivilEngineertotheWaterResourcesDepartment showingalloffsiteandonsiteimprovements,includingconnectionstotheexistingwatermainand undergroundfirewaterlinesandrelatedapparatuses.Includeanyexistingnearbyonoroffsite hydrantsontheplans.Plansshallbesubmittedalongwithapplicableplancheckfeesandany otherassociatedfeesperthecurrentfeeschedule.PlansshallcomplywithcurrentCityStandards andSpecifications,CaliforniaFireCode,andCityofBakersfieldMunicipalCode.CityStandards andSpecificationsareavailablefordownloadfromthe/źƷǤƭwebsiteat www.bakersfieldcity.us/gov/depts./water_resources. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.DevelopershallpaytherequiredWaterResourcesFireServiceInspectionFeesandsubmitan LƓƭƦĻĭƷźƚƓwĻƨǒĻƭƷCƚƩƒ foranyundergroundfirewaterlinesandtheirapparatusesatleasttwo (2)fullbusinessdaysbeforepermanentconstruction.Theformisavailablefordownloadfrom the/źƷǤƭwebsiteatwww.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Drainageshallbekeptonsite.Anyproposedsumpwithintheprivatedevelopmentshallbe privatelymaintained. !tt\[L/!b{RESPONSE:__________________________________________________________ E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallinstallnewconnection(s)tothepublicsewersystem.Thisconnectionshall beshownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|12of17 3.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Iftheprojectgeneratesindustrialwaste,itshallbesubjecttotherequirementsoftheIndustrial WasteOrdinance.AnindustrialwastepermitmustbeobtainedfromthePublicWorks Departmentbeforeissuanceofthebuildingpermit.Tofindoutwhattypeofwasteisconsidered industrial,pleasecontacttheWastewaterTreatmentSuperintendentat6613263249. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplanorfinalbuildingplan. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. SPR220095Page|13of17 !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Thedevelopershalleitherconstructtheequivalentfullwidthlandscapedmedianislandin PanamaLane alongtheķĻǝĻƌƚƦƒĻƓƷƭfrontageorpaytheirproportionateshare(1/2width)of thetotalcostforthefutureconstructionofthemedian.Medianislandsshallbedesignedbythe firstdevelopmentthatoccursalonganapplicablestreetfrontage.Thatdevelopershalleither constructthefullwidthlandscapedmedianislandorpaythemedianislandfee.Themedianisland feeshallbesatisfiedbyfulfillingoneofthefollowingoptions:(1)Paythestandardfeeof$100 perlinearfoot;or(2)Paythecalculatedfeebaseduponactualcostestimatespreparedbythe ProjectEngineer,whichshallbereviewedandapprovedbytheCityEngineer.Ifthemedianisland isnotconstructedbythefirstdevelopmentalonganapplicablestreetfrontage,thesecond developmentalongthatstreetfrontageshallconstructthefullwidthlandscapedmedianisland. !tt\[L/!b{RESPONSE:__________________________________________________________ 12.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactSubdivisionsat6613263588. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b{RESPONSE:__________________________________________________________ 13.Thedevelopershallinstallafullsizedmanholeineachsewerlineexceptresidentialdevelopment beforeitconnectstothesewermain.Thismanholeistobelocatedwithinthepropertybeing developedandmustbeeasilyaccessiblebyCityworkers. !tt\[L/!b{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplans StandardST4 driveapproach(es).Driveapproachesmustbe centeredondriveaisles.Alldimensionsshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|14of17 2.TheBakersfieldMunicipalCode(Section17.58.050.K.)prohibitsvehiclesfrombackingoutofa parkingspaceintoastreet.Pleaserevisetheparkingdesignonthefinalbuildingplanstoeliminate thesespaces.SeeSection6.8.3.1ΑMinimum40ftrequiredfromflowlinetofirstparkingstall onarterialstreets. (Note:Thisprohibitiondoesnotincludesinglefamilyhomesinresidentialzones,ormultiple familyunitsonlocalstreetswheretheTrafficEngineerhasdeterminedthatbackingontoastreet willnotadverselyaffecttrafficandissimilartoasinglefamilyresidentialdrivewayuse.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.ThedevelopershalldedicateanysidewalkextendingoutoftherightofwaytotheCityof Bakersfieldforthepedestrianwayalongallarterialstreets.Thismustbeconductedwitha separateinstrumentorfinalmap. !tt\[L/!b{RESPONSE:__________________________________________________________ G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshallbedesigned accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. Beforeoccupancyofthebuildingorsiteisallowed,3,3 cubicyardfrontloadingtype refuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). ____________8'deepx15'wide(3bins) ____________8'deepx20'wide(4bins) ____________8'deepx10'wide;onskidsfordirectstabonly(16yardrecyclingbin) (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifbothrefuse andrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamustbe SPR220095Page|15of17 expandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabovefor theappropriateenclosuresize.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Facilitiesthatrequiregreasecontainmentmustprovideastoragelocationthatisseparatefrom therefusebinlocation.Thisshallbeshownonthefinalbuildingplans.Ifagreaseinterceptoris tobeusedinsteadofagreasecontainmentbin,theplansmuststillshowthelocationofan adequatelysizedenclosureshouldagreasecontainmentbinberequiredatafuturedate.The greasecontainmentbinshallnotsharethesameenclosureastherefuse/recyclable/organicbin enclosure. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorageto gowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecomean SPR220095Page|16of17 issue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCitypriortoconstruction. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220095Page|17of17