HomeMy WebLinkAbout655 Panama Lane (3) SENTVIAUSMAILANDELECTRONICMAIL August3,2022 Applicant BHTEngineering,Inc. Attn:MiguelPantoja 218SHStreet,Suite201 Bakersfield,CA93304 PropertyOwner RaulCruz 3508RobinwoodStreet Bakersfield,CA93309 RE:NoticeofDecisionSitePlanReview(ProjectNo.220095)(Ward1) DearMr.Pantoja: Theplansforconstructionofa1,200squarefootmultitenantbuildingat6550LowryStreetanda1,000squarefoot multitenantbuildingat655PanamaLaneinaC2(RegionalCommercialZone)districthavebeenreviewedbytheSite PlanReviewCommitteeanditemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil.Specific itemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyoucanobtaina buildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneedtobeshownonthe finalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouincomplyingwiththeĭźƷǤ͸ƭ standards.Eachitemwillnotewhenitistobecompletedandtheyhavebeengroupedbydepartment development sothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision.TheSite PlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfythe itemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyourobtaining abuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspectorwill giveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissueacertificateof occupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelatedenvironmental approvalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/orsubdividerΛͻ!ƦƦƌźĭğƓƷͼ herein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers,agents,employees, departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims,actions,causesofactions ordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicialtribunalsofanykind whatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,includingwithoutlimitationanyCEQA approvaloranyrelateddevelopmentapprovalsorconditionswhetherimposedbytheCity,ornot,exceptfor/źƷǤ͸ƭsole activenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedtothis projectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlementsareissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithinthirty (30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosetheattorneyor outsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnotobligatedtouseany lawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly necessarytomeetacondition, approveminorchangestotheoriginalplanwithoutanewapplicationiftheyare mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS ThissiteplanexpiresonAugust2,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued,or wheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompletedwithin5 yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffectivedateforthe rezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheckagainst thecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemustreceivethis request before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest;however, changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjecttoanewsiteplan review,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas criticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airorwaterquality,and willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis availableforreviewatthePlanningDivision. SPR220095Page|2of17 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩ͸ƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:August3,2022 Sincerely, LindaMitchell PrincipalPlanner cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220095_6550LowrySt_MultiTenantBldgs\\_spr.docx SPR220095Page|3of17 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤ͸ƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b͸{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.PriortoreviewofimprovementplansbytheCity,thedevelopershallsubmitagradingplanfor theproposedsitetobereviewedandapprovedbytheCityEngineerandBuildingOfficial (BakersfieldMunicipalCodeSection16.44.010).Withthegradingplan,iftheprojectissubjectto theprovisionsoftheNationalPollutantDischargeEliminationSystem(NPDES),aNoticeofIntent (NOI)tocomplywiththetermsoftheGeneralPermittoDischargeStormWaterAssociatedwith ConstructionActivity(WQOrderNo.9908DWQ)mustbefiledwiththeStateWaterResources ControlBoardinSacramentobeforethebeginningofanyconstructionactivity.Compliancewith thegeneralpermitrequiresthataStormWaterPollutionPreventionPlan(SWPPP)beprepared, continuouslycarriedout,andalwaysbeavailableforpublicinspectionduringnormalconstruction hours. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Agradingpermitisrequiredpriortofinalplanapproval.Thedevelopershallsubmitfour(4)copies ofgradingplansandtwo(2)copiesofthepreliminarysoilsreporttotheBuildingDivision.Afinal soilsreportshallalsobesubmittedtotheBuildingDivisionbeforetheycanissueabuildingpermit. Pleasenotethatgradingplansmustbeconsistentwiththefinalbuildingsiteplansandlandscaping plans.BuildingpermitswillnotbeissueduntilthegradingpermitisapprovedbytheBuilding Division,PlanningDivision(HCP),andPublicWorksDepartment. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Showonthefinalbuildingplanpedestrianaccessfromthepublicwayandaccessibleparking. Privatestreetsarenotthepublicway. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. SPR220095Page|4of17 !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Includewithorshowonthefinalbuildingplansinformationnecessarytoverifythattheproject complieswithallaccessibilityrequirementsofTitle24oftheCaliforniaBuildingCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith disabilitiesfrompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, andspacesinaccordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall notbeparalleltovehicularlanesunlessseparatedbycurbsorrailings. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 10.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|5of17 B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:LindaMitchell6613263786orLMitchell@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: ProposedSquareParkingRequired UseFootageRatioParking MultitenantBuilding1001,200SF1space/200Sf6spaces SingletenantBuilding200757SF1space/250Sf3spaces MultitenantBuilding3001,000SF1space/200Sf5spaces TotalRequiredParking:14 spaces (Note:10 offstreetand 4 onstreetparkingspaces(atotalof14parkingspaces)areshownonthe proposedsiteplan.Byordinance,compactandtandemspacescannotbecountedtowards meetingminimumparkingrequirements.Forcommercialdevelopmentcontainingamultitenant pad,anychangeinusewhere50percentormoreofthepadrequiresadditionalparkingpursuant toBakersfieldMunicipalSection17.58.110,thePlanningDirectormayrequireparking commensuratewiththenewuse.) Correction:Removethetwo(2)parkingspacesnorthofBuilding300asitconflictswithPublic Worksstandards. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Lightingisrequiredforallparkinglots,exceptresidentiallotswithfourunitsorless(Section 17.58.060.A.).Illuminationshallbeevenlydistributedacrosstheparkingareawithlightfixtures designedandarrangedsothatlightisdirecteddownwardandisreflectedawayfromadjacent propertiesandstreets.Useofglareshieldsorbafflesmayberequiredforglarereductionor controlofbacklight.Nolightpoles,standardsandfixtures,includingbasesorpedestals,shall exceedaheightof40feetabovegrade.However,lightstandardsplacedlessthan50feetfrom residentiallyzonedordesignatedproperty,orfromexistingresidentialdevelopment,shallnot exceedaheightof15feet.Thefinalbuildingplansshallincludeapictureordiagramofthelight fixturesbeingusedandshowhowlightwillbedirectedontotheparkingarea. SPR220095Page|6of17 (Note:Staffcanrequireadditionaladjustmentstoinstalledlightingafteroccupancytoresolve glareorotherlightingproblemsiftheynegativelyaffectadjacentproperties.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Becauseparkingand/oraccessisbeingsharedwithadjacentproperties,thedevelopershallfile withthePlanningDivisionbeforeanybuildingpermitsare issuedacopyofarecordedmap, CC&Rs,orotherinstrumentthatensuresthatdriveaisles,parking,andaccessislegallysharedin commonwithadjoiningpropertiesasdepictedonthesiteplanforthelifeoftheproject. Or,submitaparcelmergerapplication.Recordationofthemergershalloccurbeforefinalbuilding orsiteoccupancycanbegranted. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.Asolidmasonrywallshallbeconstructedadjacenttoresidentiallyzonedand/ordesignated property.Thiswallmustbeshownonthefinalbuildingplansandshallbeconstructedaminimum heightof6feetasmeasuredfromthehighestadjacentfinishedpropertygrade.Iftheparkinglot, includingdriveaisles,deliveryareas,loadingandunloadingareasarewithin10feetof residentiallyzonedproperty,a7footwidelandscapestripthatincludeslandscapingconsistent withChapter17.61shallbeinstalledbetweenthewallandparking/driveareas. Comments:Provideanelevationorcrosssectionofthewalldetails(i.e.,heightfromgrade). !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|7of17 8.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Internal buildingunitaddresseswillbeonlybysuitenumberandwillbetheresponsibilityoftheowneror developer toassigntoeachtenant.PleasecontactthePlanningDivisionat6613263733for furtherinformation. (Note:Itisrecommendedthatyouassignsuitenumbersbeginningwith100,200,300etc.instead ofanalphabeticcharacter.Ifinthefutureatenantspaceweresplit,youwouldthenbeableto assignasuitenumberbetweentheexistingnumbers,whichwouldkeepyoursuitesinnumerical order.Keepinganorderlynumberingsystemwillmakeiteasierforcustomers,emergency personnel,andmaildeliverytofindthebusiness.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.Businessidentificationsignsare neitherconsiderednorapproved underthisreview(e.g.,wall, monument,pylon,etc.).AseparatesignpermitreviewedbythePlanningandBuildingDivisions andissuedbytheBuildingDivision,isrequiredforallnewsigns,includingfutureuseand constructionsigns. (Note:SignsmustcomplywiththeSignOrdinance;Chapter17.60oftheBakersfieldMunicipal Code.ReviewthisChapteraspartofduediligence.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 10.Thefollowingconditionsarerequiredaspartofagradingpermit: a.HabitatConservationfeesshallberequiredforthisprojectandwillbecalculatedbased onthefeeineffectatthetimeweissueanurbandevelopmentpermit(includesgrading planapprovals)asdefinedintheImplementation/ManagementAgreement(Section2.21) fortheMetropolitanBakersfieldHabitatConservationPlan.Uponpaymentofthefee, theapplicantwillreceiveacknowledgmentofcompliancewithMetropolitanBakersfield HabitatConservationPlan(Implementation/ManagementAgreementSection3.1.4).This feeiscurrently$2,145pergrossacres,payabletotheCityofBakersfield(submittothe PlanningDivision).Thisfeemustbepaidbeforeanygradingorothersitedisturbance occurs. FormsandinstructionsareavailableatthePlanningDivisionorontheĭźƷǤ͸ƭwebsiteat www.bakersfieldcity.us(gotoDevelopmentServicesDepartment). ThecurrentMetropolitanBakersfieldHabitatConservationPlan(MBHCP)expiresinyear 2023.Projectsmaybeissuedanurbandevelopmentpermit,gradingplanapproval,or buildingpermitandpayfeespriortothe2023expirationdateunderthecurrentMBHCP. AsdeterminedbytheCityofBakersfield,onlyprojectsreadytobeissuedanurban developmentpermit,gradingplanapprovalorbuildingpermitbeforethe2023expiration datewillbeeligibletopayfeesunderthecurrentMBHCP.Earlypaymentorprepayment ofMBHCPfeesshallnotbeallowed.TheabilityoftheCitytoissueurbandevelopment permitsisgovernedbythetermsoftheMBHCP.Urbandevelopmentpermitsissuedafter the2023expirationdatemaybesubjecttoaneworrevisedHabitatConservationPlan,if SPR220095Page|8of17 approved,orberequiredtocomplydirectlywithrequestsoftheU.S.FishandWildlife ServiceandtheCaliforniaDepartmentofFishandWildlife. b.BurrowingOwlNotification:Theburrowingowlisamigratorybirdspeciesprotectedby internationaltreatyundertheMigratoryBirdTreatyAct(MBTA)of1918(16U.S.C.703 711).TheMBTAmakesitunlawfultotake,possess,buy,sell,purchase,orbarterany migratorybirdlistedin50C.F.R.Part10includingfeathersorotherparts,nests,eggs,or products,exceptasallowedbyimplementingregulations(50C.F.R.21).Sections3503, 3503.5,and3800oftheCaliforniaFishandGameCodeprohibitthetaking,possession,or destructionofbirds,theirnestsoreggs.Toavoidviolationoftheprovisionsoftheselaws generallyrequiresthatprojectrelateddisturbanceatactivenestingterritoriesbereduced oreliminatedduringcriticalphasesofthenestingcycle(March1August15,annually). Disturbancethatcausesnestabandonmentand/orlossofreproductiveeffort(e.g.,killing orabandonmentofeggsoryoung)maybeconsideredͻƷğƉźƓŭͼandispotentially punishablebyfinesand/orimprisonment. c.Priortogrounddisturbance,thedevelopershallhaveaCaliforniaDepartmentofFishand WildlifeapprovedMBHCPbiologistsurveythelocationforkitfox,andcomplywiththe provisionsoftheMetropolitanBakersfieldHabitatConservationPlan.Surveyprotocol shallberecommendedbytheCaliforniaDepartmentofFishandWildlife.Developershall besubjecttothemitigationmeasuresrecommendedbythebiologist.Copiesofthe surveyshallbeprovidedtotheDevelopmentServicesDepartment,CaliforniaDepartment ofFishandWildlife,andtheU.S.FishandWildlifeServicepriortogrounddisturbance. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 11.Rooftopareasofcommercialbuildings(e.g.,office,retail,restaurant,assembly,hotel,hospital, church,school),andindustrialbuildingsadjacenttoresidentiallyzonedproperties,shallbe completelyscreenedbyparapetsorotherfinishedarchitecturalfeaturesconstructedtoaheight ofthehighestequipment,unfinishedstructuralelementorunfinishedarchitecturalfeatureofthe building. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 12.Openstorageofmaterialsandequipmentshallbesurroundedandscreenedwithasolidwallor fence(screeningalsoappliestogates).Thisfenceshallbeatleast6feetinheightandmaterials shallnotbestackedabovetheheightofthefence. (Note:Fencestallerthan6feetareallowedincommercialandindustrialzonesbuttheywill requireabuildingpermit.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|9of17 13.Areasusedforoutsidestorageshallbetreatedwithapermanentdustbinderorotherpermanent dustcontrolmeasureconsistentwiththeregulationsoftheSanJoaquinValleyAirPollution ControlDistrict. (Note:Allpassengervehicleparkingareasmustbepaved.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 14.Storageofmaterialsandmerchandiseisprohibitedunlessscreenedinaccordancewiththe municipalcode.Salesofmerchandiseshallnotbepermittedinanyrequiredparkingarea.Sales ofmerchandiseshallbeconductedand/orcontainedwithinanenclosedbuildingorwithina screenedareadedicatedforsuchuse. (Note:Thisdoesnotincludeoutdoorseatingareasforrestaurants.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 15.Refusecollectionbinenclosuresandcontainerareasaresubjecttoallrequiredstructuralsetback fromstreetfrontages,andshallnotreduceanyparking,loadingorlandscapingareasasrequired bytheZoningOrdinance. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 16.Intheeventapreviouslyundocumentedoil/gaswellisuncoveredordiscoveredontheproject, thedeveloperisresponsibletocontacttheCaliforniaGeologicEnergyManagementDivision (CalGEM).Thedeveloperisresponsibleforanyremedialoperationsonthewellrequiredby CalGEM.ThedevelopershallalsobesubjecttoprovisionsofBMCSection15.66.080.B. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 17.ThedevelopershallmeetallregulationsoftheSanJoaquinValleyAirPollutionControlDistrict (RegulationVIII)concerningdustsuppressionduringconstructionoftheproject.Methods include,butarenotlimitedto;useofwaterorchemicalstabilizer/suppressantstocontroldust emissionfromdisturbedarea,stockpiles,andaccessways;coveringorwettingmaterialsthatare transportedoffsite;limitconstructionrelatedspeedto15mphonallunpavedareas/washingof constructionvehiclesbeforetheyenterpublicstreetstominimizecarryout/trackout;andcease gradingandearthmovingduringperiodsofhighwinds(20mphormore). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 18.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|10of17 C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.Includeflowdata ƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). i. Showthedistancetothenearesthydrant. ii. Showthedistancefromthathydranttothefarthestpointoftheprojectsite alongthepathoftravel. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Theminimumgatewidthshallbe20feetandaminimumverticalclearanceofthirteen(13)feet six(6)inchesisrequiredwhenthegateisatfullopenposition.Wherethereismorethanone gateandtwoormoredrivewaysseparatedbyislands,aminimumhorizontalclearanceoffifteen (15)feetforeachdrivewayandaminimumverticalclearanceofthirteen(13)feetsix(6)inchesis requiredwhengatesareatfullopenposition.Horizontaldistanceshallbemeasured perpendiculartothedirectionoftravelonthedriveway.Verticaldistanceshallbemeasuredfrom thehighestelevationofthedrivewaytothelowestoverheadobstruction. Comment:Willtherebegatesattheentrances? !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Electricgatesshallbeequippedwithameansofopeningthegatebyfiredepartmentpersonnel foremergencyaccess.Emergencyopeningdevicesshallbeapprovedbythefirecodeofficial.All newconstructionofaccessgatesshallbeequippedwithanautomaticopeningdevicewhichis activatedthroughthewirelessactivationsystemutilizedonCityofBakersfieldownedvehiclesfor trafficpreemption.Installationandmaintenanceofthewirelessactivationsystemonaccess gate(s)shallbecompletedbythegateowner.Thegateopeningdeviceshallhaveadisconnect featureformanualoperationofthegatewhenthepowerfails. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|11of17 D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.PropertyislocatedoutsideoftheCityofBakersfielddomesticwaterservicearea,therefore,only pipelinesandappurtenancesrelatedtofirewateraresubjecttoreview. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Ifthepropertyrequiresadedicatedfirewaterserviceline,Developershallsubmittwo(2)setsof utilityplanssignedbyaCaliforniaRegisteredCivilEngineertotheWaterResourcesDepartment showingalloffsiteandonsiteimprovements,includingconnectionstotheexistingwatermainand undergroundfirewaterlinesandrelatedapparatuses.Includeanyexistingnearbyonoroffsite hydrantsontheplans.Plansshallbesubmittedalongwithapplicableplancheckfeesandany otherassociatedfeesperthecurrentfeeschedule.PlansshallcomplywithcurrentCityStandards andSpecifications,CaliforniaFireCode,andCityofBakersfieldMunicipalCode.CityStandards andSpecificationsareavailablefordownloadfromthe/źƷǤ͸ƭwebsiteat www.bakersfieldcity.us/gov/depts./water_resources. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.DevelopershallpaytherequiredWaterResourcesFireServiceInspectionFeesandsubmitan LƓƭƦĻĭƷźƚƓwĻƨǒĻƭƷCƚƩƒ foranyundergroundfirewaterlinesandtheirapparatusesatleasttwo (2)fullbusinessdaysbeforepermanentconstruction.Theformisavailablefordownloadfrom the/źƷǤ͸ƭwebsiteatwww.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Drainageshallbekeptonsite.Anyproposedsumpwithintheprivatedevelopmentshallbe privatelymaintained. !tt\[L/!b͸{RESPONSE:__________________________________________________________ E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallinstallnewconnection(s)tothepublicsewersystem.Thisconnectionshall beshownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|12of17 3.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Iftheprojectgeneratesindustrialwaste,itshallbesubjecttotherequirementsoftheIndustrial WasteOrdinance.AnindustrialwastepermitmustbeobtainedfromthePublicWorks Departmentbeforeissuanceofthebuildingpermit.Tofindoutwhattypeofwasteisconsidered industrial,pleasecontacttheWastewaterTreatmentSuperintendentat6613263249. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplanorfinalbuildingplan. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. SPR220095Page|13of17 !tt\[L/!b͸{RESPONSE:__________________________________________________________ 10.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 11.Thedevelopershalleitherconstructtheequivalentfullwidthlandscapedmedianislandin PanamaLane alongtheķĻǝĻƌƚƦƒĻƓƷ͸ƭfrontageorpaytheirproportionateshare(1/2width)of thetotalcostforthefutureconstructionofthemedian.Medianislandsshallbedesignedbythe firstdevelopmentthatoccursalonganapplicablestreetfrontage.Thatdevelopershalleither constructthefullwidthlandscapedmedianislandorpaythemedianislandfee.Themedianisland feeshallbesatisfiedbyfulfillingoneofthefollowingoptions:(1)Paythestandardfeeof$100 perlinearfoot;or(2)Paythecalculatedfeebaseduponactualcostestimatespreparedbythe ProjectEngineer,whichshallbereviewedandapprovedbytheCityEngineer.Ifthemedianisland isnotconstructedbythefirstdevelopmentalonganapplicablestreetfrontage,thesecond developmentalongthatstreetfrontageshallconstructthefullwidthlandscapedmedianisland. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 12.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactSubdivisionsat6613263588. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 13.Thedevelopershallinstallafullsizedmanholeineachsewerlineexceptresidentialdevelopment beforeitconnectstothesewermain.Thismanholeistobelocatedwithinthepropertybeing developedandmustbeeasilyaccessiblebyCityworkers. !tt\[L/!b͸{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplans StandardST4 driveapproach(es).Driveapproachesmustbe centeredondriveaisles.Alldimensionsshallbeshownonthefinalbuildingplans. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|14of17 2.TheBakersfieldMunicipalCode(Section17.58.050.K.)prohibitsvehiclesfrombackingoutofa parkingspaceintoastreet.Pleaserevisetheparkingdesignonthefinalbuildingplanstoeliminate thesespaces.SeeSection6.8.3.1ΑMinimum40ftrequiredfromflowlinetofirstparkingstall onarterialstreets. (Note:Thisprohibitiondoesnotincludesinglefamilyhomesinresidentialzones,ormultiple familyunitsonlocalstreetswheretheTrafficEngineerhasdeterminedthatbackingontoastreet willnotadverselyaffecttrafficandissimilartoasinglefamilyresidentialdrivewayuse.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.ThedevelopershalldedicateanysidewalkextendingoutoftherightofwaytotheCityof Bakersfieldforthepedestrianwayalongallarterialstreets.Thismustbeconductedwitha separateinstrumentorfinalmap. !tt\[L/!b͸{RESPONSE:__________________________________________________________ G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshallbedesigned accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. Beforeoccupancyofthebuildingorsiteisallowed,3,3 cubicyardfrontloadingtype refuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). ____________8'deepx15'wide(3bins) ____________8'deepx20'wide(4bins) ____________8'deepx10'wide;onskidsfordirectstabonly(16yardrecyclingbin) (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifbothrefuse andrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamustbe SPR220095Page|15of17 expandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabovefor theappropriateenclosuresize.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Facilitiesthatrequiregreasecontainmentmustprovideastoragelocationthatisseparatefrom therefusebinlocation.Thisshallbeshownonthefinalbuildingplans.Ifagreaseinterceptoris tobeusedinsteadofagreasecontainmentbin,theplansmuststillshowthelocationofan adequatelysizedenclosureshouldagreasecontainmentbinberequiredatafuturedate.The greasecontainmentbinshallnotsharethesameenclosureastherefuse/recyclable/organicbin enclosure. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorageto gowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecomean SPR220095Page|16of17 issue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCitypriortoconstruction. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 10.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220095Page|17of17