Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1012 Bradshaw Street
SENTVIAUSMAILANDELECTRONICMAIL August22,2022 Applicant RobertoPerez 3715SycamoreCreekDrive Bakersfield,CA93313 PropertyOwner DannyRio 1012BradshawStreet Bakersfield,CA93307 RE:NoticeofDecisionSitePlanReview(ProjectNo.220210)(Ward1) DearMr.Perez: Theplansforaconversionofan836squarefootdetachedaccessorystructureintoadwellingunitand conversionofa482squarefootgroundfloorofadetached2storystructureintoadwelling(foratotalof4unit onthepremise)inanR2(LimitedMultipleFamilyZone)districtlocatedat1012BradshawStreethavebeen reviewedbytheSitePlanReviewCommitteeanditemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil. Specificitemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyou canobtainabuildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneed tobeshownonthefinalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouin complyingwiththeĭźƷǤƭdevelopmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhave beengroupedbydepartmentsothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision. TheSitePlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyou satisfytheitemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmay delayyourobtainingabuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspect thedevelopmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyou havesatisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,thearea inspectorwillgiveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcan issueacertificateofoccupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissueda certificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelated environmentalapprovalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/or subdividerΛͻ!ƦƦƌźĭğƓƷͼherein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers, agents,employees,departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims, actions,causesofactionsordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicial tribunalsofanykindwhatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,including withoutlimitationanyCEQAapprovaloranyrelateddevelopmentapprovalsorconditionswhetherimposedbythe City,ornot,exceptfor/źƷǤƭsoleactivenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedtothis projectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlementsareissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithin thirty(30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosetheattorney oroutsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnotobligatedtouse anylawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcan onlyapproveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessarytomeetacondition, mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS Thissiteplanexpireson August21,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeen issued,orwheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbe completedwithin5yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupon theeffectivedatefortherezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheck againstthecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemust receivethisrequest before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextension request;however,changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbe subjecttoanewsiteplanreview,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoning Ordinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQuality Act(CEQA)accordingtoSection15303.ThisprojectisexemptbecauseitisaClass3projectconsistingofthe conversionofexistingsmallstructuresfromoneusetoanotherwhereonlyminormodificationsaremadeinthe exteriorofthestructure.ANoticeofExemptionhasbeenpreparedandisavailableforreviewatthePlanning Division. SPR220210Page|2of12 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein cisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiled writingstatingthepre within 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanning Director,1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingon theappealandtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrors oromissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestions aboutanyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactperson representingthedepartmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itisthe propertyƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveother questionsregardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivision at(661)3263733. DECISIONDATE:August22,2022 Sincerely, LindaMitchell PrincipalPlanner cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220210_1012BradshawStreet_ADU\\sprltr.docx SPR220210Page|3of12 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbe allowedoccupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlement approvals(thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuilding plans,alertyoutospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopment standards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforea buildingpermitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponseby usingthe!tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactΑShannonClark;sclark@bakersfieldcity.us) 1.Showonthefinalbuildingplanhowandwherewaterwillbedrainedfromtheproperty. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602ofthe CaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontactthe applicablewaterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthe developmentassoonaspossible.Todeterminewhothewaterpurveyorforthedevelopment is,youmaycontacttheCityofBakersfieldWaterResourcesDepartment(1000BuenaVista Road,Bakersfield,CA,phone:6613263715). !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220210Page|4of12 B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:LindaMitchell6613263786orLMitchell@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: Existing/ProposedUnit/SquareParkingRequired UsesFootageRatioParking Existingdwellingunits2Priorto1954:00 constructedin1940s Proposeddwellingunits22spacesperdwellingunit4 TotalRequiredParking:4spaces (Note:0parkingspacesareshownontheproposedsiteplanbutthereisaproposeddetached garage.Byordinance,compactandtandemspacescannotbecountedtowardsmeeting minimumparkingrequirements.) a. Showandidentifythefour(4)requiredparkingspacesforthetwo(2)additionaldwelling units. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesare maintained,andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmitted totheBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhas approvedthefinallandscapeplanforconsistencywithapprovedsiteplansandminimum ordinancestandards.PleaserefertothelandscapingrequirementsinChapter17.61. Landscapeplansshallinclude,butarenotlimitedto,dataon:gallon/boxsize,spacing,species (referenceapprovedparkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations, groundcovercalculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) SPR220210Page|5of12 (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove. b. Providethedetailsoftheproposedtreesand/orshrubs(i.e.,species,botanicalname,size). c. Addthefollowingnotestothesiteplan: ͻ Shrubsand/orgroundcover,includingturf,shallcovernolessthanseventyfivepercentof therequiredlandscapedareawithinfouryearsofplanting.ͼ d. ReviseaccordinglyforcompliancewithSection17.61.030.Fasfollows. Along streetfrontages,atreeshallbeplantedataratioofonetreepertwentylinealfeet, orportionthereof.Treesmaybeclusteredorgroupedtonotconflictwithrequiredfirelanes, publicentrances/exits,utilityeasements,and signs providedtheminimumtreetofrontage ratioissatisfied.Aspeciesmixofthirtypercentevergreenandseventypercentdeciduous shallbemaintained. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Ourrecordsshowthattheprojectiscontainedonmorethanoneparcel.Becausebuilding setbackscannotbemetbasedonthedesignlayout,aparcellinebisectsabuilding,and/or parkingforresidentialuseisnotonthesamesiteastheproject(Section17.58.020.B.ofthe BakersfieldMunicipalCode),aparcelmergerorlotlineadjustmentapplicationremovingor relocatingpropertylinesshallbesubmittedtothePlanningDivisionbeforebuildingpermitscan beissued.Recordationofthemapshalloccurbeforefinalbuildingorsiteoccupancycanbe granted.Ifourrecordsareinerror,pleaseprovideacopyoftheparcelmap,subdivisionmap,or certificateofcomplianceshowingtheapprovedpropertylines. (Note:An!ƭƭĻƭƭƚƩƭmapisnotacceptablesinceitisonlyfortaxpurposesanddoesnotverify legalparcelstatus.) a. Thiswillberequiredfortheproposedadditiontothemainhome.Inaddition,ifthe proposeddetachedgaragewillbeusedfortherequiredparkingspacesfortheadditional dwellingunits,thenaparcelmergerisrequired. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Internal buildingunitaddresseswillbeonlybysuitenumberandwillbetheresponsibilityoftheowner ordevelopertoassigntoeachtenant.PleasecontactKarlDavissonat6613263594forfurther information. SPR220210Page|6of12 (Note:Itisrecommendedthatyouassignsuitenumbersbeginningwith100,200,300etc. insteadofanalphabeticcharacter.Ifinthefutureatenantspaceweresplit,youwouldthenbe abletoassignasuitenumberbetweentheexistingnumbers,whichwouldkeepyoursuitesin numerical order.Keepinganorderlynumberingsystemwillmakeiteasierforcustomers, emergencypersonnel,andmaildeliverytofindthebusiness.) !tt\[L/!b{RESPONSE:__________________________________________________________ 7.AParkDevelopmentandImprovementFeeshallbepaidatthetimeofthebuildingpermitbeing issuedforeachindependentresidentialunit.Wewillbasethefeeattherateineffectatthe timethepermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Refusecollectionbinenclosuresandcontainerareasaresubjecttoallrequiredstructural setbackfromstreetfrontages,andshallnotreduceanyparking,loadingorlandscapingareasas requiredbytheZoningOrdinance. a. Showandidentifythelocationoftherefusecollectionbins. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lighting andotherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditems havebeeninstalled.Anydeviationsfromtheapprovedplanswithoutpriorapprovalfromthe PlanningDivisionmayresultinreconstructionanddelaysinobtainingabuildingorsite occupancy. !tt\[L/!b{RESPONSE:__________________________________________________________ C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.Includeflowdata onall hydrants.Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWater ResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). i. Showdistancetothenearesthydrant. ii. Showdistancefromthenearesthydranttothefarthestpointoftheprojectsite. b.Allfiresprinklerand/orstandpipesystems,firealarmsandcommercialhoodsystems. ThesesuppressionsystemsrequirereviewandpermitsbytheFireDepartment.TheFire SPR220210Page|7of12 Departmentwillissueguidelinesforthesevariousitemsastheymayapplytothis project. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.ThedevelopermustpayrequiredfeestoandrequestaninspectionfromtheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA,phone:6613263715)forany undergroundsprinklerfeedsatleast2fullbusinessdaysbeforetheyareburied.ThePrevention ServicesDivision(2101HStreet,BakersfieldCA,Ph.661/3263979)mustcompleteallonsite inspectionsoffiresprinklersystemsandfirealarmsystemsbeforeanybuildingisoccupied. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Wherefireapparatusaccessroadsorawatersupplyforfireprotectionarerequiredtobe installed,suchprotectionshallbeinstalledandmadeserviceablepriortoandduringthetimeof construction. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b{RESPONSE:__________________________________________________________ D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.Atthistime,therearenoapplicableconditionsfortheproposedproject.Conditionsmaybe addediftheprojectchanges. E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallconstructstandardaccessiblerampsatthe northeast cornerof Cottonwood Road and BradshawStreet accordingtoadoptedcitystandards.Theseimprovementsshallbe shownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allonsiteareasrequiredtobepaved(i.e.,parkinglots,accessdrives,loadingareas,etc.)shall consistofconcrete,asphalticconcrete(TypeB.A.C.)orotherpavedstreetmaterialapprovedby theCityEngineer.Pavementshallbeaminimumthicknessof2inchesover3inchesofapproved basematerial(i.e.,ClassIIA.B.)ifconcreteisused,itshallbeaminimumthicknessof4inches SPR220210Page|8of12 perMunicipalCodeSection17.58.060.A.Thispavingstandardshallbenotedonthefinal buildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspection tofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCity Engineer.Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesite inspectionshallbeshownonthefinalbuildingplan. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbe donewithinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthis siteplanreviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethis feeattherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirst requiredCityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportation ImpactFee(TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimethe applicableapprovalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.The PublicWorksDepartmentwillcalculateanestimateofthetotalfeeuponsubmittalof constructionplansfortheproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Thedevelopershalleitherconstructtheequivalentfullwidthlandscapedmedianislandin CottonwoodRoad alongtheķĻǝĻƌƚƦƒĻƓƷƭfrontageorpaytheirproportionateshare(1/2 width)ofthetotalcostforthefutureconstructionofthemedian.Medianislandsshallbe designedbythefirstdevelopmentthatoccursalonganapplicablestreetfrontage.That developershalleitherconstructthefullwidthlandscapedmedianislandorpaythemedian islandfee.Themedianislandfeeshallbesatisfiedbyfulfillingoneofthefollowingoptions:(1) Paythestandardfeeof$100perlinearfoot;or(2)Paythecalculatedfeebaseduponactualcost estimatespreparedbytheProjectEngineer,whichshallbereviewedandapprovedbytheCity Engineer.Ifthemedianislandisnotconstructedbythefirstdevelopmentalonganapplicable streetfrontage,theseconddevelopmentalongthatstreetfrontageshallconstructthefullwidth landscapedmedianisland. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220210Page|9of12 9.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.If therearequestions,contactSubdivisionsat6613263588. (Note:Ifalreadywithin amaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplans StandardST7 wide(toptotop)driveapproach(es).Drive approachesmustbecenteredondriveaisles.Alldimensionsshallbeshownonthefinalbuilding plans. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Ifapplicable,thedevelopershalldedicateanysidewalkextendingoutoftherightofwaytothe CityofBakersfieldforthepedestrianwayalongallarterialstreets.Thismustbeconductedwith aseparateinstrumentorfinalmap. !tt\[L/!b{RESPONSE:__________________________________________________________ G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentarea fortherefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(see PlanningDivisionconditions).Levelsofservicearebasedonhowoftencollectionoccursas follows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshallbedesigned accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. Beforeoccupancyofthebuildingorsiteisallowed,3,3 cubicyardfrontloadingtype refuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). ____________8'deepx15'wide(3bins) SPR220210Page|10of12 ____________8'deepx20'wide(4bins) ____________8'deepx10'wide;onskidsfordirectstabonly(16yardrecyclingbin) (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifboth refuseandrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamust beexpandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabove fortheappropriateenclosuresize.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Showonthefinalbuildingplans__________________compactorrolloffbinlocation(s), designedaccordingtoadoptedCitystandards(Detail#ST30andST31).Pleasecontactstafffor additionalinformationoncompactorrequirementsandplacement. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Residentialpropertieswithfour(4)unitsorgreaterandarerequiredtohaveADAAccessible unit/s,mustproviderefuse/recyclingenclosuresthatareADAAccessible(Detail#ST29). !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Residentialpropertieswiththree(3)unitsorlesswillbeservicedwithautomatedcarts.Every dwellingunitmusthaveitsowncartandnomorethanthree(3)cartswillbeallowedforeach parcel.AscreenedЌxВconcreterefusecartstoragepadmustbeprovidedforcartswhenthey arenotoutforcollection(thisareashallbeclearlyshownonthefinalbuildingplans).TheSolid WasteDivisionwilldeterminewhereservicecollectionwilloccur(streetcurbsideoralley). !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspace providedforrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilities fromdamage. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. SPR220210Page|11of12 !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorage togowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecome anissue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCity priortoconstruction. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220210Page|12of12