HomeMy WebLinkAboutFMC 2022Appendix VI Underground Storage Tank  Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages Underground Storage Tank  Monitoring System Certification Form Page 2 of 6 5.MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; Monitoring System Set-up Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? Secondary containment systems are free of damage, debris, or liquid? Are the audible and visual alarms operational? All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? The monitoring system set-up was reviewed, and proper settings confirmed? Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) Sump UDC If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) 3 GPH 0.1 GPH 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? For electronic LLDs, does the turbine automatically shut off when a release is detected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Were all items on the equipment manufacturer’s maintenance checklist completed? Were all LLDs confirmed operational within regulatory requirements? LLD ID LLD Model Lines Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING Check this box if tank gauging is used only for inventory control. Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? Was accuracy of system’s product level readings tested? Was accuracy of system’s water level readings tested? Were all probes reinstalled properly? Were all items on the equipment manufacturer’s maintenance checklist completed? Probe ID Probe Model Tanks Monitored Pass Fail 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. Monitoring System Certification UST Monitoring Site Plan Site Address: 6100 District Blvd., Bakersfield, CA. 93313 ffi+a / 6,rNA5t ........,..-. ' ooc' . / l. Y .6.rca f,rr *tar... . .Af(' . Tctribba -.219 . .s! t5ec. :---.'3{:)yl.o - iuq. ,Frll '' *. |l.Jloa.. . -. ge.rylo.- 4?o. Date map was drawn: I I. I[structions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certiflcation. On your site plan, show the general layout of tanls and piping. Clearly identi$ locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank amular spaces, sumps, dispenser pans, spill containers, or other secondary gontairunent areas; mechanical or electronic line leak detectors; and in+ank liquid level probes (ifused for leak detection). In the space provided, note the date dris Site Plan was prepared. Page 4 of 4 $ww.unidocs.orguN-036 - 4/,r Rev. 0l/17l0t 08 22 22 <I20100AUG 22, 2022 8:22 AM 265022 6100 DISTRICT BLVDBAKERSFIELD CA IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 DIESEL 7415 7327 4585 64.95 0.77 86.29 ><I90500AUG 22, 2022 8:22 AMSOFTWARE REVISION LEVELVERSION 421.00SOFTWARE# 346421-100-A CREATED - 00.11.15.13.40 NO SOFTWARE MODULE ><I50201AUG 22, 2022 8:22 AM SHIFT TIME 1 : 12:15 AM ><I50202AUG 22, 2022 8:23 AM SHIFT TIME 2 : DISABLED ><I50203AUG 22, 2022 8:23 AM SHIFT TIME 3 : DISABLED ><I50204AUG 22, 2022 8:23 AM SHIFT TIME 4 : DISABLED ><I54600AUG 22, 2022 8:23 AM TANK PER TST NEEDED WRN: DISABLED ><I54900AUG 22, 2022 8:23 AM TANK ANN TST NEEDED WRN: DISABLED ><9999FF1B><I55600AUG 22, 2022 8:23 AM LINE PER TST NEEDED WRN: DISABLED ><I55900AUG 22, 2022 8:23 AM LINE ANN TST NEEDED WRN: DISABLED ><I51400AUG 22, 2022 8:23 AM H-PROTOCOL DATA FORMATHEIGHT ><I51A01AUG 22, 2022 8:23 AM DAYLIGHT SAVING TIMEENABLED ON ><I51B00AUG 22, 2022 8:23 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 3 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM > <I51600 AUG 22, 2022 8:23 AM RE-DIRECT LOCAL PRINTOUTDISABLED > <I50400 AUG 22, 2022 8:23 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED ><9999FF1B> <9999FF1B><9999FF1B> <I88101 AUG 22, 2022 8:23 AMPORT SETTINGS: COMM BOARD : 1 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITYCODE : DISABLED DTR NORMAL STATE: HIGH >< I88102AUG 22, 2022 8:24 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITYCODE : DISABLED ><I88103AUG 22, 2022 8:24 AM ><I60100AUG 22, 2022 8:24 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL ON 2 OFF 3 OFF 4 OFF ><I60200AUG 22, 2022 8:24 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL 2 3 4 ><I60300AUG 22, 2022 8:24 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL 1 2 2 3 3 4 4><I60900AUG 22, 2022 8:24 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL 0.000450 2 0.000000 3 0.000000 4 0.000000 >< I60700AUG 22, 2022 8:24 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL 109.50 2 0.00 3 0.00 4 0.00 >< I60A00AUG 22, 2022 8:24 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 DIESEL 1 PT 12000 2 1 PT 0 3 1 PT 0 4 1 PT 0 >< I60400AUG 22, 2022 8:24 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 12000 2 0 3 0 4 0 >< I60500AUG 22, 2022 8:24 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 DIESEL 12000 0 0 0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 ><I60600AUG 22, 2022 8:24 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ><9999FF1B><I62F00AUG 22, 2022 8:25 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 DIESEL 4.0 INCHES ><I62700AUG 22, 2022 8:25 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL 5.0> <9999FF1B> <I62400 AUG 22, 2022 8:25 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL 5.0 >< I62800AUG 22, 2022 8:25 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 12000 2 0 3 0 4 0 >< I62300AUG 22, 2022 8:25 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 10800 2 0 3 0 4 0 >< I62200AUG 22, 2022 8:25 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 11400 2 0 3 0 4 0 >< I62900AUG 22, 2022 8:25 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 600 2 0 3 0 4 0><I62100AUG 22, 2022 8:25 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 500 2 0 3 0 4 0><I62600AUG 22, 2022 8:25 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 99 2 99 3 99 4 99><I62500AUG 22, 2022 8:26 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 99 2 99 3 99 4 99><I60800AUG 22, 2022 8:26 AM TANK TILT TANK PRODUCT LABEL INCHES 1 DIESEL 0.00 2 0.00 3 0.00 4 0.00><I60B00 AUG 22, 2022 8:26 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED >< I60C00AUG 22, 2022 8:26 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 DIESEL 0.00 2 0.00 3 0.00 4 0.00> <I61200 AUG 22, 2022 8:26 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL MANIFOLDED TANKS 1 DIESEL NONE 2 NONE 3 NONE 4 NONE> <I63600 AUG 22, 2022 8:26 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 0 3 0 4 0> <I62A00 AUG 22, 2022 8:26 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 0 3 0 4 0> < I62C00AUG 22, 2022 8:26 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 DIESEL STANDARD 2 STANDARD 3 STANDARD 4 STANDARD ><I62D00AUG 22, 2022 8:26 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ><I63100AUG 22, 2022 8:26 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 DIESEL OFF OFF 2 OFF OFF 3 OFF OFF 4 OFF OFF ><I63000AUG 22, 2022 8:26 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 DIESEL OFF 2 OFF 3 OFF 4 OFF > <I63200 AUG 22, 2022 8:27 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 DIESEL OFF 2 OFF 3 OFF 4 OFF >< I61000AUG 22, 2022 8:27 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 DIESEL 5 2 1 3 1 4 1 ><9999FF1B> <I61100 AUG 22, 2022 8:27 AM LEAK TEST METHOD- - - - - - - - - - - - TEST ON DATE : ALL TANKJAN 1, 1996 START TIME : DISABLEDTEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED >< I61300AUG 22, 2022 8:27 AM CSLD PROBABLITY OF DETECTION > < I61400AUG 22, 2022 8:27 AMCSLD CLIMATE FACTOR ><9999FF1B><I61A00AUG 22, 2022 8:27 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 DIESEL DISABLED 2 DISABLED 3 DISABLED 4 DISABLED><I61B00AUG 22, 2022 8:27 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM ><I61C00AUG 22, 2022 8:27 AM CSLD REPORT ONLY ><9999FF1B><9999FF1B><9999FF1B><I70200AUG 22, 2022 8:27 AM LIQUID LABEL DEVICE LABEL 1 ANNULAR 2 DISPENSER 3 SOUTH SUMP 4 NORTH SUMP 5 DISPENSER PAN 6 7 8 > <I70300 AUG 22, 2022 8:27 AM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR TRI-STATE (SINGLE FLOAT) 2 DISPENSER TRI-STATE (SINGLE FLOAT) 3 SOUTH SUMP TRI-STATE (SINGLE FLOAT) 4 NORTH SUMP TRI-STATE (SINGLE FLOAT) 5 DISPENSER PAN TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) >< I70400AUG 22, 2022 8:28 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 ANNULAR ANNULAR SPACE 2 DISPENSER DISPENSER PAN 3 SOUTH SUMP STP SUMP 4 NORTH SUMP STP SUMP 5 DISPENSER PAN DISPENSER PAN 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS > <I80700 AUG 22, 2022 8:28 AM RELAY LABEL DEVICE LABEL 1 REMOTE ALARM 2 POSITIVE SHUTOFF >< I80900AUG 22, 2022 8:28 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 REMOTE ALARM NORMALLY OPEN 2 POSITIVE SHUTOFF NORMALLY OPEN ><I80B00AUG 22, 2022 8:28 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 REMOTE ALARM NONE 2 POSITIVE SHUTOFF NONE ><I80A00AUG 22, 2022 8:28 AM RELAY TYPE RELAY DESIGNATION TYPE 1 REMOTE ALARM STANDARD 2 POSITIVE SHUTOFF STANDARD ><I80800AUG 22, 2022 8:28 AM RELAY SETUP REPORT R 1:REMOTE ALARM TYPE: STANDARDNORMALLY OPEN IN-TANK ALARMS ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:HIGH PRODUCT ALARM ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:WATER ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING R 2:POSITIVE SHUTOFF TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - > <9999FF1B><9999FF1B> <9999FF1B><9999FF1B> <9999FF1B><9999FF1B> <9999FF1B><9999FF1B> <9999FF1B><9999FF1B> <I90200 AUG 22, 2022 8:29 AMSOFTWARE REVISION LEVEL VERSION 421.00SOFTWARE# 346421-100-A CREATED - 00.11.15.13.40 NO SOFTWARE MODULE >< I11100AUG 22, 2022 8:29 AM 265022 6100 DISTRICT BLVDBAKERSFIELD CA PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 2-24-22 8:08PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 2-23-22 8:11PM L 4 STP SUMP NORTH SUMP SENSOR OUT ALARM CLEAR 6-30-21 12:50PML 3 STP SUMP SOUTH SUMP SENSOR OUT ALARM CLEAR 6-30-21 12:50PM L 1 ANNULAR ANNULAR SENSOR OUT ALARM CLEAR 6-30-21 12:50PML 5 DISP PAN DISPENSER PAN SENSOR OUT ALARM CLEAR 6-30-21 12:50PM L 1 ANNULAR ANNULAR SENSOR OUT ALARM ALARM 6-30-21 12:50PML 4 STP SUMP NORTH SUMP SENSOR OUT ALARM ALARM 6-30-21 12:50PM L 3 STP SUMP SOUTH SUMP SENSOR OUT ALARM ALARM 6-30-21 12:50PML 5 DISP PAN DISPENSER PAN SENSOR OUT ALARM ALARM 6-30-21 12:50PM L 5 DISP PAN DISPENSER PAN FUEL ALARM CLEAR 6-30-21 12:43PM L 5 DISP PAN DISPENSER PAN FUEL ALARM ALARM 6-30-21 12:43PMT 1 TANK DIESEL MAX PRODUCT ALARM CLEAR 6-30-21 12:43PMT 1 TANK DIESEL MAX PRODUCT ALARM ALARM 6-30-21 12:41PML 4 STP SUMP NORTH SUMP FUEL ALARM CLEAR 6-30-21 12:38PML 4 STP SUMP NORTH SUMP FUEL ALARM ALARM 6-30-21 12:38PML 1 ANNULAR ANNULAR FUEL ALARM CLEAR 6-30-21 12:33PML 1 ANNULAR ANNULAR FUEL ALARM ALARM 6-30-21 12:33PML 3 STP SUMP SOUTH SUMP FUEL ALARM CLEAR 6-30-21 12:33PML 3 STP SUMP SOUTH SUMP FUEL ALARM ALARM 6-30-21 12:33PML 5 DISP PAN DISPENSER PAN SENSOR OUT ALARM CLEAR 9-24-20 11:17AML 4 STP SUMP NORTH SUMP SENSOR OUT ALARM CLEAR 9-24-20 11:17AML 1 ANNULAR ANNULAR SENSOR OUT ALARM CLEAR 9-24-20 11:16AML 1 ANNULAR ANNULAR SENSOR OUT ALARM ALARM 9-24-20 11:16AML 5 DISP PAN DISPENSER PAN SENSOR OUT ALARM ALARM 9-24-20 11:16AML 4 STP SUMP NORTH SUMP SENSOR OUT ALARM ALARM 9-24-20 11:16AMT 1 TANK DIESEL PROBE OUT CLEAR 9-24-20 11:16AMT 1 TANK DIESEL OVERFILL ALARM CLEAR 9-24-20 11:15AMT 1 TANK DIESEL PROBE OUT ALARM 9-24-20 11:15AMT 1 TANK DIESEL OVERFILL ALARM ALARM 9-24-20 11:14AMT 1 TANK DIESEL PROBE OUT CLEAR 9-24-20 11:12AMT 1 TANK DIESEL PROBE OUT ALARM 9-24-20 11:11AML 5 DISP PAN DISPENSER PAN FUEL ALARM CLEAR 9-24-20 11:10AML 5 DISP PAN DISPENSER PAN FUEL ALARM ALARM 9-24-20 11:09AML 1 ANNULAR ANNULAR FUEL ALARM CLEAR 9-24-20 11:08AML 1 ANNULAR ANNULAR FUEL ALARM ALARM 9-24-20 11:08AML 3 STP SUMP SOUTH SUMP FUEL ALARM CLEAR 9-24-20 11:07AML 3 STP SUMP SOUTH SUMP FUEL ALARM ALARM 9-24-20 11:07AML 4 STP SUMP NORTH SUMP FUEL ALARM CLEAR 9-24-20 11:06AML 4 STP SUMP NORTH SUMP FUEL ALARM ALARM 9-24-20 11:06AMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 11-04-19 7:36PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 11-03-19 6:23PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 11-03-19 6:23PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 11-02-19 7:00PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 9-26-19 8:23AMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 9-22-19 5:53AMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 9-22-19 5:53AMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 9-21-19 1:00PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 9-21-19 1:00PMD 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 9-19-19 6:40PM ><I11200AUG 22, 2022 8:30 AM 265022 6100 DISTRICT BLVDBAKERSFIELD CA NON-PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 5-24-22 7:01PM SYSTEM PAPER OUT CLEAR 5-24-22 7:01PM SYSTEM PAPER OUT ALARM 5-24-22 7:01PM SYSTEM PRINTER ERROR ALARM 5-24-22 7:01PM SYSTEM PRINTER ERROR CLEAR 5-24-22 7:01PM SYSTEM PAPER OUT CLEAR 5-24-22 7:01PM SYSTEM PRINTER ERROR ALARM 5-24-22 7:01PM SYSTEM PAPER OUT ALARM 5-24-22 7:01PM SYSTEM PRINTER ERROR CLEAR 5-24-22 7:01PM SYSTEM PAPER OUT CLEAR 5-24-22 7:01PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:55PM SYSTEM PAPER OUT ALARM 5-24-22 2:55PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:53PM SYSTEM PAPER OUT CLEAR 5-24-22 2:53PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:52PM SYSTEM PAPER OUT ALARM 5-24-22 2:52PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:52PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:52PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:52PM SYSTEM PAPER OUT CLEAR 5-24-22 2:52PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:52PM SYSTEM PAPER OUT ALARM 5-24-22 2:52PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:51PM SYSTEM PAPER OUT CLEAR 5-24-22 2:51PM SYSTEM PAPER OUT ALARM 5-24-22 2:51PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:51PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:50PM SYSTEM PAPER OUT CLEAR 5-24-22 2:50PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:42PM SYSTEM PAPER OUT ALARM 5-24-22 2:42PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:41PM SYSTEM PAPER OUT CLEAR 5-24-22 2:41PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:41PM SYSTEM PAPER OUT ALARM 5-24-22 2:41PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:41PM SYSTEM PAPER OUT CLEAR 5-24-22 2:41PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:41PM SYSTEM PAPER OUT ALARM 5-24-22 2:41PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:41PM SYSTEM PAPER OUT CLEAR 5-24-22 2:41PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:41PM SYSTEM PAPER OUT ALARM 5-24-22 2:41PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:40PM SYSTEM PAPER OUT CLEAR 5-24-22 2:40PM SYSTEM PRINTER ERROR ALARM 5-24-22 2:40PM SYSTEM PAPER OUT ALARM 5-24-22 2:40PM SYSTEM PRINTER ERROR CLEAR 5-24-22 2:40PM SYSTEM PAPER OUT CLEAR 5-24-22 2:40PM SYSTEM PRINTER ERROR ALARM 4-27-22 2:38PM SYSTEM PAPER OUT ALARM 4-27-22 2:38PM >< I20600AUG 22, 2022 8:31 AM 265022 6100 DISTRICT BLVDBAKERSFIELD CA TANK ALARM HISTORY TANK 1 DIESEL OVERFILL ALARM SEP 24, 2020 11:14 AM SEP 3, 2019 3:23 PM JUL 18, 2019 11:05 AM LOW PRODUCT ALARM JUL 18, 2019 10:50 AM MAR 6, 2008 12:25 AM HIGH PRODUCT ALARM JUN 30, 2021 12:41 PM JUN 17, 2014 9:38 AM JUN 12, 2012 8:51 AM INVALID FUEL LEVEL JUL 18, 2019 10:50 AM JUN 12, 2012 8:14 AM APR 8, 2011 4:03 PM PROBE OUT SEP 24, 2020 11:15 AM SEP 24, 2020 11:11 AM JUL 18, 2019 11:37 AM DELIVERY NEEDED JUL 18, 2019 10:50 AM MAR 6, 2008 12:15 AM MAX PRODUCT ALARM JUN 30, 2021 12:41 PM JUN 17, 2014 9:38 AM JUN 12, 2012 8:51 AM LOW TEMP WARNING MAR 13, 2019 8:25 PM JUN 17, 2014 10:44 AM JUN 12, 2012 9:18 AM ><9999FF1B><9999FF1B><I30200AUG 22, 2022 8:31 AM 265022 6100 DISTRICT BLVDBAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR JUN 30, 2021 12:50 PM SENSOR OUT ALARM JUN 30, 2021 12:33 PM FUEL ALARM SEP 24, 2020 11:16 AM SENSOR OUT ALARM 3 SOUTH SUMP JUN 30, 2021 12:50 PM SENSOR OUT ALARM JUN 30, 2021 12:33 PM FUEL ALARM SEP 24, 2020 11:07 AM FUEL ALARM 4 NORTH SUMP JUN 30, 2021 12:50 PM SENSOR OUT ALARM JUN 30, 2021 12:38 PM FUEL ALARM SEP 24, 2020 11:16 AM SENSOR OUT ALARM 5 DISPENSER PAN JUN 30, 2021 12:50 PM SENSOR OUT ALARM JUN 30, 2021 12:43 PM FUEL ALARM SEP 24, 2020 11:16 AM SENSOR OUT ALARM ><9999FF1B> <I10200 AUG 22, 2022 8:32 AM 265022 6100 DISTRICT BLVD BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 FOUR PROBE BD. 2003 2000 2 INTERSTITIAL BD 201230 201314 3 UNUSED 9851524 9520139 4 UNUSED 9849790 9521085 5 UNUSED 9849459 9522738 6 UNUSED 9849615 9520929 7 UNUSED 9849778 9522520 8 UNUSED 9848289 9520618 9 UNUSED 9851854 9523795 10 UNUSED 9850097 9522581 11 UNUSED 9850979 9522881 12 UNUSED 9851667 9523122 13 UNUSED 9851714 9521154 14 UNUSED 9851807 9524055 15 UNUSED 9850221 9522406 16 COMBO I/O BOARD 10028 10029 COMM 1 SERIAL SAT BD 40490 477645 COMM 2 RS232 SERIAL BD 15036 15040 COMM 3 PRINTER BOARD 10032 10029 > <I90200AUG 22, 2022 8:32 AMSOFTWARE REVISION LEVELVERSION 421.00SOFTWARE# 346421-100-A CREATED - 00.11.15.13.40 NO SOFTWARE MODULE > SHEAR VALVE OPERATION INSPECTION Facility Name: Owner Address: Address City, State, Zip Code: City, State, Zip Code: CERS I.D. #:Owner Phone #: Testing Company: Phone #: This data sheet is for inspecting shear valves located inside dispensers. See PEI/RP1200 Section 10 for the inspection procedure. Product Grade Dispenser ID# Shear ValveType (Product/Vapor) 1. Is the shear valve rigidly anchored to the dispenser box frame or dispenser island? Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No 2. Is the shear section posi- tioned between ½ inch above or below the top surface of the dispenser island? Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No 3. Is the lever arm free to move? Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA 4.Does the lever arm snap the the poppet valve shut? Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA 5. Can any product be dispensed when the product shear valve is closed? Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA A “No” to Lines 1-4 or a “Yes” for Line 5 indicates a test failure. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name (print) Tester’s Signature Reference PEI/RP1200-19 Appendix C-10 Date: Latest Version 3/14/2022