HomeMy WebLinkAboutCold Start Results 6/22Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10134223 06-02-2022 Jaco#2233D&G 2732 Brundage Lane Bakersfield 93301 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Frank Amestoy 1073967 8374998 10-22-2023 Veeder root 07-31-2022 06-02-2022 5 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder root TLS-350 327.04 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1: 794380-208 UDC 1/2 Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. NOPARKING N EXISTING BUILDING H W W G R 1 2 L1 S T P F 1 2 , 0 0 0 G A L L O N D I E S E L 1 2 , 0 0 0 G A L L O N 8 7 U N L E A D E D 1 2 , 0 0 0 G A L L O N P R E M I U M V F V F S T P S T P A N O D E DUMPSTER PRICE SIGN MYRTLE ST. BR U N D A G E L N . PROPERTY LINE PR O P E R T Y L I N E 141' 73 . 5 ' LEGEND L1 UDC 1 - 2 87 GAS 2 INCH SINGLE WALLED PIPE 91 GAS 2 INCH SINGLE WALLED PIPE DIESEL 2 INCH SINGLE WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER SHUTOFF EVACUATION MEETING POINT RECTIFIER AUTOMATIC TANK GAUGE CIRCUIT BREAKER AIR AND WATER DISPENSER G P V W R SITE MAP C1 VICINITY MAP PROJECT DATA 1/8"=1'-0" INCHES012 SHEET SIZE 22 X 34 SCALE: 2732 BRUNDAGE LN. BAKERSFIELD, CA 93304 O A K S T . E BRUNDAGE LN. PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-002916 CERS ID 10134223 FASTRIP #2233 2732 BRUNDAGE LN. BAKERSFIELD, CA 93304 12/21/16 REV. D&G liquor after cold start setup Responses Received: 200 D AND G 233 2732 BRUNDAGE LN BAKERSFFILD CA 9330 661-326-1083 JUN 2, 2022 11:29 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 8336 62.92 0.0 84.3 3664 2 PREMIUM 1350 16.30 0.8 89.8 10650 3 DIESEL 1402 16.73 0.0 84.7 10598 I90500 JUN 2, 2022 11:29 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-062-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I50500 JUN 2, 2022 11:29 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUN 2, 2022 11:29 AM SHIFT TIME 1 : DISABLED I50202 JUN 2, 2022 11:29 AM SHIFT TIME 2 : DISABLED I50203 JUN 2, 2022 11:29 AM SHIFT TIME 3 : DISABLED I50204 JUN 2, 2022 11:29 AM SHIFT TIME 4 : DISABLED I54600 JUN 2, 2022 11:29 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUN 2, 2022 11:29 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUN 2, 2022 11:29 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUN 2, 2022 11:29 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUN 2, 2022 11:29 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUN 2, 2022 11:29 AM PRINT TC VOLUMES ENABLED I50E00 JUN 2, 2022 11:29 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUN 2, 2022 11:29 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUN 2, 2022 11:29 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUN 2, 2022 11:29 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUN 2, 2022 11:29 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUN 2, 2022 11:29 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUN 2, 2022 11:29 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUN 2, 2022 11:29 AM TANK CHART SECURITY DISABLED I5BD00 JUN 2, 2022 11:29 AM CUSTOM ALARM LABELS DISABLED I56000 JUN 2, 2022 11:29 AM MASS/DENSITY DISABLED I88101 JUN 2, 2022 11:29 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 JUN 2, 2022 11:29 AM I88103 JUN 2, 2022 11:29 AM I88104 JUN 2, 2022 11:29 AM I88105 JUN 2, 2022 11:29 AM I88106 JUN 2, 2022 11:29 AM I52000 JUN 2, 2022 11:29 AM I60100 JUN 2, 2022 11:29 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 JUN 2, 2022 11:29 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 JUN 2, 2022 11:29 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 JUN 2, 2022 11:29 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 JUN 2, 2022 11:29 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 96.00 2 PREMIUM 96.00 3 DIESEL 96.00 4 0.00 I60A00 JUN 2, 2022 11:29 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12000 2 PREMIUM 1 PT 12000 3 DIESEL 1 PT 12000 4 1 PT 0 I60400 JUN 2, 2022 11:29 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 PREMIUM 12000 3 DIESEL 12000 4 0 I60500 JUN 2, 2022 11:29 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 2 PREMIUM 12000 0 0 0 3 DIESEL 12000 0 0 0 4 0 0 0 0 I60600 JUN 2, 2022 11:29 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 PREMIUM 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUN 2, 2022 11:29 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 JUN 2, 2022 11:29 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 INCHES 2 PREMIUM 4.0 INCHES 3 DIESEL 4.0 INCHES I62700 JUN 2, 2022 11:29 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 9999FF1B I62400 JUN 2, 2022 11:29 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 JUN 2, 2022 11:29 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 PREMIUM 12000 3 DIESEL 12000 4 0 I62300 JUN 2, 2022 11:29 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10800 2 PREMIUM 10800 3 DIESEL 10800 4 0 I62200 JUN 2, 2022 11:29 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11400 2 PREMIUM 11400 3 DIESEL 11400 4 0 I62900 JUN 2, 2022 11:29 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1800 2 PREMIUM 1800 3 DIESEL 1800 4 0 I62100 JUN 2, 2022 11:29 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 600 2 PREMIUM 600 3 DIESEL 600 4 0 I62600 JUN 2, 2022 11:29 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 JUN 2, 2022 11:29 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I60800 JUN 2, 2022 11:30 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I60B00 JUN 2, 2022 11:30 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUN 2, 2022 11:30 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 JUN 2, 2022 11:30 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 JUN 2, 2022 11:30 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62A00 JUN 2, 2022 11:30 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62C00 JUN 2, 2022 11:30 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 JUN 2, 2022 11:30 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUN 2, 2022 11:30 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 JUN 2, 2022 11:30 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 JUN 2, 2022 11:30 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 JUN 2, 2022 11:30 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63A00 JUN 2, 2022 11:30 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 JUN 2, 2022 11:30 AM LEAK TEST METHOD - - - - - - - - - - - - TEST CSLD : ALL TANK Pd = 95% CLIMATE FACTOR:MODERATE GROSS TEST AUTO-CONFIRM: DISABLED REPORT ONLY: DISABLED TST EARLY STOP:DISABLED I61300 JUN 2, 2022 11:30 AM CSLD PROBABLITY OF DETECTION T 1:UNLEADED : Pd = 95% T 2:PREMIUM : Pd = 95% T 3:DIESEL : Pd = 95% I61400 JUN 2, 2022 11:30 AM CSLD CLIMATE FACTOR T 1:UNLEADED : MODERATE T 2:PREMIUM : MODERATE T 3:DIESEL : MODERATE I61600 JUN 2, 2022 11:30 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 JUN 2, 2022 11:30 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 JUN 2, 2022 11:30 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM TANK PRODUCT LABEL AUTO-CONFIRM 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED I61C00 JUN 2, 2022 11:30 AM CSLD REPORT ONLY TANK PRODUCT LABEL CSLD REPORT ONLY 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED I62B00 JUN 2, 2022 11:30 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 PREMIUM ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 JUN 2, 2022 11:30 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUN 2, 2022 11:30 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 JUN 2, 2022 11:30 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 JUN 2, 2022 11:30 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 JUN 2, 2022 11:30 AM I77700 JUN 2, 2022 11:30 AM I77800 JUN 2, 2022 11:30 AM I78C00 JUN 2, 2022 11:30 AM I78300 JUN 2, 2022 11:30 AM I78F00 JUN 2, 2022 11:30 AM I78700 JUN 2, 2022 11:30 AM I70200 JUN 2, 2022 11:30 AM LIQUID LABEL DEVICE LABEL 1 DISP 1 2 3 4 5 6 7 8 I70300 JUN 2, 2022 11:30 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1 TRI-STATE (SINGLE FLOAT) 2 TRI-STATE (SINGLE FLOAT) 3 TRI-STATE (SINGLE FLOAT) 4 TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I70400 JUN 2, 2022 11:30 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1 DISPENSER PAN 2 OTHER SENSORS 3 OTHER SENSORS 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS I74200 JUN 2, 2022 11:30 AM I74300 JUN 2, 2022 11:30 AM I74400 JUN 2, 2022 11:30 AM I74700 JUN 2, 2022 11:30 AM I74800 JUN 2, 2022 11:30 AM I74900 JUN 2, 2022 11:30 AM I7BC00 JUN 2, 2022 11:30 AM I80200 JUN 2, 2022 11:30 AM I80300 JUN 2, 2022 11:30 AM I80400 JUN 2, 2022 11:30 AM I80700 JUN 2, 2022 11:30 AM RELAY LABEL DEVICE LABEL 1 OVERFILL ALARM 2 3 4 I80900 JUN 2, 2022 11:30 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 OVERFILL ALARM NORMALLY OPEN 2 NORMALLY OPEN 3 NORMALLY OPEN 4 NORMALLY OPEN I80B00 JUN 2, 2022 11:30 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 OVERFILL ALARM NONE 2 NONE 3 NONE 4 NONE I80A00 JUN 2, 2022 11:30 AM RELAY TYPE RELAY DESIGNATION TYPE 1 OVERFILL ALARM STANDARD 2 STANDARD 3 STANDARD 4 STANDARD I80C00 JUN 2, 2022 11:30 AM I80800 JUN 2, 2022 11:30 AM RELAY SETUP REPORT R 1:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 2: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - I79000 JUN 2, 2022 11:30 AM I79100 JUN 2, 2022 11:30 AM I72300 JUN 2, 2022 11:30 AM IV4E00 JUN 2, 2022 11:30 AM IV4F00 JUN 2, 2022 11:30 AM IV4000 JUN 2, 2022 11:30 AM IV4700 JUN 2, 2022 11:30 AM IV5200 JUN 2, 2022 11:30 AM IV4A00 JUN 2, 2022 11:30 AM IV4B00 JUN 2, 2022 11:30 AM IV4900 JUN 2, 2022 11:30 AM IV1000 JUN 2, 2022 11:30 AM ISD VERSION: 01.01 D&G liquor after cold start alarm history Responses Received: I10200 JUN 2, 2022 11:33 AM D AND G 233 2732 BRUNDAGE LN BAKERSFFILD CA 9330 661-326-1083 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 INTERSTITIAL BD 201162 201162 2 4 PROBE / G.T. 164019 164019 3 UNUSED 9810446 9810446 4 UNUSED 9790645 9790645 5 UNUSED 9792695 9792695 6 UNUSED 9786833 9786833 7 UNUSED 9785603 9785603 8 UNUSED 9783307 9783307 9 WPLLD POWER BD 202397 202397 10 AC INTERFACE BD 164236 164236 11 RELAY BOARD 15076 15076 12 UNUSED 9799395 9799395 13 UNUSED 9790089 9790089 14 UNUSED 9801301 9801301 15 UNUSED 9786707 9786707 16 UNUSED 9789372 9789372 COMM 1 RS232 SERIAL BD 14952 14952 COMM 2 WPLLD COMM BD 202440 202440 COMM 3 UNUSED 9797448 9797448 COMM 4 UNUSED 9779840 9779840 COMM 5 UNUSED 9792282 9792282 COMM 6 UNUSED 9788613 9788613 I90200 JUN 2, 2022 11:33 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-062-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 JUN 2, 2022 11:33 AM D AND G 233 2732 BRUNDAGE LN BAKERSFFILD CA 9330 661-326-1083 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED SUDDEN LOSS ALARM ALARM 6-02-22 11:22AM W 3 OTHER PREMIUM WPLLD SHUTDOWN ALM CLEAR 6-02-22 11:19AM W 2 OTHER UNLEADED WPLLD SHUTDOWN ALM CLEAR 6-02-22 11:19AM W 1 OTHER DIESEL WPLLD SHUTDOWN ALM CLEAR 6-02-22 11:19AM L 1 DISP PAN DISP 1 FUEL ALARM CLEAR 6-02-22 11:19AM T 2 TANK PREMIUM PROBE OUT CLEAR 6-02-22 11:18AM T 1 TANK UNLEADED PROBE OUT CLEAR 6-02-22 11:18AM T 3 TANK DIESEL PROBE OUT CLEAR 6-02-22 11:18AM L 1 DISP PAN DISP 1 FUEL ALARM ALARM 6-02-22 11:18AM W 3 OTHER PREMIUM WPLLD SHUTDOWN ALM ALARM 6-02-22 11:18AM W 2 OTHER UNLEADED WPLLD SHUTDOWN ALM ALARM 6-02-22 11:18AM W 1 OTHER DIESEL WPLLD SHUTDOWN ALM ALARM 6-02-22 11:18AM T 3 TANK DIESEL PROBE OUT ALARM 6-02-22 11:18AM T 2 TANK PREMIUM PROBE OUT ALARM 6-02-22 11:18AM T 1 TANK UNLEADED PROBE OUT ALARM 6-02-22 11:18AM W 3 OTHER PREMIUM WPLLD SHUTDOWN ALM CLEAR 2-06-07 8:25AM W 2 OTHER UNLEADED WPLLD SHUTDOWN ALM CLEAR 2-06-07 8:25AM W 1 OTHER DIESEL WPLLD SHUTDOWN ALM CLEAR 2-06-07 8:25AM L 1 DISP PAN DISP 1 FUEL ALARM CLEAR 2-06-07 8:25AM L 1 DISP PAN DISP 1 FUEL ALARM ALARM 2-06-07 8:25AM W 3 OTHER PREMIUM WPLLD SHUTDOWN ALM ALARM 2-06-07 8:25AM W 2 OTHER UNLEADED WPLLD SHUTDOWN ALM ALARM 2-06-07 8:25AM W 1 OTHER DIESEL WPLLD SHUTDOWN ALM ALARM 2-06-07 8:25AM SYSTEM BATTERY IS OFF CLEAR 2-06-07 8:00AM SYSTEM BATTERY IS OFF ALARM 2-06-07 8:00AM I11200 JUN 2, 2022 11:33 AM D AND G 233 2732 BRUNDAGE LN BAKERSFFILD CA 9330 661-326-1083 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 6-02-22 11:22AM T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 6-02-22 11:22AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 6-02-22 11:22AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 6-02-22 11:22AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 6-02-22 11:22AM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 6-02-22 11:21AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 6-02-22 11:21AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 6-02-22 11:21AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 6-02-22 11:21AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 6-02-22 11:21AM W 3 OTHER PREMIUM SETUP DATA WARNING CLEAR 2-06-07 8:05AM W 2 OTHER UNLEADED SETUP DATA WARNING CLEAR 2-06-07 8:05AM W 1 OTHER DIESEL SETUP DATA WARNING CLEAR 2-06-07 8:05AM W 3 OTHER PREMIUM SETUP DATA WARNING ALARM 2-06-07 8:05AM W 2 OTHER UNLEADED SETUP DATA WARNING ALARM 2-06-07 8:05AM W 1 OTHER DIESEL SETUP DATA WARNING ALARM 2-06-07 8:05AM L 1 DISP PAN DISP 1 SETUP DATA WARNING CLEAR 2-06-07 8:05AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 2-06-07 8:05AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 2-06-07 8:05AM L 1 DISP PAN DISP 1 SETUP DATA WARNING ALARM 2-06-07 8:02AM I20600 JUN 2, 2022 11:33 AM D AND G 233 2732 BRUNDAGE LN BAKERSFFILD CA 9330 661-326-1083 TANK ALARM HISTORY TANK 1 UNLEADED SUDDEN LOSS ALARM JUN 2, 2022 11:22 AM HIGH PRODUCT ALARM JUN 2, 2022 11:21 AM PROBE OUT JUN 2, 2022 11:18 AM TANK 2 PREMIUM HIGH PRODUCT ALARM JUN 2, 2022 11:21 AM PROBE OUT JUN 2, 2022 11:18 AM DELIVERY NEEDED JUN 2, 2022 11:22 AM FEB 6, 2007 8:05 AM TANK 3 DIESEL HIGH PRODUCT ALARM JUN 2, 2022 11:21 AM PROBE OUT JUN 2, 2022 11:18 AM DELIVERY NEEDED JUN 2, 2022 11:22 AM FEB 6, 2007 8:05 AM I38200 JUN 2, 2022 11:33 AM I30200 JUN 2, 2022 11:33 AM D AND G 233 2732 BRUNDAGE LN BAKERSFFILD CA 9330 661-326-1083 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1 JUN 2, 2022 11:18 AM FUEL ALARM FEB 6, 2007 8:25 AM FUEL ALARM FEB 6, 2007 8:02 AM SETUP DATA WARNING I31600 JUN 2, 2022 11:33 AM I40200 JUN 2, 2022 11:33 AM I40300 JUN 2, 2022 11:33 AM I34200 JUN 2, 2022 11:33 AM I34700 JUN 2, 2022 11:33 AM IV0100 JUN 2, 2022 11:33 AM