Loading...
HomeMy WebLinkAboutFMC 2022Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10022950 8/19/2022 Grand Avenue Coast, Inc. (ARCO) 4203 Ming Avenue Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 Veeder Root B47853 7/31/2024 OPW 0148613 8/19/2022 8/19/2022 5 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.01 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 409 Unl Ann L2 208 Unl STP L3 208 Unl Fill S L4 409 Unl 2 Ann L5 208 Unl 2 Sy L6 208 Unl M Fill L7 409 Unl 3 Ann L8 208 Unl 3 Sy L9 208 Unl N Fill L10 409 Prem Ann L11 208 Prem Fill L12 208 Prem STP L13 208 Disp-2 L14 208 Disp 3-4 L15 208 Disp 5-6 L16 208 Disp 7-8 L17 208 Disp 9-10 L18 208 Disp 11-12 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Q1 848480-001 Unl Q2 848480-001 Prem Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ APPENDIX C-10 SH E A R V A L V E O P E R A T I O N I N S P E C T I O N )D F L O L W \  1 D P H  2Z Q H U $G G U H V V  $G G U H V V &L W \   6 W D W H   = L S  & R G H  &L W \   6 W D W H   = L S  & R G H  )D F L O L W \  ,  '     3K R Q H    7H V W L Q J  & R P S D Q \  3K R Q H    7K L V  G D W D  V K H H W  L V  I R U  L Q V S H F W L Q J  V K H D U  Y D O Y H V  O R F D W H G  L Q V L G H  G LV S H Q V H U V   6 H H  3 ( ,  5 3       6 H F W L R Q     I R U  W K H  L Q V S H F W L R Q  S U R F H G XU H  3U R G X F W  * U D G H 'L V S H Q V H U  , '      6K H D U  9 D O Y H 7 \ S H  3 U R G X F W  9 D S R U   , V  W K H  V K H D U  Y D O Y H  U L J L G O \  DQ F K R U H G  W R  W K H  G L V S H Q V H U  E R [  IU D P H  R U  G L V S H Q V H U  L V O D Q G " < H V    1 R < H V    1 R < H V    1 R < H V    1 R < H V    1 R < H V    1 R < H V    1 R <HV1R <HV1R   , V  W K H  V K H D U  V H F W L R Q  S R V L  WL R Q H G  E H W Z H H Q  ó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´ 1 R µ  W R  / L Q H V      R U  D  ´ < H V µ  I R U  / L Q H    L Q G L F D W H V  D  W H V W  I D L O XU H  Te s t R e s u l t s 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3DVV)DLO3DVV)DLO Co m m e n t s : 7H V W H U · V  1 D PH  BB B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B  7H V W H U · V  6 L J Q D W X U H  BB B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B 1Z H V W F R  / / &            Gr a n d A v e n u e C o a s t , I n c . ( A R C O ) 42 0 3 M i n g A v e n u e Ba k e r s f i e l d 10 0 2 2 9 5 0 3- 4 7- 8 1 1 - 1 2 MP D MP D MP D MP D MP D MP D 1- 2 5- 6 9- 1 0 Pr o d u c t Pr o d u c t Pr o d u c t Pr o d u c t Pr o d u c t Pr o d u c t Aa r o n P e r r i g o Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10022950 8/19/2022 Grand Avenue Coast, Inc. (ARCO) 4203 Ming Avenue Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 OPW 0148613 7/10/2024 Lake Test Al 4 fill spill buckets 8/19/2022 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. Unl 1 OPW Unl 2 OPW Unl 3 OPW Prem OPW Grand Ave Setup Responses Received: 200 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 AUG 19, 2022 8:53 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 1 1668 21.29 0.1 89.9 8332 2 UNLEADED 2 TURBN 1976 24.02 0.8 91.0 8024 3 UNLEADED 3 2289 26.70 0.0 88.5 7711 4 PREMIUM 1714 21.71 0.0 88.8 8286 I90500 AUG 19, 2022 8:53 AM SOFTWARE REVISION LEVEL VERSION 336.01 SOFTWARE# 346336-100-B CREATED - 20.04.26.20.30 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 AUG 19, 2022 8:53 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 19, 2022 8:53 AM SHIFT TIME 1 : DISABLED I50202 AUG 19, 2022 8:53 AM SHIFT TIME 2 : DISABLED I50203 AUG 19, 2022 8:53 AM SHIFT TIME 3 : DISABLED I50204 AUG 19, 2022 8:53 AM SHIFT TIME 4 : DISABLED I54600 AUG 19, 2022 8:53 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 19, 2022 8:53 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 19, 2022 8:53 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 19, 2022 8:53 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 19, 2022 8:53 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 19, 2022 8:53 AM PRINT TC VOLUMES ENABLED I50E00 AUG 19, 2022 8:53 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 19, 2022 8:53 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 19, 2022 8:53 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 19, 2022 8:53 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 19, 2022 8:53 AM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 AUG 19, 2022 8:53 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 19, 2022 8:53 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 19, 2022 8:53 AM TANK CHART SECURITY DISABLED I5BD00 AUG 19, 2022 8:53 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 19, 2022 8:53 AM MASS/DENSITY DISABLED I88101 AUG 19, 2022 8:53 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 AUG 19, 2022 8:53 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 19, 2022 8:53 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 AUG 19, 2022 8:53 AM I88105 AUG 19, 2022 8:53 AM PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88106 AUG 19, 2022 8:53 AM PORT SETTINGS: COMM BOARD : 6 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I52000 AUG 19, 2022 8:53 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUL 17, 2006 DISABLED 2 ON DATE JUL 17, 2006 DISABLED 3 ON DATE JUL 17, 2006 DISABLED 4 ON DATE JUL 17, 2006 DISABLED 5 ON DATE JUL 17, 2006 DISABLED 6 ON DATE JUL 17, 2006 DISABLED 7 ON DATE JUL 17, 2006 DISABLED 8 VEEDER ROOT (FMS) ON DATE JUN 13, 2006 11:46 AM I60100 AUG 19, 2022 8:53 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED 1 ON 2 UNLEADED 2 TURBN ON 3 UNLEADED 3 ON 4 PREMIUM ON I60200 AUG 19, 2022 8:53 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 TURBN 3 UNLEADED 3 4 PREMIUM I60300 AUG 19, 2022 8:54 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 1 2 UNLEADED 2 TURBN 1 3 UNLEADED 3 1 4 PREMIUM 2 I60900 AUG 19, 2022 8:54 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 1 0.000700 2 UNLEADED 2 TURBN 0.000700 3 UNLEADED 3 0.000700 4 PREMIUM 0.000700 I60700 AUG 19, 2022 8:54 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 1 96.00 2 UNLEADED 2 TURBN 96.00 3 UNLEADED 3 96.00 4 PREMIUM 96.00 I60A00 AUG 19, 2022 8:54 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 4 PTS 10000 2 UNLEADED 2 TURBN 4 PTS 10000 3 UNLEADED 3 4 PTS 10000 4 PREMIUM 4 PTS 10000 I60400 AUG 19, 2022 8:54 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 10000 2 UNLEADED 2 TURBN 10000 3 UNLEADED 3 10000 4 PREMIUM 10000 I60500 AUG 19, 2022 8:54 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 10000 8079 5061 1973 2 UNLEADED 2 TURBN 10000 8079 5061 1973 3 UNLEADED 3 10000 8079 5061 1973 4 PREMIUM 10000 8079 5061 1973 I60600 AUG 19, 2022 8:54 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 10000 0 0 0 0 8079 0 0 0 0 5061 0 0 0 0 1973 0 0 0 0 2 UNLEADED 2 TURBN 10000 0 0 0 0 8079 0 0 0 0 5061 0 0 0 0 1973 0 0 0 0 3 UNLEADED 3 10000 0 0 0 0 8079 0 0 0 0 5061 0 0 0 0 1973 0 0 0 0 4 PREMIUM 10000 0 0 0 0 8079 0 0 0 0 5061 0 0 0 0 1973 0 0 0 0 I61500 AUG 19, 2022 8:54 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED 1 NO 2 UNLEADED 2 TURBN NO 3 UNLEADED 3 NO 4 PREMIUM NO I62F00 AUG 19, 2022 8:54 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 1 4.0 IN. 2 UNLEADED 2 TURBN 4.0 IN. 3 UNLEADED 3 4.0 IN. 4 PREMIUM 4.0 IN. I62700 AUG 19, 2022 8:54 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 1 2.5 2 UNLEADED 2 TURBN 2.5 3 UNLEADED 3 2.5 4 PREMIUM 2.5 I64200 AUG 19, 2022 8:54 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED 1 LOW 2 UNLEADED 2 TURBN LOW 3 UNLEADED 3 LOW 4 PREMIUM LOW I62400 AUG 19, 2022 8:54 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 1 3.0 2 UNLEADED 2 TURBN 3.0 3 UNLEADED 3 3.0 4 PREMIUM 3.0 I62800 AUG 19, 2022 8:54 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 10000 2 UNLEADED 2 TURBN 10000 3 UNLEADED 3 10000 4 PREMIUM 10000 I62300 AUG 19, 2022 8:54 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 9000 2 UNLEADED 2 TURBN 9000 3 UNLEADED 3 9000 4 PREMIUM 9000 I62200 AUG 19, 2022 8:54 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 9500 2 UNLEADED 2 TURBN 9500 3 UNLEADED 3 9500 4 PREMIUM 9500 I62900 AUG 19, 2022 8:54 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2000 2 UNLEADED 2 TURBN 2000 3 UNLEADED 3 2000 4 PREMIUM 2000 I62100 AUG 19, 2022 8:54 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 1000 2 UNLEADED 2 TURBN 1000 3 UNLEADED 3 1000 4 PREMIUM 1000 I62600 AUG 19, 2022 8:54 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 99 2 UNLEADED 2 TURBN 99 3 UNLEADED 3 99 4 PREMIUM 99 I62500 AUG 19, 2022 8:54 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 99 2 UNLEADED 2 TURBN 99 3 UNLEADED 3 99 4 PREMIUM 99 I60800 AUG 19, 2022 8:54 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 1 0.00 2 UNLEADED 2 TURBN 0.00 3 UNLEADED 3 0.00 4 PREMIUM 0.00 I60B00 AUG 19, 2022 8:54 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 19, 2022 8:54 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 1 0.00 2 UNLEADED 2 TURBN 0.00 3 UNLEADED 3 0.00 4 PREMIUM 0.00 I61200 AUG 19, 2022 8:54 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED 1 NONE NONE 2 UNLEADED 2 TURBN NONE NONE 3 UNLEADED 3 NONE NONE 4 PREMIUM NONE NONE I63600 AUG 19, 2022 8:54 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 0 2 UNLEADED 2 TURBN 0 3 UNLEADED 3 0 4 PREMIUM 0 I62A00 AUG 19, 2022 8:54 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 0 2 UNLEADED 2 TURBN 0 3 UNLEADED 3 0 4 PREMIUM 0 I62C00 AUG 19, 2022 8:54 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED 1 STANDARD 2 UNLEADED 2 TURBN STANDARD 3 UNLEADED 3 STANDARD 4 PREMIUM STANDARD I62D00 AUG 19, 2022 8:54 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED 2 TURBN GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 UNLEADED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 19, 2022 8:54 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED 1 OFF OFF 2 UNLEADED 2 TURBN OFF OFF 3 UNLEADED 3 OFF OFF 4 PREMIUM OFF OFF I63000 AUG 19, 2022 8:54 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED 1 OFF 2 UNLEADED 2 TURBN OFF 3 UNLEADED 3 OFF 4 PREMIUM OFF I63200 AUG 19, 2022 8:54 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED 1 OFF 2 UNLEADED 2 TURBN OFF 3 UNLEADED 3 OFF 4 PREMIUM OFF I61000 AUG 19, 2022 8:54 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 2 UNLEADED 2 TURBN 2 3 UNLEADED 3 2 4 PREMIUM 2 I63A00 AUG 19, 2022 8:54 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 1 10.00% 2 UNLEADED 2 TURBN 10.00% 3 UNLEADED 3 10.00% 4 PREMIUM 3.00% I61100 AUG 19, 2022 8:54 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK NOV 10, 2003 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 19, 2022 8:54 AM CSLD PROBABLITY OF DETECTION I61400 AUG 19, 2022 8:54 AM CSLD CLIMATE FACTOR I61600 AUG 19, 2022 8:54 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED 1 IMMEDIATE 2 UNLEADED 2 TURBN IMMEDIATE 3 UNLEADED 3 IMMEDIATE 4 PREMIUM IMMEDIATE I61A00 AUG 19, 2022 8:54 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED 1 DISABLED 2 UNLEADED 2 TURBN DISABLED 3 UNLEADED 3 DISABLED 4 PREMIUM DISABLED I61B00 AUG 19, 2022 8:54 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 19, 2022 8:54 AM CSLD REPORT ONLY I62B00 AUG 19, 2022 8:54 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 1 ??? 0, 0 2 UNLEADED 2 TURBN ??? 0, 0 3 UNLEADED 3 ??? 0, 0 4 PREMIUM ??? 0, 0 I63300 AUG 19, 2022 8:54 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 19, 2022 8:54 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 0 2 UNLEADED 2 TURBN 0 3 UNLEADED 3 0 4 PREMIUM 0 I63500 AUG 19, 2022 8:54 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 1 2 UNLEADED 2 TURBN 1 3 UNLEADED 3 1 4 PREMIUM 1 I63900 AUG 19, 2022 8:54 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED 1 END FACTOR: NONE 2 UNLEADED 2 TURBN END FACTOR: NONE 3 UNLEADED 3 END FACTOR: NONE 4 PREMIUM END FACTOR: NONE I78000 AUG 19, 2022 8:54 AM PRESSURE LINE LEAK SETUP Q 1:87 REG UNL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 320 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 1:UNLEADED 1 DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:92 PREM UNL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 300 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 4:PREMIUM DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO I77700 AUG 19, 2022 8:54 AM I77800 AUG 19, 2022 8:54 AM I78C00 AUG 19, 2022 8:54 AM I78300 AUG 19, 2022 8:54 AM I78F00 AUG 19, 2022 8:54 AM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSURE Q 1:87 REG UNL 0 PSI Q 2:92 PREM UNL 0 PSI Q 3: 0 PSI I78700 AUG 19, 2022 8:54 AM PRESSURE LLD SETUP REPORT Q 1:87 REG UNL LIQUID SENSOR ALMS L 2:FUEL ALARM L 5:FUEL ALARM L 8:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 2:92 PREM UNL LIQUID SENSOR ALMS L 2:FUEL ALARM L 5:FUEL ALARM L 8:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD SETUP WARN ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 3: - NO ALARM ASSIGNMENTS - I70200 AUG 19, 2022 8:54 AM LIQUID LABEL DEVICE LABEL 1 87 REG UNL ANNULAR 2 87 REG UNL STP 3 87 REG UNL FILL S 4 87 REG UNL 2 ANNULAR 5 87 REG UNL 2 SYPHON 6 87 REG UNL M FILL 7 87 REG UNL 3 ANNULAR 8 87 REG UNL 3 SYPHON 9 87 REG UNL N FILL 10 91 PREM UNL ANNULAR 11 91 PEM UNL FILL 12 91 PREM UNL STP 13 DIRP 1-2 14 DISP 3-4 15 DISP 5-6 16 DISP 7-8 17 DISP 9-10 18 DISP 11-12 19 20 21 22 23 24 I70300 AUG 19, 2022 8:54 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 REG UNL ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 REG UNL STP TRI-STATE (SINGLE FLOAT) 3 87 REG UNL FILL S TRI-STATE (SINGLE FLOAT) 4 87 REG UNL 2 ANNULAR TRI-STATE (SINGLE FLOAT) 5 87 REG UNL 2 SYPHON TRI-STATE (SINGLE FLOAT) 6 87 REG UNL M FILL TRI-STATE (SINGLE FLOAT) 7 87 REG UNL 3 ANNULAR TRI-STATE (SINGLE FLOAT) 8 87 REG UNL 3 SYPHON TRI-STATE (SINGLE FLOAT) 9 87 REG UNL N FILL TRI-STATE (SINGLE FLOAT) 10 91 PREM UNL ANNULAR TRI-STATE (SINGLE FLOAT) 11 91 PEM UNL FILL TRI-STATE (SINGLE FLOAT) 12 91 PREM UNL STP TRI-STATE (SINGLE FLOAT) 13 DIRP 1-2 TRI-STATE (SINGLE FLOAT) 14 DISP 3-4 TRI-STATE (SINGLE FLOAT) 15 DISP 5-6 TRI-STATE (SINGLE FLOAT) 16 DISP 7-8 TRI-STATE (SINGLE FLOAT) 17 DISP 9-10 TRI-STATE (SINGLE FLOAT) 18 DISP 11-12 TRI-STATE (SINGLE FLOAT) 19 TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 AUG 19, 2022 8:54 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87 REG UNL ANNULAR ANNULAR SPACE 2 87 REG UNL STP STP SUMP 3 87 REG UNL FILL S PIPING SUMP 4 87 REG UNL 2 ANNULAR ANNULAR SPACE 5 87 REG UNL 2 SYPHON STP SUMP 6 87 REG UNL M FILL PIPING SUMP 7 87 REG UNL 3 ANNULAR ANNULAR SPACE 8 87 REG UNL 3 SYPHON PIPING SUMP 9 87 REG UNL N FILL PIPING SUMP 10 91 PREM UNL ANNULAR ANNULAR SPACE 11 91 PEM UNL FILL STP SUMP 12 91 PREM UNL STP PIPING SUMP 13 DIRP 1-2 DISPENSER PAN 14 DISP 3-4 DISPENSER PAN 15 DISP 5-6 DISPENSER PAN 16 DISP 7-8 DISPENSER PAN 17 DISP 9-10 DISPENSER PAN 18 DISP 11-12 DISPENSER PAN 19 OTHER SENSORS 20 OTHER SENSORS 21 OTHER SENSORS 22 OTHER SENSORS 23 OTHER SENSORS 24 OTHER SENSORS I74200 AUG 19, 2022 8:54 AM I74300 AUG 19, 2022 8:54 AM I74400 AUG 19, 2022 8:54 AM I74700 AUG 19, 2022 8:54 AM I74800 AUG 19, 2022 8:54 AM I74900 AUG 19, 2022 8:54 AM I7BC00 AUG 19, 2022 8:54 AM I80200 AUG 19, 2022 8:54 AM I80300 AUG 19, 2022 8:54 AM I80400 AUG 19, 2022 8:54 AM I80700 AUG 19, 2022 8:54 AM RELAY LABEL DEVICE LABEL 1 2 3 ALARM 4 I80900 AUG 19, 2022 8:54 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 NORMALLY OPEN 2 NORMALLY OPEN 3 ALARM NORMALLY OPEN 4 NORMALLY OPEN I80B00 AUG 19, 2022 8:54 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 NONE 2 NONE 3 ALARM NONE 4 NONE I80A00 AUG 19, 2022 8:54 AM RELAY TYPE RELAY DESIGNATION TYPE 1 STANDARD 2 STANDARD 3 ALARM STANDARD 4 STANDARD I80C00 AUG 19, 2022 8:54 AM I80800 AUG 19, 2022 8:54 AM RELAY SETUP REPORT R 1: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 3:ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 AUG 19, 2022 8:55 AM EDIM:1 VR:349866-001-E TD:19.10.30.16.33 I79100 AUG 19, 2022 8:55 AM I72300 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DIS 1-2 AIR FLOW METER 02 DIS 3-4 AIR FLOW METER 03 DIS 5-6 AIR FLOW METER 04 DIS 7-8 AIR FLOW METER 05 DIS 9-10 AIR FLOW METER 06 DIS 11-12 AIR FLOW METER 07 VAPOR PRESS SENSOR VAPOR PRESSURE 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 EVR/ISD SETUP TYPE: BALANCE IV4F00 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 VAPOR PROCESSOR TYPE NONE IV4700 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 ASSESSMENT TIME START TIME: 11:59 PM TIME DELAY MINUTES: 1 IV5200 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 ACCEPT HIGH ORVR: NO IV4A00 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 00 01 01 UU BLEND3 02 01 02 01 UU BLEND3 03 02 03 02 UU BLEND3 04 03 04 02 UU BLEND3 05 04 05 03 UU BLEND3 06 05 06 03 UU BLEND3 07 06 07 04 UU BLEND3 08 07 08 04 UU BLEND3 09 08 09 05 UU BLEND3 10 09 10 05 UU BLEND3 11 10 11 06 UU BLEND3 12 11 12 06 UU BLEND3 IV4B00 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 00 01 00/01 03/01 09/01 xx/xx 01 01 00/02 03/02 09/02 xx/xx 02 02 00/03 03/03 09/03 xx/xx 03 02 00/04 03/04 09/04 xx/xx 04 03 00/05 03/05 09/05 xx/xx 05 03 00/06 03/06 09/06 xx/xx 06 04 00/07 03/07 09/07 xx/xx 07 04 00/08 03/08 09/08 xx/xx 08 05 00/09 03/09 09/09 xx/xx 09 05 00/10 03/10 09/10 xx/xx 10 06 00/11 03/11 09/11 xx/xx 11 06 00/12 03/12 09/12 xx/xx IV4900 AUG 19, 2022 8:55 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 19, 2022 8:55 AM ISD VERSION: 01.05 Grand Ave Alarm History Responses Received: I10200 AUG 19, 2022 8:56 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 INTERSTITIAL BD 203872 204303 2 INTERSTITIAL BD 203464 203819 3 INTERSTITIAL BD 203153 203310 4 PLLD SENSOR BD 3932 3952 5 4 PROBE / G.T. 165488 165770 6 8SMARTSENSOR BD 40245 40268 7 UNUSED 9801818 9704645 8 UNUSED 9790023 9690081 9 RELAY BOARD 15068 15100 10 PLLD POWER BD 101943 102061 11 UNUSED 9799782 9700603 12 UNUSED 9788700 9683577 13 UNUSED 9786792 9694332 14 UNUSED 9794241 9709175 15 UNUSED 9788884 9686411 16 UNUSED 9778883 9685017 COMM 1 ELEC DISP INT. 102717 102915 COMM 2 RS232 SERIAL BD 15091 15123 COMM 3 SERIAL SAT BD 488929 489474 COMM 4 UNUSED 9790264 9704366 COMM 5 RS485 SERIAL BD 69401 69554 COMM 6 RS232 SERIAL BD 15114 15146 I90200 AUG 19, 2022 8:57 AM SOFTWARE REVISION LEVEL VERSION 336.01 SOFTWARE# 346336-100-B CREATED - 20.04.26.20.30 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 7-19-22 3:29AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 7-19-22 3:05AM E 1 OTHER G COMMUNICATION ALARM CLEAR 7-16-22 2:16AM E 1 OTHER G COMMUNICATION ALARM ALARM 7-16-22 2:15AM E 1 OTHER G COMMUNICATION ALARM CLEAR 7-14-22 5:29AM E 1 OTHER G COMMUNICATION ALARM ALARM 7-14-22 5:22AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 7-14-22 2:58AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 7-14-22 1:09AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 7-14-22 12:46AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 7-14-22 12:35AM E 1 OTHER G COMMUNICATION ALARM CLEAR 7-09-22 5:54AM E 1 OTHER G COMMUNICATION ALARM ALARM 7-09-22 5:42AM E 1 OTHER G COMMUNICATION ALARM CLEAR 7-03-22 6:13AM E 1 OTHER G COMMUNICATION ALARM ALARM 7-03-22 6:13AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 7-02-22 3:11AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 7-02-22 3:06AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 6-30-22 3:00AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 6-30-22 1:55AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 6-30-22 1:33AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 6-30-22 1:08AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 6-27-22 11:32PM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 6-27-22 11:30PM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 6-16-22 12:13AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 6-15-22 11:52PM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 6-10-22 12:43AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 6-10-22 12:35AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 6-09-22 11:51PM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 6-09-22 11:27PM L 6 PIPE 87 REG UNL M FILL FUEL ALARM CLEAR 5-23-22 8:56AM E 1 OTHER G COMMUNICATION ALARM CLEAR 5-21-22 11:21PM E 1 OTHER G COMMUNICATION ALARM ALARM 5-21-22 11:16PM L 3 PIPE 87 REG UNL FILL S FUEL ALARM CLEAR 5-12-22 7:36PM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 5-12-22 4:07AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 5-12-22 4:03AM E 1 OTHER G COMMUNICATION ALARM CLEAR 5-07-22 3:34AM E 1 OTHER G COMMUNICATION ALARM ALARM 5-07-22 3:33AM E 1 OTHER G COMMUNICATION ALARM CLEAR 5-07-22 3:29AM E 1 OTHER G COMMUNICATION ALARM ALARM 5-07-22 3:27AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM CLEAR 5-03-22 2:18AM T 1 TANK UNLEADED 1 SUDDEN LOSS ALARM ALARM 5-03-22 1:34AM T 1 TANK UNLEADED 1 LOW PRODUCT ALARM CLEAR 5-03-22 12:49AM T 1 TANK UNLEADED 1 LOW PRODUCT ALARM ALARM 5-02-22 6:19PM E 1 OTHER G COMMUNICATION ALARM CLEAR 4-28-22 5:28AM E 1 OTHER G COMMUNICATION ALARM ALARM 4-28-22 5:27AM L 3 PIPE 87 REG UNL FILL S FUEL ALARM ALARM 4-22-22 10:00PM L 6 PIPE 87 REG UNL M FILL FUEL ALARM ALARM 4-22-22 1:09PM Q 2 OTHER 92 PREM UNL PLLD SHUTDOWN ALARM CLEAR 4-22-22 6:28AM Q 1 OTHER 87 REG UNL PLLD SHUTDOWN ALARM CLEAR 4-22-22 6:28AM L 5 STP SUMP 87 REG UNL 2 SYPHON FUEL ALARM CLEAR 4-22-22 6:28AM E 1 OTHER G COMMUNICATION ALARM CLEAR 4-22-22 4:59AM I11200 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED ALARM 8-19-22 8:15AM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 8-18-22 8:10PM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-18-22 3:31PM T 1 TANK UNLEADED 1 DELIVERY NEEDED CLEAR 8-16-22 12:02PM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 8-16-22 9:38AM SYSTEM PRINTER ERROR CLEAR 8-15-22 1:24PM SYSTEM PAPER OUT CLEAR 8-15-22 1:24PM SYSTEM PRINTER ERROR ALARM 8-15-22 1:22PM SYSTEM PAPER OUT ALARM 8-15-22 1:22PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-12-22 4:45PM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-10-22 7:37PM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED CLEAR 8-08-22 1:46PM T 1 TANK UNLEADED 1 DELIVERY NEEDED CLEAR 8-08-22 1:38PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-08-22 1:37PM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED ALARM 8-08-22 11:39AM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 8-08-22 6:41AM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-06-22 11:37PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-05-22 10:55AM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-04-22 10:04AM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-02-22 11:49PM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-01-22 12:01PM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED CLEAR 8-01-22 11:59AM T 1 TANK UNLEADED 1 DELIVERY NEEDED CLEAR 8-01-22 11:54AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:46AM SYSTEM PAPER OUT CLEAR 8-01-22 11:46AM SYSTEM PAPER OUT ALARM 8-01-22 11:45AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:45AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT CLEAR 8-01-22 11:44AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:44AM SYSTEM PAPER OUT ALARM 8-01-22 11:44AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT CLEAR 8-01-22 11:44AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:44AM SYSTEM PAPER OUT ALARM 8-01-22 11:44AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT ALARM 8-01-22 11:44AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:43AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:43AM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED ALARM 8-01-22 10:00AM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 7-31-22 10:02PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 7-31-22 1:51AM SYSTEM PRINTER ERROR ALARM 7-31-22 1:45AM SYSTEM PRINTER ERROR CLEAR 7-31-22 1:45AM SYSTEM PRINTER ERROR ALARM 7-31-22 1:45AM SYSTEM PRINTER ERROR CLEAR 7-31-22 1:44AM SYSTEM PAPER OUT CLEAR 7-31-22 1:44AM SYSTEM PAPER OUT ALARM 7-31-22 1:44AM SYSTEM PRINTER ERROR ALARM 7-31-22 1:44AM I20600 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 TANK ALARM HISTORY TANK 1 UNLEADED 1 SETUP DATA WARNING MAR 24, 2021 9:18 AM LOW PRODUCT ALARM MAY 2, 2022 6:19 PM SUDDEN LOSS ALARM JUL 19, 2022 3:05 AM JUL 14, 2022 1:09 AM JUL 14, 2022 12:35 AM HIGH PRODUCT ALARM MAR 24, 2021 9:18 AM DELIVERY NEEDED AUG 18, 2022 8:10 PM AUG 16, 2022 9:38 AM AUG 8, 2022 6:41 AM TANK 2 UNLEADED 2 TURBN SETUP DATA WARNING MAR 24, 2021 9:20 AM HIGH PRODUCT ALARM MAR 24, 2021 9:20 AM DELIVERY NEEDED AUG 19, 2022 8:15 AM AUG 8, 2022 11:39 AM AUG 1, 2022 10:00 AM TANK 3 UNLEADED 3 SETUP DATA WARNING MAR 24, 2021 9:22 AM HIGH PRODUCT ALARM MAR 24, 2021 9:22 AM DELIVERY NEEDED JUL 16, 2022 8:06 PM MAY 2, 2022 11:46 AM JAN 24, 2022 1:02 PM TANK 4 PREMIUM SETUP DATA WARNING MAR 24, 2021 9:24 AM HIGH PRODUCT ALARM MAR 24, 2021 9:24 AM DELIVERY NEEDED AUG 18, 2022 3:31 PM AUG 10, 2022 7:37 PM AUG 6, 2022 11:37 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:87 REG UNL APR 22, 2022 2:00 AM PLLD SHUTDOWN ALARM MAR 20, 2022 6:52 AM PLLD SHUTDOWN ALARM MAR 13, 2022 3:56 AM PLLD SHUTDOWN ALARM MAR 4, 2022 3:21 AM PLLD SHUTDOWN ALARM FEB 9, 2022 11:53 PM PLLD SHUTDOWN ALARM DEC 27, 2021 1:57 PM PLLD SHUTDOWN ALARM DEC 24, 2021 2:26 AM PLLD SHUTDOWN ALARM DEC 23, 2021 6:15 PM PLLD SHUTDOWN ALARM DEC 22, 2021 8:29 PM PLLD SHUTDOWN ALARM AUG 24, 2021 10:44 AM PLLD SHUTDOWN ALARM Q 2:92 PREM UNL APR 22, 2022 2:00 AM PLLD SHUTDOWN ALARM MAR 20, 2022 6:52 AM PLLD SHUTDOWN ALARM MAR 13, 2022 3:56 AM PLLD SHUTDOWN ALARM MAR 4, 2022 3:21 AM PLLD SHUTDOWN ALARM FEB 9, 2022 11:53 PM PLLD SHUTDOWN ALARM DEC 27, 2021 1:57 PM PLLD SHUTDOWN ALARM DEC 24, 2021 2:26 AM PLLD SHUTDOWN ALARM DEC 23, 2021 6:15 PM PLLD SHUTDOWN ALARM DEC 22, 2021 8:29 PM PLLD SHUTDOWN ALARM AUG 24, 2021 11:13 AM PLLD SHUTDOWN ALARM I30200 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 REG UNL ANNULAR AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 10:02 AM FUEL ALARM AUG 24, 2021 9:47 AM FUEL ALARM 2 87 REG UNL STP MAR 13, 2022 3:56 AM SENSOR OUT ALARM DEC 23, 2021 7:00 PM SENSOR OUT ALARM DEC 23, 2021 6:34 PM SENSOR OUT ALARM 3 87 REG UNL FILL S APR 22, 2022 10:00 PM FUEL ALARM MAR 28, 2022 9:38 AM FUEL ALARM MAR 4, 2022 3:24 AM FUEL ALARM 4 87 REG UNL 2 ANNULAR DEC 23, 2021 6:35 PM SENSOR OUT ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:45 AM FUEL ALARM 5 87 REG UNL 2 SYPHON APR 22, 2022 2:00 AM FUEL ALARM MAR 20, 2022 6:52 AM FUEL ALARM MAR 4, 2022 3:21 AM FUEL ALARM 6 87 REG UNL M FILL APR 22, 2022 1:09 PM FUEL ALARM MAR 20, 2022 2:12 PM FUEL ALARM DEC 15, 2021 10:32 AM FUEL ALARM 7 87 REG UNL 3 ANNULAR DEC 22, 2021 8:58 PM SENSOR OUT ALARM AUG 24, 2021 10:08 AM SENSOR OUT ALARM AUG 24, 2021 9:43 AM FUEL ALARM 8 87 REG UNL 3 SYPHON DEC 23, 2021 6:20 PM SENSOR OUT ALARM AUG 24, 2021 10:08 AM SENSOR OUT ALARM AUG 24, 2021 9:40 AM FUEL ALARM 9 87 REG UNL N FILL DEC 14, 2021 12:03 PM FUEL ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:48 AM FUEL ALARM 10 91 PREM UNL ANNULAR DEC 23, 2021 6:32 PM SENSOR OUT ALARM DEC 22, 2021 8:58 PM SENSOR OUT ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM 11 91 PEM UNL FILL JAN 19, 2022 3:54 PM FUEL ALARM JAN 8, 2022 2:24 AM FUEL ALARM JAN 8, 2022 1:53 AM FUEL ALARM 12 91 PREM UNL STP AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:41 AM FUEL ALARM MAR 24, 2021 9:15 AM FUEL ALARM 13 DIRP 1-2 AUG 24, 2021 10:08 AM SENSOR OUT ALARM AUG 24, 2021 9:50 AM FUEL ALARM MAR 24, 2021 9:16 AM FUEL ALARM 14 DISP 3-4 AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:50 AM FUEL ALARM MAR 24, 2021 9:16 AM FUEL ALARM 15 DISP 5-6 DEC 23, 2021 6:39 PM SENSOR OUT ALARM DEC 23, 2021 6:36 PM SENSOR OUT ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM 16 DISP 7-8 AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:52 AM FUEL ALARM MAR 24, 2021 9:16 AM FUEL ALARM 17 DISP 9-10 AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:53 AM FUEL ALARM MAR 24, 2021 9:16 AM FUEL ALARM 18 DISP 11-12 AUG 24, 2021 10:09 AM SENSOR OUT ALARM AUG 24, 2021 9:54 AM FUEL ALARM MAR 24, 2021 9:16 AM FUEL ALARM I31600 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DIS 1-2 2 DIS 3-4 3 DIS 5-6 4 DIS 7-8 5 DIS 9-10 6 DIS 11-12 7 VAPOR PRESS SENSOR I40200 AUG 19, 2022 8:57 AM I40300 AUG 19, 2022 8:57 AM I34200 AUG 19, 2022 8:57 AM I34700 AUG 19, 2022 8:57 AM IV0100 AUG 19, 2022 8:57 AM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-01-30 00:02:58 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.08 21-11-10 00:03:07 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 21-11-09 00:03:13 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.86 21-09-04 00:02:55 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:DIS 1-2 21-05-14 00:01:53 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.94 21-05-13 00:01:52 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.81 21-05-12 00:02:00 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.94 21-05-11 00:01:57 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.81 21-05-10 00:02:07 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.64 21-05-09 00:02:07 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.66 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-06-17 00:02:08 READINESS ISD:PP EVR:PP ISD & EVR READY 22-06-16 10:46:28 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-06-16 10:46:28 ISD STARTUP 22-06-16 10:46:11 ISD SHUTDOWN 22-04-25 13:16:00 TIME CHANGE DETECTED AT: 22-04-25 14:16:15 22-04-03 03:00:00 TIME CHANGE DETECTED AT: 22-04-03 02:00:13 22-03-28 13:35:00 TIME CHANGE DETECTED AT: 22-03-28 12:33:32 22-02-05 00:02:13 READINESS ISD:PP EVR:PP ISD & EVR READY 22-02-04 00:02:10 READINESS ISD:PP EVR:NP EVR READINESS PENDING 22-02-03 00:02:11 READINESS ISD:PP EVR:NP EVR READINESS PENDING Grand Ave Alarm History After Responses Received: I10200 AUG 19, 2022 12:49 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 INTERSTITIAL BD 203872 203302 2 INTERSTITIAL BD 203464 203302 3 INTERSTITIAL BD 203153 202771 4 PLLD SENSOR BD 3932 3947 5 4 PROBE / G.T. 165488 164990 6 8SMARTSENSOR BD 40245 40146 7 UNUSED 9801818 9674786 8 UNUSED 9790023 9655765 9 RELAY BOARD 15068 15045 10 PLLD POWER BD 101943 101759 11 UNUSED 9799782 9641473 12 UNUSED 9788700 9648748 13 UNUSED 9786792 9648979 14 UNUSED 9794241 9647404 15 UNUSED 9788884 9647566 16 UNUSED 9778883 9645967 COMM 1 ELEC DISP INT. 102717 102516 COMM 2 RS232 SERIAL BD 15091 15092 COMM 3 SERIAL SAT BD 488929 487992 COMM 4 UNUSED 9790264 9638137 COMM 5 RS485 SERIAL BD 69401 69242 COMM 6 RS232 SERIAL BD 15114 15092 I90200 AUG 19, 2022 12:49 PM SOFTWARE REVISION LEVEL VERSION 336.01 SOFTWARE# 346336-100-B CREATED - 20.04.26.20.30 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 19, 2022 12:49 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 3 PIPE 87 REG UNL FILL S FUEL ALARM CLEAR 8-19-22 12:47PM L 3 PIPE 87 REG UNL FILL S FUEL ALARM ALARM 8-19-22 12:37PM Q 2 OTHER 92 PREM UNL PLLD SHUTDOWN ALARM CLEAR 8-19-22 11:52AM Q 2 OTHER 92 PREM UNL GROSS LINE FAIL CLEAR 8-19-22 11:52AM Q 1 OTHER 87 REG UNL PLLD SHUTDOWN ALARM CLEAR 8-19-22 11:52AM Q 1 OTHER 87 REG UNL GROSS LINE FAIL CLEAR 8-19-22 11:52AM Q 1 OTHER 87 REG UNL PLLD SHUTDOWN ALARM ALARM 8-19-22 11:29AM Q 1 OTHER 87 REG UNL GROSS LINE FAIL ALARM 8-19-22 11:29AM Q 2 OTHER 92 PREM UNL PLLD SHUTDOWN ALARM ALARM 8-19-22 10:20AM Q 2 OTHER 92 PREM UNL GROSS LINE FAIL ALARM 8-19-22 10:20AM Q 2 OTHER 92 PREM UNL PLLD SHUTDOWN ALARM CLEAR 8-19-22 10:12AM Q 1 OTHER 87 REG UNL PLLD SHUTDOWN ALARM CLEAR 8-19-22 10:12AM L16 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-19-22 10:12AM L16 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-19-22 9:59AM Q 2 OTHER 92 PREM UNL PLLD SHUTDOWN ALARM ALARM 8-19-22 9:59AM Q 1 OTHER 87 REG UNL PLLD SHUTDOWN ALARM ALARM 8-19-22 9:59AM Q 2 OTHER 92 PREM UNL PLLD SHUTDOWN ALARM CLEAR 8-19-22 9:56AM Q 1 OTHER 87 REG UNL PLLD SHUTDOWN ALARM CLEAR 8-19-22 9:56AM L 4 ANNULAR 87 REG UNL 2 ANNULAR SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 3 PIPE 87 REG UNL FILL S SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 2 STP SUMP 87 REG UNL STP SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 1 ANNULAR 87 REG UNL ANNULAR SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 8 PIPE 87 REG UNL 3 SYPHON SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 7 ANNULAR 87 REG UNL 3 ANNULAR SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 6 PIPE 87 REG UNL M FILL SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 5 STP SUMP 87 REG UNL 2 SYPHON SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L12 PIPE 91 PREM UNL STP SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L11 STP SUMP 91 PEM UNL FILL SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L10 ANNULAR 91 PREM UNL ANNULAR SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L14 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L 9 PIPE 87 REG UNL N FILL SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L16 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L15 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L13 DISP PAN DIRP 1-2 SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 8-19-22 9:56AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 8-19-22 9:55AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 8-19-22 9:55AM L12 PIPE 91 PREM UNL STP SENSOR OUT ALARM ALARM 8-19-22 9:55AM L11 STP SUMP 91 PEM UNL FILL SENSOR OUT ALARM ALARM 8-19-22 9:55AM L10 ANNULAR 91 PREM UNL ANNULAR SENSOR OUT ALARM ALARM 8-19-22 9:55AM L16 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-19-22 9:55AM L15 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-19-22 9:55AM L14 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-19-22 9:55AM L13 DISP PAN DIRP 1-2 SENSOR OUT ALARM ALARM 8-19-22 9:55AM L 9 PIPE 87 REG UNL N FILL SENSOR OUT ALARM ALARM 8-19-22 9:55AM L 4 ANNULAR 87 REG UNL 2 ANNULAR SENSOR OUT ALARM ALARM 8-19-22 9:55AM L 3 PIPE 87 REG UNL FILL S SENSOR OUT ALARM ALARM 8-19-22 9:55AM L 2 STP SUMP 87 REG UNL STP SENSOR OUT ALARM ALARM 8-19-22 9:55AM L 8 PIPE 87 REG UNL 3 SYPHON SENSOR OUT ALARM ALARM 8-19-22 9:55AM I11200 AUG 19, 2022 12:50 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 8-19-22 9:00AM SYSTEM PAPER OUT CLEAR 8-19-22 9:00AM SYSTEM PRINTER ERROR ALARM 8-19-22 8:59AM SYSTEM PAPER OUT ALARM 8-19-22 8:59AM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED ALARM 8-19-22 8:15AM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 8-18-22 8:10PM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-18-22 3:31PM T 1 TANK UNLEADED 1 DELIVERY NEEDED CLEAR 8-16-22 12:02PM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 8-16-22 9:38AM SYSTEM PRINTER ERROR CLEAR 8-15-22 1:24PM SYSTEM PAPER OUT CLEAR 8-15-22 1:24PM SYSTEM PRINTER ERROR ALARM 8-15-22 1:22PM SYSTEM PAPER OUT ALARM 8-15-22 1:22PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-12-22 4:45PM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-10-22 7:37PM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED CLEAR 8-08-22 1:46PM T 1 TANK UNLEADED 1 DELIVERY NEEDED CLEAR 8-08-22 1:38PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-08-22 1:37PM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED ALARM 8-08-22 11:39AM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 8-08-22 6:41AM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-06-22 11:37PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-05-22 10:55AM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-04-22 10:04AM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 8-02-22 11:49PM T 4 TANK PREMIUM DELIVERY NEEDED ALARM 8-01-22 12:01PM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED CLEAR 8-01-22 11:59AM T 1 TANK UNLEADED 1 DELIVERY NEEDED CLEAR 8-01-22 11:54AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:46AM SYSTEM PAPER OUT CLEAR 8-01-22 11:46AM SYSTEM PAPER OUT ALARM 8-01-22 11:45AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:45AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT CLEAR 8-01-22 11:44AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:44AM SYSTEM PAPER OUT ALARM 8-01-22 11:44AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT CLEAR 8-01-22 11:44AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:44AM SYSTEM PAPER OUT ALARM 8-01-22 11:44AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT CLEAR 8-01-22 11:44AM SYSTEM PAPER OUT ALARM 8-01-22 11:44AM SYSTEM PRINTER ERROR ALARM 8-01-22 11:43AM SYSTEM PRINTER ERROR CLEAR 8-01-22 11:43AM T 2 TANK UNLEADED 2 TURBN DELIVERY NEEDED ALARM 8-01-22 10:00AM T 1 TANK UNLEADED 1 DELIVERY NEEDED ALARM 7-31-22 10:02PM T 4 TANK PREMIUM DELIVERY NEEDED CLEAR 7-31-22 1:51AM SYSTEM PRINTER ERROR ALARM 7-31-22 1:45AM SYSTEM PRINTER ERROR CLEAR 7-31-22 1:45AM SYSTEM PRINTER ERROR ALARM 7-31-22 1:45AM I20600 AUG 19, 2022 12:50 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 TANK ALARM HISTORY TANK 1 UNLEADED 1 SETUP DATA WARNING MAR 24, 2021 9:18 AM LOW PRODUCT ALARM MAY 2, 2022 6:19 PM SUDDEN LOSS ALARM JUL 19, 2022 3:05 AM JUL 14, 2022 1:09 AM JUL 14, 2022 12:35 AM HIGH PRODUCT ALARM MAR 24, 2021 9:18 AM DELIVERY NEEDED AUG 18, 2022 8:10 PM AUG 16, 2022 9:38 AM AUG 8, 2022 6:41 AM TANK 2 UNLEADED 2 TURBN SETUP DATA WARNING MAR 24, 2021 9:20 AM HIGH PRODUCT ALARM MAR 24, 2021 9:20 AM DELIVERY NEEDED AUG 19, 2022 8:15 AM AUG 8, 2022 11:39 AM AUG 1, 2022 10:00 AM TANK 3 UNLEADED 3 SETUP DATA WARNING MAR 24, 2021 9:22 AM HIGH PRODUCT ALARM MAR 24, 2021 9:22 AM DELIVERY NEEDED JUL 16, 2022 8:06 PM MAY 2, 2022 11:46 AM JAN 24, 2022 1:02 PM TANK 4 PREMIUM SETUP DATA WARNING MAR 24, 2021 9:24 AM HIGH PRODUCT ALARM MAR 24, 2021 9:24 AM DELIVERY NEEDED AUG 18, 2022 3:31 PM AUG 10, 2022 7:37 PM AUG 6, 2022 11:37 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 19, 2022 12:50 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:87 REG UNL AUG 19, 2022 11:29 AM PLLD SHUTDOWN ALARM AUG 19, 2022 11:29 AM GROSS LINE FAIL AUG 19, 2022 9:59 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:55 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:52 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:52 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:51 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:50 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:49 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:49 AM PLLD SHUTDOWN ALARM Q 2:92 PREM UNL AUG 19, 2022 10:20 AM PLLD SHUTDOWN ALARM AUG 19, 2022 10:20 AM GROSS LINE FAIL AUG 19, 2022 9:59 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:55 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:52 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:52 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:51 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:50 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:49 AM PLLD SHUTDOWN ALARM AUG 19, 2022 9:49 AM PLLD SHUTDOWN ALARM I30200 AUG 19, 2022 12:50 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 REG UNL ANNULAR AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:35 AM FUEL ALARM AUG 19, 2022 9:35 AM FUEL ALARM 2 87 REG UNL STP AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:29 AM FUEL ALARM MAR 13, 2022 3:56 AM SENSOR OUT ALARM 3 87 REG UNL FILL S AUG 19, 2022 12:37 PM FUEL ALARM AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:33 AM FUEL ALARM 4 87 REG UNL 2 ANNULAR AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:47 AM FUEL ALARM AUG 19, 2022 9:40 AM FUEL ALARM 5 87 REG UNL 2 SYPHON AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:30 AM FUEL ALARM APR 22, 2022 2:00 AM FUEL ALARM 6 87 REG UNL M FILL AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:32 AM FUEL ALARM APR 22, 2022 1:09 PM FUEL ALARM 7 87 REG UNL 3 ANNULAR AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:40 AM FUEL ALARM AUG 19, 2022 9:37 AM FUEL ALARM 8 87 REG UNL 3 SYPHON AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:30 AM FUEL ALARM DEC 23, 2021 6:20 PM SENSOR OUT ALARM 9 87 REG UNL N FILL AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:32 AM FUEL ALARM DEC 14, 2021 12:03 PM FUEL ALARM 10 91 PREM UNL ANNULAR AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:46 AM FUEL ALARM AUG 19, 2022 9:43 AM FUEL ALARM 11 91 PEM UNL FILL AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:31 AM FUEL ALARM JAN 19, 2022 3:54 PM FUEL ALARM 12 91 PREM UNL STP AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:30 AM FUEL ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM 13 DIRP 1-2 AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:52 AM FUEL ALARM AUG 24, 2021 10:08 AM SENSOR OUT ALARM 14 DISP 3-4 AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:52 AM FUEL ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM 15 DISP 5-6 AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:50 AM FUEL ALARM DEC 23, 2021 6:39 PM SENSOR OUT ALARM 16 DISP 7-8 AUG 19, 2022 9:59 AM FUEL ALARM AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:51 AM FUEL ALARM 17 DISP 9-10 AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:49 AM FUEL ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM 18 DISP 11-12 AUG 19, 2022 9:55 AM SENSOR OUT ALARM AUG 19, 2022 9:49 AM FUEL ALARM AUG 24, 2021 10:09 AM SENSOR OUT ALARM I31600 AUG 19, 2022 12:50 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DIS 1-2 2 DIS 3-4 3 DIS 5-6 4 DIS 7-8 5 DIS 9-10 6 DIS 11-12 7 VAPOR PRESS SENSOR I40200 AUG 19, 2022 12:50 PM I40300 AUG 19, 2022 12:50 PM I34200 AUG 19, 2022 12:50 PM I34700 AUG 19, 2022 12:50 PM IV0100 AUG 19, 2022 12:50 PM 243508 ARCO AM-PM 4203 MING AVE BAKERSFIELD CA. 661-834-1076 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-01-30 00:02:58 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.08 21-11-10 00:03:07 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 21-11-09 00:03:13 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.86 21-09-04 00:02:55 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:DIS 1-2 21-05-14 00:01:53 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.94 21-05-13 00:01:52 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.81 21-05-12 00:02:00 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.94 21-05-11 00:01:57 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.81 21-05-10 00:02:07 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.64 21-05-09 00:02:07 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.66 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-08-19 09:54:16 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-08-19 09:54:16 ISD STARTUP 22-08-19 09:54:04 ISD SHUTDOWN 22-06-17 00:02:08 READINESS ISD:PP EVR:PP ISD & EVR READY 22-06-16 10:46:28 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-06-16 10:46:28 ISD STARTUP 22-06-16 10:46:11 ISD SHUTDOWN 22-04-25 13:16:00 TIME CHANGE DETECTED AT: 22-04-25 14:16:15 22-04-03 03:00:00 TIME CHANGE DETECTED AT: 22-04-03 02:00:13 22-03-28 13:35:00 TIME CHANGE DETECTED AT: 22-03-28 12:33:32