Loading...
HomeMy WebLinkAboutFMC 2022Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10155971 8/11/2022 Jaco #7773 Fastrip #31 3501 Mt. Vernon Avenue Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 Veeder Root B47853 7/31/2024 OPW 0148613 8/21/2024 8/11/2022 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 420 Unl Ann L2 420 Dsl Ann L3 Not used L4 208 Unl STP L5 208 Dsl STP L6 208 Prem STP L7 420 Prem Ann L8 Not used L9 208 Disp 1-2 L10 208 Disp 3-4 L11 208 Disp 5-6 L12 208 Disp 7-8 L13 208 Trans Sump Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V Unl T2 FX1DV Dsl T3 FX1V Prem Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. PARK I N G 175' EXIS T I N G B U I L D I N G NO PR I C E S I G N MOUNT VERNON AVE. UN I V E R S I T Y A V E . CATCHBASIN N 94. 2 ' 50' 1 1 7 . 5 ' 180' H STPL4 AL1 V F L11 G W PROPERTY LINE PRO P E R T Y L I N E L12 L9L10 DUM P S T E R L13 12,000 GALLONDIESEL 12,000 GALLONPREMIUM 40' S T O R A G E C O N T A I N E R 40' S T O R A G E C O N T A I N E R STPL5 AL2 V F STPL6 AL3 V F 12,000 GALLON87 UNL LEGEND L1 87 ANNULAR L2 DSL ANNULAR L3 91 ANNULAR L4 87 STP L5 DSL STP L6 91 STP L9 UDC 1 - 2 L10 UDC 3 - 4 L11 UDC 5 - 6 L12 UDC 7 - 8 L13 TRANS SUMP 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SITE MAP SITE PLAN C1 TAB:SITE PLAN 1"=10'-0" INCHES012 SHEET SIZE 22 X 34 DATE REVISIONS DATE: DRAWN BY: CHECKED: APPROVED: RAC FASTRIP - 7-773 CADFILE: SHEET NO.7773-MSP A.P.N.:382-020-16-00-8 SCALE: FASTRIP FOOD STORECONVENIENCE MARKET FOR: BAKERSFIELD, CALIFORNIA 93306 JAMIESON HILL 3501 MT VERNON AVE. 3101 STATE RDBAKERSFIELD, CA 93308 PROJECT OWNER: DRAWING: CD 10/13/2020 3501 MT VERNON AVE.BAKERSFIELD, CA 93306 M T V E R N O N A V E . UNIVERSITY AVE. PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-003018 CERS ID 10155971 FASTRIP #7773 3501 MT VERNON AVE. BAKERSFIELD, CA 93306 10/13/2020 REV. VICINITY MAP PROJECT DATA APPENDIX C-10 SH E A R V A L V E O P E R A T I O N I N S P E C T I O N )D F L O L W \  1 D P H  2Z Q H U $G G U H V V  $G G U H V V &L W \   6 W D W H   = L S  & R G H  &L W \   6 W D W H   = L S  & R G H  )D F L O L W \  ,  '     3K R Q H    7H V W L Q J  & R P S D Q \  3K R Q H    7K L V  G D W D  V K H H W  L V  I R U  L Q V S H F W L Q J  V K H D U  Y D O Y H V  O R F D W H G  L Q V L G H  G LV S H Q V H U V   6 H H  3 ( ,  5 3       6 H F W L R Q     I R U  W K H  L Q V S H F W L R Q  S U R F H G XU H  3U R G X F W  * U D G H 'L V S H Q V H U  , '      6K H D U  9 D O Y H 7 \ S H  3 U R G X F W  9 D S R U   , V  W K H  V K H D U  Y D O Y H  U L J L G O \  DQ F K R U H G  W R  W K H  G L V S H Q V H U  E R [  IU D P H  R U  G L V S H Q V H U  L V O D Q G " < H V    1 R < H V    1 R < H V    1 R < H V    1 R < H V    1 R < H V    1 R < H V    1 R <HV1R <HV1R   , V  W K H  V K H D U  V H F W L R Q  S R V L  WL R Q H G  E H W Z H H Q  ó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´ 1 R µ  W R  / L Q H V      R U  D  ´ < H V µ  I R U  / L Q H    L Q G L F D W H V  D  W H V W  I D L O XU H  Te s t R e s u l t s 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3 D V V    ) D L O 3DVV)DLO3DVV)DLO Co m m e n t s : 7H V W H U · V  1 D PH  BB B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B  7H V W H U · V  6 L J Q D W X U H  BB B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B 1Z H V W F R  / / &            Ja c o # 7 7 7 3 F a s t r i p # 3 1 35 0 1 M t . V e r n o n A v e n u e Ba k e r s f i e l d 10 1 5 5 9 7 1 3- 4 7- 8 MP D MP D MP D MP D 1- 2 5- 6 Pr o d u c t Pr o d u c t Pr o d u c t Pr o d u c t Aa r o n P e r r i g o Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10155971 8/11/2022 Jaco #7773 Fastrip #31 3501 Mt. Vernon Avenue Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 OPW 0148613 8/21/2024 Lake Test All 3 fill spill buckets 8/11/2022 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. Unl OPW Prem OPW Dsl OPW Jaco 7773 Setup Responses Received: 200 FASTRIP 773 3501 MT VERNON BAKERSFIELD CA AUG 11, 2022 9:11 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 8594 74.40 0.0 82.6 3468 2 DIESEL 7499 66.18 1.0 90.0 4563 3 PREMIUM 7982 69.76 0.0 90.2 4080 I90500 AUG 11, 2022 9:11 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 AUG 11, 2022 9:11 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 11, 2022 9:11 AM SHIFT TIME 1 : DISABLED I50202 AUG 11, 2022 9:11 AM SHIFT TIME 2 : DISABLED I50203 AUG 11, 2022 9:11 AM SHIFT TIME 3 : DISABLED I50204 AUG 11, 2022 9:11 AM SHIFT TIME 4 : DISABLED I54600 AUG 11, 2022 9:11 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 11, 2022 9:11 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 11, 2022 9:11 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 11, 2022 9:11 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 11, 2022 9:11 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 11, 2022 9:11 AM PRINT TC VOLUMES ENABLED I50E00 AUG 11, 2022 9:11 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 11, 2022 9:11 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 11, 2022 9:11 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 11, 2022 9:11 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 11, 2022 9:11 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 AUG 11, 2022 9:11 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 11, 2022 9:11 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 11, 2022 9:11 AM TANK CHART SECURITY DISABLED I5BD00 AUG 11, 2022 9:11 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 11, 2022 9:11 AM MASS/DENSITY DISABLED I88101 AUG 11, 2022 9:11 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 AUG 11, 2022 9:11 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 11, 2022 9:11 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 AUG 11, 2022 9:11 AM I88105 AUG 11, 2022 9:11 AM I88106 AUG 11, 2022 9:11 AM I52000 AUG 11, 2022 9:11 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE OCT 12, 2017 DISABLED 2 ON DATE OCT 12, 2017 DISABLED 3 ON DATE OCT 12, 2017 DISABLED 4 ON DATE OCT 12, 2017 DISABLED 5 ON DATE OCT 12, 2017 DISABLED 6 ON DATE OCT 12, 2017 DISABLED 7 ON DATE OCT 12, 2017 DISABLED 8 ON DATE OCT 12, 2017 DISABLED I60100 AUG 11, 2022 9:11 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 DIESEL ON 3 PREMIUM ON 4 OFF I60200 AUG 11, 2022 9:11 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 DIESEL 3 PREMIUM 4 I60300 AUG 11, 2022 9:11 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 DIESEL 2 3 PREMIUM 3 4 4 I60900 AUG 11, 2022 9:11 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 DIESEL 0.000450 3 PREMIUM 0.000700 4 0.000000 I60700 AUG 11, 2022 9:11 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.00 2 DIESEL 111.00 3 PREMIUM 111.00 4 0.00 I60A00 AUG 11, 2022 9:11 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12062 2 DIESEL 1 PT 12062 3 PREMIUM 1 PT 12062 4 1 PT 0 I60400 AUG 11, 2022 9:11 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 DIESEL 12062 3 PREMIUM 12062 4 0 I60500 AUG 11, 2022 9:11 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 2 DIESEL 12062 0 0 0 3 PREMIUM 12062 0 0 0 4 0 0 0 0 I60600 AUG 11, 2022 9:11 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 11, 2022 9:11 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 DIESEL NO 3 PREMIUM NO 4 NO I62F00 AUG 11, 2022 9:11 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 DIESEL 4.0 IN. 3 PREMIUM 4.0 IN. I62700 AUG 11, 2022 9:11 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 DIESEL 2.0 3 PREMIUM 2.0 I64200 AUG 11, 2022 9:11 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 DIESEL LOW 3 PREMIUM LOW I62400 AUG 11, 2022 9:11 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 DIESEL 3.0 3 PREMIUM 3.0 I62800 AUG 11, 2022 9:11 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 DIESEL 12062 3 PREMIUM 12062 4 0 I62300 AUG 11, 2022 9:11 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10856 2 DIESEL 10856 3 PREMIUM 10856 4 0 I62200 AUG 11, 2022 9:11 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11459 2 DIESEL 11459 3 PREMIUM 11459 4 0 I62900 AUG 11, 2022 9:11 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1809 2 DIESEL 1809 3 PREMIUM 1809 4 0 I62100 AUG 11, 2022 9:11 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 DIESEL 500 3 PREMIUM 500 4 0 I62600 AUG 11, 2022 9:11 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 DIESEL 99 3 PREMIUM 99 4 99 I62500 AUG 11, 2022 9:11 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 DIESEL 99 3 PREMIUM 99 4 99 I60800 AUG 11, 2022 9:11 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 DIESEL 0.00 3 PREMIUM 0.00 4 0.00 I60B00 AUG 11, 2022 9:11 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 11, 2022 9:11 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 DIESEL 0.00 3 PREMIUM 0.00 4 0.00 I61200 AUG 11, 2022 9:11 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 DIESEL NONE NONE 3 PREMIUM NONE NONE 4 NONE NONE I63600 AUG 11, 2022 9:11 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 DIESEL 120 3 PREMIUM 120 4 0 I62A00 AUG 11, 2022 9:11 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 DIESEL 120 3 PREMIUM 120 4 0 I62C00 AUG 11, 2022 9:11 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 DIESEL STANDARD 3 PREMIUM STANDARD 4 STANDARD I62D00 AUG 11, 2022 9:11 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 11, 2022 9:11 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 DIESEL OFF OFF 3 PREMIUM OFF OFF 4 OFF OFF I63000 AUG 11, 2022 9:11 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 DIESEL OFF 3 PREMIUM OFF 4 OFF I63200 AUG 11, 2022 9:11 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 DIESEL OFF 3 PREMIUM OFF 4 OFF I61000 AUG 11, 2022 9:11 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 DIESEL 1 3 PREMIUM 1 4 1 I63A00 AUG 11, 2022 9:11 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 DIESEL 10.00% 3 PREMIUM 10.00% 4 10.00% I61100 AUG 11, 2022 9:11 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK MAR 22, 2011 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 11, 2022 9:11 AM CSLD PROBABLITY OF DETECTION I61400 AUG 11, 2022 9:11 AM CSLD CLIMATE FACTOR I61600 AUG 11, 2022 9:11 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 DIESEL IMMEDIATE 3 PREMIUM IMMEDIATE 4 IMMEDIATE I61A00 AUG 11, 2022 9:11 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 DIESEL DISABLED 3 PREMIUM DISABLED 4 DISABLED I61B00 AUG 11, 2022 9:11 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 11, 2022 9:11 AM CSLD REPORT ONLY I62B00 AUG 11, 2022 9:11 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 DIESEL ??? 0, 0 3 PREMIUM ??? 0, 0 4 ??? 0, 0 I63300 AUG 11, 2022 9:11 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 11, 2022 9:11 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 DIESEL 0 3 PREMIUM 0 4 0 I63500 AUG 11, 2022 9:11 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 DIESEL 1 3 PREMIUM 1 4 1 I63900 AUG 11, 2022 9:11 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 END FACTOR: NONE I78000 AUG 11, 2022 9:11 AM I77700 AUG 11, 2022 9:11 AM I77800 AUG 11, 2022 9:11 AM I78C00 AUG 11, 2022 9:11 AM I78300 AUG 11, 2022 9:11 AM I78F00 AUG 11, 2022 9:11 AM I78700 AUG 11, 2022 9:11 AM I70200 AUG 11, 2022 9:11 AM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 DSL ANN 3 PNL ANM 4 UNL STP 5 DSL STP 6 PNL STP 7 PNL ANN 8 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUNP 14 15 16 I70300 AUG 11, 2022 9:11 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 DSL ANN TRI-STATE (SINGLE FLOAT) 3 PNL ANM TRI-STATE (SINGLE FLOAT) 4 UNL STP TRI-STATE (SINGLE FLOAT) 5 DSL STP TRI-STATE (SINGLE FLOAT) 6 PNL STP TRI-STATE (SINGLE FLOAT) 7 PNL ANN TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUNP TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 AUG 11, 2022 9:11 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 DSL ANN ANNULAR SPACE 3 PNL ANM ANNULAR SPACE 4 UNL STP STP SUMP 5 DSL STP STP SUMP 6 PNL STP STP SUMP 7 PNL ANN ANNULAR SPACE 8 OTHER SENSORS 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUNP PIPING SUMP 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 AUG 11, 2022 9:11 AM I74300 AUG 11, 2022 9:11 AM I74400 AUG 11, 2022 9:11 AM I74700 AUG 11, 2022 9:11 AM I74800 AUG 11, 2022 9:11 AM I74900 AUG 11, 2022 9:11 AM I7BC00 AUG 11, 2022 9:11 AM I80200 AUG 11, 2022 9:11 AM I80300 AUG 11, 2022 9:11 AM I80400 AUG 11, 2022 9:12 AM I80700 AUG 11, 2022 9:12 AM RELAY LABEL DEVICE LABEL 1 UNL 2 PNL 3 DSL 4 OVERFILL ALARM I80900 AUG 11, 2022 9:12 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 AUG 11, 2022 9:12 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 2 PNL 3 3 DSL 2 4 OVERFILL ALARM NONE I80A00 AUG 11, 2022 9:12 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 OVERFILL ALARM STANDARD I80C00 AUG 11, 2022 9:12 AM I80800 AUG 11, 2022 9:12 AM RELAY SETUP REPORT R 1:UNL TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 4:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 4:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 6:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 5:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 5:SENSOR OUT ALARM L10:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 5:SHORT ALARM L10:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 AUG 11, 2022 9:12 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 11, 2022 9:12 AM I72300 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 1-2 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA VAPOR PROCESSOR TYPE NONE IV4700 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ACCEPT HIGH ORVR: YES IV4A00 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 11, 2022 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 11, 2022 9:12 AM ISD VERSION: 01.07 Jaco 7773 Alarm History Responses Received: I10200 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508304 506890 2 INTERSTITIAL BD 202003 201403 3 4 PROBE / G.T. 161879 161431 4 INTERSTITIAL BD 201406 200991 5 UNUSED 9470693 9480171 6 UNUSED 9460594 9476923 7 UNUSED 9461650 9472467 8 UNUSED 9454301 9472687 9 STP SENSE BOARD 33193 33141 10 RELAY BOARD 15036 15073 11 UNUSED 9466281 9481764 12 UNUSED 9456335 9476716 13 UNUSED 9456049 9476847 14 UNUSED 9458492 9471843 15 UNUSED 9456225 9478296 16 UNUSED 9461198 9479393 COMM 1 ELEC DISP INT. 101303 101125 COMM 2 RS232 SERIAL BD 14926 14918 COMM 3 RS232 SERIAL BD 14970 14985 COMM 4 UNUSED 9460648 9481501 COMM 5 UNUSED 9455037 9475333 COMM 6 UNUSED 9460406 9471382 I90200 AUG 11, 2022 9:14 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED OVERFILL ALARM CLEAR 8-07-22 12:11AM T 1 TANK UNLEADED OVERFILL ALARM ALARM 8-07-22 12:07AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L13 PIPE TRANS SUNP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-03-22 9:48AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-03-22 9:48AM L 4 STP SUMP UNL STP SENSOR OUT ALARM ALARM 8-03-22 9:48AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-03-22 9:48AM L 6 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-03-22 9:48AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-03-22 9:48AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-03-22 9:48AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-03-22 9:48AM L13 PIPE TRANS SUNP SENSOR OUT ALARM ALARM 8-03-22 9:48AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-03-22 9:48AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-03-22 9:48AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-03-22 9:43AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-03-22 9:43AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-03-22 9:42AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-03-22 9:42AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 8-03-22 9:42AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 8-03-22 9:41AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 8-03-22 9:41AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 8-03-22 9:41AM L13 PIPE TRANS SUNP FUEL ALARM CLEAR 8-03-22 9:39AM L13 PIPE TRANS SUNP FUEL ALARM ALARM 8-03-22 9:39AM L 7 ANNULAR PNL ANN FUEL ALARM CLEAR 8-03-22 9:39AM L 7 ANNULAR PNL ANN FUEL ALARM ALARM 8-03-22 9:38AM L 2 ANNULAR DSL ANN FUEL ALARM CLEAR 8-03-22 9:38AM L 2 ANNULAR DSL ANN FUEL ALARM ALARM 8-03-22 9:38AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-03-22 9:38AM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-03-22 9:37AM L 4 STP SUMP UNL STP FUEL ALARM CLEAR 8-03-22 9:37AM L 4 STP SUMP UNL STP FUEL ALARM ALARM 8-03-22 9:37AM L 5 STP SUMP DSL STP FUEL ALARM CLEAR 8-03-22 9:36AM L 5 STP SUMP DSL STP FUEL ALARM ALARM 8-03-22 9:36AM L 6 STP SUMP PNL STP FUEL ALARM CLEAR 8-03-22 9:35AM L 6 STP SUMP PNL STP FUEL ALARM ALARM 8-03-22 9:35AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-01-22 11:05PM E 1 OTHER COMMUNICATION ALARM ALARM 8-01-22 10:56PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-14-22 7:27AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-12-22 2:55PM I11200 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 8-03-22 9:26AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 8-03-22 9:26AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 7-28-22 10:02AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 7-27-22 10:02AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-23-22 12:34PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-23-22 11:51AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-20-22 1:40PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-20-22 11:27AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-18-22 1:27PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-18-22 11:58AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-15-22 10:05AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-15-22 8:24AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-14-22 2:40AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-13-22 11:19PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-13-22 12:56AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-13-22 12:01AM I20600 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM AUG 7, 2022 12:07 AM DELIVERY NEEDED JUL 23, 2022 11:51 AM JUL 20, 2022 11:27 AM JUL 18, 2022 11:58 AM TANK 2 DIESEL TANK 3 PREMIUM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 11, 2022 9:14 AM I30200 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:37 AM FUEL ALARM JUL 12, 2022 2:55 PM SENSOR OUT ALARM 2 DSL ANN AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:38 AM FUEL ALARM JUL 12, 2022 11:28 AM SENSOR OUT ALARM 4 UNL STP AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:37 AM FUEL ALARM JUL 12, 2022 11:28 AM SENSOR OUT ALARM 5 DSL STP AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:36 AM FUEL ALARM JUL 12, 2022 11:28 AM SENSOR OUT ALARM 6 PNL STP AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:35 AM FUEL ALARM JUL 12, 2022 11:28 AM SENSOR OUT ALARM 7 PNL ANN AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:38 AM FUEL ALARM JUL 12, 2022 11:28 AM FUEL ALARM 9 DISP 1-2 AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:41 AM FUEL ALARM JUL 12, 2022 11:27 AM SENSOR OUT ALARM 10 DISP 3-4 AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:41 AM FUEL ALARM JUL 12, 2022 11:27 AM SENSOR OUT ALARM 11 DISP 5-6 AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:43 AM FUEL ALARM JUL 12, 2022 11:27 AM SENSOR OUT ALARM 12 DISP 7-8 AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:42 AM FUEL ALARM JUL 12, 2022 11:27 AM SENSOR OUT ALARM 13 TRANS SUNP AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:39 AM FUEL ALARM JUL 12, 2022 11:27 AM SENSOR OUT ALARM I31600 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 AUG 11, 2022 9:14 AM I40300 AUG 11, 2022 9:14 AM I34200 AUG 11, 2022 9:14 AM I34700 AUG 11, 2022 9:14 AM IV0100 AUG 11, 2022 9:14 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-08-02 10:02:29 A/L RATIO DEGRADATION FP 8 BLEND3 0.67 22-08-02 10:02:29 A/L RATIO DEGRADATION FP 7 BLEND3 0.71 22-08-01 10:02:33 A/L RATIO DEGRADATION FP 8 BLEND3 0.67 22-08-01 10:02:33 A/L RATIO DEGRADATION FP 7 BLEND3 0.70 22-07-31 10:02:26 A/L RATIO DEGRADATION FP 8 BLEND3 0.67 22-07-31 10:02:26 A/L RATIO DEGRADATION FP 7 BLEND3 0.68 22-07-30 10:02:37 A/L RATIO DEGRADATION FP 8 BLEND3 0.69 22-07-30 10:02:37 A/L RATIO DEGRADATION FP 7 BLEND3 0.67 22-07-29 10:02:53 A/L RATIO DEGRADATION FP 8 BLEND3 0.74 22-07-29 10:02:53 A/L RATIO DEGRADATION FP 7 BLEND3 0.66 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 21-04-14 10:02:04 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 19-03-20 10:01:25 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 18-07-09 10:02:32 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 18-07-09 10:02:32 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-08-04 10:03:23 READINESS ISD:PP EVR:PP ISD & EVR READY 22-08-03 10:02:33 READINESS ISD:PP EVR:NP EVR READINESS PENDING 22-08-03 09:52:11 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-08-03 09:52:11 ISD STARTUP 22-08-03 09:51:57 ISD SHUTDOWN 22-08-03 09:26:01 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 22-08-03 09:26:00 COLLECTION TEST HH07 GRADE TEST MANUALLY CLEARED 22-07-18 10:01:51 READINESS ISD:PP EVR:PP ISD & EVR READY 22-07-17 10:02:56 READINESS ISD:PP EVR:PN EVR READINESS PENDING 22-07-16 10:02:09 READINESS ISD:PP EVR:PN EVR READINESS PENDING Jaco 7773 Alarm History After Responses Received: I10200 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508304 507969 2 INTERSTITIAL BD 202003 201865 3 4 PROBE / G.T. 161879 161687 4 INTERSTITIAL BD 201406 201223 5 UNUSED 9470693 9521211 6 UNUSED 9460594 9520266 7 UNUSED 9461650 9512487 8 UNUSED 9454301 9518486 9 STP SENSE BOARD 33193 33222 10 RELAY BOARD 15036 15087 11 UNUSED 9466281 9524519 12 UNUSED 9456335 9521091 13 UNUSED 9456049 9521244 14 UNUSED 9458492 9513245 15 UNUSED 9456225 9512937 16 UNUSED 9461198 9521266 COMM 1 ELEC DISP INT. 101303 101243 COMM 2 RS232 SERIAL BD 14926 14955 COMM 3 RS232 SERIAL BD 14970 15021 COMM 4 UNUSED 9460648 9525618 COMM 5 UNUSED 9455037 9514432 COMM 6 UNUSED 9460406 9519508 I90200 AUG 11, 2022 11:09 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L13 PIPE TRANS SUNP SENSOR OUT ALARM CLEAR 8-11-22 9:42AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-11-22 9:41AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-11-22 9:41AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-11-22 9:41AM L13 PIPE TRANS SUNP SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 6 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 4 STP SUMP UNL STP SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-11-22 9:41AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-11-22 9:41AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-11-22 9:39AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-11-22 9:39AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-11-22 9:39AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-11-22 9:38AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 8-11-22 9:38AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 8-11-22 9:38AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 8-11-22 9:37AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 8-11-22 9:37AM L13 PIPE TRANS SUNP FUEL ALARM CLEAR 8-11-22 9:36AM L13 PIPE TRANS SUNP FUEL ALARM ALARM 8-11-22 9:35AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-11-22 9:34AM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-11-22 9:34AM L 2 ANNULAR DSL ANN FUEL ALARM CLEAR 8-11-22 9:34AM L 2 ANNULAR DSL ANN FUEL ALARM ALARM 8-11-22 9:34AM L 6 STP SUMP PNL STP FUEL ALARM CLEAR 8-11-22 9:32AM L 6 STP SUMP PNL STP FUEL ALARM ALARM 8-11-22 9:31AM L 5 STP SUMP DSL STP FUEL ALARM CLEAR 8-11-22 9:31AM L 5 STP SUMP DSL STP FUEL ALARM ALARM 8-11-22 9:31AM L 4 STP SUMP UNL STP FUEL ALARM CLEAR 8-11-22 9:30AM L 4 STP SUMP UNL STP FUEL ALARM ALARM 8-11-22 9:30AM T 1 TANK UNLEADED OVERFILL ALARM CLEAR 8-07-22 12:11AM T 1 TANK UNLEADED OVERFILL ALARM ALARM 8-07-22 12:07AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-03-22 9:49AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-03-22 9:49AM I11200 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 8-03-22 9:26AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 8-03-22 9:26AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 7-28-22 10:02AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 7-27-22 10:02AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-23-22 12:34PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-23-22 11:51AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-20-22 1:40PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-20-22 11:27AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-18-22 1:27PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-18-22 11:58AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-15-22 10:05AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-15-22 8:24AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-14-22 2:40AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-13-22 11:19PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-13-22 12:56AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-13-22 12:01AM I20600 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM AUG 7, 2022 12:07 AM DELIVERY NEEDED JUL 23, 2022 11:51 AM JUL 20, 2022 11:27 AM JUL 18, 2022 11:58 AM TANK 2 DIESEL TANK 3 PREMIUM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 11, 2022 11:09 AM I30200 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:34 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 2 DSL ANN AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:34 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 4 UNL STP AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:30 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 5 DSL STP AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:31 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 6 PNL STP AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:31 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 7 PNL ANN AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM AUG 3, 2022 9:38 AM FUEL ALARM 9 DISP 1-2 AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:37 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 10 DISP 3-4 AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:38 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 11 DISP 5-6 AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:39 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 12 DISP 7-8 AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:38 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM 13 TRANS SUNP AUG 11, 2022 9:41 AM SENSOR OUT ALARM AUG 11, 2022 9:35 AM FUEL ALARM AUG 3, 2022 9:48 AM SENSOR OUT ALARM I31600 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 AUG 11, 2022 11:09 AM I40300 AUG 11, 2022 11:09 AM I34200 AUG 11, 2022 11:09 AM I34700 AUG 11, 2022 11:09 AM IV0100 AUG 11, 2022 11:09 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-08-02 10:02:29 A/L RATIO DEGRADATION FP 8 BLEND3 0.67 22-08-02 10:02:29 A/L RATIO DEGRADATION FP 7 BLEND3 0.71 22-08-01 10:02:33 A/L RATIO DEGRADATION FP 8 BLEND3 0.67 22-08-01 10:02:33 A/L RATIO DEGRADATION FP 7 BLEND3 0.70 22-07-31 10:02:26 A/L RATIO DEGRADATION FP 8 BLEND3 0.67 22-07-31 10:02:26 A/L RATIO DEGRADATION FP 7 BLEND3 0.68 22-07-30 10:02:37 A/L RATIO DEGRADATION FP 8 BLEND3 0.69 22-07-30 10:02:37 A/L RATIO DEGRADATION FP 7 BLEND3 0.67 22-07-29 10:02:53 A/L RATIO DEGRADATION FP 8 BLEND3 0.74 22-07-29 10:02:53 A/L RATIO DEGRADATION FP 7 BLEND3 0.66 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 21-04-14 10:02:04 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 19-03-20 10:01:25 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 18-07-09 10:02:32 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 18-07-09 10:02:32 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-08-11 10:02:20 READINESS ISD:PP EVR:PP ISD & EVR READY 22-08-11 09:40:47 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-08-11 09:40:47 ISD STARTUP 22-08-11 09:40:27 ISD SHUTDOWN 22-08-04 10:03:23 READINESS ISD:PP EVR:PP ISD & EVR READY 22-08-03 10:02:33 READINESS ISD:PP EVR:NP EVR READINESS PENDING 22-08-03 09:52:11 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-08-03 09:52:11 ISD STARTUP 22-08-03 09:51:57 ISD SHUTDOWN 22-08-03 09:26:01 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED