Loading...
HomeMy WebLinkAboutFMC RESULTS 2022IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 9/16/2022 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR KRIS KARNS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 9/14/2022 Order Number: 3457900 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD, CA 93312 In an effort to keep all our record keeping and reporting requirements as current as possible, Tanknology kindly requests you notify Dawn Kohlmeyer in writing at dkohlmeyer@tanknology.com when your CUPA requires all records to be submitted electronically via the CERS database. Your assistance in this endeavor is greatly appreciated. Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3457900 Date:9/14/2022 Site Name / ID:7-ELEVEN #32241, MKT 2368 / 32241 Address:4101 CALLOWAY DRIVE City:BAKERSFIELD State:CA Zip:93312 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T4 RUL RUL 1 2 Existing Mechanical Red Jacket FX1V 412201141 31.00 189.0 3.00 29.00 175.00 10 4 Pass T5 PUL PUL 1 2 Existing Mechanical Vaporless LD-2000 070886 35.00 189.0 3.00 33.00 190.00 35 0 Fail T5 PUL PUL 1 2 Existing Mechanical Vaporless LD-2000 070886 35.00 189.0 3.00 33.00 170.00 20 7 Pass Technician Comments: The initial test on theT5 MLLD LD-2000 failed we have replaced the siphon jet valve and made an adjustment. All testing with passing results. Technician Name:Luis Navarro Certification #:147337 Technician Signature:Expire Date:11/29/2024 Environmental Compliance for Petroleum Systems © 2022 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3457900 Date:9/14/2022 Site Name/ID:7-ELEVEN #32241, MKT 2368 Address:4101 CALLOWAY DRIVE City:BAKERSFIELD State:CA Zip:93312 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested Technician Comments: Technician Name:Luis Navarro Signature: Environmental Compliance for Petroleum Systems ©2022 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, Tx 78759 Luis Navarro 10024393 09/14/2022 7-ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD 93312 Class A General Engineering 743160 8171123 12/31/2022 05/26/2024 07/08/2024 07/14/2024 09/14/2022 6 Veeder Root:ATG Technician (A28342) OPW:EVR Phase 1 (101183) VMI:TLDT-5000 Tester (4480) Veeder Root TLS-350R 336.02 L1 DISP 1-2 PAN L2 L3 DISP 5-6 PAN L4 L5 L6 L7 87 STP SUMP L8 L9 91 FILL SUMP L10 L11 S9 87 VRL UDC VAC S10 87 PRODUCT LINE VAC S11 87 STP SUMP-FILL CNCT S12 91 FILL-VENT-CONT SUMP S13 91 PRODUCT LINE VAC S14 91 STP SUMPFILL CNCT 794380-208 DISP 3-4 PAN DISP PAN 7-8 87 ANNULAR 87 FILL SUMP 91-ANNULAR 91 STP SUMP VAPOR PIPING PAN 794380-208 794380-208 794380-208 794380-303 794380-208 794380-208 794380-303 794380-208 794380-208 794380-208 857280-100 857280-100 857280-100 857280-100 857280-100 857280-100 T4 RUL T4 RUL T5 PUL Red Jacket FX1DV T5 PULVaporless LD-2000 T4 RUL T4 RUL T5 PUL T5 PUL 847390-107 847390-107 09/14/2022 10024393 09/14/2022 7-ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD 93312 Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, TX 78759 Luis Navarro 743160 8171123 12/31/2022 07/08/2024 PEI Rp1200 / Hydrostatic OPW Spill Buckets 09/14/2022 2 OPW:EVR Phase 1 T4 RUL T5 PUL OPW OPW SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 7-ELEVEN #32241, MKT 2368 Date of Testing: 9/14/2022 Facility Address: 4101 CALLOWAY DRIVE , BAKERSFIELD, CA 93312 Facility Contact: Iman 5/18/16 Phone: 661-5492711 Date Local Agency Was Notified of Testing: 8/4/2022 Name of Local Agency Inspector (if present during testing): Peter Bakersfield Fire 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Luis Navarro Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 / 8171123 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T4 RUL RUL - Fill 1 - Direct - Below Grade in containment sump Direct Bury Contained in Sump 11.00 13.00 15 min 12:30:00 11.00 in. H20 13:30:00 11.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T5 PUL PUL - Fill 1 - Direct - Below Grade in containment sump Direct Bury Contained in Sump 11.00 13.00 15 min 12:30:00 11.00 in. H20 13:30:00 11.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Direct Bury Contained in Sump min +/- Spill Box # Direct Bury Contained in Sump min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:9/14/2022 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3457900 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3457900 Site ID / Name:32241 / 7-ELEVEN #32241, MKT 2368 Address:4101 CALLOWAY DRIVE City:BAKERSFIELD State:CA Zip:93312 W.O.# SC1-3457900 Responses Received: I10200 SEP 14, 2022 2:00 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164003 163584 2 4 PROBE / G.T. 163133 162876 3 INTERSTITIAL BD 201783 201474 4 INTERSTITIAL BD 201856 201548 5 8SMARTSENSOR BD 39305 39296 6 7SMARTSENSOR BD 506416 505957 7 UNUSED 4860213 4815267 8 UNUSED 4857228 4813120 9 RELAY BOARD 14961 14945 10 RELAY BOARD 15120 15106 11 STP SENSE BOARD 33187 33150 12 UNUSED 4860669 4819328 13 UNUSED 4860172 4813388 14 UNUSED 4860330 4811903 15 UNUSED 4852211 4814804 16 UNUSED 4851352 4816678 COMM 1 ELEC DISP INT. 101104 101093 COMM 2 ELEC DISP INT. 101245 101141 COMM 3 SERIAL SAT BD 487215 486628 COMM 4 UNUSED 4854247 4816152 COMM 5 RS485 SERIAL BD 68818 68847 COMM 6 MT COMM BOARD 409628 409176 I90200 SEP 14, 2022 2:00 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE+ACM- 346336-100-C CREATED - 21.02.13.11.53 S-MODULE+ACM- 330160-104-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APM I11100 SEP 14, 2022 2:00 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 PIPE 87 FILL SUMP SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 8 ANNULAR 91-ANNULAR SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 2 DISP PAN DISP 3-4 PAN SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 5 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 3 DISP PAN DISP 5-6 PAN SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 7 STP SUMP 87 STP SUMP SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L11 PIPE VAPOR PIPING PAN SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 4 DISP PAN DISP PAN 7-8 SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L10 STP SUMP 91 STP SUMP SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L 9 PIPE 91 FILL SUMP SENSOR OUT ALARM CLEAR 9-14-22 1:01PM L11 PIPE VAPOR PIPING PAN SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 5 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 9-14-22 1:00PM L10 STP SUMP 91 STP SUMP SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 9 PIPE 91 FILL SUMP SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 8 ANNULAR 91-ANNULAR SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 4 DISP PAN DISP PAN 7-8 SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 7 STP SUMP 87 STP SUMP SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 3 DISP PAN DISP 5-6 PAN SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 2 DISP PAN DISP 3-4 PAN SENSOR OUT ALARM ALARM 9-14-22 1:00PM L 6 PIPE 87 FILL SUMP SENSOR OUT ALARM ALARM 9-14-22 1:00PM s14 OTHER 91 STPSUMP-FILLCNCT HIGH LIQUID ALARM CLEAR 9-14-22 12:59PM s13 OTHER 91 PRODUCT LINE VAC HIGH LIQUID ALARM CLEAR 9-14-22 12:59PM s12 OTHER 91FILL-VENT-CONTSUMP HIGH LIQUID ALARM CLEAR 9-14-22 12:59PM s14 OTHER 91 STPSUMP-FILLCNCT HIGH LIQUID ALARM ALARM 9-14-22 12:59PM s13 OTHER 91 PRODUCT LINE VAC HIGH LIQUID ALARM ALARM 9-14-22 12:59PM s12 OTHER 91FILL-VENT-CONTSUMP HIGH LIQUID ALARM ALARM 9-14-22 12:59PM s12 OTHER 91FILL-VENT-CONTSUMP NO VACUUM ALARM CLEAR 9-14-22 12:59PM s12 OTHER 91FILL-VENT-CONTSUMP NO VACUUM ALARM ALARM 9-14-22 12:58PM s13 OTHER 91 PRODUCT LINE VAC NO VACUUM ALARM CLEAR 9-14-22 12:58PM s14 OTHER 91 STPSUMP-FILLCNCT NO VACUUM ALARM CLEAR 9-14-22 12:58PM s13 OTHER 91 PRODUCT LINE VAC NO VACUUM ALARM ALARM 9-14-22 12:58PM s14 OTHER 91 STPSUMP-FILLCNCT NO VACUUM ALARM ALARM 9-14-22 12:58PM s10 OTHER 87 PRODUCT LINE VAC HIGH LIQUID ALARM CLEAR 9-14-22 12:57PM s 9 OTHER 87 FILL VRL UDC VAC HIGH LIQUID ALARM CLEAR 9-14-22 12:57PM s11 OTHER 87 STPSUMP-FILLCNCT HIGH LIQUID ALARM CLEAR 9-14-22 12:57PM s10 OTHER 87 PRODUCT LINE VAC HIGH LIQUID ALARM ALARM 9-14-22 12:57PM s 9 OTHER 87 FILL VRL UDC VAC HIGH LIQUID ALARM ALARM 9-14-22 12:57PM s11 OTHER 87 STPSUMP-FILLCNCT HIGH LIQUID ALARM ALARM 9-14-22 12:57PM s11 OTHER 87 STPSUMP-FILLCNCT NO VACUUM ALARM CLEAR 9-14-22 12:57PM s11 OTHER 87 STPSUMP-FILLCNCT NO VACUUM ALARM ALARM 9-14-22 12:57PM s10 OTHER 87 PRODUCT LINE VAC NO VACUUM ALARM CLEAR 9-14-22 12:56PM s10 OTHER 87 PRODUCT LINE VAC NO VACUUM ALARM ALARM 9-14-22 12:56PM s 9 OTHER 87 FILL VRL UDC VAC NO VACUUM ALARM CLEAR 9-14-22 12:55PM s 9 OTHER 87 FILL VRL UDC VAC NO VACUUM ALARM ALARM 9-14-22 12:55PM L11 PIPE VAPOR PIPING PAN FUEL ALARM CLEAR 9-14-22 12:54PM L11 PIPE VAPOR PIPING PAN FUEL ALARM ALARM 9-14-22 12:51PM L 1 DISP PAN DISP 1-2 PAN FUEL ALARM CLEAR 9-14-22 12:50PM L 1 DISP PAN DISP 1-2 PAN FUEL ALARM ALARM 9-14-22 12:49PM L 2 DISP PAN DISP 3-4 PAN FUEL ALARM CLEAR 9-14-22 12:49PM L 2 DISP PAN DISP 3-4 PAN FUEL ALARM ALARM 9-14-22 12:49PM I11200 SEP 14, 2022 2:00 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 5 TANK PUL HIGH WATER WARNING CLEAR 9-14-22 12:40PM T 4 TANK RUL HIGH WATER WARNING CLEAR 9-14-22 12:39PM T 5 TANK PUL HIGH PRODUCT ALARM CLEAR 9-14-22 12:37PM T 5 TANK PUL HIGH PRODUCT ALARM ALARM 9-14-22 12:36PM T 5 TANK PUL DELIVERY NEEDED CLEAR 9-14-22 12:36PM T 4 TANK RUL LOW TEMP WARNING CLEAR 9-14-22 12:35PM T 4 TANK RUL LOW TEMP WARNING ALARM 9-14-22 12:35PM T 4 TANK RUL HIGH PRODUCT ALARM CLEAR 9-14-22 12:35PM T 4 TANK RUL HIGH PRODUCT ALARM ALARM 9-14-22 12:34PM T 4 TANK RUL DELIVERY NEEDED CLEAR 9-14-22 12:33PM T 5 TANK PUL HIGH WATER WARNING ALARM 9-14-22 12:31PM T 4 TANK RUL HIGH WATER WARNING ALARM 9-14-22 12:31PM T 5 TANK PUL DELIVERY NEEDED ALARM 9-14-22 12:27PM T 4 TANK RUL DELIVERY NEEDED ALARM 9-14-22 12:26PM OTHER ISD VAPOR LEAK WARN ALARM 9-14-22 6:05AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-12-22 9:33AM h 3 OTHER FP3: BLEND3 GROSS COLLECT WARN CLEAR 9-11-22 6:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-10-22 6:02AM h 3 OTHER FP3: BLEND3 GROSS COLLECT WARN ALARM 9-10-22 6:02AM OTHER ISD VAPOR LEAK WARN CLEAR 9-08-22 9:34AM OTHER ISD VAPOR LEAK WARN ALARM 9-07-22 6:05AM OTHER ISD VAPOR LEAK WARN CLEAR 9-01-22 10:01AM OTHER ISD VAPOR LEAK WARN ALARM 8-30-22 6:05AM OTHER ISD VAPOR LEAK WARN CLEAR 8-24-22 9:26AM OTHER ISD VAPOR LEAK WARN ALARM 8-23-22 6:05AM OTHER ISD VAPOR LEAK WARN CLEAR 8-17-22 12:21PM OTHER ISD VAPOR LEAK WARN ALARM 8-17-22 6:05AM SYSTEM PRINTER ERROR CLEAR 8-13-22 3:16PM SYSTEM PAPER OUT CLEAR 8-13-22 3:16PM SYSTEM PRINTER ERROR ALARM 8-13-22 3:15PM SYSTEM PAPER OUT ALARM 8-13-22 3:15PM OTHER ISD VAPOR LEAK WARN CLEAR 8-11-22 8:38AM OTHER ISD VAPOR LEAK WARN ALARM 8-11-22 6:05AM SYSTEM PRINTER ERROR CLEAR 6-01-22 10:59PM SYSTEM PAPER OUT CLEAR 6-01-22 10:59PM SYSTEM PRINTER ERROR ALARM 6-01-22 10:58PM SYSTEM PAPER OUT ALARM 6-01-22 10:58PM SYSTEM PRINTER ERROR CLEAR 6-01-22 10:57PM SYSTEM PRINTER ERROR ALARM 6-01-22 10:57PM SYSTEM PRINTER ERROR CLEAR 6-01-22 10:57PM SYSTEM PAPER OUT CLEAR 6-01-22 10:57PM SYSTEM PRINTER ERROR ALARM 6-01-22 10:55PM SYSTEM PAPER OUT ALARM 6-01-22 10:55PM I20600 SEP 14, 2022 2:00 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 TANK ALARM HISTORY TANK 4 RUL HIGH WATER ALARM SEP 14, 2022 12:31 PM OVERFILL ALARM SEP 14, 2022 12:34 PM MAY 12, 2022 12:35 AM APR 27, 2022 11:56 AM LOW PRODUCT ALARM SEP 14, 2022 12:26 PM HIGH PRODUCT ALARM SEP 14, 2022 12:34 PM PROBE OUT SEP 14, 2022 12:35 PM SEP 14, 2022 12:27 PM HIGH WATER WARNING SEP 14, 2022 12:31 PM DELIVERY NEEDED SEP 14, 2022 12:26 PM MAX PRODUCT ALARM SEP 14, 2022 12:34 PM LOW TEMP WARNING SEP 14, 2022 12:35 PM TANK 5 PUL HIGH WATER ALARM SEP 14, 2022 12:31 PM OVERFILL ALARM SEP 14, 2022 12:36 PM MAY 9, 2022 12:33 AM LOW PRODUCT ALARM SEP 14, 2022 12:28 PM HIGH PRODUCT ALARM SEP 14, 2022 12:36 PM PROBE OUT SEP 14, 2022 12:36 PM SEP 14, 2022 12:27 PM HIGH WATER WARNING SEP 14, 2022 12:31 PM DELIVERY NEEDED SEP 14, 2022 12:27 PM MAX PRODUCT ALARM SEP 14, 2022 12:36 PM TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 SEP 14, 2022 2:00 PM I30200 SEP 14, 2022 2:00 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 PAN SEP 14, 2022 12:49 PM FUEL ALARM MAY 13, 2022 9:30 AM FUEL ALARM 2 DISP 3-4 PAN SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:49 PM FUEL ALARM MAY 13, 2022 9:31 AM FUEL ALARM 3 DISP 5-6 PAN SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:48 PM FUEL ALARM MAY 13, 2022 9:38 AM SENSOR OUT ALARM 4 DISP PAN 7-8 SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:47 PM FUEL ALARM MAY 13, 2022 9:38 AM SENSOR OUT ALARM 5 87 ANNULAR SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:43 PM LOW LIQUID ALARM SEP 14, 2022 12:43 PM LOW LIQUID ALARM 6 87 FILL SUMP SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:42 PM FUEL ALARM MAY 13, 2022 9:38 AM SENSOR OUT ALARM 7 87 STP SUMP SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:41 PM FUEL ALARM MAY 13, 2022 9:38 AM SENSOR OUT ALARM 8 91-ANNULAR SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:46 PM LOW LIQUID ALARM SEP 14, 2022 12:46 PM HIGH LIQUID ALARM 9 91 FILL SUMP SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:45 PM FUEL ALARM MAY 13, 2022 9:23 AM FUEL ALARM 10 91 STP SUMP SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:44 PM FUEL ALARM MAY 13, 2022 9:19 AM FUEL ALARM 11 VAPOR PIPING PAN SEP 14, 2022 1:00 PM SENSOR OUT ALARM SEP 14, 2022 12:51 PM FUEL ALARM MAY 13, 2022 9:45 AM FUEL ALARM I31600 SEP 14, 2022 2:00 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 1-2 FLOW METER 2 3-4 FLOW METER 3 5-6 FLOW METER 4 7-8 FLOW METER 8 PRESSURE SENSOR 9 87 FILL VRL UDC VAC SEP 14, 2022 12:57 PM HIGH LIQUID ALARM SEP 14, 2022 12:55 PM NO VACUUM ALARM MAY 13, 2022 9:33 AM HIGH LIQUID ALARM 10 87 PRODUCT LINE VAC SEP 14, 2022 12:57 PM HIGH LIQUID ALARM SEP 14, 2022 12:56 PM NO VACUUM ALARM MAY 13, 2022 9:33 AM HIGH LIQUID ALARM 11 87 STPSUMP-FILLCNCT SEP 14, 2022 12:57 PM HIGH LIQUID ALARM SEP 14, 2022 12:57 PM NO VACUUM ALARM MAY 13, 2022 9:33 AM HIGH LIQUID ALARM 12 91FILL-VENT-CONTSUMP SEP 14, 2022 12:59 PM HIGH LIQUID ALARM SEP 14, 2022 12:58 PM NO VACUUM ALARM MAY 13, 2022 9:34 AM HIGH LIQUID ALARM 13 91 PRODUCT LINE VAC SEP 14, 2022 12:59 PM HIGH LIQUID ALARM SEP 14, 2022 12:58 PM NO VACUUM ALARM MAY 13, 2022 9:34 AM HIGH LIQUID ALARM 14 91 STPSUMP-FILLCNCT SEP 14, 2022 12:59 PM HIGH LIQUID ALARM SEP 14, 2022 12:58 PM NO VACUUM ALARM 16 ATM P SENSOR 5-6 I40200 SEP 14, 2022 2:01 PM I40300 SEP 14, 2022 2:01 PM I34200 SEP 14, 2022 2:01 PM I34700 SEP 14, 2022 2:01 PM IV0100 SEP 14, 2022 2:01 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100+ACU- EVR/ISD PASS TIME : 0+ACU- WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-09-14 06:05:19 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 9.32 22-09-12 06:07:02 A/L RATIO DEGRADATION FP 3 BLEND3 1.61 22-09-11 06:04:14 A/L RATIO DEGRADATION FP 3 BLEND3 1.60 22-09-10 06:02:13 A/L RATIO DEGRADATION FP 3 BLEND3 1.55 22-09-10 06:02:13 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 1.91 22-09-08 06:05:39 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 9.41 22-09-07 06:05:15 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 9.53 22-09-01 06:05:57 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 9.58 22-08-31 06:06:10 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 9.62 22-08-30 06:05:51 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 9.40 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-11-27 09:04:49 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 2.11 18-12-12 09:02:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.77 18-09-25 09:02:34 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 18-09-14 09:04:48 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 16-12-17 09:01:15 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 16-12-17 09:01:15 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 16-12-11 09:01:17 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 16-11-20 09:01:50 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 16-09-14 09:03:25 A/L RATIO DEGRADATION FP 5 BLEND3 0.78 15-03-16 09:01:11 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD SHUTDOWN +ACY- MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-09-14 13:01:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-09-14 13:01:57 ISD STARTUP 22-09-14 13:01:46 ISD SHUTDOWN 22-09-12 09:33:44 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 22-09-11 06:04:14 READINESS ISD:PP EVR:PP ISD +ACY- EVR READY 22-09-10 11:18:23 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-09-10 11:18:23 ISD STARTUP 22-09-10 11:18:20 ISD SHUTDOWN 22-09-08 09:34:00 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 22-09-01 10:01:54 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED W.O.# SC1-3457900 Responses Received: 200185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 SEP 14, 2022 2:01 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 4 RUL 5557 36.53 0.0 85.7 8844 5 PUL 5683 50.40 0.0 88.4 4012 I90500SEP 14, 2022 2:01 PMSOFTWARE REVISION LEVEL VERSION 336.02SOFTWARE+ACM- 346336-100-C CREATED - 21.02.13.11.53 S-MODULE+ACM- 330160-104-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APM I50500SEP 14, 2022 2:01 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMON DD YYYY HH:MM:SS xM I50201 SEP 14, 2022 2:01 PM SHIFT TIME 1 : 7:00 AM I50202SEP 14, 2022 2:01 PM SHIFT TIME 2 : DISABLED I50203SEP 14, 2022 2:01 PM SHIFT TIME 3 : DISABLED I50204SEP 14, 2022 2:02 PM SHIFT TIME 4 : DISABLED I54600SEP 14, 2022 2:02 PM TANK PER TST NEEDED WRN: DISABLED I54900SEP 14, 2022 2:02 PM TANK ANN TST NEEDED WRN: DISABLED I55300SEP 14, 2022 2:02 PM LINE RE-ENABLE METHODPASS LINE TEST I55600SEP 14, 2022 2:02 PM LINE PER TST NEEDED WRN: DISABLED I55900SEP 14, 2022 2:02 PM LINE ANN TST NEEDED WRN: DISABLED I50D00SEP 14, 2022 2:02 PM PRINT TC VOLUMESENABLED I50E00SEP 14, 2022 2:02 PM TEMP COMPENSATIONVALUE (DEG F ): 60.0 I60B00SEP 14, 2022 2:02 PM STICK HEIGHT OFFSET ENABLE STATUSDISABLED I51400SEP 14, 2022 2:02 PM H-PROTOCOL DATA FORMATHEIGHT I51A01SEP 14, 2022 2:02 PM DAYLIGHT SAVING TIMEENABLED ON I51B00SEP 14, 2022 2:02 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 SEP 14, 2022 2:02 PM RE-DIRECT LOCAL PRINTOUTDISABLED I50400 SEP 14, 2022 2:02 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900SEP 14, 2022 2:02 PM TANK CHART SECURITYDISABLED I5BD00SEP 14, 2022 2:02 PM CUSTOM ALARM LABELS DISABLED I56000SEP 14, 2022 2:02 PM MASS/DENSITY DISABLED I88101 SEP 14, 2022 2:02 PMPORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITYCODE : DISABLED I88102SEP 14, 2022 2:02 PMPORT SETTINGS: COMM BOARD : 2 (EDIM )RS-232 SECURITYCODE : DISABLED I88103SEP 14, 2022 2:02 PMPORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : DISABLED DTR NORMAL STATE: HIGH I88104SEP 14, 2022 2:02 PM I88105SEP 14, 2022 2:02 PMPORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : DISABLED I88106SEP 14, 2022 2:02 PMPORT SETTINGS: COMM BOARD : 6 (MTCOMM) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : DISABLED I52000SEP 14, 2022 2:02 PM RECEIVER AUTO DIAL TYPE +ACY- START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE DEC 4, 2012 DISABLED 2 ON DATE DEC 4, 2012 DISABLED 3 ON DATE DEC 4, 2012 DISABLED 4 ON DATE DEC 4, 2012 DISABLED 5 ON DATE DEC 4, 2012 DISABLED 6 ON DATE DEC 4, 2012 DISABLED 7 ON DATE DEC 4, 2012 DISABLED 8 WEEKLY THR 4:43 PM I60100SEP 14, 2022 2:02 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 OFF 2 OFF 3 OFF 4 RUL ON 5 PUL ON 6 OFF 7 OFF 8 OFF I60200SEP 14, 2022 2:02 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 2 3 4 RUL 5 PUL 6 7 8 I60300SEP 14, 2022 2:02 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 1 2 2 3 3 4 RUL 4 5 PUL 5 6 6 7 7 8 8 I60900SEP 14, 2022 2:02 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 0.000000 2 0.000000 3 0.000000 4 RUL 0.000700 5 PUL 0.000700 6 0.000000 7 0.000000 8 0.000000 I60700SEP 14, 2022 2:02 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 0.00 2 0.00 3 0.00 4 RUL 91.63 5 PUL 91.63 6 0.00 7 0.00 8 0.00 I60A00SEP 14, 2022 2:02 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 1 PT 0 2 1 PT 0 3 1 PT 0 4 RUL 20 PTS 14544 5 PUL 4 PTS 9695 6 1 PT 0 7 1 PT 0 8 1 PT 0 I60400SEP 14, 2022 2:02 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 14544 5 PUL 9695 6 0 7 0 8 0 I60500SEP 14, 2022 2:02 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 0 0 0 0 2 0 0 0 0 3 0 0 0 0 4 RUL 14544 11764 7298 2825 5 PUL 9695 7859 4863 1863 6 0 0 0 0 7 0 0 0 0 8 0 0 0 0 I60600SEP 14, 2022 2:02 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 RUL 14544 14282 13816 13221 12530 11764 10937 10066 9162 8235 7298 6360 5433 4527 3654 2825 2054 1359 758 284 5 PUL 9695 0 0 0 0 7859 0 0 0 0 4863 0 0 0 0 1863 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500SEP 14, 2022 2:02 PM TANK PRODUCT LABEL METER DATA 1 NO 2 NO 3 NO 4 RUL YES 5 PUL YES 6 NO 7 NO 8 NO I62F00 SEP 14, 2022 2:02 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 4 RUL 4.0 IN. 5 PUL 4.0 IN. I62700SEP 14, 2022 2:02 PM 4 RUL 1.0 5 PUL 1.0 I64200SEP 14, 2022 2:02 PM 4 RUL LOW 5 PUL LOW I62400SEP 14, 2022 2:02 PM 4 RUL 1.5 5 PUL 1.5 I62800 SEP 14, 2022 2:02 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 14544 5 PUL 9695 6 0 7 0 8 0 I62300SEP 14, 2022 2:02 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 13090 5 PUL 8726 6 0 7 0 8 0 I62200SEP 14, 2022 2:02 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 13817 5 PUL 9210 6 0 7 0 8 0 I62900SEP 14, 2022 2:02 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 2182 5 PUL 1454 6 0 7 0 8 0 I62100SEP 14, 2022 2:02 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 800 5 PUL 800 6 0 7 0 8 0 I62600SEP 14, 2022 2:02 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 99 2 99 3 99 4 RUL 15 5 PUL 15 6 99 7 99 8 99 I62500SEP 14, 2022 2:02 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 99 2 99 3 99 4 RUL 40 5 PUL 40 6 99 7 99 8 99 I60800SEP 14, 2022 2:02 PM TANK TILT TANK PRODUCT LABEL INCHES 1 0.00 2 0.00 3 0.00 4 RUL 0.00 5 PUL -0.50 6 0.00 7 0.00 8 0.00 I60B00SEP 14, 2022 2:02 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00SEP 14, 2022 2:02 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 0.00 2 0.00 3 0.00 4 RUL 0.00 5 PUL 0.00 6 0.00 7 0.00 8 0.00 I61200SEP 14, 2022 2:02 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 NONE NONE 2 NONE NONE 3 NONE NONE 4 RUL NONE NONE 5 PUL NONE NONE 6 NONE NONE 7 NONE NONE 8 NONE NONE I63600SEP 14, 2022 2:02 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 3636 5 PUL 2423 6 0 7 0 8 0 I62A00SEP 14, 2022 2:02 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 7417 5 PUL 4944 6 0 7 0 8 0 I62C00SEP 14, 2022 2:02 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 STANDARD 2 STANDARD 3 STANDARD 4 RUL STANDARD 5 PUL STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I62D00SEP 14, 2022 2:02 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 RUL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 5 PUL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 6 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 7 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 8 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100SEP 14, 2022 2:02 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 OFF OFF 2 OFF OFF 3 OFF OFF 4 RUL OFF OFF 5 PUL OFF OFF 6 OFF OFF 7 OFF OFF 8 OFF OFF I63000SEP 14, 2022 2:02 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 OFF 2 OFF 3 OFF 4 RUL OFF 5 PUL OFF 6 OFF 7 OFF 8 OFF I63200 SEP 14, 2022 2:02 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 OFF 2 OFF 3 OFF 4 RUL OFF 5 PUL OFF 6 OFF 7 OFF 8 OFF I61000SEP 14, 2022 2:02 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 1 2 1 3 1 4 RUL 3 5 PUL 3 6 1 7 1 8 1 I63A00SEP 14, 2022 2:02 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 10.00+ACU- 2 10.00+ACU- 3 10.00+ACU- 4 RUL 10.00+ACU- 5 PUL 10.00+ACU- 6 10.00+ACU- 7 10.00+ACU- 8 10.00+ACU- I61100SEP 14, 2022 2:02 PM LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKJUL 1, 2009START TIME : DISABLEDTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED I61300SEP 14, 2022 2:02 PMCSLD PROBABLITY OF DETECTION I61400SEP 14, 2022 2:02 PMCSLD CLIMATE FACTOR I61600SEP 14, 2022 2:02 PM TANK PRODUCT LABEL CAL UPDATE 1 IMMEDIATE 2 IMMEDIATE 3 IMMEDIATE 4 RUL IMMEDIATE 5 PUL IMMEDIATE 6 IMMEDIATE 7 IMMEDIATE 8 IMMEDIATE I61A00SEP 14, 2022 2:02 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 DISABLED 2 DISABLED 3 DISABLED 4 RUL DISABLED 5 PUL DISABLED 6 DISABLED 7 DISABLED 8 DISABLED I61B00SEP 14, 2022 2:02 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00SEP 14, 2022 2:02 PM CSLD REPORT ONLY I62B00SEP 14, 2022 2:02 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 ??? 0, 0 2 ??? 0, 0 3 ??? 0, 0 4 RUL ??? 0, 0 5 PUL ??? 0, 0 6 ??? 0, 0 7 ??? 0, 0 8 ??? 0, 0 I63300 SEP 14, 2022 2:02 PM LEAK TEST REPORT FORMAT: NORMAL I63400SEP 14, 2022 2:02 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 0 5 PUL 0 6 0 7 0 8 0 I63500SEP 14, 2022 2:02 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 1 2 1 3 1 4 RUL 1 5 PUL 1 6 1 7 1 8 1 I63900SEP 14, 2022 2:02 PM SEP 14, 2022 2:02 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 END FACTOR: NONE 2 END FACTOR: NONE 3 END FACTOR: NONE 4 RUL END FACTOR: HEMISPHER 5 PUL END FACTOR: HEMISPHER 6 END FACTOR: NONE 7 END FACTOR: NONE 8 END FACTOR: NONE I78000SEP 14, 2022 2:03 PM I77700SEP 14, 2022 2:03 PM I77800SEP 14, 2022 2:03 PM I78C00SEP 14, 2022 2:03 PM I78300SEP 14, 2022 2:03 PM I78F00SEP 14, 2022 2:03 PM I78700SEP 14, 2022 2:03 PM I70200SEP 14, 2022 2:03 PM LIQUID LABEL DEVICE LABEL 1 DISP 1-2 PAN 2 DISP 3-4 PAN 3 DISP 5-6 PAN 4 DISP PAN 7-8 5 87 ANNULAR 6 87 FILL SUMP 7 87 STP SUMP 8 91-ANNULAR 9 91 FILL SUMP 10 91 STP SUMP 11 VAPOR PIPING PAN 12 13 14 15 16 I70300SEP 14, 2022 2:03 PM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1-2 PAN TRI-STATE (SINGLE FLOAT) 2 DISP 3-4 PAN TRI-STATE (SINGLE FLOAT) 3 DISP 5-6 PAN TRI-STATE (SINGLE FLOAT) 4 DISP PAN 7-8 TRI-STATE (SINGLE FLOAT) 5 87 ANNULAR DUAL POINT HYDROSTATIC 6 87 FILL SUMP TRI-STATE (SINGLE FLOAT) 7 87 STP SUMP TRI-STATE (SINGLE FLOAT) 8 91-ANNULAR DUAL POINT HYDROSTATIC 9 91 FILL SUMP TRI-STATE (SINGLE FLOAT) 10 91 STP SUMP TRI-STATE (SINGLE FLOAT) 11 VAPOR PIPING PAN TRI-STATE (SINGLE FLOAT) 12 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400SEP 14, 2022 2:03 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1-2 PAN DISPENSER PAN 2 DISP 3-4 PAN DISPENSER PAN 3 DISP 5-6 PAN DISPENSER PAN 4 DISP PAN 7-8 DISPENSER PAN 5 87 ANNULAR ANNULAR SPACE 6 87 FILL SUMP PIPING SUMP 7 87 STP SUMP STP SUMP 8 91-ANNULAR ANNULAR SPACE 9 91 FILL SUMP PIPING SUMP 10 91 STP SUMP STP SUMP 11 VAPOR PIPING PAN PIPING SUMP 12 OTHER SENSORS 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200SEP 14, 2022 2:03 PM I74300SEP 14, 2022 2:03 PM I74400 SEP 14, 2022 2:03 PM I74700SEP 14, 2022 2:03 PM I74800SEP 14, 2022 2:03 PM I74900SEP 14, 2022 2:03 PM I7BC00 SEP 14, 2022 2:03 PM I80200SEP 14, 2022 2:03 PM I80300SEP 14, 2022 2:03 PM I80400SEP 14, 2022 2:03 PM I80700SEP 14, 2022 2:03 PM RELAY LABEL DEVICE LABEL 1 2 3 4 5 87 STP 6 PREMIUM STP 7 8 I80900SEP 14, 2022 2:03 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 NORMALLY OPEN 2 NORMALLY OPEN 3 NORMALLY OPEN 4 NORMALLY OPEN 5 87 STP NORMALLY OPEN 6 PREMIUM STP NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00SEP 14, 2022 2:03 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 NONE 2 NONE 3 NONE 4 NONE 5 87 STP 4 6 PREMIUM STP 5 7 NONE 8 NONE I80A00SEP 14, 2022 2:03 PM RELAY TYPE RELAY DESIGNATION TYPE 1 STANDARD 2 STANDARD 3 STANDARD 4 STANDARD 5 87 STP PUMP CONTROL OUTPUT 6 PREMIUM STP PUMP CONTROL OUTPUT 7 STANDARD 8 STANDARD I80C00SEP 14, 2022 2:03 PM I80800SEP 14, 2022 2:03 PM RELAY SETUP REPORT R 1: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 2: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 5:87 STP TYPE: PUMP CONTROL OUTPUTTANK +ACM-: 4 IN-TANK ALARMS T 4:LOW PRODUCT ALARM T 4:GROSS TEST FAIL LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L 7:HIGH LIQUID ALARM L 5:LOW LIQUID ALARM COMM SIDE DIM ALM ALL:DISABLED DIM ALARM ALL:COMMUNICATION ALARM ALL:TRANSACTION ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER ALARM ALL:LOW LIQUID ALARM ALL:RELAY ACTIVE ALL:INSTALL ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL MISSING RELAY SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 6:PREMIUM STP TYPE: PUMP CONTROL OUTPUTTANK +ACM-: 5 IN-TANK ALARMS T 5:LOW PRODUCT ALARM T 5:GROSS TEST FAIL LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L 8:HIGH LIQUID ALARM L 8:LOW LIQUID ALARM COMM SIDE DIM ALM ALL:DISABLED DIM ALARM ALL:COMMUNICATION ALARM ALL:TRANSACTION ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:FUEL ALARM ALL:LOW LIQUID ALARM ALL:INSTALL ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 7: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - I79000SEP 14, 2022 2:03 PM EDIM:1 VR:349781-001-D TD:01.08.15.07.12 EDIM:2 VR:349867-001-C TD:16.05.27.07.44 I79100SEP 14, 2022 2:03 PM I72300 SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 1-2 FLOW METER AIR FLOW METER 02 3-4 FLOW METER AIR FLOW METER03 5-6 FLOW METER AIR FLOW METER04 7-8 FLOW METER AIR FLOW METER05 UNKNOWN 06 UNKNOWN07 UNKNOWN08 PRESSURE SENSOR VAPOR PRESSURE09 87 FILL VRL UDC VAC VAC SENSOR 10 87 PRODUCT LINE VAC VAC SENSOR11 87 STPSUMP-FILLCNCT VAC SENSOR12 91FILL-VENT-CONTSUMP VAC SENSOR13 91 PRODUCT LINE VAC VAC SENSOR 14 91 STPSUMP-FILLCNCT VAC SENSOR15 UNKNOWN16 ATM P SENSOR 5-6 ATM P SENSOR17 UNKNOWN 18 UNKNOWN19 UNKNOWN20 UNKNOWN21 UNKNOWN 22 UNKNOWN23 UNKNOWN24 UNKNOWN25 UNKNOWN 26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN 30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN 34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN38 UNKNOWN39 UNKNOWN40 UNKNOWN I72A00SEP 14, 2022 2:03 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 9 87 FILL VRL UDC VAC 36.0 GALLONS 10 87 PRODUCT LINE VAC 36.0 GALLONS 11 87 STPSUMP-FILLCNCT 36.0 GALLONS 12 91FILL-VENT-CONTSUMP 36.0 GALLONS 13 91 PRODUCT LINE VAC 36.0 GALLONS 14 91 STPSUMP-FILLCNCT 36.0 GALLONS IV4E00SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC IV4F00SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 IV4000SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 VAPOR PROCESSOR TYPENONE IV4700SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 ASSESSMENT TIMESTART TIME: 6:00 AMTIME DELAY MINUTES: 1 IV5200SEP 14, 2022 2:03 PM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 ACCEPT HIGH ORVR: YES IV4A00 SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 06 BLEND3 02 02 02 01 06 BLEND3 03 03 03 02 06 BLEND3 04 04 04 02 06 BLEND3 05 05 05 03 06 BLEND3 06 06 06 03 06 BLEND3 07 07 07 04 06 BLEND3 08 08 08 04 06 BLEND3 IV4B00SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 00/01 09/01 02/01 xx/xx02 01 00/02 09/02 02/02 xx/xx03 02 00/03 09/03 02/03 xx/xx 04 02 00/04 09/04 02/04 xx/xx05 03 00/05 09/05 02/05 xx/xx06 03 00/06 09/06 02/06 xx/xx07 04 00/07 09/07 02/07 xx/xx 08 04 00/08 09/08 02/08 xx/xx IV4900SEP 14, 2022 2:03 PM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 LABEL TABLE ID LABEL01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000SEP 14, 2022 2:03 PM ISD VERSION: 01.07 Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry