Loading...
HomeMy WebLinkAboutFMC 2022 #2Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10134205 11/2/2022 Jaco #3362 Fastrip #633 6401 South H Street Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2022 Veeder Root B47853 7/30/2024 OPW 0148613 8/21/2024 11/2/2022 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 Unl STP L2 208 Unl Fill L3 303 Unl Ann L4 208 Prem STP L5 208 Prem Fill L6 303 Prem Ann L7 208 Dsl STP L8 208 Dsl Fill L9 303 Dsl Ann L10 208 Disp 1-2 L11 208 Disp 3-4 L12 208 Disp 5-6 L13 208 Disp 7-8 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V Unl T2 FX1V Prem T3 FX1DV Dsl Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. FVAL3 STPL1L212,000 GALLON87 UNLEADED AL6 STPL4L5 AL9 STPL7L8 V F F 12L1056L12 34L1178L13 NOPARKING EXISTING BUILDING 12,000 GALLONPREMIUM 12,000 GALLONDIESEL PRICE SIGNDUMPSTERCATCHBASIN W G H W SOUTH H ST.PANAMA LN.PROPERTY LINE STORAGE CONTAINER130'130'109.98'110.11' N LEGEND L1 87 STP L2 87 FILL L3 87 ANNULAR L4 91 STP L5 91 FILL L6 91 ANNULAR L7 DSL STP L8 DSL FILL L9 DSL ANNULAR L10 UDC 1 - 2 L11 UDC 3 - 4 L12 UDC 5 - 6 L13 UDC 7 - 8 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT AUTOMATIC TANK GAUGE CIRCUIT BREAKER UST ELECTRICAL PANEL AIR AND WATER HAZWASTE DRUM W G A H P V SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 1"=10'-0" INCHES012 SHEET SIZE 22 X 34 6401 S H ST. BAKERSFIELD, CA 93304 PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-003024 CERS ID 10134205 FASTRIP #3362 6401 S H ST. BAKERSFIELD, CA 93304 01/23/17 REV.S H ST.PANAMA LN. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #3362 Fastrip #6336401 South H StreetBakersfield101342053-47-8MPD MPD MPD MPD 1-25-6ProductProductProductProductAaron Perrigo Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10134205 11/2/2022 Jaco #3362 Fastrip #633 6401 South H Street Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2022 FFS 1010993708 7/10/2024 Lake Test All 3 fill spill buckets 11/2/2022 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. Unl PhilTite Prem PhilTite Dsl PhilTite Jaco 3362 Setup Responses Received: 200 FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 NOV 2, 2022 9:02 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 4802 39.55 0.8 73.3 6880 2 PREMIUM 6618 50.81 0.0 75.8 5064 3 DIESEL 3184 29.18 0.0 81.5 8498 I90500 NOV 2, 2022 9:02 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 NOV 2, 2022 9:02 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 NOV 2, 2022 9:02 AM SHIFT TIME 1 : 6:00 AM I50202 NOV 2, 2022 9:02 AM SHIFT TIME 2 : DISABLED I50203 NOV 2, 2022 9:02 AM SHIFT TIME 3 : DISABLED I50204 NOV 2, 2022 9:02 AM SHIFT TIME 4 : DISABLED I54600 NOV 2, 2022 9:02 AM TANK PER TST NEEDED WRN: DISABLED I54900 NOV 2, 2022 9:02 AM TANK ANN TST NEEDED WRN: DISABLED I55300 NOV 2, 2022 9:02 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 NOV 2, 2022 9:02 AM LINE PER TST NEEDED WRN: DISABLED I55900 NOV 2, 2022 9:02 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 NOV 2, 2022 9:02 AM PRINT TC VOLUMES ENABLED I50E00 NOV 2, 2022 9:02 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 NOV 2, 2022 9:02 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 NOV 2, 2022 9:02 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 NOV 2, 2022 9:03 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 NOV 2, 2022 9:03 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 1 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 NOV 2, 2022 9:03 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 NOV 2, 2022 9:03 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 NOV 2, 2022 9:03 AM TANK CHART SECURITY DISABLED I5BD00 NOV 2, 2022 9:03 AM CUSTOM ALARM LABELS DISABLED I56000 NOV 2, 2022 9:03 AM MASS/DENSITY DISABLED I88101 NOV 2, 2022 9:03 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 NOV 2, 2022 9:03 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 NOV 2, 2022 9:03 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 NOV 2, 2022 9:03 AM I88105 NOV 2, 2022 9:03 AM I88106 NOV 2, 2022 9:03 AM I52000 NOV 2, 2022 9:03 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUN 24, 2019 DISABLED 2 ON DATE JUN 24, 2019 DISABLED 3 ON DATE JUN 24, 2019 DISABLED 4 ON DATE JUN 24, 2019 DISABLED 5 ON DATE JUN 24, 2019 DISABLED 6 ON DATE JUN 24, 2019 DISABLED 7 ON DATE JUN 24, 2019 DISABLED 8 ON DATE JUN 24, 2019 DISABLED I60100 NOV 2, 2022 9:03 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 NOV 2, 2022 9:03 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 NOV 2, 2022 9:03 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 NOV 2, 2022 9:03 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 NOV 2, 2022 9:03 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 92.00 2 PREMIUM 92.00 3 DIESEL 92.00 4 0.00 I60A00 NOV 2, 2022 9:03 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 11682 2 PREMIUM 1 PT 11682 3 DIESEL 1 PT 11682 4 1 PT 0 I60400 NOV 2, 2022 9:03 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 11682 2 PREMIUM 11682 3 DIESEL 11682 4 0 I60500 NOV 2, 2022 9:03 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 11682 0 0 0 2 PREMIUM 11682 0 0 0 3 DIESEL 11682 0 0 0 4 0 0 0 0 I60600 NOV 2, 2022 9:03 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 PREMIUM 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 NOV 2, 2022 9:03 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 NOV 2, 2022 9:03 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 PREMIUM 4.0 IN. 3 DIESEL 4.0 IN. I62700 NOV 2, 2022 9:03 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 I64200 NOV 2, 2022 9:03 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 PREMIUM LOW 3 DIESEL LOW I62400 NOV 2, 2022 9:03 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 NOV 2, 2022 9:03 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11682 2 PREMIUM 11682 3 DIESEL 11682 4 0 I62300 NOV 2, 2022 9:03 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10514 2 PREMIUM 10514 3 DIESEL 10514 4 0 I62200 NOV 2, 2022 9:03 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11098 2 PREMIUM 11098 3 DIESEL 11098 4 0 I62900 NOV 2, 2022 9:03 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1168 2 PREMIUM 1168 3 DIESEL 1168 4 0 I62100 NOV 2, 2022 9:03 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1200 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62600 NOV 2, 2022 9:03 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 NOV 2, 2022 9:03 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I60800 NOV 2, 2022 9:03 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 9.00 2 PREMIUM 8.00 3 DIESEL 0.00 4 0.00 I60B00 NOV 2, 2022 9:03 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 2, 2022 9:03 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 NOV 2, 2022 9:03 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 NOV 2, 2022 9:03 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62A00 NOV 2, 2022 9:03 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62C00 NOV 2, 2022 9:03 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 NOV 2, 2022 9:03 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 NOV 2, 2022 9:03 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 NOV 2, 2022 9:03 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 NOV 2, 2022 9:03 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 NOV 2, 2022 9:03 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63A00 NOV 2, 2022 9:03 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 NOV 2, 2022 9:03 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK FEB 6, 2007 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 NOV 2, 2022 9:03 AM CSLD PROBABLITY OF DETECTION I61400 NOV 2, 2022 9:03 AM CSLD CLIMATE FACTOR I61600 NOV 2, 2022 9:03 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 NOV 2, 2022 9:03 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 NOV 2, 2022 9:03 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 2, 2022 9:03 AM CSLD REPORT ONLY I62B00 NOV 2, 2022 9:03 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 PREMIUM ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 NOV 2, 2022 9:03 AM LEAK TEST REPORT FORMAT: NORMAL I63400 NOV 2, 2022 9:03 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 NOV 2, 2022 9:03 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 NOV 2, 2022 9:03 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 NOV 2, 2022 9:03 AM I77700 NOV 2, 2022 9:03 AM I77800 NOV 2, 2022 9:03 AM I78C00 NOV 2, 2022 9:03 AM I78300 NOV 2, 2022 9:03 AM I78F00 NOV 2, 2022 9:03 AM I78700 NOV 2, 2022 9:03 AM I70200 NOV 2, 2022 9:03 AM LIQUID LABEL DEVICE LABEL 1 UNL STP 2 UNL FILL 3 UNL ANN 4 PNL STP 5 PNL FILL 6 PNL ANN 7 DSL STP 8 DSL FILL 9 DSL ANN 10 DISP 1-2 11 DISP 3-4 12 DISP 5-6 13 DISP 7-8 14 15 16 I70300 NOV 2, 2022 9:03 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL STP TRI-STATE (SINGLE FLOAT) 2 UNL FILL TRI-STATE (SINGLE FLOAT) 3 UNL ANN DUAL POINT HYDROSTATIC 4 PNL STP TRI-STATE (SINGLE FLOAT) 5 PNL FILL TRI-STATE (SINGLE FLOAT) 6 PNL ANN DUAL POINT HYDROSTATIC 7 DSL STP TRI-STATE (SINGLE FLOAT) 8 DSL FILL TRI-STATE (SINGLE FLOAT) 9 DSL ANN DUAL POINT HYDROSTATIC 10 DISP 1-2 TRI-STATE (SINGLE FLOAT) 11 DISP 3-4 TRI-STATE (SINGLE FLOAT) 12 DISP 5-6 TRI-STATE (SINGLE FLOAT) 13 DISP 7-8 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 NOV 2, 2022 9:03 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL STP STP SUMP 2 UNL FILL PIPING SUMP 3 UNL ANN ANNULAR SPACE 4 PNL STP STP SUMP 5 PNL FILL PIPING SUMP 6 PNL ANN ANNULAR SPACE 7 DSL STP STP SUMP 8 DSL FILL PIPING SUMP 9 DSL ANN ANNULAR SPACE 10 DISP 1-2 DISPENSER PAN 11 DISP 3-4 DISPENSER PAN 12 DISP 5-6 DISPENSER PAN 13 DISP 7-8 DISPENSER PAN 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 NOV 2, 2022 9:03 AM I74300 NOV 2, 2022 9:03 AM I74400 NOV 2, 2022 9:03 AM I74700 NOV 2, 2022 9:03 AM I74800 NOV 2, 2022 9:03 AM I74900 NOV 2, 2022 9:03 AM I7BC00 NOV 2, 2022 9:03 AM I80200 NOV 2, 2022 9:03 AM I80300 NOV 2, 2022 9:03 AM I80400 NOV 2, 2022 9:03 AM I80700 NOV 2, 2022 9:03 AM RELAY LABEL DEVICE LABEL 1 POS SHUT DOWN 2 OVERFILL ALARM 3 4 I80900 NOV 2, 2022 9:03 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 POS SHUT DOWN NORMALLY CLOSED 2 OVERFILL ALARM NORMALLY OPEN 3 NORMALLY OPEN 4 NORMALLY OPEN I80B00 NOV 2, 2022 9:03 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 POS SHUT DOWN 1 2 OVERFILL ALARM NONE 3 NONE 4 NONE I80A00 NOV 2, 2022 9:03 AM RELAY TYPE RELAY DESIGNATION TYPE 1 POS SHUT DOWN STANDARD 2 OVERFILL ALARM STANDARD 3 STANDARD 4 STANDARD I80C00 NOV 2, 2022 9:03 AM I80800 NOV 2, 2022 9:03 AM RELAY SETUP REPORT R 1:POS SHUT DOWN TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 1:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 1:SHORT ALARM L 4:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 3: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 NOV 2, 2022 9:04 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 NOV 2, 2022 9:04 AM I72300 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 1-2 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 F-M 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 VAPOR PROCESSOR TYPE NONE IV4700 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 ACCEPT HIGH ORVR: YES IV4A00 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 33 01 01 01 BLEND3 02 34 02 01 01 BLEND3 03 35 03 02 01 BLEND3 04 00 04 02 01 BLEND3 05 01 05 03 01 BLEND3 06 02 06 03 01 BLEND3 07 03 07 04 01 BLEND3 08 04 08 04 01 BLEND3 IV4B00 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 00 02 02/04 03/04 09/04 xx/xx 01 03 02/05 03/05 09/05 xx/xx 02 03 02/06 03/06 09/06 xx/xx 03 04 02/07 03/07 09/07 xx/xx 04 04 02/08 03/08 09/08 xx/xx 33 01 02/01 03/01 09/01 xx/xx 34 01 02/02 03/02 09/02 xx/xx 35 02 02/03 03/03 09/03 xx/xx IV4900 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 NOV 2, 2022 9:04 AM ISD VERSION: 01.07 Jaco 3362 Alarm History Responses Received: I10200 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39650 39484 2 4 PROBE / G.T. 164808 164532 3 INTERSTITIAL BD 202695 202450 4 INTERSTITIAL BD 202877 202473 5 UNUSED 10023974 9975248 6 UNUSED 10003811 9955156 7 UNUSED 9999355 9956455 8 UNUSED 10000403 9954694 9 UNUSED 9995811 9946386 10 RELAY BOARD 14992 14992 11 UNUSED 10000180 9954792 12 UNUSED 9998170 9958643 13 UNUSED 9999372 9947794 14 UNUSED 9991508 9950853 15 UNUSED 9998345 9954858 16 UNUSED 9995178 9952459 COMM 1 RS232 SERIAL BD 14992 15014 COMM 2 RS232 SERIAL BD 15102 15103 COMM 3 ELEC DISP INT. 101715 101687 COMM 4 UNUSED 10002059 9959831 COMM 5 UNUSED 9996204 9953824 COMM 6 UNUSED 9995483 9952041 I90200 NOV 2, 2022 9:04 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 2 PIPE UNL FILL FUEL ALARM CLEAR 10-12-22 9:41AM L 2 PIPE UNL FILL FUEL ALARM ALARM 10-09-22 5:46PM T 2 TANK PREMIUM OVERFILL ALARM CLEAR 10-03-22 4:35PM T 2 TANK PREMIUM OVERFILL ALARM ALARM 10-03-22 4:31PM L 9 ANNULAR DSL ANN LOW LIQUID ALARM CLEAR 8-31-22 4:43PM L 9 ANNULAR DSL ANN LOW LIQUID ALARM ALARM 8-31-22 4:39PM L 9 ANNULAR DSL ANN LOW LIQUID ALARM CLEAR 8-31-22 4:39PM L 9 ANNULAR DSL ANN LOW LIQUID ALARM ALARM 8-31-22 4:38PM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-31-22 11:36AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-31-22 11:22AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-31-22 11:20AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-31-22 11:20AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-31-22 10:31AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-31-22 10:31AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-31-22 9:34AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-30-22 11:33PM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-30-22 9:27PM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-30-22 9:26PM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-30-22 8:49PM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-30-22 8:38PM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-30-22 9:54AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-30-22 5:59AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-30-22 5:47AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-30-22 5:47AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 9:22AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 9:22AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 9:22AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 9:21AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 9:17AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 9:17AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 9:17AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 9:17AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 8:40AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 8:40AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 8:31AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 8:31AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-29-22 6:42AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-29-22 6:42AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-28-22 2:39AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-28-22 2:39AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-27-22 6:20AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-27-22 6:20AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-26-22 8:21AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-26-22 8:21AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-26-22 8:16AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-26-22 8:14AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-26-22 8:13AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-26-22 8:11AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM CLEAR 8-26-22 8:09AM L 9 ANNULAR DSL ANN HIGH LIQUID ALARM ALARM 8-26-22 8:09AM I11200 NOV 2, 2022 9:04 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-31-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 10-28-22 4:07PM OTHER ISD GROSS PRES WARN ALARM 10-28-22 10:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-28-22 10:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-27-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 10-27-22 10:00AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 10-26-22 11:17AM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 10-26-22 10:21AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 10-26-22 10:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-26-22 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-26-22 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-25-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 10-25-22 10:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-23-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 10-21-22 10:42AM OTHER ISD GROSS PRES WARN ALARM 10-21-22 10:02AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 10-17-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 10-16-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 10-14-22 2:47PM OTHER ISD GROSS PRES WARN ALARM 10-14-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 10-05-22 12:16PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 10-05-22 10:45AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-03-22 10:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 9-30-22 10:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 9-28-22 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 9-27-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 9-26-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-25-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-22-22 12:10PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-22-22 12:04PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 9-17-22 10:00AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-16-22 10:10PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-16-22 6:45PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 9-15-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-14-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-13-22 4:29PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-13-22 3:48PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 9-11-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 9-11-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-09-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-03-22 10:34AM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-03-22 9:51AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 8-31-22 4:45PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 8-29-22 10:01AM SYSTEM PRINTER ERROR CLEAR 8-27-22 5:48PM SYSTEM PAPER OUT CLEAR 8-27-22 5:48PM SYSTEM PRINTER ERROR ALARM 8-27-22 5:48PM SYSTEM PAPER OUT ALARM 8-27-22 5:48PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 8-24-22 11:51AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 8-24-22 10:01AM I20600 NOV 2, 2022 9:05 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUL 5, 2022 5:17 PM INVALID FUEL LEVEL OCT 26, 2022 10:21 AM OCT 5, 2022 10:45 AM SEP 22, 2022 12:04 PM TANK 2 PREMIUM OVERFILL ALARM OCT 3, 2022 4:31 PM TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 NOV 2, 2022 9:05 AM I30200 NOV 2, 2022 9:05 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 1:01 PM FUEL ALARM JUL 23, 2022 4:48 AM FUEL ALARM 2 UNL FILL OCT 9, 2022 5:46 PM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 12:54 PM FUEL ALARM 3 UNL ANN AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 12:51 PM HIGH LIQUID ALARM AUG 3, 2022 12:50 PM LOW LIQUID ALARM 4 PNL STP AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 1:02 PM FUEL ALARM JUN 21, 2022 9:41 AM FUEL ALARM 5 PNL FILL AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 12:56 PM FUEL ALARM JUN 21, 2022 9:38 AM SENSOR OUT ALARM 6 PNL ANN AUG 3, 2022 1:10 PM SENSOR OUT ALARM JUN 21, 2022 9:38 AM SENSOR OUT ALARM JUN 21, 2022 9:13 AM LOW LIQUID ALARM 7 DSL STP AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 12:58 PM FUEL ALARM JUL 13, 2022 10:09 PM FUEL ALARM 8 DSL FILL AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 12:56 PM FUEL ALARM JUN 21, 2022 9:38 AM SENSOR OUT ALARM 9 DSL ANN AUG 31, 2022 4:39 PM LOW LIQUID ALARM AUG 31, 2022 4:38 PM LOW LIQUID ALARM AUG 31, 2022 11:22 AM HIGH LIQUID ALARM 10 DISP 1-2 AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 1:05 PM FUEL ALARM JUN 21, 2022 9:38 AM SENSOR OUT ALARM 11 DISP 3-4 AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 1:03 PM FUEL ALARM JUN 21, 2022 9:38 AM SENSOR OUT ALARM 12 DISP 5-6 AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 1:04 PM FUEL ALARM AUG 3, 2022 1:04 PM FUEL ALARM 13 DISP 7-8 AUG 3, 2022 1:10 PM SENSOR OUT ALARM AUG 3, 2022 1:04 PM FUEL ALARM JUN 21, 2022 9:38 AM SENSOR OUT ALARM I31600 NOV 2, 2022 9:05 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 3 FM 3-4 4 F-M 5-6 5 FM 7-8 I40200 NOV 2, 2022 9:05 AM I40300 NOV 2, 2022 9:05 AM I34200 NOV 2, 2022 9:05 AM I34700 NOV 2, 2022 9:05 AM IV0100 NOV 2, 2022 9:05 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :WARN EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-11-01 10:01:10 A/L RATIO DEGRADATION FP 8 BLEND3 0.76 22-11-01 10:01:10 A/L RATIO DEGRADATION FP 2 BLEND3 1.42 22-10-31 10:01:18 A/L RATIO DEGRADATION FP 8 BLEND3 0.77 22-10-31 10:01:18 A/L RATIO DEGRADATION FP 2 BLEND3 1.44 22-10-30 10:01:24 A/L RATIO DEGRADATION FP 2 BLEND3 1.43 22-10-29 10:01:29 A/L RATIO DEGRADATION FP 2 BLEND3 1.46 22-10-28 10:01:29 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.59 22-10-28 10:01:29 A/L RATIO DEGRADATION FP 2 BLEND3 1.43 22-10-27 10:01:32 A/L RATIO DEGRADATION FP 8 BLEND3 0.77 22-10-27 10:01:32 A/L RATIO DEGRADATION FP 2 BLEND3 1.39 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 21-06-20 10:01:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 21-05-31 10:01:09 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 21-05-31 10:01:09 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 21-03-31 10:01:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.75 19-09-26 10:01:23 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-09-05 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 19-07-13 09:22:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 19-03-06 09:54:16 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 19-03-06 09:54:16 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 19-01-12 09:24:35 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-10-29 10:01:29 READINESS ISD:PP EVR:PP ISD & EVR READY 22-10-28 16:07:22 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 22-10-28 10:01:29 READINESS ISD:PP EVR:PF CHECK EVR SYSTEM 22-10-28 07:18:46 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-10-28 07:18:46 ISD STARTUP 22-10-28 07:17:55 ISD SHUTDOWN 22-10-21 10:42:03 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 22-10-14 14:47:01 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 22-09-26 10:01:11 READINESS ISD:PP EVR:PP ISD & EVR READY 22-09-25 10:58:24 READINESS ISD:PP EVR:NN EVR READINESS PENDING Jaco 3362 Alarm History After Responses Received: I10200 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39650 39540 2 4 PROBE / G.T. 164808 164591 3 INTERSTITIAL BD 202695 202447 4 INTERSTITIAL BD 202877 202724 5 UNUSED 10023974 9948728 6 UNUSED 10003811 9944316 7 UNUSED 9999355 9939949 8 UNUSED 10000403 9942654 9 UNUSED 9995811 9935828 10 RELAY BOARD 14992 14992 11 UNUSED 10000180 9947134 12 UNUSED 9998170 9937402 13 UNUSED 9999372 9940239 14 UNUSED 9991508 9937734 15 UNUSED 9998345 9942456 16 UNUSED 9995178 9939752 COMM 1 RS232 SERIAL BD 14992 15014 COMM 2 RS232 SERIAL BD 15102 15125 COMM 3 ELEC DISP INT. 101715 101793 COMM 4 UNUSED 10002059 9946934 COMM 5 UNUSED 9996204 9940328 COMM 6 UNUSED 9995483 9944917 I90200 NOV 2, 2022 11:16 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 8 PIPE DSL FILL FUEL ALARM CLEAR 11-02-22 10:50AM L 8 PIPE DSL FILL FUEL ALARM ALARM 11-02-22 10:50AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT FAIL CLEAR 11-02-22 10:04AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT FAIL ALARM 11-02-22 10:01AM L 2 PIPE UNL FILL SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 8 PIPE DSL FILL SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 7 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 4 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 3 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 5 PIPE PNL FILL SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L 9 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 11-02-22 9:43AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 11-02-22 9:43AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 11-02-22 9:43AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 11-02-22 9:43AM L 9 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 11-02-22 9:43AM L 8 PIPE DSL FILL SENSOR OUT ALARM ALARM 11-02-22 9:43AM L 7 STP SUMP DSL STP SENSOR OUT ALARM ALARM 11-02-22 9:43AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 11-02-22 9:43AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 11-02-22 9:42AM L 4 STP SUMP PNL STP SENSOR OUT ALARM ALARM 11-02-22 9:42AM L 3 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 11-02-22 9:42AM L 2 PIPE UNL FILL SENSOR OUT ALARM ALARM 11-02-22 9:42AM L 5 PIPE PNL FILL SENSOR OUT ALARM ALARM 11-02-22 9:42AM L 1 STP SUMP UNL STP SENSOR OUT ALARM ALARM 11-02-22 9:42AM L13 DISP PAN DISP 7-8 FUEL ALARM CLEAR 11-02-22 9:38AM L13 DISP PAN DISP 7-8 FUEL ALARM ALARM 11-02-22 9:38AM L11 DISP PAN DISP 3-4 FUEL ALARM CLEAR 11-02-22 9:37AM L11 DISP PAN DISP 3-4 FUEL ALARM ALARM 11-02-22 9:37AM L10 DISP PAN DISP 1-2 FUEL ALARM CLEAR 11-02-22 9:37AM L10 DISP PAN DISP 1-2 FUEL ALARM ALARM 11-02-22 9:36AM L12 DISP PAN DISP 5-6 FUEL ALARM CLEAR 11-02-22 9:36AM L12 DISP PAN DISP 5-6 FUEL ALARM ALARM 11-02-22 9:35AM L 3 ANNULAR UNL ANN LOW LIQUID ALARM CLEAR 11-02-22 9:35AM L 3 ANNULAR UNL ANN LOW LIQUID ALARM ALARM 11-02-22 9:35AM L 3 ANNULAR UNL ANN HIGH LIQUID ALARM CLEAR 11-02-22 9:35AM L 3 ANNULAR UNL ANN LOW LIQUID ALARM CLEAR 11-02-22 9:34AM L 3 ANNULAR UNL ANN HIGH LIQUID ALARM ALARM 11-02-22 9:34AM L 3 ANNULAR UNL ANN LOW LIQUID ALARM ALARM 11-02-22 9:34AM L 6 ANNULAR PNL ANN HIGH LIQUID ALARM CLEAR 11-02-22 9:34AM L 6 ANNULAR PNL ANN LOW LIQUID ALARM CLEAR 11-02-22 9:34AM L 6 ANNULAR PNL ANN HIGH LIQUID ALARM ALARM 11-02-22 9:34AM L 6 ANNULAR PNL ANN LOW LIQUID ALARM ALARM 11-02-22 9:34AM L 9 ANNULAR DSL ANN LOW LIQUID ALARM CLEAR 11-02-22 9:33AM L 9 ANNULAR DSL ANN LOW LIQUID ALARM ALARM 11-02-22 9:33AM I11200 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-02-22 10:04AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 11-02-22 10:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-31-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 10-28-22 4:07PM OTHER ISD GROSS PRES WARN ALARM 10-28-22 10:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-28-22 10:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-27-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 10-27-22 10:00AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 10-26-22 11:17AM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 10-26-22 10:21AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 10-26-22 10:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-26-22 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-26-22 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-25-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 10-25-22 10:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-23-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 10-21-22 10:42AM OTHER ISD GROSS PRES WARN ALARM 10-21-22 10:02AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 10-17-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 10-16-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 10-14-22 2:47PM OTHER ISD GROSS PRES WARN ALARM 10-14-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 10-05-22 12:16PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 10-05-22 10:45AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-03-22 10:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 9-30-22 10:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 9-28-22 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 9-27-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 9-26-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-25-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-22-22 12:10PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-22-22 12:04PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 9-17-22 10:00AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-16-22 10:10PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-16-22 6:45PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 9-15-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-14-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-13-22 4:29PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-13-22 3:48PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 9-11-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 9-11-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-09-22 10:01AM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 9-03-22 10:34AM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 9-03-22 9:51AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 8-31-22 4:45PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 8-29-22 10:01AM SYSTEM PRINTER ERROR CLEAR 8-27-22 5:48PM SYSTEM PAPER OUT CLEAR 8-27-22 5:48PM SYSTEM PRINTER ERROR ALARM 8-27-22 5:48PM SYSTEM PAPER OUT ALARM 8-27-22 5:48PM I20600 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUL 5, 2022 5:17 PM INVALID FUEL LEVEL OCT 26, 2022 10:21 AM OCT 5, 2022 10:45 AM SEP 22, 2022 12:04 PM TANK 2 PREMIUM OVERFILL ALARM OCT 3, 2022 4:31 PM TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 NOV 2, 2022 11:16 AM I30200 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP NOV 2, 2022 9:42 AM SENSOR OUT ALARM NOV 2, 2022 9:30 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 2 UNL FILL NOV 2, 2022 9:42 AM SENSOR OUT ALARM NOV 2, 2022 9:31 AM FUEL ALARM OCT 9, 2022 5:46 PM FUEL ALARM 3 UNL ANN NOV 2, 2022 9:42 AM SENSOR OUT ALARM NOV 2, 2022 9:35 AM LOW LIQUID ALARM NOV 2, 2022 9:34 AM HIGH LIQUID ALARM 4 PNL STP NOV 2, 2022 9:42 AM SENSOR OUT ALARM NOV 2, 2022 9:30 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 5 PNL FILL NOV 2, 2022 9:42 AM SENSOR OUT ALARM NOV 2, 2022 9:31 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 6 PNL ANN NOV 2, 2022 9:42 AM SENSOR OUT ALARM NOV 2, 2022 9:34 AM HIGH LIQUID ALARM NOV 2, 2022 9:34 AM LOW LIQUID ALARM 7 DSL STP NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:28 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 8 DSL FILL NOV 2, 2022 10:50 AM FUEL ALARM NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:32 AM FUEL ALARM 9 DSL ANN NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:33 AM LOW LIQUID ALARM NOV 2, 2022 9:33 AM HIGH LIQUID ALARM 10 DISP 1-2 NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:36 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 11 DISP 3-4 NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:37 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 12 DISP 5-6 NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:35 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM 13 DISP 7-8 NOV 2, 2022 9:43 AM SENSOR OUT ALARM NOV 2, 2022 9:38 AM FUEL ALARM AUG 3, 2022 1:10 PM SENSOR OUT ALARM I31600 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 3 FM 3-4 4 F-M 5-6 5 FM 7-8 I40200 NOV 2, 2022 11:16 AM I40300 NOV 2, 2022 11:16 AM I34200 NOV 2, 2022 11:16 AM I34700 NOV 2, 2022 11:16 AM IV0100 NOV 2, 2022 11:16 AM FASTRIP 3362 6401 S H ST BAKERSFIELD,CA93304 661-831-4709 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :FAIL EVR VAPOR COLLECTION :FAIL EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-11-02 10:01:09 A/L RATIO DEGRADATION FP 8 BLEND3 0.78 22-11-01 10:01:10 A/L RATIO DEGRADATION FP 8 BLEND3 0.76 22-11-01 10:01:10 A/L RATIO DEGRADATION FP 2 BLEND3 1.42 22-10-31 10:01:18 A/L RATIO DEGRADATION FP 8 BLEND3 0.77 22-10-31 10:01:18 A/L RATIO DEGRADATION FP 2 BLEND3 1.44 22-10-30 10:01:24 A/L RATIO DEGRADATION FP 2 BLEND3 1.43 22-10-29 10:01:29 A/L RATIO DEGRADATION FP 2 BLEND3 1.46 22-10-28 10:01:29 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.59 22-10-28 10:01:29 A/L RATIO DEGRADATION FP 2 BLEND3 1.43 22-10-27 10:01:32 A/L RATIO DEGRADATION FP 8 BLEND3 0.77 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-11-02 10:01:09 A/L RATIO DEGRADATION FP 2 BLEND3 1.43 21-06-20 10:01:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 21-05-31 10:01:09 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 21-05-31 10:01:09 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 21-03-31 10:01:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.75 19-09-26 10:01:23 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-09-05 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 19-07-13 09:22:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 19-03-06 09:54:16 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 19-03-06 09:54:16 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-11-02 10:04:59 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 22-11-02 10:04:52 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED 22-11-02 10:04:18 PUMPS MANUALLY RE-ENABLED 22-11-02 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 22-11-02 10:01:09 A/L RATIO GROSS DEGRADATION DISABLED FP 02 BLEND3 22-11-02 09:42:01 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-11-02 09:42:01 ISD STARTUP 22-11-02 09:41:22 ISD SHUTDOWN 22-10-29 10:01:29 READINESS ISD:PP EVR:PP ISD & EVR READY 22-10-28 16:07:22 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED