HomeMy WebLinkAboutFMC 2022Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ☐Installation ☐Repair ☒12 Month 1. FACILITY INFORMATION CERS ID 10022869 Certification Date 10-12-2022 Facility Name Circle k Facility Address 5634 Stine rd. City Bakersfield ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification B&T SERVICE STATION CONTRACTORS Phone 805.929.8944 Mailing Address 630 S FRONTAGE RD, NIPOMO, CA 93444 Service Technician Performing Test ryan wittenberg Contractor/Tank Tester License Number 902034 ICC Number 10167080 ICC Expiration Date 5-18-2024 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date LDT-890 (5177) 5-23-2024 Veeder root tls 350 tech c32708 9-28-2024 4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date 10-12-2022 Total # of Pages 93313 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Veeder root Model of Monitoring System Control Panel TLS350 Software Version Installed 336.02 Attach the post-certification reports if the monitoring system is capable of generating either; ☒Monitoring System Set-up ☒ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ☒ ☐ Secondary containment systems are free of damage, debris, or liquid? ☒ ☐ Are the audible and visual alarms operational? ☒ ☐ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ☒ ☐ ☐ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ☒ ☐ ☐ The monitoring system set-up was reviewed, and proper settings confirmed? ☒ ☐ ☐ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ☒ ☐ ☐ Does the flow of fuel stop at the dispenser if a release is detected in the under-dispenser containment? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ☒ Sump ☐ UDC ☒ ☐ ☐ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ☐ ☐ ☒ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail L1 409 87 annular ☒ ☐ L2 208 87 STP ☒ ☐ L3 409 91 annular ☒ ☐ L4 208 91 STP ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ☐ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ☒ 3 GPH ☐ 0.1 GPH ☐ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ☒ ☐ ☐ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ☐ ☐ ☒ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ☒ ☐ ☐ For electronic LLDs, does the turbine automatically shut off when a release is detected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ☐ ☐ ☒ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ☐ ☐ ☒ Were all items on the equipment manufacturer’s maintenance checklist completed? ☒ ☐ ☐ Were all LLDs confirmed operational within regulatory requirements? ☒ ☐ ☐ LLD ID LLD Model Lines Monitored Pass Fail LD2000 87 ☒ ☐ LD2000 91 ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ☐Check this box if tank gauging is used only for inventory control. ☐Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ☐☐☐ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ☐☐☐ Was accuracy of system’s product level readings tested? ☐☐☐ Was accuracy of system’s water level readings tested? ☐☐☐ Were all probes reinstalled properly? ☐☐☐ Were all items on the equipment manufacturer’s maintenance checklist completed? ☐☐☐ Probe ID Probe Model Tanks Monitored Pass Fail ☐☐ ☐☐ ☐ ☐ ☐ ☐ ☐☐ ☐ ☐ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. X Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ☐Installation ☐Repair ☒12 Month 1. FACILITY INFORMATION CERS ID 10022869 Test Date 10-12-2022 Facility Name Circle k Facility Address 5634 Stine rd City Bakersfield ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test B&T SERVICE STATION CONTRACTORS Phone 805.929.8944 Mailing Address 630 S FRONTAGE RD, NIPOMO, CA 93444 Service Technician Performing Test RYAN WITTENBERG Contractor/Tank Tester License Number 902034 ICC Number 10167080 ICC Expiration Date 5-18-2024 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date FFS PRO STAGE II 1026443711 7-29-2024 4.TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 1 HR HYDRO 87 FILL 1 HR HYDRO 91 FILL 5.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 10-12-2022 Total # of Pages 93313 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6.SPILL CONTAINER DETAILS Test Method Developed by ☒ Manufacturer ☐ Industry Standard ☐ Professional Engineer Test Type ☐Pressure ☐Vacuum ☒Hydrostatic Tank ID 87 91 Spill Container Manufacturer: OPW OPW Method of Cathodic Protection ☒Nonmetallic ☐Other ☒Nonmetallic ☐Other ☐Nonmetallic ☐Other ☐Nonmetallic ☐Other Is the spill container minimum capacity five gallons excluding riser volume? ☒Yes ☐No* ☒Yes ☐No* ☐Yes ☐No* ☐Yes ☐No* Method to keep spill container empty ☒Drain ☐Pump ☐Other ☒Drain ☐Pump ☐Other ☐Drain ☐Pump ☐Other ☐Drain ☐Pump ☐Other Spill Container Test Results ☐Pass ☒Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ☐Nonmetallic ☐Other ☐Nonmetallic ☐Other ☐Nonmetallic ☐Other ☐Nonmetallic ☐Other Is the spill container minimum capacity five gallons excluding riser volume? ☐Yes ☐No* ☐Yes ☐No* ☐Yes ☐No* ☐Yes ☐No* Method to keep spill container empty ☐Drain ☐Pump ☐Other ☐Drain ☐Pump ☐Other ☐Drain ☐Pump ☐Other ☐Drain ☐Pump ☐Other Spill Container Test Results ☐Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail 1 8.COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. 87 SPILL BUCKET FAILED HYDROSTATIC TEST. WILL NEED TO REPLACE AND RETEST. file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] Responses Received: 200CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 OCT 12, 2022 3:42 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL-REG(005) 8471 66.97 0.0 82.1 5954 2 UNL-PREM 8898 81.31 0.0 85.8 2951 I90500OCT 12, 2022 3:42 PMSOFTWARE REVISION LEVELVERSION 336.02SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500OCT 12, 2022 3:42 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S.SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMON DD YYYY HH:MM:SS xM I50201OCT 12, 2022 3:42 PM SHIFT TIME 1 : 5:00 AM file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I50202OCT 12, 2022 3:42 PM SHIFT TIME 2 : DISABLED I50203OCT 12, 2022 3:42 PM SHIFT TIME 3 : DISABLED I50204OCT 12, 2022 3:42 PM SHIFT TIME 4 : DISABLED I54600OCT 12, 2022 3:42 PM TANK PER TST NEEDED WRN: DISABLED I54900OCT 12, 2022 3:42 PM TANK ANN TST NEEDED WRN: DISABLED I55300OCT 12, 2022 3:42 PM LINE RE-ENABLE METHODPASS LINE TEST I55600OCT 12, 2022 3:42 PM LINE PER TST NEEDED WRN: DISABLED I55900OCT 12, 2022 3:42 PM LINE ANN TST NEEDED WRN: DISABLED file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I50D00OCT 12, 2022 3:42 PM PRINT TC VOLUMES ENABLED I50E00OCT 12, 2022 3:42 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00OCT 12, 2022 3:42 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400OCT 12, 2022 3:42 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01OCT 12, 2022 3:42 PM DAYLIGHT SAVING TIME ENABLED ON I51B00OCT 12, 2022 3:42 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I51600OCT 12, 2022 3:42 PM RE-DIRECT LOCAL PRINTOUTDISABLED I50400OCT 12, 2022 3:42 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900OCT 12, 2022 3:42 PM TANK CHART SECURITYDISABLED I5BD00OCT 12, 2022 3:42 PM CUSTOM ALARM LABELS DISABLED I56000OCT 12, 2022 3:42 PM MASS/DENSITY DISABLED I88101OCT 12, 2022 3:42 PM file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITYCODE : DISABLED I88102 OCT 12, 2022 3:42 PMPORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITYCODE : DISABLED I88103 OCT 12, 2022 3:42 PMPORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITYCODE : DISABLED I88104 OCT 12, 2022 3:42 PM I88105OCT 12, 2022 3:42 PM PORT SETTINGS: COMM BOARD : 5 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I88106OCT 12, 2022 3:42 PM I52000OCT 12, 2022 3:42 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUN 6, 2008 DISABLED 2 ON DATE JUN 6, 2008 DISABLED 3 ON DATE JUN 6, 2008 DISABLED 4 ON DATE JUN 6, 2008 DISABLED 5 ON DATE JUN 6, 2008 DISABLED 6 ON DATE JUN 6, 2008 DISABLED 7 ON DATE JUN 6, 2008 DISABLED 8 ON DATE JUN 6, 2008 DISABLED I60100OCT 12, 2022 3:42 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL-REG(005) ON 2 UNL-PREM ON 3 OFF 4 OFF I60200OCT 12, 2022 3:42 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL-REG(005) 2 UNL-PREM 3 4 I60300OCT 12, 2022 3:42 PM TANK PRODUCT CODE TANK PRODUCT LABEL file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 1 UNL-REG(005) A 2 UNL-PREM B 3 3 4 4 I60900OCT 12, 2022 3:42 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL-REG(005) 0.000700 2 UNL-PREM 0.000700 3 0.000000 4 0.000000 I60700OCT 12, 2022 3:42 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 117.75 2 UNL-PREM 117.75 3 0.00 4 0.00 I60A00OCT 12, 2022 3:42 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL-REG(005) 1 PT 14425 2 UNL-PREM 4 PTS 11849 3 1 PT 0 4 1 PT 0 I60400OCT 12, 2022 3:42 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 2 UNL-PREM 11849 3 0 4 0 I60500OCT 12, 2022 3:42 PM file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 0 0 0 2 UNL-PREM 11849 9710 5995 2245 3 0 0 0 0 4 0 0 0 0 I60600 OCT 12, 2022 3:42 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL-PREM 11849 0 0 0 0 9710 0 0 0 0 5995 0 0 0 0 2245 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500OCT 12, 2022 3:42 PM TANK PRODUCT LABEL METER DATA 1 UNL-REG(005) NO 2 UNL-PREM NO 3 NO 4 NO I62F00 OCT 12, 2022 3:42 PM MAG PROBE FLOAT SIZE file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] TANK PRODUCT LABEL FLOAT SIZE: 1 UNL-REG(005) 4.0 IN. 2 UNL-PREM 4.0 IN. I62700OCT 12, 2022 3:42 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 2.0 2 UNL-PREM 1.5 I64200OCT 12, 2022 3:42 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL-REG(005) LOW 2 UNL-PREM LOW I62400OCT 12, 2022 3:42 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 2.5 2 UNL-PREM 2.5 I62800OCT 12, 2022 3:42 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 2 UNL-PREM 11849 3 0 4 0 I62300OCT 12, 2022 3:42 PM TANK OVERFILL LEVEL LIMIT file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 12983 2 UNL-PREM 10664 3 0 4 0 I62200OCT 12, 2022 3:42 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 13704 2 UNL-PREM 11257 3 0 4 0 I62900OCT 12, 2022 3:42 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 1443 2 UNL-PREM 948 3 0 4 0 I62100OCT 12, 2022 3:42 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 1084 2 UNL-PREM 900 3 0 4 0 I62600OCT 12, 2022 3:42 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 99 2 UNL-PREM 99 3 99 4 99 file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I62500OCT 12, 2022 3:42 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 99 2 UNL-PREM 99 3 99 4 99 I60800OCT 12, 2022 3:42 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 0.00 2 UNL-PREM 0.00 3 0.00 4 0.00 I60B00OCT 12, 2022 3:42 PM STICK HEIGHT OFFSET ENABLE STATUSDISABLED I60C00OCT 12, 2022 3:42 PM TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 UNL-REG(005) 0.00 2 UNL-PREM 0.00 3 0.00 4 0.00 I61200OCT 12, 2022 3:42 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL-REG(005) NONE NONE 2 UNL-PREM NONE NONE 3 NONE NONE file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 4 NONE NONE I63600OCT 12, 2022 3:42 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 0 2 UNL-PREM 0 3 0 4 0 I62A00OCT 12, 2022 3:42 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 0 2 UNL-PREM 0 3 0 4 0 I62C00OCT 12, 2022 3:42 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL-REG(005) STANDARD 2 UNL-PREM STANDARD 3 STANDARD 4 STANDARD I62D00OCT 12, 2022 3:42 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL-REG(005) GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL-PREM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100OCT 12, 2022 3:42 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL-REG(005) OFF OFF 2 UNL-PREM OFF OFF 3 OFF OFF 4 OFF OFF I63000 OCT 12, 2022 3:42 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL-REG(005) OFF 2 UNL-PREM OFF 3 OFF 4 OFF I63200OCT 12, 2022 3:42 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL-REG(005) OFF 2 UNL-PREM OFF 3 OFF 4 OFF I61000 OCT 12, 2022 3:42 PM TANK DELIVERY DELAY file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] TANK PRODUCT LABEL 1 UNL-REG(005) 10 2 UNL-PREM 10 3 10 4 10 I63A00OCT 12, 2022 3:42 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL-REG(005) 10.00% 2 UNL-PREM 10.00% 3 10.00% 4 10.00% I61100OCT 12, 2022 3:42 PM LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKJUN 6, 2008START TIME : 12:00 AMTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED I61300OCT 12, 2022 3:42 PMCSLD PROBABLITY OF DETECTION I61400OCT 12, 2022 3:42 PMCSLD CLIMATE FACTOR I61600OCT 12, 2022 3:42 PM TANK PRODUCT LABEL CAL UPDATE file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 1 UNL-REG(005) NEVER 2 UNL-PREM IMMEDIATE 3 IMMEDIATE 4 IMMEDIATE I61A00OCT 12, 2022 3:42 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL-REG(005) DISABLED 2 UNL-PREM DISABLED 3 DISABLED 4 DISABLED I61B00OCT 12, 2022 3:42 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00OCT 12, 2022 3:42 PM CSLD REPORT ONLY I62B00OCT 12, 2022 3:42 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL-REG(005) ??? 0, 0 2 UNL-PREM ??? 0, 0 3 ??? 0, 0 4 ??? 0, 0 I63300OCT 12, 2022 3:42 PM LEAK TEST REPORT FORMAT: NORMAL file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I63400OCT 12, 2022 3:42 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 0 2 UNL-PREM 0 3 0 4 0 I63500OCT 12, 2022 3:42 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 1 2 UNL-PREM 1 3 1 4 1 I63900OCT 12, 2022 3:42 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL-REG(005) END FACTOR: NONE 2 UNL-PREM END FACTOR: NONE 3 END FACTOR: NONE 4 END FACTOR: NONE I78000 OCT 12, 2022 3:42 PM file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] I77700OCT 12, 2022 3:42 PM I77800OCT 12, 2022 3:42 PM I78C00OCT 12, 2022 3:42 PM I78300OCT 12, 2022 3:42 PM I78F00OCT 12, 2022 3:42 PM I78700OCT 12, 2022 3:42 PM I70200OCT 12, 2022 3:42 PM LIQUID LABEL DEVICE LABEL 1 87 ANNULAR 2 87 TURBINE 3 91 ANNULAR 4 91 TURBINE 5 6 7 8 I70300OCT 12, 2022 3:42 PM LIQUID TYPE SENSOR LOCATION TYPE file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 TURBINE TRI-STATE (SINGLE FLOAT) 3 91 ANNULAR TRI-STATE (SINGLE FLOAT) 4 91 TURBINE TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I70400OCT 12, 2022 3:42 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87 ANNULAR ANNULAR SPACE 2 87 TURBINE STP SUMP 3 91 ANNULAR ANNULAR SPACE 4 91 TURBINE STP SUMP 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS I74200OCT 12, 2022 3:42 PM I74300OCT 12, 2022 3:42 PM I74400OCT 12, 2022 3:42 PM I74700OCT 12, 2022 3:42 PM I74800OCT 12, 2022 3:42 PM I74900 file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] OCT 12, 2022 3:42 PM I7BC00 OCT 12, 2022 3:42 PM I80200OCT 12, 2022 3:42 PM I80300 OCT 12, 2022 3:42 PM I80400OCT 12, 2022 3:42 PM I80700 OCT 12, 2022 3:42 PM RELAY LABEL DEVICE LABEL 1 87 SHUTDOWN 2 91 SHUTDOWN 3 4 FUEL ALARMS I80900OCT 12, 2022 3:42 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 SHUTDOWN NORMALLY CLOSED 2 91 SHUTDOWN NORMALLY CLOSED 3 NORMALLY OPEN 4 FUEL ALARMS NORMALLY OPEN I80B00 OCT 12, 2022 3:42 PM RELAY TANK ASSIGNMENT file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] RELAY DESIGNATION TANK 1 87 SHUTDOWN 1 2 91 SHUTDOWN 2 3 NONE 4 FUEL ALARMS NONE I80A00OCT 12, 2022 3:42 PM RELAY TYPE RELAY DESIGNATION TYPE 1 87 SHUTDOWN STANDARD 2 91 SHUTDOWN STANDARD 3 STANDARD 4 FUEL ALARMS STANDARD I80C00OCT 12, 2022 3:42 PM I80800OCT 12, 2022 3:42 PM RELAY SETUP REPORT R 1:87 SHUTDOWN TYPE: STANDARDNORMALLY CLOSED TANK #: 1 IN-TANK ALARMS T 1:HIGH WATER ALARM T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:91 SHUTDOWN TYPE: STANDARDNORMALLY CLOSED TANK #: 2 IN-TANK ALARMS T 2:HIGH WATER ALARM T 2:LOW PRODUCT ALARM T 2:PROBE OUT LIQUID SENSOR ALMS L 3:FUEL ALARM L 4:FUEL ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 3:SHORT ALARM L 4:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3: TYPE: STANDARDNORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 4:FUEL ALARMS TYPE: STANDARDNORMALLY OPEN file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] TANK #: NONE LIQUID SENSOR ALMS ALL:FUEL ALARM I79000OCT 12, 2022 3:43 PM EDIM:1 VR:349634-003-E TD:09.05.18.15.18 I79100 OCT 12, 2022 3:43 PM I72300OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DISP 1-2 AFM AIR FLOW METER02 DISP 3-4 AFM AIR FLOW METER 03 DISP 5-6 AFM AIR FLOW METER04 DISP 7-8 AFM AIR FLOW METER 05 DISP 1-2 VPS VAPOR PRESSURE06 UNKNOWN 07 UNKNOWN08 UNKNOWN 09 UNKNOWN10 UNKNOWN 11 UNKNOWN12 UNKNOWN 13 UNKNOWN14 UNKNOWN 15 UNKNOWN16 UNKNOWN 17 UNKNOWN18 UNKNOWN 19 UNKNOWN file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 20 UNKNOWN21 UNKNOWN22 UNKNOWN23 UNKNOWN24 UNKNOWN25 UNKNOWN26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN38 UNKNOWN39 UNKNOWN40 UNKNOWN IV4E00OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC IV4F00OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 IV4000OCT 12, 2022 3:43 PM file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 VAPOR PROCESSOR TYPENONE IV4700 OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 ASSESSMENT TIME START TIME: 5:00 AMTIME DELAY MINUTES: 1 IV5200 OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 ACCEPT HIGH ORVR: NO IV4A00OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 file:///F/...%20SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/VR%20Config.txt[10/13/2022 11:48:05 AM] 08 08 08 04 02 BLEND3 IV4B00OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 02/01 03/01 09/01 xx/xx02 01 02/02 03/02 09/02 xx/xx03 02 02/03 03/03 09/03 xx/xx04 02 02/04 03/04 09/04 xx/xx05 03 02/05 03/05 09/05 xx/xx06 03 02/06 03/06 09/06 xx/xx07 04 02/07 03/07 09/07 xx/xx08 04 02/08 03/08 09/08 xx/xx IV4900OCT 12, 2022 3:43 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 LABEL TABLEID LABEL01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000OCT 12, 2022 3:43 PM ISD VERSION: 01.07 file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] Responses Received: I10200OCT 12, 2022 3:40 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 9530395 9443288 2 UNUSED 9431434 9389857 3 UNUSED 9419675 9386485 4 UNUSED 9418473 9385127 5 UNUSED 9415416 9377909 6 8SMARTSENSOR BD 39404 39417 7 INTERSTITIAL BD 201647 201613 8 4 PROBE / G.T. 162844 162836 9 RELAY BOARD 14946 14952 10 UNUSED 9424284 9387815 11 UNUSED 9411119 9389625 12 UNUSED 9409081 9372720 13 UNUSED 9402926 9382406 14 UNUSED 9407022 9380494 15 UNUSED 9403701 9377964 16 UNUSED 9401174 9381069 COMM 1 ELEC DISP INT. 100746 100897 COMM 2 RS232 SERIAL BD 15007 15014 COMM 3 RS232 SERIAL BD 15027 15034 COMM 4 UNUSED 9411282 9384977 COMM 5 SERIAL SAT BD 478063 478819 COMM 6 UNUSED 9408123 9379075 I90200OCT 12, 2022 3:40 PMSOFTWARE REVISION LEVELVERSION 336.02SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] I11100OCT 12, 2022 3:40 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMEL 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 10-12-22 10:36AML 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 10-12-22 10:36AML 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 10-12-22 10:36AML 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 10-12-22 10:36AML 4 STP SUMP 91 TURBINE SENSOR OUT ALARM ALARM 10-12-22 10:35AML 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 10-12-22 10:35AML 2 STP SUMP 87 TURBINE SENSOR OUT ALARM ALARM 10-12-22 10:35AML 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 10-12-22 10:35AML 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-22 9:48AML 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-12-22 9:48AML 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-22 9:47AML 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-12-22 9:47AML 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-22 9:47AML 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-12-22 9:47AML 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 10-12-22 9:45AML 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 10-12-22 9:45AML 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-22 9:41AML 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-12-22 9:39AML 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-22 9:38AML 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-12-22 9:38AML 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-22 9:37AML 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-12-22 9:37AML 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 10-12-22 9:35AML 4 STP SUMP 91 TURBINE FUEL ALARM ALARM 10-12-22 9:34AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT FAIL CLEAR 8-09-22 7:24AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT FAIL ALARM 8-09-22 5:04AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT FAIL CLEAR 7-25-22 8:34AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT FAIL ALARM 7-25-22 5:06AML 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 7-14-22 11:07AML 4 STP SUMP 91 TURBINE FUEL ALARM ALARM 7-14-22 11:07AML 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 7-14-22 11:06AML 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 7-14-22 11:06AML 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 7-14-22 11:04AML 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 7-14-22 11:04AML 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 7-14-22 11:04AML 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 7-14-22 11:03AMs 1 OTHER DISP 1-2 AFM COMMUNICATION ALARM CLEAR 7-14-22 11:03AML 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 7-14-22 11:03AML 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 7-14-22 11:03AMs 1 OTHER DISP 1-2 AFM COMMUNICATION ALARM ALARM 7-14-22 11:01AML 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 4-14-22 10:39AML 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 4-14-22 10:39AML 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 4-14-22 10:39AML 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 4-14-22 10:39AM file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM ALARM 4-14-22 10:38AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 4-14-22 10:38AML 2 STP SUMP 87 TURBINE SENSOR OUT ALARM ALARM 4-14-22 10:38AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 4-14-22 10:38AM SYSTEM BATTERY IS OFF CLEAR 2-13-21 8:00AM SYSTEM BATTERY IS OFF ALARM 2-13-21 8:00AM I11200OCT 12, 2022 3:40 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 NON-PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-13-22 5:00AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 9-12-22 5:05AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-08-22 10:37AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 9-03-22 5:05AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 8-30-22 2:17PMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-29-22 5:05AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 8-25-22 12:28PMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-23-22 5:04AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 8-20-22 5:00AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-19-22 5:03AM OTHER ISD GROSS PRES WARN CLEAR 8-16-22 8:50AM OTHER ISD GROSS PRES WARN ALARM 8-15-22 5:04AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 8-14-22 5:00AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-13-22 5:06AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 8-09-22 7:24AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 8-09-22 5:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-04-22 5:05AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 8-03-22 5:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 8-02-22 5:05AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-02-22 5:05AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 7-29-22 8:54AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 7-29-22 8:54AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 7-29-22 5:05AMh 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 7-29-22 5:05AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 7-25-22 8:33AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 7-25-22 5:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 7-19-22 5:08AMh 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 7-18-22 5:06AM I20600 OCT 12, 2022 3:40 PM CIRCLE K 2701270 file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK ALARM HISTORY TANK 1 UNL-REG(005) TANK 2 UNL-PREM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200OCT 12, 2022 3:40 PM I30200OCT 12, 2022 3:40 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] 1 87 ANNULAR OCT 12, 2022 10:35 AM SENSOR OUT ALARM OCT 12, 2022 9:48 AM FUEL ALARM OCT 12, 2022 9:47 AM FUEL ALARM 2 87 TURBINE OCT 12, 2022 10:35 AM SENSOR OUT ALARM OCT 12, 2022 9:45 AM FUEL ALARM JUL 14, 2022 11:04 AM FUEL ALARM 3 91 ANNULAR OCT 12, 2022 10:35 AM SENSOR OUT ALARM OCT 12, 2022 9:39 AM FUEL ALARM OCT 12, 2022 9:38 AM FUEL ALARM 4 91 TURBINE OCT 12, 2022 10:35 AM SENSOR OUT ALARM OCT 12, 2022 9:34 AM FUEL ALARM JUL 14, 2022 11:07 AM FUEL ALARM I31600OCT 12, 2022 3:40 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 AFM JUL 14, 2022 11:01 AM COMMUNICATION ALARM 2 DISP 3-4 AFM 3 DISP 5-6 AFM 4 DISP 7-8 AFM 5 DISP 1-2 VPS I40200OCT 12, 2022 3:40 PM I40300 OCT 12, 2022 3:40 PM I34200OCT 12, 2022 3:40 PM file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] I34700OCT 12, 2022 3:40 PM IV0100OCT 12, 2022 3:40 PM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSISTISD TYPE: 01.07VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMSDATE TIME DESCRIPTION READING VALUE22-09-12 05:05:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.8022-09-08 05:04:36 A/L RATIO DEGRADATION FP 5 BLEND3 0.7522-09-07 05:04:46 A/L RATIO DEGRADATION FP 5 BLEND3 0.7222-09-06 05:05:22 A/L RATIO DEGRADATION FP 5 BLEND3 0.7122-09-05 05:06:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.7122-09-04 05:06:06 A/L RATIO DEGRADATION FP 5 BLEND3 0.7222-09-03 05:05:43 A/L RATIO DEGRADATION FP 5 BLEND3 0.7422-08-30 05:05:05 A/L RATIO DEGRADATION FP 5 BLEND3 0.7022-08-29 05:05:14 A/L RATIO DEGRADATION FP 5 BLEND3 0.7222-08-25 05:05:30 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 FAILURE ALARMSDATE TIME DESCRIPTION READING VALUE22-08-09 05:04:53 A/L RATIO DEGRADATION FP 6 BLEND3 0.7722-07-25 05:06:10 A/L RATIO DEGRADATION FP 6 BLEND3 0.7422-07-14 00:04:19 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD22-07-14 00:04:19 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD22-07-14 00:04:18 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD22-07-13 00:05:12 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD22-07-13 00:05:12 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD22-07-12 00:03:28 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD22-07-12 00:03:28 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD22-07-12 00:03:28 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTSDATE TIME DESCRIPTION ACTION/NAME22-10-12 10:33:48 READINESS ISD:PP EVR:NN EVR READINESS PENDING22-10-12 10:33:48 ISD STARTUP file:///F/...0SITE%20FORMS/CIRCLE%20K/2701270%20-%20STINE%20RD,%20BK/TEST%20RESULTS/2022/ALarm%20History.txt[10/13/2022 11:48:23 AM] 22-10-12 10:32:50 ISD SHUTDOWN 22-09-13 10:04:30 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED 22-09-08 10:37:30 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED 22-08-30 14:17:36 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED 22-08-25 12:28:57 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED 22-08-16 08:50:47 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 22-08-09 07:24:33 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 22-08-09 07:24:10 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED