Loading...
HomeMy WebLinkAboutFMC RESULTS 2022Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ☐Installation ☐Repair ☒12 Month 1. FACILITY INFORMATION CERS ID Certification Date 10/13/2022 Facility Name Mobil Circle K Facility Address 5600 Auburn St. City Bakersfield ZIP Code 93306 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification B&T Service Station Contractors Phone 805-929-8944 Mailing Address 630 S. Frontage Rd. Nipomo, CA 93444 Service Technician Performing Test Michael Molacek Contractor/Tank Tester License Number 902034 ICC Number 9175943 ICC Expiration Date 11/01/2023 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date Veeder Root TLS 350 Tech C27901 10/29/2022 VMI 4640 04/26/2024 4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date 10/13/2022 Total # of Pages 10023802 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Veeder Root Model of Monitoring System Control Panel TLS350 Software Version Installed 336.02 Attach the post-certification reports if the monitoring system is capable of generating either; ☒Monitoring System Set-up ☒ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ☒ ☐ Secondary containment systems are free of damage, debris, or liquid? ☒ ☐ Are the audible and visual alarms operational? ☒ ☐ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ☒ ☐ ☐ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ☒ ☐ ☐ The monitoring system set-up was reviewed, and proper settings confirmed? ☒ ☐ ☐ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ☒ ☐ ☐ Does the flow of fuel stop at the dispenser if a release is detected in the under-dispenser containment? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ☒ Sump ☒ UDC ☒ ☐ ☐ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ☒ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail L1 409 87 Annular ☒ ☐ L2 208 87 Turbine Sump ☒ ☐ L3 409 89 Annular ☒ ☐ L4 208 89 Turbine Sump ☒ ☐ L5 409 91 Annular ☒ ☐ L6 208 91 Turbine Sump ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ☐ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ☒ 3 GPH ☐ 0.1 GPH ☐ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ☒ ☐ ☐ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ☐ ☐ ☒ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ☒ ☐ ☒ For electronic LLDs, does the turbine automatically shut off when a release is detected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ☐ ☐ ☒ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ☐ ☐ ☒ Were all items on the equipment manufacturer’s maintenance checklist completed? ☒ ☐ ☐ Were all LLDs confirmed operational within regulatory requirements? ☒ ☐ ☐ LLD ID LLD Model Lines Monitored Pass Fail Q1 FX2V 87 ☒ ☐ Q2 FX2V 89 ☒ ☐ Q3 FX2V 91 ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ☒ Check this box if tank gauging is used only for inventory control. ☐ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ☐ ☐ ☐ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ☐ ☐ ☐ Was accuracy of system’s product level readings tested? ☐ ☐ ☐ Was accuracy of system’s water level readings tested? ☐ ☐ ☐ Were all probes reinstalled properly? ☐ ☐ ☐ Were all items on the equipment manufacturer’s maintenance checklist completed? ☐ ☐ ☐ Probe ID Probe Model Tanks Monitored Pass Fail ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. UDC's are monitored with stand alone sensors which were functioning properly.Tested Impact (Shear Valves) all functioning properly. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ☐Installation ☐Repair ☒12 Month 1. FACILITY INFORMATION CERS ID Test Date 10/13/2022 Facility Name Mobil Circle K Facility Address 5600 Auburn St. City Bakersfield ZIP Code 93306 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test B&T Service Station Contractors Phone 805-929-8944 Mailing Address 630 S. Frontage Rd. Nipomo, CA 93444 Service Technician Performing Test Michael Molacek Contractor/Tank Tester License Number 902034 ICC Number 9175943 ICC Expiration Date 11/1/2023 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 9175943 11/01/2023 4.TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 1 HR. Lake Test 87, 87, 91 Fills 5.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 10/13/2022 Total # of Pages 10023802 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ☒ Manufacturer ☒ Industry Standard ☐ Professional Engineer Test Type ☐ Pressure ☐ Vacuum ☒ Hydrostatic Tank ID 87 89 91 Spill Container Manufacturer: OPW OPW OPW Method of Cathodic Protection ☒ Nonmetallic ☐ Other ☒ Nonmetallic ☐ Other ☒ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other Is the spill container minimum capacity five gallons excluding riser volume? ☒ Yes ☐ No* ☒ Yes ☐ No* ☒ Yes ☐ No* ☐ Yes ☐ No* Method to keep spill container empty ☒ Drain ☐ Pump ☐ Other ☒ Drain ☐ Pump ☐ Other ☒ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other Spill Container Test Results ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☐ Pass ☐ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other Is the spill container minimum capacity five gallons excluding riser volume? ☐ Yes ☐ No* ☐ Yes ☐ No* ☐ Yes ☐ No* ☐ Yes ☐ No* Method to keep spill container empty ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other Spill Container Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. < I10100 OCT 13, 2022 11:31 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL > < I51700 OCT 13, 2022 11:31 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM > < I50F00 OCT 13, 2022 11:31 AM MON DD YYYY HH:MM:SS xM > < I60100 OCT 13, 2022 11:31 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL Premium ON 2 UNL Plus NoBlend ON 3 UNL Regular ON 4 87 UNLEADED OFF > < I60200 OCT 13, 2022 11:31 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL Premium 2 UNL Plus NoBlend 3 UNL Regular 4 87 UNLEADED > < I60300 OCT 13, 2022 11:31 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL Premium C 2 UNL Plus NoBlend B 3 UNL Regular A 4 87 UNLEADED 4 > < I60400 OCT 13, 2022 11:31 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL Premium 9684 2 UNL Plus NoBlend 9684 3 UNL Regular 9684 4 87 UNLEADED 9816 > < I60700 OCT 13, 2022 11:32 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL Premium 98.00 2 UNL Plus NoBlend 98.00 3 UNL Regular 98.00 4 87 UNLEADED 92.00 > < I60900 OCT 13, 2022 11:32 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL Premium 0.000700 2 UNL Plus NoBlend 0.000700 3 UNL Regular 0.000700 4 87 UNLEADED 0.000070 > < I61200 OCT 13, 2022 11:32 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL Premium NONE NONE 2 UNL Plus NoBlend NONE NONE 3 UNL Regular NONE NONE 4 87 UNLEADED NONE NONE > < I62100 OCT 13, 2022 11:32 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 500 2 UNL Plus NoBlend 500 3 UNL Regular 500 4 87 UNLEADED 500 > < I62200 OCT 13, 2022 11:32 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 9200 2 UNL Plus NoBlend 9200 3 UNL Regular 9200 4 87 UNLEADED 9325 > < I62300 OCT 13, 2022 11:32 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 8716 2 UNL Plus NoBlend 8716 3 UNL Regular 8716 4 87 UNLEADED 8834 > < I62400 OCT 13, 2022 11:32 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL Premium 3.0 2 UNL Plus NoBlend 3.0 3 UNL Regular 3.0 > < I62800 OCT 13, 2022 11:32 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 9684 2 UNL Plus NoBlend 9684 3 UNL Regular 9684 4 87 UNLEADED 9816 > < I62900 OCT 13, 2022 11:32 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 982 2 UNL Plus NoBlend 982 3 UNL Regular 982 4 87 UNLEADED 982 > < I70300 OCT 13, 2022 11:32 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 TURBINE TRI-STATE (SINGLE FLOAT) 3 89 ANNULAR TRI-STATE (SINGLE FLOAT) 4 89 TURBINE TRI-STATE (SINGLE FLOAT) 5 91 ANNULAR TRI-STATE (SINGLE FLOAT) 6 91 TURBINE TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) > < I20600 OCT 13, 2022 11:32 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 TANK ALARM HISTORY TANK 1 UNL Premium PROBE OUT JUL 18, 2022 3:03 PM TANK 2 UNL Plus NoBlend PROBE OUT JUL 18, 2022 3:03 PM TANK 3 UNL Regular PROBE OUT JUL 18, 2022 3:03 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 > < I30200 OCT 13, 2022 11:33 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR OCT 13, 2022 9:59 AM FUEL ALARM OCT 13, 2022 9:59 AM FUEL ALARM OCT 13, 2022 9:58 AM FUEL ALARM 2 87 TURBINE OCT 13, 2022 10:11 AM FUEL ALARM JUL 18, 2022 3:09 PM FUEL ALARM JUL 18, 2022 3:04 PM SENSOR OUT ALARM 3 89 ANNULAR OCT 13, 2022 10:04 AM FUEL ALARM OCT 13, 2022 10:03 AM FUEL ALARM OCT 13, 2022 10:01 AM FUEL ALARM 4 89 TURBINE OCT 13, 2022 10:10 AM FUEL ALARM JUL 18, 2022 3:10 PM FUEL ALARM JUL 18, 2022 3:04 PM SENSOR OUT ALARM 5 91 ANNULAR OCT 13, 2022 10:06 AM FUEL ALARM OCT 13, 2022 10:05 AM FUEL ALARM JUL 18, 2022 3:10 PM FUEL ALARM 6 91 TURBINE OCT 13, 2022 10:09 AM FUEL ALARM JUL 18, 2022 3:10 PM FUEL ALARM JUL 18, 2022 3:04 PM SENSOR OUT ALARM > < I38200 OCT 13, 2022 11:33 AM > < I90200 OCT 13, 2022 11:33 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM > < I31600 OCT 13, 2022 11:33 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 AFM 2 DISP 3-4 AFM 3 DISP 1-2 VPS > < I32300 OCT 13, 2022 11:33 AM > < I34200 OCT 13, 2022 11:33 AM > < I34700 OCT 13, 2022 11:33 AM > < I20700 OCT 13, 2022 11:33 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 TANK LEAK TEST HISTORY T 1:UNL Premium LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 2:UNL Plus NoBlend LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 3:UNL Regular LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE > < I31200 OCT 13, 2022 11:33 AM > < I38700 OCT 13, 2022 11:33 AM > < I20300 OCT 13, 2022 11:33 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 TANK 1 UNL Premium TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 2 UNL Plus NoBlend TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 3 UNL Regular TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK > < I25100 OCT 13, 2022 11:33 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 CSLD TEST RESULTS TANK PRODUCT RESULT > < I21300 OCT 13, 2022 11:33 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 DELIVERY REPORT T 1:UNL Premium INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT T 2:UNL Plus NoBlend INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT T 3:UNL Regular INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT > < I31800 OCT 13, 2022 11:33 AM > < I37400 OCT 13, 2022 11:34 AM > < I38900 OCT 13, 2022 11:34 AM > < I11100 OCT 13, 2022 11:34 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 10-13-22 10:11AM L 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 10-13-22 10:11AM L 4 STP SUMP 89 TURBINE FUEL ALARM CLEAR 10-13-22 10:10AM L 4 STP SUMP 89 TURBINE FUEL ALARM ALARM 10-13-22 10:10AM L 6 STP SUMP 91 TURBINE FUEL ALARM CLEAR 10-13-22 10:09AM L 6 STP SUMP 91 TURBINE FUEL ALARM ALARM 10-13-22 10:09AM L 5 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-13-22 10:06AM L 5 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-13-22 10:06AM L 5 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-13-22 10:06AM L 5 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-13-22 10:05AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-13-22 10:04AM L 3 ANNULAR 89 ANNULAR FUEL ALARM ALARM 10-13-22 10:04AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-13-22 10:04AM L 3 ANNULAR 89 ANNULAR FUEL ALARM ALARM 10-13-22 10:03AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-13-22 10:02AM L 3 ANNULAR 89 ANNULAR FUEL ALARM ALARM 10-13-22 10:01AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 10:00AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-13-22 9:59AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 9:59AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-13-22 9:59AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 9:59AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-13-22 9:58AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 9:58AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-13-22 9:58AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-07-22 4:15AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 10-07-22 3:02AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-04-22 8:41AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 10-04-22 8:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-04-22 8:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 10-04-22 8:12AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-01-22 4:51PM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 10-01-22 4:41PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-29-22 8:59AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-29-22 8:50AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-28-22 4:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-27-22 9:01PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-27-22 1:12PM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-27-22 1:02PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-27-22 6:25AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-27-22 6:16AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-22-22 4:38PM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-22-22 4:08PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-12-22 4:13PM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-12-22 4:03PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-07-22 8:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-07-22 8:07AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-02-22 3:24PM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-02-22 1:14PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-01-22 3:52AM E 1 OTHER B9DNHG COMMUNICATION ALARM ALARM 9-01-22 3:25AM > < I11200 OCT 13, 2022 11:34 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN CLEAR 9-22-22 3:24PM OTHER ISD GROSS PRES WARN ALARM 9-22-22 10:02AM OTHER ISD GROSS PRES WARN CLEAR 9-16-22 8:58AM OTHER ISD GROSS PRES WARN ALARM 9-15-22 10:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-02-22 9:22AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-01-22 10:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 8-27-22 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 8-26-22 10:04AM SYSTEM PRINTER ERROR CLEAR 7-30-22 11:54PM SYSTEM PAPER OUT CLEAR 7-30-22 11:54PM SYSTEM PRINTER ERROR ALARM 7-30-22 11:35PM SYSTEM PAPER OUT ALARM 7-30-22 11:35PM > < I11400 OCT 13, 2022 11:34 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 CLEARED ALARMS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 10-13-22 10:11AM L 4 STP SUMP 89 TURBINE FUEL ALARM CLEAR 10-13-22 10:10AM L 6 STP SUMP 91 TURBINE FUEL ALARM CLEAR 10-13-22 10:09AM L 5 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-13-22 10:06AM L 5 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-13-22 10:06AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-13-22 10:04AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-13-22 10:04AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-13-22 10:02AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 10:00AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 9:59AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 9:59AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-13-22 9:58AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-07-22 4:15AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-04-22 8:41AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-04-22 8:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 10-01-22 4:51PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-29-22 8:59AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-28-22 4:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-27-22 1:12PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-27-22 6:25AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-22-22 4:38PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-12-22 4:13PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-07-22 8:17AM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-02-22 3:24PM E 1 OTHER B9DNHG COMMUNICATION ALARM CLEAR 9-01-22 3:52AM OTHER ISD GROSS PRES WARN CLEAR 9-22-22 3:24PM OTHER ISD GROSS PRES WARN CLEAR 9-16-22 8:58AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-02-22 9:22AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 8-27-22 10:00AM SYSTEM PRINTER ERROR CLEAR 7-30-22 11:54PM SYSTEM PAPER OUT CLEAR 7-30-22 11:54PM > < I40200 OCT 13, 2022 11:34 AM >