Loading...
HomeMy WebLinkAbout002-A2.00 Demolition Floor Plan(E) DINING ROOM 03 (E) DRY STORAGE 11 (E) ENTRY 01 (E) CORRIDOR 04 (E) FOOD SERVICE 14 (E) FOOD SERVICE LINE 02 (E) STORAGE 10 (E) WOMEN 06 (E) MEN 05 (N) OPEN AIR PATIO 16 (E) KITCHEN 13 (E) BAKING 12 (E) CORRIDOR 07 (E) CORRIDOR 08 (E) CORRIDOR 09 (E) DINING PATIO 15 03 03 03 03 03 03 .04 06 06 06 06 06 06 06 06 06 02 02 02 02 02 06 05 05 05 02 03 03 03 03 0303 03 03 0303 0303 03 03 01 01 01 TYP ALL INTERIOR WALLS TYP ALL EXTERIOR WALLS EXCOLEXCOLEXCOLEXCOL EXC OL EX C OL EXCOLEXCOLEXCOLLINE OF EXISTING ROOF ABOVE LINE OF EXISTING ROOF ABOVE LINE OF EXISTING ROOF ABOVE EX EX EX EX EX 7'-2" G1± 15'-6"FIELD VERIFYG2 9'-9"6'-3"10'-5"10'-11"LINE OF EXISTING PORCH CANOPY TO REMAIN/LIMIT OF FIRE AREA LINE OF EXISTING PORCH CANOPY TO REMAIN/LIMIT OF FIRE AREA (N) OPEN AIR PATIO 17 EXISTING PORCH CANOPY COLUMN TO REMAIN, TYP. EXISTING PORCH CANOPY COLUMN TO REMAIN, TYP. 23'-4"7'-1" 12" 9'-6" 4'-4"21'-5"2'-0"RAISED PLANTER LANDSCAPE AREA12"9'-3"48'-7"± 0" FIELD VERIFY 45'-9" REFER TO PERMIT # 22-8827 FOR ACCESSIBLE RESTROOMS REFER TO PERMIT # 22-8827 FOR ACCESSIBLE RAMP VALUE ENGINEERING DESIGN CHANGE 3'-0" TALL DECORATIVE FENCE EDGE OF CONCRETE 8'-0" TALL DECORATIVE FENCE ON CURB 8'-0" TALL DECORATIVE FENCE ON CURB 8'-0" TALL DECORATIVE FENCE RAMP1:12 SLOPE+ 18" AFF EDGE OF ASPHALT 8'-0" TALL DECORATIVE FENCEDETECTABLE WARNING SURFACE3'-0"3'-0" TALL DECORATIVE FENCE EDGE OF CONCRETE EDGE OF CONCRETE LANDCSCAPE AREA LANDCSCAPE AREA EDGE OF CONCRETE ± 3'-0"F.V.RAMP HANDRAIL 55 A8.00 NEW CONCRETE EX SIDEWALK NEW DWS EX SIDEWALK 33'-6" 21'-5" 2'-2" 8'-0" TALL DECORATIVE FENCEFOW03 EX EX EX EX 7'-0"2'-0"T RE JAMES PATRICK FOGARTY F No. C-19670 ETTASOACFLIODECLINSERAIHCIANTC REN 30 11 JAMES PATRICK FOGARTY, AIA A R C H I T E C T C - 1 9 6 7 0 23 3 4 3 4 T r u x t u n Av e n u e . S u i t e 2 4 0 B a k e r s f i e l d . C a l i f o r n i a . 9 3 3 0 1 t e l| 6 6 1 . 3 2 7 . 1 6 9 0 fa x| 6 6 1 . 3 2 7 . 7 2 0 4 w e b | w w w . a p a r c h i t e c t s . n e t JAKE'S TEX MEX PATIO ADDITION PLAN CHECK PROJECT INFO REVISIONS CONSULTANT ARCHITECT No Date Item 10.19.22 09:42 THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE P RO P ERTY O F THE ADDING TO N PARTNERSHIP. ALL DESIGNS AND DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE US ED O THERWIS E WITHO UT THE EXP RES SED WR ITTE N P E R MIS S IO N O F TH E AD D IN G TO N PARTNERSHIP. WRITTEN SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FO R ALL DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. S HOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. © COPYRIGHT 08.17.2021 570-0001Project No Date 03.15.22 PLAN CHECK CORRECTIONS1 JAMES PATRICK FOGARTY, AIA A R C H I T E C T C - 1 9 6 7 0 1 7 1 0 O A K S T R E E T BAKERSFIELD, CA 93301 6 6 1 . 3 2 2 . 6 3 8 0 05.24.22 PLAN CHECK CORRECTIONS2 08.03.22 VALUE ENGINEERING3 10.19.22 PLAN CHECK CORRECTIONS4 A2.00 DEMOLITION FLOOR PLAN/ FLOOR PLAN 1. PATCH WALL AND CEILING PENETRATIONS FLUSH TO MATCH ADJACENT FINISH WHERE ITEMS INDICATED TO BE REMOVED. RATED WALLS TO BE PATCHED OR SEALED W/ MATERIALS TO MAINTAIN REQUIRED WALL RATING. SEAL EX HVAC DUCTWORK TO REMAIN IN AREA OF CONSTRUCTION PRIOR TO START OF CONSTRUCTION. 2. PATCH WALL AND CLG FINISH(ES) FLUSH TO MATCH ADJACENT FINISH WHERE EX MECH, PLBG AND ELEC ITEMS ARE INDICATED TO BE REMOVED IN EX WALLS AND CEILINGS. 3. PATCH CONC FLOOR FLUSH TO MATCH ADJACENT FINISH WHERE ITEMS INDICATED TO BE REMOVED. 4. REINSTALL EX SALVAGED FLOOR MTD DOOR STOPS AT EX DOORS TO REMAIN UNO. 5. REINSTALL EX SALVAGED DOOR THRESHOLDS AT EX DOORS TO REMAIN UNO. 6. RESEAL PERIMETER OF EX EXTERIOR DOOR AND WINDOW FRAMES W/ ES4 SEALANT. GENERAL FLOOR PLAN NOTES EXISTING EXTERIOR BUILDING WALL TO REMAIN 6" WOOD STUD WALL AT 16"OC 17-02-11 FLOOR PLAN LEGEND Line Style Description W1 W3 W4 52 A8.00 Detail FLOOR PLAN KEYNOTES EXISTING DOOR TO REMAIN EXISTING SCREEN/SHUTTER TO REMAIN EXISTING WINDOW TO REMAIN NOT USED 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 EXISTING INTERIOR WALL TO REMAIN EXISTING EXTERIOR PATIO WALL TO REMAIN (NON-FULL HEIGHT)W2 8" CMU BLOCK WALL, SEE STRUCTURALW5 EXISTING WALL TO REMAIN NOT USED NOT USED NOT USED LINE OF ROOF ABOVE, SEE STRUCTURAL FOR MORE INFORMATION LINE OF EDGE OF CONCRETE NOT USED NOT USED NOT USED NO SCOPE OF WORK THIS AREA EXISTING WINDOW TO BE REMOVED. FRAME/INFILL EXISTING OPENING FOR NEW DOOR AS REQUIRED FOR NEW DOOR FRAME, PATCH INTERIOR AND EXTERIOR FINISHES TO MATCH EXISTING ADJACENT. NEW DOOR, JAMB AND THRESHOLD EXISTING SCREEN/SHUTTER TO BE REMOVED, NEW CASED OPENING TO BE INSTALLED18 CONCRETE FLOOR SURFACE AT PATIO19 NOT USED20 EXISTING ROOF CANOPY COLUMN FENCE POST NOT USED DOOR TYPE SCHEDULE SOLID CORE WOOD DOOR TH SIZE SILL FRAME MTL TYPE HEAD FIRE RATING JAMB HDWR NO PANIC HDWR Details NO Door GATE A B DOOR SCHEDULE 3 1 GATEC EX EXISTING - - EXISTING EXISTING - - - -- - 01 3'-0"x7'-0"1-3/4" WD A WDF N/A - - - -01 - 02 - - - - 03 - - - - 04 - - - - 05 - - - - G1 - - - - G2 - - - - G3 - - - - G4 - - - - OUTSIDE LOCATION INSIDE LOCATION N/A EXTERIOR 00 SCREEN PORCH 00 SCREEN PORCH 01 ENTRY 16 DINING PATIO 03 DINING 07 CORRIDOR 05 MEN 07 CORRIDOR 06 WOMEN EXTERIOR LANDSCAPE AREA EXTERIOR OPEN AIR PATIO EXTERIOR RAMP EXTERIOR PATIO 3'-0"x7'-0"1-3/4" XWDD A XWDF N/A 04 - 3'-0"x7'-0"1-3/4" A N/A 02 -WD WDF 3'-0"x7'-0"1-3/4" A N/A 03 -WD WDF 3'-0"x7'-0"1-3/4" A N/A 03 -WD WDF 3'-0"x8-0"1-3/4"B N/A 05 -WI WIF 3'-0"x8'-0"1-3/4"B N/A 07 YWIWIF 3'-0"x7'-0"1-3/4"C N/A 06 YWIWIF 3'-0"x7'-0"1-3/4"B N/A 06 YWIWIF 3 3 3 3 3 NORTHNORTH WORKING Scale: 1/4" = 1'-0" Demolition Floor Plan/Floor Plan 3 3 3 3 3 3 3 3 35 A8.00 4 35 A8.00 4 35 A8.00 4 45 A8.00 4 45 A8.00 4 22-00010908 11/07/22 22-30000035 01/25/23