Loading...
HomeMy WebLinkAbout4013 S. H St EMC (North) 5-2-2023 (Rejected - no permit)Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10159161 5/2/2023 Jaco #7721 Fastrip #22 4013 South H St Bakersfield, Ca 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Isaias Palacios 1073967 8391568 9/29/2024 Veeder root B46565 03/22/2024 5/2/2023 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 87 STP L2 420 87 Annular L3 208 91 STP L4 420 91 Annular L5 208 DSL STP L6 420 DSL Annular L7 NA L8 NA L9 208 Dispenser 9/10 L10 208 Dispenser 11/12 L11 208 Dispenser 13/14 L12 208 Dispenser 15/16 L13 208 Dispenser 17/18 L14 208 Dispenser 19/20 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V Unleaded T2 FX1V Premium T3 FX1DV DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Performed EMC testing due to cold-start. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. F EXISTING BUILDING NOPARKING 56L11 #7-781 78L10 34L12 12L9 12,000 GALLON87-1 UNLEADED 12,000 GALLON87-2 UNLEADED 12,000 GALLONPREMIUM 12,000 GALLONDIESEL V AL2 STPL1 FV AL6 STPL5 FV AL8 STPL7 F AL4 STPL3 109L91413L121211L101615L122019L141817L1312,000 GALLON87 UNLEADED12,000 GALLONPREMIUM12,000 GALLONDIESELFAL6STPL5FVAL4STPL3FVAL2STPL1NOPARKING G W 7-721 7-781 #7-721DUMPSTER H H PRICE SIGN PRICE SIGN 40' STORAGE CONTA INER S. H ST.WHITE LN.PROPERTY LINE PROPERTY LINE N CAT C HBAS I N 721 LEGEND L1 87 STP L2 87 ANNULAR L3 91 STP L4 91 ANNULAR L5 DSL STP L6 DSL ANNULAR L9 UDC 9 - 10 L10 UDC 11 -12 L11 UDC 13 - 14 L12 UDC 15 - 16 L13 UDC 17 - 18 L14 UDC 19 - 20 781 LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 DSL STP L4 DSL ANNULAR L5 87-2 STP L6 87-2 ANNULAR L7 91 STP L8 91 ANNULAR L9 UDC 1 -2 L10 UDC 7 - 8 L11 UDC 5 -6 L12 UDC 3 - 4 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 3/2 INCH DOUBLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 3/32"=1'-0" INCHES012 SHEET SIZE 22 X 34 4013 S. H ST. BAKERSFIELD, CA 93304 PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FASTRIP #7721 FACILITY ID 15-021-100296 CERS ID 10159161 FASTRIP #7781 FACILITY ID 15-021-003022 CERS ID 10159163 4013 S. H ST. BAKERSFIELD, CA 93304 03/02/17 REV.S. H ST.WHITE LN. Jaco#7721 Cold Start Alarm History After. Responses Received: I10200 MAY 2, 2023 5:14 PM FASTRIP 4013 S H ST BAKERSFIELD SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 507550 505805 2 INTERSTITIAL BD 202297 202007 3 4 PROBE / G.T. 163116 162771 4 INTERSTITIAL BD 201119 200726 5 UNUSED 4925158 4902879 6 UNUSED 4919506 4900889 7 UNUSED 4918637 4902070 8 UNUSED 4915441 4900146 9 STP SENSE BOARD 33132 33095 10 RELAY BOARD 15000 14963 11 UNUSED 4922919 4904339 12 UNUSED 4919289 4900140 13 UNUSED 4917137 4902545 14 UNUSED 4916680 4899877 15 UNUSED 4918050 4900643 16 UNUSED 4917224 4899221 COMM 1 ELEC DISP INT. 101140 101005 COMM 2 RS232 SERIAL BD 15000 15007 COMM 3 RS232 SERIAL BD 14956 14963 COMM 4 UNUSED 4920137 4902917 COMM 5 UNUSED 4916876 4901977 COMM 6 UNUSED 4916267 4903705 I90200 MAY 2, 2023 5:14 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 MAY 2, 2023 5:14 PM FASTRIP 4013 S H ST BAKERSFIELD PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L10 DISP PAN 11-12 SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L12 DISP PAN 15-16 SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L14 DISP PAN 19-20 SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L11 DISP PAN 13-14 SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 9 DISP PAN 9-10 SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L13 DISP PAN 17-18 SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 4 ANNULAR 91 ANN SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 3 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 2 ANNULAR 87 ANN SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 6 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 1 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L 5 STP SUMP DEISE STP SENSOR OUT ALARM CLEAR 5-02-23 5:04PM L12 DISP PAN 15-16 SENSOR OUT ALARM ALARM 5-02-23 5:03PM L14 DISP PAN 19-20 SENSOR OUT ALARM ALARM 5-02-23 5:03PM L11 DISP PAN 13-14 SENSOR OUT ALARM ALARM 5-02-23 5:03PM L13 DISP PAN 17-18 SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 3 STP SUMP 91 STP SENSOR OUT ALARM ALARM 5-02-23 5:03PM L10 DISP PAN 11-12 SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 9 DISP PAN 9-10 SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 2 ANNULAR 87 ANN SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 6 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 1 STP SUMP 87 STP SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 5 STP SUMP DEISE STP SENSOR OUT ALARM ALARM 5-02-23 5:03PM L 4 ANNULAR 91 ANN SENSOR OUT ALARM ALARM 5-02-23 5:03PM L12 DISP PAN 15-16 FUEL ALARM CLEAR 5-02-23 5:01PM L12 DISP PAN 15-16 FUEL ALARM ALARM 5-02-23 5:01PM L11 DISP PAN 13-14 FUEL ALARM CLEAR 5-02-23 5:01PM L11 DISP PAN 13-14 FUEL ALARM ALARM 5-02-23 5:01PM L10 DISP PAN 11-12 FUEL ALARM CLEAR 5-02-23 5:01PM L10 DISP PAN 11-12 FUEL ALARM ALARM 5-02-23 5:01PM L 2 ANNULAR 87 ANN FUEL ALARM CLEAR 5-02-23 5:01PM L 2 ANNULAR 87 ANN FUEL ALARM ALARM 5-02-23 5:01PM L 3 STP SUMP 91 STP FUEL ALARM CLEAR 5-02-23 5:01PM L 3 STP SUMP 91 STP FUEL ALARM ALARM 5-02-23 5:01PM L 4 ANNULAR 91 ANN FUEL ALARM CLEAR 5-02-23 5:00PM L 4 ANNULAR 91 ANN FUEL ALARM ALARM 5-02-23 5:00PM L12 DISP PAN 15-16 FUEL ALARM CLEAR 5-02-23 5:00PM L12 DISP PAN 15-16 FUEL ALARM ALARM 5-02-23 5:00PM L 5 STP SUMP DEISE STP FUEL ALARM CLEAR 5-02-23 5:00PM L 5 STP SUMP DEISE STP FUEL ALARM ALARM 5-02-23 5:00PM L13 DISP PAN 17-18 FUEL ALARM CLEAR 5-02-23 5:00PM L13 DISP PAN 17-18 FUEL ALARM ALARM 5-02-23 5:00PM L 6 ANNULAR DSL ANN FUEL ALARM CLEAR 5-02-23 5:00PM L 6 ANNULAR DSL ANN FUEL ALARM ALARM 5-02-23 5:00PM L 9 DISP PAN 9-10 FUEL ALARM CLEAR 5-02-23 4:59PM L 9 DISP PAN 9-10 FUEL ALARM ALARM 5-02-23 4:59PM L 1 STP SUMP 87 STP FUEL ALARM CLEAR 5-02-23 4:59PM L 1 STP SUMP 87 STP FUEL ALARM ALARM 5-02-23 4:59PM L14 DISP PAN 19-20 FUEL ALARM CLEAR 5-02-23 4:59PM L14 DISP PAN 19-20 FUEL ALARM ALARM 5-02-23 4:59PM I11200 MAY 2, 2023 5:15 PM FASTRIP 4013 S H ST BAKERSFIELD NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME I20600 MAY 2, 2023 5:15 PM FASTRIP 4013 S H ST BAKERSFIELD TANK ALARM HISTORY TANK 1 87 TANK 2 91 TANK 3 DSL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 MAY 2, 2023 5:15 PM I30200 MAY 2, 2023 5:15 PM FASTRIP 4013 S H ST BAKERSFIELD LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 STP MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 4:59 PM FUEL ALARM 2 87 ANN MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:01 PM FUEL ALARM 3 91 STP MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:01 PM FUEL ALARM 4 91 ANN MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:00 PM FUEL ALARM 5 DEISE STP MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:00 PM FUEL ALARM 6 DSL ANN MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:00 PM FUEL ALARM 9 9-10 MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 4:59 PM FUEL ALARM 10 11-12 MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:01 PM FUEL ALARM 11 13-14 MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:01 PM FUEL ALARM 12 15-16 MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:01 PM FUEL ALARM MAY 2, 2023 5:00 PM FUEL ALARM 13 17-18 MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 5:00 PM FUEL ALARM 14 19-20 MAY 2, 2023 5:03 PM SENSOR OUT ALARM MAY 2, 2023 4:59 PM FUEL ALARM I31600 MAY 2, 2023 5:15 PM FASTRIP 4013 S H ST BAKERSFIELD SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VPS 2 FM1 3 FM2 4 FM3 5 FM4 6 FM5 7 FM6 I40200 MAY 2, 2023 5:15 PM I40300 MAY 2, 2023 5:15 PM I34200 MAY 2, 2023 5:15 PM I34700 MAY 2, 2023 5:15 PM IV0100 MAY 2, 2023 5:15 PM FASTRIP 4013 S H ST BAKERSFIELD ISD ALARM STATUS REPORT WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-04-17 00:00:45 A/L RATIO DEGRADATION FP 2 BLEND3 0.80 23-04-16 00:00:32 A/L RATIO DEGRADATION FP 2 BLEND3 0.80 23-04-14 00:00:28 A/L RATIO DEGRADATION FP 2 BLEND3 0.79 23-04-13 00:00:15 A/L RATIO DEGRADATION FP 3 BLEND3 0.55 23-04-12 00:01:12 A/L RATIO DEGRADATION FP 3 BLEND3 0.55 23-04-11 00:01:07 A/L RATIO DEGRADATION FP 3 BLEND3 0.55 23-04-03 10:01:33 A/L RATIO DEGRADATION FP 3 BLEND3 0.54 23-04-02 10:01:52 A/L RATIO DEGRADATION FP 3 BLEND3 0.76 23-04-01 10:01:38 A/L RATIO DEGRADATION FP 3 BLEND3 0.77 23-03-06 00:01:25 CONTAINMENT PRESSURE DEGRADATIONMONTHLY 75% 0.44 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-07 00:02:17 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 23-01-24 00:01:42 A/L RATIO DEGRADATION FP 2 BLEND3 0.76 23-01-23 00:01:35 A/L RATIO DEGRADATION FP 2 BLEND3 0.76 23-01-22 00:01:37 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 23-01-21 00:01:24 A/L RATIO DEGRADATION FP 2 BLEND3 0.77 23-01-20 00:01:21 A/L RATIO DEGRADATION FP 2 BLEND3 0.79 23-01-18 00:01:01 A/L RATIO DEGRADATION FP 2 BLEND3 0.77 23-01-06 00:00:49 A/L RATIO DEGRADATION FP 2 BLEND3 0.79 23-01-05 00:00:46 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 23-01-04 00:00:49 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-05-02 17:04:21 READINESS ISD:PF EVR:NNN CHECK ISD SENSORS 23-05-02 17:04:21 ISD STARTUP 23-05-02 17:04:15 ISD SHUTDOWN 23-05-02 15:15:00 TIME CHANGE DETECTED AT: 23-05-02 08:18:27 23-05-02 08:18:04 TIME CHANGE DETECTED AT: 21-02-13 08:18:03 23-04-29 00:00:28 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-04-28 00:00:45 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-04-27 00:00:59 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-04-26 00:00:48 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-04-25 00:00:50 READINESS ISD:PP EVR:NP EVR READINESS PENDING Setup Responses Received: 200 FASTRIP 4013 S H ST BAKERSFIELD MAY 2, 2023 5:15 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 87 8105 61.40 0.0 65.6 3895 2 91 10498 78.45 0.0 69.9 1502 3 DSL 1988 21.35 0.0 73.4 10012 I90500 MAY 2, 2023 5:16 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 MAY 2, 2023 5:16 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 MAY 2, 2023 5:16 PM SHIFT TIME 1 : 6:00 AM I50202 MAY 2, 2023 5:16 PM SHIFT TIME 2 : DISABLED I50203 MAY 2, 2023 5:16 PM SHIFT TIME 3 : DISABLED I50204 MAY 2, 2023 5:16 PM SHIFT TIME 4 : DISABLED I54600 MAY 2, 2023 5:16 PM TANK PER TST NEEDED WRN: DISABLED I54900 MAY 2, 2023 5:16 PM TANK ANN TST NEEDED WRN: DISABLED I55300 MAY 2, 2023 5:16 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 MAY 2, 2023 5:16 PM LINE PER TST NEEDED WRN: DISABLED I55900 MAY 2, 2023 5:16 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 MAY 2, 2023 5:16 PM PRINT TC VOLUMES ENABLED I50E00 MAY 2, 2023 5:16 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 MAY 2, 2023 5:16 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 MAY 2, 2023 5:16 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 MAY 2, 2023 5:16 PM DAYLIGHT SAVING TIME DISABLED I51B00 MAY 2, 2023 5:16 PM I51600 MAY 2, 2023 5:16 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 MAY 2, 2023 5:16 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 MAY 2, 2023 5:16 PM TANK CHART SECURITY DISABLED I5BD00 MAY 2, 2023 5:16 PM CUSTOM ALARM LABELS DISABLED I56000 MAY 2, 2023 5:16 PM MASS/DENSITY DISABLED I88101 MAY 2, 2023 5:16 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 MAY 2, 2023 5:16 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 MAY 2, 2023 5:16 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88104 MAY 2, 2023 5:16 PM I88105 MAY 2, 2023 5:16 PM I88106 MAY 2, 2023 5:16 PM I52000 MAY 2, 2023 5:16 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUN 30, 2022 DISABLED 2 ON DATE JUN 30, 2022 DISABLED 3 ON DATE JUN 30, 2022 DISABLED 4 ON DATE JUN 30, 2022 DISABLED 5 ON DATE JUN 30, 2022 DISABLED 6 ON DATE JUN 30, 2022 DISABLED 7 ON DATE JUN 30, 2022 DISABLED 8 ON DATE JUN 30, 2022 DISABLED I60100 MAY 2, 2023 5:16 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 87 ON 2 91 ON 3 DSL ON 4 OFF I60200 MAY 2, 2023 5:16 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 87 2 91 3 DSL 4 I60300 MAY 2, 2023 5:16 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 87 1 2 91 2 3 DSL 3 4 4 I60900 MAY 2, 2023 5:16 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 87 0.000700 2 91 0.000700 3 DSL 0.000450 4 0.000000 I60700 MAY 2, 2023 5:16 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 87 96.00 2 91 96.00 3 DSL 96.00 4 0.00 I60A00 MAY 2, 2023 5:16 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 87 1 PT 12000 2 91 1 PT 12000 3 DSL 1 PT 12000 4 1 PT 0 I60400 MAY 2, 2023 5:16 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 87 12000 2 91 12000 3 DSL 12000 4 0 I60500 MAY 2, 2023 5:16 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 12000 0 0 0 2 91 12000 0 0 0 3 DSL 12000 0 0 0 4 0 0 0 0 I60600 MAY 2, 2023 5:16 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 91 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DSL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 MAY 2, 2023 5:16 PM TANK PRODUCT LABEL METER DATA 1 87 NO 2 91 NO 3 DSL NO 4 NO I62F00 MAY 2, 2023 5:16 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 87 4.0 IN. 2 91 4.0 IN. 3 DSL 4.0 IN. I62700 MAY 2, 2023 5:16 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 87 2.0 2 91 2.0 3 DSL 2.0 I64200 MAY 2, 2023 5:16 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 87 LOW 2 91 LOW 3 DSL LOW I62400 MAY 2, 2023 5:16 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 87 3.0 2 91 3.0 3 DSL 3.0 I62800 MAY 2, 2023 5:16 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 87 12000 2 91 12000 3 DSL 12000 4 0 I62300 MAY 2, 2023 5:16 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 87 10800 2 91 10800 3 DSL 10800 4 0 I62200 MAY 2, 2023 5:16 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 11400 2 91 11400 3 DSL 11400 4 0 I62900 MAY 2, 2023 5:16 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 87 1200 2 91 1200 3 DSL 1200 4 0 I62100 MAY 2, 2023 5:16 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 1200 2 91 1200 3 DSL 1200 4 0 I62600 MAY 2, 2023 5:16 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 99 2 91 99 3 DSL 99 4 99 I62500 MAY 2, 2023 5:16 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 87 99 2 91 99 3 DSL 99 4 99 I60800 MAY 2, 2023 5:16 PM TANK TILT TANK PRODUCT LABEL INCHES 1 87 0.00 2 91 0.00 3 DSL 0.00 4 0.00 I60B00 MAY 2, 2023 5:16 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 MAY 2, 2023 5:16 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 87 0.00 2 91 0.00 3 DSL 0.00 4 0.00 I61200 MAY 2, 2023 5:16 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 87 NONE NONE 2 91 NONE NONE 3 DSL NONE NONE 4 NONE NONE I63600 MAY 2, 2023 5:16 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 120 2 91 120 3 DSL 120 4 0 I62A00 MAY 2, 2023 5:16 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 120 2 91 120 3 DSL 120 4 0 I62C00 MAY 2, 2023 5:16 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 87 STANDARD 2 91 STANDARD 3 DSL STANDARD 4 STANDARD I62D00 MAY 2, 2023 5:16 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 87 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 91 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DSL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 MAY 2, 2023 5:16 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 87 OFF OFF 2 91 OFF OFF 3 DSL OFF OFF 4 OFF OFF I63000 MAY 2, 2023 5:16 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 87 OFF 2 91 OFF 3 DSL OFF 4 OFF I63200 MAY 2, 2023 5:16 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 87 OFF 2 91 OFF 3 DSL OFF 4 OFF I61000 MAY 2, 2023 5:16 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 87 1 2 91 1 3 DSL 1 4 1 I63A00 MAY 2, 2023 5:16 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 87 10.00% 2 91 10.00% 3 DSL 10.00% 4 10.00% I61100 MAY 2, 2023 5:16 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK FEB 13, 2021 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 MAY 2, 2023 5:16 PM CSLD PROBABLITY OF DETECTION I61400 MAY 2, 2023 5:16 PM CSLD CLIMATE FACTOR I61600 MAY 2, 2023 5:16 PM TANK PRODUCT LABEL CAL UPDATE 1 87 IMMEDIATE 2 91 IMMEDIATE 3 DSL IMMEDIATE 4 IMMEDIATE I61A00 MAY 2, 2023 5:16 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 87 DISABLED 2 91 DISABLED 3 DSL DISABLED 4 DISABLED I61B00 MAY 2, 2023 5:16 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 MAY 2, 2023 5:16 PM CSLD REPORT ONLY I62B00 MAY 2, 2023 5:16 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 87 ??? 0, 0 2 91 ??? 0, 0 3 DSL ??? 0, 0 4 ??? 0, 0 I63300 MAY 2, 2023 5:16 PM LEAK TEST REPORT FORMAT: NORMAL I63400 MAY 2, 2023 5:16 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 87 0 2 91 0 3 DSL 0 4 0 I63500 MAY 2, 2023 5:16 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 1 2 91 1 3 DSL 1 4 1 I63900 MAY 2, 2023 5:16 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 87 END FACTOR: NONE 2 91 END FACTOR: NONE 3 DSL END FACTOR: NONE 4 END FACTOR: NONE I78000 MAY 2, 2023 5:16 PM I77700 MAY 2, 2023 5:16 PM I77800 MAY 2, 2023 5:16 PM I78C00 MAY 2, 2023 5:16 PM I78300 MAY 2, 2023 5:16 PM I78F00 MAY 2, 2023 5:16 PM I78700 MAY 2, 2023 5:16 PM I70200 MAY 2, 2023 5:16 PM LIQUID LABEL DEVICE LABEL 1 87 STP 2 87 ANN 3 91 STP 4 91 ANN 5 DEISE STP 6 DSL ANN 7 8 9 9-10 10 11-12 11 13-14 12 15-16 13 17-18 14 19-20 15 16 I70300 MAY 2, 2023 5:16 PM LIQUID TYPE SENSOR LOCATION TYPE 1 87 STP TRI-STATE (SINGLE FLOAT) 2 87 ANN TRI-STATE (SINGLE FLOAT) 3 91 STP TRI-STATE (SINGLE FLOAT) 4 91 ANN TRI-STATE (SINGLE FLOAT) 5 DEISE STP TRI-STATE (SINGLE FLOAT) 6 DSL ANN TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 9-10 TRI-STATE (SINGLE FLOAT) 10 11-12 TRI-STATE (SINGLE FLOAT) 11 13-14 TRI-STATE (SINGLE FLOAT) 12 15-16 TRI-STATE (SINGLE FLOAT) 13 17-18 TRI-STATE (SINGLE FLOAT) 14 19-20 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 MAY 2, 2023 5:16 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87 STP STP SUMP 2 87 ANN ANNULAR SPACE 3 91 STP STP SUMP 4 91 ANN ANNULAR SPACE 5 DEISE STP STP SUMP 6 DSL ANN ANNULAR SPACE 7 OTHER SENSORS 8 OTHER SENSORS 9 9-10 DISPENSER PAN 10 11-12 DISPENSER PAN 11 13-14 DISPENSER PAN 12 15-16 DISPENSER PAN 13 17-18 DISPENSER PAN 14 19-20 DISPENSER PAN 15 OTHER SENSORS 16 OTHER SENSORS I74200 MAY 2, 2023 5:16 PM I74300 MAY 2, 2023 5:16 PM I74400 MAY 2, 2023 5:16 PM I74700 MAY 2, 2023 5:16 PM I74800 MAY 2, 2023 5:16 PM I74900 MAY 2, 2023 5:16 PM I7BC00 MAY 2, 2023 5:16 PM I80200 MAY 2, 2023 5:16 PM I80300 MAY 2, 2023 5:16 PM I80400 MAY 2, 2023 5:17 PM I80700 MAY 2, 2023 5:17 PM RELAY LABEL DEVICE LABEL 1 87 2 91 3 DSL 4 OVERFILL I80900 MAY 2, 2023 5:17 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 NORMALLY OPEN 2 91 NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 OVERFILL NORMALLY OPEN I80B00 MAY 2, 2023 5:17 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 1 2 91 2 3 DSL NONE 4 OVERFILL 4 I80A00 MAY 2, 2023 5:17 PM RELAY TYPE RELAY DESIGNATION TYPE 1 87 PUMP CONTROL OUTPUT 2 91 PUMP CONTROL OUTPUT 3 DSL STANDARD 4 OVERFILL STANDARD I80C00 MAY 2, 2023 5:17 PM I80800 MAY 2, 2023 5:17 PM RELAY SETUP REPORT R 1:87 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 1:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L14:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 2:91 TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 1:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM R 4:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: 4 IN-TANK ALARMS ALL:LEAK ALARM ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM I79000 MAY 2, 2023 5:17 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 MAY 2, 2023 5:17 PM I72300 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 VPS VAPOR PRESSURE 02 FM1 AIR FLOW METER 03 FM2 AIR FLOW METER 04 FM3 AIR FLOW METER 05 FM4 AIR FLOW METER 06 FM5 AIR FLOW METER 07 FM6 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: VAPOR VAC IV4F00 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD VAPOR PROCESSOR TYPE NONE IV4700 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD ASSESSMENT TIME START TIME: 11:59 PM TIME DELAY MINUTES: 1 IV5200 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD ACCEPT HIGH ORVR: NO IV4A00 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 09 01 02 BLEND3 02 02 10 01 02 BLEND3 03 03 11 02 02 BLEND3 04 04 12 02 02 BLEND3 05 05 13 03 02 BLEND3 06 06 14 03 02 BLEND3 07 07 15 04 02 BLEND3 08 08 16 04 02 BLEND3 09 09 17 05 02 BLEND3 10 10 18 05 02 BLEND3 11 11 19 06 02 BLEND3 12 12 20 06 02 BLEND3 IV4B00 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx 09 05 02/09 03/09 09/09 xx/xx 10 05 02/10 03/10 09/10 xx/xx 11 06 03/11 09/11 02/11 xx/xx 12 06 02/12 03/12 09/12 xx/xx IV4900 MAY 2, 2023 5:17 PM FASTRIP 4013 S H ST BAKERSFIELD LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 MAY 2, 2023 5:17 PM ISD VERSION: 01.07