Loading...
HomeMy WebLinkAbout4013 S. H St EMC (South) 4-6-2023 (Rejected - no permit)Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10159161 4/6/2023 Jaco #7781 Fastrip #22 4013 South H St Bakersfield, Ca 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Jason Woods 1073967 8492093 03/1/2025 Veeder root C26937 07/26/2023 4/6/2023 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 87 1 STP L2 NA L3 208 DSL STP L4 420 DSL Annular L5 208 87-2 STP L6 420 87-2 Annular L7 208 91 STP L8 420 91 Annular L9 208 Dispenser 1/2 L10 208 Dispenser 7/8 L11 208 Dispenser 5/6 L12 208 Dispenser 3/4 L13 208 87 Annular Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V Unleaded T2 FX1V Premium T3 FX1DV DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Performed EMC due to software upgrade. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. F EXISTING BUILDING NOPARKING 56L11 #7-781 78L10 34L12 12L9 12,000 GALLON87-1 UNLEADED 12,000 GALLON87-2 UNLEADED 12,000 GALLONPREMIUM 12,000 GALLONDIESEL V AL2 STPL1 FV AL6 STPL5 FV AL8 STPL7 F AL4 STPL3 109L91413L121211L101615L122019L141817L1312,000 GALLON87 UNLEADED12,000 GALLONPREMIUM12,000 GALLONDIESELFAL6STPL5FVAL4STPL3FVAL2STPL1NOPARKING G W 7-721 7-781 #7-721DUMPSTER H H PRICE SIGN PRICE SIGN 40' STORAGE CONTA INER S. H ST.WHITE LN.PROPERTY LINE PROPERTY LINE N CAT C HBAS I N 721 LEGEND L1 87 STP L2 87 ANNULAR L3 91 STP L4 91 ANNULAR L5 DSL STP L6 DSL ANNULAR L9 UDC 9 - 10 L10 UDC 11 -12 L11 UDC 13 - 14 L12 UDC 15 - 16 L13 UDC 17 - 18 L14 UDC 19 - 20 781 LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 DSL STP L4 DSL ANNULAR L5 87-2 STP L6 87-2 ANNULAR L7 91 STP L8 91 ANNULAR L9 UDC 1 -2 L10 UDC 7 - 8 L11 UDC 5 -6 L12 UDC 3 - 4 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 3/2 INCH DOUBLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 3/32"=1'-0" INCHES012 SHEET SIZE 22 X 34 4013 S. H ST. BAKERSFIELD, CA 93304 PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FASTRIP #7721 FACILITY ID 15-021-100296 CERS ID 10159161 FASTRIP #7781 FACILITY ID 15-021-003022 CERS ID 10159163 4013 S. H ST. BAKERSFIELD, CA 93304 03/02/17 REV.S. H ST.WHITE LN. Jaco#7781 Setup and Alarm History Before. Setup. Responses Received: 200 FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 APR 6, 2023 11:15 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 7745 68.30 0.8 57.4 4317 2 UNL 2 8493 73.95 0.9 58.5 3569 3 PNL 4163 42.05 0.8 63.4 7899 4 DIESEL 2957 32.76 0.0 66.6 9105 I90500 APR 6, 2023 11:15 AM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 APR 6, 2023 11:15 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 APR 6, 2023 11:15 AM SHIFT TIME 1 : 6:00 AM I50202 APR 6, 2023 11:15 AM SHIFT TIME 2 : DISABLED I50203 APR 6, 2023 11:15 AM SHIFT TIME 3 : DISABLED I50204 APR 6, 2023 11:15 AM SHIFT TIME 4 : DISABLED I54600 APR 6, 2023 11:15 AM TANK PER TST NEEDED WRN: DISABLED I54900 APR 6, 2023 11:15 AM TANK ANN TST NEEDED WRN: DISABLED I55300 APR 6, 2023 11:15 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 APR 6, 2023 11:15 AM LINE PER TST NEEDED WRN: DISABLED I55900 APR 6, 2023 11:15 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 APR 6, 2023 11:15 AM PRINT TC VOLUMES ENABLED I50E00 APR 6, 2023 11:15 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 APR 6, 2023 11:15 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 APR 6, 2023 11:15 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 APR 6, 2023 11:15 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 APR 6, 2023 11:15 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 APR 6, 2023 11:15 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 APR 6, 2023 11:15 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 APR 6, 2023 11:15 AM TANK CHART SECURITY DISABLED I5BD00 APR 6, 2023 11:15 AM CUSTOM ALARM LABELS DISABLED I56000 APR 6, 2023 11:15 AM MASS/DENSITY DISABLED I88101 APR 6, 2023 11:15 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 APR 6, 2023 11:15 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 APR 6, 2023 11:15 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 APR 6, 2023 11:15 AM I88105 APR 6, 2023 11:15 AM I88106 APR 6, 2023 11:15 AM I52000 APR 6, 2023 11:15 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUL 11, 2017 DISABLED 2 ON DATE JUL 11, 2017 DISABLED 3 ON DATE JUL 11, 2017 DISABLED 4 ON DATE JUL 11, 2017 DISABLED 5 ON DATE JUL 11, 2017 DISABLED 6 ON DATE JUL 11, 2017 DISABLED 7 ON DATE JUL 11, 2017 DISABLED 8 ON DATE JUL 11, 2017 DISABLED I60100 APR 6, 2023 11:15 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 UNL 2 ON 3 PNL ON 4 DIESEL ON I60200 APR 6, 2023 11:15 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 UNL 2 3 PNL 4 DIESEL I60300 APR 6, 2023 11:15 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 2 3 PNL 3 4 DIESEL 4 I60900 APR 6, 2023 11:15 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 UNL 2 0.000700 3 PNL 0.000700 4 DIESEL 0.000450 I60700 APR 6, 2023 11:15 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 111.50 2 UNL 2 111.50 3 PNL 111.50 4 DIESEL 111.50 I60A00 APR 6, 2023 11:15 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12062 2 UNL 2 1 PT 12062 3 PNL 1 PT 12062 4 DIESEL 1 PT 12062 I60400 APR 6, 2023 11:15 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I60500 APR 6, 2023 11:15 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 2 UNL 2 12062 0 0 0 3 PNL 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 APR 6, 2023 11:15 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 APR 6, 2023 11:15 AM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 UNL 2 NO 3 PNL NO 4 DIESEL NO I62F00 APR 6, 2023 11:15 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 3.0 IN. 2 UNL 2 3.0 IN. 3 PNL 4.0 IN. 4 DIESEL 4.0 IN. I62700 APR 6, 2023 11:15 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 UNL 2 2.0 3 PNL 2.0 4 DIESEL 2.0 I64200 APR 6, 2023 11:15 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 UNL 2 LOW 3 PNL LOW 4 DIESEL LOW I62400 APR 6, 2023 11:15 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 UNL 2 3.0 3 PNL 3.0 4 DIESEL 3.0 I62800 APR 6, 2023 11:15 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I62300 APR 6, 2023 11:15 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10856 2 UNL 2 10856 3 PNL 10856 4 DIESEL 10856 I62200 APR 6, 2023 11:15 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11459 2 UNL 2 11459 3 PNL 11459 4 DIESEL 11459 I62900 APR 6, 2023 11:15 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1809 2 UNL 2 1809 3 PNL 1809 4 DIESEL 1809 I62100 APR 6, 2023 11:15 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 500 2 UNL 2 500 3 PNL 500 4 DIESEL 500 I62600 APR 6, 2023 11:15 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I62500 APR 6, 2023 11:15 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 150 3 PNL 99 4 DIESEL 99 I60800 APR 6, 2023 11:15 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 2.00 2 UNL 2 2.00 3 PNL 0.00 4 DIESEL 0.00 I60B00 APR 6, 2023 11:15 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 APR 6, 2023 11:15 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 UNL 2 0.00 3 PNL 0.00 4 DIESEL 0.00 I61200 APR 6, 2023 11:15 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 NONE NONE 2 UNL 2 NONE NONE 3 PNL NONE NONE 4 DIESEL NONE NONE I63600 APR 6, 2023 11:15 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62A00 APR 6, 2023 11:16 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62C00 APR 6, 2023 11:16 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 UNL 2 STANDARD 3 PNL STANDARD 4 DIESEL STANDARD I62D00 APR 6, 2023 11:16 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 APR 6, 2023 11:16 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 UNL 2 OFF OFF 3 PNL OFF OFF 4 DIESEL OFF OFF I63000 APR 6, 2023 11:16 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I63200 APR 6, 2023 11:16 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I61000 APR 6, 2023 11:16 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63A00 APR 6, 2023 11:16 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 UNL 2 10.00% 3 PNL 10.00% 4 DIESEL 10.00% I61100 APR 6, 2023 11:16 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 16, 2006 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 APR 6, 2023 11:16 AM CSLD PROBABLITY OF DETECTION I61400 APR 6, 2023 11:16 AM CSLD CLIMATE FACTOR I61600 APR 6, 2023 11:16 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 UNL 2 IMMEDIATE 3 PNL IMMEDIATE 4 DIESEL IMMEDIATE I61A00 APR 6, 2023 11:16 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 UNL 2 DISABLED 3 PNL DISABLED 4 DIESEL DISABLED I61B00 APR 6, 2023 11:16 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 APR 6, 2023 11:16 AM CSLD REPORT ONLY I62B00 APR 6, 2023 11:16 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 UNL 2 ??? 0, 0 3 PNL ??? 0, 0 4 DIESEL ??? 0, 0 I63300 APR 6, 2023 11:16 AM LEAK TEST REPORT FORMAT: NORMAL I63400 APR 6, 2023 11:16 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 UNL 2 0 3 PNL 0 4 DIESEL 0 I63500 APR 6, 2023 11:16 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63900 APR 6, 2023 11:16 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 UNL 2 END FACTOR: NONE 3 PNL END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 APR 6, 2023 11:16 AM I77700 APR 6, 2023 11:16 AM I77800 APR 6, 2023 11:16 AM I78C00 APR 6, 2023 11:16 AM I78300 APR 6, 2023 11:16 AM I78F00 APR 6, 2023 11:16 AM I78700 APR 6, 2023 11:16 AM I70200 APR 6, 2023 11:16 AM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DIESEL STP 4 DIESEL ANN 5 REG2 STP 6 REG 2 ANN 7 SUPER STP 8 SUPER ANN 9 DISP 1-2 10 DISP 7-8 11 DISP 5-6 12 DISP 3-4 13 T1 87 ANN 14 SO.TRANS 15 16 I70300 APR 6, 2023 11:16 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 REG2 STP TRI-STATE (SINGLE FLOAT) 6 REG 2 ANN TRI-STATE (SINGLE FLOAT) 7 SUPER STP TRI-STATE (SINGLE FLOAT) 8 SUPER ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 7-8 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 T1 87 ANN TRI-STATE (SINGLE FLOAT) 14 SO.TRANS TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 APR 6, 2023 11:16 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN OTHER SENSORS 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 REG2 STP STP SUMP 6 REG 2 ANN ANNULAR SPACE 7 SUPER STP STP SUMP 8 SUPER ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 7-8 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 T1 87 ANN ANNULAR SPACE 14 SO.TRANS OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 APR 6, 2023 11:16 AM I74300 APR 6, 2023 11:16 AM I74400 APR 6, 2023 11:16 AM I74700 APR 6, 2023 11:16 AM I74800 APR 6, 2023 11:16 AM I74900 APR 6, 2023 11:16 AM I7BC00 APR 6, 2023 11:16 AM I80200 APR 6, 2023 11:16 AM I80300 APR 6, 2023 11:16 AM I80400 APR 6, 2023 11:16 AM I80700 APR 6, 2023 11:16 AM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DIESEL 4 OVERFILL ALARM I80900 APR 6, 2023 11:16 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 APR 6, 2023 11:16 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DIESEL 4 4 OVERFILL ALARM NONE I80A00 APR 6, 2023 11:16 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 APR 6, 2023 11:16 AM I80800 APR 6, 2023 11:16 AM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 3:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 APR 6, 2023 11:17 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 APR 6, 2023 11:17 AM I72300 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNKNOWN 02 F.M DISP 1-2 AIR FLOW METER 03 F.M DISP 3-4 AIR FLOW METER 04 F.M DISP 5-6 AIR FLOW METER 05 F.M DISP 7-8 AIR FLOW METER 06 V.P. 1-2 VAPOR PRESSURE 07 UNKNOWN 08 VP 1-2 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 VAPOR PROCESSOR TYPE NONE IV4700 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ACCEPT HIGH ORVR: YES IV4A00 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 APR 6, 2023 11:17 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 APR 6, 2023 11:17 AM ISD VERSION: 01.04 Alarm History Before. Responses Received: I10200 APR 6, 2023 11:18 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39567 39731 2 4 PROBE / G.T. 163872 164447 3 INTERSTITIAL BD 202649 203290 4 INTERSTITIAL BD 201635 202503 5 UNUSED 4934902 4996276 6 UNUSED 4932969 4992730 7 UNUSED 4931930 4989890 8 UNUSED 4928169 4992253 9 STP SENSE BOARD 33228 33304 10 UNUSED 4931290 4995266 11 RELAY BOARD 14993 15007 12 UNUSED 4931830 4994001 13 UNUSED 4931186 4982764 14 UNUSED 4932204 4990995 15 UNUSED 4932536 4989108 16 UNUSED 4932038 4989377 COMM 1 RS232 SERIAL BD 15014 15070 COMM 2 RS232 SERIAL BD 15035 15070 COMM 3 ELEC DISP INT. 101769 101948 COMM 4 UNUSED 4931456 4989149 COMM 5 UNUSED 4928692 4990850 COMM 6 UNUSED 4926843 4989357 I90200 APR 6, 2023 11:18 AM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 APR 6, 2023 11:18 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNL 1 SUDDEN LOSS ALARM CLEAR 4-06-23 3:09AM T 1 TANK UNL 1 SUDDEN LOSS ALARM ALARM 4-06-23 3:05AM T 1 TANK UNL 1 SUDDEN LOSS ALARM CLEAR 4-06-23 2:45AM T 1 TANK UNL 1 SUDDEN LOSS ALARM ALARM 4-06-23 2:24AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 3-15-23 1:01PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 3-15-23 6:42AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 2-27-23 8:00AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 2-26-23 6:50PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 2-25-23 11:05AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 2-24-23 10:31PM T 2 TANK UNL 2 OVERFILL ALARM CLEAR 2-08-23 12:41AM T 2 TANK UNL 2 OVERFILL ALARM ALARM 2-08-23 12:36AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 1-17-23 7:55AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 1-16-23 7:16PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 1-10-23 7:49AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 1-09-23 7:11PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 1-02-23 11:08AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 12-31-22 7:14PM T 2 TANK UNL 2 OVERFILL ALARM CLEAR 12-29-22 12:40PM T 2 TANK UNL 2 OVERFILL ALARM ALARM 12-29-22 12:36PM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 11-22-22 5:27PM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 11-22-22 5:22PM s 5 OTHER F.M DISP 7-8 COMMUNICATION ALARM CLEAR 11-22-22 10:58AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 11-22-22 10:47AM s 5 OTHER F.M DISP 7-8 COMMUNICATION ALARM ALARM 11-22-22 8:52AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 11-22-22 8:50AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 11-22-22 8:50AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 11-22-22 8:50AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 11-22-22 8:50AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 11-22-22 8:47AM T 2 TANK UNL 2 OVERFILL ALARM CLEAR 11-09-22 7:36AM T 2 TANK UNL 2 OVERFILL ALARM ALARM 11-09-22 7:34AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 10-11-22 11:57AM s 5 OTHER F.M DISP 7-8 COMMUNICATION ALARM CLEAR 10-11-22 11:57AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 10-11-22 10:41AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 10-11-22 10:41AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 10-11-22 10:38AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 10-11-22 10:38AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 10-11-22 10:38AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 10-11-22 10:38AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 10-11-22 10:36AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 10-11-22 10:36AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 10-11-22 10:34AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 10-11-22 10:34AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 10-11-22 10:31AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 10-11-22 10:31AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 10-11-22 10:31AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 10-11-22 10:31AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 10-11-22 10:29AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 10-11-22 10:29AM I11200 APR 6, 2023 11:18 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 4-03-23 8:27PM SYSTEM PRINTER ERROR ALARM 4-03-23 8:27PM SYSTEM PRINTER ERROR CLEAR 4-03-23 8:27PM SYSTEM PRINTER ERROR ALARM 4-03-23 8:26PM SYSTEM PRINTER ERROR CLEAR 4-03-23 8:26PM SYSTEM PAPER OUT CLEAR 4-03-23 8:26PM SYSTEM PRINTER ERROR ALARM 4-03-23 8:26PM SYSTEM PAPER OUT ALARM 4-03-23 8:26PM OTHER ISD VAPOR LEAK WARN CLEAR 3-30-23 5:44PM OTHER ISD VAPOR LEAK WARN ALARM 3-22-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 3-04-23 2:23PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 3-04-23 12:19PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 3-03-23 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 3-02-23 10:02AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 2-28-23 10:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 2-27-23 10:02AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 2-13-23 1:32AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 2-12-23 10:34PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 2-03-23 3:56PM h 5 OTHER FP5: BLEND3 GROSS COLLECT WARN CLEAR 2-03-23 3:56PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 2-03-23 10:03AM h 5 OTHER FP5: BLEND3 GROSS COLLECT WARN ALARM 2-03-23 10:03AM SYSTEM PRINTER ERROR CLEAR 1-20-23 3:31PM SYSTEM PRINTER ERROR ALARM 1-20-23 3:31PM SYSTEM PRINTER ERROR CLEAR 1-20-23 3:31PM SYSTEM PAPER OUT CLEAR 1-20-23 3:31PM SYSTEM PRINTER ERROR ALARM 1-20-23 3:31PM SYSTEM PAPER OUT ALARM 1-20-23 3:31PM OTHER ISD GROSS PRES WARN CLEAR 1-04-23 10:03AM OTHER ISD GROSS PRES WARN ALARM 1-04-23 10:02AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 12-19-22 11:36AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 12-18-22 10:46PM OTHER ISD SENSOR OUT WARN CLEAR 11-22-22 5:38PM OTHER ISD SENSOR OUT WARN ALARM 11-22-22 10:02AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 11-13-22 6:24PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 11-13-22 2:22PM OTHER ISD GROSS PRES WARN CLEAR 11-08-22 3:57PM OTHER ISD GROSS PRES WARN ALARM 11-08-22 10:03AM OTHER ISD GROSS PRES WARN CLEAR 11-01-22 11:49AM OTHER ISD GROSS PRES WARN ALARM 11-01-22 10:03AM OTHER ISD GROSS PRES WARN CLEAR 10-25-22 9:21PM OTHER ISD GROSS PRES WARN ALARM 10-25-22 10:03AM OTHER ISD GROSS PRES WARN CLEAR 10-18-22 10:12AM OTHER ISD GROSS PRES WARN ALARM 10-18-22 10:02AM OTHER ISD SENSOR OUT WARN CLEAR 10-11-22 1:38PM OTHER ISD GROSS PRES WARN CLEAR 10-11-22 1:38PM SYSTEM PRINTER ERROR CLEAR 10-11-22 1:09PM SYSTEM PAPER OUT CLEAR 10-11-22 1:09PM SYSTEM PRINTER ERROR ALARM 10-11-22 10:25AM SYSTEM PAPER OUT ALARM 10-11-22 10:25AM I20600 APR 6, 2023 11:18 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM SEP 12, 2022 6:59 AM AUG 11, 2022 5:22 AM MAY 14, 2022 1:03 AM SUDDEN LOSS ALARM APR 6, 2023 3:05 AM APR 6, 2023 2:24 AM OCT 7, 2022 2:00 AM HIGH PRODUCT ALARM OCT 22, 2021 7:14 PM DELIVERY NEEDED MAR 4, 2023 12:19 PM FEB 12, 2023 10:34 PM DEC 18, 2022 10:46 PM TANK 2 UNL 2 OVERFILL ALARM FEB 8, 2023 12:36 AM DEC 29, 2022 12:36 PM NOV 9, 2022 7:34 AM HIGH PRODUCT ALARM OCT 22, 2021 7:14 PM TANK 3 PNL HIGH PRODUCT ALARM OCT 22, 2021 7:14 PM DELIVERY NEEDED SEP 17, 2022 3:07 PM TANK 4 DIESEL HIGH PRODUCT ALARM OCT 22, 2021 7:14 PM DELIVERY NEEDED NOV 13, 2022 2:22 PM SEP 6, 2022 8:21 AM AUG 23, 2022 7:23 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 6, 2023 11:19 AM I30200 APR 6, 2023 11:19 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP MAR 15, 2023 6:42 AM FUEL ALARM FEB 24, 2023 10:31 PM FUEL ALARM JAN 16, 2023 7:16 PM FUEL ALARM 3 DIESEL STP JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:39 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 4 DIESEL ANN JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:44 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 5 REG2 STP JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:37 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 6 REG 2 ANN JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:43 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 7 SUPER STP JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:39 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 8 SUPER ANN JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:44 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 9 DISP 1-2 JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:41 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 10 DISP 7-8 NOV 22, 2022 5:22 PM FUEL ALARM NOV 22, 2022 8:50 AM SENSOR OUT ALARM NOV 22, 2022 8:50 AM FUEL ALARM 11 DISP 5-6 FEB 26, 2023 6:50 PM FUEL ALARM JAN 9, 2023 7:11 PM FUEL ALARM JUL 25, 2022 9:47 AM SENSOR OUT ALARM 12 DISP 3-4 JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:41 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM 13 T1 87 ANN JUL 25, 2022 9:47 AM SENSOR OUT ALARM JUL 25, 2022 9:43 AM FUEL ALARM JUL 14, 2022 5:24 PM SENSOR OUT ALARM I31600 APR 6, 2023 11:19 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 NOV 22, 2022 8:52 AM COMMUNICATION ALARM OCT 11, 2022 9:51 AM COMMUNICATION ALARM 8 VP 1-2 I40200 APR 6, 2023 11:19 AM I40300 APR 6, 2023 11:19 AM I34200 APR 6, 2023 11:19 AM I34700 APR 6, 2023 11:19 AM IV0100 APR 6, 2023 11:19 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-28 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.30 23-03-27 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.44 23-03-25 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.93 23-03-22 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 16.80 23-03-02 10:02:40 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-02-27 10:02:41 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-02-03 10:03:33 A/L RATIO DEGRADATION FP 5 BLEND3 BLKD 23-02-03 10:03:33 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-01-04 10:02:06 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.31 22-11-22 10:02:28 SENSOR OUT SELFTEST s 5 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-05-25 10:02:51 A/L RATIO DEGRADATION FP 5 BLEND3 0.70 22-04-30 10:02:15 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-03-30 17:44:48 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 23-03-12 03:00:00 TIME CHANGE DETECTED AT: 23-03-12 02:00:13 23-02-17 10:02:17 READINESS ISD:PP EVR:PP ISD & EVR READY 23-02-16 10:02:25 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-02-15 10:02:36 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-02-15 09:49:53 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-02-15 09:49:53 ISD STARTUP 23-02-15 09:46:39 ISD SHUTDOWN 23-02-14 10:02:49 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-02-13 10:03:07 READINESS ISD:PP EVR:NP EVR READINESS PENDING ISD Setup < IV4200 APR 6, 2023 11:23 AM Sensor / Airflow Meter / Hose Table / Grade Table Relationship SS AA F1 FL M1H1L1 M2H2L2 M3H3L3 M4H4L4 F2 L2 M1H1L1 M2H2L2 M3H3L3 M4H4L4 02 01 02 01 030102 040102 100102 000000 03 02 030202 040202 100202 000000 03 02 04 03 030302 040302 100302 060000 05 04 030402 040402 100402 060000 04 03 06 05 030502 040502 100502 000000 07 06 030602 040602 100602 000000 05 04 08 07 030702 040702 100702 060000 09 08 030802 040802 100802 060000 > Jaco#7781 Setup, and Alarm History After Setup. Responses Received: 200 FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 APR 6, 2023 12:18 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 7746 68.31 0.8 57.5 4316 2 UNL 2 8493 73.95 0.9 58.5 3569 3 PNL 4163 42.05 0.8 63.4 7899 4 DIESEL 2957 32.76 0.0 66.6 9105 I90500 APR 6, 2023 12:18 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 APR 6, 2023 12:18 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 APR 6, 2023 12:18 PM SHIFT TIME 1 : 6:00 AM I50202 APR 6, 2023 12:18 PM SHIFT TIME 2 : DISABLED I50203 APR 6, 2023 12:18 PM SHIFT TIME 3 : DISABLED I50204 APR 6, 2023 12:18 PM SHIFT TIME 4 : DISABLED I54600 APR 6, 2023 12:18 PM TANK PER TST NEEDED WRN: DISABLED I54900 APR 6, 2023 12:18 PM TANK ANN TST NEEDED WRN: DISABLED I55300 APR 6, 2023 12:18 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 APR 6, 2023 12:18 PM LINE PER TST NEEDED WRN: DISABLED I55900 APR 6, 2023 12:18 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 APR 6, 2023 12:18 PM PRINT TC VOLUMES ENABLED I50E00 APR 6, 2023 12:18 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 APR 6, 2023 12:18 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 APR 6, 2023 12:18 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 APR 6, 2023 12:18 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 APR 6, 2023 12:18 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 APR 6, 2023 12:18 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 APR 6, 2023 12:18 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 APR 6, 2023 12:18 PM TANK CHART SECURITY DISABLED I5BD00 APR 6, 2023 12:18 PM CUSTOM ALARM LABELS DISABLED I56000 APR 6, 2023 12:18 PM MASS/DENSITY DISABLED I88101 APR 6, 2023 12:18 PM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 APR 6, 2023 12:18 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 APR 6, 2023 12:18 PM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 APR 6, 2023 12:18 PM I88105 APR 6, 2023 12:18 PM I88106 APR 6, 2023 12:18 PM I52000 APR 6, 2023 12:18 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUL 11, 2017 DISABLED 2 ON DATE JUL 11, 2017 DISABLED 3 ON DATE JUL 11, 2017 DISABLED 4 ON DATE JUL 11, 2017 DISABLED 5 ON DATE JUL 11, 2017 DISABLED 6 ON DATE JUL 11, 2017 DISABLED 7 ON DATE JUL 11, 2017 DISABLED 8 ON DATE JUL 11, 2017 DISABLED I60100 APR 6, 2023 12:18 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 UNL 2 ON 3 PNL ON 4 DIESEL ON I60200 APR 6, 2023 12:18 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 UNL 2 3 PNL 4 DIESEL I60300 APR 6, 2023 12:18 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 2 3 PNL 3 4 DIESEL 4 I60900 APR 6, 2023 12:18 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 UNL 2 0.000700 3 PNL 0.000700 4 DIESEL 0.000450 I60700 APR 6, 2023 12:18 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 111.50 2 UNL 2 111.50 3 PNL 111.50 4 DIESEL 111.50 I60A00 APR 6, 2023 12:18 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12062 2 UNL 2 1 PT 12062 3 PNL 1 PT 12062 4 DIESEL 1 PT 12062 I60400 APR 6, 2023 12:18 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I60500 APR 6, 2023 12:18 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 2 UNL 2 12062 0 0 0 3 PNL 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 APR 6, 2023 12:18 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 APR 6, 2023 12:18 PM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 UNL 2 NO 3 PNL NO 4 DIESEL NO I62F00 APR 6, 2023 12:18 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 3.0 IN. 2 UNL 2 3.0 IN. 3 PNL 4.0 IN. 4 DIESEL 4.0 IN. I62700 APR 6, 2023 12:18 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 UNL 2 2.0 3 PNL 2.0 4 DIESEL 2.0 I64200 APR 6, 2023 12:18 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 UNL 2 LOW 3 PNL LOW 4 DIESEL LOW I62400 APR 6, 2023 12:18 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 UNL 2 3.0 3 PNL 3.0 4 DIESEL 3.0 I62800 APR 6, 2023 12:18 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I62300 APR 6, 2023 12:18 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10856 2 UNL 2 10856 3 PNL 10856 4 DIESEL 10856 I62200 APR 6, 2023 12:18 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11459 2 UNL 2 11459 3 PNL 11459 4 DIESEL 11459 I62900 APR 6, 2023 12:18 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1809 2 UNL 2 1809 3 PNL 1809 4 DIESEL 1809 I62100 APR 6, 2023 12:19 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 500 2 UNL 2 500 3 PNL 500 4 DIESEL 500 I62600 APR 6, 2023 12:19 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I62500 APR 6, 2023 12:19 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 150 3 PNL 99 4 DIESEL 99 I60800 APR 6, 2023 12:19 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 2.00 2 UNL 2 2.00 3 PNL 0.00 4 DIESEL 0.00 I60B00 APR 6, 2023 12:19 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 APR 6, 2023 12:19 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 UNL 2 0.00 3 PNL 0.00 4 DIESEL 0.00 I61200 APR 6, 2023 12:19 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 NONE NONE 2 UNL 2 NONE NONE 3 PNL NONE NONE 4 DIESEL NONE NONE I63600 APR 6, 2023 12:19 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62A00 APR 6, 2023 12:19 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62C00 APR 6, 2023 12:19 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 UNL 2 STANDARD 3 PNL STANDARD 4 DIESEL STANDARD I62D00 APR 6, 2023 12:19 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 APR 6, 2023 12:19 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 UNL 2 OFF OFF 3 PNL OFF OFF 4 DIESEL OFF OFF I63000 APR 6, 2023 12:19 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I63200 APR 6, 2023 12:19 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I61000 APR 6, 2023 12:19 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63A00 APR 6, 2023 12:19 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 UNL 2 10.00% 3 PNL 10.00% 4 DIESEL 10.00% I61100 APR 6, 2023 12:19 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 16, 2006 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 APR 6, 2023 12:19 PM CSLD PROBABLITY OF DETECTION I61400 APR 6, 2023 12:19 PM CSLD CLIMATE FACTOR I61600 APR 6, 2023 12:19 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 UNL 2 IMMEDIATE 3 PNL IMMEDIATE 4 DIESEL IMMEDIATE I61A00 APR 6, 2023 12:19 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 UNL 2 DISABLED 3 PNL DISABLED 4 DIESEL DISABLED I61B00 APR 6, 2023 12:19 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 APR 6, 2023 12:19 PM CSLD REPORT ONLY I62B00 APR 6, 2023 12:19 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 UNL 2 ??? 0, 0 3 PNL ??? 0, 0 4 DIESEL ??? 0, 0 I63300 APR 6, 2023 12:19 PM LEAK TEST REPORT FORMAT: NORMAL I63400 APR 6, 2023 12:19 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 UNL 2 0 3 PNL 0 4 DIESEL 0 I63500 APR 6, 2023 12:19 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63900 APR 6, 2023 12:19 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 UNL 2 END FACTOR: NONE 3 PNL END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 APR 6, 2023 12:19 PM I77700 APR 6, 2023 12:19 PM I77800 APR 6, 2023 12:19 PM I78C00 APR 6, 2023 12:19 PM I78300 APR 6, 2023 12:19 PM I78F00 APR 6, 2023 12:19 PM I78700 APR 6, 2023 12:19 PM I70200 APR 6, 2023 12:19 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DIESEL STP 4 DIESEL ANN 5 REG2 STP 6 REG 2 ANN 7 SUPER STP 8 SUPER ANN 9 DISP 1-2 10 DISP 7-8 11 DISP 5-6 12 DISP 3-4 13 T1 87 ANN 14 SO.TRANS 15 16 I70300 APR 6, 2023 12:19 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 REG2 STP TRI-STATE (SINGLE FLOAT) 6 REG 2 ANN TRI-STATE (SINGLE FLOAT) 7 SUPER STP TRI-STATE (SINGLE FLOAT) 8 SUPER ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 7-8 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 T1 87 ANN TRI-STATE (SINGLE FLOAT) 14 SO.TRANS TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 APR 6, 2023 12:19 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN OTHER SENSORS 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 REG2 STP STP SUMP 6 REG 2 ANN ANNULAR SPACE 7 SUPER STP STP SUMP 8 SUPER ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 7-8 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 T1 87 ANN ANNULAR SPACE 14 SO.TRANS OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 APR 6, 2023 12:19 PM I74300 APR 6, 2023 12:19 PM I74400 APR 6, 2023 12:19 PM I74700 APR 6, 2023 12:19 PM I74800 APR 6, 2023 12:19 PM I74900 APR 6, 2023 12:19 PM I7BC00 APR 6, 2023 12:19 PM I80200 APR 6, 2023 12:19 PM I80300 APR 6, 2023 12:19 PM I80400 APR 6, 2023 12:19 PM I80700 APR 6, 2023 12:19 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DIESEL 4 OVERFILL ALARM I80900 APR 6, 2023 12:19 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 APR 6, 2023 12:19 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DIESEL 4 4 OVERFILL ALARM NONE I80A00 APR 6, 2023 12:19 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 APR 6, 2023 12:19 PM I80800 APR 6, 2023 12:19 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 3:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 APR 6, 2023 12:20 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 APR 6, 2023 12:20 PM I72300 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNKNOWN 02 F.M DISP 1-2 AIR FLOW METER 03 F.M DISP 3-4 AIR FLOW METER 04 F.M DISP 5-6 AIR FLOW METER 05 F.M DISP 7-8 AIR FLOW METER 06 V.P. 1-2 VAPOR PRESSURE 07 UNKNOWN 08 VP 1-2 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 VAPOR PROCESSOR TYPE NONE IV4700 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ACCEPT HIGH ORVR: YES IV4A00 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 APR 6, 2023 12:20 PM ISD VERSION: 01.07 Alarm History After. Responses Received: I10200 APR 6, 2023 12:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39572 39471 2 4 PROBE / G.T. 163706 163289 3 INTERSTITIAL BD 202336 202110 4 INTERSTITIAL BD 201545 201497 5 UNUSED 4949561 4924118 6 UNUSED 4943889 4921733 7 UNUSED 4944139 4921482 8 UNUSED 4942950 4921293 9 STP SENSE BOARD 33207 33208 10 UNUSED 4944389 4923654 11 RELAY BOARD 14993 14993 12 UNUSED 4944911 4918611 13 UNUSED 4944223 4919658 14 UNUSED 4943826 4918067 15 UNUSED 4947267 4914949 16 UNUSED 4945182 4914887 COMM 1 RS232 SERIAL BD 15014 15035 COMM 2 RS232 SERIAL BD 15035 15035 COMM 3 ELEC DISP INT. 101659 101410 COMM 4 UNUSED 4947059 4920620 COMM 5 UNUSED 4945474 4918758 COMM 6 UNUSED 4946183 4919030 I90200 APR 6, 2023 12:21 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 APR 6, 2023 12:21 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM CLEAR 4-06-23 12:03PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 4-06-23 12:03PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 4-06-23 12:03PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 4-06-23 12:03PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 4-06-23 12:03PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 4-06-23 12:03PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 4-06-23 12:02PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 4-06-23 12:02PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM ALARM 4-06-23 12:02PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 4-06-23 12:02PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 4-06-23 12:02PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 4-06-23 12:02PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 4-06-23 12:02PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 4-06-23 12:00PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 4-06-23 12:00PM L 7 STP SUMP SUPER STP FUEL ALARM CLEAR 4-06-23 11:59AM L 7 STP SUMP SUPER STP FUEL ALARM ALARM 4-06-23 11:59AM L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 4-06-23 11:58AM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 4-06-23 11:58AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 4-06-23 11:58AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 4-06-23 11:57AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 4-06-23 11:56AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 4-06-23 11:56AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 4-06-23 11:55AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 4-06-23 11:55AM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 4-06-23 11:54AM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 4-06-23 11:54AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 4-06-23 11:54AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 4-06-23 11:53AM L13 ANNULAR T1 87 ANN FUEL ALARM CLEAR 4-06-23 11:53AM L13 ANNULAR T1 87 ANN FUEL ALARM ALARM 4-06-23 11:52AM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 4-06-23 11:51AM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 4-06-23 11:51AM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 4-06-23 11:51AM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 4-06-23 11:50AM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 4-06-23 11:50AM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 4-06-23 11:50AM SYSTEM BATTERY IS OFF CLEAR 2-13-21 8:07AM SYSTEM BATTERY IS OFF ALARM 2-13-21 8:00AM I11200 APR 6, 2023 12:21 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME I20600 APR 6, 2023 12:21 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 TANK 2 UNL 2 TANK 3 PNL TANK 4 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 6, 2023 12:21 PM I30200 APR 6, 2023 12:21 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 11:57 AM FUEL ALARM 3 DIESEL STP APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 12:00 PM FUEL ALARM 4 DIESEL ANN APR 6, 2023 12:03 PM SENSOR OUT ALARM APR 6, 2023 11:50 AM FUEL ALARM 5 REG2 STP APR 6, 2023 12:03 PM SENSOR OUT ALARM APR 6, 2023 11:58 AM FUEL ALARM 6 REG 2 ANN APR 6, 2023 12:03 PM SENSOR OUT ALARM APR 6, 2023 11:51 AM FUEL ALARM 7 SUPER STP APR 6, 2023 12:03 PM SENSOR OUT ALARM APR 6, 2023 11:59 AM FUEL ALARM 8 SUPER ANN APR 6, 2023 12:03 PM SENSOR OUT ALARM APR 6, 2023 11:50 AM FUEL ALARM 9 DISP 1-2 APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 11:53 AM FUEL ALARM 10 DISP 7-8 APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 11:55 AM FUEL ALARM 11 DISP 5-6 APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 11:56 AM FUEL ALARM 12 DISP 3-4 APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 11:54 AM FUEL ALARM 13 T1 87 ANN APR 6, 2023 12:02 PM SENSOR OUT ALARM APR 6, 2023 11:52 AM FUEL ALARM I31600 APR 6, 2023 12:21 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 APR 6, 2023 12:21 PM I40300 APR 6, 2023 12:21 PM I34200 APR 6, 2023 12:21 PM I34700 APR 6, 2023 12:21 PM IV0100 APR 6, 2023 12:21 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-28 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.30 23-03-27 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.44 23-03-25 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.93 23-03-22 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 16.80 23-03-02 10:02:40 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-02-27 10:02:41 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-02-03 10:03:33 A/L RATIO DEGRADATION FP 5 BLEND3 BLKD 23-02-03 10:03:33 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-01-04 10:02:06 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.31 22-11-22 10:02:28 SENSOR OUT SELFTEST s 5 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-05-25 10:02:51 A/L RATIO DEGRADATION FP 5 BLEND3 0.70 22-04-30 10:02:15 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-04-06 12:03:45 READINESS ISD:PF EVR:NNN CHECK ISD SENSORS 23-04-06 12:03:45 ISD STARTUP 23-04-06 12:03:38 ISD SHUTDOWN 23-04-06 11:40:00 TIME CHANGE DETECTED AT: 23-04-06 08:07:49 23-04-06 08:07:40 TIME CHANGE DETECTED AT: 21-02-13 08:07:39 23-03-30 17:44:48 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 23-03-12 03:00:00 TIME CHANGE DETECTED AT: 23-03-12 02:00:13 23-02-17 10:02:17 READINESS ISD:PP EVR:PP ISD & EVR READY 23-02-16 10:02:25 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-02-15 10:02:36 READINESS ISD:PP EVR:NP EVR READINESS PENDING