Loading...
HomeMy WebLinkAbout2023 FMCAppendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10134208 4/26/2023 Jaco #3351 Howard's #4 3200 Panama Lane Bakersfield 93313 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 Veeder Root ATG B47853 7/30/2024 VMI 3924 10/24/2024 4/26/2023 7 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 2-1 / 208/304 87-1 STP L2 2-1 / 208/304 87-1 Fill L3 2-1 / 208/304 87-2 STP L4 2-1 / 208/304 87-2 Fill L5 2-1 / 208/304 91 STP L6 2-1 / 208/304 91 Fill L7 2-1 / 208/304 DSL STP L8 2-1 / 208/304 DSL Fill L9 2-1 / 208/304 Disp 1-2 L10 2-1 / 208/304 Disp 3-4 L11 2-1 / 208/304 Disp 5-6 L12 2-1 / 208/304 Disp 7-8 L13 2-1 / 208/304 Vent box Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Q1 848480-001 87-1, 87-2 Q2 848480-001 Prem Q3 848480-001 DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Probes are not due for testing per Marty w/ BFD. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. STP PROPERTY LINE NO PARKING 4 3 8 7 65 21 STP STP STP F F F FV V V 12,000 GALLON87-1 UNLEADED 12,000 GALLON87-2 UNLEADED 12,000 GALLONPREMIUM 12,000 GALLONDIESEL H PANAMA LN.WIBLE RD.EXISTING BUILDING W CATCHBASINPRICE SIGNDUMPSTER GATED ENCLOSURE WITHA STAND ALONE ROOF PROPERTY LINE N V-GUTTER SWITCHGEAR 87 GAS 1.5" OMEGAFLEX PIPE 91 GAS 1.5" OMEGAFLEX PIPE DIESEL 1.5" OMEGAFLEX PIPE VAPOR RETURN 3/2 INCH DBL WALL PIPE VAPOR RETURN 3/2 INCH MANIFOLDS VAPOR RETURN 4/3 INCH DBL WALL PIPE VAPOR VENT 3/2 INCH DBL WALL PIPE VACUUM CROSSOVER 3/2 DBL WALL PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER WATER SHUT OFF HEALY CAS EVACUATION MEETING POINT AUTOMATIC TANK GAUGE UST ELECTRICAL PANEL CIRCUIT BREAKER AIR AND WATER DISPENSER HAZWASTE DRUM H F V W S1 87-1 PRODUCT LINE SMART SENSOR S2 87-1 VENT LINE SMART SENSOR S3 87-1 TANK ANNULAR SMART SENSOR S4 87-2 PRODUCT LINE SMART SENSOR S5 87-2 VENT LINE SMART SENSOR S6 87-2 TANK ANNULAR SMART SENSOR S7 87-2 VAPOR LINE SMART SENSOR S8 TEMPERATURE SENSOR METER S9 PREMIUM PRODUCT SMART SENSOR S10 PREMIUM VENT LINE SMART SENSOR S11 PREMIUM TANK ANNULAR SMART SENSOR S12 DIESEL PRODUCT SMART SENSOR S13 DIESEL VENT LINE SMART SENSOR S14 DIESEL TANK ANNULAR SMART SENSOR LEGEND L1 87-1 STP SUMP L2 87-1 FILL SUMP L3 87-2 STP SUMP L4 87-2 FILL SUMP L5 PREMIUM STP SUMP L6 PREMIUM FILL SUMP L7 DIESEL STP SUMP L8 DIESEL FILL SUMP L9 UDC 1-2 L10 UDC 3-4 L11 UDC 5-6 L12 UDC 7-8 L13 VENT BOX DATE: DRAWN BY: CHECKED: APPROVED: RAC FASTRIP - 3351 CADFILE: SHEET NO.3351-MSP HOWARD'S MINI MARKETCONVENIENCE MARKET FOR: BAKERSFIELD, CALIFORNIA 933133200 PANAMA LN. DRAWING: DATE REVISIONS A.P.N.: 372-021-33 SCALE: JACO HILL3101 STATE RDBAKERSFIELD, CA 93308 PROJECT OWNER: CD SITE MAP SITE PLAN C1 VICINITY MAP TAB:CERS 1/8"=1'-0" 0 SHEET SIZE 22 X 34 3200 PANAMA LN.BAKERSFIELD, CA 93313 PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-46941 CERS ID 10134208 FASTRIP #3351 3200 PANAMA LN. BAKERSFIELD, CA 93313 03/01/2021 REV.WIBLE RD. PANAMA LN. 03/01/2021 PROJECT DATA 5'10'15' 20' L1,S1,S2,S3 L2 L3,S4,S5,S6,S7 L4 L5,S9,S10,S11 L6 L7,S12,S13,S14 L8 L11 L9 L10 L12 VAPOR MANIFOLDCAPPED L13 APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #3351 Howard's #43200 Panama LaneBakersfield101342083-47-8MPDMPD MPD MPD 1-25-6ProductProductProductProductAaron Perrigo Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10134208 4/26/2023 Jaco #3351 Howard's #4 3200 Panama Lane Bakersfield 93313 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 Emco PEI-1200 Lake test on all 4 fill spill buckets 4/26/2023 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. 87-1 Emco 87-2 Emco 91 Emco DSL Emco Jaco 3351 Setup Responses Received: 200 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 APR 26, 2023 9:00 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 87-1 UNLEADED 9643 71.48 0.0 66.3 2357 2 87-2 UNLEADED 10079 74.69 0.0 67.4 1921 3 91 PREMIUM 3932 34.54 0.0 72.2 8068 4 DIESEL 3397 31.01 0.0 71.8 8603 I90500 APR 26, 2023 9:00 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-066-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I50500 APR 26, 2023 9:01 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 APR 26, 2023 9:01 AM SHIFT TIME 1 : DISABLED I50202 APR 26, 2023 9:01 AM SHIFT TIME 2 : DISABLED I50203 APR 26, 2023 9:01 AM SHIFT TIME 3 : DISABLED I50204 APR 26, 2023 9:01 AM SHIFT TIME 4 : DISABLED I54600 APR 26, 2023 9:01 AM TANK PER TST NEEDED WRN: DISABLED I54900 APR 26, 2023 9:01 AM TANK ANN TST NEEDED WRN: DISABLED I55300 APR 26, 2023 9:01 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 APR 26, 2023 9:01 AM LINE PER TST NEEDED WRN: DISABLED I55900 APR 26, 2023 9:01 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 APR 26, 2023 9:01 AM PRINT TC VOLUMES ENABLED I50E00 APR 26, 2023 9:01 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 APR 26, 2023 9:01 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 APR 26, 2023 9:01 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 APR 26, 2023 9:01 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 APR 26, 2023 9:01 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 APR 26, 2023 9:01 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 APR 26, 2023 9:01 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 APR 26, 2023 9:01 AM TANK CHART SECURITY DISABLED I5BD00 APR 26, 2023 9:01 AM CUSTOM ALARM LABELS DISABLED I56000 APR 26, 2023 9:01 AM MASS/DENSITY DISABLED I88101 APR 26, 2023 9:01 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 APR 26, 2023 9:01 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 APR 26, 2023 9:01 AM I88104 APR 26, 2023 9:01 AM I88105 APR 26, 2023 9:01 AM PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 2400 PARITY : EVEN STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88106 APR 26, 2023 9:01 AM PORT SETTINGS: COMM BOARD : 6 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I52000 APR 26, 2023 9:01 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 26, 2023 DISABLED 2 ON DATE ??? 26, 2023 DISABLED 3 ON DATE ??? 26, 2023 DISABLED 4 ON DATE ??? 26, 2023 DISABLED 5 ON DATE ??? 26, 2023 DISABLED 6 ON DATE ??? 26, 2023 DISABLED 7 ON DATE ??? 26, 2023 DISABLED 8 ON DATE ??? 26, 2023 DISABLED I60100 APR 26, 2023 9:01 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 87-1 UNLEADED ON 2 87-2 UNLEADED ON 3 91 PREMIUM ON 4 DIESEL ON I60200 APR 26, 2023 9:01 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 87-1 UNLEADED 2 87-2 UNLEADED 3 91 PREMIUM 4 DIESEL I60300 APR 26, 2023 9:01 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 87-1 UNLEADED 1 2 87-2 UNLEADED 1 3 91 PREMIUM 2 4 DIESEL 3 I60900 APR 26, 2023 9:01 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 87-1 UNLEADED 0.000700 2 87-2 UNLEADED 0.000700 3 91 PREMIUM 0.000700 4 DIESEL 0.000450 I60700 APR 26, 2023 9:01 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 87-1 UNLEADED 96.00 2 87-2 UNLEADED 96.00 3 91 PREMIUM 96.00 4 DIESEL 96.00 I60A00 APR 26, 2023 9:01 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 87-1 UNLEADED 4 PTS 12032 2 87-2 UNLEADED 4 PTS 12032 3 91 PREMIUM 4 PTS 12032 4 DIESEL 4 PTS 12032 I60400 APR 26, 2023 9:01 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 12032 2 87-2 UNLEADED 12032 3 91 PREMIUM 12032 4 DIESEL 12032 I60500 APR 26, 2023 9:01 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 12032 9715 6056 2387 2 87-2 UNLEADED 12032 9715 6056 2387 3 91 PREMIUM 12032 9715 6056 2387 4 DIESEL 12032 9715 6056 2387 I60600 APR 26, 2023 9:01 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 12032 0 0 0 0 9715 0 0 0 0 6056 0 0 0 0 2387 0 0 0 0 2 87-2 UNLEADED 12032 0 0 0 0 9715 0 0 0 0 6056 0 0 0 0 2387 0 0 0 0 3 91 PREMIUM 12032 0 0 0 0 9715 0 0 0 0 6056 0 0 0 0 2387 0 0 0 0 4 DIESEL 12032 0 0 0 0 9715 0 0 0 0 6056 0 0 0 0 2387 0 0 0 0 I61500 APR 26, 2023 9:01 AM TANK PRODUCT LABEL METER DATA 1 87-1 UNLEADED NO 2 87-2 UNLEADED NO 3 91 PREMIUM NO 4 DIESEL NO I62F00 APR 26, 2023 9:01 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 87-1 UNLEADED 4.0 IN. 2 87-2 UNLEADED 4.0 IN. 3 91 PREMIUM 3.0 IN. 4 DIESEL 4.0 IN. I62700 APR 26, 2023 9:01 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 87-1 UNLEADED 2.0 2 87-2 UNLEADED 2.0 3 91 PREMIUM 2.0 4 DIESEL 2.0 I64200 APR 26, 2023 9:01 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 87-1 UNLEADED LOW 2 87-2 UNLEADED LOW 3 91 PREMIUM LOW 4 DIESEL LOW I62400 APR 26, 2023 9:01 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 87-1 UNLEADED 3.0 2 87-2 UNLEADED 3.0 3 91 PREMIUM 3.0 4 DIESEL 3.0 I62800 APR 26, 2023 9:01 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 12000 2 87-2 UNLEADED 12000 3 91 PREMIUM 12000 4 DIESEL 12000 I62300 APR 26, 2023 9:01 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 10800 2 87-2 UNLEADED 10800 3 91 PREMIUM 10800 4 DIESEL 10800 I62200 APR 26, 2023 9:01 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 11400 2 87-2 UNLEADED 11400 3 91 PREMIUM 11400 4 DIESEL 11400 I62900 APR 26, 2023 9:01 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 1200 2 87-2 UNLEADED 1200 3 91 PREMIUM 1200 4 DIESEL 1200 I62100 APR 26, 2023 9:01 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 500 2 87-2 UNLEADED 500 3 91 PREMIUM 500 4 DIESEL 500 I62600 APR 26, 2023 9:01 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 99 2 87-2 UNLEADED 99 3 91 PREMIUM 99 4 DIESEL 99 I62500 APR 26, 2023 9:01 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 99 2 87-2 UNLEADED 99 3 91 PREMIUM 99 4 DIESEL 99 I60800 APR 26, 2023 9:01 AM TANK TILT TANK PRODUCT LABEL INCHES 1 87-1 UNLEADED 0.00 2 87-2 UNLEADED 0.00 3 91 PREMIUM 0.00 4 DIESEL 0.00 I60B00 APR 26, 2023 9:01 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 APR 26, 2023 9:01 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 87-1 UNLEADED 0.00 2 87-2 UNLEADED 0.00 3 91 PREMIUM 0.00 4 DIESEL 0.00 I61200 APR 26, 2023 9:01 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 87-1 UNLEADED NONE 2 2 87-2 UNLEADED NONE 1 3 91 PREMIUM NONE NONE 4 DIESEL NONE NONE I63600 APR 26, 2023 9:01 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 0 2 87-2 UNLEADED 0 3 91 PREMIUM 0 4 DIESEL 0 I62A00 APR 26, 2023 9:01 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 0 2 87-2 UNLEADED 0 3 91 PREMIUM 0 4 DIESEL 0 I62C00 APR 26, 2023 9:01 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 87-1 UNLEADED STANDARD 2 87-2 UNLEADED STANDARD 3 91 PREMIUM STANDARD 4 DIESEL STANDARD I62D00 APR 26, 2023 9:01 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 87-1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 87-2 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 91 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 APR 26, 2023 9:01 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 87-1 UNLEADED OFF OFF 2 87-2 UNLEADED OFF OFF 3 91 PREMIUM OFF OFF 4 DIESEL OFF OFF I63000 APR 26, 2023 9:01 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 87-1 UNLEADED OFF 2 87-2 UNLEADED OFF 3 91 PREMIUM OFF 4 DIESEL OFF I63200 APR 26, 2023 9:01 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 87-1 UNLEADED OFF 2 87-2 UNLEADED OFF 3 91 PREMIUM OFF 4 DIESEL OFF I61000 APR 26, 2023 9:01 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 87-1 UNLEADED 1 2 87-2 UNLEADED 1 3 91 PREMIUM 1 4 DIESEL 1 I63A00 APR 26, 2023 9:01 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 87-1 UNLEADED 10.00% 2 87-2 UNLEADED 10.00% 3 91 PREMIUM 10.00% 4 DIESEL 10.00% I61100 APR 26, 2023 9:01 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK AUG 27, 2018 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 APR 26, 2023 9:01 AM CSLD PROBABLITY OF DETECTION I61400 APR 26, 2023 9:01 AM CSLD CLIMATE FACTOR I61600 APR 26, 2023 9:01 AM TANK PRODUCT LABEL CAL UPDATE 1 87-1 UNLEADED IMMEDIATE 2 87-2 UNLEADED IMMEDIATE 3 91 PREMIUM IMMEDIATE 4 DIESEL IMMEDIATE I61A00 APR 26, 2023 9:01 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 87-1 UNLEADED DISABLED 2 87-2 UNLEADED DISABLED 3 91 PREMIUM DISABLED 4 DIESEL DISABLED I61B00 APR 26, 2023 9:01 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 APR 26, 2023 9:01 AM CSLD REPORT ONLY I62B00 APR 26, 2023 9:01 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 87-1 UNLEADED ??? 0, 0 2 87-2 UNLEADED ??? 0, 0 3 91 PREMIUM ??? 0, 0 4 DIESEL ??? 0, 0 I63300 APR 26, 2023 9:01 AM LEAK TEST REPORT FORMAT: NORMAL I63400 APR 26, 2023 9:01 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 0 2 87-2 UNLEADED 0 3 91 PREMIUM 0 4 DIESEL 0 I63500 APR 26, 2023 9:01 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87-1 UNLEADED 1 2 87-2 UNLEADED 1 3 91 PREMIUM 1 4 DIESEL 1 I63900 APR 26, 2023 9:01 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 87-1 UNLEADED END FACTOR: NONE 2 87-2 UNLEADED END FACTOR: NONE 3 91 PREMIUM END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 APR 26, 2023 9:01 AM PRESSURE LINE LEAK SETUP Q 1:87 UNLEADED TYP:USER DEFINED 1ST LINE LEN: 170 FEET 2ND LINE LEN: 170 FEET 1ST LINE DIAM: 1.50 IN. 2ND LINE DIAM: 1.50 IN. 1ST BULK MOD: 31000 PSI 2ND BULK MOD: 31000 PSI THERMAL COEFF :0.000700 0.20 GPH TEST: DISABLED 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 2:87-2 UNLEADED DISPENSE MODE: MANIFOLDED: ALTERNATE-HT ACTIVE SWITCHOVER: ENABLED: NO SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:91 PREMIUM TYP:USER DEFINED 1ST LINE LEN: 160 FEET 2ND LINE LEN: 0 FEET 1ST LINE DIAM: 1.50 IN. 1ST BULK MOD: 31000 PSI THERMAL COEFF :0.000700 0.20 GPH TEST: DISABLED 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 3:91 PREMIUM DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:DIESEL TYP:USER DEFINED 1ST LINE LEN: 150 FEET 2ND LINE LEN: 0 FEET 1ST LINE DIAM: 1.50 IN. 1ST BULK MOD: 31000 PSI THERMAL COEFF :0.000700 0.20 GPH TEST: DISABLED 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 4:DIESEL DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO I77700 APR 26, 2023 9:01 AM PRESSURE LINE LEAK PRIMARY PIPE DIAMETER LINE 1ST LINE DIAMETER Q 1:87 UNLEADED 1.50 INCHES Q 2:91 PREMIUM 1.50 INCHES Q 3:DIESEL 1.50 INCHES I77800 APR 26, 2023 9:01 AM PRESSURE LINE LEAK SECONDARY PIPE DIAMETER LINE 2ND LINE DIAMETER Q 1:87 UNLEADED 1.50 INCHES I78C00 APR 26, 2023 9:01 AM PRESSURE LINE LEAK 0.20 TEST SCHEDULE LINE 0.20 GPH TEST Q 1:87 UNLEADED DISABLED Q 2:91 PREMIUM DISABLED Q 3:DIESEL DISABLED I78300 APR 26, 2023 9:01 AM PRESSURE LINE LEAK 0.10 TEST SCHEDULE LINE 0.10 GPH TEST Q 1:87 UNLEADED DISABLED Q 2:91 PREMIUM DISABLED Q 3:DIESEL DISABLED I78F00 APR 26, 2023 9:01 AM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSURE Q 1:87 UNLEADED 0 PSI Q 2:91 PREMIUM 0 PSI Q 3:DIESEL 0 PSI I78700 APR 26, 2023 9:01 AM PRESSURE LLD SETUP REPORT Q 1:87 UNLEADED LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL Q 2:91 PREMIUM LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL Q 3:DIESEL LIQUID SENSOR ALMS L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL I70200 APR 26, 2023 9:02 AM LIQUID LABEL DEVICE LABEL 1 87-1 STP 2 87-1 FILL 3 87-2 STP 4 87-2 FILL 5 91 STP 6 91 FILL 7 DIESEL STP 8 DIESEL FILL 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 VENT BOX 14 L 15 16 I70300 APR 26, 2023 9:02 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87-1 STP DW SUMP 2-1 2 87-1 FILL DW SUMP 2-1 3 87-2 STP DW SUMP 2-1 4 87-2 FILL DW SUMP 2-1 5 91 STP DW SUMP 2-1 6 91 FILL DW SUMP 2-1 7 DIESEL STP DW SUMP 2-1 8 DIESEL FILL DW SUMP 2-1 9 DISP 1-2 DW SUMP 2-1 10 DISP 3-4 DW SUMP 2-1 11 DISP 5-6 DW SUMP 2-1 12 DISP 7-8 DW SUMP 2-1 13 VENT BOX DW SUMP 2-1 14 L DW SUMP 2-1 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 APR 26, 2023 9:02 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87-1 STP STP SUMP 2 87-1 FILL PIPING SUMP 3 87-2 STP STP SUMP 4 87-2 FILL PIPING SUMP 5 91 STP STP SUMP 6 91 FILL PIPING SUMP 7 DIESEL STP STP SUMP 8 DIESEL FILL PIPING SUMP 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 VENT BOX PIPING SUMP 14 L PIPING SUMP 15 OTHER SENSORS 16 OTHER SENSORS I74200 APR 26, 2023 9:02 AM I74300 APR 26, 2023 9:02 AM I74400 APR 26, 2023 9:02 AM I74700 APR 26, 2023 9:02 AM I74800 APR 26, 2023 9:02 AM I74900 APR 26, 2023 9:02 AM I7BC00 APR 26, 2023 9:02 AM I80200 APR 26, 2023 9:02 AM I80300 APR 26, 2023 9:02 AM I80400 APR 26, 2023 9:02 AM I80700 APR 26, 2023 9:02 AM RELAY LABEL DEVICE LABEL 1 87-1 TURBINE 2 87-1 UNLEADED 3 91 PREMIUM 4 DIESEL 5 87-2 UNLEADED 6 7 8 I80900 APR 26, 2023 9:02 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87-1 TURBINE NORMALLY OPEN 2 87-1 UNLEADED NORMALLY OPEN 3 91 PREMIUM NORMALLY OPEN 4 DIESEL NORMALLY OPEN 5 87-2 UNLEADED NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 APR 26, 2023 9:02 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87-1 TURBINE 1 2 87-1 UNLEADED NONE 3 91 PREMIUM NONE 4 DIESEL NONE 5 87-2 UNLEADED NONE 6 1 7 1 8 1 I80A00 APR 26, 2023 9:02 AM RELAY TYPE RELAY DESIGNATION TYPE 1 87-1 TURBINE PUMP CONTROL OUTPUT 2 87-1 UNLEADED STANDARD 3 91 PREMIUM STANDARD 4 DIESEL STANDARD 5 87-2 UNLEADED STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 APR 26, 2023 9:02 AM I80800 APR 26, 2023 9:02 AM RELAY SETUP REPORT R 1:87-1 TURBINE TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM PRESSURE LINE LEAK Q 1:GROSS LINE FAIL Q 1:PLLD SHUTDOWN ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 2:87-1 UNLEADED TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS T 1:OVERFILL ALARM T 1:HIGH PRODUCT ALARM R 3:91 PREMIUM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS T 3:OVERFILL ALARM T 3:HIGH PRODUCT ALARM R 4:DIESEL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS T 4:OVERFILL ALARM T 4:HIGH PRODUCT ALARM R 5:87-2 UNLEADED TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS T 2:OVERFILL ALARM T 2:HIGH PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: 1 - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: 1 - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: 1 - NO ALARM ASSIGNMENTS - I79000 APR 26, 2023 9:03 AM EDIM:1 VR:349867-001-D TD:17.02.14.08.38 I79100 APR 26, 2023 9:03 AM I72300 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 87-1 PRODUCT VAC SENSOR 02 87-1 VENT VAC SENSOR 03 87-1 TANK VAC SENSOR 04 87-2 PRODUCT VAC SENSOR 05 87-2 VENT VAC SENSOR 06 87-2 TANK VAC SENSOR 07 87-2 VAPOR VAC SENSOR 08 ATM ATM P SENSOR 09 91 PRODUCT VAC SENSOR 10 91 VENT VAC SENSOR 11 91 TANK VAC SENSOR 12 DIESEL PRODUCT VAC SENSOR 13 DIESEL VENT VAC SENSOR 14 DIESEL TANK VAC SENSOR 15 UNKNOWN 16 UNKNOWN 17 DISP 1-2 FM AIR FLOW METER 18 DISP 3-4 FM AIR FLOW METER 19 DISP 5-6 FM AIR FLOW METER 20 DISP 7-8 FM AIR FLOW METER 21 DISP 1-2 PRES SENSR VAPOR PRESSURE 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 VAPOR PROCESSOR TYPE NONE IV4700 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 ASSESSMENT TIME START TIME: 10:05 AM TIME DELAY MINUTES: 1 IV5200 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 ACCEPT HIGH ORVR: NO IV4A00 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 01 BLEND3 02 02 02 01 01 BLEND3 03 03 03 02 01 BLEND3 04 04 04 02 01 BLEND3 05 05 05 03 01 BLEND3 06 06 06 03 01 BLEND3 07 07 07 04 01 BLEND3 08 08 08 04 01 BLEND3 IV4B00 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 01/01 09/01 xx/xx 02 01 02/02 01/02 09/02 xx/xx 03 02 02/03 01/03 09/03 xx/xx 04 02 02/04 01/04 09/04 xx/xx 05 03 02/05 01/05 09/05 xx/xx 06 03 02/06 01/06 09/06 xx/xx 07 04 02/07 01/07 09/07 xx/xx 08 04 02/08 01/08 09/08 xx/xx IV4900 APR 26, 2023 9:03 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 APR 26, 2023 9:03 AM ISD VERSION: 01.05 Jaco 3351 Alarm History Responses Received: I10200 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162966 162992 2 PLLD SENSOR BD 3849 3858 3 7SMARTSENSOR BD 504314 504295 4 8SMARTSENSOR BD 39214 39219 5 8SMARTSENSOR BD 39193 39219 6 INTERSTITIAL BD 200899 200760 7 INTERSTITIAL BD 200433 200313 8 UNUSED 4979078 4998613 9 RELAY BOARD 14966 14959 10 PLLD POWER BD 100334 100336 11 RELAY BOARD 4983978 14959 12 UNUSED 4978294 4994131 13 UNUSED 4981105 4998130 14 UNUSED 4979608 4995801 15 UNUSED 4976878 4993636 16 UNUSED 4979936 4993204 COMM 1 ELEC DISP INT. 100505 100615 COMM 2 RS232 SERIAL BD 14821 14814 COMM 3 UNUSED 4983096 4994585 COMM 4 UNUSED 4971195 4995533 COMM 5 RS485 SERIAL BD 68187 68341 COMM 6 RS232 SERIAL BD 14842 14834 I90200 APR 26, 2023 9:04 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-066-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME E 1 OTHER G COMMUNICATION ALARM CLEAR 4-25-23 7:50AM E 1 OTHER G COMMUNICATION ALARM ALARM 4-25-23 7:50AM E 1 OTHER G COMMUNICATION ALARM CLEAR 4-25-23 7:50AM E 1 OTHER G COMMUNICATION ALARM ALARM 4-24-23 11:03PM E 1 OTHER G COMMUNICATION ALARM CLEAR 4-24-23 2:13AM E 1 OTHER G COMMUNICATION ALARM ALARM 4-24-23 2:10AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM CLEAR 4-17-23 11:06AM Q 1 OTHER 87 UNLEADED GROSS LINE FAIL CLEAR 4-17-23 11:06AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM ALARM 4-17-23 11:05AM Q 1 OTHER 87 UNLEADED GROSS LINE FAIL ALARM 4-17-23 11:05AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM CLEAR 4-17-23 10:52AM Q 2 OTHER 91 PREMIUM GROSS LINE FAIL CLEAR 4-17-23 10:52AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM ALARM 4-17-23 10:51AM Q 2 OTHER 91 PREMIUM GROSS LINE FAIL ALARM 4-17-23 10:51AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 4-17-23 10:46AM Q 3 OTHER DIESEL GROSS LINE FAIL CLEAR 4-17-23 10:46AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 4-17-23 10:44AM Q 3 OTHER DIESEL GROSS LINE FAIL ALARM 4-17-23 10:44AM L 4 PIPE 87-2 FILL SENSOR OUT ALARM CLEAR 4-17-23 10:24AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM CLEAR 4-17-23 10:24AM L 3 STP SUMP 87-2 STP SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 2 PIPE 87-1 FILL SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 1 STP SUMP 87-1 STP SENSOR OUT ALARM CLEAR 4-17-23 10:24AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 4-17-23 10:24AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 6 PIPE 91 FILL SENSOR OUT ALARM CLEAR 4-17-23 10:24AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM CLEAR 4-17-23 10:24AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 8 PIPE DIESEL FILL SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L13 PIPE VENT BOX SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 5 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 4-17-23 10:24AM L 6 PIPE 91 FILL SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 4 PIPE 87-2 FILL SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 2 PIPE 87-1 FILL SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 3 STP SUMP 87-2 STP SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 1 STP SUMP 87-1 STP SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 5 STP SUMP 91 STP SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 8 PIPE DIESEL FILL SENSOR OUT ALARM ALARM 4-17-23 10:23AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 4-17-23 10:23AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 4-17-23 10:23AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 4-17-23 10:23AM L13 PIPE VENT BOX SENSOR OUT ALARM ALARM 4-17-23 10:23AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 4-17-23 10:22AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 4-17-23 10:22AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM ALARM 4-17-23 10:22AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM ALARM 4-17-23 10:22AM I11200 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK DIESEL DELIVERY NEEDED CLEAR 4-22-23 7:32PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 4-21-23 11:31AM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:22PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:22PM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:22PM SYSTEM PAPER OUT CLEAR 4-13-23 8:22PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:21PM SYSTEM PAPER OUT ALARM 4-13-23 8:21PM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:21PM SYSTEM PAPER OUT CLEAR 4-13-23 8:21PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:21PM SYSTEM PAPER OUT ALARM 4-13-23 8:21PM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:21PM SYSTEM PAPER OUT CLEAR 4-13-23 8:21PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:20PM SYSTEM PAPER OUT ALARM 4-13-23 8:20PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 4-12-23 11:49AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 4-12-23 9:21AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 3-28-23 6:41PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 3-27-23 5:54PM T 3 TANK 91 PREMIUM DELIVERY NEEDED CLEAR 3-26-23 2:52AM T 3 TANK 91 PREMIUM DELIVERY NEEDED ALARM 3-25-23 11:58PM T 3 TANK 91 PREMIUM DELIVERY NEEDED CLEAR 3-20-23 1:01AM T 3 TANK 91 PREMIUM DELIVERY NEEDED ALARM 3-19-23 4:30PM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 2-23-23 1:48PM T 4 TANK DIESEL LOW TEMP WARNING ALARM 2-23-23 1:47PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 2-23-23 1:03PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 2-23-23 12:54PM T 4 TANK DIESEL HIGH WATER WARNING CLEAR 2-23-23 12:47PM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 2-23-23 12:46PM T 4 TANK DIESEL LOW TEMP WARNING ALARM 2-23-23 12:44PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:34PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:30PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:30PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:28PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:26PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:25PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:23PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:23PM T 4 TANK DIESEL HIGH WATER WARNING ALARM 2-23-23 12:19PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:17PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:16PM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 2-23-23 12:13PM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 2-23-23 12:13PM T 4 TANK DIESEL HIGH WATER WARNING CLEAR 2-23-23 12:05PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 2-23-23 12:01PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 2-23-23 11:59AM T 4 TANK DIESEL HIGH WATER WARNING ALARM 2-23-23 11:57AM T 4 TANK DIESEL HIGH WATER WARNING CLEAR 2-23-23 11:57AM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 2-23-23 11:53AM I20600 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 TANK ALARM HISTORY TANK 1 87-1 UNLEADED OVERFILL ALARM DEC 29, 2022 12:20 PM DEC 29, 2022 12:17 PM AUG 29, 2022 1:41 AM HIGH PRODUCT ALARM AUG 15, 2022 2:05 PM PROBE OUT AUG 15, 2022 2:06 PM AUG 15, 2022 2:03 PM AUG 15, 2022 2:00 PM TANK 2 87-2 UNLEADED OVERFILL ALARM MAR 26, 2023 2:52 AM MAR 11, 2023 12:23 AM DEC 22, 2022 6:01 PM HIGH PRODUCT ALARM AUG 15, 2022 2:03 PM JUN 10, 2022 9:12 AM APR 9, 2022 5:54 AM PROBE OUT AUG 15, 2022 2:04 PM AUG 15, 2022 1:53 PM MAX PRODUCT ALARM JUN 10, 2022 9:12 AM APR 9, 2022 5:56 AM LOW TEMP WARNING AUG 15, 2022 2:04 PM TANK 3 91 PREMIUM OVERFILL ALARM AUG 15, 2022 2:02 PM LOW PRODUCT ALARM DEC 18, 2022 9:40 PM HIGH PRODUCT ALARM JUN 10, 2022 9:13 AM JUN 10, 2022 8:05 AM JUN 10, 2022 7:54 AM INVALID FUEL LEVEL DEC 18, 2022 7:44 PM PROBE OUT FEB 23, 2023 1:49 PM FEB 23, 2023 12:48 PM FEB 23, 2023 12:21 PM DELIVERY NEEDED MAR 25, 2023 11:58 PM MAR 19, 2023 4:30 PM FEB 8, 2023 4:22 PM MAX PRODUCT ALARM JUN 10, 2022 9:13 AM JUN 10, 2022 8:05 AM JUN 10, 2022 7:54 AM TANK 4 DIESEL HIGH WATER ALARM FEB 23, 2023 12:19 PM FEB 23, 2023 11:57 AM FEB 22, 2023 6:00 PM OVERFILL ALARM FEB 23, 2023 12:13 PM AUG 15, 2022 2:00 PM HIGH PRODUCT ALARM FEB 23, 2023 12:13 PM JUN 10, 2022 9:14 AM JUN 10, 2022 8:07 AM INVALID FUEL LEVEL FEB 23, 2023 12:30 PM FEB 23, 2023 12:28 PM FEB 23, 2023 12:25 PM PROBE OUT FEB 23, 2023 1:44 PM FEB 23, 2023 1:01 PM FEB 23, 2023 12:54 PM HIGH WATER WARNING FEB 23, 2023 12:19 PM FEB 23, 2023 11:57 AM FEB 22, 2023 6:00 PM DELIVERY NEEDED APR 21, 2023 11:31 AM APR 12, 2023 9:21 AM MAR 27, 2023 5:54 PM MAX PRODUCT ALARM FEB 23, 2023 12:13 PM JUN 10, 2022 9:14 AM JUN 10, 2022 8:07 AM LOW TEMP WARNING FEB 23, 2023 1:47 PM FEB 23, 2023 12:44 PM FEB 23, 2023 11:53 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:87 UNLEADED APR 17, 2023 11:05 AM PLLD SHUTDOWN ALARM APR 17, 2023 11:05 AM GROSS LINE FAIL APR 17, 2023 10:22 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:55 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:54 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:52 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:50 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:48 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:38 AM PLLD SHUTDOWN ALARM OCT 18, 2022 10:10 AM PLLD SHUTDOWN ALARM Q 2:91 PREMIUM APR 17, 2023 10:51 AM PLLD SHUTDOWN ALARM APR 17, 2023 10:51 AM GROSS LINE FAIL APR 17, 2023 10:22 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:55 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:54 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:52 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:50 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:40 AM PLLD SHUTDOWN ALARM OCT 18, 2022 10:10 AM PLLD SHUTDOWN ALARM APR 27, 2022 4:43 PM PLLD SHUTDOWN ALARM Q 3:DIESEL APR 17, 2023 10:44 AM PLLD SHUTDOWN ALARM APR 17, 2023 10:44 AM GROSS LINE FAIL APR 17, 2023 10:22 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:55 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:54 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:52 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:50 AM PLLD SHUTDOWN ALARM APR 17, 2023 9:43 AM PLLD SHUTDOWN ALARM DEC 27, 2022 5:54 PM PLLD SHUTDOWN ALARM DEC 7, 2022 12:03 AM PLLD SHUTDOWN ALARM I30200 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87-1 STP APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 9:59 AM LOW LIQUID ALARM APR 17, 2023 9:48 AM FUEL ALARM 2 87-1 FILL APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 10:07 AM LOW LIQUID ALARM APR 17, 2023 10:06 AM FUEL ALARM 3 87-2 STP APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 9:39 AM LOW LIQUID ALARM APR 17, 2023 9:38 AM FUEL ALARM 4 87-2 FILL APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 10:18 AM LOW LIQUID ALARM APR 17, 2023 10:08 AM FUEL ALARM 5 91 STP APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 9:41 AM LOW LIQUID ALARM APR 17, 2023 9:40 AM FUEL ALARM 6 91 FILL APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 10:13 AM FUEL ALARM APR 17, 2023 10:10 AM LOW LIQUID ALARM 7 DIESEL STP APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 9:59 AM LOW LIQUID ALARM APR 17, 2023 9:43 AM FUEL ALARM 8 DIESEL FILL APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 6, 2023 12:36 PM LOW LIQUID ALARM APR 6, 2023 12:28 PM SENSOR OUT ALARM 9 DISP 1-2 APR 17, 2023 10:22 AM SENSOR OUT ALARM APR 17, 2023 10:00 AM LOW LIQUID ALARM APR 17, 2023 9:55 AM FUEL ALARM 10 DISP 3-4 APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 10:00 AM LOW LIQUID ALARM APR 17, 2023 9:54 AM FUEL ALARM 11 DISP 5-6 APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 10:01 AM LOW LIQUID ALARM APR 17, 2023 9:50 AM FUEL ALARM 12 DISP 7-8 APR 17, 2023 10:23 AM SENSOR OUT ALARM APR 17, 2023 10:00 AM LOW LIQUID ALARM APR 17, 2023 9:52 AM FUEL ALARM 13 VENT BOX APR 17, 2023 10:23 AM SENSOR OUT ALARM OCT 22, 2022 12:49 AM LOW LIQUID ALARM OCT 21, 2022 1:13 AM LOW LIQUID ALARM I31600 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87-1 PRODUCT APR 27, 2022 11:55 AM HIGH LIQUID ALARM APR 27, 2022 11:40 AM HIGH LIQUID ALARM APR 27, 2022 11:39 AM NO VACUUM ALARM 2 87-1 VENT APR 27, 2022 11:55 AM HIGH LIQUID ALARM APR 27, 2022 11:39 AM NO VACUUM ALARM APR 5, 2022 10:24 AM NO VACUUM ALARM 3 87-1 TANK APR 27, 2022 1:57 PM HIGH LIQUID ALARM APR 27, 2022 1:19 PM NO VACUUM ALARM APR 5, 2022 10:32 AM NO VACUUM ALARM 4 87-2 PRODUCT APR 27, 2022 12:06 PM HIGH LIQUID ALARM APR 27, 2022 11:36 AM NO VACUUM ALARM APR 5, 2022 10:25 AM NO VACUUM ALARM 5 87-2 VENT APR 27, 2022 12:06 PM HIGH LIQUID ALARM APR 27, 2022 11:37 AM HIGH LIQUID ALARM APR 27, 2022 11:36 AM NO VACUUM ALARM 6 87-2 TANK APR 27, 2022 1:20 PM HIGH LIQUID ALARM APR 27, 2022 1:20 PM NO VACUUM ALARM APR 5, 2022 10:31 AM HIGH LIQUID ALARM 7 87-2 VAPOR APR 27, 2022 12:06 PM HIGH LIQUID ALARM APR 27, 2022 11:38 AM HIGH LIQUID ALARM APR 27, 2022 11:36 AM NO VACUUM ALARM 8 ATM 9 91 PRODUCT APR 27, 2022 11:49 AM HIGH LIQUID ALARM APR 27, 2022 11:33 AM NO VACUUM ALARM APR 5, 2022 10:26 AM NO VACUUM ALARM 10 91 VENT APR 27, 2022 11:49 AM HIGH LIQUID ALARM APR 27, 2022 11:34 AM NO VACUUM ALARM APR 5, 2022 10:26 AM HIGH LIQUID ALARM 11 91 TANK APR 17, 2023 9:40 AM NO VACUUM ALARM APR 27, 2022 1:21 PM HIGH LIQUID ALARM APR 27, 2022 1:21 PM NO VACUUM ALARM 12 DIESEL PRODUCT APR 27, 2022 11:51 AM HIGH LIQUID ALARM APR 27, 2022 11:29 AM NO VACUUM ALARM APR 5, 2022 10:28 AM HIGH LIQUID ALARM 13 DIESEL VENT APR 27, 2022 11:51 AM HIGH LIQUID ALARM APR 27, 2022 11:30 AM HIGH LIQUID ALARM APR 27, 2022 11:29 AM NO VACUUM ALARM 14 DIESEL TANK APR 27, 2022 1:21 PM HIGH LIQUID ALARM APR 27, 2022 1:21 PM NO VACUUM ALARM APR 5, 2022 10:29 AM HIGH LIQUID ALARM 17 DISP 1-2 FM 18 DISP 3-4 FM 19 DISP 5-6 FM 20 DISP 7-8 FM 21 DISP 1-2 PRES SENSR I40200 APR 26, 2023 9:04 AM I40300 APR 26, 2023 9:04 AM I34200 APR 26, 2023 9:04 AM I34700 APR 26, 2023 9:04 AM IV0100 APR 26, 2023 9:04 AM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-01-19 10:09:13 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.38 23-01-18 10:09:19 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.49 23-01-11 10:08:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.81 23-01-04 10:08:21 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.74 22-12-28 10:08:05 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.11 22-12-21 10:09:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.55 22-12-14 10:09:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.28 22-12-07 10:09:17 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.66 22-11-30 10:10:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.41 22-11-29 10:09:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.45 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-10-18 10:10:20 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.02 19-12-18 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 19-11-25 10:02:24 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 19-11-12 10:03:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.45 19-02-14 10:02:00 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 18-03-22 10:01:18 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 17-12-11 10:01:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.98 17-03-20 10:03:18 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.61 16-07-31 08:43:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.95 16-06-04 10:02:17 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-03-12 03:00:00 TIME CHANGE DETECTED AT: 23-03-12 02:00:13 23-03-03 10:10:08 READINESS ISD:PP EVR:PP ISD & EVR READY 23-03-02 16:21:36 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-03-02 16:21:36 ISD STARTUP 23-03-02 16:21:34 ISD SHUTDOWN 23-01-19 13:11:04 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 23-01-11 12:16:35 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 23-01-05 06:18:33 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 22-12-29 06:29:43 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 22-12-21 15:43:59 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED Jaco 3351 Alarm History After Responses Received: I10200 APR 26, 2023 12:04 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162966 162877 2 PLLD SENSOR BD 3849 3862 3 7SMARTSENSOR BD 504314 503638 4 8SMARTSENSOR BD 39214 39264 5 8SMARTSENSOR BD 39193 39201 6 INTERSTITIAL BD 200899 200994 7 INTERSTITIAL BD 200433 200546 8 UNUSED 4979078 4959979 9 RELAY BOARD 14966 14986 10 PLLD POWER BD 100334 100403 11 RELAY BOARD 4983978 14945 12 UNUSED 4978294 4958171 13 UNUSED 4981105 4960857 14 UNUSED 4979608 4954865 15 UNUSED 4976878 4958233 16 UNUSED 4979936 4956146 COMM 1 ELEC DISP INT. 100505 100596 COMM 2 RS232 SERIAL BD 14821 14841 COMM 3 UNUSED 4983096 4960650 COMM 4 UNUSED 4971195 4961352 COMM 5 RS485 SERIAL BD 68187 68328 COMM 6 RS232 SERIAL BD 14842 14862 I90200 APR 26, 2023 12:04 PM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-066-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:40AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:40AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:40AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 4-26-23 11:40AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 4-26-23 11:39AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 4-26-23 11:39AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM ALARM 4-26-23 11:39AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM ALARM 4-26-23 11:39AM s14 OTHER DIESEL TANK NO VACUUM ALARM CLEAR 4-26-23 11:36AM s14 OTHER DIESEL TANK HIGH LIQUID ALARM CLEAR 4-26-23 11:33AM s11 OTHER 91 TANK NO VACUUM ALARM CLEAR 4-26-23 11:29AM s 6 OTHER 87-2 TANK NO VACUUM ALARM CLEAR 4-26-23 11:29AM s 3 OTHER 87-1 TANK NO VACUUM ALARM CLEAR 4-26-23 11:26AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:25AM Q 3 OTHER DIESEL GROSS LINE FAIL CLEAR 4-26-23 11:25AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:24AM Q 2 OTHER 91 PREMIUM GROSS LINE FAIL CLEAR 4-26-23 11:24AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:24AM Q 1 OTHER 87 UNLEADED GROSS LINE FAIL CLEAR 4-26-23 11:24AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM ALARM 4-26-23 11:22AM Q 1 OTHER 87 UNLEADED GROSS LINE FAIL ALARM 4-26-23 11:22AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM ALARM 4-26-23 11:15AM Q 2 OTHER 91 PREMIUM GROSS LINE FAIL ALARM 4-26-23 11:15AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 4-26-23 11:10AM Q 3 OTHER DIESEL GROSS LINE FAIL ALARM 4-26-23 11:10AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:07AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:07AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM CLEAR 4-26-23 11:07AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 4-26-23 11:07AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 4-26-23 11:02AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 4-26-23 11:02AM Q 2 OTHER 91 PREMIUM PLLD SHUTDOWN ALARM ALARM 4-26-23 11:02AM Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM ALARM 4-26-23 11:02AM s 3 OTHER 87-1 TANK HIGH LIQUID ALARM CLEAR 4-26-23 10:49AM s 3 OTHER 87-1 TANK HIGH LIQUID ALARM ALARM 4-26-23 10:48AM s 3 OTHER 87-1 TANK NO VACUUM ALARM ALARM 4-26-23 10:48AM s 6 OTHER 87-2 TANK NO VACUUM ALARM ALARM 4-26-23 10:47AM s11 OTHER 91 TANK HIGH LIQUID ALARM CLEAR 4-26-23 10:46AM s11 OTHER 91 TANK HIGH LIQUID ALARM ALARM 4-26-23 10:45AM s11 OTHER 91 TANK NO VACUUM ALARM ALARM 4-26-23 10:45AM s14 OTHER DIESEL TANK HIGH LIQUID ALARM ALARM 4-26-23 10:43AM s14 OTHER DIESEL TANK NO VACUUM ALARM ALARM 4-26-23 10:43AM s12 OTHER DIESEL PRODUCT HIGH LIQUID ALARM CLEAR 4-26-23 10:42AM s13 OTHER DIESEL VENT HIGH LIQUID ALARM CLEAR 4-26-23 10:42AM s13 OTHER DIESEL VENT NO VACUUM ALARM CLEAR 4-26-23 10:42AM s12 OTHER DIESEL PRODUCT NO VACUUM ALARM CLEAR 4-26-23 10:42AM s13 OTHER DIESEL VENT NO VACUUM ALARM ALARM 4-26-23 10:42AM s12 OTHER DIESEL PRODUCT NO VACUUM ALARM ALARM 4-26-23 10:42AM s13 OTHER DIESEL VENT HIGH LIQUID ALARM ALARM 4-26-23 10:41AM s12 OTHER DIESEL PRODUCT HIGH LIQUID ALARM ALARM 4-26-23 10:41AM I11200 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK DIESEL DELIVERY NEEDED CLEAR 4-22-23 7:32PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 4-21-23 11:31AM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:22PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:22PM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:22PM SYSTEM PAPER OUT CLEAR 4-13-23 8:22PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:21PM SYSTEM PAPER OUT ALARM 4-13-23 8:21PM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:21PM SYSTEM PAPER OUT CLEAR 4-13-23 8:21PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:21PM SYSTEM PAPER OUT ALARM 4-13-23 8:21PM SYSTEM PRINTER ERROR CLEAR 4-13-23 8:21PM SYSTEM PAPER OUT CLEAR 4-13-23 8:21PM SYSTEM PRINTER ERROR ALARM 4-13-23 8:20PM SYSTEM PAPER OUT ALARM 4-13-23 8:20PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 4-12-23 11:49AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 4-12-23 9:21AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 3-28-23 6:41PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 3-27-23 5:54PM T 3 TANK 91 PREMIUM DELIVERY NEEDED CLEAR 3-26-23 2:52AM T 3 TANK 91 PREMIUM DELIVERY NEEDED ALARM 3-25-23 11:58PM T 3 TANK 91 PREMIUM DELIVERY NEEDED CLEAR 3-20-23 1:01AM T 3 TANK 91 PREMIUM DELIVERY NEEDED ALARM 3-19-23 4:30PM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 2-23-23 1:48PM T 4 TANK DIESEL LOW TEMP WARNING ALARM 2-23-23 1:47PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 2-23-23 1:03PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 2-23-23 12:54PM T 4 TANK DIESEL HIGH WATER WARNING CLEAR 2-23-23 12:47PM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 2-23-23 12:46PM T 4 TANK DIESEL LOW TEMP WARNING ALARM 2-23-23 12:44PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:34PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:30PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:30PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:28PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:26PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:25PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:23PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:23PM T 4 TANK DIESEL HIGH WATER WARNING ALARM 2-23-23 12:19PM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-23-23 12:17PM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 2-23-23 12:16PM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 2-23-23 12:13PM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 2-23-23 12:13PM T 4 TANK DIESEL HIGH WATER WARNING CLEAR 2-23-23 12:05PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 2-23-23 12:01PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 2-23-23 11:59AM T 4 TANK DIESEL HIGH WATER WARNING ALARM 2-23-23 11:57AM T 4 TANK DIESEL HIGH WATER WARNING CLEAR 2-23-23 11:57AM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 2-23-23 11:53AM I20600 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 TANK ALARM HISTORY TANK 1 87-1 UNLEADED OVERFILL ALARM DEC 29, 2022 12:20 PM DEC 29, 2022 12:17 PM AUG 29, 2022 1:41 AM HIGH PRODUCT ALARM AUG 15, 2022 2:05 PM PROBE OUT AUG 15, 2022 2:06 PM AUG 15, 2022 2:03 PM AUG 15, 2022 2:00 PM TANK 2 87-2 UNLEADED OVERFILL ALARM MAR 26, 2023 2:52 AM MAR 11, 2023 12:23 AM DEC 22, 2022 6:01 PM HIGH PRODUCT ALARM AUG 15, 2022 2:03 PM JUN 10, 2022 9:12 AM APR 9, 2022 5:54 AM PROBE OUT AUG 15, 2022 2:04 PM AUG 15, 2022 1:53 PM MAX PRODUCT ALARM JUN 10, 2022 9:12 AM APR 9, 2022 5:56 AM LOW TEMP WARNING AUG 15, 2022 2:04 PM TANK 3 91 PREMIUM OVERFILL ALARM AUG 15, 2022 2:02 PM LOW PRODUCT ALARM DEC 18, 2022 9:40 PM HIGH PRODUCT ALARM JUN 10, 2022 9:13 AM JUN 10, 2022 8:05 AM JUN 10, 2022 7:54 AM INVALID FUEL LEVEL DEC 18, 2022 7:44 PM PROBE OUT FEB 23, 2023 1:49 PM FEB 23, 2023 12:48 PM FEB 23, 2023 12:21 PM DELIVERY NEEDED MAR 25, 2023 11:58 PM MAR 19, 2023 4:30 PM FEB 8, 2023 4:22 PM MAX PRODUCT ALARM JUN 10, 2022 9:13 AM JUN 10, 2022 8:05 AM JUN 10, 2022 7:54 AM TANK 4 DIESEL HIGH WATER ALARM FEB 23, 2023 12:19 PM FEB 23, 2023 11:57 AM FEB 22, 2023 6:00 PM OVERFILL ALARM FEB 23, 2023 12:13 PM AUG 15, 2022 2:00 PM HIGH PRODUCT ALARM FEB 23, 2023 12:13 PM JUN 10, 2022 9:14 AM JUN 10, 2022 8:07 AM INVALID FUEL LEVEL FEB 23, 2023 12:30 PM FEB 23, 2023 12:28 PM FEB 23, 2023 12:25 PM PROBE OUT FEB 23, 2023 1:44 PM FEB 23, 2023 1:01 PM FEB 23, 2023 12:54 PM HIGH WATER WARNING FEB 23, 2023 12:19 PM FEB 23, 2023 11:57 AM FEB 22, 2023 6:00 PM DELIVERY NEEDED APR 21, 2023 11:31 AM APR 12, 2023 9:21 AM MAR 27, 2023 5:54 PM MAX PRODUCT ALARM FEB 23, 2023 12:13 PM JUN 10, 2022 9:14 AM JUN 10, 2022 8:07 AM LOW TEMP WARNING FEB 23, 2023 1:47 PM FEB 23, 2023 12:44 PM FEB 23, 2023 11:53 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:87 UNLEADED APR 26, 2023 11:39 AM PLLD SHUTDOWN ALARM APR 26, 2023 11:22 AM PLLD SHUTDOWN ALARM APR 26, 2023 11:22 AM GROSS LINE FAIL APR 26, 2023 11:02 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:23 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:16 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:14 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:12 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:10 AM PLLD SHUTDOWN ALARM APR 26, 2023 9:56 AM PLLD SHUTDOWN ALARM Q 2:91 PREMIUM APR 26, 2023 11:39 AM PLLD SHUTDOWN ALARM APR 26, 2023 11:15 AM PLLD SHUTDOWN ALARM APR 26, 2023 11:15 AM GROSS LINE FAIL APR 26, 2023 11:02 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:23 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:16 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:14 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:12 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:10 AM PLLD SHUTDOWN ALARM APR 26, 2023 9:57 AM PLLD SHUTDOWN ALARM Q 3:DIESEL APR 26, 2023 11:39 AM PLLD SHUTDOWN ALARM APR 26, 2023 11:10 AM PLLD SHUTDOWN ALARM APR 26, 2023 11:10 AM GROSS LINE FAIL APR 26, 2023 11:02 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:24 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:16 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:14 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:12 AM PLLD SHUTDOWN ALARM APR 26, 2023 10:10 AM PLLD SHUTDOWN ALARM APR 26, 2023 9:58 AM PLLD SHUTDOWN ALARM I30200 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87-1 STP APR 26, 2023 10:36 AM LOW LIQUID ALARM APR 26, 2023 10:23 AM SENSOR OUT ALARM APR 26, 2023 9:58 AM LOW LIQUID ALARM 2 87-1 FILL APR 26, 2023 10:24 AM SENSOR OUT ALARM APR 26, 2023 10:05 AM LOW LIQUID ALARM APR 26, 2023 10:00 AM FUEL ALARM 3 87-2 STP APR 26, 2023 10:23 AM SENSOR OUT ALARM APR 26, 2023 9:59 AM LOW LIQUID ALARM APR 26, 2023 9:56 AM FUEL ALARM 4 87-2 FILL APR 26, 2023 10:23 AM SENSOR OUT ALARM APR 26, 2023 10:05 AM LOW LIQUID ALARM APR 26, 2023 10:01 AM FUEL ALARM 5 91 STP APR 26, 2023 10:23 AM SENSOR OUT ALARM APR 26, 2023 9:59 AM LOW LIQUID ALARM APR 26, 2023 9:57 AM FUEL ALARM 6 91 FILL APR 26, 2023 10:23 AM SENSOR OUT ALARM APR 26, 2023 10:06 AM LOW LIQUID ALARM APR 26, 2023 10:03 AM FUEL ALARM 7 DIESEL STP APR 26, 2023 10:24 AM SENSOR OUT ALARM APR 26, 2023 9:59 AM LOW LIQUID ALARM APR 26, 2023 9:58 AM FUEL ALARM 8 DIESEL FILL APR 26, 2023 10:24 AM SENSOR OUT ALARM APR 26, 2023 10:08 AM LOW LIQUID ALARM APR 26, 2023 10:04 AM FUEL ALARM 9 DISP 1-2 APR 26, 2023 10:24 AM SENSOR OUT ALARM APR 26, 2023 10:17 AM LOW LIQUID ALARM APR 26, 2023 10:10 AM FUEL ALARM 10 DISP 3-4 APR 26, 2023 11:39 AM FUEL ALARM APR 26, 2023 11:02 AM FUEL ALARM APR 26, 2023 10:24 AM SENSOR OUT ALARM 11 DISP 5-6 APR 26, 2023 10:24 AM SENSOR OUT ALARM APR 26, 2023 10:18 AM LOW LIQUID ALARM APR 26, 2023 10:16 AM FUEL ALARM 12 DISP 7-8 APR 26, 2023 10:24 AM SENSOR OUT ALARM APR 26, 2023 10:18 AM LOW LIQUID ALARM APR 26, 2023 10:14 AM FUEL ALARM 13 VENT BOX APR 26, 2023 10:23 AM SENSOR OUT ALARM APR 26, 2023 10:19 AM LOW LIQUID ALARM APR 26, 2023 10:19 AM FUEL ALARM I31600 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87-1 PRODUCT APR 26, 2023 10:37 AM NO VACUUM ALARM APR 26, 2023 10:37 AM HIGH LIQUID ALARM APR 27, 2022 11:55 AM HIGH LIQUID ALARM 2 87-1 VENT APR 26, 2023 10:37 AM NO VACUUM ALARM APR 26, 2023 10:37 AM HIGH LIQUID ALARM APR 27, 2022 11:55 AM HIGH LIQUID ALARM 3 87-1 TANK APR 26, 2023 10:48 AM HIGH LIQUID ALARM APR 26, 2023 10:48 AM NO VACUUM ALARM APR 27, 2022 1:57 PM HIGH LIQUID ALARM 4 87-2 PRODUCT APR 26, 2023 10:39 AM NO VACUUM ALARM APR 26, 2023 10:38 AM HIGH LIQUID ALARM APR 27, 2022 12:06 PM HIGH LIQUID ALARM 5 87-2 VENT APR 26, 2023 10:39 AM NO VACUUM ALARM APR 26, 2023 10:38 AM HIGH LIQUID ALARM APR 27, 2022 12:06 PM HIGH LIQUID ALARM 6 87-2 TANK APR 26, 2023 10:47 AM NO VACUUM ALARM APR 27, 2022 1:20 PM HIGH LIQUID ALARM APR 27, 2022 1:20 PM NO VACUUM ALARM 7 87-2 VAPOR APR 26, 2023 10:39 AM NO VACUUM ALARM APR 26, 2023 10:38 AM HIGH LIQUID ALARM APR 27, 2022 12:06 PM HIGH LIQUID ALARM 8 ATM 9 91 PRODUCT APR 26, 2023 10:40 AM NO VACUUM ALARM APR 26, 2023 10:40 AM HIGH LIQUID ALARM APR 27, 2022 11:49 AM HIGH LIQUID ALARM 10 91 VENT APR 26, 2023 10:40 AM NO VACUUM ALARM APR 26, 2023 10:40 AM HIGH LIQUID ALARM APR 27, 2022 11:49 AM HIGH LIQUID ALARM 11 91 TANK APR 26, 2023 10:45 AM HIGH LIQUID ALARM APR 26, 2023 10:45 AM NO VACUUM ALARM APR 17, 2023 9:40 AM NO VACUUM ALARM 12 DIESEL PRODUCT APR 26, 2023 10:42 AM NO VACUUM ALARM APR 26, 2023 10:41 AM HIGH LIQUID ALARM APR 27, 2022 11:51 AM HIGH LIQUID ALARM 13 DIESEL VENT APR 26, 2023 10:42 AM NO VACUUM ALARM APR 26, 2023 10:41 AM HIGH LIQUID ALARM APR 27, 2022 11:51 AM HIGH LIQUID ALARM 14 DIESEL TANK APR 26, 2023 10:43 AM HIGH LIQUID ALARM APR 26, 2023 10:43 AM NO VACUUM ALARM APR 27, 2022 1:21 PM HIGH LIQUID ALARM 17 DISP 1-2 FM 18 DISP 3-4 FM 19 DISP 5-6 FM 20 DISP 7-8 FM 21 DISP 1-2 PRES SENSR I40200 APR 26, 2023 12:05 PM I40300 APR 26, 2023 12:05 PM I34200 APR 26, 2023 12:05 PM I34700 APR 26, 2023 12:05 PM IV0100 APR 26, 2023 12:05 PM 3351 HOWARDS 3200 PANAMA LN BAKERSFIELD CA 93313 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-01-19 10:09:13 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.38 23-01-18 10:09:19 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.49 23-01-11 10:08:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.81 23-01-04 10:08:21 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.74 22-12-28 10:08:05 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.11 22-12-21 10:09:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.55 22-12-14 10:09:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.28 22-12-07 10:09:17 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.66 22-11-30 10:10:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.41 22-11-29 10:09:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.45 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-10-18 10:10:20 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.02 19-12-18 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 19-11-25 10:02:24 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 19-11-12 10:03:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.45 19-02-14 10:02:00 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 18-03-22 10:01:18 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 17-12-11 10:01:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.98 17-03-20 10:03:18 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.61 16-07-31 08:43:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.95 16-06-04 10:02:17 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-04-26 10:23:20 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-04-26 10:23:20 ISD STARTUP 23-04-26 10:22:57 ISD SHUTDOWN 23-03-12 03:00:00 TIME CHANGE DETECTED AT: 23-03-12 02:00:13 23-03-03 10:10:08 READINESS ISD:PP EVR:PP ISD & EVR READY 23-03-02 16:21:36 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-03-02 16:21:36 ISD STARTUP 23-03-02 16:21:34 ISD SHUTDOWN 23-01-19 13:11:04 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 23-01-11 12:16:35 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED