Loading...
HomeMy WebLinkAbout2023 FMC and OPI Repair1 Jennifer Pruitt Subject:SA002, AT&T Probe Certification - PO-28045493 w/Overfill Test (BKFDCA01), Bakersfield Location:1520 20TH ST, BAKERSFIELD, CA 93301-4406 Start:Mon 4/3/2023 9:00 AM End:Mon 4/3/2023 11:00 AM Recurrence:(none) Meeting Status:Meeting organizer Organizer:Simplex Communication Required Attendees:AGUILAR, ADOLFO; MEDINA, ELOISA; 'FLORES, CECILIA'; AT&T CA Testing; 'HAYN, CINDY H (ATTSI)' (ch1921@att.com) ; Carlos Cardenas; Jennifer Pruitt; Maria Figueroa; Krystine Gossett; Alan Throckmorton; Randy Novak; Kristin Reynolds; Erin Langford; Jon Larsen Categories:Probe Certification, Overfill Alarm Testing, Legacy T Site There is an AT&T Probe Certification scheduled for this location on the date and time indicated. NOTE: -PO- 28045493 (Tait) will be addressed at this time. -Recertify the new probe -Testing will include the Overfill Test of the Overfill alarm -Permit Required for repairs made -Permit # TBD SA002 1520 20TH ST BAKERSFIELD 93301-4406   Please contact the Compliance Manager with any questions and/or comments at:  simplexcommunication@tait.com    714.560.8200    Environmental Health/CUPA Contact Information:   Bakersfield City Fire Department  2101 H Street  Bakersfield, CA 93301  Method of Notification: Email  Contact (Once Permit is Approved):  https://www.bakersfieldcity.us/1048/Inspection‐Request    Test Results Submittal: USTResults@bakersfieldfire.us    1 Jennifer Pruitt From:Luke Preece <lpreece@bakersfieldfire.us> Sent:Friday, March 17, 2023 4:13 PM To:Carlos Cardenas Subject:RE: New Fire Inspection Request (SA002 - Bakersfield) External Email.    Carlos,    You are confirmed for 4/3 @ 9am.    Thank you,                       From: WebMaster <WebMaster@bakersfieldcity.us>   Sent: Friday, March 10, 2023 5:24 PM  To: InspectionRequest <InspectionRequest@bakersfieldfire.us>  Subject: New Fire Inspection Request  Importance: Low    There is a new Fire Inspection Request.    Carlos Cardenas    (909) 230‐8256    ccardenas@tait.com    1520 20th St, Bakersfield, CA, 93301, USA    1520    Underground_Storage_Tank      We will be recertifying the new probe and also performing the overfill prevention test of the overfill alarm.      Luke Preece Fire Prevention/Environmental Officer Bakersfield Fire Department email: lpreece@bakersfieldfire.us web: www.bakersfieldfire.us phone: 661-326-3659 Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 04/03/2023 Pacific Bell Telephone Co. dba AT&T California 1520 20th St.Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Jon Larsen 588098 8144945 05/03/2024 VeederRoot B41757 03/04/2025 04/03/2023 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications?܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid?܆܆܆܆ Are the audible and visual alarms operational?܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational?܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment?܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed?܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational?܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational?܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS 350 Plus 120.00 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated?܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected?܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test?܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements?܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 ✔ Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults?܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational?܆܆ ܆܆ ܆܆ Was accuracy of system’s product level readings tested?܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested?܆܆ ܆܆ ܆܆ Were all probes reinstalled properly?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ✔ ✔ ✔ ✔ ✔ ✔ T-1 846397-105 / 590391 SA002U001 ATG Probe ✔ Certify ATG Probe only. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 03/29/2023 Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 4/3/2023 Pacific Bell Telephone Co. dba AT&T California 1520 20th St. Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Jon Larsen 588098 8144945 05/03/2024 VeederRoot B41757 03/04/2025 Manufacture Guidelines SA002U001 ATG Probe 4/3/2023 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. SA002U001 790091-001 ✔ ✔ ✔ 69.2" 90% ✔ ✔ I50301 APR 4, 2023 6:49 AM # 1:BKFDCA01 SA002 T-S I50302 APR 4, 2023 6:49 AM # 2:1520 20TH ST I50303 APR 4, 2023 6:49 AM # 3:BAKERSFIELD,CA 93301 I50304 APR 4, 2023 6:49 AM # 4:661-869-1846 I51700 APR 4, 2023 6:49 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 APR 4, 2023 6:49 AM MON DD YYYY HH:MM:SS xM I10200 APR 4, 2023 6:49 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162295 162126 2 INTERSTITIAL BD 201439 200914 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 RELAY BOARD 14933 14932 10 COMBO I/O BOARD 9929 9936 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 FAXMODEM BOARD 40571 40561 COMM 2 UNUSED 15000000 15000000 COMM 3 UNUSED 15000000 15000000 COMM 4 UNUSED 15000000 15000000 COMM 5 UNUSED 15000000 15000000 COMM 6 UNUSED 15000000 15000000 I60100 APR 4, 2023 6:49 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA002U001 ON 2 DIESEL TK#SA002A002 ON 3 OFF 4 OFF I60200 APR 4, 2023 6:49 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 2 DIESEL TK#SA002A002 3 4 I60300 APR 4, 2023 6:49 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 1 2 DIESEL TK#SA002A002 1 3 3 4 4 I60400 APR 4, 2023 6:49 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I60700 APR 4, 2023 6:49 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 82.00 2 DIESEL TK#SA002A002 30.00 3 0.00 4 0.00 I60900 APR 4, 2023 6:50 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 0.000450 2 DIESEL TK#SA002A002 0.000450 3 0.000000 4 0.000000 I61200 APR 4, 2023 6:50 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL MANIFOLDED TANKS 1 DIESEL TK#SA002U001 NONE 2 DIESEL TK#SA002A002 NONE 3 NONE 4 NONE I62100 APR 4, 2023 6:50 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 105 3 0 4 0 I62200 APR 4, 2023 6:50 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7601 2 DIESEL TK#SA002A002 237 3 0 4 0 I62300 APR 4, 2023 6:50 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7201 2 DIESEL TK#SA002A002 225 3 0 4 0 I62400 APR 4, 2023 6:50 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 2.0 2 DIESEL TK#SA002A002 2.0 I62800 APR 4, 2023 6:50 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I62900 APR 4, 2023 6:50 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 125 3 0 4 0 I70300 APR 4, 2023 6:50 AM LIQUID TYPE SENSOR LOCATION TYPE 1 FILL SUMP TRI-STATE (SINGLE FLOAT) 2 PIPING SUMP TRI-STATE (SINGLE FLOAT) 3 DAYTANK RUPTURE BASN TRI-STATE (SINGLE FLOAT) 4 DAY TANK ANNULAR TRI-STATE (SINGLE FLOAT) 5 ANNULAR UST TRI-STATE (SINGLE FLOAT) 6 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 7 REMOTE PUMP CABINET TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 APR 4, 2023 6:50 AM SOFTWARE REVISION LEVEL VERSION 120.00 SOFTWARE# 346120-100-A CREATED - 00.07.28.15.33 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 APR 4, 2023 6:50 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM CLEAR 4-03-23 9:10AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 4-03-23 9:10AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 4-03-23 9:09AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM ALARM 4-03-23 9:06AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 4-03-23 9:03AM T 1 TANK DIESEL TK#SA002U001 MAX PRODUCT ALARM CLEAR 4-03-23 9:02AM T 1 TANK DIESEL TK#SA002U001 MAX PRODUCT ALARM ALARM 4-03-23 9:01AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 4-03-23 9:01AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 4-03-23 9:01AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 4-03-23 8:59AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 4-03-23 8:59AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 4-03-23 8:58AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 4-03-23 8:57AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 4-03-23 8:57AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 3-15-23 9:58AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 3-15-23 9:54AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 3-15-23 9:50AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 3-15-23 9:49AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM CLEAR 3-15-23 9:45AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 3-15-23 9:45AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 3-15-23 9:44AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM ALARM 3-15-23 9:41AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 3-15-23 9:34AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 3-15-23 9:32AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 3-15-23 9:20AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 3-15-23 9:19AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 3-15-23 9:03AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM CLEAR 1-09-23 10:04AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM ALARM 1-09-23 10:04AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM CLEAR 1-09-23 9:33AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM ALARM 1-09-23 9:33AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM CLEAR 1-09-23 9:32AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM ALARM 1-09-23 9:32AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-09-23 9:22AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-09-23 9:14AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-09-23 9:13AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-09-23 9:13AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-09-23 9:13AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-09-23 9:09AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-09-23 9:09AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-09-23 9:08AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-09-23 9:03AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-09-23 9:02AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 12-23-22 4:19AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 12-23-22 3:45AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 12-23-22 3:41AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 12-23-22 3:39AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 12-23-22 2:24AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 12-23-22 2:08AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 12-23-22 2:08AM I11200 APR 4, 2023 6:51 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING CLEAR 4-03-23 9:11AM T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING ALARM 4-03-23 9:10AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 4-03-23 9:10AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 4-03-23 9:06AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 4-03-23 9:02AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 4-03-23 9:01AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 4-03-23 8:59AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 4-03-23 8:57AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 3-15-23 9:50AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 3-15-23 9:49AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 3-15-23 9:45AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 3-15-23 9:41AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 3-15-23 9:20AM T 1 TANK DIESEL TK#SA002U001 INVALID FUEL LEVEL CLEAR 3-15-23 9:19AM T 1 TANK DIESEL TK#SA002U001 INVALID FUEL LEVEL ALARM 12-23-22 4:19AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 12-23-22 4:19AM T 1 TANK DIESEL TK#SA002U001 INVALID FUEL LEVEL CLEAR 12-23-22 3:45AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 12-23-22 3:45AM T 1 TANK DIESEL TK#SA002U001 INVALID FUEL LEVEL ALARM 12-23-22 3:42AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 12-23-22 3:41AM T 1 TANK DIESEL TK#SA002U001 INVALID FUEL LEVEL CLEAR 12-23-22 3:39AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 12-23-22 3:39AM T 1 TANK DIESEL TK#SA002U001 INVALID FUEL LEVEL ALARM 12-23-22 2:25AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 12-23-22 2:24AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 12-23-22 2:08AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 12-23-22 2:08AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 12-22-22 5:50PM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 12-22-22 5:50PM SYSTEM PRINTER ERROR CLEAR 12-02-22 5:58PM SYSTEM PAPER OUT CLEAR 12-02-22 5:58PM SYSTEM PAPER OUT ALARM 12-02-22 5:58PM SYSTEM PAPER OUT CLEAR 12-02-22 5:58PM SYSTEM PAPER OUT ALARM 12-02-22 5:58PM SYSTEM PAPER OUT CLEAR 12-02-22 5:58PM SYSTEM PAPER OUT ALARM 12-02-22 5:58PM SYSTEM PAPER OUT CLEAR 12-02-22 5:58PM SYSTEM PAPER OUT ALARM 12-02-22 5:58PM SYSTEM PRINTER ERROR ALARM 12-02-22 5:58PM SYSTEM PRINTER ERROR CLEAR 11-14-22 7:56PM SYSTEM PRINTER ERROR ALARM 11-14-22 7:56PM T 2 TANK DIESEL TK#SA002A002 HIGH WATER WARNING CLEAR 10-28-22 10:33AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER WARNING ALARM 10-28-22 10:13AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-28-22 10:10AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-28-22 10:03AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 10-28-22 9:34AM T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING CLEAR 10-28-22 9:33AM T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING ALARM 10-28-22 9:32AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 10-28-22 9:25AM T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING CLEAR 1-27-22 12:13PM T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING ALARM 1-27-22 12:12PM I20600 APR 4, 2023 6:52 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 TANK ALARM HISTORY TANK 1 DIESEL TK#SA002U001 LEAK ALARM OCT 11, 2011 6:08 AM OCT 14, 2010 2:44 PM OCT 13, 2010 11:06 AM HIGH WATER ALARM APR 3, 2023 9:06 AM MAR 15, 2023 9:41 AM OCT 28, 2022 9:25 AM OVERFILL ALARM APR 3, 2023 9:01 AM APR 3, 2023 8:59 AM MAR 15, 2023 9:32 AM LOW PRODUCT ALARM APR 3, 2023 8:57 AM MAR 15, 2023 9:49 AM DEC 23, 2022 4:19 AM SUDDEN LOSS ALARM APR 4, 2010 3:43 PM FEB 19, 2010 10:08 AM FEB 19, 2010 10:05 AM HIGH PRODUCT ALARM APR 3, 2023 9:01 AM OCT 29, 2021 9:12 AM OCT 15, 2020 9:12 AM INVALID FUEL LEVEL DEC 23, 2022 4:19 AM DEC 23, 2022 3:42 AM DEC 23, 2022 2:25 AM PROBE OUT APR 3, 2023 9:09 AM APR 3, 2023 8:57 AM MAR 15, 2023 9:54 AM HIGH WATER WARNING APR 3, 2023 9:06 AM MAR 15, 2023 9:41 AM OCT 28, 2022 9:25 AM DELIVERY NEEDED APR 3, 2023 8:57 AM MAR 15, 2023 9:49 AM DEC 23, 2022 4:19 AM MAX PRODUCT ALARM APR 3, 2023 9:01 AM OCT 15, 2020 9:12 AM OCT 23, 2019 9:13 AM CSLD INCR RATE WARN DEC 10, 2008 9:38 AM SEP 18, 2008 10:06 AM SEP 18, 2008 6:58 AM LOW TEMP WARNING APR 3, 2023 9:10 AM OCT 28, 2022 9:32 AM JAN 27, 2022 12:12 PM TANK 2 DIESEL TK#SA002A002 SETUP DATA WARNING JAN 27, 2012 11:49 AM HIGH WATER ALARM OCT 28, 2022 10:13 AM OCT 29, 2021 9:40 AM NOV 21, 2016 10:37 AM OVERFILL ALARM OCT 23, 2019 10:26 AM NOV 2, 2018 10:38 AM NOV 21, 2016 11:18 AM LOW PRODUCT ALARM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM JAN 7, 2014 9:54 AM SUDDEN LOSS ALARM OCT 12, 2010 8:39 PM FEB 19, 2010 9:55 AM APR 28, 2009 11:13 AM HIGH PRODUCT ALARM OCT 28, 2022 10:03 AM OCT 29, 2021 9:35 AM OCT 29, 2021 9:33 AM INVALID FUEL LEVEL OCT 29, 2021 9:33 AM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM PROBE OUT OCT 28, 2022 10:32 AM OCT 28, 2022 10:01 AM OCT 29, 2021 9:42 AM HIGH WATER WARNING OCT 28, 2022 10:13 AM OCT 29, 2021 9:40 AM NOV 21, 2016 10:37 AM DELIVERY NEEDED OCT 23, 2019 10:24 AM NOV 2, 2018 10:37 AM NOV 7, 2017 1:37 PM MAX PRODUCT ALARM OCT 28, 2022 10:03 AM OCT 29, 2021 9:35 AM OCT 29, 2021 9:33 AM LOW TEMP WARNING DEC 17, 2014 11:26 AM JAN 22, 2013 10:14 AM I30200 APR 4, 2023 6:53 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 FILL SUMP OCT 28, 2022 9:09 AM FUEL ALARM JAN 27, 2022 12:07 PM FUEL ALARM JAN 1, 2022 8:19 AM SETUP DATA WARNING 2 PIPING SUMP OCT 28, 2022 9:15 AM FUEL ALARM OCT 29, 2021 8:37 AM FUEL ALARM OCT 25, 2021 5:05 PM FUEL ALARM 3 DAYTANK RUPTURE BASN JAN 9, 2023 10:04 AM FUEL ALARM JAN 9, 2023 9:33 AM FUEL ALARM OCT 28, 2022 9:57 AM FUEL ALARM 4 DAY TANK ANNULAR JAN 9, 2023 9:32 AM FUEL ALARM OCT 28, 2022 9:59 AM FUEL ALARM OCT 28, 2022 9:58 AM FUEL ALARM 5 ANNULAR UST OCT 28, 2022 9:05 AM FUEL ALARM OCT 29, 2021 8:40 AM FUEL ALARM OCT 15, 2020 9:00 AM FUEL ALARM 6 TRANSITION SUMP OCT 28, 2022 9:37 AM FUEL ALARM OCT 16, 2022 4:47 PM FUEL ALARM OCT 29, 2021 9:01 AM FUEL ALARM 7 REMOTE PUMP CABINET OCT 28, 2022 9:41 AM FUEL ALARM OCT 25, 2022 8:40 AM SENSOR OUT ALARM OCT 25, 2022 8:36 AM SENSOR OUT ALARM Identification of Inspection Procedures for Overfill Prevention Equipment To Whom It May Concern: Tait Environmental Services, Inc., utilizes the following procedures when conducting Overfill Prevention Equipment Inspections: 1) Drop Tubes with Overfill Prevention Valves a) Verify information based upon Manufacturer installation instructions and follow their inspection procedures. b) If manufacturer information is not available, we conduct the inspection per PEI-RP1200-17, Section 7.1 2) Audible/Visual Alarms a) Verify programming or installation per manufacturer guidelines and test the system per manufacturer specifications. b) If manufacturer information is not available, we conduct the inspection per PEI-1200-17, Section 7.3. 3) Ballfloat Inspections are conducted following the procedures in PEI-RP1200-17, Section 7.2