Loading...
HomeMy WebLinkAbout2023 SB989 Appendix VII Underground Storage Tank Secondary Containment Testing Report Form CERS = California Environmental Reporting System, ICC = International Code Council, ID = Identification, NA = Not Applicable, UDC = Under-Dispenser Containment, Page 1 of 5 TYPE OF ACTION ☐ Installation ☐ Repair ☐ 6 Month X 36 Month CERS ID 10489972 Test Date 6/2/2023 Facility Name Obie's Downtown Shell (North) Facility Address 2317 L St. (North) City Bakersfield ZIP Code 93301 Company Performing the Test Advanced Compliance Phone 6617064321 Mailing Address 4007 Brae Burn Dr Bakersfield Ca 93306 Service Technician Performing Test Bradley Hinsley Contractor/Tank Tester License Number 971259 ICC Number 8373948 ICC Expiration Date 8/9/2023 Manufacturer and Test Equipment Training Certifications Expiration Date ICC Service Techican 8/9/2023 INCON STS 10/5/2023 Test Procedures Used Components Tested PEI/RP1200-19 Sect. 4. Tank Annular PEI/RP1200-19 Sect. 5. Line Secondary PEI/RP1200-19 Sect. 6. Containment Sump I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 6/2/2023 Total # of Pages 1. FACILITY INFORMATION 2. SERVICE TECHNICIAN INFORMATION 3. TRAINING AND CERTIFICATIONS 4. TEST PROCEDURE INFORMATION 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 2 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure X Vacuum ☐ Hydrostatic Test Equipment Used: Tank Annular Testing Setup Tank ID 91/Diesel 87S/87M Tank Manufacturer Unknown Unknown Tank Capacity 20,073 20,073 Test Start Time 10:35 08:45 Initial Reading -10.00 InHg -10.00 InHg Test End Time 12:35 10:45 Final Reading -7.00 InHg -10.00 InHg Change in Reading 3.0 InHg 0.0 InHg Pass/Fail Criteria +/- 0.0 InHg +/- 0.0 InHg Tightness Test Results ☐ Pass X Fail X Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type X Pressure ☐ Vacuum ☐ Hydrostatic Test Equipment Used: Piping Secondary Testing Setup Pipe Run ID 87S 15-20 87S 13-18 87M 15-20 87M 13-18 Pipe Manufacturer Unknown Unknown Unknown Unknown Test Start Time 08:10 12:50 08:55 09:20 Initial Reading 5.0 PSI 5.0 PSI 5.0 PSI 5.0 PSI Test End Time 09:10 13:50 09:55 10:20 Final Reading 5.0 PSI 5.0 PSI 5.0 PSI 0.0 PSI Change in Reading 0.0 PSI 0.0 PSI 0.0 PSI 5.0 PSI Pass/Fail Criteria +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass X Fail Pipe Run ID Diesel 15-20 Diesel 13-18 91 15-20 91 13-18 Pipe Manufacturer Unknown Unknown Unknown Unknown Test Start Time 07:50 08:00 08:40 13:10 Initial Reading 5.0 PSI 5.0 PSI 5.0 PSI 5.0 PSI Test End Time 08:50 09:00 09:40 14:10 Final Reading 5.0 PSI 5.0 PSI 0.0 PSI 5.0 PSI Change in Reading 0.0 PSI 0.0 PSI 5.0 PSI 0.0 PSI Pass/Fail Criteria +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail ☐ Pass X Fail X Pass ☐ Fail Additional copies of this page may be attached. 6. TANK SECONDARY CONTAINMENT TEST 7. PIPE SECONDARY CONTAINMENT TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 3 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: Incon STS Sump/UDC ID 87S STP 87M STP 91 STP Diesel STP Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 36 36 36 36 Sump Bottom to Top of Highest Pipe Penetration (inches) 17 17 17 17 Test Start Time Visual 08:38 Visual Visual Initial Reading Failure 5.6928 Failure Failure Test End Time Torn 08:53 Torn Torn Final Reading Sump 4.9754 Sump Sump Change in Reading Penetration 0.7174 Penetration Penetration Pass/Fail Criteria +/- 0.0020 Tightness Test Results ☐ Pass X Fail ☐ Pass X Fail ☐ Pass X Fail ☐ Pass X Fail Sump/UDC ID UDC 13/14 UDC 15/16 UDC 17/18 UDC 19/20 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 30 30 30 30 Sump Bottom to Top of Highest Pipe Penetration (inches) 16 16 16 16 Test Start Time 11:59 09:55 11:59 09:55 Initial Reading 6.5229 2.0262 5.0075 4.2991 Test End Time 12:14 10:10 12:14 10:10 Final Reading 6.5213 1.4739 4.9893 4.1144 Change in Reading 0.0016 0.5523 0.0182 0.1847 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail ☐ Pass X Fail ☐ Pass X Fail ☐ Pass X Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 4 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: Incon STS Sump/UDC ID 91 Fill Sump Manufacturer Unknown Sump Depth (inches) 50 Sump Bottom to Top of Highest Pipe Penetration (inches) 14 Test Start Time Sump Initial Reading Did Test End Time Not Final Reading Hold Change in Reading Water Pass/Fail Criteria Tightness Test Results ☐ Pass X Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST (continued) Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 5 of 5 Could hear hissing in Diesel STP when pulling vacuum on annular. 91 15-20 and 87M 13-18 Lines failed due to bad boots. 9. COMMENTS