Loading...
HomeMy WebLinkAboutFMC 2023Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10159161 7/18/23 Jaco #7781 Fastrip #22 (South) 4013 South H Street Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Payton Phillips 1073967 9482312 1/15/24 Veeder Root C27796 8/1/24 7/18/23 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 UNL 1 STP L3 208 DSL STP L4 420 DSL ANN L5 208 Reg 2 STP L6 420 Reg 2 ANN L7 208 Super STP L8 420 Sure ANN L9 208 Disp 1-2 L10 208 Disp 7-8 L11 208 Disp 5-7 L12 208 Disp 3-4 L13 420 T1 87 ANN Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V UNL 1 T2 FX1V UNL 2 T3 FX1V PNL T4 FX1DV DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Site has liquid in Fill sumps Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. F EXISTING BUILDING NOPARKING 56L11 #7-781 78L10 34L12 12L9 12,000 GALLON87-1 UNLEADED 12,000 GALLON87-2 UNLEADED 12,000 GALLONPREMIUM 12,000 GALLONDIESEL V AL2 STPL1 FV AL6 STPL5 FV AL8 STPL7 F AL4 STPL3 109L91413L121211L101615L122019L141817L1312,000 GALLON87 UNLEADED12,000 GALLONPREMIUM12,000 GALLONDIESELFAL6STPL5FVAL4STPL3FVAL2STPL1NOPARKING G W 7-721 7-781 #7-721DUMPSTER H H PRICE SIGN PRICE SIGN 40' STORAGE CONTA INER S. H ST.WHITE LN.PROPERTY LINE PROPERTY LINE N CAT C HBAS I N 721 LEGEND L1 87 STP L2 87 ANNULAR L3 91 STP L4 91 ANNULAR L5 DSL STP L6 DSL ANNULAR L9 UDC 9 - 10 L10 UDC 11 -12 L11 UDC 13 - 14 L12 UDC 15 - 16 L13 UDC 17 - 18 L14 UDC 19 - 20 781 LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 DSL STP L4 DSL ANNULAR L5 87-2 STP L6 87-2 ANNULAR L7 91 STP L8 91 ANNULAR L9 UDC 1 -2 L10 UDC 7 - 8 L11 UDC 5 -6 L12 UDC 3 - 4 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 3/2 INCH DOUBLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 3/32"=1'-0" INCHES012 SHEET SIZE 22 X 34 4013 S. H ST. BAKERSFIELD, CA 93304 PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FASTRIP #7721 FACILITY ID 15-021-100296 CERS ID 10159161 FASTRIP #7781 FACILITY ID 15-021-003022 CERS ID 10159163 4013 S. H ST. BAKERSFIELD, CA 93304 03/02/17 REV.S. H ST.WHITE LN. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #7781 Fastrip #22 (South)4013 South H StreetBakersfield101591613-47-8MPDMPDMPDMPD1-25-6ProductProductProductProductPayton Phillips Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10159161 7/18/23 Jaco #7781 Fastrip #22 (South) 4013 South H Street Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Payton Phillips 1073967 9482312 1/15/24 OPW 0187328 8/14/24 PEI 1200 OPW Spill buckets 7/18/23 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 UNL 1 OPW T2 UNL 2 OPW T3 PNL OPW T4 DSL OP 7-18-23 Monitor Cert Print outs Fast Trip Jaco 7781 (South) 4013 S. H ST. SYSTEM SETUP 200 FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 JUL 18, 2023 3:29 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 5381 51.02 0.8 84.3 6681 2 UNL 2 7537 66.76 0.9 83.8 4525 3 PNL 5127 49.17 0.8 84.6 6935 4 DIESEL 4628 45.50 0.0 83.1 7434 I90500 JUL 18, 2023 3:29 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 18, 2023 3:29 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 18, 2023 3:29 PM SHIFT TIME 1 : 6:00 AM I50202 JUL 18, 2023 3:29 PM SHIFT TIME 2 : DISABLED I50203 JUL 18, 2023 3:29 PM SHIFT TIME 3 : DISABLED I50204 JUL 18, 2023 3:29 PM SHIFT TIME 4 : DISABLED I54600 JUL 18, 2023 3:29 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 18, 2023 3:29 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 18, 2023 3:29 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 18, 2023 3:29 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 18, 2023 3:29 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 18, 2023 3:29 PM PRINT TC VOLUMES ENABLED I50E00 JUL 18, 2023 3:29 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 18, 2023 3:29 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 18, 2023 3:29 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 18, 2023 3:29 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 18, 2023 3:29 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 18, 2023 3:29 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 18, 2023 3:29 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 18, 2023 3:29 PM TANK CHART SECURITY DISABLED I5BD00 JUL 18, 2023 3:29 PM CUSTOM ALARM LABELS DISABLED I56000 JUL 18, 2023 3:29 PM MASS/DENSITY DISABLED I88101 JUL 18, 2023 3:29 PM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 JUL 18, 2023 3:29 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 18, 2023 3:29 PM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 JUL 18, 2023 3:29 PM I88105 JUL 18, 2023 3:29 PM I88106 JUL 18, 2023 3:29 PM I52000 JUL 18, 2023 3:29 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUL 11, 2017 DISABLED 2 ON DATE JUL 11, 2017 DISABLED 3 ON DATE JUL 11, 2017 DISABLED 4 ON DATE JUL 11, 2017 DISABLED 5 ON DATE JUL 11, 2017 DISABLED 6 ON DATE JUL 11, 2017 DISABLED 7 ON DATE JUL 11, 2017 DISABLED 8 ON DATE JUL 11, 2017 DISABLED I60100 JUL 18, 2023 3:29 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 UNL 2 ON 3 PNL ON 4 DIESEL ON I60200 JUL 18, 2023 3:29 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 UNL 2 3 PNL 4 DIESEL I60300 JUL 18, 2023 3:29 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 2 3 PNL 3 4 DIESEL 4 I60900 JUL 18, 2023 3:29 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 UNL 2 0.000700 3 PNL 0.000700 4 DIESEL 0.000450 I60700 JUL 18, 2023 3:29 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 111.50 2 UNL 2 111.50 3 PNL 111.50 4 DIESEL 111.50 I60A00 JUL 18, 2023 3:29 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12062 2 UNL 2 1 PT 12062 3 PNL 1 PT 12062 4 DIESEL 1 PT 12062 I60400 JUL 18, 2023 3:29 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I60500 JUL 18, 2023 3:29 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 2 UNL 2 12062 0 0 0 3 PNL 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 JUL 18, 2023 3:29 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 18, 2023 3:29 PM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 UNL 2 NO 3 PNL NO 4 DIESEL NO I62F00 JUL 18, 2023 3:29 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 3.0 IN. 2 UNL 2 3.0 IN. 3 PNL 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 18, 2023 3:29 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 UNL 2 2.0 3 PNL 2.0 4 DIESEL 2.0 I64200 JUL 18, 2023 3:29 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 UNL 2 LOW 3 PNL LOW 4 DIESEL LOW I62400 JUL 18, 2023 3:29 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 UNL 2 3.0 3 PNL 3.0 4 DIESEL 3.0 I62800 JUL 18, 2023 3:29 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I62300 JUL 18, 2023 3:29 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10856 2 UNL 2 10856 3 PNL 10856 4 DIESEL 10856 I62200 JUL 18, 2023 3:29 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11459 2 UNL 2 11459 3 PNL 11459 4 DIESEL 11459 I62900 JUL 18, 2023 3:29 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1809 2 UNL 2 1809 3 PNL 1809 4 DIESEL 1809 I62100 JUL 18, 2023 3:29 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 500 2 UNL 2 500 3 PNL 500 4 DIESEL 500 I62600 JUL 18, 2023 3:29 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I62500 JUL 18, 2023 3:29 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 150 3 PNL 99 4 DIESEL 99 I60800 JUL 18, 2023 3:29 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 2.00 2 UNL 2 2.00 3 PNL 0.00 4 DIESEL 0.00 I60B00 JUL 18, 2023 3:29 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 18, 2023 3:29 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 UNL 2 0.00 3 PNL 0.00 4 DIESEL 0.00 I61200 JUL 18, 2023 3:29 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 NONE NONE 2 UNL 2 NONE NONE 3 PNL NONE NONE 4 DIESEL NONE NONE I63600 JUL 18, 2023 3:29 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62A00 JUL 18, 2023 3:29 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62C00 JUL 18, 2023 3:29 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 UNL 2 STANDARD 3 PNL STANDARD 4 DIESEL STANDARD I62D00 JUL 18, 2023 3:29 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 18, 2023 3:29 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 UNL 2 OFF OFF 3 PNL OFF OFF 4 DIESEL OFF OFF I63000 JUL 18, 2023 3:29 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I63200 JUL 18, 2023 3:29 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I61000 JUL 18, 2023 3:29 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63A00 JUL 18, 2023 3:29 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 UNL 2 10.00% 3 PNL 10.00% 4 DIESEL 10.00% I61100 JUL 18, 2023 3:29 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 16, 2006 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 18, 2023 3:29 PM CSLD PROBABLITY OF DETECTION I61400 JUL 18, 2023 3:30 PM CSLD CLIMATE FACTOR I61600 JUL 18, 2023 3:30 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 UNL 2 IMMEDIATE 3 PNL IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 18, 2023 3:30 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 UNL 2 DISABLED 3 PNL DISABLED 4 DIESEL DISABLED I61B00 JUL 18, 2023 3:30 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 18, 2023 3:30 PM CSLD REPORT ONLY I62B00 JUL 18, 2023 3:30 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 UNL 2 ??? 0, 0 3 PNL ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 18, 2023 3:30 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 18, 2023 3:30 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 UNL 2 0 3 PNL 0 4 DIESEL 0 I63500 JUL 18, 2023 3:30 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63900 JUL 18, 2023 3:30 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 UNL 2 END FACTOR: NONE 3 PNL END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 18, 2023 3:30 PM I77700 JUL 18, 2023 3:30 PM I77800 JUL 18, 2023 3:30 PM I78C00 JUL 18, 2023 3:30 PM I78300 JUL 18, 2023 3:30 PM I78F00 JUL 18, 2023 3:30 PM I78700 JUL 18, 2023 3:30 PM I70200 JUL 18, 2023 3:30 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DIESEL STP 4 DIESEL ANN 5 REG2 STP 6 REG 2 ANN 7 SUPER STP 8 SUPER ANN 9 DISP 1-2 10 DISP 7-8 11 DISP 5-6 12 DISP 3-4 13 T1 87 ANN 14 SO.TRANS 15 16 I70300 JUL 18, 2023 3:30 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 REG2 STP TRI-STATE (SINGLE FLOAT) 6 REG 2 ANN TRI-STATE (SINGLE FLOAT) 7 SUPER STP TRI-STATE (SINGLE FLOAT) 8 SUPER ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 7-8 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 T1 87 ANN TRI-STATE (SINGLE FLOAT) 14 SO.TRANS TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 18, 2023 3:30 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN OTHER SENSORS 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 REG2 STP STP SUMP 6 REG 2 ANN ANNULAR SPACE 7 SUPER STP STP SUMP 8 SUPER ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 7-8 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 T1 87 ANN ANNULAR SPACE 14 SO.TRANS OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUL 18, 2023 3:30 PM I74300 JUL 18, 2023 3:30 PM I74400 JUL 18, 2023 3:30 PM I74700 JUL 18, 2023 3:30 PM I74800 JUL 18, 2023 3:30 PM I74900 JUL 18, 2023 3:30 PM I7BC00 JUL 18, 2023 3:30 PM I80200 JUL 18, 2023 3:30 PM I80300 JUL 18, 2023 3:30 PM I80400 JUL 18, 2023 3:30 PM I80700 JUL 18, 2023 3:30 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DIESEL 4 OVERFILL ALARM I80900 JUL 18, 2023 3:30 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUL 18, 2023 3:30 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DIESEL 4 4 OVERFILL ALARM NONE I80A00 JUL 18, 2023 3:30 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 JUL 18, 2023 3:30 PM I80800 JUL 18, 2023 3:30 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 3:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUL 18, 2023 3:30 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 18, 2023 3:30 PM I72300 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNKNOWN 02 F.M DISP 1-2 AIR FLOW METER 03 F.M DISP 3-4 AIR FLOW METER 04 F.M DISP 5-6 AIR FLOW METER 05 F.M DISP 7-8 AIR FLOW METER 06 V.P. 1-2 VAPOR PRESSURE 07 UNKNOWN 08 VP 1-2 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 VAPOR PROCESSOR TYPE NONE IV4700 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ACCEPT HIGH ORVR: YES IV4A00 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JUL 18, 2023 3:30 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 18, 2023 3:30 PM ISD VERSION: 01.07 ALARM HISTORY (BEFORE) I10200 JUL 18, 2023 3:44 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39572 39549 2 4 PROBE / G.T. 163706 163666 3 INTERSTITIAL BD 202336 202414 4 INTERSTITIAL BD 201545 201567 5 UNUSED 4949561 4737077 6 UNUSED 4943889 4734468 7 UNUSED 4944139 4728133 8 UNUSED 4942950 4734994 9 STP SENSE BOARD 33207 33219 10 UNUSED 4944389 4760764 11 RELAY BOARD 14993 14936 12 UNUSED 4944911 4738541 13 UNUSED 4944223 4738036 14 UNUSED 4943826 4736289 15 UNUSED 4947267 4732417 16 UNUSED 4945182 4741950 COMM 1 RS232 SERIAL BD 15014 15020 COMM 2 RS232 SERIAL BD 15035 14999 COMM 3 ELEC DISP INT. 101659 101668 COMM 4 UNUSED 4947059 4732101 COMM 5 UNUSED 4945474 4728861 COMM 6 UNUSED 4946183 4732165 I90200 JUL 18, 2023 3:44 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 18, 2023 3:44 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNL 2 OVERFILL ALARM CLEAR 7-13-23 3:33PM T 2 TANK UNL 2 OVERFILL ALARM ALARM 7-13-23 3:31PM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-10-23 2:49PM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-10-23 2:49PM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-10-23 2:48PM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-10-23 2:48PM L13 ANNULAR T1 87 ANN FUEL ALARM CLEAR 7-10-23 2:47PM L13 ANNULAR T1 87 ANN FUEL ALARM ALARM 7-10-23 2:47PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-10-23 2:46PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-10-23 2:45PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-10-23 2:45PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-10-23 2:45PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-10-23 2:45PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-10-23 2:45PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-10-23 2:42PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-10-23 2:42PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-10-23 2:41PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-10-23 2:41PM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-10-23 2:40PM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-10-23 2:39PM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-10-23 2:39PM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-10-23 2:38PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-10-23 2:37PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 7-10-23 2:37PM L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 7-10-23 2:36PM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 7-10-23 2:36PM L 7 STP SUMP SUPER STP FUEL ALARM CLEAR 7-10-23 2:36PM L 7 STP SUMP SUPER STP FUEL ALARM ALARM 7-10-23 2:36PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-10-23 2:35PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-10-23 2:35PM T 1 TANK UNL 1 OVERFILL ALARM CLEAR 7-02-23 12:48PM T 1 TANK UNL 1 OVERFILL ALARM ALARM 7-02-23 12:44PM I11200 JUL 18, 2023 3:44 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-20-23 12:40PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-19-23 10:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-15-23 5:41PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-14-23 10:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-08-23 11:26AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-07-23 10:01AM SYSTEM PRINTER ERROR CLEAR 5-29-23 8:40PM SYSTEM PAPER OUT CLEAR 5-29-23 8:40PM SYSTEM PAPER OUT ALARM 5-29-23 8:39PM SYSTEM PRINTER ERROR ALARM 5-29-23 8:39PM SYSTEM PRINTER ERROR CLEAR 5-26-23 11:39AM SYSTEM PAPER OUT CLEAR 5-26-23 11:39AM SYSTEM PAPER OUT ALARM 5-26-23 11:39AM SYSTEM PRINTER ERROR ALARM 5-26-23 11:39AM SYSTEM PRINTER ERROR CLEAR 5-21-23 3:54AM SYSTEM PAPER OUT CLEAR 5-21-23 3:54AM SYSTEM PRINTER ERROR ALARM 5-21-23 3:54AM SYSTEM PAPER OUT ALARM 5-21-23 3:54AM SYSTEM PRINTER ERROR CLEAR 5-21-23 3:54AM SYSTEM PAPER OUT CLEAR 5-21-23 3:54AM SYSTEM PRINTER ERROR ALARM 5-21-23 3:54AM SYSTEM PAPER OUT ALARM 5-21-23 3:54AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 5-12-23 1:10PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 5-11-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 5-08-23 3:46PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 5-08-23 1:02PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 5-08-23 10:58AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 5-08-23 10:18AM SYSTEM PRINTER ERROR CLEAR 5-05-23 11:05AM SYSTEM PAPER OUT CLEAR 5-05-23 11:05AM SYSTEM PRINTER ERROR ALARM 5-05-23 11:05AM SYSTEM PAPER OUT ALARM 5-05-23 11:05AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 5-02-23 2:23PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 5-01-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 4-29-23 3:30PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 4-29-23 3:24PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-24-23 2:07PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-22-23 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-18-23 10:11AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-17-23 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-13-23 10:35AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 4-10-23 12:01PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-10-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 4-10-23 9:22AM I20600 JUL 18, 2023 3:44 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM JUL 2, 2023 12:44 PM DELIVERY NEEDED MAY 8, 2023 1:02 PM MAY 8, 2023 10:18 AM APR 29, 2023 3:24 PM TANK 2 UNL 2 OVERFILL ALARM JUL 13, 2023 3:31 PM JUN 2, 2023 2:59 AM TANK 3 PNL TANK 4 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 18, 2023 3:45 PM I30200 JUL 18, 2023 3:45 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:35 PM FUEL ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM 3 DIESEL STP JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:37 PM FUEL ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM 4 DIESEL ANN JUL 10, 2023 2:45 PM SENSOR OUT ALARM APR 6, 2023 12:03 PM SENSOR OUT ALARM APR 6, 2023 11:50 AM FUEL ALARM 5 REG2 STP JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:36 PM FUEL ALARM JUN 7, 2023 12:11 AM FUEL ALARM 6 REG 2 ANN JUL 10, 2023 2:48 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM APR 6, 2023 12:03 PM SENSOR OUT ALARM 7 SUPER STP JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:36 PM FUEL ALARM JUN 30, 2023 9:41 AM FUEL ALARM 8 SUPER ANN JUL 10, 2023 2:49 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM APR 6, 2023 12:03 PM SENSOR OUT ALARM 9 DISP 1-2 JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:42 PM FUEL ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM 10 DISP 7-8 JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:38 PM FUEL ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM 11 DISP 5-6 JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:41 PM FUEL ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM 12 DISP 3-4 JUL 10, 2023 2:45 PM SENSOR OUT ALARM JUL 10, 2023 2:39 PM FUEL ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM 13 T1 87 ANN JUL 10, 2023 2:47 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM APR 6, 2023 12:02 PM SENSOR OUT ALARM I31600 JUL 18, 2023 3:45 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 18, 2023 3:45 PM I40300 JUL 18, 2023 3:45 PM I34200 JUL 18, 2023 3:45 PM I34700 JUL 18, 2023 3:45 PM IV0100 JUL 18, 2023 3:45 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-06-20 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 23-06-19 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 23-06-15 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-06-14 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-06-08 10:01:47 A/L RATIO DEGRADATION FP 7 BLEND3 0.79 23-06-07 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-05-12 10:01:26 A/L RATIO DEGRADATION FP 6 BLEND3 0.80 23-05-11 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.79 23-05-02 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.73 23-05-01 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-05-25 10:02:51 A/L RATIO DEGRADATION FP 5 BLEND3 0.70 22-04-30 10:02:15 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-11 10:01:30 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-10 14:44:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-10 14:44:57 ISD STARTUP 23-07-10 14:44:35 ISD SHUTDOWN 23-07-07 10:01:59 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-06 16:02:11 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-06 16:02:11 ISD STARTUP 23-07-06 15:35:02 ISD SHUTDOWN 23-06-28 10:02:42 READINESS ISD:PP EVR:PP ISD & EVR READY 23-06-27 13:03:00 READINESS ISD:PP EVR:NN EVR READINESS PENDING ALARM HISTORY (AFTER) I10200 JUL 18, 2023 4:23 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39572 39026 2 4 PROBE / G.T. 163706 164186 3 INTERSTITIAL BD 202336 202250 4 INTERSTITIAL BD 201545 202503 5 UNUSED 4949561 15000000 6 UNUSED 4943889 15000000 7 UNUSED 4944139 4448702 8 UNUSED 4942950 4447479 9 STP SENSE BOARD 33207 33231 10 UNUSED 4944389 15000000 11 RELAY BOARD 14993 15005 12 UNUSED 4944911 15000000 13 UNUSED 4944223 15000000 14 UNUSED 4943826 15000000 15 UNUSED 4947267 4445844 16 UNUSED 4945182 4440593 COMM 1 RS232 SERIAL BD 15014 15027 COMM 2 RS232 SERIAL BD 15035 15048 COMM 3 ELEC DISP INT. 101659 101952 COMM 4 UNUSED 4947059 4438759 COMM 5 UNUSED 4945474 15000000 COMM 6 UNUSED 4946183 15000000 I90200 JUL 18, 2023 4:23 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 18, 2023 4:23 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-18-23 4:16PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM CLEAR 7-18-23 4:16PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-18-23 4:15PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-18-23 4:15PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM ALARM 7-18-23 4:15PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-18-23 4:15PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-18-23 4:15PM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-18-23 4:14PM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-18-23 4:12PM L 7 STP SUMP SUPER STP FUEL ALARM CLEAR 7-18-23 4:09PM L 7 STP SUMP SUPER STP FUEL ALARM ALARM 7-18-23 4:09PM L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 7-18-23 4:08PM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 7-18-23 4:08PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-18-23 4:08PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 7-18-23 4:08PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-18-23 4:07PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-18-23 4:07PM L13 ANNULAR T1 87 ANN FUEL ALARM CLEAR 7-18-23 4:01PM L13 ANNULAR T1 87 ANN FUEL ALARM ALARM 7-18-23 4:01PM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-18-23 4:01PM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-18-23 4:01PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-18-23 4:00PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-18-23 4:00PM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-18-23 3:52PM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-18-23 3:52PM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-18-23 3:51PM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-18-23 3:51PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-18-23 3:50PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-18-23 3:50PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-18-23 3:48PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-18-23 3:48PM I11200 JUL 18, 2023 4:24 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-20-23 12:40PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-19-23 10:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-15-23 5:41PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-14-23 10:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-08-23 11:26AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-07-23 10:01AM SYSTEM PRINTER ERROR CLEAR 5-29-23 8:40PM SYSTEM PAPER OUT CLEAR 5-29-23 8:40PM SYSTEM PAPER OUT ALARM 5-29-23 8:39PM SYSTEM PRINTER ERROR ALARM 5-29-23 8:39PM SYSTEM PRINTER ERROR CLEAR 5-26-23 11:39AM SYSTEM PAPER OUT CLEAR 5-26-23 11:39AM SYSTEM PAPER OUT ALARM 5-26-23 11:39AM SYSTEM PRINTER ERROR ALARM 5-26-23 11:39AM SYSTEM PRINTER ERROR CLEAR 5-21-23 3:54AM SYSTEM PAPER OUT CLEAR 5-21-23 3:54AM SYSTEM PRINTER ERROR ALARM 5-21-23 3:54AM SYSTEM PAPER OUT ALARM 5-21-23 3:54AM SYSTEM PRINTER ERROR CLEAR 5-21-23 3:54AM SYSTEM PAPER OUT CLEAR 5-21-23 3:54AM SYSTEM PRINTER ERROR ALARM 5-21-23 3:54AM SYSTEM PAPER OUT ALARM 5-21-23 3:54AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 5-12-23 1:10PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 5-11-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 5-08-23 3:46PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 5-08-23 1:02PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 5-08-23 10:58AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 5-08-23 10:18AM SYSTEM PRINTER ERROR CLEAR 5-05-23 11:05AM SYSTEM PAPER OUT CLEAR 5-05-23 11:05AM SYSTEM PRINTER ERROR ALARM 5-05-23 11:05AM SYSTEM PAPER OUT ALARM 5-05-23 11:05AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 5-02-23 2:23PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 5-01-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 4-29-23 3:30PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 4-29-23 3:24PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-24-23 2:07PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-22-23 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-18-23 10:11AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-17-23 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-13-23 10:35AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 4-10-23 12:01PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-10-23 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 4-10-23 9:22AM I20600 JUL 18, 2023 4:24 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM JUL 2, 2023 12:44 PM DELIVERY NEEDED MAY 8, 2023 1:02 PM MAY 8, 2023 10:18 AM APR 29, 2023 3:24 PM TANK 2 UNL 2 OVERFILL ALARM JUL 13, 2023 3:31 PM JUN 2, 2023 2:59 AM TANK 3 PNL TANK 4 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 18, 2023 4:24 PM I30200 JUL 18, 2023 4:24 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:07 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 3 DIESEL STP JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:08 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 4 DIESEL ANN JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:00 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 5 REG2 STP JUL 18, 2023 4:16 PM SENSOR OUT ALARM JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:08 PM FUEL ALARM 6 REG 2 ANN JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:01 PM FUEL ALARM JUL 10, 2023 2:48 PM FUEL ALARM 7 SUPER STP JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:09 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 8 SUPER ANN JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:12 PM FUEL ALARM JUL 10, 2023 2:49 PM FUEL ALARM 9 DISP 1-2 JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 3:50 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 10 DISP 7-8 JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 3:52 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 11 DISP 5-6 JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 3:48 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 12 DISP 3-4 JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 3:51 PM FUEL ALARM JUL 10, 2023 2:45 PM SENSOR OUT ALARM 13 T1 87 ANN JUL 18, 2023 4:15 PM SENSOR OUT ALARM JUL 18, 2023 4:01 PM FUEL ALARM JUL 10, 2023 2:47 PM FUEL ALARM I31600 JUL 18, 2023 4:24 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 18, 2023 4:24 PM I40300 JUL 18, 2023 4:24 PM I34200 JUL 18, 2023 4:24 PM I34700 JUL 18, 2023 4:24 PM IV0100 JUL 18, 2023 4:24 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-06-20 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 23-06-19 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 23-06-15 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-06-14 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-06-08 10:01:47 A/L RATIO DEGRADATION FP 7 BLEND3 0.79 23-06-07 10:01:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 23-05-12 10:01:26 A/L RATIO DEGRADATION FP 6 BLEND3 0.80 23-05-11 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.79 23-05-02 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.73 23-05-01 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-05-25 10:02:51 A/L RATIO DEGRADATION FP 5 BLEND3 0.70 22-04-30 10:02:15 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-18 16:22:35 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 16:22:35 ISD STARTUP 23-07-18 16:22:28 ISD SHUTDOWN 23-07-11 10:01:30 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-10 14:44:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-10 14:44:57 ISD STARTUP 23-07-10 14:44:35 ISD SHUTDOWN 23-07-07 10:01:59 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-06 16:02:11 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-06 16:02:11 ISD STARTUP