Loading...
HomeMy WebLinkAboutFMC 2023Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10137943 07/25/23 Jaco #3366 Fastrip (West) 8001 White Lane Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/25 Vaporless Manufacturing LLC 03/14/25 OPW-1193585 04/14/25 07/25/23 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 420 87-1 ANNULAR L2 208 87-1 FILL SUMP L3 208 87-1 STP L4 420 87-2 ANNULAR L5 208 87-2 FILL SUMP L6 208 87-2 STP L7 420 91 ANNULAR L8 208 91 FILL SUMP L9 208 91 STP L10 420 DIESEL ANNULAR L11 208 DIESEL FILL SUMP L12 208 DIESEL STP L13 208 DISPENSER 1/2 L14 208 DISPENSER 3/4 L15 208 DISPENSER 5/6 L16 208 DISPENSER 7/8 L17 208 DISPENSER 9/10 L18 208 DISPENSER 11/12 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 UNLEADED T2 FX1V 91 PREMIUM T3 FX1DV DIESEL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 07/25/23 NO PARKINGNO PAR KING EXISTING BUILDING L13 L14 L15L16 L17 L18 L12STP L9STP L6STP L3STP L10 L7 L4 L1 L11 L8 L5 L2 87-2 UNLEADED 12,000 GALLON87-1 UNLEADED 12,000 GALLON DIESEL12,000 GALLON 1/2 43 65 910 78 12/11 #3-366 #3-367 N 91 PREMIUM12,000 GALLON V F 87-1 UNLEADED12,000 GALLON 87-2 UNLEADED12,000 GALLON91 PREMIUM12,000 GALLON DIESEL12,000 GALLON L5STP L2STP L11STP L14STP AL6 L1 L10 L13 L7/L8 L3 L12 L15 L9 L18 L17 L16L19 L20 L21 18/17 1516 1314 2122 1920 25/24 L22 PROPERTY LINE PROPERTY LINEH W W H PRICE SIGN PRICE SIGNDIESEL PRICE SIGN #367 #366 NO PARKINGACCESS RAMPS ACCESSRAMPDUMPSTER G A A A V F V F F A A A A A F F F F V V V 366 LEGEND L1 87-1 ANNULAR L2 87-1 FILL L3 87-1 STP L4 87-2 ANNULAR L5 87-2 FILL L6 87-2 STP L7 91 ANNULAR L8 91 FILL L9 91 STP L10 DSL ANNULAR L11 DSL FILL L12 DSL STP L13 UDC 1 - 2 L14 UDC 3 - 4 L15 UDC 5 - 6 L16 UDC 7 - 8 L17 UDC 9 - 10 L18 UDC 11 -12 367 LEGEND L1 87-1 ANNULAR L2 87-1 STP ANNULAR AND SUMP SENSOR 2-TO-1 L3 87-1 FILL L5 87-2 STP L6 87- 2 STP ANNULAR L7 87-2 FILL L8 87-2 ANNULAR FILL L9 87-2 ANNULAR L10 91 ANNULAR L11 91 STP L12 91 FILL L13 DSL ANNULAR L14 DSL STP L15 DSL FILL L16 UDC 13 - 14 L17 UDC 15 - 16 L18 UDC 17 - 18 L19 UDC 19 -20 L20 UDC 21 -22 L21 UDC 23 - 24 L22 VENT BOX ANNULAR AND SUMP SENSOR 2-TO-1 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3/2 INCH DOUBLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE S1: 87-2 UNLEADED VENT LINE S2: PRODUCT SIPHON LINE AND VACUUM CHASE S3: VAPOR RETURN LINE EMERGENCY SHUT-OFF OVERFILL ALARM PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR FIRE EXTINGUISHER WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM WH A F V SITE MAP DATE REVISIONS DATE: DRAWN BY: CHECKED: APPROVED: RAC CADFILE: SHEET NO. A.P.N.:385-013-21-4 SCALE: CONVENIENCE MARKET FOR: 3101 STATE RDBAKERSFIELD, CA 93308 PROJECT OWNER: DRAWING: CD FASTRIPS - 3-366-3-367 3366-MSP FASTRIP FOOD STORE BAKERSFIELD, CALIFORNIA 933098001 WHITE LN. JACO HILL SITE PLAN C1 TAB:CERS 1"=15'-0" INCHES012 SHEET SIZE 22 X 34 01/07/2022 8001 WHITE LN. BAKERSFIELD, CA 93309 GOSFORD RD. WHITE LN. PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-097250 CERS ID 10137946 FASTRIPS 3-366 / 3-367 8001 WHITE LN. BAKERSFIELD, CA 93309 02/12/2021 REV. VICINITY MAP PROJECT DATA APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #3366 Fastrip (West)8001 White LaneBakersfield101379433/47/8 11/12MPDMPDMPDMPDMPDMPD1/25/69/10ProductProductProductProductProductProductMark Fisher Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10137943 07/25/23 Jaco #3366 Fastrip (West) 8001 White Lane Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/25 OPW-1193585 04/14/25 PEI1200, 1 hour hydrostatic test All Spill Containers 07/25/23 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1: 87-1 OPW T2: 87-2 OPW T3: 91 OPW T4: DIESEL OPW System Setup Fastrip West (8001 White Lane) Responses Received: 200 FASTRIP 366 8001 WHITE LN BAKERSFIELD CA JUL 25, 2023 9:12 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 7566 66.67 1.5 82.6 4496 2 UNLEADED 2 7737 67.94 1.0 82.6 4325 3 PREMIUM 7640 67.22 0.0 82.7 4422 4 DIESEL 2698 30.54 1.2 82.6 9364 I90500 JUL 25, 2023 9:12 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 25, 2023 9:12 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 25, 2023 9:12 AM SHIFT TIME 1 : DISABLED I50202 JUL 25, 2023 9:12 AM SHIFT TIME 2 : DISABLED I50203 JUL 25, 2023 9:12 AM SHIFT TIME 3 : DISABLED I50204 JUL 25, 2023 9:12 AM SHIFT TIME 4 : DISABLED I54600 JUL 25, 2023 9:12 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 25, 2023 9:12 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 25, 2023 9:12 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 25, 2023 9:12 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 25, 2023 9:12 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 25, 2023 9:12 AM PRINT TC VOLUMES ENABLED I50E00 JUL 25, 2023 9:12 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 25, 2023 9:12 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 25, 2023 9:12 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 25, 2023 9:12 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 25, 2023 9:12 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 25, 2023 9:12 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 25, 2023 9:12 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 25, 2023 9:12 AM TANK CHART SECURITY DISABLED I5BD00 JUL 25, 2023 9:12 AM CUSTOM ALARM LABELS DISABLED I56000 JUL 25, 2023 9:12 AM MASS/DENSITY DISABLED I88101 JUL 25, 2023 9:12 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 25, 2023 9:12 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 25, 2023 9:12 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 25, 2023 9:12 AM I88105 JUL 25, 2023 9:12 AM I88106 JUL 25, 2023 9:12 AM I52000 JUL 25, 2023 9:12 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE FEB 23, 2012 DISABLED 2 ON DATE FEB 23, 2012 DISABLED 3 ON DATE FEB 23, 2012 DISABLED 4 ON DATE FEB 23, 2012 DISABLED 5 ON DATE FEB 23, 2012 DISABLED 6 ON DATE FEB 23, 2012 DISABLED 7 ON DATE FEB 23, 2012 DISABLED 8 ON DATE FEB 23, 2012 DISABLED I60100 JUL 25, 2023 9:12 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 UNLEADED 2 ON 3 PREMIUM ON 4 DIESEL ON I60200 JUL 25, 2023 9:13 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 UNLEADED 2 3 PREMIUM 4 DIESEL I60300 JUL 25, 2023 9:13 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 2 3 PREMIUM 3 4 DIESEL 4 I60900 JUL 25, 2023 9:13 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 UNLEADED 2 0.000700 3 PREMIUM 0.000700 4 DIESEL 0.000450 I60700 JUL 25, 2023 9:13 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.00 2 UNLEADED 2 111.00 3 PREMIUM 111.00 4 DIESEL 111.00 I60A00 JUL 25, 2023 9:13 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12062 2 UNLEADED 2 1 PT 12062 3 PREMIUM 1 PT 12062 4 DIESEL 1 PT 12062 I60400 JUL 25, 2023 9:13 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 UNLEADED 2 12062 3 PREMIUM 12062 4 DIESEL 12062 I60500 JUL 25, 2023 9:13 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 2 UNLEADED 2 12062 0 0 0 3 PREMIUM 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 JUL 25, 2023 9:13 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNLEADED 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 25, 2023 9:13 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 UNLEADED 2 NO 3 PREMIUM NO 4 DIESEL NO I62F00 JUL 25, 2023 9:13 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 UNLEADED 2 4.0 IN. 3 PREMIUM 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 25, 2023 9:13 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 UNLEADED 2 2.0 3 PREMIUM 2.0 4 DIESEL 2.0 I64200 JUL 25, 2023 9:13 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 UNLEADED 2 LOW 3 PREMIUM LOW 4 DIESEL LOW I62400 JUL 25, 2023 9:13 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 UNLEADED 2 3.0 3 PREMIUM 3.0 4 DIESEL 4.0 I62800 JUL 25, 2023 9:13 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 UNLEADED 2 12062 3 PREMIUM 12062 4 DIESEL 12062 I62300 JUL 25, 2023 9:13 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10856 2 UNLEADED 2 10856 3 PREMIUM 10856 4 DIESEL 10856 I62200 JUL 25, 2023 9:13 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11459 2 UNLEADED 2 11459 3 PREMIUM 11459 4 DIESEL 11459 I62900 JUL 25, 2023 9:13 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 482 2 UNLEADED 2 1800 3 PREMIUM 1689 4 DIESEL 1800 I62100 JUL 25, 2023 9:13 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 UNLEADED 2 500 3 PREMIUM 500 4 DIESEL 500 I62600 JUL 25, 2023 9:13 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I62500 JUL 25, 2023 9:13 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I60800 JUL 25, 2023 9:13 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I60B00 JUL 25, 2023 9:13 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 25, 2023 9:13 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I61200 JUL 25, 2023 9:13 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED 2 NONE 2 UNLEADED 2 1 NONE 3 PREMIUM NONE NONE 4 DIESEL NONE NONE I63600 JUL 25, 2023 9:13 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62A00 JUL 25, 2023 9:13 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62C00 JUL 25, 2023 9:13 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 UNLEADED 2 STANDARD 3 PREMIUM STANDARD 4 DIESEL STANDARD I62D00 JUL 25, 2023 9:13 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 25, 2023 9:13 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 UNLEADED 2 OFF OFF 3 PREMIUM OFF OFF 4 DIESEL OFF OFF I63000 JUL 25, 2023 9:13 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I63200 JUL 25, 2023 9:13 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I61000 JUL 25, 2023 9:13 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63A00 JUL 25, 2023 9:13 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 UNLEADED 2 10.00% 3 PREMIUM 10.00% 4 DIESEL 10.00% I61100 JUL 25, 2023 9:13 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 25, 2023 9:13 AM CSLD PROBABLITY OF DETECTION I61400 JUL 25, 2023 9:13 AM CSLD CLIMATE FACTOR I61600 JUL 25, 2023 9:13 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 UNLEADED 2 IMMEDIATE 3 PREMIUM IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 25, 2023 9:13 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 UNLEADED 2 DISABLED 3 PREMIUM DISABLED 4 DIESEL DISABLED I61B00 JUL 25, 2023 9:13 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 25, 2023 9:13 AM CSLD REPORT ONLY I62B00 JUL 25, 2023 9:13 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 UNLEADED 2 ??? 0, 0 3 PREMIUM ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 25, 2023 9:13 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 25, 2023 9:13 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 UNLEADED 2 0 3 PREMIUM 0 4 DIESEL 0 I63500 JUL 25, 2023 9:13 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63900 JUL 25, 2023 9:13 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 UNLEADED 2 END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 25, 2023 9:13 AM I77700 JUL 25, 2023 9:13 AM I77800 JUL 25, 2023 9:13 AM I78C00 JUL 25, 2023 9:13 AM I78300 JUL 25, 2023 9:13 AM I78F00 JUL 25, 2023 9:13 AM I78700 JUL 25, 2023 9:13 AM I70200 JUL 25, 2023 9:13 AM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 UNL FILL 3 UNL STP 4 UNL 2 ANN 5 UNLD 2 FILL 6 UNL 2 STP 7 PREM ANN 8 PREM FILL 9 PREM STP 10 DSL ANN 11 DSL FILL 12 DSL STP 13 DISP 1-2 14 DISP 3 4 15 DISP 5-6 16 DISP 7-8 17 DISP 9-10 18 DISP 11-12 19 20 21 22 23 24 I70300 JUL 25, 2023 9:13 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 UNL FILL TRI-STATE (SINGLE FLOAT) 3 UNL STP TRI-STATE (SINGLE FLOAT) 4 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 5 UNLD 2 FILL TRI-STATE (SINGLE FLOAT) 6 UNL 2 STP TRI-STATE (SINGLE FLOAT) 7 PREM ANN TRI-STATE (SINGLE FLOAT) 8 PREM FILL TRI-STATE (SINGLE FLOAT) 9 PREM STP TRI-STATE (SINGLE FLOAT) 10 DSL ANN TRI-STATE (SINGLE FLOAT) 11 DSL FILL TRI-STATE (SINGLE FLOAT) 12 DSL STP TRI-STATE (SINGLE FLOAT) 13 DISP 1-2 TRI-STATE (SINGLE FLOAT) 14 DISP 3 4 TRI-STATE (SINGLE FLOAT) 15 DISP 5-6 TRI-STATE (SINGLE FLOAT) 16 DISP 7-8 TRI-STATE (SINGLE FLOAT) 17 DISP 9-10 TRI-STATE (SINGLE FLOAT) 18 DISP 11-12 TRI-STATE (SINGLE FLOAT) 19 TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 JUL 25, 2023 9:13 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 UNL FILL PIPING SUMP 3 UNL STP STP SUMP 4 UNL 2 ANN ANNULAR SPACE 5 UNLD 2 FILL PIPING SUMP 6 UNL 2 STP STP SUMP 7 PREM ANN ANNULAR SPACE 8 PREM FILL PIPING SUMP 9 PREM STP STP SUMP 10 DSL ANN ANNULAR SPACE 11 DSL FILL PIPING SUMP 12 DSL STP STP SUMP 13 DISP 1-2 DISPENSER PAN 14 DISP 3 4 DISPENSER PAN 15 DISP 5-6 DISPENSER PAN 16 DISP 7-8 DISPENSER PAN 17 DISP 9-10 DISPENSER PAN 18 DISP 11-12 DISPENSER PAN 19 OTHER SENSORS 20 OTHER SENSORS 21 OTHER SENSORS 22 OTHER SENSORS 23 OTHER SENSORS 24 OTHER SENSORS I74200 JUL 25, 2023 9:13 AM I74300 JUL 25, 2023 9:13 AM I74400 JUL 25, 2023 9:13 AM I74700 JUL 25, 2023 9:13 AM I74800 JUL 25, 2023 9:13 AM I74900 JUL 25, 2023 9:13 AM I7BC00 JUL 25, 2023 9:13 AM I80200 JUL 25, 2023 9:13 AM I80300 JUL 25, 2023 9:13 AM I80400 JUL 25, 2023 9:13 AM I80700 JUL 25, 2023 9:13 AM RELAY LABEL DEVICE LABEL 1 SHUTDOWN 2 OVERFILL ALARM 3 INTERNAL ALARM 4 I80900 JUL 25, 2023 9:13 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 SHUTDOWN NORMALLY CLOSED 2 OVERFILL ALARM NORMALLY OPEN 3 INTERNAL ALARM NORMALLY OPEN 4 NORMALLY OPEN I80B00 JUL 25, 2023 9:13 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 SHUTDOWN 3 2 OVERFILL ALARM NONE 3 INTERNAL ALARM NONE 4 NONE I80A00 JUL 25, 2023 9:13 AM RELAY TYPE RELAY DESIGNATION TYPE 1 SHUTDOWN STANDARD 2 OVERFILL ALARM STANDARD 3 INTERNAL ALARM MOMENTARY 4 STANDARD I80C00 JUL 25, 2023 9:13 AM I80800 JUL 25, 2023 9:13 AM RELAY SETUP REPORT R 1:SHUTDOWN TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 3:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L 3:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L 3:SHORT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 3:INTERNAL ALARM TYPE: MOMENTARY NORMALLY OPEN IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:GROSS TEST FAIL ALL:PERIODIC TEST FAIL ALL:ANNUAL TEST FAIL ALL:PER TST NEEDED WRN ALL:ANN TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:ANN TST NEEDED ALM ALL:TANK TEST ACTIVE ALL:NO CSLD IDLE TIME ALL:TANK SIPHON BREAK ALL:LOW TEMP WARNING LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 JUL 25, 2023 9:14 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 25, 2023 9:14 AM I72300 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 11-12 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 9-10 AIR FLOW METER 07 FM 11-12 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA VAPOR PROCESSOR TYPE NONE IV4700 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ACCEPT HIGH ORVR: NO IV4A00 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 01 BLEND3 02 02 02 01 01 BLEND3 03 03 03 02 01 BLEND3 04 04 04 02 01 BLEND3 05 05 05 03 01 BLEND3 06 06 06 03 01 BLEND3 07 07 07 04 01 BLEND3 08 08 08 04 01 BLEND3 09 09 09 05 01 BLEND3 10 10 10 05 01 BLEND3 11 11 11 06 01 BLEND3 12 12 12 06 01 BLEND3 IV4B00 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx 09 05 02/09 03/09 09/09 xx/xx 10 05 02/10 03/10 09/10 xx/xx 11 06 02/11 03/11 09/11 xx/xx 12 06 02/12 03/12 09/12 xx/xx IV4900 JUL 25, 2023 9:14 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 25, 2023 9:14 AM ISD VERSION: 01.07 Fastrip West 8001 White Lane Alarm History (Before) Responses Received: I10200 JUL 25, 2023 9:16 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39395 39306 2 4 PROBE / G.T. 163529 163246 3 INTERSTITIAL BD 201924 201556 4 INTERSTITIAL BD 201901 201646 5 INTERSTITIAL BD 201060 200747 6 UNUSED 9661155 9539505 7 UNUSED 9644453 9537285 8 UNUSED 9643221 9534828 9 UNUSED 9638633 9528133 10 RELAY BOARD 14922 14899 11 UNUSED 9641842 9534557 12 UNUSED 9636678 9531798 13 UNUSED 9641927 9531367 14 UNUSED 9635913 9528996 15 UNUSED 9631239 9534341 16 UNUSED 9633619 9532250 COMM 1 ELEC DISP INT. 100982 101008 COMM 2 RS232 SERIAL BD 15007 14985 COMM 3 RS232 SERIAL BD 15007 14985 COMM 4 UNUSED 9648981 9540053 COMM 5 UNUSED 9632131 9531388 COMM 6 UNUSED 9631664 9535914 I90200 JUL 25, 2023 9:16 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 25, 2023 9:16 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNLEADED 2 OVERFILL ALARM CLEAR 7-21-23 11:11AM T 2 TANK UNLEADED 2 OVERFILL ALARM ALARM 7-21-23 11:09AM L13 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-18-23 10:41AM L13 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-18-23 10:41AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L16 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L10 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L15 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 8 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L12 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L14 DISP PAN DISP 3 4 SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L11 PIPE DSL FILL SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L13 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 3 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 2 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 9 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 7 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 6 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 5 PIPE UNLD 2 FILL SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-18-23 10:32AM L 3 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 8 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 7 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 6 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 2 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 5 PIPE UNLD 2 FILL SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-18-23 10:31AM L10 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-18-23 10:31AM L12 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-18-23 10:31AM L11 PIPE DSL FILL SENSOR OUT ALARM ALARM 7-18-23 10:31AM L16 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-18-23 10:31AM L15 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-18-23 10:31AM L 9 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-18-23 10:31AM L14 DISP PAN DISP 3 4 SENSOR OUT ALARM ALARM 7-18-23 10:31AM L13 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-18-23 10:31AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 7-18-23 10:31AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 7-18-23 10:31AM L10 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-18-23 10:24AM L10 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-18-23 10:19AM L10 ANNULAR DSL ANN FUEL ALARM CLEAR 7-18-23 10:19AM L 5 PIPE UNLD 2 FILL FUEL ALARM CLEAR 7-18-23 10:05AM L 5 PIPE UNLD 2 FILL FUEL ALARM ALARM 7-18-23 10:03AM L18 DISP PAN DISP 11-12 FUEL ALARM CLEAR 7-18-23 9:58AM L18 DISP PAN DISP 11-12 FUEL ALARM ALARM 7-18-23 9:58AM L17 DISP PAN DISP 9-10 FUEL ALARM CLEAR 7-18-23 9:56AM L17 DISP PAN DISP 9-10 FUEL ALARM ALARM 7-18-23 9:56AM L16 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-18-23 9:56AM I11200 JUL 25, 2023 9:16 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 7-25-23 9:11AM SYSTEM PRINTER ERROR ALARM 7-25-23 9:11AM SYSTEM PRINTER ERROR CLEAR 7-16-23 7:43PM SYSTEM PAPER OUT CLEAR 7-16-23 7:43PM SYSTEM PAPER OUT ALARM 7-16-23 7:43PM SYSTEM PRINTER ERROR ALARM 7-16-23 7:43PM SYSTEM PRINTER ERROR CLEAR 6-19-23 4:52AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:45AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:45AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:45AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:45AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:44AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:44AM SYSTEM PAPER OUT CLEAR 6-18-23 3:44AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:44AM SYSTEM PAPER OUT ALARM 6-18-23 3:44AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:44AM SYSTEM PAPER OUT CLEAR 6-18-23 3:44AM SYSTEM PRINTER ERROR ALARM 6-16-23 5:56PM SYSTEM PAPER OUT ALARM 6-16-23 5:56PM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 5-05-23 10:11AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 5-02-23 10:02AM OTHER ISD VAPOR LEAK WARN CLEAR 4-10-23 10:02AM SYSTEM PRINTER ERROR CLEAR 4-09-23 7:43PM SYSTEM PAPER OUT CLEAR 4-09-23 7:43PM SYSTEM PRINTER ERROR ALARM 4-09-23 7:38PM SYSTEM PAPER OUT ALARM 4-09-23 7:38PM OTHER ISD VAPOR LEAK WARN ALARM 4-09-23 10:02AM SYSTEM PRINTER ERROR CLEAR 4-09-23 8:01AM SYSTEM PAPER OUT CLEAR 4-09-23 8:01AM SYSTEM PRINTER ERROR ALARM 4-09-23 8:01AM SYSTEM PAPER OUT ALARM 4-09-23 8:01AM SYSTEM PRINTER ERROR CLEAR 4-09-23 8:00AM SYSTEM PAPER OUT CLEAR 4-09-23 8:00AM SYSTEM PRINTER ERROR ALARM 4-09-23 8:00AM SYSTEM PAPER OUT ALARM 4-09-23 8:00AM SYSTEM PRINTER ERROR CLEAR 4-09-23 8:00AM SYSTEM PAPER OUT CLEAR 4-09-23 8:00AM SYSTEM PRINTER ERROR ALARM 4-09-23 5:44AM SYSTEM PAPER OUT ALARM 4-09-23 5:44AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 4-07-23 5:08PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 4-07-23 10:02AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 4-05-23 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 4-04-23 10:02AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 3-31-23 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 3-24-23 10:02AM SYSTEM PRINTER ERROR CLEAR 3-11-23 11:23AM SYSTEM PAPER OUT CLEAR 3-11-23 11:23AM SYSTEM PRINTER ERROR ALARM 3-11-23 11:18AM SYSTEM PAPER OUT ALARM 3-11-23 11:18AM I20600 JUL 25, 2023 9:16 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUN 18, 2023 4:06 AM JUN 12, 2023 9:17 AM MAR 21, 2023 12:27 AM TANK 2 UNLEADED 2 OVERFILL ALARM JUL 21, 2023 11:09 AM JUL 16, 2023 10:00 AM JUL 7, 2023 11:57 AM TANK 3 PREMIUM OVERFILL ALARM NOV 5, 2022 2:16 AM TANK 4 DIESEL LOW PRODUCT ALARM FEB 13, 2021 8:05 AM DELIVERY NEEDED SEP 3, 2022 8:31 AM MAY 24, 2022 9:25 AM FEB 13, 2021 8:05 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 25, 2023 9:16 AM I30200 JUL 25, 2023 9:16 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:53 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 2 UNL FILL JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:45 AM FUEL ALARM JUN 16, 2023 6:34 AM FUEL ALARM 3 UNL STP JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:45 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 4 UNL 2 ANN JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:52 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 5 UNLD 2 FILL JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 10:03 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 6 UNL 2 STP JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:44 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 7 PREM ANN JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:50 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 8 PREM FILL JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:47 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 9 PREM STP JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:43 AM FUEL ALARM JUL 25, 2022 9:10 AM FUEL ALARM 10 DSL ANN JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 10:19 AM SENSOR OUT ALARM JUL 18, 2023 9:48 AM FUEL ALARM 11 DSL FILL JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:47 AM FUEL ALARM JUN 21, 2023 6:13 AM FUEL ALARM 12 DSL STP JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:42 AM FUEL ALARM JUL 16, 2023 6:46 PM FUEL ALARM 13 DISP 1-2 JUL 18, 2023 10:41 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:54 AM FUEL ALARM 14 DISP 3 4 JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:54 AM FUEL ALARM JUL 25, 2022 9:10 AM FUEL ALARM 15 DISP 5-6 JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:55 AM FUEL ALARM JUL 25, 2022 9:10 AM FUEL ALARM 16 DISP 7-8 JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:56 AM FUEL ALARM JUL 25, 2022 9:10 AM FUEL ALARM 17 DISP 9-10 JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:56 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM 18 DISP 11-12 JUL 18, 2023 10:31 AM SENSOR OUT ALARM JUL 18, 2023 9:58 AM FUEL ALARM JUL 25, 2022 9:10 AM SENSOR OUT ALARM I31600 JUL 25, 2023 9:17 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 11-12 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 JUL 20, 2022 5:02 PM COMMUNICATION ALARM JUL 20, 2022 3:11 PM COMMUNICATION ALARM JUL 20, 2022 12:29 PM COMMUNICATION ALARM 7 FM 11-12 I40200 JUL 25, 2023 9:17 AM I40300 JUL 25, 2023 9:17 AM I34200 JUL 25, 2023 9:17 AM I34700 JUL 25, 2023 9:17 AM IV0100 JUL 25, 2023 9:17 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-05-05 10:02:01 A/L RATIO DEGRADATION FP10 BLEND3 0.79 23-05-04 10:02:12 A/L RATIO DEGRADATION FP10 BLEND3 0.78 23-05-03 10:02:05 A/L RATIO DEGRADATION FP10 BLEND3 0.78 23-05-02 10:02:06 A/L RATIO DEGRADATION FP10 BLEND3 0.79 23-04-09 10:02:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.61 23-04-07 10:02:09 A/L RATIO DEGRADATION FP 3 BLEND3 0.77 23-04-04 10:02:13 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 23-03-30 10:02:14 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 23-03-29 10:02:15 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 23-03-28 10:02:26 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-31 10:02:22 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 22-08-06 10:01:53 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-08-03 10:01:09 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-13 10:01:35 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 21-04-19 10:02:18 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 20-10-23 10:01:58 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD 20-10-23 10:01:58 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD 20-10-17 10:02:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-06-14 10:01:09 A/L RATIO GROSS BLOCKAGE FP 9 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-19 10:02:31 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-18 10:33:36 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 10:33:36 ISD STARTUP 23-07-18 10:33:17 ISD SHUTDOWN 23-07-17 10:02:59 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-16 15:54:20 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-16 15:54:20 ISD STARTUP 23-07-16 15:53:51 ISD SHUTDOWN 23-05-05 10:11:01 COLLECTION TEST HH10 GRADE TEST MANUALLY CLEARED 23-04-07 17:08:09 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED After: Responses Received: I10200 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39395 39303 2 4 PROBE / G.T. 163529 162963 3 INTERSTITIAL BD 201924 201470 4 INTERSTITIAL BD 201901 201448 5 INTERSTITIAL BD 201060 200551 6 UNUSED 9661155 9553595 7 UNUSED 9644453 9552498 8 UNUSED 9643221 9545940 9 UNUSED 9638633 9545973 10 RELAY BOARD 14922 14892 11 UNUSED 9641842 9550316 12 UNUSED 9636678 9547629 13 UNUSED 9641927 9542360 14 UNUSED 9635913 9545844 15 UNUSED 9631239 9549091 16 UNUSED 9633619 9548768 COMM 1 ELEC DISP INT. 100982 100902 COMM 2 RS232 SERIAL BD 15007 14978 COMM 3 RS232 SERIAL BD 15007 14978 COMM 4 UNUSED 9648981 9553735 COMM 5 UNUSED 9632131 9547199 COMM 6 UNUSED 9631664 9548575 I90200 JUL 25, 2023 12:04 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L18 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 7-25-23 9:55AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 7-25-23 9:55AM L16 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L12 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L15 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L14 DISP PAN DISP 3 4 SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 9 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L11 PIPE DSL FILL SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L13 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 3 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L10 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 8 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 7 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 6 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 2 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 5 PIPE UNLD 2 FILL SENSOR OUT ALARM CLEAR 7-25-23 9:54AM L 3 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 8 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 7 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 2 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 6 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 5 PIPE UNLD 2 FILL SENSOR OUT ALARM ALARM 7-25-23 9:53AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-25-23 9:53AM L13 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-25-23 9:53AM L12 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-25-23 9:53AM L16 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-25-23 9:53AM L14 DISP PAN DISP 3 4 SENSOR OUT ALARM ALARM 7-25-23 9:53AM L15 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-25-23 9:53AM L11 PIPE DSL FILL SENSOR OUT ALARM ALARM 7-25-23 9:53AM L10 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-25-23 9:52AM L 9 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-25-23 9:52AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 7-25-23 9:52AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 7-25-23 9:52AM L13 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-25-23 9:47AM L13 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-25-23 9:46AM L14 DISP PAN DISP 3 4 FUEL ALARM CLEAR 7-25-23 9:46AM L14 DISP PAN DISP 3 4 FUEL ALARM ALARM 7-25-23 9:45AM L15 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-25-23 9:45AM L15 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-25-23 9:45AM L16 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-25-23 9:43AM L16 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-25-23 9:43AM L17 DISP PAN DISP 9-10 FUEL ALARM CLEAR 7-25-23 9:42AM L17 DISP PAN DISP 9-10 FUEL ALARM ALARM 7-25-23 9:42AM L18 DISP PAN DISP 11-12 FUEL ALARM CLEAR 7-25-23 9:41AM L18 DISP PAN DISP 11-12 FUEL ALARM ALARM 7-25-23 9:41AM L 2 PIPE UNL FILL FUEL ALARM CLEAR 7-25-23 9:39AM L 2 PIPE UNL FILL FUEL ALARM ALARM 7-25-23 9:39AM I11200 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 7-25-23 9:11AM SYSTEM PRINTER ERROR ALARM 7-25-23 9:11AM SYSTEM PRINTER ERROR CLEAR 7-16-23 7:43PM SYSTEM PAPER OUT CLEAR 7-16-23 7:43PM SYSTEM PAPER OUT ALARM 7-16-23 7:43PM SYSTEM PRINTER ERROR ALARM 7-16-23 7:43PM SYSTEM PRINTER ERROR CLEAR 6-19-23 4:52AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:45AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:45AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:45AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:45AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:44AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:44AM SYSTEM PAPER OUT CLEAR 6-18-23 3:44AM SYSTEM PRINTER ERROR ALARM 6-18-23 3:44AM SYSTEM PAPER OUT ALARM 6-18-23 3:44AM SYSTEM PRINTER ERROR CLEAR 6-18-23 3:44AM SYSTEM PAPER OUT CLEAR 6-18-23 3:44AM SYSTEM PRINTER ERROR ALARM 6-16-23 5:56PM SYSTEM PAPER OUT ALARM 6-16-23 5:56PM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 5-05-23 10:11AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 5-02-23 10:02AM OTHER ISD VAPOR LEAK WARN CLEAR 4-10-23 10:02AM SYSTEM PRINTER ERROR CLEAR 4-09-23 7:43PM SYSTEM PAPER OUT CLEAR 4-09-23 7:43PM SYSTEM PRINTER ERROR ALARM 4-09-23 7:38PM SYSTEM PAPER OUT ALARM 4-09-23 7:38PM OTHER ISD VAPOR LEAK WARN ALARM 4-09-23 10:02AM SYSTEM PRINTER ERROR CLEAR 4-09-23 8:01AM SYSTEM PAPER OUT CLEAR 4-09-23 8:01AM SYSTEM PRINTER ERROR ALARM 4-09-23 8:01AM SYSTEM PAPER OUT ALARM 4-09-23 8:01AM SYSTEM PRINTER ERROR CLEAR 4-09-23 8:00AM SYSTEM PAPER OUT CLEAR 4-09-23 8:00AM SYSTEM PRINTER ERROR ALARM 4-09-23 8:00AM SYSTEM PAPER OUT ALARM 4-09-23 8:00AM SYSTEM PRINTER ERROR CLEAR 4-09-23 8:00AM SYSTEM PAPER OUT CLEAR 4-09-23 8:00AM SYSTEM PRINTER ERROR ALARM 4-09-23 5:44AM SYSTEM PAPER OUT ALARM 4-09-23 5:44AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 4-07-23 5:08PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 4-07-23 10:02AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 4-05-23 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 4-04-23 10:02AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 3-31-23 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 3-24-23 10:02AM SYSTEM PRINTER ERROR CLEAR 3-11-23 11:23AM SYSTEM PAPER OUT CLEAR 3-11-23 11:23AM SYSTEM PRINTER ERROR ALARM 3-11-23 11:18AM SYSTEM PAPER OUT ALARM 3-11-23 11:18AM I20600 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUN 18, 2023 4:06 AM JUN 12, 2023 9:17 AM MAR 21, 2023 12:27 AM TANK 2 UNLEADED 2 OVERFILL ALARM JUL 21, 2023 11:09 AM JUL 16, 2023 10:00 AM JUL 7, 2023 11:57 AM TANK 3 PREMIUM OVERFILL ALARM NOV 5, 2022 2:16 AM TANK 4 DIESEL LOW PRODUCT ALARM FEB 13, 2021 8:05 AM DELIVERY NEEDED SEP 3, 2022 8:31 AM MAY 24, 2022 9:25 AM FEB 13, 2021 8:05 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 25, 2023 12:04 PM I30200 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:38 AM FUEL ALARM JUL 25, 2023 9:37 AM FUEL ALARM 2 UNL FILL JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:39 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 3 UNL STP JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:30 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 4 UNL 2 ANN JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:34 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 5 UNLD 2 FILL JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:37 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 6 UNL 2 STP JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:26 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 7 PREM ANN JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:32 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 8 PREM FILL JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:33 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 9 PREM STP JUL 25, 2023 9:52 AM SENSOR OUT ALARM JUL 25, 2023 9:27 AM FUEL ALARM JUL 25, 2023 9:26 AM FUEL ALARM 10 DSL ANN JUL 25, 2023 9:52 AM SENSOR OUT ALARM JUL 25, 2023 9:29 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 11 DSL FILL JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:30 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 12 DSL STP JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:28 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 13 DISP 1-2 JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:46 AM FUEL ALARM JUL 18, 2023 10:41 AM FUEL ALARM 14 DISP 3 4 JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:45 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 15 DISP 5-6 JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:45 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 16 DISP 7-8 JUL 25, 2023 9:53 AM SENSOR OUT ALARM JUL 25, 2023 9:43 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 17 DISP 9-10 JUL 25, 2023 9:52 AM SENSOR OUT ALARM JUL 25, 2023 9:42 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM 18 DISP 11-12 JUL 25, 2023 9:52 AM SENSOR OUT ALARM JUL 25, 2023 9:41 AM FUEL ALARM JUL 18, 2023 10:31 AM SENSOR OUT ALARM I31600 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 11-12 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 JUL 20, 2022 5:02 PM COMMUNICATION ALARM JUL 20, 2022 3:11 PM COMMUNICATION ALARM JUL 20, 2022 12:29 PM COMMUNICATION ALARM 7 FM 11-12 I40200 JUL 25, 2023 12:04 PM I40300 JUL 25, 2023 12:04 PM I34200 JUL 25, 2023 12:04 PM I34700 JUL 25, 2023 12:04 PM IV0100 JUL 25, 2023 12:04 PM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-05-05 10:02:01 A/L RATIO DEGRADATION FP10 BLEND3 0.79 23-05-04 10:02:12 A/L RATIO DEGRADATION FP10 BLEND3 0.78 23-05-03 10:02:05 A/L RATIO DEGRADATION FP10 BLEND3 0.78 23-05-02 10:02:06 A/L RATIO DEGRADATION FP10 BLEND3 0.79 23-04-09 10:02:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.61 23-04-07 10:02:09 A/L RATIO DEGRADATION FP 3 BLEND3 0.77 23-04-04 10:02:13 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 23-03-30 10:02:14 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 23-03-29 10:02:15 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 23-03-28 10:02:26 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-31 10:02:22 A/L RATIO DEGRADATION FP 3 BLEND3 0.72 22-08-06 10:01:53 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-08-03 10:01:09 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-13 10:01:35 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 21-04-19 10:02:18 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 20-10-23 10:01:58 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD 20-10-23 10:01:58 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD 20-10-17 10:02:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-06-14 10:01:09 A/L RATIO GROSS BLOCKAGE FP10 BLEND3 BLKD 20-06-14 10:01:09 A/L RATIO GROSS BLOCKAGE FP 9 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-25 10:02:50 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-07-25 09:55:34 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-25 09:55:34 ISD STARTUP 23-07-25 09:55:22 ISD SHUTDOWN 23-07-19 10:02:31 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-18 10:33:36 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 10:33:36 ISD STARTUP 23-07-18 10:33:17 ISD SHUTDOWN 23-07-17 10:02:59 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-16 15:54:20 READINESS ISD:PP EVR:NN EVR READINESS PENDING