Loading...
HomeMy WebLinkAboutFMC 2023Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date 10137943 07/25/23 Jaco #3367 Fastrip (East) 8001 White Lane Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/25 Vaporless Manufacturing LLC 03/14/25 OPW-1193585 04/14/25 07/25/23 Total # of Pages 7 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 420 87-1 ANNULAR L2 208 87-1 STP L3 208 87-1 FILL SUMP L5 208 87-2 STP L6 304 87-2 STP ANNULAR L7 208 87-2 FILL SUMP L8 304 87-2 FILL ANNULAR L9 303 87-2 ANNULAR L10 420 91 ANNULAR L11 208 91 STP L12 208 91 FILL SUMP L13 420 DIESEL ANNULAR L14 208 DIESEL STP L15 208 DIESEL FILL SUMP L16 208 DISPENSER 13/14 L17 208 DISPENSER 15/16 L18 208 DISPENSER 17/18 L19 208 DISPENSER 19/20 L20 208 DISPENSER 21/22 L21 208 DISPENSER 23/24 L22 208/304 VENTBOX Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 S1 463/464 UNLEADED PRODUCT S2 463/464 UNLEADED VENT S3 463/464 UNLEADED VAPOR Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 Unleaded T2 FX1V 91 Premium T3 FX1DV Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 07/25/23 NO PARKINGNO PAR KING EXISTING BUILDING L13 L14 L15L16 L17 L18 L12STP L9STP L6STP L3STP L10 L7 L4 L1 L11 L8 L5 L2 87-2 UNLEADED 12,000 GALLON87-1 UNLEADED 12,000 GALLON DIESEL12,000 GALLON 1/2 43 65 910 78 12/11 #3-366 #3-367 N 91 PREMIUM12,000 GALLON V F 87-1 UNLEADED12,000 GALLON 87-2 UNLEADED12,000 GALLON91 PREMIUM12,000 GALLON DIESEL12,000 GALLON L5STP L2STP L11STP L14STP AL6 L1 L10 L13 L7/L8 L3 L12 L15 L9 L18 L17 L16L19 L20 L21 18/17 1516 1314 2122 1920 25/24 L22 PROPERTY LINE PROPERTY LINEH W W H PRICE SIGN PRICE SIGNDIESEL PRICE SIGN #367 #366 NO PARKINGACCESS RAMPS ACCESSRAMPDUMPSTER G A A A V F V F F A A A A A F F F F V V V 366 LEGEND L1 87-1 ANNULAR L2 87-1 FILL L3 87-1 STP L4 87-2 ANNULAR L5 87-2 FILL L6 87-2 STP L7 91 ANNULAR L8 91 FILL L9 91 STP L10 DSL ANNULAR L11 DSL FILL L12 DSL STP L13 UDC 1 - 2 L14 UDC 3 - 4 L15 UDC 5 - 6 L16 UDC 7 - 8 L17 UDC 9 - 10 L18 UDC 11 -12 367 LEGEND L1 87-1 ANNULAR L2 87-1 STP ANNULAR AND SUMP SENSOR 2-TO-1 L3 87-1 FILL L5 87-2 STP L6 87- 2 STP ANNULAR L7 87-2 FILL L8 87-2 ANNULAR FILL L9 87-2 ANNULAR L10 91 ANNULAR L11 91 STP L12 91 FILL L13 DSL ANNULAR L14 DSL STP L15 DSL FILL L16 UDC 13 - 14 L17 UDC 15 - 16 L18 UDC 17 - 18 L19 UDC 19 -20 L20 UDC 21 -22 L21 UDC 23 - 24 L22 VENT BOX ANNULAR AND SUMP SENSOR 2-TO-1 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3/2 INCH DOUBLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE S1: 87-2 UNLEADED VENT LINE S2: PRODUCT SIPHON LINE AND VACUUM CHASE S3: VAPOR RETURN LINE EMERGENCY SHUT-OFF OVERFILL ALARM PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR FIRE EXTINGUISHER WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM WH A F V SITE MAP DATE REVISIONS DATE: DRAWN BY: CHECKED: APPROVED: RAC CADFILE: SHEET NO. A.P.N.:385-013-21-4 SCALE: CONVENIENCE MARKET FOR: 3101 STATE RDBAKERSFIELD, CA 93308 PROJECT OWNER: DRAWING: CD FASTRIPS - 3-366-3-367 3366-MSP FASTRIP FOOD STORE BAKERSFIELD, CALIFORNIA 933098001 WHITE LN. JACO HILL SITE PLAN C1 TAB:CERS 1"=15'-0" INCHES012 SHEET SIZE 22 X 34 01/07/2022 8001 WHITE LN. BAKERSFIELD, CA 93309 GOSFORD RD. WHITE LN. PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-097250 CERS ID 10137946 FASTRIPS 3-366 / 3-367 8001 WHITE LN. BAKERSFIELD, CA 93309 02/12/2021 REV. VICINITY MAP PROJECT DATA APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #3367 Fastrip (East)8001 White LaneBakersfield1013794315/1619/20 23/24MPDMPDMPDMPDMPDMPD13/1417/1821/22ProductProductProductProductProductProductMark Fisher Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10137943 07/25/23 Jaco #3367 Fastrip (East) 8001 White Lane Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/25 OPW-1193585 04/14/25 PEI1200, 1 hour hydrostatic test All Spill Containers 07/25/23 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1; 87-1 OPW T2; 87-2 OPW T3; 91 OPW T4; Diesel OPW System Setup 8001 White Lane (East) Responses Received: 200 FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 JUL 25, 2023 1:28 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 8519 74.12 0.9 82.4 3549 2 UNLEADED 2 7916 59.01 0.8 82.7 3766 3 PREMIUM 8199 72.35 0.0 83.8 3801 4 DIESEL 3627 38.31 0.0 82.8 8373 I90500 JUL 25, 2023 1:28 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 25, 2023 1:28 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 25, 2023 1:28 PM SHIFT TIME 1 : 6:00 AM I50202 JUL 25, 2023 1:28 PM SHIFT TIME 2 : DISABLED I50203 JUL 25, 2023 1:28 PM SHIFT TIME 3 : DISABLED I50204 JUL 25, 2023 1:28 PM SHIFT TIME 4 : DISABLED I54600 JUL 25, 2023 1:28 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 25, 2023 1:28 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 25, 2023 1:28 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 25, 2023 1:28 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 25, 2023 1:28 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 25, 2023 1:28 PM PRINT TC VOLUMES ENABLED I50E00 JUL 25, 2023 1:28 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 25, 2023 1:28 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 25, 2023 1:28 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 25, 2023 1:28 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 25, 2023 1:28 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 25, 2023 1:28 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 25, 2023 1:28 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 25, 2023 1:28 PM TANK CHART SECURITY DISABLED I5BD00 JUL 25, 2023 1:28 PM CUSTOM ALARM LABELS DISABLED I56000 JUL 25, 2023 1:28 PM MASS/DENSITY DISABLED I88101 JUL 25, 2023 1:28 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 25, 2023 1:28 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 25, 2023 1:28 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 25, 2023 1:28 PM I88105 JUL 25, 2023 1:28 PM I88106 JUL 25, 2023 1:28 PM I52000 JUL 25, 2023 1:28 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE SEP 8, 2011 DISABLED 2 ON DATE SEP 8, 2011 DISABLED 3 ON DATE SEP 8, 2011 DISABLED 4 ON DATE SEP 8, 2011 DISABLED 5 ON DATE SEP 8, 2011 DISABLED 6 ON DATE SEP 8, 2011 DISABLED 7 ON DATE SEP 8, 2011 DISABLED 8 ON DATE SEP 8, 2011 DISABLED I60100 JUL 25, 2023 1:28 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 UNLEADED 2 ON 3 PREMIUM ON 4 DIESEL ON I60200 JUL 25, 2023 1:28 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 UNLEADED 2 3 PREMIUM 4 DIESEL I60300 JUL 25, 2023 1:28 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 2 3 PREMIUM 3 4 DIESEL 4 I60900 JUL 25, 2023 1:28 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 UNLEADED 2 0.000700 3 PREMIUM 0.000700 4 DIESEL 0.000450 I60700 JUL 25, 2023 1:28 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.50 2 UNLEADED 2 92.00 3 PREMIUM 112.00 4 DIESEL 112.00 I60A00 JUL 25, 2023 1:28 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12068 2 UNLEADED 2 1 PT 11682 3 PREMIUM 1 PT 12000 4 DIESEL 1 PT 12000 I60400 JUL 25, 2023 1:28 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12068 2 UNLEADED 2 11682 3 PREMIUM 12000 4 DIESEL 12000 I60500 JUL 25, 2023 1:28 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12068 0 0 0 2 UNLEADED 2 11682 0 0 0 3 PREMIUM 12000 0 0 0 4 DIESEL 12000 0 0 0 I60600 JUL 25, 2023 1:28 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12068 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNLEADED 2 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 25, 2023 1:28 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 UNLEADED 2 NO 3 PREMIUM NO 4 DIESEL NO I62F00 JUL 25, 2023 1:28 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 UNLEADED 2 4.0 IN. 3 PREMIUM 3.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 25, 2023 1:28 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 UNLEADED 2 2.0 3 PREMIUM 2.0 4 DIESEL 2.0 I64200 JUL 25, 2023 1:28 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 UNLEADED 2 LOW 3 PREMIUM LOW 4 DIESEL LOW I62400 JUL 25, 2023 1:28 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 UNLEADED 2 3.0 3 PREMIUM 3.0 4 DIESEL 3.0 I62800 JUL 25, 2023 1:28 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12068 2 UNLEADED 2 11682 3 PREMIUM 12000 4 DIESEL 12000 I62300 JUL 25, 2023 1:28 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10861 2 UNLEADED 2 10514 3 PREMIUM 10800 4 DIESEL 10800 I62200 JUL 25, 2023 1:28 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11465 2 UNLEADED 2 11098 3 PREMIUM 11400 4 DIESEL 11400 I62900 JUL 25, 2023 1:28 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1200 2 UNLEADED 2 1200 3 PREMIUM 1200 4 DIESEL 1200 I62100 JUL 25, 2023 1:29 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1200 2 UNLEADED 2 1200 3 PREMIUM 1200 4 DIESEL 1200 I62600 JUL 25, 2023 1:29 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I62500 JUL 25, 2023 1:29 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I60800 JUL 25, 2023 1:29 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED -3.25 2 UNLEADED 2 -4.50 3 PREMIUM 0.00 4 DIESEL 0.00 I60B00 JUL 25, 2023 1:29 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 25, 2023 1:29 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I61200 JUL 25, 2023 1:29 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 UNLEADED 2 NONE NONE 3 PREMIUM NONE NONE 4 DIESEL NONE NONE I63600 JUL 25, 2023 1:29 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62A00 JUL 25, 2023 1:29 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62C00 JUL 25, 2023 1:29 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 UNLEADED 2 STANDARD 3 PREMIUM STANDARD 4 DIESEL STANDARD I62D00 JUL 25, 2023 1:29 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 25, 2023 1:29 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 UNLEADED 2 OFF OFF 3 PREMIUM OFF OFF 4 DIESEL OFF OFF I63000 JUL 25, 2023 1:29 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I63200 JUL 25, 2023 1:29 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I61000 JUL 25, 2023 1:29 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63A00 JUL 25, 2023 1:29 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 UNLEADED 2 10.00% 3 PREMIUM 10.00% 4 DIESEL 10.00% I61100 JUL 25, 2023 1:29 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK OCT 9, 2008 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 25, 2023 1:29 PM CSLD PROBABLITY OF DETECTION I61400 JUL 25, 2023 1:29 PM CSLD CLIMATE FACTOR I61600 JUL 25, 2023 1:29 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 UNLEADED 2 IMMEDIATE 3 PREMIUM IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 25, 2023 1:29 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 UNLEADED 2 DISABLED 3 PREMIUM DISABLED 4 DIESEL DISABLED I61B00 JUL 25, 2023 1:29 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 25, 2023 1:29 PM CSLD REPORT ONLY I62B00 JUL 25, 2023 1:29 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 UNLEADED 2 ??? 0, 0 3 PREMIUM ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 25, 2023 1:29 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 25, 2023 1:29 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 UNLEADED 2 0 3 PREMIUM 0 4 DIESEL 0 I63500 JUL 25, 2023 1:29 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63900 JUL 25, 2023 1:29 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 UNLEADED 2 END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 25, 2023 1:29 PM I77700 JUL 25, 2023 1:29 PM I77800 JUL 25, 2023 1:29 PM I78C00 JUL 25, 2023 1:29 PM I78300 JUL 25, 2023 1:29 PM I78F00 JUL 25, 2023 1:29 PM I78700 JUL 25, 2023 1:29 PM I70200 JUL 25, 2023 1:29 PM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 UNL STP 3 UNL FILL 4 UNL 2 STP 5 UNL 2 STP 6 UNL 2 STP ANN 7 UNL 2 FILL 8 UNL 2 ANN FILL 9 UNL 2 ANN 10 PREM ANN 11 PREM STP 12 PREM FILL 13 DSL ANN 14 DSL STP 15 DSL FILL 16 DISP 13-14 17 DISP 15-16 18 DISP 17-18 19 DISP 19-20 20 DISP 21-22 21 DISP 23-24 22 VENTBOX 23 24 I70300 JUL 25, 2023 1:29 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 UNL STP TRI-STATE (SINGLE FLOAT) 3 UNL FILL TRI-STATE (SINGLE FLOAT) 4 UNL 2 STP TRI-STATE (SINGLE FLOAT) 5 UNL 2 STP TRI-STATE (SINGLE FLOAT) 6 UNL 2 STP ANN TRI-STATE (SINGLE FLOAT) 7 UNL 2 FILL TRI-STATE (SINGLE FLOAT) 8 UNL 2 ANN FILL TRI-STATE (SINGLE FLOAT) 9 UNL 2 ANN DUAL POINT HYDROSTATIC 10 PREM ANN TRI-STATE (SINGLE FLOAT) 11 PREM STP TRI-STATE (SINGLE FLOAT) 12 PREM FILL TRI-STATE (SINGLE FLOAT) 13 DSL ANN TRI-STATE (SINGLE FLOAT) 14 DSL STP TRI-STATE (SINGLE FLOAT) 15 DSL FILL TRI-STATE (SINGLE FLOAT) 16 DISP 13-14 TRI-STATE (SINGLE FLOAT) 17 DISP 15-16 TRI-STATE (SINGLE FLOAT) 18 DISP 17-18 TRI-STATE (SINGLE FLOAT) 19 DISP 19-20 TRI-STATE (SINGLE FLOAT) 20 DISP 21-22 TRI-STATE (SINGLE FLOAT) 21 DISP 23-24 TRI-STATE (SINGLE FLOAT) 22 VENTBOX DW SUMP 2-1 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 JUL 25, 2023 1:29 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 UNL STP STP SUMP 3 UNL FILL PIPING SUMP 4 UNL 2 STP STP SUMP 5 UNL 2 STP STP SUMP 6 UNL 2 STP ANN ANNULAR SPACE 7 UNL 2 FILL PIPING SUMP 8 UNL 2 ANN FILL ANNULAR SPACE 9 UNL 2 ANN ANNULAR SPACE 10 PREM ANN ANNULAR SPACE 11 PREM STP STP SUMP 12 PREM FILL PIPING SUMP 13 DSL ANN ANNULAR SPACE 14 DSL STP STP SUMP 15 DSL FILL OTHER SENSORS 16 DISP 13-14 DISPENSER PAN 17 DISP 15-16 DISPENSER PAN 18 DISP 17-18 DISPENSER PAN 19 DISP 19-20 DISPENSER PAN 20 DISP 21-22 DISPENSER PAN 21 DISP 23-24 DISPENSER PAN 22 VENTBOX PIPING SUMP 23 OTHER SENSORS 24 OTHER SENSORS I74200 JUL 25, 2023 1:29 PM I74300 JUL 25, 2023 1:29 PM I74400 JUL 25, 2023 1:29 PM I74700 JUL 25, 2023 1:29 PM I74800 JUL 25, 2023 1:29 PM I74900 JUL 25, 2023 1:29 PM I7BC00 JUL 25, 2023 1:29 PM I80200 JUL 25, 2023 1:29 PM I80300 JUL 25, 2023 1:29 PM I80400 JUL 25, 2023 1:29 PM I80700 JUL 25, 2023 1:29 PM RELAY LABEL DEVICE LABEL 1 POS SHUT OFF 2 3 UNLD 1 4 OVERFILL ALARM 5 INTERNAL ALARM 6 7 8 ANNUNCIATOR I80900 JUL 25, 2023 1:29 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 POS SHUT OFF NORMALLY CLOSED 2 NORMALLY OPEN 3 UNLD 1 NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN 5 INTERNAL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 ANNUNCIATOR NORMALLY CLOSED I80B00 JUL 25, 2023 1:29 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 POS SHUT OFF 1 2 NONE 3 UNLD 1 1 4 OVERFILL ALARM NONE 5 INTERNAL ALARM NONE 6 NONE 7 NONE 8 ANNUNCIATOR NONE I80A00 JUL 25, 2023 1:29 PM RELAY TYPE RELAY DESIGNATION TYPE 1 POS SHUT OFF STANDARD 2 STANDARD 3 UNLD 1 PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD 5 INTERNAL ALARM MOMENTARY 6 STANDARD 7 STANDARD 8 ANNUNCIATOR STANDARD I80C00 JUL 25, 2023 1:29 PM I80800 JUL 25, 2023 1:29 PM RELAY SETUP REPORT R 1:POS SHUT OFF TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 2:FUEL ALARM L 5:FUEL ALARM L11:FUEL ALARM L14:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L20:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L11:SENSOR OUT ALARM L14:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L20:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L11:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM L19:SHORT ALARM L20:SHORT ALARM L21:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 3:UNLD 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 2:FUEL ALARM L 5:FUEL ALARM L11:FUEL ALARM L14:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L20:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L11:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L20:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 5:SHORT ALARM L11:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM L19:SHORT ALARM L20:SHORT ALARM L21:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 5:INTERNAL ALARM TYPE: MOMENTARY NORMALLY OPEN LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM SMARTSENSOR ALARMS ALL:NO VACUUM ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8:ANNUNCIATOR TYPE: STANDARD NORMALLY CLOSED TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:GROSS TEST FAIL ALL:PERIODIC TEST FAIL ALL:ANNUAL TEST FAIL ALL:PER TST NEEDED WRN ALL:ANN TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:ANN TST NEEDED ALM ALL:TANK TEST ACTIVE ALL:NO CSLD IDLE TIME ALL:TANK SIPHON BREAK ALL:CSLD INCR RATE WARN ALL:ACCU_CHART CAL WARN ALL:RECON WARNING ALL:RECON ALARM ALL:LOW TEMP WARNING ALL:MISSING TICKET WARN ALL:GROSS FAIL LINE TNK ALL:DELIVY DENSITY WARN LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT WARN ALL:DEGRD COLLECT WARN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT WARN ALL:FLOW COLLECT FAIL ALL:AIRFLOW MTR SETUP I79000 JUL 25, 2023 1:30 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 25, 2023 1:30 PM I72300 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNL 2 LINE VAC SENSOR 02 UNL 2 VENT VAC SENSOR 03 VAPOR VAC SENSOR 04 UNKNOWN 05 UNKNOWN 06 UNKNOWN 07 UNKNOWN 08 ATM ATM P SENSOR 09 PS 17-18 VAPOR PRESSURE 10 FM 13-14 AIR FLOW METER 11 FM 15-16 AIR FLOW METER 12 FM 17-18 AIR FLOW METER 13 FM 19-20 AIR FLOW METER 14 FM 21-22 AIR FLOW METER 15 FM 23-24 AIR FLOW METER 16 PS 17-18 VAPOR PRESSURE 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 VAPOR PROCESSOR TYPE NONE IV4700 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ACCEPT HIGH ORVR: NO IV4A00 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 13 01 08 BLEND3 02 02 14 01 08 BLEND3 03 03 15 02 08 BLEND3 04 04 16 02 08 BLEND3 05 05 17 03 08 BLEND3 06 06 18 03 08 BLEND3 07 07 19 04 08 BLEND3 08 08 20 04 08 BLEND3 09 09 21 05 08 BLEND3 10 10 22 05 08 BLEND3 11 11 23 06 08 BLEND3 12 12 24 06 08 BLEND3 IV4B00 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 03/01 09/01 02/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx 09 05 02/09 03/09 09/09 xx/xx 10 05 02/10 03/10 09/10 xx/xx 11 06 02/11 03/11 09/11 xx/xx 12 06 02/12 03/12 09/12 xx/xx IV4900 JUL 25, 2023 1:30 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 25, 2023 1:30 PM ISD VERSION: 01.07 Alarm History 8001 White Lane (East) Before: Responses Received: I10200 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508187 507187 2 8SMARTSENSOR BD 39563 39552 3 4 PROBE / G.T. 164174 164123 4 INTERSTITIAL BD 201747 201846 5 INTERSTITIAL BD 202287 202224 6 INTERSTITIAL BD 202663 202485 7 UNUSED 4972927 4934133 8 UNUSED 4968243 4929371 9 RELAY BOARD 14927 14926 10 STP SENSE BOARD 33409 33412 11 RELAY BOARD 15145 15124 12 UNUSED 4969915 4937164 13 UNUSED 4967421 4934303 14 UNUSED 4967313 4937055 15 UNUSED 4965187 4936072 16 UNUSED 4968245 4937405 COMM 1 ELEC DISP INT. 101470 101464 COMM 2 RS232 SERIAL BD 15014 15014 COMM 3 RS232 SERIAL BD 14992 14992 COMM 4 UNUSED 4964884 4942757 COMM 5 UNUSED 4961392 4939611 COMM 6 UNUSED 4961739 4936378 I90200 JUL 25, 2023 1:31 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 5 STP SUMP UNL 2 STP FUEL ALARM CLEAR 7-18-23 2:37PM L 5 STP SUMP UNL 2 STP FUEL ALARM ALARM 7-18-23 2:37PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L15 OTHER DSL FILL SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L14 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L12 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L11 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L10 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L13 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L22 PIPE VENTBOX SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM CLEAR 7-18-23 2:29PM L 2 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 7 PIPE UNL 2 FILL SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 6 ANNULAR UNL 2 STP ANN SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 3 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 8 ANNULAR UNL 2 ANN FILL SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-18-23 2:28PM L 7 PIPE UNL 2 FILL SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 6 ANNULAR UNL 2 STP ANN SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 3 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 2 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-18-23 2:28PM L14 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-18-23 2:28PM L12 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-18-23 2:28PM L11 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-18-23 2:28PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM ALARM 7-18-23 2:28PM L15 OTHER DSL FILL SENSOR OUT ALARM ALARM 7-18-23 2:28PM L10 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-18-23 2:28PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM ALARM 7-18-23 2:28PM L13 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 8 ANNULAR UNL 2 ANN FILL SENSOR OUT ALARM ALARM 7-18-23 2:28PM L22 PIPE VENTBOX SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-18-23 2:28PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM ALARM 7-18-23 2:28PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM ALARM 7-18-23 2:28PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM ALARM 7-18-23 2:28PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM ALARM 7-18-23 2:28PM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 7-18-23 1:41PM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 7-18-23 1:41PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-18-23 1:36PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-18-23 1:23PM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 7-18-23 1:22PM L15 OTHER DSL FILL FUEL ALARM CLEAR 7-18-23 1:19PM I11200 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 6-26-23 4:37AM SYSTEM PAPER OUT CLEAR 6-26-23 4:37AM SYSTEM PRINTER ERROR ALARM 6-26-23 4:36AM SYSTEM PAPER OUT ALARM 6-26-23 4:36AM h10 OTHER FP22: BLEND3 DEGRD COLLECT WARN CLEAR 6-19-23 1:29PM h 2 OTHER FP14: BLEND3 DEGRD COLLECT WARN CLEAR 6-19-23 1:29PM h 2 OTHER FP14: BLEND3 DEGRD COLLECT WARN ALARM 6-18-23 10:01AM h10 OTHER FP22: BLEND3 DEGRD COLLECT WARN ALARM 6-15-23 10:02AM OTHER ISD SENSOR OUT WARN CLEAR 5-16-23 5:14PM h 2 OTHER FP14: BLEND3 GROSS COLLECT WARN CLEAR 5-16-23 5:13PM h 1 OTHER FP13: BLEND3 GROSS COLLECT WARN CLEAR 5-16-23 5:13PM OTHER ISD VAPOR LEAK WARN CLEAR 5-16-23 3:43PM h 2 OTHER FP14: BLEND3 GROSS COLLECT WARN ALARM 5-16-23 10:01AM h 1 OTHER FP13: BLEND3 GROSS COLLECT WARN ALARM 5-16-23 10:01AM OTHER ISD SENSOR OUT WARN ALARM 5-15-23 10:01AM SYSTEM PRINTER ERROR CLEAR 5-14-23 5:33AM SYSTEM PAPER OUT CLEAR 5-14-23 5:33AM SYSTEM PAPER OUT ALARM 5-14-23 5:33AM SYSTEM PRINTER ERROR ALARM 5-14-23 5:33AM SYSTEM PRINTER ERROR CLEAR 5-14-23 5:32AM SYSTEM PAPER OUT CLEAR 5-14-23 5:32AM SYSTEM PRINTER ERROR ALARM 5-13-23 11:58PM SYSTEM PAPER OUT ALARM 5-13-23 11:58PM OTHER ISD VAPOR LEAK WARN ALARM 5-12-23 10:01AM SYSTEM PRINTER ERROR CLEAR 4-09-23 5:48AM SYSTEM PAPER OUT CLEAR 4-09-23 5:48AM SYSTEM PRINTER ERROR ALARM 4-09-23 5:47AM SYSTEM PAPER OUT ALARM 4-09-23 5:47AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 4-07-23 5:11PM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 4-06-23 10:01AM SYSTEM PRINTER ERROR CLEAR 2-22-23 1:05PM SYSTEM PAPER OUT CLEAR 2-22-23 1:05PM SYSTEM PRINTER ERROR ALARM 2-22-23 12:55PM SYSTEM PAPER OUT ALARM 2-22-23 12:55PM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN CLEAR 2-21-23 10:00AM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN ALARM 2-18-23 10:02AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 2-15-23 5:09PM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 2-13-23 10:03AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 1-31-23 7:33PM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN CLEAR 1-30-23 10:00AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 1-29-23 10:02AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 1-28-23 10:00AM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN ALARM 1-27-23 10:02AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 1-25-23 10:02AM SYSTEM PRINTER ERROR CLEAR 1-24-23 10:24AM SYSTEM PAPER OUT CLEAR 1-24-23 10:24AM SYSTEM PAPER OUT ALARM 1-24-23 10:22AM SYSTEM PRINTER ERROR ALARM 1-24-23 10:22AM SYSTEM PRINTER ERROR CLEAR 1-24-23 4:07AM SYSTEM PAPER OUT CLEAR 1-24-23 4:07AM I20600 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM MAY 30, 2023 7:41 AM MAY 29, 2023 9:38 AM MAY 28, 2023 9:15 AM SUDDEN LOSS ALARM JUN 25, 2023 2:07 AM MAY 27, 2023 1:06 AM MAY 14, 2022 3:11 AM TANK 2 UNLEADED 2 OVERFILL ALARM JUL 9, 2023 6:11 AM JUL 7, 2023 10:36 AM APR 11, 2023 3:19 AM HIGH PRODUCT ALARM SEP 10, 2022 6:24 AM AUG 29, 2022 2:39 PM TANK 3 PREMIUM OVERFILL ALARM SEP 23, 2022 2:02 AM JUL 28, 2022 11:09 AM LOW PRODUCT ALARM SEP 11, 2022 1:59 PM DELIVERY NEEDED SEP 11, 2022 1:59 PM TANK 4 DIESEL LOW PRODUCT ALARM OCT 12, 2022 10:27 PM DELIVERY NEEDED OCT 12, 2022 10:27 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 25, 2023 1:31 PM I30200 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:41 PM FUEL ALARM JUL 18, 2023 1:23 PM SENSOR OUT ALARM 2 UNL STP JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:49 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 3 UNL FILL JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:03 PM FUEL ALARM MAR 13, 2023 1:45 PM FUEL ALARM 5 UNL 2 STP JUL 18, 2023 2:37 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:48 PM FUEL ALARM 6 UNL 2 STP ANN JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:49 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 7 UNL 2 FILL JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:03 PM FUEL ALARM MAY 2, 2023 9:13 AM FUEL ALARM 8 UNL 2 ANN FILL JUL 18, 2023 2:28 PM SENSOR OUT ALARM FEB 28, 2023 2:29 PM FUEL ALARM FEB 28, 2023 1:37 PM FUEL ALARM 9 UNL 2 ANN JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:02 PM HIGH LIQUID ALARM JUL 18, 2023 1:02 PM LOW LIQUID ALARM 10 PREM ANN JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:54 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 11 PREM STP JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:52 PM FUEL ALARM JUN 6, 2023 6:58 AM FUEL ALARM 12 PREM FILL JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:04 PM FUEL ALARM JUN 6, 2023 10:23 PM FUEL ALARM 13 DSL ANN JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:53 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 14 DSL STP JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 12:52 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 15 DSL FILL JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:18 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 16 DISP 13-14 JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:09 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 17 DISP 15-16 JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:10 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 18 DISP 17-18 JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:11 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 19 DISP 19-20 JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:08 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 20 DISP 21-22 JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:07 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 21 DISP 23-24 JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:05 PM FUEL ALARM JUL 25, 2022 11:46 AM SENSOR OUT ALARM 22 VENTBOX JUL 18, 2023 2:28 PM SENSOR OUT ALARM JUL 18, 2023 1:18 PM FUEL ALARM NOV 15, 2022 12:03 AM LOW LIQUID ALARM I31600 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 2 LINE JUL 25, 2022 11:32 AM HIGH LIQUID ALARM JUL 25, 2022 11:31 AM NO VACUUM ALARM JUL 20, 2022 12:16 PM HIGH LIQUID ALARM 2 UNL 2 VENT AUG 18, 2022 5:27 PM NO VACUUM ALARM JUL 25, 2022 11:31 AM NO VACUUM ALARM JUL 20, 2022 12:15 PM NO VACUUM ALARM 3 VAPOR DEC 2, 2022 2:18 AM SENSOR FAULT ALARM AUG 18, 2022 6:03 PM NO VACUUM ALARM AUG 18, 2022 5:47 PM NO VACUUM ALARM 8 ATM 10 FM 13-14 11 FM 15-16 12 FM 17-18 13 FM 19-20 14 FM 21-22 15 FM 23-24 16 PS 17-18 MAY 24, 2023 3:02 PM COMMUNICATION ALARM I40200 JUL 25, 2023 1:31 PM I40300 JUL 25, 2023 1:31 PM I34200 JUL 25, 2023 1:31 PM I34700 JUL 25, 2023 1:31 PM IV0100 JUL 25, 2023 1:31 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-06-19 10:01:26 A/L RATIO DEGRADATION FP22 BLEND3 0.74 23-06-19 10:01:26 A/L RATIO DEGRADATION FP14 BLEND3 0.77 23-06-18 10:01:43 A/L RATIO DEGRADATION FP22 BLEND3 0.77 23-06-18 10:01:43 A/L RATIO DEGRADATION FP14 BLEND3 0.78 23-06-17 10:01:51 A/L RATIO DEGRADATION FP22 BLEND3 0.78 23-06-16 10:01:45 A/L RATIO DEGRADATION FP22 BLEND3 0.79 23-06-15 10:02:20 A/L RATIO DEGRADATION FP22 BLEND3 0.80 23-05-16 10:01:40 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:FM 13-14 23-05-16 10:01:40 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 159.83 23-05-16 10:01:40 A/L RATIO GROSS BLOCKAGE FP14 BLEND3 BLKD FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-01-20 10:02:36 A/L RATIO DEGRADATION FP18 BLEND3 0.72 21-10-27 10:03:09 A/L RATIO GROSS BLOCKAGE FP24 BLEND3 BLKD 20-12-02 10:02:55 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 56.91 19-05-17 08:31:19 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-16 08:31:33 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-15 08:31:32 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-14 08:31:21 SENSOR OUT SELFTEST T 1 19-05-14 08:31:21 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-14 08:31:20 SETUP SELFTEST MISSING TANK(S) 19-05-13 08:31:17 SENSOR OUT SELFTEST T 1 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-19 10:02:36 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-18 14:31:32 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 14:31:32 ISD STARTUP 23-07-18 14:31:06 ISD SHUTDOWN 23-07-17 10:02:31 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-16 15:58:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-16 15:58:51 ISD STARTUP 23-07-16 15:58:23 ISD SHUTDOWN 23-06-19 13:29:46 COLLECTION TEST HH10 GRADE TEST MANUALLY CLEARED 23-06-19 13:29:21 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED After: Responses Received: I10200 JUL 25, 2023 4:20 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508187 507586 2 8SMARTSENSOR BD 39563 39528 3 4 PROBE / G.T. 164174 164006 4 INTERSTITIAL BD 201747 201748 5 INTERSTITIAL BD 202287 202103 6 INTERSTITIAL BD 202663 202458 7 UNUSED 4972927 4939567 8 UNUSED 4968243 4938018 9 RELAY BOARD 14927 14912 10 STP SENSE BOARD 33409 33352 11 RELAY BOARD 15145 15131 12 UNUSED 4969915 4938996 13 UNUSED 4967421 4944189 14 UNUSED 4967313 4938254 15 UNUSED 4965187 4940851 16 UNUSED 4968245 4941156 COMM 1 ELEC DISP INT. 101470 101430 COMM 2 RS232 SERIAL BD 15014 15000 COMM 3 RS232 SERIAL BD 14992 14978 COMM 4 UNUSED 4964884 4943229 COMM 5 UNUSED 4961392 4944233 COMM 6 UNUSED 4961739 4938865 I90200 JUL 25, 2023 4:20 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 25, 2023 4:20 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 2 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 8 ANNULAR UNL 2 ANN FILL SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 7 PIPE UNL 2 FILL SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 6 ANNULAR UNL 2 STP ANN SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L12 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 3 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L11 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L13 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L15 OTHER DSL FILL SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L10 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L14 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-25-23 2:13PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L22 PIPE VENTBOX SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L12 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-25-23 2:13PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 8 ANNULAR UNL 2 ANN FILL SENSOR OUT ALARM ALARM 7-25-23 2:13PM L 2 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-25-23 2:13PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L 7 PIPE UNL 2 FILL SENSOR OUT ALARM ALARM 7-25-23 2:13PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM CLEAR 7-25-23 2:13PM L14 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-25-23 2:13PM L11 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-25-23 2:13PM L13 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-25-23 2:13PM L10 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-25-23 2:12PM L 6 ANNULAR UNL 2 STP ANN SENSOR OUT ALARM ALARM 7-25-23 2:12PM L 3 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-25-23 2:12PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-25-23 2:12PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM ALARM 7-25-23 2:12PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-25-23 2:12PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-25-23 2:12PM L15 OTHER DSL FILL SENSOR OUT ALARM ALARM 7-25-23 2:12PM L22 PIPE VENTBOX SENSOR OUT ALARM ALARM 7-25-23 2:12PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM ALARM 7-25-23 2:12PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM ALARM 7-25-23 2:12PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM ALARM 7-25-23 2:12PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM ALARM 7-25-23 2:12PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM ALARM 7-25-23 2:12PM L15 OTHER DSL FILL FUEL ALARM CLEAR 7-25-23 2:11PM L15 OTHER DSL FILL FUEL ALARM ALARM 7-25-23 2:11PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM CLEAR 7-25-23 2:11PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM ALARM 7-25-23 2:11PM L22 PIPE VENTBOX FUEL ALARM CLEAR 7-25-23 2:06PM L22 PIPE VENTBOX FUEL ALARM ALARM 7-25-23 2:06PM I11200 JUL 25, 2023 4:20 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 6-26-23 4:37AM SYSTEM PAPER OUT CLEAR 6-26-23 4:37AM SYSTEM PRINTER ERROR ALARM 6-26-23 4:36AM SYSTEM PAPER OUT ALARM 6-26-23 4:36AM h10 OTHER FP22: BLEND3 DEGRD COLLECT WARN CLEAR 6-19-23 1:29PM h 2 OTHER FP14: BLEND3 DEGRD COLLECT WARN CLEAR 6-19-23 1:29PM h 2 OTHER FP14: BLEND3 DEGRD COLLECT WARN ALARM 6-18-23 10:01AM h10 OTHER FP22: BLEND3 DEGRD COLLECT WARN ALARM 6-15-23 10:02AM OTHER ISD SENSOR OUT WARN CLEAR 5-16-23 5:14PM h 2 OTHER FP14: BLEND3 GROSS COLLECT WARN CLEAR 5-16-23 5:13PM h 1 OTHER FP13: BLEND3 GROSS COLLECT WARN CLEAR 5-16-23 5:13PM OTHER ISD VAPOR LEAK WARN CLEAR 5-16-23 3:43PM h 2 OTHER FP14: BLEND3 GROSS COLLECT WARN ALARM 5-16-23 10:01AM h 1 OTHER FP13: BLEND3 GROSS COLLECT WARN ALARM 5-16-23 10:01AM OTHER ISD SENSOR OUT WARN ALARM 5-15-23 10:01AM SYSTEM PRINTER ERROR CLEAR 5-14-23 5:33AM SYSTEM PAPER OUT CLEAR 5-14-23 5:33AM SYSTEM PAPER OUT ALARM 5-14-23 5:33AM SYSTEM PRINTER ERROR ALARM 5-14-23 5:33AM SYSTEM PRINTER ERROR CLEAR 5-14-23 5:32AM SYSTEM PAPER OUT CLEAR 5-14-23 5:32AM SYSTEM PRINTER ERROR ALARM 5-13-23 11:58PM SYSTEM PAPER OUT ALARM 5-13-23 11:58PM OTHER ISD VAPOR LEAK WARN ALARM 5-12-23 10:01AM SYSTEM PRINTER ERROR CLEAR 4-09-23 5:48AM SYSTEM PAPER OUT CLEAR 4-09-23 5:48AM SYSTEM PRINTER ERROR ALARM 4-09-23 5:47AM SYSTEM PAPER OUT ALARM 4-09-23 5:47AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 4-07-23 5:11PM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 4-06-23 10:01AM SYSTEM PRINTER ERROR CLEAR 2-22-23 1:05PM SYSTEM PAPER OUT CLEAR 2-22-23 1:05PM SYSTEM PRINTER ERROR ALARM 2-22-23 12:55PM SYSTEM PAPER OUT ALARM 2-22-23 12:55PM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN CLEAR 2-21-23 10:00AM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN ALARM 2-18-23 10:02AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 2-15-23 5:09PM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 2-13-23 10:03AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 1-31-23 7:33PM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN CLEAR 1-30-23 10:00AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 1-29-23 10:02AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN CLEAR 1-28-23 10:00AM h 3 OTHER FP15: BLEND3 DEGRD COLLECT WARN ALARM 1-27-23 10:02AM h 6 OTHER FP18: BLEND3 DEGRD COLLECT WARN ALARM 1-25-23 10:02AM SYSTEM PRINTER ERROR CLEAR 1-24-23 10:24AM SYSTEM PAPER OUT CLEAR 1-24-23 10:24AM SYSTEM PAPER OUT ALARM 1-24-23 10:22AM SYSTEM PRINTER ERROR ALARM 1-24-23 10:22AM SYSTEM PRINTER ERROR CLEAR 1-24-23 4:07AM SYSTEM PAPER OUT CLEAR 1-24-23 4:07AM I20600 JUL 25, 2023 4:20 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM MAY 30, 2023 7:41 AM MAY 29, 2023 9:38 AM MAY 28, 2023 9:15 AM SUDDEN LOSS ALARM JUN 25, 2023 2:07 AM MAY 27, 2023 1:06 AM MAY 14, 2022 3:11 AM TANK 2 UNLEADED 2 OVERFILL ALARM JUL 9, 2023 6:11 AM JUL 7, 2023 10:36 AM APR 11, 2023 3:19 AM HIGH PRODUCT ALARM SEP 10, 2022 6:24 AM AUG 29, 2022 2:39 PM TANK 3 PREMIUM OVERFILL ALARM SEP 23, 2022 2:02 AM JUL 28, 2022 11:09 AM LOW PRODUCT ALARM SEP 11, 2022 1:59 PM DELIVERY NEEDED SEP 11, 2022 1:59 PM TANK 4 DIESEL LOW PRODUCT ALARM OCT 12, 2022 10:27 PM DELIVERY NEEDED OCT 12, 2022 10:27 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 25, 2023 4:20 PM I30200 JUL 25, 2023 4:20 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:52 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 2 UNL STP JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 1:41 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 3 UNL FILL JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:55 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 5 UNL 2 STP JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:48 PM FUEL ALARM JUL 18, 2023 2:37 PM FUEL ALARM 6 UNL 2 STP ANN JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:48 PM FUEL ALARM JUL 25, 2023 1:42 PM FUEL ALARM 7 UNL 2 FILL JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 1:54 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 8 UNL 2 ANN FILL JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 2:11 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 9 UNL 2 ANN JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:52 PM LOW LIQUID ALARM 10 PREM ANN JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:52 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 11 PREM STP JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 1:49 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 12 PREM FILL JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 1:55 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 13 DSL ANN JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 1:51 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 14 DSL STP JUL 25, 2023 2:13 PM SENSOR OUT ALARM JUL 25, 2023 1:50 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 15 DSL FILL JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 2:11 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 16 DISP 13-14 JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:57 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 17 DISP 15-16 JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 2:01 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 18 DISP 17-18 JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 2:03 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 19 DISP 19-20 JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 1:59 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 20 DISP 21-22 JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 2:00 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 21 DISP 23-24 JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 2:02 PM FUEL ALARM JUL 18, 2023 2:28 PM SENSOR OUT ALARM 22 VENTBOX JUL 25, 2023 2:12 PM SENSOR OUT ALARM JUL 25, 2023 2:06 PM FUEL ALARM JUL 25, 2023 2:05 PM LOW LIQUID ALARM I31600 JUL 25, 2023 4:21 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 2 LINE JUL 25, 2022 11:32 AM HIGH LIQUID ALARM JUL 25, 2022 11:31 AM NO VACUUM ALARM JUL 20, 2022 12:16 PM HIGH LIQUID ALARM 2 UNL 2 VENT AUG 18, 2022 5:27 PM NO VACUUM ALARM JUL 25, 2022 11:31 AM NO VACUUM ALARM JUL 20, 2022 12:15 PM NO VACUUM ALARM 3 VAPOR DEC 2, 2022 2:18 AM SENSOR FAULT ALARM AUG 18, 2022 6:03 PM NO VACUUM ALARM AUG 18, 2022 5:47 PM NO VACUUM ALARM 8 ATM 10 FM 13-14 11 FM 15-16 12 FM 17-18 13 FM 19-20 14 FM 21-22 15 FM 23-24 16 PS 17-18 MAY 24, 2023 3:02 PM COMMUNICATION ALARM I40200 JUL 25, 2023 4:21 PM I40300 JUL 25, 2023 4:21 PM I34200 JUL 25, 2023 4:21 PM I34700 JUL 25, 2023 4:21 PM IV0100 JUL 25, 2023 4:21 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-06-19 10:01:26 A/L RATIO DEGRADATION FP22 BLEND3 0.74 23-06-19 10:01:26 A/L RATIO DEGRADATION FP14 BLEND3 0.77 23-06-18 10:01:43 A/L RATIO DEGRADATION FP22 BLEND3 0.77 23-06-18 10:01:43 A/L RATIO DEGRADATION FP14 BLEND3 0.78 23-06-17 10:01:51 A/L RATIO DEGRADATION FP22 BLEND3 0.78 23-06-16 10:01:45 A/L RATIO DEGRADATION FP22 BLEND3 0.79 23-06-15 10:02:20 A/L RATIO DEGRADATION FP22 BLEND3 0.80 23-05-16 10:01:40 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:FM 13-14 23-05-16 10:01:40 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 159.83 23-05-16 10:01:40 A/L RATIO GROSS BLOCKAGE FP14 BLEND3 BLKD FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-01-20 10:02:36 A/L RATIO DEGRADATION FP18 BLEND3 0.72 21-10-27 10:03:09 A/L RATIO GROSS BLOCKAGE FP24 BLEND3 BLKD 20-12-02 10:02:55 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 56.91 19-05-17 08:31:19 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-16 08:31:33 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-15 08:31:32 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-14 08:31:21 SENSOR OUT SELFTEST T 1 19-05-14 08:31:21 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-05-14 08:31:20 SETUP SELFTEST MISSING TANK(S) 19-05-13 08:31:17 SENSOR OUT SELFTEST T 1 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-25 14:16:54 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-25 14:16:54 ISD STARTUP 23-07-25 14:16:44 ISD SHUTDOWN 23-07-19 10:02:36 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-18 14:31:32 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 14:31:32 ISD STARTUP 23-07-18 14:31:06 ISD SHUTDOWN 23-07-17 10:02:31 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-16 15:58:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-16 15:58:51 ISD STARTUP