Loading...
HomeMy WebLinkAboutFMC 2023Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10155793 7/26/2023 Jaco #7705 Fastrip #641 1200 Coffee Road Bakersfield 93308 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 VMI 3924 10/24/2024 GVR ATG B47853 7/30/2024 7/26/2023 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder-Root TLS 350R 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 UNL STP L2 420 UNL ANN L3 208 UNL FILL L4 208 PREM STP C1 208 PREM ANN L6 208 PREM FILL L7 208 DSL STP L8 420 DSL ANN L9 208 DSL FILL L10 208 DISP 1-2 L11 208 DISP 3-4 L12 208 DISP 5-6 L13 208 DISP 7-8 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V UNL T2 FX1V PREM T3 FX1DV DIESEL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. V F L9 L6 L3 STP L1 STP L4 STP L7 L10 L11 L13 L12 1 2 3 4 5 6 7 8 COFFEE RD BRIMHALL RDPROPERTY LINE PROPERTY LINEW G V F V F12,000 GALLON87 UNLEADED 12,000 GALLON91 PREMIUM 12,000 GALLONDIESEL L8 L5 L2 A A A EXISTING BUILDING DUMPSTER NOPARKING PRICE SIGNCATCHBASIN N W H LEGEND L1 87 STP L2 87 ANNULAR L3 87 FILL L4 91 STP L5 91 ANNULAR L6 91 FILL L7 DSL STP L8 DSL ANNULAR L9 DSL FILL L10 UDC 1 - 2 L11 UDC 3 - 4 L12 UDC 5 - 6 L13 UDC 7 - 8 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 3/2 INCH DOUBLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SITE MAP PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FASTRIP #7705 FACILITY ID 15-021-003504 CERS ID 10133029 1200 COFFEE RD. BAKERSFIELD, CA 93308 09/14/16 REV. 1200 COFFEE RD. BAKERSFIELD, CA 93308 SCALE: C1 VICINITY MAP PROJECT DATA 1"=10'-0" INCHES012 SHEET SIZE 22 X 34 BRIMHALL RD.COFFEE RD. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #7705 Fastrip #6411200 Coffee RoadBakersfield101557931/23/4 5/68791Diesel 87918791Diesel 871/21/23/45/65/67/8ProductProductProductProductProductProductProductProductProductAaron Perrigo APPENDIX C-10 7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB917/8ProductAaron Perrigo Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10155793 7/26/2023 Jaco #7705 Fastrip #641 1200 Coffee Road Bakersfield 93308 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 FFS 1010993708 7/10/2024 PEI 1200 Lake Test SPILL BUCKETS x3 7/26/2023 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 PHILTITE T2 PHILTITE T3 PHILTITE Jaco 7705 Setup Responses Received: 200 FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 AUG 2, 2023 12:19 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 2484 28.84 1.1 85.4 9548 2 PREMIUM 7816 68.66 0.0 86.9 4216 3 DIESEL 6589 59.65 1.0 90.0 5443 I90500 AUG 2, 2023 12:19 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 AUG 2, 2023 12:19 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 2, 2023 12:19 PM SHIFT TIME 1 : 11:00 PM I50202 AUG 2, 2023 12:19 PM SHIFT TIME 2 : DISABLED I50203 AUG 2, 2023 12:19 PM SHIFT TIME 3 : DISABLED I50204 AUG 2, 2023 12:19 PM SHIFT TIME 4 : DISABLED I54600 AUG 2, 2023 12:19 PM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 2, 2023 12:19 PM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 2, 2023 12:19 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 2, 2023 12:19 PM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 2, 2023 12:19 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 2, 2023 12:19 PM PRINT TC VOLUMES ENABLED I50E00 AUG 2, 2023 12:19 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 2, 2023 12:19 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 2, 2023 12:19 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 2, 2023 12:19 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 2, 2023 12:19 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 AUG 2, 2023 12:19 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 2, 2023 12:19 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 2, 2023 12:19 PM TANK CHART SECURITY DISABLED I5BD00 AUG 2, 2023 12:19 PM CUSTOM ALARM LABELS DISABLED I56000 AUG 2, 2023 12:19 PM MASS/DENSITY DISABLED I88101 AUG 2, 2023 12:19 PM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 AUG 2, 2023 12:19 PM PORT SETTINGS: COMM BOARD : 2 (EDIM ) RS-232 SECURITY CODE : DISABLED I88103 AUG 2, 2023 12:19 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 AUG 2, 2023 12:19 PM I88105 AUG 2, 2023 12:19 PM I88106 AUG 2, 2023 12:19 PM I52000 AUG 2, 2023 12:19 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE DEC 7, 2010 DISABLED 2 ON DATE DEC 7, 2010 DISABLED 3 ON DATE DEC 7, 2010 DISABLED 4 ON DATE DEC 7, 2010 DISABLED 5 ON DATE DEC 7, 2010 DISABLED 6 ON DATE DEC 7, 2010 DISABLED 7 ON DATE DEC 7, 2010 DISABLED 8 ON DATE DEC 7, 2010 DISABLED I60100 AUG 2, 2023 12:19 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 AUG 2, 2023 12:19 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 AUG 2, 2023 12:19 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 AUG 2, 2023 12:19 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 AUG 2, 2023 12:19 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.00 2 PREMIUM 111.00 3 DIESEL 111.00 4 0.00 I60A00 AUG 2, 2023 12:19 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12032 2 PREMIUM 1 PT 12032 3 DIESEL 1 PT 12032 4 1 PT 0 I60400 AUG 2, 2023 12:19 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 PREMIUM 12032 3 DIESEL 12032 4 0 I60500 AUG 2, 2023 12:19 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 2 PREMIUM 12032 0 0 0 3 DIESEL 12032 0 0 0 4 0 0 0 0 I60600 AUG 2, 2023 12:19 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 PREMIUM 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 2, 2023 12:19 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 AUG 2, 2023 12:19 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 PREMIUM 4.0 IN. 3 DIESEL 4.0 IN. I62700 AUG 2, 2023 12:19 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 I64200 AUG 2, 2023 12:19 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 PREMIUM LOW 3 DIESEL LOW I62400 AUG 2, 2023 12:19 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 AUG 2, 2023 12:19 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 PREMIUM 12032 3 DIESEL 12032 4 0 I62300 AUG 2, 2023 12:19 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10829 2 PREMIUM 10829 3 DIESEL 10829 4 0 I62200 AUG 2, 2023 12:19 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11431 2 PREMIUM 11431 3 DIESEL 11431 4 0 I62900 AUG 2, 2023 12:19 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1805 2 PREMIUM 1805 3 DIESEL 1805 4 0 I62100 AUG 2, 2023 12:19 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 PREMIUM 500 3 DIESEL 500 4 0 I62600 AUG 2, 2023 12:19 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 AUG 2, 2023 12:19 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I60800 AUG 2, 2023 12:19 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 5.40 2 PREMIUM 5.00 3 DIESEL 1.00 4 0.00 I60B00 AUG 2, 2023 12:20 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 2, 2023 12:20 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 AUG 2, 2023 12:20 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 AUG 2, 2023 12:20 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62A00 AUG 2, 2023 12:20 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62C00 AUG 2, 2023 12:20 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 AUG 2, 2023 12:20 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 2, 2023 12:20 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 AUG 2, 2023 12:20 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 AUG 2, 2023 12:20 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 AUG 2, 2023 12:20 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63A00 AUG 2, 2023 12:20 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 AUG 2, 2023 12:20 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 15, 2008 START TIME : 2:00 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 2, 2023 12:20 PM CSLD PROBABLITY OF DETECTION I61400 AUG 2, 2023 12:20 PM CSLD CLIMATE FACTOR I61600 AUG 2, 2023 12:20 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 AUG 2, 2023 12:20 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 AUG 2, 2023 12:20 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 2, 2023 12:20 PM CSLD REPORT ONLY I62B00 AUG 2, 2023 12:20 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 PREMIUM ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 AUG 2, 2023 12:20 PM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 2, 2023 12:20 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 AUG 2, 2023 12:20 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 AUG 2, 2023 12:20 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 AUG 2, 2023 12:20 PM I77700 AUG 2, 2023 12:20 PM I77800 AUG 2, 2023 12:20 PM I78C00 AUG 2, 2023 12:20 PM I78300 AUG 2, 2023 12:20 PM I78F00 AUG 2, 2023 12:20 PM I78700 AUG 2, 2023 12:20 PM I70200 AUG 2, 2023 12:20 PM LIQUID LABEL DEVICE LABEL 1 UNL STP 2 UNL ANN 3 UNL FILL 4 PREM STP 5 PREM ANN 6 PREM FILL 7 DIESEL STP 8 DIESEL ANN 9 DIESEL FILL 10 DISP 1-2 11 DISP 3-4 12 DISP 5-6 13 DISP 7-8 14 15 16 I70300 AUG 2, 2023 12:20 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL STP TRI-STATE (SINGLE FLOAT) 2 UNL ANN TRI-STATE (SINGLE FLOAT) 3 UNL FILL TRI-STATE (SINGLE FLOAT) 4 PREM STP TRI-STATE (SINGLE FLOAT) 5 PREM ANN TRI-STATE (SINGLE FLOAT) 6 PREM FILL TRI-STATE (SINGLE FLOAT) 7 DIESEL STP TRI-STATE (SINGLE FLOAT) 8 DIESEL ANN TRI-STATE (SINGLE FLOAT) 9 DIESEL FILL TRI-STATE (SINGLE FLOAT) 10 DISP 1-2 TRI-STATE (SINGLE FLOAT) 11 DISP 3-4 TRI-STATE (SINGLE FLOAT) 12 DISP 5-6 TRI-STATE (SINGLE FLOAT) 13 DISP 7-8 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 AUG 2, 2023 12:20 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL STP STP SUMP 2 UNL ANN ANNULAR SPACE 3 UNL FILL OTHER SENSORS 4 PREM STP STP SUMP 5 PREM ANN ANNULAR SPACE 6 PREM FILL OTHER SENSORS 7 DIESEL STP STP SUMP 8 DIESEL ANN ANNULAR SPACE 9 DIESEL FILL OTHER SENSORS 10 DISP 1-2 DISPENSER PAN 11 DISP 3-4 DISPENSER PAN 12 DISP 5-6 DISPENSER PAN 13 DISP 7-8 DISPENSER PAN 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 AUG 2, 2023 12:20 PM 2 WIRE CL LABEL DEVICE LABEL 1 PREM ANN 2 3 4 5 6 7 8 I74300 AUG 2, 2023 12:20 PM 2 WIRE CL TYPE SENSOR LOCATION TYPE 1 PREM ANN ULTRA 2 2 ULTRA 2 3 ULTRA 2 4 ULTRA 2 5 ULTRA 2 6 ULTRA 2 7 ULTRA 2 8 ULTRA 2 I74400 AUG 2, 2023 12:20 PM 2 WIRE CL CATEGORY SENSOR LOCATION CATEGORY 1 PREM ANN ANNULAR SPACE 2 OTHER SENSORS 3 OTHER SENSORS 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS I74700 AUG 2, 2023 12:20 PM I74800 AUG 2, 2023 12:20 PM I74900 AUG 2, 2023 12:20 PM I7BC00 AUG 2, 2023 12:20 PM I80200 AUG 2, 2023 12:20 PM I80300 AUG 2, 2023 12:20 PM I80400 AUG 2, 2023 12:20 PM I80700 AUG 2, 2023 12:20 PM RELAY LABEL DEVICE LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 OVERFILL ALARM I80900 AUG 2, 2023 12:20 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED NORMALLY OPEN 2 PREMIUM NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 AUG 2, 2023 12:20 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 OVERFILL ALARM NONE I80A00 AUG 2, 2023 12:20 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED PUMP CONTROL OUTPUT 2 PREMIUM PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 AUG 2, 2023 12:20 PM I80800 AUG 2, 2023 12:20 PM RELAY SETUP REPORT R 1:UNLEADED TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 1:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 1:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PREMIUM TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L 4:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 4:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 4:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 7:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 AUG 2, 2023 12:21 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 2, 2023 12:21 PM I72300 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 P.S.DISP 3-4 VAPOR PRESSURE 02 F.M. DISP 1-2 AIR FLOW METER 03 F.M. DISP 3-4 AIR FLOW METER 04 F.M. DISP 5-6 AIR FLOW METER 05 F.M. DISP 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 VAPOR PROCESSOR TYPE NONE IV4700 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ACCEPT HIGH ORVR: YES IV4A00 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 2, 2023 12:21 PM ISD VERSION: 01.07 Jaco Alarm History Responses Received: I10200 AUG 2, 2023 12:21 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 505479 504728 2 4 PROBE / G.T. 163020 162750 3 INTERSTITIAL BD 201109 200909 4 INTERSTITIAL BD 200615 200393 5 2 WIRE CL 68258 68106 6 UNUSED 9895331 9858119 7 UNUSED 9894485 9846279 8 UNUSED 9884372 9838283 9 STP SENSE BOARD 33099 33072 10 RELAY BOARD 14869 14883 11 UNUSED 9899057 9844615 12 UNUSED 9887313 9836102 13 UNUSED 9880998 9835751 14 UNUSED 9882607 9841826 15 UNUSED 9882938 9832692 16 UNUSED 9882153 9844202 COMM 1 RS232 SERIAL BD 14931 14924 COMM 2 ELEC DISP INT. 100900 100828 COMM 3 RS232 SERIAL BD 14994 14966 COMM 4 UNUSED 9892618 9851682 COMM 5 UNUSED 9888077 9847219 COMM 6 UNUSED 9889006 9842652 I90200 AUG 2, 2023 12:22 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 OTHER PREM FILL FUEL ALARM CLEAR 7-26-23 11:00AM L 6 OTHER PREM FILL FUEL ALARM ALARM 7-26-23 10:57AM L 6 OTHER PREM FILL SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 4 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 3 OTHER UNL FILL SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 2 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 8 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 9 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-26-23 9:51AM C 1 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-26-23 9:51AM L 6 OTHER PREM FILL SENSOR OUT ALARM ALARM 7-26-23 9:51AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-26-23 9:50AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 4 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 3 OTHER UNL FILL SENSOR OUT ALARM ALARM 7-26-23 9:50AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 2 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-26-23 9:50AM C 1 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-26-23 9:50AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 8 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 9 OTHER DIESEL FILL SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 1 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-26-23 9:50AM L 8 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-26-23 9:43AM L 8 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-26-23 9:43AM C 1 ANNULAR PREM ANN FUEL ALARM CLEAR 7-26-23 9:42AM C 1 ANNULAR PREM ANN FUEL ALARM ALARM 7-26-23 9:42AM L 2 ANNULAR UNL ANN FUEL ALARM CLEAR 7-26-23 9:41AM L 2 ANNULAR UNL ANN FUEL ALARM ALARM 7-26-23 9:41AM L 3 OTHER UNL FILL FUEL ALARM CLEAR 7-26-23 9:41AM L 3 OTHER UNL FILL FUEL ALARM ALARM 7-26-23 9:40AM L 6 OTHER PREM FILL FUEL ALARM CLEAR 7-26-23 9:40AM L 6 OTHER PREM FILL FUEL ALARM ALARM 7-26-23 9:40AM L 9 OTHER DIESEL FILL FUEL ALARM CLEAR 7-26-23 9:39AM L 9 OTHER DIESEL FILL FUEL ALARM ALARM 7-26-23 9:39AM L 7 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-26-23 9:39AM L 7 STP SUMP DIESEL STP FUEL ALARM ALARM 7-26-23 9:39AM L 4 STP SUMP PREM STP FUEL ALARM CLEAR 7-26-23 9:38AM L 4 STP SUMP PREM STP FUEL ALARM ALARM 7-26-23 9:38AM L 1 STP SUMP UNL STP FUEL ALARM CLEAR 7-26-23 9:38AM L 1 STP SUMP UNL STP FUEL ALARM ALARM 7-26-23 9:38AM L11 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-26-23 9:37AM L11 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-26-23 9:37AM L13 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-26-23 9:36AM L13 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-26-23 9:36AM I11200 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-29-23 6:43PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-29-23 4:27PM SYSTEM PRINTER ERROR CLEAR 7-27-23 11:51AM SYSTEM PAPER OUT CLEAR 7-27-23 11:51AM SYSTEM PRINTER ERROR ALARM 7-27-23 11:51AM SYSTEM PAPER OUT ALARM 7-27-23 11:51AM SYSTEM PRINTER ERROR CLEAR 7-27-23 11:50AM SYSTEM PAPER OUT CLEAR 7-27-23 11:50AM SYSTEM PRINTER ERROR ALARM 7-27-23 11:50AM SYSTEM PAPER OUT ALARM 7-27-23 11:50AM SYSTEM PRINTER ERROR CLEAR 7-27-23 11:43AM SYSTEM PAPER OUT CLEAR 7-27-23 11:43AM SYSTEM PRINTER ERROR ALARM 7-27-23 11:43AM SYSTEM PAPER OUT ALARM 7-27-23 11:43AM SYSTEM PRINTER ERROR CLEAR 7-27-23 11:42AM SYSTEM PAPER OUT CLEAR 7-27-23 11:42AM SYSTEM PRINTER ERROR ALARM 7-27-23 11:41AM SYSTEM PAPER OUT ALARM 7-27-23 11:41AM SYSTEM PRINTER ERROR CLEAR 7-27-23 11:36AM SYSTEM PAPER OUT CLEAR 7-27-23 11:36AM SYSTEM PRINTER ERROR ALARM 7-27-23 11:36AM SYSTEM PAPER OUT ALARM 7-27-23 11:36AM SYSTEM PRINTER ERROR CLEAR 7-27-23 11:36AM SYSTEM PAPER OUT CLEAR 7-27-23 11:36AM SYSTEM PRINTER ERROR ALARM 7-27-23 11:35AM SYSTEM PAPER OUT ALARM 7-27-23 11:35AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-17-23 2:00PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-17-23 1:03PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-14-23 4:09PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-14-23 3:48PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-12-23 1:22PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-12-23 1:08PM SYSTEM PRINTER ERROR CLEAR 7-11-23 6:52AM SYSTEM PAPER OUT CLEAR 7-11-23 6:52AM SYSTEM PRINTER ERROR ALARM 7-11-23 6:52AM SYSTEM PAPER OUT ALARM 7-11-23 6:52AM SYSTEM PRINTER ERROR CLEAR 7-11-23 6:51AM SYSTEM PAPER OUT CLEAR 7-11-23 6:51AM SYSTEM PRINTER ERROR ALARM 7-11-23 2:51AM SYSTEM PAPER OUT ALARM 7-11-23 2:51AM SYSTEM PRINTER ERROR CLEAR 7-11-23 2:51AM SYSTEM PAPER OUT CLEAR 7-11-23 2:51AM SYSTEM PRINTER ERROR ALARM 7-11-23 2:50AM SYSTEM PAPER OUT ALARM 7-11-23 2:50AM SYSTEM PRINTER ERROR CLEAR 7-11-23 2:50AM SYSTEM PAPER OUT CLEAR 7-11-23 2:50AM SYSTEM PRINTER ERROR ALARM 7-11-23 1:43AM SYSTEM PAPER OUT ALARM 7-11-23 1:43AM SYSTEM PRINTER ERROR CLEAR 7-11-23 1:43AM SYSTEM PAPER OUT CLEAR 7-11-23 1:43AM I20600 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUN 9, 2023 12:36 AM MAR 31, 2023 1:43 AM MAR 25, 2023 11:29 AM INVALID FUEL LEVEL APR 26, 2023 6:39 PM MAR 9, 2023 5:18 PM JAN 12, 2023 1:52 PM DELIVERY NEEDED JUL 29, 2023 4:27 PM JUL 17, 2023 1:03 PM JUL 14, 2023 3:48 PM TANK 2 PREMIUM OVERFILL ALARM FEB 22, 2023 5:14 AM DEC 27, 2022 8:16 PM JUN 26, 2022 1:25 PM SUDDEN LOSS ALARM MAY 1, 2023 3:19 PM TANK 3 DIESEL DELIVERY NEEDED JUL 26, 2022 3:21 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 2, 2023 12:22 PM I30200 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:38 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 2 UNL ANN JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:41 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 3 UNL FILL JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:40 AM FUEL ALARM JUL 3, 2023 2:00 PM FUEL ALARM 4 PREM STP JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:38 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 6 PREM FILL JUL 26, 2023 10:57 AM FUEL ALARM JUL 26, 2023 9:51 AM SENSOR OUT ALARM JUL 26, 2023 9:40 AM FUEL ALARM 7 DIESEL STP JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:39 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 8 DIESEL ANN JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:43 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 9 DIESEL FILL JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:39 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 10 DISP 1-2 JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:35 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 11 DISP 3-4 JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:37 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 12 DISP 5-6 JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:36 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM 13 DISP 7-8 JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:36 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM I31600 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 P.S.DISP 3-4 2 F.M. DISP 1-2 3 F.M. DISP 3-4 4 F.M. DISP 5-6 5 F.M. DISP 7-8 I40200 AUG 2, 2023 12:22 PM I40300 AUG 2, 2023 12:22 PM I34200 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 2 WIRE CL ALARM HISTORY REPORT SENSOR LOCATION 1 PREM ANN JUL 26, 2023 9:50 AM SENSOR OUT ALARM JUL 26, 2023 9:42 AM FUEL ALARM JUL 3, 2023 2:00 PM SENSOR OUT ALARM I34700 AUG 2, 2023 12:22 PM IV0100 AUG 2, 2023 12:22 PM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-06-26 10:02:38 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 23-06-16 10:02:34 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 23-05-25 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-24 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-23 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-22 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-21 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-20 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-19 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-12 10:01:09 VAPOR CONTAINMENT LEAKAGE GROSS FAIL FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-05-26 10:02:21 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 23-05-01 10:02:06 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 23-04-30 10:02:10 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 23-04-29 10:01:57 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 23-04-08 10:02:18 A/L RATIO DEGRADATION FP 8 BLEND3 0.78 23-03-08 10:02:05 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 23-03-07 10:01:49 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 22-10-23 10:02:24 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-10-23 10:02:24 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-11-02 10:03:20 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-26 10:03:07 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-26 09:50:01 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-26 09:50:01 ISD STARTUP 23-07-26 09:49:32 ISD SHUTDOWN 23-07-16 10:02:54 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-16 09:50:04 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-16 09:50:04 ISD STARTUP 23-07-16 09:49:53 ISD SHUTDOWN 23-07-06 10:03:46 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-05 10:03:44 READINESS ISD:PP EVR:NP EVR READINESS PENDING