HomeMy WebLinkAboutFMC 2023Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10159083 7/24/23 Jaco #7775 Fastrip #19 (North) 4901 South Union Avenue Bakersfield 93307 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Payton Phillips 1073967 9482312 01/15/2024 Veeder Root C27796 08/01/2024 7/24/23 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veedor Root TLS-350 334.00 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 UNL 1 STP UNL 1 STP L3 UNL 2 STP UNL 2 STP L4 420 UNL 2 Ann L5 208 PNL STP L6 420 PNL Ann L7 208 DSL STP L8 420 DSL Ann L9 208 Disp 1-2 L10 208 Disp 3-4 L11 208 Disp 5-6 L12 208 Disp 7-8 L13 208 N. Trans Sump L14 208 S. Trans Sump L15 420 UNL 1 Ann Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V Unleaded 1 T3 FX1V Premium T4 VMI Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 12,000 GALLON12,000 GALLONEXISTING BUILDING NOPAR KI NG G W PRICE SIGNPRICE SIGN12,000 GALLON87-1 UNLEADEDFV STPL5H HDUMPSTER FFVSTPL3STPL1AL6AL4AL212,000 GALLONDIESEL87 UNLEADEDPREMIUM1112L81516L10910L71314L9#7-725FSTPL1V AL8 AL6 AL4 AL2 FSTPL3V FSTPL5V FSTPL7 12,000 GALLON87-2 UNLEADED 12,000 GALLONPREMIUM 12,000 GALLONDIESEL 21L9 43L10 L14 65L11 87L12 L13 40' STORAGE CONTAINER 40' STORAGE CONTAINER S. UNION AVE.PACHECO RD.N #7-775 7-775 7-725 SLOPE PROPERTY LINE PROPERTY LINE ADJACENT JACO PORPERTY TO THE SOUTH NOT SHOWN, FOR CLARITY PROPANE TANK CAGE 167.17' 148.17' 315.86'108.70'63.50'172.22' EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G H 725 LEGEND L1 87 STP L2 87 ANNULAR L3 91 STP L4 91 ANNULAR L5 DSL STP L6 DSL ANNULAR L7 UDC 9 -10 L8 UDC 11 - 12 L9 UDC 13 - 14 L10 UDC 15 - 16 775 LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 87-2 STP L4 87-2 ANNULAR L5 91 STP L6 91 ANNULAR L7 DSL STP L8 DSL ANNULAR L9 UDC 1 -2 L10 UDC 3 - 4 L11 UDC 5 -6 L12 UDC 7 - 8 L13 N TRANS SUMP L14 S TRANS SUMP 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 3/2 INCH DOUBLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULARA P V SITE MAP SCALE: C1 VICINITY MAP PROJECT DATA 1"=15'-0" INCHES012 SHEET SIZE 22 X 34 4901 S. UNION AVE. BAKERSFIELD, CA 93307 PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FASTRIPS #7725 / #7775 #7725 CERS ID 10159083 FACILITY ID 15-021-100269 #7775 CERS ID 10159109 FACILITY ID 15-021-003076 4901 S. UNION AVE. BAKERSFIELD, CA 93307 03/06/17 REV.S. UNION AVE.E. PACHECO RD. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #7775 Fastrip #19 (North)4901 South Union AvenueBakersfield101590833/47/8ESO passed also.MPDMPDMPDMPD1/25/6ProductProductProductProductPayton Phillips Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10159083 7/24/23 Jaco #7775 Fastrip #19 (North) 4901 South Union Avenue Bakersfield 93307 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Payton Phillips 1073967 9482312 01/15/2024 OPW 0187328 08/14/2024 PEI 1200 OPW Spill buckets 7/24/23 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 UNL 1 OPW T2 UNL 2 OPW T3 PNL OPW T4 DSL OPW 7.24.23 Jaco 7775 Monitor Cert Testing Printouts System Set up Responses Received: 200 FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 JUL 24, 2023 12:55 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 1 7540 57.61 0.0 87.1 4492 2 UNLEADED 2 7997 60.56 0.0 85.3 4035 3 PREMIUM 6038 48.14 0.9 86.7 5993 4 DIESEL 9349 69.64 0.0 87.6 2683 I90500 JUL 24, 2023 12:55 PM SOFTWARE REVISION LEVEL VERSION 334.00 SOFTWARE# 346334-100-A CREATED - 15.05.29.10.36 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 24, 2023 12:55 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 24, 2023 12:55 PM SHIFT TIME 1 : 6:00 AM I50202 JUL 24, 2023 12:55 PM SHIFT TIME 2 : DISABLED I50203 JUL 24, 2023 12:55 PM SHIFT TIME 3 : DISABLED I50204 JUL 24, 2023 12:55 PM SHIFT TIME 4 : DISABLED I54600 JUL 24, 2023 12:55 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 24, 2023 12:55 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 24, 2023 12:55 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 24, 2023 12:55 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 24, 2023 12:55 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 24, 2023 12:55 PM PRINT TC VOLUMES ENABLED I50E00 JUL 24, 2023 12:55 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 24, 2023 12:55 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 24, 2023 12:55 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 24, 2023 12:55 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 24, 2023 12:55 PM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 JUL 24, 2023 12:55 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 24, 2023 12:55 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 24, 2023 12:55 PM TANK CHART SECURITY DISABLED I5BD00 JUL 24, 2023 12:55 PM CUSTOM ALARM LABELS DISABLED I56000 JUL 24, 2023 12:55 PM MASS/DENSITY DISABLED I88101 JUL 24, 2023 12:55 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 24, 2023 12:55 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 24, 2023 12:55 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 24, 2023 12:55 PM I88105 JUL 24, 2023 12:55 PM I88106 JUL 24, 2023 12:55 PM I52000 JUL 24, 2023 12:55 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE APR 8, 2016 DISABLED 2 ON DATE APR 8, 2016 DISABLED 3 ON DATE APR 8, 2016 DISABLED 4 ON DATE APR 8, 2016 DISABLED 5 ON DATE APR 8, 2016 DISABLED 6 ON DATE APR 8, 2016 DISABLED 7 ON DATE APR 8, 2016 DISABLED 8 ON DATE APR 8, 2016 DISABLED I60100 JUL 24, 2023 12:55 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED 1 ON 2 UNLEADED 2 ON 3 PREMIUM ON 4 DIESEL ON I60200 JUL 24, 2023 12:55 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 3 PREMIUM 4 DIESEL I60300 JUL 24, 2023 12:55 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 1 2 UNLEADED 2 2 3 PREMIUM 3 4 DIESEL 4 I60900 JUL 24, 2023 12:55 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 1 0.000700 2 UNLEADED 2 0.000700 3 PREMIUM 0.000700 4 DIESEL 0.000450 I60700 JUL 24, 2023 12:55 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 1 96.00 2 UNLEADED 2 96.00 3 PREMIUM 96.00 4 DIESEL 96.00 I60A00 JUL 24, 2023 12:55 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 1 PT 12032 2 UNLEADED 2 1 PT 12032 3 PREMIUM 1 PT 12031 4 DIESEL 1 PT 12032 I60400 JUL 24, 2023 12:55 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 12032 2 UNLEADED 2 12032 3 PREMIUM 12031 4 DIESEL 12032 I60500 JUL 24, 2023 12:55 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 12032 0 0 0 2 UNLEADED 2 12032 0 0 0 3 PREMIUM 12031 0 0 0 4 DIESEL 12032 0 0 0 I60600 JUL 24, 2023 12:55 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNLEADED 2 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12031 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 24, 2023 12:55 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED 1 NO 2 UNLEADED 2 NO 3 PREMIUM NO 4 DIESEL NO I62F00 JUL 24, 2023 12:55 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 1 4.0 IN. 2 UNLEADED 2 4.0 IN. 3 PREMIUM 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 24, 2023 12:56 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 1 2.0 2 UNLEADED 2 2.0 3 PREMIUM 2.0 4 DIESEL 2.0 I64200 JUL 24, 2023 12:56 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED 1 LOW 2 UNLEADED 2 LOW 3 PREMIUM LOW 4 DIESEL LOW I62400 JUL 24, 2023 12:56 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 1 3.0 2 UNLEADED 2 3.0 3 PREMIUM 3.0 4 DIESEL 3.0 I62800 JUL 24, 2023 12:56 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 12032 2 UNLEADED 2 12032 3 PREMIUM 12031 4 DIESEL 12032 I62300 JUL 24, 2023 12:56 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 10829 2 UNLEADED 2 10829 3 PREMIUM 10828 4 DIESEL 10829 I62200 JUL 24, 2023 12:56 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 11430 2 UNLEADED 2 11430 3 PREMIUM 11429 4 DIESEL 11430 I62900 JUL 24, 2023 12:56 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 1805 2 UNLEADED 2 1805 3 PREMIUM 1805 4 DIESEL 1805 I62100 JUL 24, 2023 12:56 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 500 2 UNLEADED 2 500 3 PREMIUM 500 4 DIESEL 500 I62600 JUL 24, 2023 12:56 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I62500 JUL 24, 2023 12:56 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I60800 JUL 24, 2023 12:56 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 1 7.33 2 UNLEADED 2 9.88 3 PREMIUM 2.67 4 DIESEL 3.75 I60B00 JUL 24, 2023 12:56 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 24, 2023 12:56 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 1 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I61200 JUL 24, 2023 12:56 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED 1 2 NONE 2 UNLEADED 2 1 NONE 3 PREMIUM NONE NONE 4 DIESEL NONE NONE I63600 JUL 24, 2023 12:56 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62A00 JUL 24, 2023 12:56 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62C00 JUL 24, 2023 12:56 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED 1 STANDARD 2 UNLEADED 2 STANDARD 3 PREMIUM STANDARD 4 DIESEL STANDARD I62D00 JUL 24, 2023 12:56 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 24, 2023 12:56 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED 1 OFF OFF 2 UNLEADED 2 OFF OFF 3 PREMIUM OFF OFF 4 DIESEL OFF OFF I63000 JUL 24, 2023 12:56 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED 1 OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I63200 JUL 24, 2023 12:56 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED 1 OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I61000 JUL 24, 2023 12:56 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63A00 JUL 24, 2023 12:56 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 1 10.00% 2 UNLEADED 2 10.00% 3 PREMIUM 10.00% 4 DIESEL 10.00% I61100 JUL 24, 2023 12:56 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK APR 8, 2016 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 24, 2023 12:56 PM CSLD PROBABLITY OF DETECTION I61400 JUL 24, 2023 12:56 PM CSLD CLIMATE FACTOR I61600 JUL 24, 2023 12:56 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED 1 IMMEDIATE 2 UNLEADED 2 IMMEDIATE 3 PREMIUM IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 24, 2023 12:56 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED 1 DISABLED 2 UNLEADED 2 DISABLED 3 PREMIUM DISABLED 4 DIESEL DISABLED I61B00 JUL 24, 2023 12:56 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 24, 2023 12:56 PM CSLD REPORT ONLY I62B00 JUL 24, 2023 12:56 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 1 ??? 0, 0 2 UNLEADED 2 ??? 0, 0 3 PREMIUM ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 24, 2023 12:56 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 24, 2023 12:56 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 0 2 UNLEADED 2 0 3 PREMIUM 0 4 DIESEL 0 I63500 JUL 24, 2023 12:56 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63900 JUL 24, 2023 12:56 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED 1 END FACTOR: NONE 2 UNLEADED 2 END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 24, 2023 12:56 PM I77700 JUL 24, 2023 12:56 PM I77800 JUL 24, 2023 12:56 PM I78C00 JUL 24, 2023 12:56 PM I78300 JUL 24, 2023 12:56 PM I78F00 JUL 24, 2023 12:56 PM I78700 JUL 24, 2023 12:56 PM I70200 JUL 24, 2023 12:56 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 UNL 2 STP 4 UNL 2 ANN 5 PNL STP 6 PNL ANN 7 DSL STP 8 DSL ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 N. TRANS SUMP 14 S. TRANS SUMP 15 UNL 1ANN 16 I70300 JUL 24, 2023 12:56 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 UNL 2 STP TRI-STATE (SINGLE FLOAT) 4 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 5 PNL STP TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 DSL STP TRI-STATE (SINGLE FLOAT) 8 DSL ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 N. TRANS SUMP TRI-STATE (SINGLE FLOAT) 14 S. TRANS SUMP TRI-STATE (SINGLE FLOAT) 15 UNL 1ANN TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 24, 2023 12:56 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN ANNULAR SPACE 3 UNL 2 STP STP SUMP 4 UNL 2 ANN ANNULAR SPACE 5 PNL STP STP SUMP 6 PNL ANN ANNULAR SPACE 7 DSL STP STP SUMP 8 DSL ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 OTHER SENSORS 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 N. TRANS SUMP PIPING SUMP 14 S. TRANS SUMP PIPING SUMP 15 UNL 1ANN ANNULAR SPACE 16 OTHER SENSORS I74200 JUL 24, 2023 12:56 PM I74300 JUL 24, 2023 12:56 PM I74400 JUL 24, 2023 12:56 PM I74700 JUL 24, 2023 12:56 PM I74800 JUL 24, 2023 12:56 PM I74900 JUL 24, 2023 12:56 PM I7BC00 JUL 24, 2023 12:56 PM I80200 JUL 24, 2023 12:56 PM I80300 JUL 24, 2023 12:56 PM I80400 JUL 24, 2023 12:56 PM I80700 JUL 24, 2023 12:56 PM RELAY LABEL DEVICE LABEL 1 OVERFILL 2 OVERFILL 3 PNL 4 5 UNL 1 6 PNL 7 DSL 8 I80900 JUL 24, 2023 12:56 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 OVERFILL NORMALLY OPEN 2 OVERFILL NORMALLY OPEN 3 PNL NORMALLY CLOSED 4 NORMALLY OPEN 5 UNL 1 NORMALLY CLOSED 6 PNL NORMALLY CLOSED 7 DSL NORMALLY CLOSED 8 NORMALLY OPEN I80B00 JUL 24, 2023 12:56 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 OVERFILL NONE 2 OVERFILL NONE 3 PNL NONE 4 NONE 5 UNL 1 1 6 PNL NONE 7 DSL NONE 8 NONE I80A00 JUL 24, 2023 12:56 PM RELAY TYPE RELAY DESIGNATION TYPE 1 OVERFILL STANDARD 2 OVERFILL STANDARD 3 PNL STANDARD 4 STANDARD 5 UNL 1 STANDARD 6 PNL STANDARD 7 DSL STANDARD 8 STANDARD I80C00 JUL 24, 2023 12:56 PM I80800 JUL 24, 2023 12:56 PM RELAY SETUP REPORT R 1:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM R 2:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM R 3:PNL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:UNL 1 TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL R 6:PNL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL R 7:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 JUL 24, 2023 12:57 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 24, 2023 12:57 PM I72300 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 3-4 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 VAPOR PROCESSOR TYPE NONE IV4700 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 ASSESSMENT TIME START TIME: 10:09 AM TIME DELAY MINUTES: 1 IV5200 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 ACCEPT HIGH ORVR: YES IV4A00 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 07 BLEND3 02 02 02 01 07 BLEND3 03 03 03 02 07 BLEND3 04 04 04 02 07 BLEND3 05 05 05 03 07 BLEND3 06 06 06 03 07 BLEND3 07 07 07 04 07 BLEND3 08 08 08 04 07 BLEND3 IV4B00 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 03/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JUL 24, 2023 12:57 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 24, 2023 12:57 PM ISD VERSION: 01.05 Alarm history (Before) I10200 JUL 24, 2023 12:59 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39334 39098 2 4 PROBE / G.T. 163624 162719 3 INTERSTITIAL BD 202241 201505 4 INTERSTITIAL BD 201618 201134 5 UNUSED 10065686 9846855 6 UNUSED 10026804 9842444 7 UNUSED 10019950 9836006 8 UNUSED 10013054 9828186 9 RELAY BOARD 14936 14917 10 RELAY BOARD 14957 14940 11 UNUSED 10031584 9839545 12 UNUSED 10015933 9829342 13 UNUSED 10001969 9832550 14 UNUSED 10004553 9839122 15 UNUSED 10003934 9834934 16 UNUSED 9996247 9827003 COMM 1 ELEC DISP INT. 101008 100910 COMM 2 RS232 SERIAL BD 15000 14984 COMM 3 RS232 SERIAL BD 14936 14895 COMM 4 UNUSED 10014994 9845516 COMM 5 UNUSED 10008845 9841127 COMM 6 UNUSED 10002439 9829543 I90200 JUL 24, 2023 1:00 PM SOFTWARE REVISION LEVEL VERSION 334.00 SOFTWARE# 346334-100-A CREATED - 15.05.29.10.36 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 24, 2023 1:00 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNLEADED 2 OVERFILL ALARM CLEAR 7-20-23 2:14AM T 2 TANK UNLEADED 2 OVERFILL ALARM ALARM 7-20-23 2:06AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-18-23 10:41AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-18-23 10:41AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-18-23 10:40AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-18-23 10:40AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-18-23 10:39AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-18-23 10:39AM L10 OTHER DISP 3-4 FUEL ALARM CLEAR 7-18-23 10:38AM L10 OTHER DISP 3-4 FUEL ALARM ALARM 7-18-23 10:37AM L 7 STP SUMP DSL STP FUEL ALARM CLEAR 7-18-23 10:36AM L 7 STP SUMP DSL STP FUEL ALARM ALARM 7-18-23 10:36AM L 5 STP SUMP PNL STP FUEL ALARM CLEAR 7-18-23 10:36AM L 5 STP SUMP PNL STP FUEL ALARM ALARM 7-18-23 10:36AM L 3 STP SUMP UNL 2 STP FUEL ALARM CLEAR 7-18-23 10:35AM L 3 STP SUMP UNL 2 STP FUEL ALARM ALARM 7-18-23 10:35AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-18-23 10:35AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-18-23 10:35AM L 8 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 7 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 3 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L15 ANNULAR UNL 1ANN SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L14 PIPE S. TRANS SUMP SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L10 OTHER DISP 3-4 SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L13 PIPE N. TRANS SUMP SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-18-23 10:30AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-18-23 10:30AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-18-23 10:30AM L10 OTHER DISP 3-4 SENSOR OUT ALARM ALARM 7-18-23 10:30AM L15 ANNULAR UNL 1ANN SENSOR OUT ALARM ALARM 7-18-23 10:30AM L14 PIPE S. TRANS SUMP SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 3 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 8 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 7 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-18-23 10:30AM L13 PIPE N. TRANS SUMP SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-18-23 10:30AM L 5 STP SUMP PNL STP SENSOR OUT ALARM ALARM 7-18-23 10:30AM L13 PIPE N. TRANS SUMP FUEL ALARM CLEAR 7-18-23 10:29AM L13 PIPE N. TRANS SUMP FUEL ALARM ALARM 7-18-23 10:29AM L14 PIPE S. TRANS SUMP FUEL ALARM CLEAR 7-18-23 10:29AM L14 PIPE S. TRANS SUMP FUEL ALARM ALARM 7-18-23 10:29AM I11200 JUL 24, 2023 1:00 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT ALARM 7-22-23 12:41AM SYSTEM PAPER OUT CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT ALARM 7-22-23 12:41AM SYSTEM PAPER OUT CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT ALARM 7-22-23 12:41AM SYSTEM PRINTER ERROR ALARM 7-22-23 12:41AM L 2 ANNULAR UNL 1 ANN SETUP DATA WARNING CLEAR 7-18-23 10:28AM L 2 ANNULAR UNL 1 ANN SETUP DATA WARNING ALARM 7-18-23 10:27AM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:47PM SYSTEM PAPER OUT CLEAR 7-05-23 3:47PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:47PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:47PM SYSTEM PAPER OUT ALARM 7-05-23 3:46PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:46PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:46PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:46PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:45PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:45PM SYSTEM PAPER OUT CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:45PM SYSTEM PAPER OUT ALARM 7-05-23 3:45PM SYSTEM PAPER OUT CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:45PM SYSTEM PAPER OUT ALARM 7-05-23 3:44PM SYSTEM PRINTER ERROR CLEAR 6-24-23 8:55AM SYSTEM PAPER OUT CLEAR 6-24-23 8:55AM SYSTEM PRINTER ERROR ALARM 6-24-23 8:55AM SYSTEM PRINTER ERROR CLEAR 6-24-23 8:55AM SYSTEM PAPER OUT ALARM 6-24-23 8:55AM SYSTEM PRINTER ERROR ALARM 6-24-23 8:55AM SYSTEM PRINTER ERROR CLEAR 6-22-23 9:24AM SYSTEM PAPER OUT CLEAR 6-22-23 9:24AM SYSTEM PAPER OUT ALARM 6-22-23 9:24AM SYSTEM PRINTER ERROR ALARM 6-22-23 9:24AM SYSTEM PRINTER ERROR CLEAR 6-20-23 2:54PM SYSTEM PRINTER ERROR ALARM 6-20-23 2:54PM SYSTEM PRINTER ERROR CLEAR 6-20-23 2:54PM SYSTEM PAPER OUT CLEAR 6-20-23 2:54PM SYSTEM PAPER OUT ALARM 6-20-23 2:54PM SYSTEM PAPER OUT CLEAR 6-20-23 2:54PM SYSTEM PAPER OUT ALARM 6-20-23 2:53PM SYSTEM PRINTER ERROR ALARM 6-20-23 2:49PM SYSTEM PRINTER ERROR CLEAR 6-20-23 2:43PM SYSTEM PRINTER ERROR ALARM 6-20-23 2:43PM SYSTEM PAPER OUT CLEAR 6-20-23 2:43PM SYSTEM PAPER OUT ALARM 6-20-23 2:40PM I20600 JUL 24, 2023 1:00 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 TANK ALARM HISTORY TANK 1 UNLEADED 1 HIGH WATER ALARM JUN 3, 2016 1:07 PM OVERFILL ALARM JUL 3, 2023 9:46 PM JUL 3, 2023 10:35 AM MAY 4, 2023 2:16 AM HIGH PRODUCT ALARM JUL 23, 2020 1:13 PM JUL 5, 2018 2:13 PM JUN 27, 2018 9:36 AM INVALID FUEL LEVEL APR 29, 2023 5:18 PM APR 18, 2021 11:32 AM MAY 5, 2020 12:55 PM PROBE OUT JUL 5, 2018 2:14 PM JUL 5, 2018 2:08 PM JUN 27, 2018 9:37 AM HIGH WATER WARNING JUN 3, 2016 1:07 PM DELIVERY NEEDED APR 29, 2023 4:02 PM APR 19, 2021 9:21 AM APR 18, 2021 10:10 AM MAX PRODUCT ALARM JUL 23, 2020 1:13 PM JUL 5, 2017 11:05 AM LOW TEMP WARNING JUN 27, 2018 9:37 AM JUN 27, 2016 2:06 PM TANK 2 UNLEADED 2 HIGH WATER ALARM JUL 6, 2016 3:55 PM JUL 6, 2016 3:42 PM JUL 6, 2016 3:30 PM OVERFILL ALARM JUL 20, 2023 2:06 AM JUN 29, 2023 7:55 AM JUN 22, 2023 2:36 AM HIGH PRODUCT ALARM JUL 23, 2020 1:14 PM JAN 17, 2020 7:51 AM JUL 5, 2018 2:12 PM INVALID FUEL LEVEL JUL 5, 2017 10:32 AM JUL 6, 2016 2:45 PM JUN 27, 2016 3:36 PM PROBE OUT JUL 5, 2018 2:12 PM JUL 5, 2018 2:07 PM JUN 27, 2018 9:40 AM HIGH WATER WARNING JUL 6, 2016 3:55 PM JUL 6, 2016 3:42 PM JUL 6, 2016 3:30 PM DELIVERY NEEDED APR 23, 2020 12:20 PM JUL 5, 2017 10:32 AM JUL 6, 2016 2:45 PM MAX PRODUCT ALARM JUL 23, 2020 1:14 PM JUL 5, 2017 11:03 AM JUL 6, 2016 3:31 PM LOW TEMP WARNING JUL 5, 2018 2:13 PM JUN 27, 2018 9:41 AM JUL 18, 2016 5:14 PM TANK 3 PREMIUM HIGH WATER ALARM OCT 27, 2016 11:23 AM OVERFILL ALARM JUN 30, 2022 6:11 AM MAY 15, 2018 10:54 AM JUN 28, 2017 10:56 AM HIGH PRODUCT ALARM JUL 23, 2020 1:15 PM JUL 5, 2018 2:11 PM JUN 27, 2018 9:31 AM INVALID FUEL LEVEL AUG 20, 2018 1:42 PM AUG 18, 2018 10:34 AM JUN 27, 2018 9:32 AM PROBE OUT JUL 5, 2018 2:11 PM JUL 5, 2018 2:06 PM JUN 27, 2018 9:32 AM HIGH WATER WARNING OCT 27, 2016 11:23 AM DELIVERY NEEDED DEC 19, 2022 10:48 PM MAR 21, 2019 1:52 PM AUG 19, 2018 9:03 AM MAX PRODUCT ALARM JUL 23, 2020 1:15 PM LOW TEMP WARNING OCT 27, 2016 11:43 AM OCT 27, 2016 11:35 AM JUL 18, 2016 5:39 PM TANK 4 DIESEL OVERFILL ALARM JUL 5, 2017 11:00 AM JUN 28, 2017 10:57 AM HIGH PRODUCT ALARM JUL 23, 2020 1:15 PM JUL 5, 2018 2:09 PM JUN 27, 2018 9:30 AM INVALID FUEL LEVEL NOV 30, 2022 5:03 PM NOV 29, 2022 2:57 PM JAN 24, 2022 8:07 AM PROBE OUT JUN 28, 2021 9:54 AM JUL 5, 2018 2:10 PM JUL 5, 2018 2:05 PM DELIVERY NEEDED JUN 17, 2023 3:53 PM MAR 27, 2023 3:32 PM NOV 30, 2022 2:22 PM MAX PRODUCT ALARM JUL 23, 2020 1:15 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 24, 2023 1:00 PM I30200 JUL 24, 2023 1:00 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 18, 2023 10:35 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM MAR 29, 2023 3:38 AM FUEL ALARM 3 UNL 2 STP JUL 18, 2023 10:35 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM DEC 9, 2022 10:00 AM FUEL ALARM 4 UNL 2 ANN JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 18, 2023 10:22 AM FUEL ALARM DEC 9, 2022 10:08 AM FUEL ALARM 5 PNL STP JUL 18, 2023 10:36 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 17, 2023 6:04 PM FUEL ALARM 6 PNL ANN JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 18, 2023 10:21 AM FUEL ALARM DEC 9, 2022 10:08 AM FUEL ALARM 7 DSL STP JUL 18, 2023 10:36 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUN 6, 2023 8:37 PM FUEL ALARM 8 DSL ANN JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 18, 2023 10:21 AM FUEL ALARM JUL 21, 2022 9:59 AM SENSOR OUT ALARM 9 DISP 1-2 JUL 18, 2023 10:39 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM DEC 9, 2022 10:04 AM FUEL ALARM 10 DISP 3-4 JUL 18, 2023 10:37 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM DEC 9, 2022 10:05 AM FUEL ALARM 11 DISP 5-6 JUL 18, 2023 10:40 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM DEC 9, 2022 10:02 AM FUEL ALARM 12 DISP 7-8 JUL 18, 2023 10:41 AM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM DEC 9, 2022 10:06 AM FUEL ALARM 13 N. TRANS SUMP JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 18, 2023 10:29 AM FUEL ALARM DEC 9, 2022 10:01 AM FUEL ALARM 14 S. TRANS SUMP JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 18, 2023 10:29 AM FUEL ALARM DEC 9, 2022 10:02 AM FUEL ALARM 15 UNL 1ANN JUL 18, 2023 10:30 AM SENSOR OUT ALARM JUL 18, 2023 10:28 AM FUEL ALARM JUL 21, 2022 10:00 AM SENSOR OUT ALARM I31600 JUL 24, 2023 1:00 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 DEC 13, 2021 6:46 PM COMMUNICATION ALARM APR 23, 2017 12:48 PM COMMUNICATION ALARM APR 8, 2016 4:33 PM COMMUNICATION ALARM 2 FM 1-2 APR 14, 2022 5:09 PM COMMUNICATION ALARM APR 14, 2022 3:29 PM COMMUNICATION ALARM APR 13, 2022 7:32 PM COMMUNICATION ALARM 3 FM 3-4 APR 8, 2016 4:33 PM COMMUNICATION ALARM 4 FM 5-6 APR 8, 2016 4:33 PM COMMUNICATION ALARM 5 FM 7-8 APR 8, 2016 4:34 PM COMMUNICATION ALARM I40200 JUL 24, 2023 1:00 PM I40300 JUL 24, 2023 1:00 PM I34200 JUL 24, 2023 1:00 PM I34700 JUL 24, 2023 1:00 PM IV0100 JUL 24, 2023 1:00 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-04-16 10:10:20 A/L RATIO DEGRADATION FP 6 BLEND3 BLKD 23-04-16 10:10:20 A/L RATIO DEGRADATION FP 5 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO DEGRADATION FP 6 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO DEGRADATION FP 5 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-04-14 10:10:09 A/L RATIO DEGRADATION FP 6 BLEND3 BLKD 23-04-14 10:10:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 22-11-30 10:10:44 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.00 22-11-29 10:10:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.00 22-11-28 10:10:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.00 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-04-16 10:10:20 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 23-04-16 10:10:20 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 22-10-05 10:10:50 A/L RATIO DEGRADATION FP 7 BLEND3 0.72 22-10-04 10:10:52 A/L RATIO DEGRADATION FP 7 BLEND3 0.73 22-09-17 10:10:44 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 22-09-06 10:10:24 A/L RATIO DEGRADATION FP 4 BLEND3 0.78 21-09-13 10:10:52 A/L RATIO DEGRADATION FP 1 BLEND3 0.77 19-09-06 10:11:01 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 19-09-03 10:11:23 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-19 10:11:15 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-18 10:29:43 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 10:29:43 ISD STARTUP 23-07-18 10:29:38 ISD SHUTDOWN 23-07-14 10:10:52 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-13 17:48:34 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-13 17:48:34 ISD STARTUP 23-07-13 17:29:00 ISD SHUTDOWN 23-04-30 10:10:09 READINESS ISD:PP EVR:PP ISD & EVR READY 23-04-30 02:51:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING ALARM HISTORY (AFTER) I10200 JUL 24, 2023 5:53 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39334 39097 2 4 PROBE / G.T. 163624 162885 3 INTERSTITIAL BD 202241 201440 4 INTERSTITIAL BD 201618 200907 5 UNUSED 10065686 9852824 6 UNUSED 10026804 9839763 7 UNUSED 10019950 9836314 8 UNUSED 10013054 9828838 9 RELAY BOARD 14936 14925 10 RELAY BOARD 14957 14925 11 UNUSED 10031584 9839539 12 UNUSED 10015933 9833998 13 UNUSED 10001969 9833576 14 UNUSED 10004553 9832241 15 UNUSED 10003934 9832819 16 UNUSED 9996247 9833242 COMM 1 ELEC DISP INT. 101008 100901 COMM 2 RS232 SERIAL BD 15000 14970 COMM 3 RS232 SERIAL BD 14936 14903 COMM 4 UNUSED 10014994 9851665 COMM 5 UNUSED 10008845 9833264 COMM 6 UNUSED 10002439 9827123 I90200 JUL 24, 2023 5:53 PM SOFTWARE REVISION LEVEL VERSION 334.00 SOFTWARE# 346334-100-A CREATED - 15.05.29.10.36 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 24, 2023 5:53 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 3 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-24-23 1:46PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-24-23 1:46PM L 8 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L 7 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L15 ANNULAR UNL 1ANN SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L14 PIPE S. TRANS SUMP SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L13 PIPE N. TRANS SUMP SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L10 OTHER DISP 3-4 SENSOR OUT ALARM CLEAR 7-24-23 1:45PM L 8 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 3 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 7 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 5 STP SUMP PNL STP SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-24-23 1:44PM L15 ANNULAR UNL 1ANN SENSOR OUT ALARM ALARM 7-24-23 1:44PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-24-23 1:44PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-24-23 1:44PM L14 PIPE S. TRANS SUMP SENSOR OUT ALARM ALARM 7-24-23 1:44PM L10 OTHER DISP 3-4 SENSOR OUT ALARM ALARM 7-24-23 1:44PM L13 PIPE N. TRANS SUMP SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-24-23 1:44PM L 8 ANNULAR DSL ANN FUEL ALARM CLEAR 7-24-23 1:41PM L 8 ANNULAR DSL ANN FUEL ALARM ALARM 7-24-23 1:41PM L15 ANNULAR UNL 1ANN FUEL ALARM CLEAR 7-24-23 1:40PM L15 ANNULAR UNL 1ANN FUEL ALARM ALARM 7-24-23 1:40PM L 4 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 7-24-23 1:31PM L 4 ANNULAR UNL 2 ANN FUEL ALARM ALARM 7-24-23 1:31PM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 7-24-23 1:30PM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 7-24-23 1:30PM L 7 STP SUMP DSL STP FUEL ALARM CLEAR 7-24-23 1:28PM L 7 STP SUMP DSL STP FUEL ALARM ALARM 7-24-23 1:28PM L 5 STP SUMP PNL STP FUEL ALARM CLEAR 7-24-23 1:27PM L 5 STP SUMP PNL STP FUEL ALARM ALARM 7-24-23 1:27PM L 3 STP SUMP UNL 2 STP FUEL ALARM CLEAR 7-24-23 1:26PM L 3 STP SUMP UNL 2 STP FUEL ALARM ALARM 7-24-23 1:26PM L 3 STP SUMP UNL 2 STP FUEL ALARM CLEAR 7-24-23 1:25PM L 3 STP SUMP UNL 2 STP FUEL ALARM ALARM 7-24-23 1:25PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-24-23 1:24PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-24-23 1:24PM L10 OTHER DISP 3-4 FUEL ALARM CLEAR 7-24-23 1:23PM L10 OTHER DISP 3-4 FUEL ALARM ALARM 7-24-23 1:22PM L14 PIPE S. TRANS SUMP FUEL ALARM CLEAR 7-24-23 1:22PM L14 PIPE S. TRANS SUMP FUEL ALARM ALARM 7-24-23 1:22PM I11200 JUL 24, 2023 5:53 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 7-24-23 1:56PM SYSTEM PAPER OUT CLEAR 7-24-23 1:56PM SYSTEM PAPER OUT ALARM 7-24-23 1:56PM SYSTEM PAPER OUT CLEAR 7-24-23 1:56PM SYSTEM PRINTER ERROR ALARM 7-24-23 1:54PM SYSTEM PAPER OUT ALARM 7-24-23 1:53PM SYSTEM PRINTER ERROR CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT ALARM 7-22-23 12:41AM SYSTEM PAPER OUT CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT ALARM 7-22-23 12:41AM SYSTEM PAPER OUT CLEAR 7-22-23 12:41AM SYSTEM PAPER OUT ALARM 7-22-23 12:41AM SYSTEM PRINTER ERROR ALARM 7-22-23 12:41AM L 2 ANNULAR UNL 1 ANN SETUP DATA WARNING CLEAR 7-18-23 10:28AM L 2 ANNULAR UNL 1 ANN SETUP DATA WARNING ALARM 7-18-23 10:27AM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:47PM SYSTEM PAPER OUT CLEAR 7-05-23 3:47PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:47PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:47PM SYSTEM PAPER OUT ALARM 7-05-23 3:46PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:46PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:46PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:46PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:45PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:45PM SYSTEM PAPER OUT CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR CLEAR 7-05-23 3:45PM SYSTEM PAPER OUT ALARM 7-05-23 3:45PM SYSTEM PAPER OUT CLEAR 7-05-23 3:45PM SYSTEM PRINTER ERROR ALARM 7-05-23 3:45PM SYSTEM PAPER OUT ALARM 7-05-23 3:44PM SYSTEM PRINTER ERROR CLEAR 6-24-23 8:55AM SYSTEM PAPER OUT CLEAR 6-24-23 8:55AM SYSTEM PRINTER ERROR ALARM 6-24-23 8:55AM SYSTEM PRINTER ERROR CLEAR 6-24-23 8:55AM SYSTEM PAPER OUT ALARM 6-24-23 8:55AM SYSTEM PRINTER ERROR ALARM 6-24-23 8:55AM SYSTEM PRINTER ERROR CLEAR 6-22-23 9:24AM SYSTEM PAPER OUT CLEAR 6-22-23 9:24AM SYSTEM PAPER OUT ALARM 6-22-23 9:24AM SYSTEM PRINTER ERROR ALARM 6-22-23 9:24AM SYSTEM PRINTER ERROR CLEAR 6-20-23 2:54PM SYSTEM PRINTER ERROR ALARM 6-20-23 2:54PM SYSTEM PRINTER ERROR CLEAR 6-20-23 2:54PM SYSTEM PAPER OUT CLEAR 6-20-23 2:54PM SYSTEM PAPER OUT ALARM 6-20-23 2:54PM SYSTEM PAPER OUT CLEAR 6-20-23 2:54PM I20600 JUL 24, 2023 5:53 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 TANK ALARM HISTORY TANK 1 UNLEADED 1 HIGH WATER ALARM JUN 3, 2016 1:07 PM OVERFILL ALARM JUL 3, 2023 9:46 PM JUL 3, 2023 10:35 AM MAY 4, 2023 2:16 AM HIGH PRODUCT ALARM JUL 23, 2020 1:13 PM JUL 5, 2018 2:13 PM JUN 27, 2018 9:36 AM INVALID FUEL LEVEL APR 29, 2023 5:18 PM APR 18, 2021 11:32 AM MAY 5, 2020 12:55 PM PROBE OUT JUL 5, 2018 2:14 PM JUL 5, 2018 2:08 PM JUN 27, 2018 9:37 AM HIGH WATER WARNING JUN 3, 2016 1:07 PM DELIVERY NEEDED APR 29, 2023 4:02 PM APR 19, 2021 9:21 AM APR 18, 2021 10:10 AM MAX PRODUCT ALARM JUL 23, 2020 1:13 PM JUL 5, 2017 11:05 AM LOW TEMP WARNING JUN 27, 2018 9:37 AM JUN 27, 2016 2:06 PM TANK 2 UNLEADED 2 HIGH WATER ALARM JUL 6, 2016 3:55 PM JUL 6, 2016 3:42 PM JUL 6, 2016 3:30 PM OVERFILL ALARM JUL 20, 2023 2:06 AM JUN 29, 2023 7:55 AM JUN 22, 2023 2:36 AM HIGH PRODUCT ALARM JUL 23, 2020 1:14 PM JAN 17, 2020 7:51 AM JUL 5, 2018 2:12 PM INVALID FUEL LEVEL JUL 5, 2017 10:32 AM JUL 6, 2016 2:45 PM JUN 27, 2016 3:36 PM PROBE OUT JUL 5, 2018 2:12 PM JUL 5, 2018 2:07 PM JUN 27, 2018 9:40 AM HIGH WATER WARNING JUL 6, 2016 3:55 PM JUL 6, 2016 3:42 PM JUL 6, 2016 3:30 PM DELIVERY NEEDED APR 23, 2020 12:20 PM JUL 5, 2017 10:32 AM JUL 6, 2016 2:45 PM MAX PRODUCT ALARM JUL 23, 2020 1:14 PM JUL 5, 2017 11:03 AM JUL 6, 2016 3:31 PM LOW TEMP WARNING JUL 5, 2018 2:13 PM JUN 27, 2018 9:41 AM JUL 18, 2016 5:14 PM TANK 3 PREMIUM HIGH WATER ALARM OCT 27, 2016 11:23 AM OVERFILL ALARM JUN 30, 2022 6:11 AM MAY 15, 2018 10:54 AM JUN 28, 2017 10:56 AM HIGH PRODUCT ALARM JUL 23, 2020 1:15 PM JUL 5, 2018 2:11 PM JUN 27, 2018 9:31 AM INVALID FUEL LEVEL AUG 20, 2018 1:42 PM AUG 18, 2018 10:34 AM JUN 27, 2018 9:32 AM PROBE OUT JUL 5, 2018 2:11 PM JUL 5, 2018 2:06 PM JUN 27, 2018 9:32 AM HIGH WATER WARNING OCT 27, 2016 11:23 AM DELIVERY NEEDED DEC 19, 2022 10:48 PM MAR 21, 2019 1:52 PM AUG 19, 2018 9:03 AM MAX PRODUCT ALARM JUL 23, 2020 1:15 PM LOW TEMP WARNING OCT 27, 2016 11:43 AM OCT 27, 2016 11:35 AM JUL 18, 2016 5:39 PM TANK 4 DIESEL OVERFILL ALARM JUL 5, 2017 11:00 AM JUN 28, 2017 10:57 AM HIGH PRODUCT ALARM JUL 23, 2020 1:15 PM JUL 5, 2018 2:09 PM JUN 27, 2018 9:30 AM INVALID FUEL LEVEL NOV 30, 2022 5:03 PM NOV 29, 2022 2:57 PM JAN 24, 2022 8:07 AM PROBE OUT JUN 28, 2021 9:54 AM JUL 5, 2018 2:10 PM JUL 5, 2018 2:05 PM DELIVERY NEEDED JUN 17, 2023 3:53 PM MAR 27, 2023 3:32 PM NOV 30, 2022 2:22 PM MAX PRODUCT ALARM JUL 23, 2020 1:15 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 24, 2023 5:54 PM I30200 JUL 24, 2023 5:54 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:24 PM FUEL ALARM JUL 18, 2023 10:35 AM FUEL ALARM 3 UNL 2 STP JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:26 PM FUEL ALARM JUL 24, 2023 1:25 PM FUEL ALARM 4 UNL 2 ANN JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:31 PM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM 5 PNL STP JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:27 PM FUEL ALARM JUL 18, 2023 10:36 AM FUEL ALARM 6 PNL ANN JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:30 PM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM 7 DSL STP JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:28 PM FUEL ALARM JUL 18, 2023 10:36 AM FUEL ALARM 8 DSL ANN JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:41 PM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM 9 DISP 1-2 JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:21 PM FUEL ALARM JUL 18, 2023 10:39 AM FUEL ALARM 10 DISP 3-4 JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:22 PM FUEL ALARM JUL 18, 2023 10:37 AM FUEL ALARM 11 DISP 5-6 JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:19 PM FUEL ALARM JUL 24, 2023 1:19 PM FUEL ALARM 12 DISP 7-8 JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:17 PM FUEL ALARM JUL 18, 2023 10:41 AM FUEL ALARM 13 N. TRANS SUMP JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:18 PM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM 14 S. TRANS SUMP JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:22 PM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM 15 UNL 1ANN JUL 24, 2023 1:44 PM SENSOR OUT ALARM JUL 24, 2023 1:40 PM FUEL ALARM JUL 18, 2023 10:30 AM SENSOR OUT ALARM I31600 JUL 24, 2023 5:54 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 DEC 13, 2021 6:46 PM COMMUNICATION ALARM APR 23, 2017 12:48 PM COMMUNICATION ALARM APR 8, 2016 4:33 PM COMMUNICATION ALARM 2 FM 1-2 APR 14, 2022 5:09 PM COMMUNICATION ALARM APR 14, 2022 3:29 PM COMMUNICATION ALARM APR 13, 2022 7:32 PM COMMUNICATION ALARM 3 FM 3-4 APR 8, 2016 4:33 PM COMMUNICATION ALARM 4 FM 5-6 APR 8, 2016 4:33 PM COMMUNICATION ALARM 5 FM 7-8 APR 8, 2016 4:34 PM COMMUNICATION ALARM I40200 JUL 24, 2023 5:54 PM I40300 JUL 24, 2023 5:54 PM I34200 JUL 24, 2023 5:54 PM I34700 JUL 24, 2023 5:54 PM IV0100 JUL 24, 2023 5:54 PM FASTRIP 775 4901 S UNION BAKERSFIELD CA93307 661-391-9387 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-04-16 10:10:20 A/L RATIO DEGRADATION FP 6 BLEND3 BLKD 23-04-16 10:10:20 A/L RATIO DEGRADATION FP 5 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO DEGRADATION FP 6 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO DEGRADATION FP 5 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-04-14 10:10:09 A/L RATIO DEGRADATION FP 6 BLEND3 BLKD 23-04-14 10:10:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 22-11-30 10:10:44 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.00 22-11-29 10:10:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.00 22-11-28 10:10:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.00 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-04-16 10:10:20 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 23-04-16 10:10:20 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-04-15 10:10:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 22-10-05 10:10:50 A/L RATIO DEGRADATION FP 7 BLEND3 0.72 22-10-04 10:10:52 A/L RATIO DEGRADATION FP 7 BLEND3 0.73 22-09-17 10:10:44 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 22-09-06 10:10:24 A/L RATIO DEGRADATION FP 4 BLEND3 0.78 21-09-13 10:10:52 A/L RATIO DEGRADATION FP 1 BLEND3 0.77 19-09-06 10:11:01 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 19-09-03 10:11:23 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-07-24 14:17:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-24 14:17:51 ISD STARTUP 23-07-24 14:17:46 ISD SHUTDOWN 23-07-19 10:11:15 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-18 10:29:43 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-18 10:29:43 ISD STARTUP 23-07-18 10:29:38 ISD SHUTDOWN 23-07-14 10:10:52 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-13 17:48:34 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-07-13 17:48:34 ISD STARTUP