Loading...
HomeMy WebLinkAboutFMC 2023Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10155971 8/22/2023 Jaco #7773 Fastrip #31 3501 Mt. Vernon Ave. Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 Veeder Root ATG B47853 7/30/2024 OPW 8/21/2024 8/22/2023 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 420 Unl ann L2 420 DSL ann L3 Not used L4 208 Unl STP L5 208 DSL STP L6 208 Pnl STP L7 420 Pnl ann L8 Not used L9 208 Disp 1-2 L10 208 Disp 3-4 L11 208 Disp 5-6 L12 208 Disp 7-8 L13 208 Trans sump Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 T2 FX1V 91 T3 FX1DV DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. PARKIN G 175'EXISTING BUILDINGNO PRICE SIGNMOUNT VERNON AVE.UNIVERSITY AVE.CATCHBASIN N 94.2'50'117.5'180'HSTPL4 AL1 V F L11 G W PROPERTY LINE PROPERTY LINEL12 L9L10 DUMPS T ER L13 12,000 GALLONDIESEL 12,000 GALLONPREMIUM40' STORAGE C ONTAINE R 40' STORAGE C ONTAINE R STPL5 AL2 V F STPL6 AL3 V F 12,000 GALLON87 UNL LEGEND L1 87 ANNULAR L2 DSL ANNULAR L3 91 ANNULAR L4 87 STP L5 DSL STP L6 91 STP L9 UDC 1 - 2 L10 UDC 3 - 4 L11 UDC 5 - 6 L12 UDC 7 - 8 L13 TRANS SUMP 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SITE MAP SITE PLAN C1 TAB:SITE PLAN 1"=10'-0" INCHES012 SHEET SIZE 22 X 34 DATE REVISIONS DATE: DRAWN BY: CHECKED: APPROVED: RAC FASTRIP - 7-773 CADFILE: SHEET NO.7773-MSP A.P.N.:382-020-16-00-8 SCALE: FASTRIP FOOD STORECONVENIENCE MARKET FOR: BAKERSFIELD, CALIFORNIA 93306 JAMIESON HILL 3501 MT VERNON AVE. 3101 STATE RDBAKERSFIELD, CA 93308 PROJECT OWNER: DRAWING: CD 10/13/2020 3501 MT VERNON AVE.BAKERSFIELD, CA 93306 MT VERNON AVE.UNIVERSITY AVE. PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID 15-021-003018 CERS ID 10155971 FASTRIP #7773 3501 MT VERNON AVE. BAKERSFIELD, CA 93306 10/13/2020 REV. VICINITY MAP PROJECT DATA APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #7773 Fastrip #313501 Mt. Vernon Ave.Bakersfield101559713-47-8MPDMPD MPD MPD 1-25-6ProductProductProductProductAaron Perrigo Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10155971 8/22/2023 Jaco #7773 Fastrip #31 3501 Mt. Vernon Ave.Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Aaron Perrigo 1073967 8485827 8/8/2024 OPW 0148613 8/21/2024 PEI 1200 lake test All fill spill buckets 8/22/2023 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. 87 OPW 91 OPW DSL OPW Jaco 7773 Setup Responses Received: 200 FASTRIP 773 3501 MT VERNON BAKERSFIELD CA AUG 22, 2023 9:20 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 4045 40.98 0.0 82.9 8017 2 DIESEL 9587 82.28 1.0 89.4 2475 3 PREMIUM 8858 76.44 0.0 91.3 3204 I90500 AUG 22, 2023 9:20 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 AUG 22, 2023 9:20 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 22, 2023 9:20 AM SHIFT TIME 1 : DISABLED I50202 AUG 22, 2023 9:20 AM SHIFT TIME 2 : DISABLED I50203 AUG 22, 2023 9:20 AM SHIFT TIME 3 : DISABLED I50204 AUG 22, 2023 9:20 AM SHIFT TIME 4 : DISABLED I54600 AUG 22, 2023 9:20 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 22, 2023 9:20 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 22, 2023 9:20 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 22, 2023 9:20 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 22, 2023 9:20 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 22, 2023 9:20 AM PRINT TC VOLUMES ENABLED I50E00 AUG 22, 2023 9:20 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 22, 2023 9:20 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 22, 2023 9:20 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 22, 2023 9:20 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 22, 2023 9:20 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 AUG 22, 2023 9:20 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 22, 2023 9:20 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 22, 2023 9:20 AM TANK CHART SECURITY DISABLED I5BD00 AUG 22, 2023 9:20 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 22, 2023 9:20 AM MASS/DENSITY DISABLED I88101 AUG 22, 2023 9:20 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 AUG 22, 2023 9:20 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 22, 2023 9:20 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 AUG 22, 2023 9:20 AM I88105 AUG 22, 2023 9:20 AM I88106 AUG 22, 2023 9:20 AM I52000 AUG 22, 2023 9:20 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE OCT 12, 2017 DISABLED 2 ON DATE OCT 12, 2017 DISABLED 3 ON DATE OCT 12, 2017 DISABLED 4 ON DATE OCT 12, 2017 DISABLED 5 ON DATE OCT 12, 2017 DISABLED 6 ON DATE OCT 12, 2017 DISABLED 7 ON DATE OCT 12, 2017 DISABLED 8 ON DATE OCT 12, 2017 DISABLED I60100 AUG 22, 2023 9:20 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 DIESEL ON 3 PREMIUM ON 4 OFF I60200 AUG 22, 2023 9:20 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 DIESEL 3 PREMIUM 4 I60300 AUG 22, 2023 9:21 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 DIESEL 2 3 PREMIUM 3 4 4 I60900 AUG 22, 2023 9:21 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 DIESEL 0.000450 3 PREMIUM 0.000700 4 0.000000 I60700 AUG 22, 2023 9:21 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.00 2 DIESEL 111.00 3 PREMIUM 111.00 4 0.00 I60A00 AUG 22, 2023 9:21 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12062 2 DIESEL 1 PT 12062 3 PREMIUM 1 PT 12062 4 1 PT 0 I60400 AUG 22, 2023 9:21 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 DIESEL 12062 3 PREMIUM 12062 4 0 I60500 AUG 22, 2023 9:21 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 2 DIESEL 12062 0 0 0 3 PREMIUM 12062 0 0 0 4 0 0 0 0 I60600 AUG 22, 2023 9:21 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 22, 2023 9:21 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 DIESEL NO 3 PREMIUM NO 4 NO I62F00 AUG 22, 2023 9:21 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 DIESEL 4.0 IN. 3 PREMIUM 4.0 IN. I62700 AUG 22, 2023 9:21 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 DIESEL 2.0 3 PREMIUM 2.0 I64200 AUG 22, 2023 9:21 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 DIESEL LOW 3 PREMIUM LOW I62400 AUG 22, 2023 9:21 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 DIESEL 3.0 3 PREMIUM 3.0 I62800 AUG 22, 2023 9:21 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 DIESEL 12062 3 PREMIUM 12062 4 0 I62300 AUG 22, 2023 9:21 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10856 2 DIESEL 10856 3 PREMIUM 10856 4 0 I62200 AUG 22, 2023 9:21 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11459 2 DIESEL 11459 3 PREMIUM 11459 4 0 I62900 AUG 22, 2023 9:21 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1809 2 DIESEL 1809 3 PREMIUM 1809 4 0 I62100 AUG 22, 2023 9:21 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 DIESEL 500 3 PREMIUM 500 4 0 I62600 AUG 22, 2023 9:21 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 DIESEL 99 3 PREMIUM 99 4 99 I62500 AUG 22, 2023 9:21 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 DIESEL 99 3 PREMIUM 99 4 99 I60800 AUG 22, 2023 9:21 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 DIESEL 0.00 3 PREMIUM 0.00 4 0.00 I60B00 AUG 22, 2023 9:21 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 22, 2023 9:21 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 DIESEL 0.00 3 PREMIUM 0.00 4 0.00 I61200 AUG 22, 2023 9:21 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 DIESEL NONE NONE 3 PREMIUM NONE NONE 4 NONE NONE I63600 AUG 22, 2023 9:21 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 DIESEL 120 3 PREMIUM 120 4 0 I62A00 AUG 22, 2023 9:21 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 DIESEL 120 3 PREMIUM 120 4 0 I62C00 AUG 22, 2023 9:21 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 DIESEL STANDARD 3 PREMIUM STANDARD 4 STANDARD I62D00 AUG 22, 2023 9:21 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 22, 2023 9:21 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 DIESEL OFF OFF 3 PREMIUM OFF OFF 4 OFF OFF I63000 AUG 22, 2023 9:21 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 DIESEL OFF 3 PREMIUM OFF 4 OFF I63200 AUG 22, 2023 9:21 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 DIESEL OFF 3 PREMIUM OFF 4 OFF I61000 AUG 22, 2023 9:21 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 DIESEL 1 3 PREMIUM 1 4 1 I63A00 AUG 22, 2023 9:21 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 DIESEL 10.00% 3 PREMIUM 10.00% 4 10.00% I61100 AUG 22, 2023 9:21 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK MAR 22, 2011 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 22, 2023 9:21 AM CSLD PROBABLITY OF DETECTION I61400 AUG 22, 2023 9:21 AM CSLD CLIMATE FACTOR I61600 AUG 22, 2023 9:21 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 DIESEL IMMEDIATE 3 PREMIUM IMMEDIATE 4 IMMEDIATE I61A00 AUG 22, 2023 9:21 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 DIESEL DISABLED 3 PREMIUM DISABLED 4 DISABLED I61B00 AUG 22, 2023 9:21 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 22, 2023 9:21 AM CSLD REPORT ONLY I62B00 AUG 22, 2023 9:21 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 DIESEL ??? 0, 0 3 PREMIUM ??? 0, 0 4 ??? 0, 0 I63300 AUG 22, 2023 9:21 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 22, 2023 9:21 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 DIESEL 0 3 PREMIUM 0 4 0 I63500 AUG 22, 2023 9:21 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 DIESEL 1 3 PREMIUM 1 4 1 I63900 AUG 22, 2023 9:21 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 END FACTOR: NONE I78000 AUG 22, 2023 9:21 AM I77700 AUG 22, 2023 9:21 AM I77800 AUG 22, 2023 9:21 AM I78C00 AUG 22, 2023 9:21 AM I78300 AUG 22, 2023 9:21 AM I78F00 AUG 22, 2023 9:21 AM I78700 AUG 22, 2023 9:21 AM I70200 AUG 22, 2023 9:21 AM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 DSL ANN 3 PNL ANM 4 UNL STP 5 DSL STP 6 PNL STP 7 PNL ANN 8 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUNP 14 15 16 I70300 AUG 22, 2023 9:21 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 DSL ANN TRI-STATE (SINGLE FLOAT) 3 PNL ANM TRI-STATE (SINGLE FLOAT) 4 UNL STP TRI-STATE (SINGLE FLOAT) 5 DSL STP TRI-STATE (SINGLE FLOAT) 6 PNL STP TRI-STATE (SINGLE FLOAT) 7 PNL ANN TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUNP TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 AUG 22, 2023 9:21 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 DSL ANN ANNULAR SPACE 3 PNL ANM ANNULAR SPACE 4 UNL STP STP SUMP 5 DSL STP STP SUMP 6 PNL STP STP SUMP 7 PNL ANN ANNULAR SPACE 8 OTHER SENSORS 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUNP PIPING SUMP 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 AUG 22, 2023 9:21 AM I74300 AUG 22, 2023 9:21 AM I74400 AUG 22, 2023 9:21 AM I74700 AUG 22, 2023 9:21 AM I74800 AUG 22, 2023 9:21 AM I74900 AUG 22, 2023 9:21 AM I7BC00 AUG 22, 2023 9:21 AM I80200 AUG 22, 2023 9:21 AM I80300 AUG 22, 2023 9:21 AM I80400 AUG 22, 2023 9:21 AM I80700 AUG 22, 2023 9:21 AM RELAY LABEL DEVICE LABEL 1 UNL 2 PNL 3 DSL 4 OVERFILL ALARM I80900 AUG 22, 2023 9:21 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 AUG 22, 2023 9:21 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 2 PNL 3 3 DSL 2 4 OVERFILL ALARM NONE I80A00 AUG 22, 2023 9:21 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 OVERFILL ALARM STANDARD I80C00 AUG 22, 2023 9:21 AM I80800 AUG 22, 2023 9:21 AM RELAY SETUP REPORT R 1:UNL TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 4:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 4:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 6:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 5:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 5:SENSOR OUT ALARM L10:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 5:SHORT ALARM L10:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 AUG 22, 2023 9:22 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 22, 2023 9:22 AM I72300 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 1-2 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 1-2 AIR FLOW METER 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA VAPOR PROCESSOR TYPE NONE IV4700 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ACCEPT HIGH ORVR: YES IV4A00 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 22, 2023 9:22 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 22, 2023 9:22 AM ISD VERSION: 01.07 Jaco 7773 Alarm History Responses Received: I10200 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508304 507576 2 INTERSTITIAL BD 202003 201875 3 4 PROBE / G.T. 161879 161697 4 INTERSTITIAL BD 201406 201100 5 UNUSED 9470693 9586529 6 UNUSED 9460594 9576556 7 UNUSED 9461650 9585523 8 UNUSED 9454301 9574391 9 STP SENSE BOARD 33193 33162 10 RELAY BOARD 15036 15072 11 UNUSED 9466281 9583505 12 UNUSED 9456335 9582696 13 UNUSED 9456049 9577994 14 UNUSED 9458492 9575391 15 UNUSED 9456225 9577075 16 UNUSED 9461198 9571520 COMM 1 ELEC DISP INT. 101303 101179 COMM 2 RS232 SERIAL BD 14926 14941 COMM 3 RS232 SERIAL BD 14970 14985 COMM 4 UNUSED 9460648 9578956 COMM 5 UNUSED 9455037 9576988 COMM 6 UNUSED 9460406 9573292 I90200 AUG 22, 2023 9:23 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME E 1 OTHER COMMUNICATION ALARM CLEAR 8-15-23 3:53PM E 1 OTHER COMMUNICATION ALARM ALARM 8-15-23 3:52PM T 3 TANK PREMIUM OVERFILL ALARM CLEAR 8-12-23 12:04AM T 3 TANK PREMIUM OVERFILL ALARM ALARM 8-12-23 12:02AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-07-23 1:09PM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-07-23 12:36PM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-07-23 12:36PM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-07-23 12:35PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-07-23 12:34PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-07-23 12:33PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-07-23 12:32PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-07-23 12:30PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-07-23 12:30PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-07-23 12:28PM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-07-23 10:15AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-07-23 10:14AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-07-23 10:14AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L13 PIPE TRANS SUNP SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-07-23 10:13AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 4 STP SUMP UNL STP SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 6 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-07-23 10:13AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-07-23 10:13AM L13 PIPE TRANS SUNP SENSOR OUT ALARM ALARM 8-07-23 10:13AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-07-23 10:13AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-07-23 10:13AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 8-07-23 10:09AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 8-07-23 10:09AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-07-23 10:08AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-07-23 10:08AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 8-07-23 10:07AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 8-07-23 10:07AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-07-23 10:06AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-07-23 10:06AM L13 PIPE TRANS SUNP FUEL ALARM CLEAR 8-07-23 10:03AM L13 PIPE TRANS SUNP FUEL ALARM ALARM 8-07-23 10:03AM L 4 STP SUMP UNL STP FUEL ALARM CLEAR 8-07-23 10:02AM L 4 STP SUMP UNL STP FUEL ALARM ALARM 8-07-23 10:02AM I11200 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 8-20-23 10:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 8-19-23 10:02AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 8-18-23 9:40AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 8-18-23 7:20AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 8-16-23 6:03PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 8-16-23 4:55PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:45PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:44PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:44PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:44PM SYSTEM PAPER OUT CLEAR 8-09-23 3:44PM SYSTEM PAPER OUT ALARM 8-09-23 3:44PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:44PM SYSTEM PAPER OUT CLEAR 8-09-23 3:43PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:43PM SYSTEM PAPER OUT ALARM 8-09-23 3:43PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:42PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:42PM SYSTEM PAPER OUT CLEAR 8-09-23 3:42PM SYSTEM PAPER OUT ALARM 8-09-23 3:42PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:42PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:42PM SYSTEM PAPER OUT CLEAR 8-09-23 3:42PM SYSTEM PAPER OUT ALARM 8-09-23 5:53AM OTHER ISD SENSOR OUT WARN CLEAR 8-03-23 10:36AM SYSTEM PRINTER ERROR CLEAR 8-01-23 6:21PM SYSTEM PRINTER ERROR ALARM 8-01-23 6:21PM SYSTEM PAPER OUT CLEAR 8-01-23 6:20PM SYSTEM PAPER OUT ALARM 8-01-23 6:20PM SYSTEM PAPER OUT CLEAR 8-01-23 6:20PM SYSTEM PAPER OUT ALARM 8-01-23 6:19PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-31-23 11:06AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-31-23 9:42AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-29-23 10:43PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-29-23 7:29PM OTHER ISD SENSOR OUT WARN ALARM 7-29-23 10:01AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-28-23 10:22PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-28-23 7:17PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-21-23 12:49PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-21-23 12:37PM SYSTEM PRINTER ERROR CLEAR 7-20-23 11:44AM SYSTEM PRINTER ERROR ALARM 7-20-23 11:44AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 7-19-23 10:00AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-15-23 2:28AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-14-23 11:15PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-14-23 1:18PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 7-14-23 1:14PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 7-14-23 12:16PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-14-23 10:21AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-13-23 4:48AM I20600 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM AUG 7, 2023 4:36 AM JUL 30, 2023 9:53 AM JUL 19, 2023 12:08 PM LOW PRODUCT ALARM JUL 14, 2023 12:12 PM JUL 12, 2023 11:02 PM JUL 7, 2023 5:55 PM INVALID FUEL LEVEL JUL 14, 2023 12:16 PM JUL 12, 2023 11:28 PM JUL 7, 2023 5:58 PM DELIVERY NEEDED AUG 18, 2023 7:20 AM AUG 16, 2023 4:55 PM JUL 31, 2023 9:42 AM TANK 2 DIESEL DELIVERY NEEDED JAN 12, 2023 4:57 PM JAN 8, 2023 4:23 PM DEC 20, 2022 8:24 AM TANK 3 PREMIUM HIGH WATER ALARM MAR 11, 2023 6:45 PM MAR 10, 2023 3:24 PM OVERFILL ALARM AUG 12, 2023 12:02 AM JUL 25, 2023 11:57 PM JUN 28, 2023 10:53 AM SUDDEN LOSS ALARM MAR 12, 2023 3:10 PM PROBE OUT MAR 12, 2023 6:03 PM MAR 12, 2023 2:45 PM MAR 12, 2023 2:42 PM HIGH WATER WARNING MAR 11, 2023 6:45 PM MAR 10, 2023 3:24 PM LOW TEMP WARNING MAR 12, 2023 2:12 PM MAR 12, 2023 2:07 PM MAR 12, 2023 1:59 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 22, 2023 9:23 AM I30200 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN AUG 7, 2023 12:36 PM FUEL ALARM AUG 7, 2023 12:35 PM FUEL ALARM AUG 7, 2023 12:33 PM SENSOR OUT ALARM 2 DSL ANN AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 9:57 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 4 UNL STP AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 10:02 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 5 DSL STP AUG 7, 2023 10:14 AM SENSOR OUT ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 9:59 AM FUEL ALARM 6 PNL STP AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 9:58 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 7 PNL ANN AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 9:58 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 9 DISP 1-2 AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 10:09 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 10 DISP 3-4 AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 10:07 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 11 DISP 5-6 AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 10:08 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 12 DISP 7-8 AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 10:06 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM 13 TRANS SUNP AUG 7, 2023 10:13 AM SENSOR OUT ALARM AUG 7, 2023 10:03 AM FUEL ALARM AUG 11, 2022 9:41 AM SENSOR OUT ALARM I31600 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 AUG 3, 2023 11:35 AM COMMUNICATION ALARM JUL 29, 2023 8:10 AM COMMUNICATION ALARM 3 FM 3-4 4 FM 5-6 JUL 6, 2023 12:26 PM COMMUNICATION ALARM 5 FM 7-8 I40200 AUG 22, 2023 9:23 AM I40300 AUG 22, 2023 9:23 AM I34200 AUG 22, 2023 9:23 AM I34700 AUG 22, 2023 9:23 AM IV0100 AUG 22, 2023 9:23 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-08-19 10:02:02 A/L RATIO DEGRADATION FP 6 BLEND3 0.78 23-08-03 10:01:40 SENSOR OUT SELFTEST s 2 23-08-02 10:02:07 SENSOR OUT SELFTEST s 2 23-08-01 10:02:15 SENSOR OUT SELFTEST s 2 23-07-31 10:02:16 SENSOR OUT SELFTEST s 2 23-07-30 10:01:54 SENSOR OUT SELFTEST s 2 23-07-29 10:01:54 SENSOR OUT SELFTEST s 2 23-07-18 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.74 23-07-17 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.75 23-07-16 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.76 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-07-19 10:01:14 A/L RATIO DEGRADATION FP 5 BLEND3 0.75 23-03-06 10:02:29 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 21-04-14 10:02:04 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 19-03-20 10:01:25 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-08-22 07:54:58 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-08-22 07:54:58 ISD STARTUP 23-08-22 07:54:09 ISD SHUTDOWN 23-08-08 10:01:40 READINESS ISD:PP EVR:PP ISD & EVR READY 23-08-07 10:15:24 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-08-07 10:15:24 ISD STARTUP 23-08-07 10:15:13 ISD SHUTDOWN 23-08-03 10:36:50 SENSOR OUT TEST MANUALLY CLEARED 23-07-26 10:01:34 READINESS ISD:PP EVR:PP ISD & EVR READY 23-07-25 15:34:54 READINESS ISD:PP EVR:NN EVR READINESS PENDING Jaco 7773 Alarm History After Responses Received: I10200 AUG 22, 2023 10:59 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508304 507599 2 INTERSTITIAL BD 202003 201729 3 4 PROBE / G.T. 161879 161647 4 INTERSTITIAL BD 201406 201019 5 UNUSED 9470693 9527517 6 UNUSED 9460594 9523325 7 UNUSED 9461650 9517859 8 UNUSED 9454301 9521744 9 STP SENSE BOARD 33193 33162 10 RELAY BOARD 15036 15073 11 UNUSED 9466281 9526651 12 UNUSED 9456335 9517959 13 UNUSED 9456049 9519781 14 UNUSED 9458492 9512209 15 UNUSED 9456225 9515347 16 UNUSED 9461198 9519935 COMM 1 ELEC DISP INT. 101303 101211 COMM 2 RS232 SERIAL BD 14926 14941 COMM 3 RS232 SERIAL BD 14970 15007 COMM 4 UNUSED 9460648 9531173 COMM 5 UNUSED 9455037 9520308 COMM 6 UNUSED 9460406 9517411 I90200 AUG 22, 2023 10:59 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 22, 2023 10:59 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 7 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L13 PIPE TRANS SUNP SENSOR OUT ALARM CLEAR 8-22-23 10:27AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-22-23 10:26AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-22-23 10:26AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-22-23 10:26AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-22-23 10:26AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-22-23 10:26AM L13 PIPE TRANS SUNP SENSOR OUT ALARM ALARM 8-22-23 10:26AM L 4 STP SUMP UNL STP SENSOR OUT ALARM ALARM 8-22-23 10:26AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-22-23 10:26AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-22-23 10:26AM L 7 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-22-23 10:25AM L 6 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-22-23 10:25AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-22-23 10:25AM L 7 ANNULAR PNL ANN FUEL ALARM CLEAR 8-22-23 10:13AM L 7 ANNULAR PNL ANN FUEL ALARM ALARM 8-22-23 10:13AM L 2 ANNULAR DSL ANN FUEL ALARM CLEAR 8-22-23 10:12AM L 2 ANNULAR DSL ANN FUEL ALARM ALARM 8-22-23 10:11AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-22-23 10:08AM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-22-23 10:07AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-22-23 10:07AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-22-23 10:06AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-22-23 10:05AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-22-23 10:04AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 8-22-23 10:03AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 8-22-23 10:02AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 8-22-23 10:02AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 8-22-23 10:01AM L13 PIPE TRANS SUNP FUEL ALARM CLEAR 8-22-23 10:00AM L13 PIPE TRANS SUNP FUEL ALARM ALARM 8-22-23 9:59AM L 4 STP SUMP UNL STP FUEL ALARM CLEAR 8-22-23 9:57AM L 4 STP SUMP UNL STP FUEL ALARM ALARM 8-22-23 9:57AM L 5 STP SUMP DSL STP FUEL ALARM CLEAR 8-22-23 9:57AM L 5 STP SUMP DSL STP FUEL ALARM ALARM 8-22-23 9:57AM L 6 STP SUMP PNL STP FUEL ALARM CLEAR 8-22-23 9:56AM L 6 STP SUMP PNL STP FUEL ALARM ALARM 8-22-23 9:56AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-15-23 3:53PM E 1 OTHER COMMUNICATION ALARM ALARM 8-15-23 3:52PM T 3 TANK PREMIUM OVERFILL ALARM CLEAR 8-12-23 12:04AM T 3 TANK PREMIUM OVERFILL ALARM ALARM 8-12-23 12:02AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-07-23 1:09PM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-07-23 12:36PM I11200 AUG 22, 2023 10:59 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 8-20-23 10:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 8-19-23 10:02AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 8-18-23 9:40AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 8-18-23 7:20AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 8-16-23 6:03PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 8-16-23 4:55PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:45PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:44PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:44PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:44PM SYSTEM PAPER OUT CLEAR 8-09-23 3:44PM SYSTEM PAPER OUT ALARM 8-09-23 3:44PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:44PM SYSTEM PAPER OUT CLEAR 8-09-23 3:43PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:43PM SYSTEM PAPER OUT ALARM 8-09-23 3:43PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:42PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:42PM SYSTEM PAPER OUT CLEAR 8-09-23 3:42PM SYSTEM PAPER OUT ALARM 8-09-23 3:42PM SYSTEM PRINTER ERROR CLEAR 8-09-23 3:42PM SYSTEM PRINTER ERROR ALARM 8-09-23 3:42PM SYSTEM PAPER OUT CLEAR 8-09-23 3:42PM SYSTEM PAPER OUT ALARM 8-09-23 5:53AM OTHER ISD SENSOR OUT WARN CLEAR 8-03-23 10:36AM SYSTEM PRINTER ERROR CLEAR 8-01-23 6:21PM SYSTEM PRINTER ERROR ALARM 8-01-23 6:21PM SYSTEM PAPER OUT CLEAR 8-01-23 6:20PM SYSTEM PAPER OUT ALARM 8-01-23 6:20PM SYSTEM PAPER OUT CLEAR 8-01-23 6:20PM SYSTEM PAPER OUT ALARM 8-01-23 6:19PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-31-23 11:06AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-31-23 9:42AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-29-23 10:43PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-29-23 7:29PM OTHER ISD SENSOR OUT WARN ALARM 7-29-23 10:01AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-28-23 10:22PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-28-23 7:17PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-21-23 12:49PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-21-23 12:37PM SYSTEM PRINTER ERROR CLEAR 7-20-23 11:44AM SYSTEM PRINTER ERROR ALARM 7-20-23 11:44AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 7-19-23 10:00AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-15-23 2:28AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-14-23 11:15PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-14-23 1:18PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 7-14-23 1:14PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 7-14-23 12:16PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-14-23 10:21AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-13-23 4:48AM I20600 AUG 22, 2023 10:59 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM AUG 7, 2023 4:36 AM JUL 30, 2023 9:53 AM JUL 19, 2023 12:08 PM LOW PRODUCT ALARM JUL 14, 2023 12:12 PM JUL 12, 2023 11:02 PM JUL 7, 2023 5:55 PM INVALID FUEL LEVEL JUL 14, 2023 12:16 PM JUL 12, 2023 11:28 PM JUL 7, 2023 5:58 PM DELIVERY NEEDED AUG 18, 2023 7:20 AM AUG 16, 2023 4:55 PM JUL 31, 2023 9:42 AM TANK 2 DIESEL DELIVERY NEEDED JAN 12, 2023 4:57 PM JAN 8, 2023 4:23 PM DEC 20, 2022 8:24 AM TANK 3 PREMIUM HIGH WATER ALARM MAR 11, 2023 6:45 PM MAR 10, 2023 3:24 PM OVERFILL ALARM AUG 12, 2023 12:02 AM JUL 25, 2023 11:57 PM JUN 28, 2023 10:53 AM SUDDEN LOSS ALARM MAR 12, 2023 3:10 PM PROBE OUT MAR 12, 2023 6:03 PM MAR 12, 2023 2:45 PM MAR 12, 2023 2:42 PM HIGH WATER WARNING MAR 11, 2023 6:45 PM MAR 10, 2023 3:24 PM LOW TEMP WARNING MAR 12, 2023 2:12 PM MAR 12, 2023 2:07 PM MAR 12, 2023 1:59 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 AUG 22, 2023 11:00 AM I30200 AUG 22, 2023 11:00 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 10:07 AM FUEL ALARM AUG 7, 2023 12:36 PM FUEL ALARM 2 DSL ANN AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 10:11 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 4 UNL STP AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 9:57 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 5 DSL STP AUG 22, 2023 10:25 AM SENSOR OUT ALARM AUG 22, 2023 9:57 AM FUEL ALARM AUG 7, 2023 10:14 AM SENSOR OUT ALARM 6 PNL STP AUG 22, 2023 10:25 AM SENSOR OUT ALARM AUG 22, 2023 9:56 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 7 PNL ANN AUG 22, 2023 10:25 AM SENSOR OUT ALARM AUG 22, 2023 10:13 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 9 DISP 1-2 AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 10:01 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 10 DISP 3-4 AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 10:02 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 11 DISP 5-6 AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 10:06 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 12 DISP 7-8 AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 10:04 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM 13 TRANS SUNP AUG 22, 2023 10:26 AM SENSOR OUT ALARM AUG 22, 2023 9:59 AM FUEL ALARM AUG 7, 2023 10:13 AM SENSOR OUT ALARM I31600 AUG 22, 2023 11:00 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 AUG 3, 2023 11:35 AM COMMUNICATION ALARM JUL 29, 2023 8:10 AM COMMUNICATION ALARM 3 FM 3-4 4 FM 5-6 JUL 6, 2023 12:26 PM COMMUNICATION ALARM 5 FM 7-8 I40200 AUG 22, 2023 11:00 AM I40300 AUG 22, 2023 11:00 AM I34200 AUG 22, 2023 11:00 AM I34700 AUG 22, 2023 11:00 AM IV0100 AUG 22, 2023 11:00 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-08-19 10:02:02 A/L RATIO DEGRADATION FP 6 BLEND3 0.78 23-08-03 10:01:40 SENSOR OUT SELFTEST s 2 23-08-02 10:02:07 SENSOR OUT SELFTEST s 2 23-08-01 10:02:15 SENSOR OUT SELFTEST s 2 23-07-31 10:02:16 SENSOR OUT SELFTEST s 2 23-07-30 10:01:54 SENSOR OUT SELFTEST s 2 23-07-29 10:01:54 SENSOR OUT SELFTEST s 2 23-07-18 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.74 23-07-17 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.75 23-07-16 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.76 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-07-19 10:01:14 A/L RATIO DEGRADATION FP 5 BLEND3 0.75 23-03-06 10:02:29 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-07-08 10:01:30 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 21-04-14 10:02:04 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-10-19 10:02:47 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 19-03-20 10:01:25 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 19-02-07 10:02:18 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-08-22 10:24:41 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-08-22 10:24:41 ISD STARTUP 23-08-22 10:23:36 ISD SHUTDOWN 23-08-22 10:01:55 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-08-22 07:54:58 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-08-22 07:54:58 ISD STARTUP 23-08-22 07:54:09 ISD SHUTDOWN 23-08-08 10:01:40 READINESS ISD:PP EVR:PP ISD & EVR READY 23-08-07 10:15:24 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-08-07 10:15:24 ISD STARTUP