Loading...
HomeMy WebLinkAboutFMC 2023 REJECTEDAppendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10120951 06/19/2023 Mesa Marin Chevron 11101 Highway 178 Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 VeederRoot TLS-3XX Technician - C32655 10/11/2024 Vaporless Manufacturing Inc.10/21/2024 OPW - 1193585 04/14/2025 06/19/2023 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208/304 Dispenser 1-2 L2 208/304 Dispenser 3-4 L3 208/304 Dispenser 5-6 L4 208/304 Dispenser 7-8 L5 208/304 Dispenser 9-10 L6 208/304 Dispenser 11-12 L7 208/304 87 Unleaded STP L8 208/304 87 Unleaded Fill L9 208/304 91 Premium STP L10 208/304 91 Premium Fill L11 208/304 Diesel STP L12 208/304 Diesel Fill L13 208/304 Vent Box Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 Unleaded T2 FX1V 91 Premium T3 FX1DV Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ All liquid sensors are linked together via VeederRoot 2 to 1 Sensor Input Box 857390-102. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 06/19/2023 APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Mesa Marin Chevron11101 Highway 178Bakersfield101209513-47-8 11-12MPDMPDMPDMPDMPDMPD1-25-69-10ProductProductProductProductProductProductBrandon Nunez Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10120951 06/19/2023 Mesa Marin Chevron 11101 Highway 178 Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 OPW - 1193585 04/14/2025 PEI 1200 1 Hour Hydrostatic All Spill Buckets 06/19/2023 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1: 87 UNL OPW T2: 91 PNL OPW T3: Diesel OPW Mesa Chevron System Setup Responses Received: 200 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 JUN 19, 2023 12:59 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 8641 64.63 0.0 84.7 3391 2 SUPREME 3895 34.44 0.0 81.7 8137 3 DIESEL 4193 36.27 0.0 82.6 7882 I90500 JUN 19, 2023 12:59 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUN 19, 2023 12:59 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUN 19, 2023 12:59 PM SHIFT TIME 1 : 1:00 AM I50202 JUN 19, 2023 12:59 PM SHIFT TIME 2 : DISABLED I50203 JUN 19, 2023 12:59 PM SHIFT TIME 3 : DISABLED I50204 JUN 19, 2023 12:59 PM SHIFT TIME 4 : DISABLED I54600 JUN 19, 2023 12:59 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUN 19, 2023 12:59 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUN 19, 2023 12:59 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUN 19, 2023 12:59 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUN 19, 2023 12:59 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUN 19, 2023 12:59 PM PRINT TC VOLUMES ENABLED I50E00 JUN 19, 2023 12:59 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUN 19, 2023 12:59 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUN 19, 2023 12:59 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUN 19, 2023 12:59 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUN 19, 2023 12:59 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUN 19, 2023 12:59 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUN 19, 2023 12:59 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUN 19, 2023 12:59 PM TANK CHART SECURITY DISABLED I5BD00 JUN 19, 2023 12:59 PM CUSTOM ALARM LABELS DISABLED I56000 JUN 19, 2023 12:59 PM MASS/DENSITY DISABLED I88101 JUN 19, 2023 12:59 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUN 19, 2023 12:59 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUN 19, 2023 12:59 PM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 JUN 19, 2023 12:59 PM I88105 JUN 19, 2023 12:59 PM I88106 JUN 19, 2023 12:59 PM I52000 JUN 19, 2023 12:59 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 WEEKLY SUN 4:52 PM 2 WEEKLY SUN 4:52 PM 3 WEEKLY SUN 4:52 PM 4 WEEKLY SUN 4:52 PM 5 WEEKLY SUN 4:52 PM 6 WEEKLY SUN 4:52 PM 7 WEEKLY SUN 4:52 PM 8 VEEDER ROOT (FMS) WEEKLY FRI 4:51 PM I60100 JUN 19, 2023 12:59 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 SUPREME ON 3 DIESEL ON 4 OFF I60200 JUN 19, 2023 12:59 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 SUPREME 3 DIESEL 4 I60300 JUN 19, 2023 12:59 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 SUPREME 2 3 DIESEL 3 4 4 I60900 JUN 19, 2023 12:59 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 SUPREME 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 JUN 19, 2023 12:59 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 95.75 2 SUPREME 95.75 3 DIESEL 95.75 4 0.00 I60A00 JUN 19, 2023 12:59 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12032 2 SUPREME 1 PT 12032 3 DIESEL 1 PT 12075 4 1 PT 0 I60400 JUN 19, 2023 12:59 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 SUPREME 12032 3 DIESEL 12075 4 0 I60500 JUN 19, 2023 12:59 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 2 SUPREME 12032 0 0 0 3 DIESEL 12075 0 0 0 4 0 0 0 0 I60600 JUN 19, 2023 12:59 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 SUPREME 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12075 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUN 19, 2023 12:59 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 SUPREME NO 3 DIESEL NO 4 NO I62F00 JUN 19, 2023 12:59 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. PS 2 SUPREME 4.0 IN. PS 3 DIESEL 4.0 IN. I62700 JUN 19, 2023 12:59 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 SUPREME 2.0 3 DIESEL 2.0 I64200 JUN 19, 2023 12:59 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 SUPREME LOW 3 DIESEL LOW I62400 JUN 19, 2023 12:59 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 SUPREME 3.0 3 DIESEL 3.0 I62800 JUN 19, 2023 12:59 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 SUPREME 12032 3 DIESEL 12075 4 0 I62300 JUN 19, 2023 12:59 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10829 2 SUPREME 10829 3 DIESEL 10868 4 0 I62200 JUN 19, 2023 12:59 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11430 2 SUPREME 11430 3 DIESEL 11471 4 0 I62900 JUN 19, 2023 12:59 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 SUPREME 120 3 DIESEL 121 4 0 I62100 JUN 19, 2023 12:59 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 SUPREME 500 3 DIESEL 500 4 0 I62600 JUN 19, 2023 12:59 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 SUPREME 99 3 DIESEL 99 4 99 I62500 JUN 19, 2023 12:59 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 SUPREME 99 3 DIESEL 99 4 99 I60800 JUN 19, 2023 12:59 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 SUPREME 0.00 3 DIESEL 0.00 4 0.00 I60B00 JUN 19, 2023 12:59 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUN 19, 2023 12:59 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 SUPREME 0.00 3 DIESEL 0.00 4 0.00 I61200 JUN 19, 2023 12:59 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 SUPREME NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 JUN 19, 2023 12:59 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 SUPREME 120 3 DIESEL 120 4 0 I62A00 JUN 19, 2023 12:59 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 SUPREME 120 3 DIESEL 120 4 0 I62C00 JUN 19, 2023 12:59 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 SUPREME STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 JUN 19, 2023 12:59 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPREME GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUN 19, 2023 12:59 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 SUPREME OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 JUN 19, 2023 12:59 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 SUPREME OFF 3 DIESEL OFF 4 OFF I63200 JUN 19, 2023 12:59 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 SUPREME OFF 3 DIESEL OFF 4 OFF I61000 JUN 19, 2023 12:59 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 SUPREME 1 3 DIESEL 1 4 1 I63A00 JUN 19, 2023 12:59 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 SUPREME 10.00% 3 DIESEL 10.00% 4 10.00% I61100 JUN 19, 2023 12:59 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 2, 2019 START TIME : 2:00 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:ENABLED I61300 JUN 19, 2023 12:59 PM CSLD PROBABLITY OF DETECTION I61400 JUN 19, 2023 12:59 PM CSLD CLIMATE FACTOR I61600 JUN 19, 2023 12:59 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 SUPREME IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 JUN 19, 2023 12:59 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED ENABLED 2 SUPREME ENABLED 3 DIESEL ENABLED 4 ENABLED I61B00 JUN 19, 2023 12:59 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUN 19, 2023 12:59 PM CSLD REPORT ONLY I62B00 JUN 19, 2023 12:59 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 SUPREME ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 JUN 19, 2023 1:00 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUN 19, 2023 1:00 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 SUPREME 0 3 DIESEL 0 4 0 I63500 JUN 19, 2023 1:00 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 SUPREME 1 3 DIESEL 1 4 1 I63900 JUN 19, 2023 1:00 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 SUPREME END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 JUN 19, 2023 1:00 PM I77700 JUN 19, 2023 1:00 PM I77800 JUN 19, 2023 1:00 PM I78C00 JUN 19, 2023 1:00 PM I78300 JUN 19, 2023 1:00 PM I78F00 JUN 19, 2023 1:00 PM I78700 JUN 19, 2023 1:00 PM I70200 JUN 19, 2023 1:00 PM LIQUID LABEL DEVICE LABEL 1 DISP 1-2 2 DISP 3-4 3 DISP 5-6 4 DISP 7-8 5 DISP 9-10 6 DISP 11-12 7 UNL STP 8 UNL FILL 9 SUPREME STP 10 SUPREME FILL 11 DIESEL STP 12 DIESEL FILL 13 VENT BOX 14 15 16 I70300 JUN 19, 2023 1:00 PM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1-2 DW SUMP 2-1 2 DISP 3-4 DW SUMP 2-1 3 DISP 5-6 DW SUMP 2-1 4 DISP 7-8 DW SUMP 2-1 5 DISP 9-10 DW SUMP 2-1 6 DISP 11-12 DW SUMP 2-1 7 UNL STP DW SUMP 2-1 8 UNL FILL DW SUMP 2-1 9 SUPREME STP DW SUMP 2-1 10 SUPREME FILL DW SUMP 2-1 11 DIESEL STP DW SUMP 2-1 12 DIESEL FILL DW SUMP 2-1 13 VENT BOX DW SUMP 2-1 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUN 19, 2023 1:00 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1-2 DISPENSER PAN 2 DISP 3-4 DISPENSER PAN 3 DISP 5-6 DISPENSER PAN 4 DISP 7-8 DISPENSER PAN 5 DISP 9-10 DISPENSER PAN 6 DISP 11-12 DISPENSER PAN 7 UNL STP STP SUMP 8 UNL FILL OTHER SENSORS 9 SUPREME STP STP SUMP 10 SUPREME FILL OTHER SENSORS 11 DIESEL STP STP SUMP 12 DIESEL FILL OTHER SENSORS 13 VENT BOX OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUN 19, 2023 1:00 PM I74300 JUN 19, 2023 1:00 PM I74400 JUN 19, 2023 1:00 PM I74700 JUN 19, 2023 1:00 PM I74800 JUN 19, 2023 1:00 PM I74900 JUN 19, 2023 1:00 PM I7BC00 JUN 19, 2023 1:00 PM I80200 JUN 19, 2023 1:00 PM I80300 JUN 19, 2023 1:00 PM I80400 JUN 19, 2023 1:00 PM I80700 JUN 19, 2023 1:00 PM RELAY LABEL DEVICE LABEL 1 UNL 2 SUPREME 3 DIESEL 4 OVERFILL ALARM I80900 JUN 19, 2023 1:00 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL NORMALLY OPEN 2 SUPREME NORMALLY OPEN 3 DIESEL NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUN 19, 2023 1:00 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 2 SUPREME 2 3 DIESEL 3 4 OVERFILL ALARM NONE I80A00 JUN 19, 2023 1:00 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL PUMP CONTROL OUTPUT 2 SUPREME PUMP CONTROL OUTPUT 3 DIESEL PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD I80C00 JUN 19, 2023 1:00 PM I80800 JUN 19, 2023 1:00 PM RELAY SETUP REPORT R 1:UNL TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:SUPREME TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 2:FUEL ALARM L 6:FUEL ALARM L11:FUEL ALARM L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 2:SHORT ALARM L 6:SHORT ALARM L11:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUN 19, 2023 1:01 PM EDIM:1 VR:349867-001-D TD:17.02.14.08.38 I79100 JUN 19, 2023 1:01 PM I72300 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DISP 1-2 FM AIR FLOW METER 02 DISP 3-4 FM AIR FLOW METER 03 DISP 5-6 FM AIR FLOW METER 04 DISP 7-8 FM AIR FLOW METER 05 DISP 9-10 FM AIR FLOW METER 06 DISP 11-12 FM AIR FLOW METER 07 DISP 5-6 PS VAPOR PRESSURE 08 ATM ATM P SENSOR 09 UNL TANK VAC SENSOR 10 UNL PRODUCT VAC SENSOR 11 VAPOR RETURN VAC SENSOR 12 SUPREME TANK VAC SENSOR 13 SUPREME PRODUCT VAC SENSOR 14 UNL-SUP VENT VAC SENSOR 15 DIESEL TANK VAC SENSOR 16 DIESEL PRODUCT VAC SENSOR 17 DIESEL VENT VAC SENSOR 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 EVR/ISD SETUP TYPE: BALANCE IV4F00 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 VAPOR PROCESSOR TYPE NONE IV4700 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ACCEPT HIGH ORVR: NO IV4A00 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx 05 03 02/05 09/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 09/07 01/07 02/07 xx/xx 08 04 02/08 09/08 01/08 xx/xx 09 05 02/09 01/09 09/09 xx/xx 16 05 02/10 09/10 01/10 xx/xx 17 06 02/11 09/11 01/11 xx/xx 18 06 02/12 09/12 01/12 xx/xx IV4900 JUN 19, 2023 1:01 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUN 19, 2023 1:01 PM ISD VERSION: 01.06 Mesa Chevron Pre Alarm History Responses Received: I10200 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164210 164472 2 7SMARTSENSOR BD 505619 507027 3 8SMARTSENSOR BD 39372 39365 4 8SMARTSENSOR BD 39394 39476 5 INTERSTITIAL BD 201554 201955 6 INTERSTITIAL BD 201229 201461 7 UNUSED 4936496 4877361 8 UNUSED 4934375 4877166 9 RELAY BOARD 14978 14978 10 STP SENSE BOARD 33087 33132 11 UNUSED 4945617 4875156 12 UNUSED 4942939 4871907 13 UNUSED 4936532 4870218 14 UNUSED 4936382 4876564 15 UNUSED 4932718 4875936 16 UNUSED 4941032 4870174 COMM 1 ELEC DISP INT. 101260 101332 COMM 2 RS232 SERIAL BD 14914 14912 COMM 3 SERIAL SAT BD 480641 481644 COMM 4 UNUSED 4942232 4875546 COMM 5 UNUSED 4941139 4872687 COMM 6 UNUSED 4935461 4869395 I90200 JUN 19, 2023 1:02 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 8:58AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 8:58AM L10 OTHER SUPREME FILL FUEL ALARM CLEAR 6-19-23 8:35AM L10 OTHER SUPREME FILL FUEL ALARM ALARM 6-19-23 8:33AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 2:35AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 2:35AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-19-23 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 6-19-23 2:10AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-16-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-16-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-16-23 11:06AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-16-23 11:06AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-14-23 11:05AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-14-23 11:05AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-14-23 10:40AM E 1 OTHER COMMUNICATION ALARM ALARM 6-14-23 10:40AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-09-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-09-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-07-23 6:37AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-07-23 6:37AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-05-23 6:35AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-05-23 6:35AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-05-23 6:11AM E 1 OTHER COMMUNICATION ALARM ALARM 6-05-23 6:10AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-02-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-02-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-31-23 2:28AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-31-23 2:28AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-29-23 2:27AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-29-23 2:27AM E 1 OTHER COMMUNICATION ALARM CLEAR 5-29-23 2:02AM E 1 OTHER COMMUNICATION ALARM ALARM 5-29-23 2:02AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-28-23 3:41PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-28-23 3:41PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-26-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-26-23 5:16PM L 8 OTHER UNL FILL FUEL ALARM CLEAR 5-26-23 3:15PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-24-23 2:26AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-24-23 2:26AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-22-23 2:25AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-22-23 2:25AM E 1 OTHER COMMUNICATION ALARM CLEAR 5-22-23 2:01AM E 1 OTHER COMMUNICATION ALARM ALARM 5-22-23 2:00AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-20-23 9:32AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-20-23 9:32AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-19-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-19-23 5:16PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-18-23 11:45AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-18-23 11:45AM s14 OTHER UNL-SUP VENT NO VACUUM ALARM CLEAR 5-18-23 11:39AM I11200 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 6-19-23 10:56AM SYSTEM PAPER OUT CLEAR 6-19-23 10:56AM SYSTEM PAPER OUT ALARM 6-19-23 10:55AM SYSTEM PRINTER ERROR ALARM 6-19-23 10:55AM SYSTEM PRINTER ERROR CLEAR 6-15-23 12:14AM SYSTEM PRINTER ERROR ALARM 6-15-23 12:13AM SYSTEM PAPER OUT CLEAR 6-15-23 12:13AM SYSTEM PAPER OUT ALARM 6-15-23 12:13AM SYSTEM PRINTER ERROR CLEAR 5-25-23 5:17AM SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM SYSTEM PAPER OUT ALARM 5-25-23 5:17AM SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM SYSTEM PRINTER ERROR ALARM 5-25-23 5:17AM SYSTEM PAPER OUT ALARM 5-25-23 5:17AM SYSTEM PRINTER ERROR CLEAR 5-09-23 11:39PM SYSTEM PAPER OUT CLEAR 5-09-23 11:39PM SYSTEM PRINTER ERROR ALARM 5-09-23 11:38PM SYSTEM PAPER OUT ALARM 5-09-23 11:38PM SYSTEM PRINTER ERROR CLEAR 5-08-23 6:23AM SYSTEM PRINTER ERROR ALARM 5-08-23 6:23AM SYSTEM PRINTER ERROR CLEAR 4-16-23 11:41PM SYSTEM PAPER OUT CLEAR 4-16-23 11:41PM SYSTEM PRINTER ERROR ALARM 4-16-23 11:40PM SYSTEM PAPER OUT ALARM 4-16-23 11:40PM SYSTEM PRINTER ERROR CLEAR 2-15-23 7:58PM SYSTEM PAPER OUT CLEAR 2-15-23 7:58PM SYSTEM PAPER OUT ALARM 2-15-23 7:57PM SYSTEM PRINTER ERROR ALARM 2-15-23 7:57PM SYSTEM PRINTER ERROR CLEAR 2-12-23 3:16AM SYSTEM PRINTER ERROR ALARM 2-12-23 3:16AM SYSTEM PAPER OUT CLEAR 2-12-23 3:16AM SYSTEM PAPER OUT ALARM 2-11-23 10:51PM L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 12:03PM L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 12:03PM L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 10:22AM L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 10:22AM SYSTEM PRINTER ERROR CLEAR 1-20-23 11:41PM SYSTEM PAPER OUT CLEAR 1-20-23 11:41PM SYSTEM PRINTER ERROR ALARM 1-20-23 11:41PM SYSTEM PAPER OUT ALARM 1-20-23 11:41PM OTHER ISD VAPOR LEAK WARN CLEAR 12-07-22 10:03AM OTHER ISD VAPOR LEAK WARN ALARM 12-06-22 10:03AM SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM SYSTEM PAPER OUT CLEAR 11-15-22 7:13AM SYSTEM PRINTER ERROR ALARM 11-15-22 7:13AM SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM SYSTEM PAPER OUT ALARM 11-15-22 7:12AM SYSTEM PRINTER ERROR ALARM 11-15-22 7:12AM SYSTEM PRINTER ERROR CLEAR 10-24-22 7:20AM SYSTEM PAPER OUT CLEAR 10-24-22 7:20AM I20600 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 SUPREME TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUN 19, 2023 1:02 PM I30200 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:17 AM FUEL ALARM OCT 11, 2022 9:17 AM LOW LIQUID ALARM 2 DISP 3-4 OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:17 AM FUEL ALARM OCT 11, 2022 9:16 AM LOW LIQUID ALARM 3 DISP 5-6 OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:18 AM FUEL ALARM OCT 11, 2022 9:18 AM LOW LIQUID ALARM 4 DISP 7-8 OCT 11, 2022 9:45 AM LOW LIQUID ALARM OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:18 AM FUEL ALARM 5 DISP 9-10 OCT 25, 2022 9:34 PM LOW LIQUID ALARM OCT 23, 2022 11:02 PM LOW LIQUID ALARM OCT 11, 2022 9:42 AM SENSOR OUT ALARM 6 DISP 11-12 OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:19 AM FUEL ALARM OCT 11, 2022 9:19 AM LOW LIQUID ALARM 7 UNL STP OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:35 AM FUEL ALARM OCT 11, 2022 9:35 AM LOW LIQUID ALARM 8 UNL FILL APR 19, 2023 10:03 AM FUEL ALARM FEB 7, 2023 12:34 PM LOW LIQUID ALARM FEB 7, 2023 12:24 PM SENSOR OUT ALARM 9 SUPREME STP OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:34 AM FUEL ALARM OCT 11, 2022 9:33 AM LOW LIQUID ALARM 10 SUPREME FILL JUN 19, 2023 8:33 AM FUEL ALARM FEB 26, 2023 11:33 AM FUEL ALARM FEB 10, 2023 3:13 PM SENSOR OUT ALARM 11 DIESEL STP OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:31 AM FUEL ALARM OCT 11, 2022 9:31 AM LOW LIQUID ALARM 12 DIESEL FILL APR 1, 2023 6:39 PM FUEL ALARM OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:25 AM LOW LIQUID ALARM 13 VENT BOX NOV 2, 2022 12:44 AM LOW LIQUID ALARM OCT 11, 2022 9:42 AM SENSOR OUT ALARM OCT 11, 2022 9:24 AM FUEL ALARM I31600 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 FM 2 DISP 3-4 FM 3 DISP 5-6 FM 4 DISP 7-8 FM 5 DISP 9-10 FM 6 DISP 11-12 FM 7 DISP 5-6 PS 8 ATM 9 UNL TANK 10 UNL PRODUCT OCT 11, 2022 9:36 AM HIGH LIQUID ALARM OCT 11, 2022 9:36 AM NO VACUUM ALARM 11 VAPOR RETURN MAY 18, 2023 11:22 AM NO VACUUM ALARM OCT 11, 2022 9:36 AM HIGH LIQUID ALARM OCT 11, 2022 9:36 AM NO VACUUM ALARM 12 SUPREME TANK MAY 18, 2023 11:32 AM NO VACUUM ALARM 13 SUPREME PRODUCT DEC 7, 2022 3:10 PM HIGH LIQUID ALARM OCT 11, 2022 9:34 AM HIGH LIQUID ALARM OCT 11, 2022 9:34 AM NO VACUUM ALARM 14 UNL-SUP VENT MAY 18, 2023 9:42 AM NO VACUUM ALARM MAY 18, 2023 9:41 AM NO VACUUM ALARM MAY 18, 2023 9:40 AM NO VACUUM ALARM 15 DIESEL TANK 16 DIESEL PRODUCT OCT 11, 2022 9:32 AM NO VACUUM ALARM OCT 11, 2022 9:32 AM HIGH LIQUID ALARM 17 DIESEL VENT OCT 11, 2022 9:32 AM NO VACUUM ALARM OCT 11, 2022 9:32 AM HIGH LIQUID ALARM I40200 JUN 19, 2023 1:02 PM I40300 JUN 19, 2023 1:02 PM I34200 JUN 19, 2023 1:02 PM I34700 JUN 19, 2023 1:02 PM IV0100 JUN 19, 2023 1:02 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :NOTEST EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-12-06 10:03:20 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.06 22-10-06 10:03:52 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 38.55 22-10-05 10:03:48 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 37.45 22-10-04 10:03:56 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 33.33 22-10-03 10:03:55 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 32.76 22-10-02 10:03:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.98 22-10-01 10:03:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.95 22-09-30 10:03:11 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 30.32 22-09-24 10:04:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.92 22-09-23 10:03:58 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.91 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-10-09 10:03:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 43.37 22-10-08 10:03:42 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.44 22-10-07 10:03:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.38 22-06-11 10:07:00 FLOW PERFORMANCE HOSE BLOCKAGE FP 7 BLEND3 22-03-05 10:07:15 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 21-09-07 10:07:55 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-08-18 10:08:51 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-07-26 10:05:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 5 BLEND3 21-04-12 10:05:16 FLOW PERFORMANCE HOSE BLOCKAGE FP 9 BLEND3 20-03-11 10:05:46 FLOW PERFORMANCE HOSE BLOCKAGE FP11 BLEND3 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-06-19 11:10:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-06-19 11:10:57 ISD STARTUP 23-06-19 11:07:31 ISD SHUTDOWN 23-06-19 10:07:56 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-18 10:08:10 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-17 10:07:41 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-16 10:08:04 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-15 10:08:27 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-14 10:08:35 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-13 10:08:12 READINESS ISD:PP EVR:NP EVR READINESS PENDING Mesa Chevron Post Alarm History Responses Received: I10200 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164210 164472 2 7SMARTSENSOR BD 505619 507027 3 8SMARTSENSOR BD 39372 39365 4 8SMARTSENSOR BD 39394 39476 5 INTERSTITIAL BD 201554 201955 6 INTERSTITIAL BD 201229 201461 7 UNUSED 4936496 4877361 8 UNUSED 4934375 4877166 9 RELAY BOARD 14978 14978 10 STP SENSE BOARD 33087 33132 11 UNUSED 4945617 4875156 12 UNUSED 4942939 4871907 13 UNUSED 4936532 4870218 14 UNUSED 4936382 4876564 15 UNUSED 4932718 4875936 16 UNUSED 4941032 4870174 COMM 1 ELEC DISP INT. 101260 101332 COMM 2 RS232 SERIAL BD 14914 14912 COMM 3 SERIAL SAT BD 480641 481644 COMM 4 UNUSED 4942232 4875546 COMM 5 UNUSED 4941139 4872687 COMM 6 UNUSED 4935461 4869395 I90200 JUN 19, 2023 3:37 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME s16 OTHER DIESEL PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:34PM s17 OTHER DIESEL VENT HIGH LIQUID ALARM CLEAR 6-19-23 3:34PM s16 OTHER DIESEL PRODUCT NO VACUUM ALARM CLEAR 6-19-23 3:34PM s17 OTHER DIESEL VENT NO VACUUM ALARM CLEAR 6-19-23 3:34PM s16 OTHER DIESEL PRODUCT NO VACUUM ALARM ALARM 6-19-23 3:33PM s17 OTHER DIESEL VENT NO VACUUM ALARM ALARM 6-19-23 3:33PM s17 OTHER DIESEL VENT HIGH LIQUID ALARM ALARM 6-19-23 3:31PM s16 OTHER DIESEL PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:31PM s14 OTHER UNL-SUP VENT HIGH LIQUID ALARM CLEAR 6-19-23 3:27PM s13 OTHER SUPREME PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:27PM s14 OTHER UNL-SUP VENT NO VACUUM ALARM CLEAR 6-19-23 3:27PM s13 OTHER SUPREME PRODUCT NO VACUUM ALARM CLEAR 6-19-23 3:27PM s14 OTHER UNL-SUP VENT NO VACUUM ALARM ALARM 6-19-23 3:26PM s13 OTHER SUPREME PRODUCT NO VACUUM ALARM ALARM 6-19-23 3:25PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 3:24PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 3:24PM s14 OTHER UNL-SUP VENT HIGH LIQUID ALARM ALARM 6-19-23 3:23PM s13 OTHER SUPREME PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:23PM s11 OTHER VAPOR RETURN HIGH LIQUID ALARM CLEAR 6-19-23 3:22PM s10 OTHER UNL PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:22PM s11 OTHER VAPOR RETURN HIGH LIQUID ALARM ALARM 6-19-23 3:22PM s10 OTHER UNL PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:22PM s11 OTHER VAPOR RETURN HIGH LIQUID ALARM CLEAR 6-19-23 3:17PM s10 OTHER UNL PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:17PM s11 OTHER VAPOR RETURN NO VACUUM ALARM CLEAR 6-19-23 3:16PM s11 OTHER VAPOR RETURN NO VACUUM ALARM ALARM 6-19-23 3:16PM s10 OTHER UNL PRODUCT NO VACUUM ALARM CLEAR 6-19-23 3:16PM s10 OTHER UNL PRODUCT NO VACUUM ALARM ALARM 6-19-23 3:13PM s11 OTHER VAPOR RETURN HIGH LIQUID ALARM ALARM 6-19-23 3:11PM s10 OTHER UNL PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:11PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 1:48PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 1:48PM L12 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L10 OTHER SUPREME FILL SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L11 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 9 STP SUMP SUPREME STP SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L13 OTHER VENT BOX SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 8 OTHER UNL FILL SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 7 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 6 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 2 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 3 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM L 8 OTHER UNL FILL SENSOR OUT ALARM ALARM 6-19-23 1:42PM L 7 STP SUMP UNL STP SENSOR OUT ALARM ALARM 6-19-23 1:42PM L 6 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 6-19-23 1:42PM L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 6-19-23 1:42PM L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 6-19-23 1:42PM I11200 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 6-19-23 10:56AM SYSTEM PAPER OUT CLEAR 6-19-23 10:56AM SYSTEM PAPER OUT ALARM 6-19-23 10:55AM SYSTEM PRINTER ERROR ALARM 6-19-23 10:55AM SYSTEM PRINTER ERROR CLEAR 6-15-23 12:14AM SYSTEM PRINTER ERROR ALARM 6-15-23 12:13AM SYSTEM PAPER OUT CLEAR 6-15-23 12:13AM SYSTEM PAPER OUT ALARM 6-15-23 12:13AM SYSTEM PRINTER ERROR CLEAR 5-25-23 5:17AM SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM SYSTEM PAPER OUT ALARM 5-25-23 5:17AM SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM SYSTEM PRINTER ERROR ALARM 5-25-23 5:17AM SYSTEM PAPER OUT ALARM 5-25-23 5:17AM SYSTEM PRINTER ERROR CLEAR 5-09-23 11:39PM SYSTEM PAPER OUT CLEAR 5-09-23 11:39PM SYSTEM PRINTER ERROR ALARM 5-09-23 11:38PM SYSTEM PAPER OUT ALARM 5-09-23 11:38PM SYSTEM PRINTER ERROR CLEAR 5-08-23 6:23AM SYSTEM PRINTER ERROR ALARM 5-08-23 6:23AM SYSTEM PRINTER ERROR CLEAR 4-16-23 11:41PM SYSTEM PAPER OUT CLEAR 4-16-23 11:41PM SYSTEM PRINTER ERROR ALARM 4-16-23 11:40PM SYSTEM PAPER OUT ALARM 4-16-23 11:40PM SYSTEM PRINTER ERROR CLEAR 2-15-23 7:58PM SYSTEM PAPER OUT CLEAR 2-15-23 7:58PM SYSTEM PAPER OUT ALARM 2-15-23 7:57PM SYSTEM PRINTER ERROR ALARM 2-15-23 7:57PM SYSTEM PRINTER ERROR CLEAR 2-12-23 3:16AM SYSTEM PRINTER ERROR ALARM 2-12-23 3:16AM SYSTEM PAPER OUT CLEAR 2-12-23 3:16AM SYSTEM PAPER OUT ALARM 2-11-23 10:51PM L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 12:03PM L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 12:03PM L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 10:22AM L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 10:22AM SYSTEM PRINTER ERROR CLEAR 1-20-23 11:41PM SYSTEM PAPER OUT CLEAR 1-20-23 11:41PM SYSTEM PRINTER ERROR ALARM 1-20-23 11:41PM SYSTEM PAPER OUT ALARM 1-20-23 11:41PM OTHER ISD VAPOR LEAK WARN CLEAR 12-07-22 10:03AM OTHER ISD VAPOR LEAK WARN ALARM 12-06-22 10:03AM SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM SYSTEM PAPER OUT CLEAR 11-15-22 7:13AM SYSTEM PRINTER ERROR ALARM 11-15-22 7:13AM SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM SYSTEM PAPER OUT ALARM 11-15-22 7:12AM SYSTEM PRINTER ERROR ALARM 11-15-22 7:12AM SYSTEM PRINTER ERROR CLEAR 10-24-22 7:20AM SYSTEM PAPER OUT CLEAR 10-24-22 7:20AM I20600 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 SUPREME TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUN 19, 2023 3:37 PM I30200 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:31 PM LOW LIQUID ALARM JUN 19, 2023 1:31 PM FUEL ALARM 2 DISP 3-4 JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:34 PM LOW LIQUID ALARM JUN 19, 2023 1:33 PM FUEL ALARM 3 DISP 5-6 JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:29 PM LOW LIQUID ALARM JUN 19, 2023 1:28 PM FUEL ALARM 4 DISP 7-8 JUN 19, 2023 1:42 PM SENSOR OUT ALARM JUN 19, 2023 1:30 PM LOW LIQUID ALARM JUN 19, 2023 1:29 PM FUEL ALARM 5 DISP 9-10 JUN 19, 2023 1:42 PM SENSOR OUT ALARM JUN 19, 2023 1:25 PM LOW LIQUID ALARM JUN 19, 2023 1:25 PM FUEL ALARM 6 DISP 11-12 JUN 19, 2023 1:42 PM SENSOR OUT ALARM JUN 19, 2023 1:27 PM LOW LIQUID ALARM JUN 19, 2023 1:26 PM FUEL ALARM 7 UNL STP JUN 19, 2023 1:42 PM SENSOR OUT ALARM JUN 19, 2023 1:14 PM LOW LIQUID ALARM JUN 19, 2023 1:13 PM FUEL ALARM 8 UNL FILL JUN 19, 2023 1:42 PM SENSOR OUT ALARM JUN 19, 2023 1:22 PM LOW LIQUID ALARM JUN 19, 2023 1:14 PM FUEL ALARM 9 SUPREME STP JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:12 PM LOW LIQUID ALARM JUN 19, 2023 1:12 PM FUEL ALARM 10 SUPREME FILL JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:22 PM LOW LIQUID ALARM JUN 19, 2023 1:15 PM FUEL ALARM 11 DIESEL STP JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:11 PM LOW LIQUID ALARM JUN 19, 2023 1:11 PM FUEL ALARM 12 DIESEL FILL JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:22 PM LOW LIQUID ALARM JUN 19, 2023 1:16 PM FUEL ALARM 13 VENT BOX JUN 19, 2023 1:41 PM SENSOR OUT ALARM JUN 19, 2023 1:17 PM FUEL ALARM NOV 2, 2022 12:44 AM LOW LIQUID ALARM I31600 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 FM 2 DISP 3-4 FM 3 DISP 5-6 FM 4 DISP 7-8 FM 5 DISP 9-10 FM 6 DISP 11-12 FM 7 DISP 5-6 PS 8 ATM 9 UNL TANK 10 UNL PRODUCT JUN 19, 2023 3:22 PM HIGH LIQUID ALARM JUN 19, 2023 3:13 PM NO VACUUM ALARM JUN 19, 2023 3:11 PM HIGH LIQUID ALARM 11 VAPOR RETURN JUN 19, 2023 3:22 PM HIGH LIQUID ALARM JUN 19, 2023 3:16 PM NO VACUUM ALARM JUN 19, 2023 3:11 PM HIGH LIQUID ALARM 12 SUPREME TANK MAY 18, 2023 11:32 AM NO VACUUM ALARM 13 SUPREME PRODUCT JUN 19, 2023 3:25 PM NO VACUUM ALARM JUN 19, 2023 3:23 PM HIGH LIQUID ALARM DEC 7, 2022 3:10 PM HIGH LIQUID ALARM 14 UNL-SUP VENT JUN 19, 2023 3:26 PM NO VACUUM ALARM JUN 19, 2023 3:23 PM HIGH LIQUID ALARM MAY 18, 2023 9:42 AM NO VACUUM ALARM 15 DIESEL TANK 16 DIESEL PRODUCT JUN 19, 2023 3:33 PM NO VACUUM ALARM JUN 19, 2023 3:31 PM HIGH LIQUID ALARM OCT 11, 2022 9:32 AM NO VACUUM ALARM 17 DIESEL VENT JUN 19, 2023 3:33 PM NO VACUUM ALARM JUN 19, 2023 3:31 PM HIGH LIQUID ALARM OCT 11, 2022 9:32 AM NO VACUUM ALARM I40200 JUN 19, 2023 3:37 PM I40300 JUN 19, 2023 3:37 PM I34200 JUN 19, 2023 3:37 PM I34700 JUN 19, 2023 3:37 PM IV0100 JUN 19, 2023 3:37 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :NOTEST EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-12-06 10:03:20 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.06 22-10-06 10:03:52 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 38.55 22-10-05 10:03:48 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 37.45 22-10-04 10:03:56 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 33.33 22-10-03 10:03:55 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 32.76 22-10-02 10:03:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.98 22-10-01 10:03:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.95 22-09-30 10:03:11 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 30.32 22-09-24 10:04:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.92 22-09-23 10:03:58 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.91 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-10-09 10:03:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 43.37 22-10-08 10:03:42 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.44 22-10-07 10:03:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.38 22-06-11 10:07:00 FLOW PERFORMANCE HOSE BLOCKAGE FP 7 BLEND3 22-03-05 10:07:15 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 21-09-07 10:07:55 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-08-18 10:08:51 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-07-26 10:05:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 5 BLEND3 21-04-12 10:05:16 FLOW PERFORMANCE HOSE BLOCKAGE FP 9 BLEND3 20-03-11 10:05:46 FLOW PERFORMANCE HOSE BLOCKAGE FP11 BLEND3 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-06-19 11:10:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-06-19 11:10:57 ISD STARTUP 23-06-19 11:07:31 ISD SHUTDOWN 23-06-19 10:07:56 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-18 10:08:10 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-17 10:07:41 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-16 10:08:04 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-15 10:08:27 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-14 10:08:35 READINESS ISD:PP EVR:NP EVR READINESS PENDING 23-06-13 10:08:12 READINESS ISD:PP EVR:NP EVR READINESS PENDING