HomeMy WebLinkAboutFMC 2023 REJECTEDAppendix VI
Underground Storage Tank
Monitoring System Certification Form
CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification,
ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-
Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank,
VPH = Vacuum/Pressure/Hydrostatic
Page 1 of 6
TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month
1. FACILITY INFORMATION
CERS ID Certification Date
Facility Name
Facility Address City ZIP Code
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Certification Phone
Mailing Address
Service Technician Performing Test
Contractor/Tank Tester License Number
ICC Number ICC Expiration Date
3. TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that the monitoring system is operational in accordance with California Code
of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting
documentation is attached; and all information contained herein is accurate.
Service Technician Signature Date Total # of Pages
10120951 06/19/2023
Mesa Marin Chevron
11101 Highway 178 Bakersfield 93306
Nwestco LLC (800) 339-9930
2209 Zeus Court, Bakersfield, CA 93308
Brandon Nunez
1073967
10226373 09/06/2024
VeederRoot TLS-3XX Technician - C32655 10/11/2024
Vaporless Manufacturing Inc.10/21/2024
OPW - 1193585 04/14/2025
06/19/2023 6
Underground Storage Tank
Monitoring System Certification Form
Page 2 of 6
5. MONITORING SYSTEM AND PROGRAMMING
A separate Monitoring System Certification Form must be prepared for each control panel.
Make of Monitoring System
Control Panel
Model of Monitoring System
Control Panel
Software Version Installed
Attach the post-certification reports if the monitoring system is capable of generating
either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA
All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆
Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆
Are the audible and visual alarms operational? ܆܆܆܆
All sensors have been: 1) visually inspected for wiring kinks, breaks and residual
buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆
Are all sensors installed to detect a release at the earliest opportunity in the
secondary containment? ܆܆܆܆܆܆
The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆
Was the monitoring control panel’s backup battery visually inspected, functionally
tested, and confirmed operational? ܆܆܆܆܆܆
Does the flow of fuel stop at the dispenser if a release is detected in the under-
dispenser containment? ܆܆܆܆܆܆
Does the turbine automatically shut down if the piping secondary containment
monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆
Does the turbine automatically shut down if the piping secondary containment
monitoring system detects a release? Which sensors initiate positive shut down?
(Check all that apply) ܆ Sump ܆ UDC
܆܆܆܆܆܆
If monitoring system alarms are relayed to a remote monitoring center, is all
communication equipment operational? ܆܆܆܆܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
VeederRoot TLS-350
336.02
Underground Storage Tank
Monitoring System Certification Form
Page 3 of 6
6. SENSOR TESTING RESULTS
List only sensors tested on date of this certification. List “Sensor ID” as labeled in system
programming. Additional copies of this page may be attached to accommodate all sensors tested.
Sensor ID Sensor Model Component(s) Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
L1 208/304 Dispenser 1-2
L2 208/304 Dispenser 3-4
L3 208/304 Dispenser 5-6
L4 208/304 Dispenser 7-8
L5 208/304 Dispenser 9-10
L6 208/304 Dispenser 11-12
L7 208/304 87 Unleaded STP
L8 208/304 87 Unleaded Fill
L9 208/304 91 Premium STP
L10 208/304 91 Premium Fill
L11 208/304 Diesel STP
L12 208/304 Diesel Fill
L13 208/304 Vent Box
Underground Storage Tank
Monitoring System Certification Form
Page 4 of 6
7. LINE LEAK DETECTOR TESTING
܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.)
Simulated release rate verified: (Check all that apply.)
܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA
Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆
For emergency generator tank systems, does the LLD create an audible and visual
alarm when a leak is detected? ܆܆ ܆܆ ܆܆
For mechanical LLDs, does the LLD restrict the flow through the pipe when a
release is detected? ܆܆ ܆܆ ܆܆
For electronic LLDs, does the turbine automatically shut off when a release is
detected? ܆܆ ܆܆ ܆܆
For electronic LLDs, does the turbine automatically shut off if any portion of the
monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆
For electronic LLDs, does the turbine automatically shut off if any portion of the
monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆
For electronic LLDs, have all accessible wiring connections been visually inspected
for kinks and breaks? ܆܆ ܆܆ ܆܆
Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆
Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆
LLD ID LLD Model Lines Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
T1 FX1V 87 Unleaded
T2 FX1V 91 Premium
T3 FX1DV Diesel
Underground Storage Tank
Monitoring System Certification Form
Page 5 of 6
8. IN-TANK GAUGING TESTING
܆܆ Check this box if tank gauging is used only for inventory control.
܆܆ Check this box if NO tank gauging equipment is installed.
(Do not complete this section if either box is checked.)
Yes No NA
All wiring has been: 1) visually inspected for kinks, breaks and proper entry and
termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆
Were all in-tank gauging probes visually inspected for damage and residue buildup
to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆
Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆
Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆
Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆
Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆
Probe ID Probe Model Tanks Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
9. COMMENTS
Describe all answers marked “No” or “Fail” and proposed remedy.
List all monitoring equipment either replaced or repaired.
܆܆
All liquid sensors are linked together via VeederRoot 2 to 1 Sensor Input Box 857390-102.
Underground Storage Tank
Monitoring System Certification Form
Page 6 of 6
10. MONITORING SITE PLAN
Date site plan was prepared:
If a site plan has been prepared that shows all required information, you may include it, rather than this page,
with your Monitoring System Certification Form. The site plan must show the general layout of tanks and
identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include
a legend for all symbols depicted.
06/19/2023
APPENDIX C-10
SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,' 6KHDU9DOYH7\SH3URGXFW9DSRU,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//& Mesa Marin Chevron11101 Highway 178Bakersfield101209513-47-8 11-12MPDMPDMPDMPDMPDMPD1-25-69-10ProductProductProductProductProductProductBrandon Nunez
Appendix VIII
Underground Storage Tank
Spill Container Testing Report Form
CERS = California Environmental Reporting System, ID = Identification, ICC = International Code
Council
Page 1 of 2
TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month
1. FACILITY INFORMATION
CERS ID
Test Date
Facility Name
Facility Address
City
ZIP Code
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Test
Phone
Mailing Address
Service Technician Performing Test
Contractor/Tank Tester License Number
ICC Number
ICC Expiration Date
3. TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
4. TEST PROCEDURE INFORMATION
Test Procedures Used Components Tested
5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that each spill container was tested in accordance with California Code of
Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting
documentation is attached; and all information contained herein is accurate. I understand
that test procedures shall be made available upon request by the governing authority.
Service Technician Signature Date
Total # of Pages
10120951 06/19/2023
Mesa Marin Chevron
11101 Highway 178 Bakersfield 93306
Nwestco LLC (800) 339-9930
2209 Zeus Court, Bakersfield, CA 93308
Brandon Nunez
1073967
10226373 09/06/2024
OPW - 1193585 04/14/2025
PEI 1200 1 Hour Hydrostatic All Spill Buckets
06/19/2023 2
Underground Storage Tank
Spill Container Testing Report Form
Additional copies of this page may be attached.
Page 2 of 2
6. SPILL CONTAINER DETAILS
Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer
Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic
Tank ID
Spill Container Manufacturer:
Method of Cathodic Protection ܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
Is the spill container minimum
capacity five gallons excluding
riser volume?
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
Method to keep spill container
empty
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
Spill Container Test Results ܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
Tank ID
Spill Container Manufacturer:
Method of Cathodic Protection ܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
Is the spill container minimum
capacity five gallons excluding
riser volume?
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
Method to keep spill container
empty
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
Spill Container Test Results ܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
1 8. COMMENTS
Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy.
* Mark here if:
Spill containers do not have a minimum capacity of five gallons and require replacement.
T1: 87 UNL
OPW
T2: 91 PNL
OPW
T3: Diesel
OPW
Mesa Chevron System Setup
Responses Received:
200
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
JUN 19, 2023 12:59 PM
TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE
1 UNLEADED 8641 64.63 0.0 84.7 3391
2 SUPREME 3895 34.44 0.0 81.7 8137
3 DIESEL 4193 36.27 0.0 82.6 7882
I90500
JUN 19, 2023 12:59 PM
SOFTWARE REVISION LEVEL
VERSION 336.02
SOFTWARE# 346336-100-C
CREATED - 21.02.13.11.53
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
ISD/APM
I50500
JUN 19, 2023 12:59 PM
SYSTEM TYPE AND LANGUAGE FLAG
SYSTEM UNITS
U.S.
SYSTEM LANGUAGE
ENGLISH
SYSTEM DATE/TIME FORMAT
MON DD YYYY HH:MM:SS xM
I50201
JUN 19, 2023 12:59 PM
SHIFT TIME 1 : 1:00 AM
I50202
JUN 19, 2023 12:59 PM
SHIFT TIME 2 : DISABLED
I50203
JUN 19, 2023 12:59 PM
SHIFT TIME 3 : DISABLED
I50204
JUN 19, 2023 12:59 PM
SHIFT TIME 4 : DISABLED
I54600
JUN 19, 2023 12:59 PM
TANK PER TST NEEDED WRN: DISABLED
I54900
JUN 19, 2023 12:59 PM
TANK ANN TST NEEDED WRN: DISABLED
I55300
JUN 19, 2023 12:59 PM
LINE RE-ENABLE METHOD
PASS LINE TEST
I55600
JUN 19, 2023 12:59 PM
LINE PER TST NEEDED WRN: DISABLED
I55900
JUN 19, 2023 12:59 PM
LINE ANN TST NEEDED WRN: DISABLED
I50D00
JUN 19, 2023 12:59 PM
PRINT TC VOLUMES
ENABLED
I50E00
JUN 19, 2023 12:59 PM
TEMP COMPENSATION
VALUE (DEG F ): 60.0
I60B00
JUN 19, 2023 12:59 PM
STICK HEIGHT OFFSET ENABLE STATUS
DISABLED
I51400
JUN 19, 2023 12:59 PM
H-PROTOCOL DATA FORMAT
HEIGHT
I51A01
JUN 19, 2023 12:59 PM
DAYLIGHT SAVING TIME
ENABLED ON
I51B00
JUN 19, 2023 12:59 PM
DAYLIGHT SAVING TIME
START DATE MAR WEEK 2 SUN 2:00 AM
END DATE NOV WEEK 1 SUN 2:00 AM
I51600
JUN 19, 2023 12:59 PM
RE-DIRECT LOCAL PRINTOUT
DISABLED
I50400
JUN 19, 2023 12:59 PM
232 SECURITY CODE
PORT SECURITY CODE STATUS
1 000000 DISABLED
2 000000 DISABLED
3 000000 DISABLED
4 000000 DISABLED
5 000000 DISABLED
6 000000 DISABLED
I21900
JUN 19, 2023 12:59 PM
TANK CHART SECURITY
DISABLED
I5BD00
JUN 19, 2023 12:59 PM
CUSTOM ALARM LABELS
DISABLED
I56000
JUN 19, 2023 12:59 PM
MASS/DENSITY
DISABLED
I88101
JUN 19, 2023 12:59 PM
PORT SETTINGS:
COMM BOARD : 1 (EDIM )
RS-232 SECURITY
CODE : DISABLED
I88102
JUN 19, 2023 12:59 PM
PORT SETTINGS:
COMM BOARD : 2 (RS-232)
BAUD RATE : 9600
PARITY : NONE
STOP BIT : 2 STOP
DATA LENGTH: 8 DATA
RS-232 SECURITY
CODE : DISABLED
I88103
JUN 19, 2023 12:59 PM
PORT SETTINGS:
COMM BOARD : 3 (S-SAT )
BAUD RATE : 9600
PARITY : NONE
STOP BIT : 2 STOP
DATA LENGTH: 8 DATA
RS-232 SECURITY
CODE : DISABLED
DTR NORMAL STATE: HIGH
I88104
JUN 19, 2023 12:59 PM
I88105
JUN 19, 2023 12:59 PM
I88106
JUN 19, 2023 12:59 PM
I52000
JUN 19, 2023 12:59 PM
RECEIVER AUTO DIAL TYPE & START TIME
RCVR LOCATION LABEL DIAL TYPE START TIME
1 WEEKLY SUN 4:52 PM
2 WEEKLY SUN 4:52 PM
3 WEEKLY SUN 4:52 PM
4 WEEKLY SUN 4:52 PM
5 WEEKLY SUN 4:52 PM
6 WEEKLY SUN 4:52 PM
7 WEEKLY SUN 4:52 PM
8 VEEDER ROOT (FMS) WEEKLY FRI 4:51 PM
I60100
JUN 19, 2023 12:59 PM
TANK CONFIGURATION
DEVICE LABEL CONFIGURED
1 UNLEADED ON
2 SUPREME ON
3 DIESEL ON
4 OFF
I60200
JUN 19, 2023 12:59 PM
TANK PRODUCT LABEL
TANK PRODUCT LABEL
1 UNLEADED
2 SUPREME
3 DIESEL
4
I60300
JUN 19, 2023 12:59 PM
TANK PRODUCT CODE
TANK PRODUCT LABEL
1 UNLEADED 1
2 SUPREME 2
3 DIESEL 3
4 4
I60900
JUN 19, 2023 12:59 PM
TANK THERMAL COEFFICIENT
TANK PRODUCT LABEL
1 UNLEADED 0.000700
2 SUPREME 0.000700
3 DIESEL 0.000450
4 0.000000
I60700
JUN 19, 2023 12:59 PM
TANK DIAMETER
TANK PRODUCT LABEL INCHES
1 UNLEADED 95.75
2 SUPREME 95.75
3 DIESEL 95.75
4 0.00
I60A00
JUN 19, 2023 12:59 PM
TANK FULL VOLUME
TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT
12032 2 SUPREME 1 PT 12032 3 DIESEL
1 PT 12075 4 1 PT 0
I60400
JUN 19, 2023 12:59 PM
TANK FULL VOLUME
TANK PRODUCT LABEL GALLONS
1 UNLEADED 12032
2 SUPREME 12032
3 DIESEL 12075
4 0
I60500
JUN 19, 2023 12:59 PM
TANK 4 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 UNLEADED 12032 0 0 0
2 SUPREME 12032 0 0 0
3 DIESEL 12075 0 0 0
4 0 0 0 0
I60600
JUN 19, 2023 12:59 PM
TANK 20 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 UNLEADED 12032 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2 SUPREME 12032 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
3 DIESEL 12075 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
4 0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
I61500
JUN 19, 2023 12:59 PM
TANK PRODUCT LABEL METER DATA
1 UNLEADED NO
2 SUPREME NO
3 DIESEL NO
4 NO
I62F00
JUN 19, 2023 12:59 PM
MAG PROBE FLOAT SIZE
TANK PRODUCT LABEL FLOAT SIZE:
1 UNLEADED 4.0 IN. PS
2 SUPREME 4.0 IN. PS
3 DIESEL 4.0 IN.
I62700
JUN 19, 2023 12:59 PM
TANK HIGH WATER WARNING LIMIT
TANK PRODUCT LABEL INCHES
1 UNLEADED 2.0
2 SUPREME 2.0
3 DIESEL 2.0
I64200
JUN 19, 2023 12:59 PM
WATER ALARM FILTER
TANK PRODUCT LABEL
1 UNLEADED LOW
2 SUPREME LOW
3 DIESEL LOW
I62400
JUN 19, 2023 12:59 PM
TANK HIGH WATER LEVEL LIMIT
TANK PRODUCT LABEL INCHES
1 UNLEADED 3.0
2 SUPREME 3.0
3 DIESEL 3.0
I62800
JUN 19, 2023 12:59 PM
TANK MAXIMUM VOLUME LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 12032
2 SUPREME 12032
3 DIESEL 12075
4 0
I62300
JUN 19, 2023 12:59 PM
TANK OVERFILL LEVEL LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 10829
2 SUPREME 10829
3 DIESEL 10868
4 0
I62200
JUN 19, 2023 12:59 PM
TANK HIGH PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 11430
2 SUPREME 11430
3 DIESEL 11471
4 0
I62900
JUN 19, 2023 12:59 PM
TANK DELIVERY REQUIRED LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 120
2 SUPREME 120
3 DIESEL 121
4 0
I62100
JUN 19, 2023 12:59 PM
TANK LOW PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 500
2 SUPREME 500
3 DIESEL 500
4 0
I62600
JUN 19, 2023 12:59 PM
TANK LEAK ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 99
2 SUPREME 99
3 DIESEL 99
4 99
I62500
JUN 19, 2023 12:59 PM
TANK SUDDEN LOSS LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 99
2 SUPREME 99
3 DIESEL 99
4 99
I60800
JUN 19, 2023 12:59 PM
TANK TILT
TANK PRODUCT LABEL INCHES
1 UNLEADED 0.00
2 SUPREME 0.00
3 DIESEL 0.00
4 0.00
I60B00
JUN 19, 2023 12:59 PM
STICK HEIGHT OFFSET ENABLE STATUS
DISABLED
I60C00
JUN 19, 2023 12:59 PM
TANK STICK HEIGHT OFFSET
TANK PRODUCT LABEL INCHES
1 UNLEADED 0.00
2 SUPREME 0.00
3 DIESEL 0.00
4 0.00
I61200
JUN 19, 2023 12:59 PM
TANK MANIFOLDED PARTNERS
TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS
1 UNLEADED NONE NONE
2 SUPREME NONE NONE
3 DIESEL NONE NONE
4 NONE NONE
I63600
JUN 19, 2023 12:59 PM
PERIODIC LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 UNLEADED 120
2 SUPREME 120
3 DIESEL 120
4 0
I62A00
JUN 19, 2023 12:59 PM
ANNUAL LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 UNLEADED 120
2 SUPREME 120
3 DIESEL 120
4 0
I62C00
JUN 19, 2023 12:59 PM
TANK PERIODIC TEST TYPE
TANK PRODUCT LABEL PERIODIC TEST TYPE
1 UNLEADED STANDARD
2 SUPREME STANDARD
3 DIESEL STANDARD
4 STANDARD
I62D00
JUN 19, 2023 12:59 PM
TANK LEAK TEST FAIL ALARMS
TANK PRODUCT LABEL
1 UNLEADED GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
2 SUPREME GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
3 DIESEL GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
4 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
I63100
JUN 19, 2023 12:59 PM
TANK LEAK TEST AVERAGING
TANK PRODUCT LABEL ANNUAL PERIODIC
1 UNLEADED OFF OFF
2 SUPREME OFF OFF
3 DIESEL OFF OFF
4 OFF OFF
I63000
JUN 19, 2023 12:59 PM
IN-TANK LEAK TEST NOTIFY
TANK PRODUCT LABEL TANK TEST NOTIFY:
1 UNLEADED OFF
2 SUPREME OFF
3 DIESEL OFF
4 OFF
I63200
JUN 19, 2023 12:59 PM
TANK TEST SIPHON BREAK
TANK PRODUCT LABEL SIPHON BREAK
1 UNLEADED OFF
2 SUPREME OFF
3 DIESEL OFF
4 OFF
I61000
JUN 19, 2023 12:59 PM
TANK DELIVERY DELAY
TANK PRODUCT LABEL
1 UNLEADED 1
2 SUPREME 1
3 DIESEL 1
4 1
I63A00
JUN 19, 2023 12:59 PM
LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD
TANK PRODUCT LABEL PUMP THRESHOLD
1 UNLEADED 10.00%
2 SUPREME 10.00%
3 DIESEL 10.00%
4 10.00%
I61100
JUN 19, 2023 12:59 PM
LEAK TEST METHOD
- - - - - - - - - - - -
TEST ON DATE : ALL TANK
JAN 2, 2019
START TIME : 2:00 AM
TEST RATE :0.20 GAL/HR
DURATION : 2 HOURS
TST EARLY STOP:ENABLED
I61300
JUN 19, 2023 12:59 PM
CSLD PROBABLITY OF DETECTION
I61400
JUN 19, 2023 12:59 PM
CSLD CLIMATE FACTOR
I61600
JUN 19, 2023 12:59 PM
TANK PRODUCT LABEL CAL UPDATE
1 UNLEADED IMMEDIATE
2 SUPREME IMMEDIATE
3 DIESEL IMMEDIATE
4 IMMEDIATE
I61A00
JUN 19, 2023 12:59 PM
IN-TANK LEAK TEST EARLY STOP
TANK PRODUCT LABEL TST EARLY STOP:
1 UNLEADED ENABLED
2 SUPREME ENABLED
3 DIESEL ENABLED
4 ENABLED
I61B00
JUN 19, 2023 12:59 PM
IN-TANK LEAK GROSS TEST AUTO-CONFIRM
I61C00
JUN 19, 2023 12:59 PM
CSLD REPORT ONLY
I62B00
JUN 19, 2023 12:59 PM
TANK LAST ANNUAL TEST
TANK PRODUCT LABEL DATE
1 UNLEADED ??? 0, 0
2 SUPREME ??? 0, 0
3 DIESEL ??? 0, 0
4 ??? 0, 0
I63300
JUN 19, 2023 1:00 PM
LEAK TEST REPORT FORMAT: NORMAL
I63400
JUN 19, 2023 1:00 PM
RECONCILIATION WARNING LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 0
2 SUPREME 0
3 DIESEL 0
4 0
I63500
JUN 19, 2023 1:00 PM
RECONCILIATION ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 1
2 SUPREME 1
3 DIESEL 1
4 1
I63900
JUN 19, 2023 1:00 PM
ACCU CHART END SHAPE FACTOR
TANK PRODUCT LABEL
1 UNLEADED
END FACTOR: NONE
2 SUPREME
END FACTOR: NONE
3 DIESEL
END FACTOR: NONE
4
END FACTOR: NONE
I78000
JUN 19, 2023 1:00 PM
I77700
JUN 19, 2023 1:00 PM
I77800
JUN 19, 2023 1:00 PM
I78C00
JUN 19, 2023 1:00 PM
I78300
JUN 19, 2023 1:00 PM
I78F00
JUN 19, 2023 1:00 PM
I78700
JUN 19, 2023 1:00 PM
I70200
JUN 19, 2023 1:00 PM
LIQUID LABEL
DEVICE LABEL
1 DISP 1-2
2 DISP 3-4
3 DISP 5-6
4 DISP 7-8
5 DISP 9-10
6 DISP 11-12
7 UNL STP
8 UNL FILL
9 SUPREME STP
10 SUPREME FILL
11 DIESEL STP
12 DIESEL FILL
13 VENT BOX
14
15
16
I70300
JUN 19, 2023 1:00 PM
LIQUID TYPE
SENSOR LOCATION TYPE
1 DISP 1-2 DW SUMP 2-1
2 DISP 3-4 DW SUMP 2-1
3 DISP 5-6 DW SUMP 2-1
4 DISP 7-8 DW SUMP 2-1
5 DISP 9-10 DW SUMP 2-1
6 DISP 11-12 DW SUMP 2-1
7 UNL STP DW SUMP 2-1
8 UNL FILL DW SUMP 2-1
9 SUPREME STP DW SUMP 2-1
10 SUPREME FILL DW SUMP 2-1
11 DIESEL STP DW SUMP 2-1
12 DIESEL FILL DW SUMP 2-1
13 VENT BOX DW SUMP 2-1
14 TRI-STATE (SINGLE FLOAT)
15 TRI-STATE (SINGLE FLOAT)
16 TRI-STATE (SINGLE FLOAT)
I70400
JUN 19, 2023 1:00 PM
LIQUID CATEGORY
SENSOR LOCATION CATEGORY
1 DISP 1-2 DISPENSER PAN
2 DISP 3-4 DISPENSER PAN
3 DISP 5-6 DISPENSER PAN
4 DISP 7-8 DISPENSER PAN
5 DISP 9-10 DISPENSER PAN
6 DISP 11-12 DISPENSER PAN
7 UNL STP STP SUMP
8 UNL FILL OTHER SENSORS
9 SUPREME STP STP SUMP
10 SUPREME FILL OTHER SENSORS
11 DIESEL STP STP SUMP
12 DIESEL FILL OTHER SENSORS
13 VENT BOX OTHER SENSORS
14 OTHER SENSORS
15 OTHER SENSORS
16 OTHER SENSORS
I74200
JUN 19, 2023 1:00 PM
I74300
JUN 19, 2023 1:00 PM
I74400
JUN 19, 2023 1:00 PM
I74700
JUN 19, 2023 1:00 PM
I74800
JUN 19, 2023 1:00 PM
I74900
JUN 19, 2023 1:00 PM
I7BC00
JUN 19, 2023 1:00 PM
I80200
JUN 19, 2023 1:00 PM
I80300
JUN 19, 2023 1:00 PM
I80400
JUN 19, 2023 1:00 PM
I80700
JUN 19, 2023 1:00 PM
RELAY LABEL
DEVICE LABEL
1 UNL
2 SUPREME
3 DIESEL
4 OVERFILL ALARM
I80900
JUN 19, 2023 1:00 PM
RELAY ORIENTATION
RELAY DESIGNATION ORIENTATION
1 UNL NORMALLY OPEN
2 SUPREME NORMALLY OPEN
3 DIESEL NORMALLY OPEN
4 OVERFILL ALARM NORMALLY OPEN
I80B00
JUN 19, 2023 1:00 PM
RELAY TANK ASSIGNMENT
RELAY DESIGNATION TANK
1 UNL 1
2 SUPREME 2
3 DIESEL 3
4 OVERFILL ALARM NONE
I80A00
JUN 19, 2023 1:00 PM
RELAY TYPE
RELAY DESIGNATION TYPE
1 UNL PUMP CONTROL OUTPUT
2 SUPREME PUMP CONTROL OUTPUT
3 DIESEL PUMP CONTROL OUTPUT
4 OVERFILL ALARM STANDARD
I80C00
JUN 19, 2023 1:00 PM
I80800
JUN 19, 2023 1:00 PM
RELAY SETUP REPORT
R 1:UNL
TYPE:
PUMP CONTROL OUTPUT
TANK #: 1
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 6:FUEL ALARM
L 7:FUEL ALARM
L 9:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 6:SHORT ALARM
L 7:SHORT ALARM
L 9:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:FLOW COLLECT FAIL
R 2:SUPREME
TYPE:
PUMP CONTROL OUTPUT
TANK #: 2
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 6:FUEL ALARM
L 7:FUEL ALARM
L 9:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 6:SHORT ALARM
L 7:SHORT ALARM
L 9:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:FLOW COLLECT FAIL
R 3:DIESEL
TYPE:
PUMP CONTROL OUTPUT
TANK #: 3
LIQUID SENSOR ALMS
L 2:FUEL ALARM
L 6:FUEL ALARM
L11:FUEL ALARM
L 2:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L11:SENSOR OUT ALARM
L 2:SHORT ALARM
L 6:SHORT ALARM
L11:SHORT ALARM
R 4:OVERFILL ALARM
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
IN-TANK ALARMS
ALL:OVERFILL ALARM
ALL:HIGH PRODUCT ALARM
ALL:MAX PRODUCT ALARM
I79000
JUN 19, 2023 1:01 PM
EDIM:1 VR:349867-001-D TD:17.02.14.08.38
I79100
JUN 19, 2023 1:01 PM
I72300
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
SMARTSENSOR ASSIGNMENT
DEVICE LABEL CATEGORY
01 DISP 1-2 FM AIR FLOW METER
02 DISP 3-4 FM AIR FLOW METER
03 DISP 5-6 FM AIR FLOW METER
04 DISP 7-8 FM AIR FLOW METER
05 DISP 9-10 FM AIR FLOW METER
06 DISP 11-12 FM AIR FLOW METER
07 DISP 5-6 PS VAPOR PRESSURE
08 ATM ATM P SENSOR
09 UNL TANK VAC SENSOR
10 UNL PRODUCT VAC SENSOR
11 VAPOR RETURN VAC SENSOR
12 SUPREME TANK VAC SENSOR
13 SUPREME PRODUCT VAC SENSOR
14 UNL-SUP VENT VAC SENSOR
15 DIESEL TANK VAC SENSOR
16 DIESEL PRODUCT VAC SENSOR
17 DIESEL VENT VAC SENSOR
18 UNKNOWN
19 UNKNOWN
20 UNKNOWN
21 UNKNOWN
22 UNKNOWN
23 UNKNOWN
24 UNKNOWN
25 UNKNOWN
26 UNKNOWN
27 UNKNOWN
28 UNKNOWN
29 UNKNOWN
30 UNKNOWN
31 UNKNOWN
32 UNKNOWN
33 UNKNOWN
34 UNKNOWN
35 UNKNOWN
36 UNKNOWN
37 UNKNOWN
38 UNKNOWN
39 UNKNOWN
40 UNKNOWN
IV4E00
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
EVR/ISD SETUP
TYPE: BALANCE
IV4F00
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
NOZZLE A/L RANGE
A/L RATIO: 0.95 - 1.15
IV4000
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
VAPOR PROCESSOR TYPE
NONE
IV4700
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
ASSESSMENT TIME
START TIME: 10:00 AM
TIME DELAY MINUTES: 1
IV5200
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
ACCEPT HIGH ORVR: NO
IV4A00
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
ISD HOSE TABLE
HOSE FP FP AFM REL HOSE
ID ID LABEL ID ID LABEL
01 01 01 01 02 BLEND3
02 02 02 01 02 BLEND3
03 03 03 02 02 BLEND3
04 04 04 02 02 BLEND3
05 05 05 03 02 BLEND3
06 06 06 03 02 BLEND3
07 07 07 04 02 BLEND3
08 08 08 04 02 BLEND3
09 09 09 05 02 BLEND3
10 16 10 05 02 BLEND3
11 17 11 06 02 BLEND3
12 18 12 06 02 BLEND3
IV4B00
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
PRODUCT/HOSE MAP TABLE
FP AFID M1/H1 M2/H2 M3/H3 M4/H4
01 01 02/01 09/01 01/01 xx/xx
02 01 02/02 09/02 01/02 xx/xx
03 02 02/03 09/03 01/03 xx/xx
04 02 02/04 09/04 01/04 xx/xx
05 03 02/05 09/05 01/05 xx/xx
06 03 02/06 09/06 01/06 xx/xx
07 04 09/07 01/07 02/07 xx/xx
08 04 02/08 09/08 01/08 xx/xx
09 05 02/09 01/09 09/09 xx/xx
16 05 02/10 09/10 01/10 xx/xx
17 06 02/11 09/11 01/11 xx/xx
18 06 02/12 09/12 01/12 xx/xx
IV4900
JUN 19, 2023 1:01 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
LABEL TABLE
ID LABEL
01 UNASSIGNED
02 BLEND3
03 REGULAR
04 MID GRADE
05 PREMIUM
06 GOLD
07 BRONZE
08 SILVER
09 BLEND2
10 BLEND4
IV1000
JUN 19, 2023 1:01 PM
ISD VERSION: 01.06
Mesa Chevron Pre Alarm History
Responses Received:
I10200
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 4 PROBE / G.T. 164210 164472
2 7SMARTSENSOR BD 505619 507027
3 8SMARTSENSOR BD 39372 39365
4 8SMARTSENSOR BD 39394 39476
5 INTERSTITIAL BD 201554 201955
6 INTERSTITIAL BD 201229 201461
7 UNUSED 4936496 4877361
8 UNUSED 4934375 4877166
9 RELAY BOARD 14978 14978
10 STP SENSE BOARD 33087 33132
11 UNUSED 4945617 4875156
12 UNUSED 4942939 4871907
13 UNUSED 4936532 4870218
14 UNUSED 4936382 4876564
15 UNUSED 4932718 4875936
16 UNUSED 4941032 4870174
COMM 1 ELEC DISP INT. 101260 101332
COMM 2 RS232 SERIAL BD 14914 14912
COMM 3 SERIAL SAT BD 480641 481644
COMM 4 UNUSED 4942232 4875546
COMM 5 UNUSED 4941139 4872687
COMM 6 UNUSED 4935461 4869395
I90200
JUN 19, 2023 1:02 PM
SOFTWARE REVISION LEVEL
VERSION 336.02
SOFTWARE# 346336-100-C
CREATED - 21.02.13.11.53
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
ISD/APM
I11100
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 8:58AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 8:58AM
L10 OTHER SUPREME FILL FUEL ALARM CLEAR 6-19-23 8:35AM
L10 OTHER SUPREME FILL FUEL ALARM ALARM 6-19-23 8:33AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 2:35AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 2:35AM
E 1 OTHER COMMUNICATION ALARM CLEAR 6-19-23 2:10AM
E 1 OTHER COMMUNICATION ALARM ALARM 6-19-23 2:10AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-16-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-16-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-16-23 11:06AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-16-23 11:06AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-14-23 11:05AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-14-23 11:05AM
E 1 OTHER COMMUNICATION ALARM CLEAR 6-14-23 10:40AM
E 1 OTHER COMMUNICATION ALARM ALARM 6-14-23 10:40AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-09-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-09-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-07-23 6:37AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-07-23 6:37AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-05-23 6:35AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-05-23 6:35AM
E 1 OTHER COMMUNICATION ALARM CLEAR 6-05-23 6:11AM
E 1 OTHER COMMUNICATION ALARM ALARM 6-05-23 6:10AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-02-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-02-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-31-23 2:28AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-31-23 2:28AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-29-23 2:27AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-29-23 2:27AM
E 1 OTHER COMMUNICATION ALARM CLEAR 5-29-23 2:02AM
E 1 OTHER COMMUNICATION ALARM ALARM 5-29-23 2:02AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-28-23 3:41PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-28-23 3:41PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-26-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-26-23 5:16PM
L 8 OTHER UNL FILL FUEL ALARM CLEAR 5-26-23 3:15PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-24-23 2:26AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-24-23 2:26AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-22-23 2:25AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-22-23 2:25AM
E 1 OTHER COMMUNICATION ALARM CLEAR 5-22-23 2:01AM
E 1 OTHER COMMUNICATION ALARM ALARM 5-22-23 2:00AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-20-23 9:32AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-20-23 9:32AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-19-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-19-23 5:16PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 5-18-23 11:45AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 5-18-23 11:45AM
s14 OTHER UNL-SUP VENT NO VACUUM ALARM CLEAR 5-18-23 11:39AM
I11200
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
SYSTEM PRINTER ERROR CLEAR 6-19-23 10:56AM
SYSTEM PAPER OUT CLEAR 6-19-23 10:56AM
SYSTEM PAPER OUT ALARM 6-19-23 10:55AM
SYSTEM PRINTER ERROR ALARM 6-19-23 10:55AM
SYSTEM PRINTER ERROR CLEAR 6-15-23 12:14AM
SYSTEM PRINTER ERROR ALARM 6-15-23 12:13AM
SYSTEM PAPER OUT CLEAR 6-15-23 12:13AM
SYSTEM PAPER OUT ALARM 6-15-23 12:13AM
SYSTEM PRINTER ERROR CLEAR 5-25-23 5:17AM
SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM
SYSTEM PAPER OUT ALARM 5-25-23 5:17AM
SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM
SYSTEM PRINTER ERROR ALARM 5-25-23 5:17AM
SYSTEM PAPER OUT ALARM 5-25-23 5:17AM
SYSTEM PRINTER ERROR CLEAR 5-09-23 11:39PM
SYSTEM PAPER OUT CLEAR 5-09-23 11:39PM
SYSTEM PRINTER ERROR ALARM 5-09-23 11:38PM
SYSTEM PAPER OUT ALARM 5-09-23 11:38PM
SYSTEM PRINTER ERROR CLEAR 5-08-23 6:23AM
SYSTEM PRINTER ERROR ALARM 5-08-23 6:23AM
SYSTEM PRINTER ERROR CLEAR 4-16-23 11:41PM
SYSTEM PAPER OUT CLEAR 4-16-23 11:41PM
SYSTEM PRINTER ERROR ALARM 4-16-23 11:40PM
SYSTEM PAPER OUT ALARM 4-16-23 11:40PM
SYSTEM PRINTER ERROR CLEAR 2-15-23 7:58PM
SYSTEM PAPER OUT CLEAR 2-15-23 7:58PM
SYSTEM PAPER OUT ALARM 2-15-23 7:57PM
SYSTEM PRINTER ERROR ALARM 2-15-23 7:57PM
SYSTEM PRINTER ERROR CLEAR 2-12-23 3:16AM
SYSTEM PRINTER ERROR ALARM 2-12-23 3:16AM
SYSTEM PAPER OUT CLEAR 2-12-23 3:16AM
SYSTEM PAPER OUT ALARM 2-11-23 10:51PM
L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 12:03PM
L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 12:03PM
L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 10:22AM
L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 10:22AM
SYSTEM PRINTER ERROR CLEAR 1-20-23 11:41PM
SYSTEM PAPER OUT CLEAR 1-20-23 11:41PM
SYSTEM PRINTER ERROR ALARM 1-20-23 11:41PM
SYSTEM PAPER OUT ALARM 1-20-23 11:41PM
OTHER ISD VAPOR LEAK WARN CLEAR 12-07-22 10:03AM
OTHER ISD VAPOR LEAK WARN ALARM 12-06-22 10:03AM
SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM
SYSTEM PAPER OUT CLEAR 11-15-22 7:13AM
SYSTEM PRINTER ERROR ALARM 11-15-22 7:13AM
SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM
SYSTEM PAPER OUT ALARM 11-15-22 7:12AM
SYSTEM PRINTER ERROR ALARM 11-15-22 7:12AM
SYSTEM PRINTER ERROR CLEAR 10-24-22 7:20AM
SYSTEM PAPER OUT CLEAR 10-24-22 7:20AM
I20600
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
TANK ALARM HISTORY
TANK 1 UNLEADED
TANK 2 SUPREME
TANK 3 DIESEL
TANK 5
TANK 6
TANK 7
TANK 8
TANK 9
TANK 10
TANK 11
TANK 12
TANK 13
TANK 14
TANK 15
TANK 16
I38200
JUN 19, 2023 1:02 PM
I30200
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP 1-2
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:17 AM FUEL ALARM
OCT 11, 2022 9:17 AM LOW LIQUID ALARM
2 DISP 3-4
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:17 AM FUEL ALARM
OCT 11, 2022 9:16 AM LOW LIQUID ALARM
3 DISP 5-6
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:18 AM FUEL ALARM
OCT 11, 2022 9:18 AM LOW LIQUID ALARM
4 DISP 7-8
OCT 11, 2022 9:45 AM LOW LIQUID ALARM
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:18 AM FUEL ALARM
5 DISP 9-10
OCT 25, 2022 9:34 PM LOW LIQUID ALARM
OCT 23, 2022 11:02 PM LOW LIQUID ALARM
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
6 DISP 11-12
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:19 AM FUEL ALARM
OCT 11, 2022 9:19 AM LOW LIQUID ALARM
7 UNL STP
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:35 AM FUEL ALARM
OCT 11, 2022 9:35 AM LOW LIQUID ALARM
8 UNL FILL
APR 19, 2023 10:03 AM FUEL ALARM
FEB 7, 2023 12:34 PM LOW LIQUID ALARM
FEB 7, 2023 12:24 PM SENSOR OUT ALARM
9 SUPREME STP
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:34 AM FUEL ALARM
OCT 11, 2022 9:33 AM LOW LIQUID ALARM
10 SUPREME FILL
JUN 19, 2023 8:33 AM FUEL ALARM
FEB 26, 2023 11:33 AM FUEL ALARM
FEB 10, 2023 3:13 PM SENSOR OUT ALARM
11 DIESEL STP
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:31 AM FUEL ALARM
OCT 11, 2022 9:31 AM LOW LIQUID ALARM
12 DIESEL FILL
APR 1, 2023 6:39 PM FUEL ALARM
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:25 AM LOW LIQUID ALARM
13 VENT BOX
NOV 2, 2022 12:44 AM LOW LIQUID ALARM
OCT 11, 2022 9:42 AM SENSOR OUT ALARM
OCT 11, 2022 9:24 AM FUEL ALARM
I31600
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP 1-2 FM
2 DISP 3-4 FM
3 DISP 5-6 FM
4 DISP 7-8 FM
5 DISP 9-10 FM
6 DISP 11-12 FM
7 DISP 5-6 PS
8 ATM
9 UNL TANK
10 UNL PRODUCT
OCT 11, 2022 9:36 AM HIGH LIQUID ALARM
OCT 11, 2022 9:36 AM NO VACUUM ALARM
11 VAPOR RETURN
MAY 18, 2023 11:22 AM NO VACUUM ALARM
OCT 11, 2022 9:36 AM HIGH LIQUID ALARM
OCT 11, 2022 9:36 AM NO VACUUM ALARM
12 SUPREME TANK
MAY 18, 2023 11:32 AM NO VACUUM ALARM
13 SUPREME PRODUCT
DEC 7, 2022 3:10 PM HIGH LIQUID ALARM
OCT 11, 2022 9:34 AM HIGH LIQUID ALARM
OCT 11, 2022 9:34 AM NO VACUUM ALARM
14 UNL-SUP VENT
MAY 18, 2023 9:42 AM NO VACUUM ALARM
MAY 18, 2023 9:41 AM NO VACUUM ALARM
MAY 18, 2023 9:40 AM NO VACUUM ALARM
15 DIESEL TANK
16 DIESEL PRODUCT
OCT 11, 2022 9:32 AM NO VACUUM ALARM
OCT 11, 2022 9:32 AM HIGH LIQUID ALARM
17 DIESEL VENT
OCT 11, 2022 9:32 AM NO VACUUM ALARM
OCT 11, 2022 9:32 AM HIGH LIQUID ALARM
I40200
JUN 19, 2023 1:02 PM
I40300
JUN 19, 2023 1:02 PM
I34200
JUN 19, 2023 1:02 PM
I34700
JUN 19, 2023 1:02 PM
IV0100
JUN 19, 2023 1:02 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
ISD ALARM STATUS REPORT
EVR TYPE: BALANCE
ISD TYPE: 01.06
VAPOR PROCESSOR TYPE: NONE
OVERALL STATUS :PASS EVR VAPOR COLLECTION :NOTEST
EVR VAPOR CONTAINMENT :PASS
ISD MONITOR UP-TIME :100%
EVR/ISD PASS TIME :100%
WARNING ALARMS
DATE TIME DESCRIPTION READING VALUE
22-12-06 10:03:20 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.06
22-10-06 10:03:52 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 38.55
22-10-05 10:03:48 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 37.45
22-10-04 10:03:56 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 33.33
22-10-03 10:03:55 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 32.76
22-10-02 10:03:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.98
22-10-01 10:03:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.95
22-09-30 10:03:11 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 30.32
22-09-24 10:04:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.92
22-09-23 10:03:58 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.91
FAILURE ALARMS
DATE TIME DESCRIPTION READING VALUE
22-10-09 10:03:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 43.37
22-10-08 10:03:42 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.44
22-10-07 10:03:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.38
22-06-11 10:07:00 FLOW PERFORMANCE HOSE BLOCKAGE FP 7 BLEND3
22-03-05 10:07:15 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3
21-09-07 10:07:55 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3
21-08-18 10:08:51 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3
21-07-26 10:05:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 5 BLEND3
21-04-12 10:05:16 FLOW PERFORMANCE HOSE BLOCKAGE FP 9 BLEND3
20-03-11 10:05:46 FLOW PERFORMANCE HOSE BLOCKAGE FP11 BLEND3
SHUTDOWN & MISCELLANEOUS EVENTS
DATE TIME DESCRIPTION ACTION/NAME
23-06-19 11:10:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING
23-06-19 11:10:57 ISD STARTUP
23-06-19 11:07:31 ISD SHUTDOWN
23-06-19 10:07:56 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-18 10:08:10 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-17 10:07:41 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-16 10:08:04 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-15 10:08:27 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-14 10:08:35 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-13 10:08:12 READINESS ISD:PP EVR:NP EVR READINESS PENDING
Mesa Chevron Post Alarm History
Responses Received:
I10200
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 4 PROBE / G.T. 164210 164472
2 7SMARTSENSOR BD 505619 507027
3 8SMARTSENSOR BD 39372 39365
4 8SMARTSENSOR BD 39394 39476
5 INTERSTITIAL BD 201554 201955
6 INTERSTITIAL BD 201229 201461
7 UNUSED 4936496 4877361
8 UNUSED 4934375 4877166
9 RELAY BOARD 14978 14978
10 STP SENSE BOARD 33087 33132
11 UNUSED 4945617 4875156
12 UNUSED 4942939 4871907
13 UNUSED 4936532 4870218
14 UNUSED 4936382 4876564
15 UNUSED 4932718 4875936
16 UNUSED 4941032 4870174
COMM 1 ELEC DISP INT. 101260 101332
COMM 2 RS232 SERIAL BD 14914 14912
COMM 3 SERIAL SAT BD 480641 481644
COMM 4 UNUSED 4942232 4875546
COMM 5 UNUSED 4941139 4872687
COMM 6 UNUSED 4935461 4869395
I90200
JUN 19, 2023 3:37 PM
SOFTWARE REVISION LEVEL
VERSION 336.02
SOFTWARE# 346336-100-C
CREATED - 21.02.13.11.53
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
ISD/APM
I11100
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
s16 OTHER DIESEL PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:34PM
s17 OTHER DIESEL VENT HIGH LIQUID ALARM CLEAR 6-19-23 3:34PM
s16 OTHER DIESEL PRODUCT NO VACUUM ALARM CLEAR 6-19-23 3:34PM
s17 OTHER DIESEL VENT NO VACUUM ALARM CLEAR 6-19-23 3:34PM
s16 OTHER DIESEL PRODUCT NO VACUUM ALARM ALARM 6-19-23 3:33PM
s17 OTHER DIESEL VENT NO VACUUM ALARM ALARM 6-19-23 3:33PM
s17 OTHER DIESEL VENT HIGH LIQUID ALARM ALARM 6-19-23 3:31PM
s16 OTHER DIESEL PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:31PM
s14 OTHER UNL-SUP VENT HIGH LIQUID ALARM CLEAR 6-19-23 3:27PM
s13 OTHER SUPREME PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:27PM
s14 OTHER UNL-SUP VENT NO VACUUM ALARM CLEAR 6-19-23 3:27PM
s13 OTHER SUPREME PRODUCT NO VACUUM ALARM CLEAR 6-19-23 3:27PM
s14 OTHER UNL-SUP VENT NO VACUUM ALARM ALARM 6-19-23 3:26PM
s13 OTHER SUPREME PRODUCT NO VACUUM ALARM ALARM 6-19-23 3:25PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 3:24PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 3:24PM
s14 OTHER UNL-SUP VENT HIGH LIQUID ALARM ALARM 6-19-23 3:23PM
s13 OTHER SUPREME PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:23PM
s11 OTHER VAPOR RETURN HIGH LIQUID ALARM CLEAR 6-19-23 3:22PM
s10 OTHER UNL PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:22PM
s11 OTHER VAPOR RETURN HIGH LIQUID ALARM ALARM 6-19-23 3:22PM
s10 OTHER UNL PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:22PM
s11 OTHER VAPOR RETURN HIGH LIQUID ALARM CLEAR 6-19-23 3:17PM
s10 OTHER UNL PRODUCT HIGH LIQUID ALARM CLEAR 6-19-23 3:17PM
s11 OTHER VAPOR RETURN NO VACUUM ALARM CLEAR 6-19-23 3:16PM
s11 OTHER VAPOR RETURN NO VACUUM ALARM ALARM 6-19-23 3:16PM
s10 OTHER UNL PRODUCT NO VACUUM ALARM CLEAR 6-19-23 3:16PM
s10 OTHER UNL PRODUCT NO VACUUM ALARM ALARM 6-19-23 3:13PM
s11 OTHER VAPOR RETURN HIGH LIQUID ALARM ALARM 6-19-23 3:11PM
s10 OTHER UNL PRODUCT HIGH LIQUID ALARM ALARM 6-19-23 3:11PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-19-23 1:48PM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-19-23 1:48PM
L12 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L10 OTHER SUPREME FILL SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L11 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 9 STP SUMP SUPREME STP SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L13 OTHER VENT BOX SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 8 OTHER UNL FILL SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 7 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 6 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 2 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 3 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 6-19-23 1:42PM
L 8 OTHER UNL FILL SENSOR OUT ALARM ALARM 6-19-23 1:42PM
L 7 STP SUMP UNL STP SENSOR OUT ALARM ALARM 6-19-23 1:42PM
L 6 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 6-19-23 1:42PM
L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 6-19-23 1:42PM
L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 6-19-23 1:42PM
I11200
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
SYSTEM PRINTER ERROR CLEAR 6-19-23 10:56AM
SYSTEM PAPER OUT CLEAR 6-19-23 10:56AM
SYSTEM PAPER OUT ALARM 6-19-23 10:55AM
SYSTEM PRINTER ERROR ALARM 6-19-23 10:55AM
SYSTEM PRINTER ERROR CLEAR 6-15-23 12:14AM
SYSTEM PRINTER ERROR ALARM 6-15-23 12:13AM
SYSTEM PAPER OUT CLEAR 6-15-23 12:13AM
SYSTEM PAPER OUT ALARM 6-15-23 12:13AM
SYSTEM PRINTER ERROR CLEAR 5-25-23 5:17AM
SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM
SYSTEM PAPER OUT ALARM 5-25-23 5:17AM
SYSTEM PAPER OUT CLEAR 5-25-23 5:17AM
SYSTEM PRINTER ERROR ALARM 5-25-23 5:17AM
SYSTEM PAPER OUT ALARM 5-25-23 5:17AM
SYSTEM PRINTER ERROR CLEAR 5-09-23 11:39PM
SYSTEM PAPER OUT CLEAR 5-09-23 11:39PM
SYSTEM PRINTER ERROR ALARM 5-09-23 11:38PM
SYSTEM PAPER OUT ALARM 5-09-23 11:38PM
SYSTEM PRINTER ERROR CLEAR 5-08-23 6:23AM
SYSTEM PRINTER ERROR ALARM 5-08-23 6:23AM
SYSTEM PRINTER ERROR CLEAR 4-16-23 11:41PM
SYSTEM PAPER OUT CLEAR 4-16-23 11:41PM
SYSTEM PRINTER ERROR ALARM 4-16-23 11:40PM
SYSTEM PAPER OUT ALARM 4-16-23 11:40PM
SYSTEM PRINTER ERROR CLEAR 2-15-23 7:58PM
SYSTEM PAPER OUT CLEAR 2-15-23 7:58PM
SYSTEM PAPER OUT ALARM 2-15-23 7:57PM
SYSTEM PRINTER ERROR ALARM 2-15-23 7:57PM
SYSTEM PRINTER ERROR CLEAR 2-12-23 3:16AM
SYSTEM PRINTER ERROR ALARM 2-12-23 3:16AM
SYSTEM PAPER OUT CLEAR 2-12-23 3:16AM
SYSTEM PAPER OUT ALARM 2-11-23 10:51PM
L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 12:03PM
L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 12:03PM
L 8 OTHER UNL FILL SETUP DATA WARNING CLEAR 2-07-23 10:22AM
L 8 OTHER UNL FILL SETUP DATA WARNING ALARM 2-07-23 10:22AM
SYSTEM PRINTER ERROR CLEAR 1-20-23 11:41PM
SYSTEM PAPER OUT CLEAR 1-20-23 11:41PM
SYSTEM PRINTER ERROR ALARM 1-20-23 11:41PM
SYSTEM PAPER OUT ALARM 1-20-23 11:41PM
OTHER ISD VAPOR LEAK WARN CLEAR 12-07-22 10:03AM
OTHER ISD VAPOR LEAK WARN ALARM 12-06-22 10:03AM
SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM
SYSTEM PAPER OUT CLEAR 11-15-22 7:13AM
SYSTEM PRINTER ERROR ALARM 11-15-22 7:13AM
SYSTEM PRINTER ERROR CLEAR 11-15-22 7:13AM
SYSTEM PAPER OUT ALARM 11-15-22 7:12AM
SYSTEM PRINTER ERROR ALARM 11-15-22 7:12AM
SYSTEM PRINTER ERROR CLEAR 10-24-22 7:20AM
SYSTEM PAPER OUT CLEAR 10-24-22 7:20AM
I20600
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
TANK ALARM HISTORY
TANK 1 UNLEADED
TANK 2 SUPREME
TANK 3 DIESEL
TANK 5
TANK 6
TANK 7
TANK 8
TANK 9
TANK 10
TANK 11
TANK 12
TANK 13
TANK 14
TANK 15
TANK 16
I38200
JUN 19, 2023 3:37 PM
I30200
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP 1-2
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:31 PM LOW LIQUID ALARM
JUN 19, 2023 1:31 PM FUEL ALARM
2 DISP 3-4
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:34 PM LOW LIQUID ALARM
JUN 19, 2023 1:33 PM FUEL ALARM
3 DISP 5-6
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:29 PM LOW LIQUID ALARM
JUN 19, 2023 1:28 PM FUEL ALARM
4 DISP 7-8
JUN 19, 2023 1:42 PM SENSOR OUT ALARM
JUN 19, 2023 1:30 PM LOW LIQUID ALARM
JUN 19, 2023 1:29 PM FUEL ALARM
5 DISP 9-10
JUN 19, 2023 1:42 PM SENSOR OUT ALARM
JUN 19, 2023 1:25 PM LOW LIQUID ALARM
JUN 19, 2023 1:25 PM FUEL ALARM
6 DISP 11-12
JUN 19, 2023 1:42 PM SENSOR OUT ALARM
JUN 19, 2023 1:27 PM LOW LIQUID ALARM
JUN 19, 2023 1:26 PM FUEL ALARM
7 UNL STP
JUN 19, 2023 1:42 PM SENSOR OUT ALARM
JUN 19, 2023 1:14 PM LOW LIQUID ALARM
JUN 19, 2023 1:13 PM FUEL ALARM
8 UNL FILL
JUN 19, 2023 1:42 PM SENSOR OUT ALARM
JUN 19, 2023 1:22 PM LOW LIQUID ALARM
JUN 19, 2023 1:14 PM FUEL ALARM
9 SUPREME STP
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:12 PM LOW LIQUID ALARM
JUN 19, 2023 1:12 PM FUEL ALARM
10 SUPREME FILL
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:22 PM LOW LIQUID ALARM
JUN 19, 2023 1:15 PM FUEL ALARM
11 DIESEL STP
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:11 PM LOW LIQUID ALARM
JUN 19, 2023 1:11 PM FUEL ALARM
12 DIESEL FILL
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:22 PM LOW LIQUID ALARM
JUN 19, 2023 1:16 PM FUEL ALARM
13 VENT BOX
JUN 19, 2023 1:41 PM SENSOR OUT ALARM
JUN 19, 2023 1:17 PM FUEL ALARM
NOV 2, 2022 12:44 AM LOW LIQUID ALARM
I31600
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP 1-2 FM
2 DISP 3-4 FM
3 DISP 5-6 FM
4 DISP 7-8 FM
5 DISP 9-10 FM
6 DISP 11-12 FM
7 DISP 5-6 PS
8 ATM
9 UNL TANK
10 UNL PRODUCT
JUN 19, 2023 3:22 PM HIGH LIQUID ALARM
JUN 19, 2023 3:13 PM NO VACUUM ALARM
JUN 19, 2023 3:11 PM HIGH LIQUID ALARM
11 VAPOR RETURN
JUN 19, 2023 3:22 PM HIGH LIQUID ALARM
JUN 19, 2023 3:16 PM NO VACUUM ALARM
JUN 19, 2023 3:11 PM HIGH LIQUID ALARM
12 SUPREME TANK
MAY 18, 2023 11:32 AM NO VACUUM ALARM
13 SUPREME PRODUCT
JUN 19, 2023 3:25 PM NO VACUUM ALARM
JUN 19, 2023 3:23 PM HIGH LIQUID ALARM
DEC 7, 2022 3:10 PM HIGH LIQUID ALARM
14 UNL-SUP VENT
JUN 19, 2023 3:26 PM NO VACUUM ALARM
JUN 19, 2023 3:23 PM HIGH LIQUID ALARM
MAY 18, 2023 9:42 AM NO VACUUM ALARM
15 DIESEL TANK
16 DIESEL PRODUCT
JUN 19, 2023 3:33 PM NO VACUUM ALARM
JUN 19, 2023 3:31 PM HIGH LIQUID ALARM
OCT 11, 2022 9:32 AM NO VACUUM ALARM
17 DIESEL VENT
JUN 19, 2023 3:33 PM NO VACUUM ALARM
JUN 19, 2023 3:31 PM HIGH LIQUID ALARM
OCT 11, 2022 9:32 AM NO VACUUM ALARM
I40200
JUN 19, 2023 3:37 PM
I40300
JUN 19, 2023 3:37 PM
I34200
JUN 19, 2023 3:37 PM
I34700
JUN 19, 2023 3:37 PM
IV0100
JUN 19, 2023 3:37 PM
175900 MESA MARIN CH
PIT STOP MARKET
11101 HWY. 178
BAKERSFIELD,CA 93306
ISD ALARM STATUS REPORT
EVR TYPE: BALANCE
ISD TYPE: 01.06
VAPOR PROCESSOR TYPE: NONE
OVERALL STATUS :PASS EVR VAPOR COLLECTION :NOTEST
EVR VAPOR CONTAINMENT :PASS
ISD MONITOR UP-TIME :100%
EVR/ISD PASS TIME :100%
WARNING ALARMS
DATE TIME DESCRIPTION READING VALUE
22-12-06 10:03:20 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.06
22-10-06 10:03:52 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 38.55
22-10-05 10:03:48 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 37.45
22-10-04 10:03:56 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 33.33
22-10-03 10:03:55 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 32.76
22-10-02 10:03:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.98
22-10-01 10:03:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 31.95
22-09-30 10:03:11 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 30.32
22-09-24 10:04:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.92
22-09-23 10:03:58 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.91
FAILURE ALARMS
DATE TIME DESCRIPTION READING VALUE
22-10-09 10:03:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 43.37
22-10-08 10:03:42 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.44
22-10-07 10:03:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.38
22-06-11 10:07:00 FLOW PERFORMANCE HOSE BLOCKAGE FP 7 BLEND3
22-03-05 10:07:15 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3
21-09-07 10:07:55 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3
21-08-18 10:08:51 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3
21-07-26 10:05:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 5 BLEND3
21-04-12 10:05:16 FLOW PERFORMANCE HOSE BLOCKAGE FP 9 BLEND3
20-03-11 10:05:46 FLOW PERFORMANCE HOSE BLOCKAGE FP11 BLEND3
SHUTDOWN & MISCELLANEOUS EVENTS
DATE TIME DESCRIPTION ACTION/NAME
23-06-19 11:10:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING
23-06-19 11:10:57 ISD STARTUP
23-06-19 11:07:31 ISD SHUTDOWN
23-06-19 10:07:56 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-18 10:08:10 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-17 10:07:41 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-16 10:08:04 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-15 10:08:27 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-14 10:08:35 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-06-13 10:08:12 READINESS ISD:PP EVR:NP EVR READINESS PENDING