HomeMy WebLinkAboutFMC 2023IMPACT VALVE LEAK DETECTOR LINE TEST MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 10/12/2023 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR KRIS KARNS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 10/10/2023 Order Number: 3462739 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: SAM'S CLUB # 4819 (SC4819) 5625 GOSFORD ROAD BAKERSFIELD, CA 93313 In an effort to keep all our record keeping and reporting requirements as current as possible, Tanknology kindly requests you notify Dawn Kohlmeyer in writing at dkohlmeyer@tanknology.com when your CUPA requires all records to be submitted electronically via the CERS database. Your assistance in this endeavor is greatly appreciated. Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 3462739 Date: 10/10/2023 Site Name/ID: SAM'S CLUB # 4819 / SC4819 Address: 5625 GOSFORD ROAD City: BAKERSFIELD State: CA Zip: 93313 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 UNLEADED Pressure 50 12:15 12:45 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 UNLEADED Pressure 50 12:15 12:45 0.00 Pass Yes Tank # 3 Line # 1 VacuTect 3 PREMIUM Pressure 50 12:15 12:45 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 4 DIESEL2 Pressure 50 12:15 12:45 0.00 Pass Yes Tank # Line # Tank # Line # Technician Comments: Technician Name:Patrick Pfrang Certification #:1590 exp: 5/31/2026 Technician Signature: Environmental Compliance for Petroleum Systems ©2023 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3462739 Date:10/10/2023 Site Name / ID:SAM'S CLUB # 4819 / SC4819 Address:5625 GOSFORD ROAD City:BAKERSFIELD State:CA Zip:93313 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results 1 REG UNLEADED 1 8 Existing Mechanical Red Jacket FX1V 307098751 36.00 189.0 3.00 18.00 140.00 10 3 Pass 2 REG UNLEADED 1 16 Existing Mechanical Red Jacket FX1V 307098752 37.00 189.0 3.00 18.00 140.00 11 4 Pass 3 PREMIUM PREMIUM 1 8 Existing Mechanical Red Jacket FX1V 104192098 37.00 189.0 3.00 18.00 200.00 12 5 Pass 4 DIESEL DIESEL2 1 8 Existing Mechanical Red Jacket FX1DV 111136174 28.00 189.0 3.00 18.00 105.00 8 9 Pass Technician Comments: Technician Name:Patrick Pfrang Certification #:44637 Technician Signature:Expire Date:3/9/2025 Environmental Compliance for Petroleum Systems © 2023 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3462739 Date:10/10/2023 Site Name/ID:SAM'S CLUB # 4819 Address:5625 GOSFORD ROAD City:BAKERSFIELD State:CA Zip:93313 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 87 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 87 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 87 Pass Fail Not Tested 13/14 91 Pass Fail Not Tested 15/16 40 Pass Fail Not Tested 15/16 87 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested Technician Comments: Technician Name:Patrick Pfrang Signature: Environmental Compliance for Petroleum Systems ©2023 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, Tx 78759 Patrick Pfrang 10027021 10/10/2023 SAM'S CLUB # 4819 5625 GOSFORD ROAD BAKERSFIELD 93313 Class A General Engineering 743160 8202676 01/27/2025 08/23/2025 10/27/2024 10/10/2023 6 Veeder Root:ATG Technician (A29052) VMI:TLDT-5000 Tester (1314) Veeder Root TLS-350 336.02 L1 UNLD T1 INT SPACE L2 L3 UNLD T1 STP SUMP L4 L5 L6 L7 PREM/DIES T3/T4 INT L8 L9 PREM T3 STP SUMP L10 L11 L12 UDC FP 3-4 L13 UDC FP 5-6 L14 UDC FP 7-8 L15 UDC FP 11-12 L16 UDC FP 13-14 L17 UDC FP 15-16 L18 VENT BOX L19 L20 UDC FP 9-10 s1 87 N PRODUCT s2 87 N VENT -HIRT LINE s3 87 S PRODUCT 87 S VENTs4 794380-303 UNLD T1 FILL SUMP UNLD T2 INT SPACE UNLD T2 FILL SUMP UNLD T2 STP SUMP PREM T3 FILL SUMP DIES T4 FILL SUMP DIES T4 STP SUMP UDC FP 1-2 794380-208/304 794380-208/304 794380-303 794380-208/304 794380-208/304 794380-303 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 794380-208/304 330020-480 330020-480 330020-485 330020-485 s5 VAPOR RETURN s6 s7 91 PRODUCT NORTH s8 s9 s10 s11 DIESEL VENT 330020-485 91 PRODUCT SOUTH 91 VENT 91 LINE TO VENT BOX DIESEL PRODUCT 330020-486 330020-486 330020-486 330020-486 330020-480 330020-480 T1 T1 UNLEADED T2 T3 PREMIUM T4 DIESEL Red Jacket FX1V T2 UNLEADEDRed Jacket FX1V Red Jacket FX1V Red Jacket FX1DV Replaced the T2 STP L6 794380-304 brine sensor. The sensor was not working. 10/10/2023 10027021 10/10/2023 SAM'S CLUB # 4819 5625 GOSFORD ROAD BAKERSFIELD 93313 Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, TX 78759 Patrick Pfrang 743160 8202676 01/27/2025 03/15/2025 PEI RP 1200 FILL BUCKETS 10/10/2023 2 OPW:EVR Phase 1 T1 87 FILL T2 87 FILL T3 91 FILL T4 DSL FILL OPW OPW OPW OPW SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: SAM'S CLUB # 4819 Date of Testing: 10/10/2023 Facility Address: 5625 GOSFORD ROAD , BAKERSFIELD, CA 93313 Facility Contact: Asset Protection Manager Phone: 661-654-8565 Date Local Agency Was Notified of Testing: 6/6/2023 Name of Local Agency Inspector (if present during testing): Marty Brownfield 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Patrick Pfrang Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank 1 UNLEADED - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 09:08:00 12.50 in. 10:08:00 12.50 in. 1 hr 0.00 in. +/- 9.00 Pass Spill Box # Tank 2 UNLEADED - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 09:08:00 12.50 in. 10:08:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Tank 3 PREMIUM - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 09:08:00 12.50 in. 10:08:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Tank 4 DIESEL2 - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 09:08:00 12.50 in. 10:08:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:10/10/2023 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3462739 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3462739 Site ID / Name:SC4819 / SAM'S CLUB # 4819 Address:5625 GOSFORD ROAD City:BAKERSFIELD State:CA Zip:93313 W.O.# SC1-3462739 +AAE- I50301 OCT 10, 2023 2:12 PM +ACM- 1:281428 +AAM- +AAE- I50302 OCT 10, 2023 2:12 PM +ACM- 2:SAMS CLUB 4819 +AAM- +AAE- I50303 OCT 10, 2023 2:12 PM +ACM- 3:5625 GOSFORD RD. +AAM- +AAE- I50304 OCT 10, 2023 2:12 PM +ACM- 4:BAKERSFIELD CA.93313 +AAM- +AAE- I51700 OCT 10, 2023 2:12 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM +AAM- +AAE- I50F00 OCT 10, 2023 2:12 PM MON DD YYYY HH:MM:SS xM +AAM- +AAE- I10200 OCT 10, 2023 2:12 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 161652 161743 2 INTERSTITIAL BD 200579 200685 3 INTERSTITIAL BD 200670 201007 4 INTERSTITIAL BD 200282 200639 5 8SMARTSENSOR BD 39205 39319 6 8SMARTSENSOR BD 39247 39298 7 7SMARTSENSOR BD 504408 504524 8 UNUSED 4846344 4826151 9 RELAY BOARD 14950 14978 10 RELAY BOARD 14908 14936 11 STP SENSE BOARD 32825 32874 12 COMBO I/O BOARD 9888 9929 13 UNUSED 4854362 4828635 14 UNUSED 4851601 4822700 15 UNUSED 4844100 4824608 16 UNUSED 4845891 4823527 COMM 1 RS232 SERIAL BD 14844 14850 COMM 2 ELEC DISP INT. 100671 100693 COMM 3 SERIAL SAT BD 479730 479956 COMM 4 UNUSED 4849368 4825498 COMM 5 UNUSED 4846312 4819881 COMM 6 UNUSED 4849958 4820008 +AAM- +AAE- I60100 OCT 10, 2023 2:12 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 T1-Unleaded ON 2 T2-Unleaded ON 3 T3-Premium ON 4 T4-Diesel ON +AAM- +AAE- I60200 OCT 10, 2023 2:12 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 T1-Unleaded 2 T2-Unleaded 3 T3-Premium 4 T4-Diesel +AAM- +AAE- I60300 OCT 10, 2023 2:13 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 T1-Unleaded 1 2 T2-Unleaded 1 3 T3-Premium 3 4 T4-Diesel 4 +AAM- +AAE- I60400 OCT 10, 2023 2:13 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 T1-Unleaded 19782 2 T2-Unleaded 19782 3 T3-Premium 11904 4 T4-Diesel 7901 +AAM- +AAE- I60700 OCT 10, 2023 2:13 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 T1-Unleaded 118.38 2 T2-Unleaded 118.38 3 T3-Premium 118.38 4 T4-Diesel 118.38 +AAM- +AAE- I60900 OCT 10, 2023 2:13 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 T1-Unleaded 0.000700 2 T2-Unleaded 0.000700 3 T3-Premium 0.000700 4 T4-Diesel 0.000450 +AAM- +AAE- I61200 OCT 10, 2023 2:13 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 T1-Unleaded 2 NONE 2 T2-Unleaded 1 NONE 3 T3-Premium NONE NONE 4 T4-Diesel NONE NONE +AAM- +AAE- I62100 OCT 10, 2023 2:13 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 T1-Unleaded 800 2 T2-Unleaded 800 3 T3-Premium 800 4 T4-Diesel 536 +AAM- +AAE- I62200 OCT 10, 2023 2:13 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 T1-Unleaded 18793 2 T2-Unleaded 18793 3 T3-Premium 11309 4 T4-Diesel 7506 +AAM- +AAE- I62300 OCT 10, 2023 2:13 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 T1-Unleaded 17804 2 T2-Unleaded 17804 3 T3-Premium 10714 4 T4-Diesel 7111 +AAM- +AAE- I62400 OCT 10, 2023 2:13 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 T1-Unleaded 3.0 2 T2-Unleaded 3.0 3 T3-Premium 3.0 4 T4-Diesel 3.0 +AAM- +AAE- I62800 OCT 10, 2023 2:13 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 T1-Unleaded 19782 2 T2-Unleaded 19782 3 T3-Premium 11904 4 T4-Diesel 7901 +AAM- +AAE- I62900 OCT 10, 2023 2:13 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 T1-Unleaded 0 2 T2-Unleaded 0 3 T3-Premium 1 4 T4-Diesel 0 +AAM- +AAE- I70300 OCT 10, 2023 2:13 PM LIQUID TYPE SENSOR LOCATION TYPE 1 Unld T1 Int Space DUAL POINT HYDROSTATIC 2 Unld T1 Fill Sump DW SUMP 2-1 3 Unld T1 STP Sump DW SUMP 2-1 4 Unld T2 Int Space DUAL POINT HYDROSTATIC 5 Unld T2 Fill Sump DW SUMP 2-1 6 Unld T2 STP Sump DW SUMP 2-1 7 Prem/Dies T3/T4 Int DUAL POINT HYDROSTATIC 8 Prem T3 Fill Sump DW SUMP 2-1 9 Prem T3 STP Sump DW SUMP 2-1 10 Dies T4 Fill Sump DW SUMP 2-1 11 Dies T4 STP Sump DW SUMP 2-1 12 UDC FP 3-4 DW SUMP 2-1 13 UDC FP 5-6 DW SUMP 2-1 14 UDC FP 7-8 DW SUMP 2-1 15 UDC FP 11-12 DW SUMP 2-1 16 UDC FP 13-14 DW SUMP 2-1 17 UDC FP 15-16 DW SUMP 2-1 18 VENT BOX DW SUMP 2-1 19 UDC FP 1-2 DW SUMP 2-1 20 UDC FP 9-10 DW SUMP 2-1 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) +AAM- +AAE- I72100 OCT 10, 2023 2:13 PM SMART SENSOR CONFIGURATION DEVICE LABEL CONFIGURED 1 87 N PRODUCT ON 2 87 N VENT-HIRT LINE ON 3 87 S PRODUCT ON 4 87 S VENT ON 5 VAPOR RETURN ON 6 91 PRODUCT SOUTH ON 7 91 PRODUCT NORTH ON 8 91 VENT ON 9 91 LINE TO VENT BOX ON 10 DIESEL PRODUCT ON 11 DIESEL VENT ON 12 AFM DISP 1-2 ON 13 AFM DISP 3-4 ON 14 AFM DISP 5-6 ON 15 AFM DISP 7-8 ON 16 AFM DISP 9-10 ON 17 AFM DISP 11-12 ON 18 VPS DISP 7-8 ON 19 AFM DISP 13-14 ON 20 AFM DISP 15-16 ON 21 OFF 22 OFF 23 OFF 24 ATM PRESSURE SENSOR ON +AAM- +AAE- I72200 OCT 10, 2023 2:13 PM SMART SENSOR LABEL DEVICE LABEL 1 87 N PRODUCT 2 87 N VENT-HIRT LINE 3 87 S PRODUCT 4 87 S VENT 5 VAPOR RETURN 6 91 PRODUCT SOUTH 7 91 PRODUCT NORTH 8 91 VENT 9 91 LINE TO VENT BOX 10 DIESEL PRODUCT 11 DIESEL VENT 12 AFM DISP 1-2 13 AFM DISP 3-4 14 AFM DISP 5-6 15 AFM DISP 7-8 16 AFM DISP 9-10 17 AFM DISP 11-12 18 VPS DISP 7-8 19 AFM DISP 13-14 20 AFM DISP 15-16 21 22 23 24 ATM PRESSURE SENSOR +AAM- +AAE- I72900 OCT 10, 2023 2:13 PM VACUUM SENSOR PUMP NUMBER DEVICE LABEL PUMP NUMBER 1 87 N PRODUCT R 5:87 NORTH 2 87 N VENT-HIRT LINE R 5:87 NORTH 3 87 S PRODUCT R 6:87 SOUTH 4 87 S VENT R 6:87 SOUTH 5 VAPOR RETURN R 6:87 SOUTH 6 91 PRODUCT SOUTH R 7:91 7 91 PRODUCT NORTH R 7:91 8 91 VENT R 7:91 9 91 LINE TO VENT BOX R 7:91 10 DIESEL PRODUCT R 8:DIESEL 11 DIESEL VENT R 8:DIESEL +AAM- +AAE- I72A00 OCT 10, 2023 2:13 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 1 87 N PRODUCT 43.0 GALLONS 2 87 N VENT-HIRT LINE 20.6 GALLONS 3 87 S PRODUCT 43.4 GALLONS 4 87 S VENT 20.8 GALLONS 5 VAPOR RETURN 94.9 GALLONS 6 91 PRODUCT SOUTH 48.3 GALLONS 7 91 PRODUCT NORTH 48.3 GALLONS 8 91 VENT 25.5 GALLONS 9 91 LINE TO VENT BOX 0.4 GALLONS 10 DIESEL PRODUCT 17.3 GALLONS 11 DIESEL VENT 29.9 GALLONS +AAM- +AAE- I72B00 OCT 10, 2023 2:13 PM VACUUM SENSOR RELIEF VALVE PRESENT DEVICE LABEL RELIEF VALVE 1 87 N PRODUCT NO 2 87 N VENT-HIRT LINE NO 3 87 S PRODUCT NO 4 87 S VENT NO 5 VAPOR RETURN NO 6 91 PRODUCT SOUTH NO 7 91 PRODUCT NORTH NO 8 91 VENT NO 9 91 LINE TO VENT BOX NO 10 DIESEL PRODUCT NO 11 DIESEL VENT NO +AAM- +AAE- I72C00 OCT 10, 2023 2:13 PM VACUUM SENSOR RELIEF VALVE PRESSURE DEVICE LABEL RELIEF VALVE PRESSURE 1 87 N PRODUCT -9.0 PSI 2 87 N VENT-HIRT LINE -9.0 PSI 3 87 S PRODUCT -9.0 PSI 4 87 S VENT -9.0 PSI 5 VAPOR RETURN -9.0 PSI 6 91 PRODUCT SOUTH -9.0 PSI 7 91 PRODUCT NORTH -9.0 PSI 8 91 VENT -9.0 PSI 9 91 LINE TO VENT BOX -9.0 PSI 10 DIESEL PRODUCT -9.0 PSI 11 DIESEL VENT -9.0 PSI +AAM- +AAE- I61500 OCT 10, 2023 2:13 PM TANK PRODUCT LABEL METER DATA 1 T1-Unleaded YES 2 T2-Unleaded YES 3 T3-Premium YES 4 T4-Diesel YES +AAM- +AAE- I90200 OCT 10, 2023 2:13 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE+ACM- 346336-100-C CREATED - 21.02.13.11.53 S-MODULE+ACM- 330160-106-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR ISD/APM +AAM- +AAE- I20600 OCT 10, 2023 2:13 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 TANK ALARM HISTORY TANK 1 T1-Unleaded LEAK ALARM AUG 26, 2023 10:55 PM AUG 26, 2023 10:25 PM AUG 26, 2023 9:25 PM HIGH WATER ALARM MAR 2, 2022 12:30 PM OVERFILL ALARM SEP 16, 2023 2:29 AM JUL 19, 2023 3:37 AM JUL 3, 2023 1:04 AM LOW PRODUCT ALARM SEP 30, 2023 6:13 PM SEP 28, 2023 8:11 PM SEP 8, 2023 7:12 PM PROBE OUT MAR 2, 2022 12:33 PM MAR 2, 2022 12:26 PM HIGH WATER WARNING MAR 2, 2022 12:30 PM DELIVERY NEEDED AUG 23, 2022 8:30 PM MAY 11, 2022 7:48 AM MAY 10, 2022 2:36 PM TANK 2 T2-Unleaded LEAK ALARM AUG 26, 2023 10:55 PM AUG 26, 2023 10:25 PM AUG 26, 2023 9:25 PM HIGH WATER ALARM MAR 2, 2022 12:39 PM OVERFILL ALARM AUG 20, 2023 7:06 AM JUL 19, 2023 3:35 AM JUN 7, 2023 4:16 AM LOW PRODUCT ALARM SEP 30, 2023 6:21 PM SEP 28, 2023 8:21 PM SEP 8, 2023 7:18 PM PROBE OUT MAR 2, 2022 12:42 PM MAR 2, 2022 12:27 PM HIGH WATER WARNING MAR 2, 2022 12:34 PM DELIVERY NEEDED MAY 11, 2022 8:07 AM MAY 10, 2022 3:14 PM MAY 10, 2022 11:12 AM TANK 3 T3-Premium OVERFILL ALARM AUG 27, 2023 9:45 PM JUN 29, 2023 10:11 AM OCT 24, 2022 12:52 AM LOW PRODUCT ALARM OCT 8, 2023 1:32 PM OCT 5, 2023 4:14 PM SEP 30, 2023 11:25 AM PROBE OUT MAR 2, 2022 12:40 PM MAR 2, 2022 12:29 PM HIGH WATER WARNING MAR 2, 2022 12:34 PM TANK 4 T4-Diesel LEAK ALARM AUG 26, 2023 3:55 PM AUG 26, 2023 3:25 PM AUG 3, 2023 5:46 PM HIGH WATER ALARM MAR 2, 2022 12:39 PM OVERFILL ALARM JAN 28, 2023 11:47 PM MAR 2, 2022 12:46 PM LOW PRODUCT ALARM SEP 5, 2023 11:55 AM APR 12, 2023 6:55 PM MAR 14, 2023 7:05 AM PROBE OUT MAR 2, 2022 12:46 PM MAR 2, 2022 12:28 PM HIGH WATER WARNING MAR 2, 2022 12:34 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 +AAM- +AAE- I30200 OCT 10, 2023 2:14 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 Unld T1 Int Space OCT 10, 2023 9:41 AM HIGH LIQUID ALARM OCT 10, 2023 9:40 AM LOW LIQUID ALARM OCT 10, 2023 9:35 AM SENSOR OUT ALARM 2 Unld T1 Fill Sump OCT 10, 2023 9:40 AM LOW LIQUID ALARM OCT 10, 2023 9:39 AM FUEL ALARM OCT 10, 2023 9:35 AM SENSOR OUT ALARM 3 Unld T1 STP Sump OCT 10, 2023 9:38 AM LOW LIQUID ALARM OCT 10, 2023 9:38 AM FUEL ALARM OCT 10, 2023 9:35 AM SENSOR OUT ALARM 4 Unld T2 Int Space OCT 10, 2023 9:45 AM LOW LIQUID ALARM OCT 10, 2023 9:45 AM HIGH LIQUID ALARM OCT 10, 2023 9:45 AM LOW LIQUID ALARM 5 Unld T2 Fill Sump OCT 10, 2023 9:44 AM LOW LIQUID ALARM OCT 10, 2023 9:43 AM FUEL ALARM OCT 10, 2023 9:35 AM SENSOR OUT ALARM 6 Unld T2 STP Sump OCT 10, 2023 9:43 AM LOW LIQUID ALARM OCT 10, 2023 9:42 AM FUEL ALARM OCT 10, 2023 9:35 AM SENSOR OUT ALARM 7 Prem/Dies T3/T4 Int OCT 10, 2023 9:52 AM LOW LIQUID ALARM OCT 10, 2023 9:51 AM HIGH LIQUID ALARM OCT 10, 2023 9:51 AM LOW LIQUID ALARM 8 Prem T3 Fill Sump OCT 10, 2023 9:47 AM LOW LIQUID ALARM OCT 10, 2023 9:47 AM FUEL ALARM OCT 10, 2023 9:35 AM SENSOR OUT ALARM 9 Prem T3 STP Sump OCT 10, 2023 9:46 AM LOW LIQUID ALARM OCT 10, 2023 9:46 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 10 Dies T4 Fill Sump OCT 10, 2023 9:49 AM LOW LIQUID ALARM OCT 10, 2023 9:48 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 11 Dies T4 STP Sump OCT 10, 2023 9:50 AM LOW LIQUID ALARM OCT 10, 2023 9:49 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 12 UDC FP 3-4 OCT 10, 2023 10:01 AM LOW LIQUID ALARM OCT 10, 2023 10:00 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 13 UDC FP 5-6 OCT 10, 2023 9:59 AM LOW LIQUID ALARM OCT 10, 2023 9:58 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 14 UDC FP 7-8 OCT 10, 2023 9:57 AM LOW LIQUID ALARM OCT 10, 2023 9:56 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 15 UDC FP 11-12 OCT 10, 2023 10:07 AM LOW LIQUID ALARM OCT 10, 2023 10:06 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 16 UDC FP 13-14 OCT 10, 2023 10:08 AM LOW LIQUID ALARM OCT 10, 2023 10:07 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 17 UDC FP 15-16 OCT 10, 2023 10:10 AM LOW LIQUID ALARM OCT 10, 2023 10:09 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 18 VENT BOX OCT 10, 2023 9:54 AM LOW LIQUID ALARM OCT 10, 2023 9:53 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 19 UDC FP 1-2 OCT 10, 2023 10:03 AM LOW LIQUID ALARM OCT 10, 2023 10:02 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM 20 UDC FP 9-10 OCT 10, 2023 10:05 AM LOW LIQUID ALARM OCT 10, 2023 10:04 AM FUEL ALARM OCT 10, 2023 9:36 AM SENSOR OUT ALARM +AAM- +AAE- I31600 OCT 10, 2023 2:14 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87 N PRODUCT OCT 10, 2023 10:14 AM NO VACUUM ALARM OCT 10, 2023 10:13 AM NO VACUUM ALARM OCT 10, 2023 10:13 AM HIGH LIQUID ALARM 2 87 N VENT-HIRT LINE OCT 10, 2023 10:14 AM NO VACUUM ALARM OCT 10, 2023 10:13 AM NO VACUUM ALARM OCT 10, 2023 10:13 AM HIGH LIQUID ALARM 3 87 S PRODUCT OCT 10, 2023 10:16 AM NO VACUUM ALARM OCT 10, 2023 10:16 AM HIGH LIQUID ALARM OCT 3, 2023 9:47 AM HIGH LIQUID ALARM 4 87 S VENT OCT 10, 2023 10:16 AM NO VACUUM ALARM OCT 10, 2023 10:16 AM HIGH LIQUID ALARM OCT 3, 2023 9:47 AM HIGH LIQUID ALARM 5 VAPOR RETURN OCT 10, 2023 10:16 AM NO VACUUM ALARM OCT 10, 2023 10:16 AM HIGH LIQUID ALARM OCT 3, 2023 9:47 AM HIGH LIQUID ALARM 6 91 PRODUCT SOUTH OCT 10, 2023 10:20 AM NO VACUUM ALARM OCT 10, 2023 10:19 AM HIGH LIQUID ALARM OCT 3, 2023 9:42 AM HIGH LIQUID ALARM 7 91 PRODUCT NORTH OCT 10, 2023 10:20 AM NO VACUUM ALARM OCT 10, 2023 10:19 AM HIGH LIQUID ALARM OCT 3, 2023 9:42 AM HIGH LIQUID ALARM 8 91 VENT OCT 10, 2023 10:20 AM NO VACUUM ALARM OCT 10, 2023 10:19 AM HIGH LIQUID ALARM OCT 3, 2023 9:42 AM HIGH LIQUID ALARM 9 91 LINE TO VENT BOX OCT 10, 2023 10:20 AM NO VACUUM ALARM OCT 10, 2023 10:19 AM HIGH LIQUID ALARM OCT 3, 2023 9:42 AM HIGH LIQUID ALARM 10 DIESEL PRODUCT OCT 10, 2023 10:24 AM NO VACUUM ALARM OCT 10, 2023 10:24 AM HIGH LIQUID ALARM OCT 3, 2023 9:45 AM HIGH LIQUID ALARM 11 DIESEL VENT OCT 10, 2023 10:24 AM NO VACUUM ALARM OCT 10, 2023 10:24 AM HIGH LIQUID ALARM OCT 3, 2023 9:45 AM HIGH LIQUID ALARM 12 AFM DISP 1-2 13 AFM DISP 3-4 14 AFM DISP 5-6 15 AFM DISP 7-8 16 AFM DISP 9-10 17 AFM DISP 11-12 18 VPS DISP 7-8 19 AFM DISP 13-14 20 AFM DISP 15-16 24 ATM PRESSURE SENSOR +AAM- Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry