HomeMy WebLinkAbout1.8-6873 PH 2GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE 55'48'65'59'GIACALONE 70'64'60' 54' 60'GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE ELECTRIC MATERIALS HARVEST GROVE PHASE - 2 TRACT 6873 New Residential LGI Homes, INC. Gosford Road & McCutchens Road Bakersfield PM# 35274099 11/12/2021 21-146 Project Manager: Paul Giacalone Designed By: Brian Rubio / BrianR@DryUtilityDesign.com MATERIAL LIST BY LOCATION LOCATION QUANTITY EACH/FT.MATERIAL CODE DESCRIPTION FOOTNOTE 800 1 EACH 18-0134 RISER BKT. COMBO ^ 800 3 EACH 36-0673 10' LENGTH, 3" RISER MOULD.^ 800 3 EACH 33-0306 CUTOUT, PT-44H ^ 800 3 EACH 33-2276 FUSE, POWER TYPE "E", SMU-20, 23KV, 65 AMP ^ 800 3 EACH 03-1942 CABLE TERM. #4-1/0A, 25KV ^ 800 3 EACH 30-3845 CABLE PIN TERMINAL 1/0A ^ 800 3 EACH 30-0425 FIRED WEDGE CONNECTOR ^ 800 3 EACH 29-0290 PRIMARY LEAD WIRE, 2C ^ 800 1 EACH 18-4223 CABLE GRIP, PT-7 ^ 800 1 EACH 38-2045 CABLE PROTECTOR ^ 800 2 EACH 37-3038 HIGH VOLTAGE SIGN ^ 800 10 FT AS REQ'D RISER BUS, #6 Cu WIRE ^ 801 1 EACH LABOR CONNECT SERVICE ^ 1 1 EACH 36-0673 10' LENGTH, 3" RISER MOULD. 1 2 EACH 36-0542 3" PVC BACK-UP PLATE 1 2 EACH 36-0414 RISER BEND, 4" 1 2 EACH 36-0075 REDUCER BOOT, 4" X 3" X 2" 1 45 FT 29-0073 RISER BUS, #4Cu WIRE 1 1 EACH 18-7013 GROUND ROD, 5/8" x 8' 1 2 EACH 18-7012 GROUND ROD CLAMPS 2 647 FT 29-0047 CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV 2 6 EACH 38-4202 1/0A PRIMARY CABLE END CAP 2 4 EACH 50-0117 FRONT END PACK, 4"-6" 2 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 3 6 EACH 30-5244 CONNECTOR, COMPRESSION 3 15 FT 29-0074 WIRE, #2AWG, SOLID CU 3 EACH AS REQ'D PHASE AND VOLTAGE TAG 3 EACH AS REQ'D SECTIONALIZING TAG 3 2 EACH 36-2616 PRIMARY RACKING, KIT 2 (12" ROD) 4 597 FT 29-0047 CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV 4 6 EACH 38-4202 1/0A PRIMARY CABLE END CAP 4 3 EACH 50-0117 FRONT END PACK, 4"-6" 4 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 5 6 EACH 30-5244 CONNECTOR, COMPRESSION 5 15 FT 29-0074 WIRE, #2AWG, SOLID CU 5 EACH AS REQ'D PHASE AND VOLTAGE TAG 5 EACH AS REQ'D SECTIONALIZING TAG 5 2 EACH 36-2616 PRIMARY RACKING, KIT 2 (12" ROD) PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 6 268 FT 29-0047 CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV 6 6 EACH 38-4202 1/0A PRIMARY CABLE END CAP 6 2 EACH 50-0117 FRONT END PACK, 4"-6" 6 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 6 1 EACH LABOR CONNECT CONDUIT 6 182 FT 01-6472 CONDUIT, 4" 6 1 EACH 36-0761 BEND, 4", 22 DEG, 60"R 6 1 EACH 36-0415 BEND, 4", 90 DEG, 60"R 6 1 EACH 36-0414 BEND, 4", 90 DEG, 36"R 6 1 EACH 36-0423 BELL END, 4" 6 1 EACH 36-0443 TEMPORARY CAP PLUG, 4" 7 247 FT 29-0046 CABLE, 2-1/0AL, EPR-CONC-ENCAP 25KV 7 4 EACH 38-4202 1/0A PRIMARY CABLE END CAP 7 2 EACH 50-0117 FRONT END PACK, 4"-6" 7 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 7 233 FT 01-6472 CONDUIT, 4" 7 2 EACH 36-0805 BEND, 4", 11 DEG, 60"R 7 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 7 1 EACH 36-0415 BEND, 4", 90 DEG, 60"R 7 2 EACH 36-0423 BELL END, 4" 7 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 8 1 EACH 26-1509 TX,PM,100KVA,12/21,2 WIRE,LB,DF 8 1 EACH 36-0003 BOX PAD, 50" X 52" X 18" 8 2 EACH 30-0480 ELBOW, 200A, LB 8 2 EACH 30-0481 BUSHING INSERT, LB 8 2 EACH 30-0486 INSULATED BUSHING WELL PLUG 8 3 EACH 03-1604 SEC CONN, BAR TYPE 8 15 FT 29-0074 WIRE, #2AWG, SOLID CU 8 2 EACH 18-7013 GROUND ROD, 5/8"X8' 8 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 8 1 EACH 49-5228 COMPOUND CAULKING 8 1 EACH 01-6583 PADLOCK, CORPORATION 8 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 8 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 9 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 9 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 10 138 FT 29-4371 4/0A TPX 600V CABLE 10 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 10 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 10 2 EACH 50-0118 FRONT END PACK, 2"-3" 10 124 FT 01-6471 CONDUIT, 3" 10 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 10 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 10 2 EACH 36-0421 BELL END, 3" 10 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 11 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 11 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 12 79 FT 29-4371 4/0A TPX 600V CABLE 12 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 12 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 12 2 EACH 50-0118 FRONT END PACK, 2"-3" 12 65 FT 01-6471 CONDUIT, 3" 12 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 12 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 12 2 EACH 36-0421 BELL END, 3" 12 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 13 69 FT 29-4372 350A TPX 600V CABLE 13 4 EACH 38-4200 350A SECONDARY CABLE END CAP 13 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 13 2 EACH 50-0117 FRONT END PACK, 4"-6" 13 55 FT 01-6472 CONDUIT, 4" 13 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 13 3 EACH 36-0414 BEND, 4", 90 DEG, 36"R 13 2 EACH 36-0423 BELL END, 4" 13 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 14 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 14 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 15 62 FT 29-4372 350A TPX 600V CABLE 15 4 EACH 38-4200 350A SECONDARY CABLE END CAP 15 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 15 2 EACH 50-0117 FRONT END PACK, 4"-6" 15 58 FT 01-6472 CONDUIT, 4" 15 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 15 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 15 2 EACH 36-0423 BELL END, 4" 15 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 16 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 16 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 17 102 FT 29-4372 350A TPX 600V CABLE 17 4 EACH 38-4200 350A SECONDARY CABLE END CAP 17 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 17 2 EACH 50-0117 FRONT END PACK, 4"-6" 17 88 FT 01-6472 CONDUIT, 4" 17 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 17 3 EACH 36-0414 BEND, 4", 90 DEG, 36"R 17 2 EACH 36-0423 BELL END, 4" 17 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 18 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 18 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 19 1 EACH 36-0040 PAD-MOUNTED JUNCTION BOX, STEEL-NON CORRO 19 1 EACH 36-0038 JUNCTION BOX BAD, POLYMER CONCRETE 19 10 EACH 30-0481 BUSHING INSERT, LB 19 10 EACH 30-0480 ELBOW, 200A, LB 19 2 EACH 30-0486 INSULATED BUSHING WELL PLUG 19 15 FT 29-0074 WIRE, #2AWG, SOLID CU 19 2 EACH 18-7013 GROUND ROD, 5/8"X8' 19 4 EACH 18-7012 GROUND ROD CLAMP, 5/8" 19 4 EACH 30-5244 CONNECTOR, COMPRESSION 19 4 EACH 19-0445 ANCHOR BOLT 19 2 EACH 01-8799 FAULT INDICATOR BRACKET 19 1 EACH 36-2624 FAULT INDICATOR, 450 A, 3WIRE 19 2 EACH 36-2623 FAULT INDICATOR, 450 A, 2WIRE 20 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 20 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 21 244 FT 29-0047 CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV 21 6 EACH 38-4202 1/0A PRIMARY CABLE END CAP 21 2 EACH 50-0117 FRONT END PACK, 4"-6" 21 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 21 230 FT 01-6472 CONDUIT, 4" 21 2 EACH 36-0761 BEND, 4", 22 DEG, 60"R 21 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 21 2 EACH 36-0423 BELL END, 4" 21 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 22 124 FT 29-4371 4/0A TPX 600V CABLE 22 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 22 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 22 2 EACH 50-0118 FRONT END PACK, 2"-3" 22 110 FT 01-6471 CONDUIT, 3" 22 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 22 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 22 2 EACH 36-0421 BELL END, 3" 22 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 23 329 FT 29-0046 CABLE, 2-1/0AL, EPR-CONC-ENCAP 25KV 23 4 EACH 38-4202 1/0A PRIMARY CABLE END CAP 23 2 EACH 50-0117 FRONT END PACK, 4"-6" 23 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 23 315 FT 01-6472 CONDUIT, 4" 23 2 EACH 36-0805 BEND, 4", 11 DEG, 60"R 23 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 23 1 EACH 36-0415 BEND, 4", 90 DEG, 60"R 23 2 EACH 36-0423 BELL END, 4" 23 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 24 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 24 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 25 29 FT 29-4371 4/0A TPX 600V CABLE 25 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 25 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 25 2 EACH 50-0118 FRONT END PACK, 2"-3" 25 15 FT 01-6471 CONDUIT, 3" 25 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 25 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 25 2 EACH 36-0421 BELL END, 3" 25 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 26 1 EACH 26-1508 TX,PM,50KVA,12/21,2 WIRE,LB,DF 26 1 EACH 36-0001 BOX PAD, 36" X 52" X 18" 26 4 EACH 30-0480 ELBOW, 200A, LB 26 4 EACH 30-0481 BUSHING INSERT, LB 26 3 EACH 03-1604 SEC CONN, BAR TYPE 26 15 FT 29-0074 WIRE, #2AWG, SOLID CU 26 2 EACH 18-7013 GROUND ROD, 5/8"X8' 26 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 26 1 EACH 49-5228 COMPOUND CAULKING 26 1 EACH 01-6583 PADLOCK, CORPORATION 26 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 26 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 26 2 EACH 36-2623 FAULT INDICATOR, 450 A, 2WIRE 27 114 FT 29-4371 4/0A TPX 600V CABLE 27 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 27 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 27 2 EACH 50-0118 FRONT END PACK, 2"-3" 27 100 FT 01-6471 CONDUIT, 3" 27 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 27 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 27 2 EACH 36-0421 BELL END, 3" 27 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 28 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 28 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 29 232 FT 29-0046 CABLE, 2-1/0AL, EPR-CONC-ENCAP 25KV 29 4 EACH 38-4202 1/0A PRIMARY CABLE END CAP 29 2 EACH 50-0117 FRONT END PACK, 4"-6" 29 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 29 218 FT 01-6472 CONDUIT, 4" 29 2 EACH 36-0805 BEND, 4", 11 DEG, 60"R 29 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 29 1 EACH 36-0415 BEND, 4", 90 DEG, 60"R 29 2 EACH 36-0423 BELL END, 4" 29 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 30 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 30 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 31 95 FT 29-4371 4/0A TPX 600V CABLE 31 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 31 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 31 2 EACH 50-0118 FRONT END PACK, 2"-3" 31 81 FT 01-6471 CONDUIT, 3" 31 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 31 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 31 1 EACH 36-0328 BEND, 3", 90 DEG, 36"R 31 2 EACH 36-0421 BELL END, 3" 31 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 32 1 EACH 26-1508 TX,PM,50KVA,12/21,2 WIRE,LB,DF 32 1 EACH 36-0001 BOX PAD, 36" X 52" X 18" 32 4 EACH 30-0480 ELBOW, 200A, LB 32 4 EACH 30-0481 BUSHING INSERT, LB 32 3 EACH 03-1604 SEC CONN, BAR TYPE 32 15 FT 29-0074 WIRE, #2AWG, SOLID CU 32 2 EACH 18-7013 GROUND ROD, 5/8"X8' 32 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 32 1 EACH 49-5228 COMPOUND CAULKING 32 1 EACH 01-6583 PADLOCK, CORPORATION 32 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 32 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 32 2 EACH 36-2623 FAULT INDICATOR, 450 A, 2WIRE 33 75 FT 29-4371 4/0A TPX 600V CABLE 33 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 33 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 33 2 EACH 50-0118 FRONT END PACK, 2"-3" 33 61 FT 01-6471 CONDUIT, 3" 33 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 33 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 33 2 EACH 36-0421 BELL END, 3" 33 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 34 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 34 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 35 74 FT 29-4371 4/0A TPX 600V CABLE 35 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 35 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 35 2 EACH 50-0118 FRONT END PACK, 2"-3" 35 60 FT 01-6471 CONDUIT, 3" 35 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 35 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 35 2 EACH 36-0421 BELL END, 3" 35 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 36 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 36 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 37 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 37 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 38 346 FT 29-0046 CABLE, 2-1/0AL, EPR-CONC-ENCAP 25KV 38 4 EACH 38-4202 1/0A PRIMARY CABLE END CAP 38 2 EACH 50-0117 FRONT END PACK, 4"-6" 38 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 38 332 FT 01-6472 CONDUIT, 4" 38 2 EACH 36-0761 BEND, 4", 22 DEG, 60"R 38 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 38 2 EACH 36-0423 BELL END, 4" 38 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 39 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 39 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 40 66 FT 29-4371 4/0A TPX 600V CABLE 40 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 40 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 40 2 EACH 50-0118 FRONT END PACK, 2"-3" 40 52 FT 01-6471 CONDUIT, 3" 40 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 40 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 40 2 EACH 36-0421 BELL END, 3" 40 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 41 1 EACH 26-1533 TX,PM,100KVA,12/21KV, 3 WIRE, DF-LB 41 1 EACH 36-0003 BOX PAD, 50" X 52" X 18" 41 6 EACH 30-0480 ELBOW, 200A, LB 41 6 EACH 30-0481 BUSHING INSERT, LB 41 3 EACH 03-1604 SEC CONN, BAR TYPE 41 15 FT 29-0074 WIRE, #2AWG, SOLID CU 41 2 EACH 18-7013 GROUND ROD, 5/8"X8' 41 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 41 1 EACH 49-5228 COMPOUND CAULKING 41 1 EACH 01-6583 PADLOCK, CORPORATION 41 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 41 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 41 1 EACH 36-2624 FAULT INDICATOR, 450A, 3-WIRE 42 74 FT 29-4372 350A TPX 600V CABLE 42 4 EACH 38-4200 350A SECONDARY CABLE END CAP 42 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 42 2 EACH 50-0117 FRONT END PACK, 4"-6" 42 60 FT 01-6472 CONDUIT, 4" 42 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 42 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 42 2 EACH 36-0423 BELL END, 4" 42 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 43 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 43 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 44 134 FT 29-4372 350A TPX 600V CABLE 44 4 EACH 38-4200 350A SECONDARY CABLE END CAP 44 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 44 2 EACH 50-0117 FRONT END PACK, 4"-6" 44 120 FT 01-6472 CONDUIT, 4" 44 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 44 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 44 2 EACH 36-0423 BELL END, 4" 44 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 45 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 45 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 46 374 FT 29-0047 CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV 46 6 EACH 38-4202 1/0A PRIMARY CABLE END CAP 46 2 EACH 50-0117 FRONT END PACK, 4"-6" 46 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 46 360 FT 01-6472 CONDUIT, 4" 46 2 EACH 36-0761 BEND, 4", 22 DEG, 60"R 46 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 46 2 EACH 36-0423 BELL END, 4" 46 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 47 152 FT 29-4371 4/0A TPX 600V CABLE 47 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 47 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 47 2 EACH 50-0118 FRONT END PACK, 2"-3" 47 138 FT 01-6471 CONDUIT, 3" 47 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 47 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 47 2 EACH 36-0421 BELL END, 3" 47 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 48 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 48 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 49 64 FT 29-4372 350A TPX 600V CABLE 49 4 EACH 38-4200 350A SECONDARY CABLE END CAP 49 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 49 2 EACH 50-0117 FRONT END PACK, 4"-6" 49 50 FT 01-6472 CONDUIT, 4" 49 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 49 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 49 2 EACH 36-0423 BELL END, 4" 49 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 50 54 FT 29-4371 4/0A TPX 600V CABLE 50 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 50 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 50 2 EACH 50-0118 FRONT END PACK, 2"-3" 50 40 FT 01-6471 CONDUIT, 3" 50 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 50 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 50 2 EACH 36-0421 BELL END, 3" 50 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 51 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 51 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 52 1 EACH 26-1508 TX,PM,50KVA,12/21,2 WIRE,LB,DF 52 1 EACH 36-0001 BOX PAD, 36" X 52" X 18" 52 2 EACH 30-0480 ELBOW, 200A, LB 52 2 EACH 30-0481 BUSHING INSERT, LB 52 2 EACH 30-0486 INSULATED BUSHING WELL PLUG 52 3 EACH 03-1604 SEC CONN, BAR TYPE 52 15 FT 29-0074 WIRE, #2AWG, SOLID CU 52 2 EACH 18-7013 GROUND ROD, 5/8"X8' 52 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 52 1 EACH 49-5228 COMPOUND CAULKING 52 1 EACH 01-6583 PADLOCK, CORPORATION 52 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 52 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 53 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 53 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 54 74 FT 29-4371 4/0A TPX 600V CABLE 54 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 54 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 54 2 EACH 50-0118 FRONT END PACK, 2"-3" 54 60 FT 01-6471 CONDUIT, 3" 54 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 54 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 54 2 EACH 36-0421 BELL END, 3" 54 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 55 1 EACH 26-1533 TX,PM,100KVA,12/21KV, 3 WIRE, DF-LB 55 1 EACH 36-0003 BOX PAD, 50" X 52" X 18" 55 6 EACH 30-0480 ELBOW, 200A, LB 55 6 EACH 30-0481 BUSHING INSERT, LB 55 3 EACH 03-1604 SEC CONN, BAR TYPE 55 15 FT 29-0074 WIRE, #2AWG, SOLID CU 55 2 EACH 18-7013 GROUND ROD, 5/8"X8' 55 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 55 1 EACH 49-5228 COMPOUND CAULKING 55 1 EACH 01-6583 PADLOCK, CORPORATION 55 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 55 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 55 1 EACH 36-2624 FAULT INDICATOR, 450A, 3-WIRE PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 56 105 FT 29-0372 750A TPX 600V CABLE 56 4 EACH 38-4201 750A SECONDARY CABLE END CAP 56 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 56 2 EACH 50-0117 FRONT END PACK, 4"-6" 56 90 FT 01-6472 CONDUIT, 4" 56 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 56 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 56 2 EACH 36-0423 BELL END, 4" 56 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 57 1 EACH 04-0942 24" X 36" X 26" SEC BOX, IVT 57 1 EACH 02-6694 6-WAY SEC. BUS, (4) #6-350A, (2) 4/0A-1000A 58 64 FT 29-0372 750A TPX 600V CABLE 58 4 EACH 38-4201 750A SECONDARY CABLE END CAP 58 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 58 2 EACH 50-0117 FRONT END PACK, 4"-6" 58 49 FT 01-6472 CONDUIT, 4" 58 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 58 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 58 2 EACH 36-0423 BELL END, 4" 58 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 59 1 EACH 04-0942 24" X 36" X 26" SEC BOX, IVT 59 1 EACH 02-6694 6-WAY SEC. BUS, (4) #6-350A, (2) 4/0A-1000A 60 151 FT 29-4372 350A TPX 600V CABLE 60 4 EACH 38-4200 350A SECONDARY CABLE END CAP 60 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 60 2 EACH 50-0117 FRONT END PACK, 4"-6" 60 136 FT 01-6472 CONDUIT, 4" 60 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 60 3 EACH 36-0414 BEND, 4", 90 DEG, 36"R 60 2 EACH 36-0423 BELL END, 4" 60 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 61 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 61 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 62 133 FT 29-4371 4/0A TPX 600V CABLE 62 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 62 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 62 2 EACH 50-0118 FRONT END PACK, 2"-3" 62 119 FT 01-6471 CONDUIT, 3" 62 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 62 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 62 2 EACH 36-0421 BELL END, 3" 62 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 63 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 63 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 64 69 FT 29-4371 4/0A TPX 600V CABLE 64 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 64 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 64 2 EACH 50-0118 FRONT END PACK, 2"-3" 64 55 FT 01-6471 CONDUIT, 3" 64 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 64 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 64 2 EACH 36-0421 BELL END, 3" 64 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 65 1 EACH 26-1533 TX,PM,100KVA,12/21KV, 3 WIRE, DF-LB 65 1 EACH 36-0003 BOX PAD, 50" X 52" X 18" 65 5 EACH 30-0480 ELBOW, 200A, LB 65 5 EACH 30-0481 BUSHING INSERT, LB 65 1 EACH 30-0486 INSULATED BUSHING WELL PLUG 65 3 EACH 03-1604 SEC CONN, BAR TYPE 65 15 FT 29-0074 WIRE, #2AWG, SOLID CU 65 2 EACH 18-7013 GROUND ROD, 5/8"X8' 65 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 65 1 EACH 49-5228 COMPOUND CAULKING 65 1 EACH 01-6583 PADLOCK, CORPORATION 65 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 65 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 65 2 EACH 36-2623 FAULT INDICATOR, 450 A, 2WIRE 66 69 FT 29-4372 350A TPX 600V CABLE 66 4 EACH 38-4200 350A SECONDARY CABLE END CAP 66 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 66 2 EACH 50-0117 FRONT END PACK, 4"-6" 66 55 FT 01-6472 CONDUIT, 4" 66 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 66 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 66 2 EACH 36-0423 BELL END, 4" 66 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 67 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 67 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 68 124 FT 29-4372 350A TPX 600V CABLE 68 4 EACH 38-4200 350A SECONDARY CABLE END CAP 68 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 68 2 EACH 50-0117 FRONT END PACK, 4"-6" 68 110 FT 01-6472 CONDUIT, 4" 68 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 68 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 68 2 EACH 36-0423 BELL END, 4" 68 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 69 527 FT 29-0047 CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV 69 6 EACH 38-4202 1/0A PRIMARY CABLE END CAP 69 3 EACH 50-0117 FRONT END PACK, 4"-6" 69 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 69 513 FT 01-6472 CONDUIT, 4" 69 2 EACH 36-0805 BEND, 4", 11 DEG, 60"R 69 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 69 1 EACH 36-0415 BEND, 4", 90 DEG, 60"R 69 2 EACH 36-0423 BELL END, 4" 69 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 70 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 70 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 71 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 71 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 71 254 FT 29-4370 1/0A TPX 600V CABLE 1630 71 4 EACH 38-4198 1/0A SECONDARY CABLE END CAP 1630 71 2 EACH 38-4197 #2A SECONDARY CABLE END CAP 1630 71 2 EACH 50-0118 FRONT END PACK, 2"-3"1630 71 240 FT 01-6471 CONDUIT, 3"1632 71 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 1632 71 1 EACH 36-0405 BEND, 3", 90 DEG, 24"R 1632 71 1 EACH 36-0328 BEND, 3", 90 DEG, 36"R 1632 71 1 EACH 36-0421 BELL END, 3"1632 71 2 EACH 36-0441 TEMPORARY CAP PLUG, 3"1632 71 1 EACH NO CODE METER, CL.200, 100 AMS, 120/240 1PH.^ 72 695 FT 29-0046 CABLE, 2-1/0AL, EPR-CONC-ENCAP 25KV 72 4 EACH 38-4202 1/0A PRIMARY CABLE END CAP 72 4 EACH 50-0117 FRONT END PACK, 4"-6" 72 1 EACH 50-0031 LUBRICANT, CABLE PULLING 2.5 GAL. 72 681 FT 01-6472 CONDUIT, 4" 72 2 EACH 36-0805 BEND, 4", 11 DEG, 60"R 72 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 72 1 EACH 36-0415 BEND, 4", 90 DEG, 60"R 72 2 EACH 36-0423 BELL END, 4" 72 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 73 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 73 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 74 156 FT 29-4372 350A TPX 600V CABLE 74 4 EACH 38-4200 350A SECONDARY CABLE END CAP 74 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 74 2 EACH 50-0117 FRONT END PACK, 4"-6" 74 142 FT 01-6472 CONDUIT, 4" 74 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 74 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 74 2 EACH 36-0423 BELL END, 4" 74 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 75 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 75 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 76 156 FT 29-4372 350A TPX 600V CABLE 76 4 EACH 38-4200 350A SECONDARY CABLE END CAP 76 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 76 2 EACH 50-0117 FRONT END PACK, 4"-6" 76 142 FT 01-6472 CONDUIT, 4" 76 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 76 3 EACH 36-0414 BEND, 4", 90 DEG, 36"R 76 2 EACH 36-0423 BELL END, 4" 76 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 77 1 EACH 04-0937 17" X 30" X 26" SEC BOX, IVT 77 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A 78 69 FT 29-4372 350A TPX 600V CABLE 78 4 EACH 38-4200 350A SECONDARY CABLE END CAP 78 2 EACH 38-4199 4/0A SECONDARY CABLE END CAP 78 2 EACH 50-0117 FRONT END PACK, 4"-6" 78 55 FT 01-6472 CONDUIT, 4" 78 2 EACH 36-0760 BEND, 4", 22 DEG, 36"R 78 2 EACH 36-0414 BEND, 4", 90 DEG, 36"R 78 2 EACH 36-0423 BELL END, 4" 78 2 EACH 36-0443 TEMPORARY CAP PLUG, 4" 79 1 EACH 26-1533 TX,PM,100KVA,12/21KV, 3 WIRE, DF-LB 79 1 EACH 36-0003 BOX PAD, 50" X 52" X 18" 79 2 EACH 30-0480 ELBOW, 200A, LB 79 2 EACH 30-0481 BUSHING INSERT, LB 79 2 EACH 30-0486 INSULATED BUSHING WELL PLUG 79 3 EACH 03-1604 SEC CONN, BAR TYPE 79 15 FT 29-0074 WIRE, #2AWG, SOLID CU 79 2 EACH 18-7013 GROUND ROD, 5/8"X8' 79 2 EACH 18-7012 GROUND ROD CLAMP, 5/8" 79 1 EACH 49-5228 COMPOUND CAULKING 79 1 EACH 01-6583 PADLOCK, CORPORATION 79 2 EACH 19-2874 BOLT, 1/2"-13 X 1 1/2" 79 2 EACH 19-5286 WASHER, 2 1/4" SQUARE 80 69 FT 29-4371 4/0A TPX 600V CABLE 80 4 EACH 38-4199 4/0A SECONDARY CABLE END CAP 80 2 EACH 38-4198 1/0A SECONDARY CABLE END CAP 80 2 EACH 50-0118 FRONT END PACK, 2"-3" 80 55 FT 01-6471 CONDUIT, 3" 80 2 EACH 36-0800 BEND, 3", 22 DEG, 36"R 80 2 EACH 36-0405 BEND, 3", 90 DEG, 24"R 80 2 EACH 36-0421 BELL END, 3" 80 2 EACH 36-0441 TEMPORARY CAP PLUG, 3" 81 1 EACH 04-0936 17" X 30" X 18" SEC BOX, IVT 81 3 EACH 30-0552 6-WAY SEC. BUS, #6-350A PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch 998 3592 FT 01-6471 CONDUIT, 3"1602 998 81 EACH 36-0405 BEND, 3", 90 DEG, 24"R 1602 998 30 EACH 36-0800 BEND, 3", 22.5 DEG, 36"R 1602 998 30 EACH 36-0328 BEND, 3", 90 DEG, 36"R 1602 998 81 EACH 36-0441 TEMPORARY CAP, 3"1602 998 81 EACH 36-0421 BELL END, 3"1602 999 6940 FT 29-4371 SERVICE CABLE, 4/0A TPX 1600 999 328 EACH 38-4199 4/0A CABLE END CAP 1600 999 164 EACH 38-4198 1/0A CABLE END CAP 1600 999 82 EACH 50-0118 FRONT END PACK, 2"-3"1600 999 2121 FT 01-6471 CONDUIT, 3"1603 999 82 EACH 36-0800 BEND, 3", 22.5 DEG, 36"R 1603 999 82 EACH 36-0441 TEMPORARY CAP, 3"1603 999 82 EACH NO CODE METER, CL.200, 200 AMS, 120/240 1PH.^ PM# 35274099 11/12/21 GDSI "^" PG Ins Mat "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch"1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat"1602" Ap Ins Non Res Sv Dct Frnch APPLICANT INSTALL MATERIAL SUMMARY MATERIAL CODE FOOTNOTE DESCRIPTION EACH/FT.Total 01-6471 (blank)CONDUIT, 3"FT 1135 1602 CONDUIT, 3"FT 3592 1603 CONDUIT, 3"FT 2121 1632 CONDUIT, 3"FT 240 01-6472 (blank)CONDUIT, 4"FT 4274 01-6583 (blank)PADLOCK, CORPORATION EACH 8 01-8799 (blank)FAULT INDICATOR BRACKET EACH 2 02-6694 (blank)6-WAY SEC. BUS, (4) #6-350A, (2) 4/0A-1000A EACH 2 03-1604 (blank)SEC CONN, BAR TYPE EACH 24 04-0936 (blank)17" X 30" X 18" SEC BOX, IVT EACH 15 04-0937 (blank)17" X 30" X 26" SEC BOX, IVT EACH 1204-0942 (blank)24" X 36" X 26" SEC BOX, IVT EACH 2 18-7012 (blank)GROUND ROD CLAMPS EACH 2 GROUND ROD CLAMP, 5/8"EACH 20 18-7013 (blank)GROUND ROD, 5/8" x 8'EACH 1 GROUND ROD, 5/8"X8'EACH 18 19-0445 (blank)ANCHOR BOLT EACH 4 19-2874 (blank)BOLT, 1/2"-13 X 1 1/2"EACH 16 19-5286 (blank)WASHER, 2 1/4" SQUARE EACH 16 26-1508 (blank)TX,PM,50KVA,12/21,2 WIRE,LB,DF EACH 3 26-1509 (blank)TX,PM,100KVA,12/21,2 WIRE,LB,DF EACH 1 26-1533 (blank)TX,PM,100KVA,12/21KV, 3 WIRE, DF-LB EACH 4 29-0046 (blank)CABLE, 2-1/0AL, EPR-CONC-ENCAP 25KV FT 1849 29-0047 (blank)CABLE, 3-1/0AL, EPR-CONC-ENCAP 25KV FT 2657 29-0073 (blank)RISER BUS, #4Cu WIRE FT 45 29-0074 (blank)WIRE, #2AWG, SOLID CU FT 165 29-0372 (blank)750A TPX 600V CABLE FT 169 29-4370 1630 1/0A TPX 600V CABLE FT 254 29-4371 (blank)4/0A TPX 600V CABLE FT 1345 1600 SERVICE CABLE, 4/0A TPX FT 6940 29-4372 (blank)350A TPX 600V CABLE FT 1230 30-0480 (blank)ELBOW, 200A, LB EACH 41 30-0481 (blank)BUSHING INSERT, LB EACH 41 30-0486 (blank)INSULATED BUSHING WELL PLUG EACH 9 30-0552 (blank)6-WAY SEC. BUS, #6-350A EACH 81 30-5244 (blank)CONNECTOR, COMPRESSION EACH 1636-0001 (blank)BOX PAD, 36" X 52" X 18"EACH 3 36-0003 (blank)BOX PAD, 50" X 52" X 18"EACH 5 36-0038 (blank)JUNCTION BOX BAD, POLYMER CONCRETE EACH 1 36-0040 (blank)PAD-MOUNTED JUNCTION BOX, STEEL-NON COREACH 1 36-0075 (blank)REDUCER BOOT, 4" X 3" X 2"EACH 2 PM# 35274099 11/12/21GDSI 16 "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch "1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat "1602" Ap Ins Non Res Sv Dct Frnch 36-0328 (blank)BEND, 3", 90 DEG, 36"R EACH 1 1602 BEND, 3", 90 DEG, 36"R EACH 30 1632 BEND, 3", 90 DEG, 36"R EACH 1 36-0405 (blank)BEND, 3", 90 DEG, 24"R EACH 30 1602 BEND, 3", 90 DEG, 24"R EACH 81 1632 BEND, 3", 90 DEG, 24"R EACH 1 36-0414 (blank)BEND, 4", 90 DEG, 36"R EACH 49 RISER BEND, 4"EACH 236-0415 (blank)BEND, 4", 90 DEG, 60"R EACH 6 36-0421 (blank)BELL END, 3" EACH 30 1602 BELL END, 3"EACH 81 1632 BELL END, 3" EACH 1 36-0423 (blank)BELL END, 4"EACH 45 36-0441 (blank)TEMPORARY CAP PLUG, 3"EACH 30 1602 TEMPORARY CAP, 3"EACH 81 1603 TEMPORARY CAP, 3"EACH 82 1632 TEMPORARY CAP PLUG, 3"EACH 2 36-0443 (blank)TEMPORARY CAP PLUG, 4"EACH 45 36-0542 (blank)3" PVC BACK-UP PLATE EACH 2 36-0673 (blank)10' LENGTH, 3" RISER MOULD.EACH 1 36-0760 (blank)BEND, 4", 22 DEG, 36"R EACH 28 36-0761 (blank)BEND, 4", 22 DEG, 60"R EACH 7 36-0800 (blank)BEND, 3", 22 DEG, 36"R EACH 30 1602 BEND, 3", 22.5 DEG, 36"R EACH 30 1603 BEND, 3", 22.5 DEG, 36"R EACH 82 1632 BEND, 3", 22 DEG, 36"R EACH 2 36-0805 (blank)BEND, 4", 11 DEG, 60"R EACH 10 36-2616 (blank)PRIMARY RACKING, KIT 2 (12" ROD)EACH 4 36-2623 (blank)FAULT INDICATOR, 450 A, 2WIRE EACH 8 36-2624 (blank)FAULT INDICATOR, 450 A, 3WIRE EACH 1 FAULT INDICATOR, 450A, 3-WIRE EACH 2 38-4197 1630 #2A SECONDARY CABLE END CAP EACH 2 38-4198 (blank)1/0A SECONDARY CABLE END CAP EACH 3016001/0A CABLE END CAP EACH 164 1630 1/0A SECONDARY CABLE END CAP EACH 4 38-4199 (blank)4/0A SECONDARY CABLE END CAP EACH 88 1600 4/0A CABLE END CAP EACH 328 38-4200 (blank)350A SECONDARY CABLE END CAP EACH 48 38-4201 (blank)750A SECONDARY CABLE END CAP EACH 8 38-4202 (blank)1/0A PRIMARY CABLE END CAP EACH 56 49-5228 (blank)COMPOUND CAULKING EACH 8 50-0031 (blank)LUBRICANT, CABLE PULLING 2.5 GAL.EACH 11 50-0117 (blank)FRONT END PACK, 4"-6"EACH 56 PM# 35274099 11/12/21GDSI 17 "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch "1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat "1602" Ap Ins Non Res Sv Dct Frnch 50-0118 (blank)FRONT END PACK, 2"-3"EACH 30 1600 FRONT END PACK, 2"-3"EACH 82 1630 FRONT END PACK, 2"-3"EACH 2 AS REQ'D (blank)PHASE AND VOLTAGE TAG EACH SECTIONALIZING TAG EACH LABOR (blank)CONNECT CONDUIT EACH 1 PM# 35274099 11/12/21GDSI 18 "blank" Ap Ins Mat "1600" Ap Ins Sv Mat"1602" Ap Ins Sv Dct Frnch "1603" Ap Ins Sv Dt P/P"1630" Ap Ins Npn Res Sv Mat "1602" Ap Ins Non Res Sv Dct Frnch PG&E INSTALL MATERIAL SUMMARY MATERIAL CODE FOOTNOTE DESCRIPTION EACH/FT.Total 03-1942 ^CABLE TERM. #4-1/0A, 25KV EACH 3 18-0134 ^RISER BKT. COMBO EACH 1 18-4223 ^CABLE GRIP, PT-7 EACH 1 29-0290 ^PRIMARY LEAD WIRE, 2C EACH 3 30-0425 ^FIRED WEDGE CONNECTOR EACH 3 30-3845 ^CABLE PIN TERMINAL 1/0A EACH 3 33-0306 ^CUTOUT, PT-44H EACH 3 33-2276 ^FUSE, POWER TYPE "E", SMU-20, 23KV, 65 AMPEACH 3 36-0673 ^10' LENGTH, 3" RISER MOULD.EACH 3 37-3038 ^HIGH VOLTAGE SIGN EACH 2 38-2045 ^CABLE PROTECTOR EACH 1 LABOR ^CONNECT SERVICE EACH 1 NO CODE ^METER, CL.200, 200 AMS, 120/240 1PH.EACH 82 METER, CL.200, 100 AMS, 120/240 1PH.EACH 1 PM# 3527409911/12/21 GDSI 19 "^" PG Inst Matl PACIFIC GAS & ELECTRIC COMPANYCIRCUIT MAP CHANGE SHEET Date ILIS Event No.GIS Tag No. Control Center/AOR Substation & Curcuit Number STOCKDALE 2112 Prepare By Engineering Approved By BJ137-N13 & N14 Job Number Purpose of Work NEW BUSINESS MAT Location McCUTCHEN ROAD & GOSFORD ROAD Town Loc.Location 800 E/S OF GOSFORD RD., 32' N/O McCUTHEN RD. 8 N/S OF AVACADO LN., 127' E/O STRAWBERRY LN. 41 E/S OF STRAWBERRY LN., 78' N/O CRANBERRY LN. 55 E/S OF STRAWBERRY LN., 218' S/O GOOSEBERRY AVE. 65 N/S OF GOOSEBERRY AVE., 265' E/O STRAWBERRY LN. 79 E/S OF CHERIMOYA., 127' S/O GOOSEBERRY AVE. 26 N/S OF CRANBERRY WY., 147' E/O STRAWBERRY LN. 32 E/S OF RASBERRY AVE., 48' N/O CRANBERRY WY. 52 E/S OF RASBERRY AVE., 127' N/O BANANA CLUSTER AVE. 19 E/S OF STRAWBERRY LN., 122' N/O AVACADO LN. SEE KEY SKETCH DateDate DateDate BAKERSFIELD BAKERSFIELD BAKERSFIELD J-_____BAKERSFIELD T-15 T-16 T-17 T-18 BAKERSFIELD BAKERSFIELD 11/12/2021 New Equip. No.Serial No.Manufacture Date Manuf. Map No. BAKERSFIELD B. RUBIO 35274099 Town BAKERSFIELD BAKERSFIELD C/O-_____ T-11 Recorded at Control Center byWork competed by BAKERSFIELD BAKERSFIELD T-12 T-13 T-14 Mapped by Forward this completed form to Forman must immediatley report any completed work. For partially completed work, circle the portion that was completed. Include the date & show "completed." VOLTAGE & FLICKER DROP CALCULATIONS LOADING CRITERIA:CLIMATE ZONE R WITH 4 TON A/C PM# 35274099 NEW SERVICE INFO:1,917 AVG. SQ.FT, 200 AMS JOB# 21-146 4/0A TPX SVC IN 3" CONDUIT T-11 LOTS 48/49 LOT 58 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 11 74 0.02392 1.77 100 KVA PM TX 0.53 1.2 0.64 350A TPX SEC 8 58 0.258 69 1.03 350A TPX SEC 0.0062 69 1.2 0.51 350A TPX SEC 4 34 0.258 62 0.54 350A TPX SEC 0.0062 62 1.2 0.46 350A TPX SEC 2 21 0.258 102 0.55 350A TPX SEC 0.0062 102 1.2 0.76 4/0A TPX SVC 1 13.3 0.381 99 0.50 4/0A TPX SVC 0.0091 99 1.2 1.08 TOTAL =4.4 VOLTS TOTAL 3.5 VOLTS LOT 52 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 11 74 0.02392 1.77 100 KVA PM TX 0.53 1.2 0.64 4/0A TPX SEC 3 27 0.381 79 0.81 4/0A TPX SEC 0.0091 79 1.2 0.86 4/0A TPX SEC 1 13.3 0.381 138 0.70 4/0A TPX SEC 0.0091 138 1.2 1.51 4/0A TPX SVC 1 13.3 0.381 45 0.23 4/0A TPX SVC 0.0091 45 1.2 0.49 TOTAL =3.5 VOLTS TOTAL 3.5 VOLTS T-12 LOTS 24/25 LOT 66 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 13 85 0.02392 2.03 100 KVA PM TX 0.53 1.2 0.64 350A TPX SEC 8 58 0.258 74 1.11 350A TPX SEC 0.0062 74 1.2 0.55 350A TPX SEC 4 34 0.258 134 1.18 350A TPX SEC 0.0062 134 1.2 1.00 4/0A TPX SVC 1 13.3 0.381 111 0.56 4/0A TPX SVC 0.0091 111 1.2 1.21TOTAL =4.9 VOLTS TOTAL 3.4 VOLTS LOT 60 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 13 85 0.02392 2.03 100 KVA PM TX 0.53 1.2 0.64 4/0A TPX SEC 5 39 0.381 66 0.98 4/0A TPX SEC 0.0091 66 1.2 0.72 4/0A TPX SEC 2 21 0.381 124 0.99 4/0A TPX SEC 0.0091 124 1.2 1.35 4/0A TPX SVC 1 13.3 0.381 99 0.50 4/0A TPX SVC 0.0091 99 1.2 1.08 TOTAL =4.5 VOLTS TOTAL 3.8 VOLTS PM# 3527409911/12/21GDSI 1 VOLTAGE & FLICKER DROP CALCULATIONS LOADING CRITERIA:CLIMATE ZONE R WITH 4 TON A/C PM# 35274099 NEW SERVICE INFO:1,917 AVG. SQ.FT, 200 AMS JOB# 21-146 4/0A TPX SVC IN 3" CONDUIT T-13 LOTS 18/19 + (1) 100A POWER SUPPLY = 2KVA LOT 1 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 12 + 1 80 0.02392 1.91 100 KVA PM TX 0.53 1.2 0.64 750A TPX SEC 8 + 1 60 0.1508 105 0.95 750A TPX SEC 0.0036 105 1.2 0.45 750A TPX SEC 5 + 1 41 0.1508 64 0.40 750A TPX SEC 0.0036 64 1.2 0.28 350A TPX SEC 3 + 1 29 0.258 151 1.13 350A TPX SEC 0.0062 151 1.2 1.12 4/0A TPX SVC 1 13.3 0.381 100 0.51 4/0A TPX SVC 0.0091 100 1.2 1.09TOTAL =4.9 VOLTS TOTAL 3.6 VOLTS LOT 68 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 12 + 1 80 0.02392 1.91 100 KVA PM TX 0.53 1.2 0.64 4/0A TPX SEC 4 34 0.381 74 0.96 4/0A TPX SEC 0.0091 74 1.2 0.81 4/0A TPX SVC 1 13.3 0.381 122 0.62 4/0A TPX SVC 0.0091 122 1.2 1.33 TOTAL =3.5 VOLTS TOTAL 2.8 VOLTS 100A CATV VOLTAGE DROP # CUSTOMERS KVA K DISTANCE TOTAL 100 KVA PM TX 12 + 1 80 0.02392 1.91 750A TPX SEC 8 + 1 60 0.1508 105 0.95 750A TPX SEC 5 + 1 41 0.1508 64 0.40 350A TPX SEC 3 + 1 29 0.258 151 1.13 4/0A TPX SVC 1 2 0.701 254 0.36 TOTAL =4.7 VOLTS T-14 LOTS 7/8 LOT 17 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 14 90 0.02392 2.15 100 KVA PM TX 0.53 1.2 0.64 350A TPX SEC 8 58 0.258 69 1.03 350A TPX SEC 0.0062 69 1.2 0.51 350A TPX SEC 4 34 0.258 124 1.09 350A TPX SEC 0.0062 124 1.2 0.92 4/0A TPX SVC 1 13.3 0.381 105 0.53 4/0A TPX SVC 0.0091 105 1.2 1.15 TOTAL =4.8 VOLTS TOTAL 3.2 VOLTS LOT 11 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 14 90 0.02392 2.15 100 KVA PM TX 0.53 1.2 0.64 4/0A TPX SEC 6 46 0.381 69 1.21 4/0A TPX SEC 0.0091 69 1.2 0.75 4/0A TPX SEC 2 21 0.381 133 1.06 4/0A TPX SEC 0.0091 133 1.2 1.45 4/0A TPX SVC 1 13.3 0.381 58 0.29 4/0A TPX SVC 0.0091 58 1.2 0.63 TOTAL =4.7 VOLTS TOTAL 3.5 VOLTS PM# 3527409911/12/21GDSI 2 VOLTAGE & FLICKER DROP CALCULATIONS LOADING CRITERIA:CLIMATE ZONE R WITH 4 TON A/C PM# 35274099 NEW SERVICE INFO:1,917 AVG. SQ.FT, 200 AMS JOB# 21-146 4/0A TPX SVC IN 3" CONDUIT T-15 LOTS 74/75 LOT 81 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 10 74 0.02392 1.77 100 KVA PM TX 0.53 1.2 0.64 350A TPX SEC 8 58 0.258 69 1.03 350A TPX SEC 0.0062 69 1.2 0.51 350A TPX SEC 4 34 0.258 156 1.37 350A TPX SEC 0.0062 156 1.2 1.16 350A TPX SEC 2 21 0.258 100 0.54 350A TPX SEC 0.0062 100 1.2 0.74 4/0A TPX SVC 1 13.3 0.381 47 0.24 4/0A TPX SVC 0.0091 47 1.2 0.51TOTAL =5.0 VOLTS TOTAL 3.6 VOLTS LOT 76 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 10 74 0.02392 1.77 100 KVA PM TX 0.53 1.2 0.64 4/0A TPX SEC 2 21 0.381 69 0.55 4/0A TPX SEC 0.0091 69 1.2 0.75 4/0A TPX SVC 1 13.3 0.381 47 0.24 4/0A TPX SVC 0.0091 47 1.2 0.51 TOTAL =2.6 VOLTS TOTAL 1.9 VOLTS T-16 LOTS 25/26 LOT 41 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 50 KVA PM TX 7 51 0.04687 2.39 50 KVA PM TX 1 1.2 1.20 4/0A TPX SEC 4 34 0.381 114 1.48 4/0A TPX SEC 0.0091 114 1.2 1.24 4/0A TPX SEC 2 21 0.381 95 0.76 4/0A TPX SEC 0.0091 95 1.2 1.04 4/0A TPX SVC 1 13.3 0.381 47 0.24 4/0A TPX SVC 0.0091 47 1.2 0.51TOTAL =4.9 VOLTS TOTAL 4.0 VOLTS LOT 46 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 50 KVA PM TX 7 51 0.04687 2.39 50 KVA PM TX 1 1.2 1.20 4/0A TPX SEC 3 27 0.381 29 0.30 4/0A TPX SEC 0.0091 29 1.2 0.32 4/0A TPX SVC 1 13.3 0.381 157 0.80 4/0A TPX SVC 0.0091 157 1.2 1.71TOTAL =3.5 VOLTS TOTAL 3.2 VOLTS PM# 3527409911/12/21GDSI 3 VOLTAGE & FLICKER DROP CALCULATIONS LOADING CRITERIA:CLIMATE ZONE R WITH 4 TON A/C PM# 35274099 NEW SERVICE INFO:1,917 AVG. SQ.FT, 200 AMS JOB# 21-146 4/0A TPX SVC IN 3" CONDUIT T-17 LOTS 39/40 LOT 28 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 50 KVA PM TX 6 46 0.04687 2.16 50 KVA PM TX 1 1.2 1.20 4/0A TPX SEC 6 46 0.381 75 1.31 4/0A TPX SEC 0.0091 75 1.2 0.82 4/0A TPX SEC 3 27 0.381 74 0.76 4/0A TPX SEC 0.0091 74 1.2 0.81 4/0A TPX SVC 1 13.3 0.381 136 0.69 4/0A TPX SVC 0.0091 136 1.2 1.49 TOTAL =4.9 VOLTS TOTAL 4.3 VOLTS T-18 LOTS 34/35 LOT 30 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 8 58 0.02392 1.39 100 KVA PM TX 0.53 1.2 0.64 350A TPX SEC 6 46 0.258 64 0.76 350A TPX SEC 0.0062 64 1.2 0.48 4/0A TPX SEC 2 27 0.381 152 1.56 4/0A TPX SEC 0.0091 152 1.2 1.66 4/0A TPX SVC 1 13.3 0.381 129 0.65 4/0A TPX SVC 0.0091 129 1.2 1.41TOTAL =4.4 VOLTS TOTAL 4.2 VOLTS LOT 33 VOLTAGE DROP VOLTAGE FLICKER # CUSTOMERS KVA K DISTANCE TOTAL K DIST.A/C MULT.TOTAL 100 KVA PM TX 8 58 0.02392 1.39 100 KVA PM TX 0.53 1.2 0.64 4/0A TPX SEC 2 27 0.381 54 0.56 4/0A TPX SEC 0.0091 54 1.2 0.59 4/0A TPX SVC 1 13.3 0.381 139 0.70 4/0A TPX SVC 0.0091 139 1.2 1.52TOTAL =2.6 VOLTS TOTAL 2.7 VOLTS PM# 3527409911/12/21GDSI 4 SERVICE SUMMARY PM# 35274099200AMP PANELS 1602 (Stubs) Franchise Conduit 1602 (Stubs) Franchise 90 Deg. 24" R 1602 (Stubs) Franchise 22 Deg. 36" R 1602 (Stubs) Franchise 90 Deg. 36" R 1603 PVT. PRP. Conduit 1603 PVT. PRP. 22 DEG 36" R Total Service Length 1 61 1 1 1 25 1 100 2 6 1 25 1 45 3 6 1 27 1 474612514556127147 6 6 1 25 1 45 7 6 1 27 1 478612514596127147 10 6 1 30 1 50 11 6 1 30 1 50127911127112013791112511181478111251117 15 78 1 1 1 27 1 119168411125112317841112711251896111251136 19 6 1 25 1 45206127147216125145226127147 23 6 1 25 1 452461271472558111251972695111251134 27 95 1 1 1 25 1 134 28 95 1 1 1 27 1 13629881112511273088111271129 31 71 1 1 1 25 1 110 32 71 1 1 1 27 1 112331001251139343611125175 35 6 1 25 1 45 36 6 1 27 1 47376125145386125145396127147 40 6 1 25 1 454161271474266125110543661251105 44 58 1 25 1 97455812519746118111251157476125145 48 6 1 27 1 47 49 6 1 25 1 45506127147 Lot # SERVICE SUMMARY PM# 35274099200AMP PANELS 1602 (Stubs) Franchise Conduit 1602 (Stubs) Franchise 90 Deg. 24" R 1602 (Stubs) Franchise 22 Deg. 36" R 1602 (Stubs) Franchise 90 Deg. 36" R 1603 PVT. PRP. Conduit 1603 PVT. PRP. 22 DEG 36" R Total Service Length 52 6 1 25 1 4553901112511295490111271131 55 88 1 1 1 27 1 129 56 88 1 1 1 25 1 127575812519758581271995958125197 60 58 1 27 1 99615812519762581271996358125197 64 58 1 27 1 99657011125110966701112711116781111251120 68 81 1 1 1 27 1 1226986111251126708611127112871701251110 72 70 1 27 1 112 73 6 1 25 1 45746127147756125145 76 6 1 27 1 47 77 0 20 1 10878701112511097970111271111 80 6 1 25 1 45 81 6 1 27 1 47826125145836127147 Totals 3592 81 30 30 2121 82 6940 Lot # SERVICE SUMMARY PM# 35274099200AMP PANELS Total Number Of Lots 82 Total Meters 82 3" Conduit 3592 90 Deg. 24" Radius 8122 Deg. 36" Radius 3090 Deg. 36" Radius 30Bell Ends 81 Temporay Caps 81 3" Conduit 212122 Deg. 36" Radius 82Temporary Caps 82 Total Svc. Length 69404/0 Al Temp Caps 328 1/0 Al Temp Caps 164Front End Packs 82 1600 = LOC. 999 Results 1602 = LOC. 998 1603 = LOC. 999 CABLE PULLING CALCULATIONS PM# 35274099 1/0A MAXIMUM TENSION = 1688/1688 LBS (GRIP/PULLING EYE) DIRECTION OF PULL WITH LEAST TENSION AND LEAST # OF PULL SETUPS CONSIDERED LOCATION 2 LOCATION 23 (3-1/0A EPR IN 4" CONDUIT)(2-1/0A EPR IN 4" CONDUIT) BEND/STRAIGHT RUN TENSION OUT (LBS)BEND/STRAIGHT RUN TENSION OUT (LBS) SECTION 1 90 DEG, 3' RADIUS 4 SECTION 1 90 DEG, 3' RADIUS 2SECTION 2 22 DEG, 5' RADIUS 6 SECTION 2 11 DEG, 5' RADIUS 3 SECTION 3 22'25 SECTION 3 137'65SECTION 4 90 DEG, 5' RADIUS 46 SECTION 4 90 DEG, 5' RADIUS 105 SECTION 5 625'577 SECTION 5 178'186SECTION 6 22 DEG, 5' RADIUS 666 SECTION 6 11 DEG, 5' RADIUS 197 SECTION 7 22 DEG, 5' RADIUS 768 SECTION 7 90 DEG, 3' RADIUS 316 LOCATION 4 LOCATION 29 (3-1/0A EPR IN 4" CONDUIT)(2-1/0A EPR IN 4" CONDUIT) BEND/STRAIGHT RUN TENSION OUT (LBS)BEND/STRAIGHT RUN TENSION OUT (LBS) SECTION 1 22 DEG, 5' RADIUS 2 SECTION 1 90 DEG, 3' RADIUS 2 SECTION 2 22 DEG, 5' RADIUS 3 SECTION 2 11 DEG, 5' RADIUS 3 SECTION 3 22'22 SECTION 3 40'21 SECTION 4 90 DEG, 5' RADIUS 41 SECTION 4 90 DEG, 5' RADIUS 34SECTION 5 178'192 SECTION 5 178'116 SECTION 6 90 DEG, 5' RADIUS 345 SECTION 6 11 DEG, 5' RADIUS 123SECTION 7 397'683 SECTION 7 90 DEG, 3' RADIUS 196 SECTION 8 22 DEG, 5' RADIUS 788 SECTION 9 22 DEG, 5' RADIUS 908 LOCATION 38 (2-1/0A EPR IN 4" CONDUIT)LOCATION 6 (3-1/0A EPR IN 4" CONDUIT)BEND/STRAIGHT RUN TENSION OUT (LBS) SECTION 1 90 DEG, 3' RADIUS 2 BEND/STRAIGHT RUN TENSION OUT (LBS)SECTION 2 22 DEG, 5' RADIUS 3 SECTION 1 90 DEG, 3' RADIUS 4 SECTION 3 332'155 SECTION 2 22 DEG, 5' RADIUS 6 SECTION 4 22 DEG, 5' RADIUS 174 SECTION 3 114'103 SECTION 5 90 DEG, 3' RADIUS 279 SECTION 4 90 DEG, 5' RADIUS 185 SECTION 5 123'289 LOCATION 46 SECTION 6 22 DEG, 5' RADIUS 334 (3-1/0A EPR IN 4" CONDUIT) SECTION 7 22 DEG, 5' RADIUS 385 BEND/STRAIGHT RUN TENSION OUT (LBS)LOCATION 7 SECTION 1 90 DEG, 3' RADIUS 4 (2-1/0A EPR IN 4" CONDUIT)SECTION 2 22 DEG, 5' RADIUS 6SECTION 3 360'312 BEND/STRAIGHT RUN TENSION OUT (LBS)SECTION 4 22 DEG, 5' RADIUS 360 SECTION 1 90 DEG, 3' RADIUS 2 SECTION 5 90 DEG, 3' RADIUS 645 SECTION 2 11 DEG, 5' RADIUS 3 SECTION 3 114'55 LOCATION 69 SECTION 4 90 DEG, 5' RADIUS 88 (3-1/0A EPR IN 4" CONDUIT) SECTION 5 119'142SECTION 6 11 DEG, 5' RADIUS 151 BEND/STRAIGHT RUN TENSION OUT (LBS) SECTION 7 90 DEG, 3' RADIUS 242 SECTION 1 90 DEG, 3' RADIUS 4 SECTION 2 11 DEG, 5' RADIUS 5LOCATION 21 SECTION 3 256'223 (3-1/0A EPR IN 4" CONDUIT)SECTION 4 90 DEG, 5' RADIUS 400SECTION 5 257'618 BEND/STRAIGHT RUN TENSION OUT (LBS)SECTION 6 11 DEG, 5' RADIUS 664SECTION 1 90 DEG, 3' RADIUS 4 SECTION 7 90 DEG, 3' RADIUS 1190 SECTION 2 22 DEG, 5' RADIUS 6 SECTION 3 230'202 LOCATION 72 SECTION 4 22 DEG, 5' RADIUS 233 (2-1/0A EPR IN 4" CONDUIT) SECTION 5 90 DEG, 3' RADIUS 417 BEND/STRAIGHT RUN TENSION OUT (LBS) SECTION 1 90 DEG, 3' RADIUS 2SECTION 2 11 DEG, 5' RADIUS 3 SECTION 3 178'84 SECTION 4 90 DEG, 5' RADIUS 135 SECTION 5 503'365 SECTION 6 11 DEG, 5' RADIUS 386 SECTION 7 90 DEG, 3' RADIUS 619 PM# 3527409911/12/21GDSI 1 Pole ID:21-146 NB PL LOC 800.pplx O-Calc®Pro Analysis -GO 95 Friday,November 12,2021 11:13 AM User:BRubio GDSINC OCP:6.02 *Includes Load Factor(s)Page 1 of 4 2 Worst Wind Per Guy Wire 3Wind At 266.3° Pole Num:Unset Pole Length /Class:55 /1 Code:GO 95 Structure Type:Unguyed Tangent PM Order Number 35274099 Species:DOUGLAS FIR GO 95 Rule:At Installation (New)Pole Strength Factor:0.33 Estimator LAN ID Unset Setting Depth (ft):8.5 Construction Grade:B Transverse Wind LF:1.00 Sketch Location 800 G/L Circumference (in):45.51 Loading District:Light Wire Tension LF:1.00 Joint Pole Number Unset G/L Fiber Stress (psi):7,600 Ice Thickness (in):0.00 Vertical LF:1.00 Notification 121534031 Allowable Stress (psi):2,485 Wind Speed (mph):55.90 Pole Factor of Safety:4.82 PLDBID Unset Fiber Stress Ht.Reduc:No Wind Pressure (psf):8.00 Vertical Factor of Safety:34.88 Latitude:0 Longitude:0 Elevation:0'Bending Factor of Safety:4.87 Pole Capacity Utilization (%) Crossarm allowance 300 lbs Height (ft) Wind Angle (deg) Maximum 62.2 0.0 266.3 Groundline 62.2 0.0 266.3 Vertical 8.6 25.8 266.3 Pole Moments (ft-lb) Crossarm allowance 300 lbs Load Angle (deg) Wind Angle (deg) Max Cap Util 38,045 268.5 266.3 Groundline 38,045 268.5 266.3 GL Allowable 61,786 Overturn 126,000 Pole ID:21-146 NB PL LOC 800.pplx O-Calc®Pro Analysis -GO 95 Friday,November 12,2021 11:13 AM User:BRubio GDSINC OCP:6.02 *Includes Load Factor(s)Page 2 of 4 2 Worst Wind Per Guy Wire 3Wind At 266.3° Groundline Load Summary -Reporting Angle Mode:Load -Reporting Angle:268.5° Shear Load* (lbs) Applied Load (%) Bending Moment (ft-lb) Applied Moment (%) Pole Capacity (%) Bending Stress (+/-psi) Vertical Load (lbs) Vertical Stress (psi) Total Stress (psi) Pole Capacity (%) Powers 670 60.3 27,594 72.5 44.7 1,110 479 3 1,112 44.8 GenericEquipments 12 1.1 474 1.3 0.8 19 60 0 19 0.8 Pole 358 32.2 8,164 21.5 13.2 328 2,070 13 341 13.7 Crossarms 2 0.2 89 0.2 0.1 4 70 0 4 0.2 Risers 61 5.5 1,445 3.8 2.3 58 35 0 58 2.3 Insulators 7 0.6 279 0.7 0.5 11 33 0 11 0.5 Pole Load 1,110 100.0 38,045 100.0 61.6 1,530 2,747 17 1,546 62.2 Pole Reserve Capacity 23,741 38.4 955 939 37.8 Load Summary by Owner -Reporting Angle Mode:Load -Reporting Angle:268.5° Shear Load* (lbs) Applied Load (%) Bending Moment (ft-lb) Applied Moment (%) Pole Capacity (%) Bending Stress (+/-psi) Vertical Load (lbs) Vertical Stress (psi) Total Stress (psi) Pole Capacity (%) PG&E 752 67.8 29,881 78.5 48.4 1,202 677 4 1,206 48.5 Pole 358 32.2 8,164 21.5 13.2 328 2,070 13 341 13.7 Totals:1,110 100.0 38,045 100.0 61.6 1,530 2,747 17 1,546 62.2 Detailed Load Components: Power Owner Height (ft) Horiz. Offset (in) Cable Diameter (in) Sag at Max Temp (ft) Cable Weight (lbs/ft) Lead/Span Length (ft) Span Angle (deg) Wire Length (ft) Tension (lbs) Tension Moment* (ft-lb) Offset Moment* (ft-lb) Wind Moment* (ft-lb) Moment at GL* (ft-lb) Primary 715 AAC (VIOLET) SHORT SPAN PG&E 40.82 44.48 0.9740 3.94 0.707 216.0 180.0 216.1 2,195 2,334 -281 2,859 4,912 Primary 715 AAC (VIOLET) SHORT SPAN PG&E 40.82 44.48 0.9740 4.45 0.707 236.0 358.0 236.1 2,195 798 -307 3,130 3,621 Primary 715 AAC (VIOLET) SHORT SPAN PG&E 40.82 44.48 0.9740 3.94 0.707 216.0 180.0 216.1 2,195 2,334 279 2,859 5,472 Primary 715 AAC (VIOLET) SHORT SPAN PG&E 40.82 44.48 0.9740 4.45 0.707 236.0 358.0 236.1 2,195 798 304 3,130 4,232 Primary 715 AAC (VIOLET) SHORT SPAN PG&E 40.82 19.14 0.9740 3.94 0.707 216.0 180.0 216.1 2,195 2,334 113 2,859 5,306 Primary 715 AAC (VIOLET) SHORT SPAN PG&E 40.82 19.14 0.9740 4.45 0.707 236.0 358.0 236.1 2,195 798 124 3,130 4,052 Totals:9,394 233 17,968 27,594 Pole ID:21-146 NB PL LOC 800.pplx O-Calc®Pro Analysis -GO 95 Friday,November 12,2021 11:13 AM User:BRubio GDSINC OCP:6.02 *Includes Load Factor(s)Page 3 of 4 2 Worst Wind Per Guy Wire 3Wind At 266.3° GenericEquipment Owner Height (ft) Horiz. Offset (in) Offset Angle (deg) Rotate Angle (deg) Unit Weight (lbs) Unit Height (in) Unit Depth (in) Unit Diameter (in) Unit Length (in) Offset Moment* (ft-lb) Wind Moment* (ft-lb) Moment at GL* (ft-lb) Cylinder Disconnect Switch 1 PG&E 36.92 44.03 180.0 0.0 20.00 18.00 --4.00 ---73 148 75 Cylinder Disconnect Switch 2 PG&E 36.92 44.03 180.0 0.0 20.00 18.00 --4.00 --73 148 221 Cylinder Disconnect Switch 3 PG&E 36.92 18.07 180.0 0.0 20.00 18.00 --4.00 --30 148 178 Totals:30 444 474 Crossarm Owner Height (ft) Horiz. Offset (in) Offset Angle (deg) Rotate Angle (deg) Unit Weight (lbs) Unit Height (in) Unit Depth (in) Unit Length (in) Offset Moment* (ft-lb) Wind Moment* (ft-lb) Moment at GL* (ft-lb) Normal 8 Composite TangentArm PG&E 40.00 6.52 0.0 0.0 34.00 4.63 3.63 96.00 0 62 62 Normal Cutout Arm-3 Wire PG&E 37.00 5.90 0.0 0.0 36.00 4.00 2.00 92.00 0 28 28 Totals:-1 90 89 Riser Owner Height (ft) Horiz. Offset (in) Offset Angle (deg) Rotate Angle (deg) Unit Weight (lbs) Unit Height (in) Unit Depth (in) Unit Diameter (in) Unit Length (in) Offset Moment* (ft-lb) Wind Moment* (ft-lb) Moment at GL* (ft-lb) Riser 315.0°H:35.0 Riser PG&E 35.00 7.53 315.0 315.0 35.00 420.00 3.50 3.50 420.00 15 1,430 1,445 Totals:15 1,430 1,445 Insulator Owner Height (ft) Horiz. Offset (in) Offset Angle (deg) Rotate Angle (deg) Unit Weight (lbs) Unit Diameter (in) Unit Length (in) Offset Moment* (ft-lb) Wind Moment* (ft-lb) Moment at GL* (ft-lb) Pin Insulator PG&E 40.19 44.00 81.6 0.0 6.00 5.50 7.50 0 92 92 Pin Insulator PG&E 40.19 -44.00 278.4 0.0 6.00 5.50 7.50 0 92 92 Pin Insulator PG&E 40.19 -18.00 289.9 0.0 6.00 5.50 7.50 0 92 92 Bolt Cutout PG&E 37.17 44.00 82.4 180.0 5.00 3.00 0.10 0 1 1 Bolt Cutout PG&E 37.17 -44.00 277.6 180.0 5.00 3.00 0.10 0 1 1 Bolt Cutout PG&E 37.17 -18.00 288.1 180.0 5.00 3.00 0.10 0 1 1 Totals:0 279 279 Pole Buckling Buckling Constant Buckling Column Height* (ft) Buckling Section Height (%Buckling Col.Hgt.) Buckling Section Diameter (in) Minimum Buckling Diameter at GL (in) Diameter at Tip (in) Diameter at GL (in) Modulus of Elasticity (psi) Pole Density (pcf) Ice Density (pcf) Pole Tip Height (ft) Buckling Load Capacity at Height (lbs) Buckling Load Applied at Height (lbs) Buckling Load Factor of Safety 2.00 25.82 33.39 13.39 7.85 8.60 14.49 2.38e+6 60.00 57.00 46.50 31,797 319.46 11.63 Pole ID:21-146 NB PL LOC 800.pplx O-Calc®Pro Analysis -GO 95 Friday,November 12,2021 11:13 AM User:BRubio GDSINC OCP:6.02 *Includes Load Factor(s)Page 4 of 4 2 Worst Wind Per Guy Wire 3Wind At 266.3° Notes Date Author Description 1/30/2018 ben1 Outside top (pin/post)insulators are at 44",inside are at 18" M150591 PUPI series 2200 Outside top (pin/post)insulators are at 44",inside are at 18". Outside Dead-Ends are at 40.5". Comes w/bushings for insulator pins8/3/2015 ben1 Install C/O Arm min 2.5 ft below Primary Conductor Install C/O Arm min 2.5 ft below Primary Conductor GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE GIACALONE ! " # $% ! &’()*)!’ $( ! ’ $( !’ $% !’ $* !’ $$ !’ ** ’ $( !’ $% !’ $!’ $$ !