Loading...
HomeMy WebLinkAbout2023 FMC1 Jennifer Pruitt Subject:SA098, AT&T Annual Monitor Certification & Spill Bucket Testing Notification (BKFDCA14), Bakersfield Location:3221 S. H STREET, BAKERSFIELD, CA 93304-5649 Start:Tue 10/17/2023 11:00 AM End:Tue 10/17/2023 1:00 PM Recurrence:(none) Meeting Status:Meeting organizer Organizer:Simplex Communication Required Attendees:AGUILAR, ADOLFO; MEDINA, ELOISA; 'FLORES, CECILIA'; 'HAYN, CINDY H (ATTSI)' (ch1921@att.com) ; Carlos Cardenas; Jennifer Pruitt; Maria Figueroa; Krystine Gossett; Eric Durham Categories:Annual Monitoring Certification & Spill Bucket Testing, Legacy S Site There is an AT&T Annual monitor certification and spill bucket test scheduled for this location on the date and time indicated. NOTE: -Next Overfill Test of the Overfill Alarm due in 2025 -Testing Permit #23-10000040 SA098 3221 S. H STREET BAKERSFIELD 93304-5649     TEST DUE DATE 10/21/2023    PERMIT REQUIRED for TESTING  1. BILLING & PERMIT STATEMENT - FEE SCHEDULE (PDF) 2. UST TESTING APPLICATION (PDF)    Please contact the Compliance Manager with any questions and/or comments at:  simplexcommunication@tait.com    714.560.8200    Environmental Health/CUPA Contact Information:   Bakersfield City Fire Department  2101 H Street  Bakersfield, CA 93301  Method of Notification: Email  Contact (Once Permit is Approved):  https://www.bakersfieldcity.us/1048/Inspection‐Request    2 Test Results Submittal: USTResults@bakersfieldfire.us    1 Jennifer Pruitt From:Luke Preece <lpreece@bakersfieldfire.us> Sent:Tuesday, August 29, 2023 12:53 PM To:Carlos Cardenas Cc:Jennifer Pruitt Subject:RE: ***Scheduling Request***AT&T Annual October Testing - Bakersfield Fire Dept. External Email.    Carlos,    These times are good with me. I have you on the calendar.     Thank you        Luke Preece Fire Prevention/Environmental Officer Bakersfield Fire Department email: lpreece@bakersfieldfire.us web: www.bakersfieldfire.us phone: 661-326-3659       From: Carlos Cardenas <ccardenas@TAIT.COM>   Sent: Tuesday, August 29, 2023 11:20 AM  To: Luke Preece <lpreece@bakersfieldfire.us>  Cc: Jennifer Pruitt <jpruitt@TAIT.COM>  Subject: ***Scheduling Request***AT&T Annual October Testing ‐ Bakersfield Fire Dept.    CAUTION: This email originated from outside your organization. Exercise caution when opening attachments or clicking  links, especially from unknown senders.  Hello Inspector Preece,    Thank you for the voicemail. Per your available dates, I was hoping we could schedule tesƟng for the following dates and  Ɵmes:    SA004, AT&T Annual Monitor Certification,  PLLD Testing & Spill Bucket Testing  Notification (BKFDCA12), Bakersfield  1918 M STREET  BAKERSFIELD, CA 93301  Mon 10/16/2023  9:00 AM  Permit # 23-10000038  SA004, AT&T Annual Precision Line Testing  Notification (BKFDCA12), Bakersfield  1918 M STREET  BAKERSFIELD, CA 93301  Mon 10/16/2023  9:00 AM  Permit # 23-10000039  SA002, AT&T Annual Monitor Certification  & Spill Bucket Testing Notification  (BKFDCA01), Bakersfield  1520 20TH ST  BAKERSFIELD, CA 93301  Tue 10/17/2023  9:00 AM  Permit # 23-10000037  2 SA098, AT&T Annual Monitor Certification  & Spill Bucket Testing Notification  (BKFDCA14), Bakersfield  3221 S. H STREET  BAKERSFIELD, CA 93304  Tue 10/17/2023  11:00 AM  Permit # 23-10000040      Carlos E. Cardenas | TAIT Environmental Services, Inc. Project Manager 701 N. Parkcenter Dr., Santa Ana, CA 92705 P: 714-567-6418 C: 909-230-8256 ccardenas@tait.com | www.tait.com               This email message, including any attachment(s), is intended only for the recipient(s) named above. It may contain information that is confidential, privileged, or protected by law. The unlawful use, distribution, or publication of this information is strictly prohibited. If you receive this communication in error, please notify the sender immediately by return email and delete the original message, including all attachment(s).    Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages SA098 ✔ 10023352 10/17/2023 10/17/2023 PACIFIC BELL TELEPHONE CO. DBA AT&T CALIFORNIA 3221 S. H ST. BAKERSFIELD 93304 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Eric Durham 588098 10275565 5/1/2025 Veeder Root A23191 4/27/2024 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications?܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid?܆܆܆܆ Are the audible and visual alarms operational?܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational?܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment?܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed?܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational?܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational?܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS 350 PLUS 324.01 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794390-420 / 940306 Annular Sensor ✔ L2 794380-208 / 762065 Fill Sump Sensor ✔ L3 794380-208 / 519636 Piping Sump Sensor ✔ L4 794380-208 / 492898 Transition Box Sensor ✔ L5 794390-420 / 619734 Generator Room Piping Pan Sensor ✔ Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated?܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected?܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test?܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements?܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 ✔ Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults?܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational?܆܆ ܆܆ ܆܆ Was accuracy of system’s product level readings tested?܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested?܆܆ ܆܆ ܆܆ Were all probes reinstalled properly?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ✔ ✔ ✔ ✔ ✔ ✔ Tank 1 Diesel 847390-107 / 726884 SA098U001 ✔ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 10/17/2023 Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages Environmenta an Signature SA098 ✔ 10023352 10/17/2023 10/17/2023 PACIFIC BELL TELEPHONE CO. DBA AT&T CALIFORNIA 3221 S. H ST. BAKERSFIELD 93304 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Eric Durham 588098 10275565 5/1/2025 Franklin Fueling Systems 7/19/2025 PEI / RP 1200 Spill Containment SA098U001 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. ✔ ✔ SA098U001 Phil Tite ✔ ✔ ✔ ✔ I50301 OCT 18, 2023 6:52 AM # 1:BKFDCA14 SA098 S-S I50302 OCT 18, 2023 6:52 AM # 2:3221 S. H ST. I50303 OCT 18, 2023 6:52 AM # 3:BAKERSFIELD,CA 93304 I50304 OCT 18, 2023 6:52 AM # 4:661-832-8370 I51700 OCT 18, 2023 6:53 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 OCT 18, 2023 6:53 AM MON DD YYYY HH:MM:SS xM I10200 OCT 18, 2023 6:53 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163785 161800 2 INTERSTITIAL BD 200879 199435 3 UNUSED 10306571 10234923 4 UNUSED 10265262 10216210 5 UNUSED 10261818 10225825 6 UNUSED 10249310 10216667 7 UNUSED 10253984 10221375 8 UNUSED 10247323 10224077 9 RELAY BOARD 14983 14981 10 UNUSED 10251789 10223827 11 UNUSED 10242063 10217411 12 UNUSED 10251033 10226112 13 UNUSED 10239736 10220728 14 UNUSED 10246737 10222457 15 UNUSED 10242820 10222556 16 UNUSED 10238506 10217014 COMM 1 FAXMODEM BOARD 40172 40086 COMM 2 UNUSED 10240833 10217967 COMM 3 UNUSED 10246661 10224741 COMM 4 UNUSED 10237503 10219795 COMM 5 UNUSED 10242385 10219298 COMM 6 UNUSED 10240341 10226072 I60100 OCT 18, 2023 6:54 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA098U001 ON 2 OFF 3 OFF 4 OFF I60200 OCT 18, 2023 6:54 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 2 3 4 I60300 OCT 18, 2023 6:54 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 1 2 2 3 3 4 4 I60400 OCT 18, 2023 6:54 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 6016 2 5036 3 0 4 0 I60700 OCT 18, 2023 6:54 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA098U001 95.75 2 92.00 3 0.00 4 0.00 I60900 OCT 18, 2023 6:54 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 0.000450 2 0.000450 3 0.000000 4 0.000000 I61200 OCT 18, 2023 6:54 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 DIESEL TK#SA098U001 NONE NONE 2 NONE NONE 3 NONE NONE 4 NONE NONE I62100 OCT 18, 2023 6:54 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 2000 2 3000 3 0 4 0 I62200 OCT 18, 2023 6:54 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 4784 2 4784 3 0 4 0 I62300 OCT 18, 2023 6:54 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 4532 2 4532 3 0 4 0 I62400 OCT 18, 2023 6:54 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA098U001 2.0 I62800 OCT 18, 2023 6:54 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 6016 2 5036 3 0 4 0 I62900 OCT 18, 2023 6:54 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 3000 2 3525 3 0 4 0 I70300 OCT 18, 2023 6:54 AM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR SPACE SENSOR TRI-STATE (SINGLE FLOAT) 2 FILL SUMP SENSOR TRI-STATE (SINGLE FLOAT) 3 PIPING SUMP SENSOR TRI-STATE (SINGLE FLOAT) 4 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 5 PIPING PAN TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 OCT 18, 2023 6:55 AM SOFTWARE REVISION LEVEL VERSION 324.01 SOFTWARE# 346324-100-B CREATED - 03.11.10.17.15 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 OCT 18, 2023 6:55 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 10-17-23 12:58PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-17-23 12:58PM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 10-17-23 12:56PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-17-23 12:56PM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 10-17-23 12:54PM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 10-17-23 12:54PM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 10-17-23 12:52PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM ALARM 10-17-23 12:47PM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM CLEAR 10-17-23 12:44PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-17-23 12:44PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-17-23 12:43PM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM ALARM 10-17-23 12:43PM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 10-17-23 12:42PM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 10-17-23 12:42PM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 10-17-23 12:41PM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 10-17-23 12:39PM L 5 PIPE PIPING PAN FUEL ALARM ALARM 10-17-23 12:36PM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-17-23 12:36PM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-17-23 12:34PM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 10-17-23 12:31PM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 10-17-23 12:31PM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 10-17-23 12:29PM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 10-17-23 12:28PM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 10-17-23 12:25PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 10-21-22 9:42AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-21-22 9:41AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-21-22 9:41AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM ALARM 10-21-22 9:37AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 10-21-22 9:34AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 10-21-22 9:31AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM CLEAR 10-21-22 9:30AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-21-22 9:30AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-21-22 9:29AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM ALARM 10-21-22 9:29AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-21-22 9:29AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-21-22 9:27AM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 10-21-22 9:23AM L 5 PIPE PIPING PAN FUEL ALARM ALARM 10-21-22 9:23AM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 10-21-22 9:20AM L 5 PIPE PIPING PAN FUEL ALARM ALARM 10-21-22 9:20AM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-21-22 9:18AM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-21-22 9:16AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 10-21-22 9:15AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 10-21-22 9:14AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 10-21-22 9:11AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 10-21-22 9:09AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 10-21-22 9:05AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 10-21-22 9:04AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 10-20-21 9:47AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-20-21 9:46AM I11200 OCT 18, 2023 6:56 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 10-17-23 1:25PM SYSTEM PRINTER ERROR ALARM 10-17-23 1:25PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-17-23 12:58PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-17-23 12:58PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-17-23 12:58PM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-17-23 12:58PM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-17-23 12:54PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-17-23 12:47PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-17-23 12:44PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-17-23 12:43PM SYSTEM PRINTER ERROR CLEAR 4-20-23 8:11PM SYSTEM PAPER OUT CLEAR 4-20-23 8:11PM SYSTEM PRINTER ERROR ALARM 4-20-23 8:11PM SYSTEM PAPER OUT ALARM 4-20-23 8:11PM SYSTEM PRINTER ERROR CLEAR 2-23-23 6:06PM SYSTEM PAPER OUT CLEAR 2-23-23 6:06PM SYSTEM PRINTER ERROR ALARM 2-23-23 6:06PM SYSTEM PAPER OUT ALARM 2-23-23 6:06PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-21-22 9:42AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-21-22 9:42AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-21-22 9:42AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-21-22 9:37AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-21-22 9:33AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-21-22 9:33AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-21-22 9:30AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-21-22 9:27AM SYSTEM PRINTER ERROR CLEAR 10-20-21 10:45AM SYSTEM PAPER OUT CLEAR 10-20-21 10:45AM SYSTEM PRINTER ERROR ALARM 10-20-21 10:44AM SYSTEM PAPER OUT ALARM 10-20-21 10:44AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-20-21 9:47AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-20-21 9:47AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-20-21 9:47AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-20-21 9:42AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-20-21 9:37AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-20-21 9:37AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-20-21 9:34AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-20-21 9:34AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-09-20 9:31AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-09-20 9:28AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-16-19 12:42PM I20600 OCT 18, 2023 6:57 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 TANK ALARM HISTORY TANK 1 DIESEL TK#SA098U001 SETUP DATA WARNING APR 26, 2004 3:45 PM LEAK ALARM JUN 2, 2006 9:35 AM HIGH WATER ALARM OCT 17, 2023 12:47 PM OCT 21, 2022 9:37 AM OCT 20, 2021 9:42 AM OVERFILL ALARM OCT 17, 2023 12:54 PM OCT 17, 2023 12:52 PM OCT 21, 2022 9:31 AM LOW PRODUCT ALARM OCT 17, 2023 12:43 PM OCT 21, 2022 9:29 AM OCT 20, 2021 9:34 AM SUDDEN LOSS ALARM JUN 2, 2006 9:04 AM HIGH PRODUCT ALARM OCT 17, 2023 12:54 PM OCT 21, 2022 9:33 AM OCT 20, 2021 9:37 AM INVALID FUEL LEVEL OCT 5, 2018 9:29 AM OCT 26, 2016 9:33 AM NOV 12, 2015 9:28 AM PROBE OUT OCT 17, 2023 12:56 PM OCT 17, 2023 12:43 PM OCT 21, 2022 9:41 AM HIGH WATER WARNING OCT 17, 2023 12:47 PM OCT 21, 2022 9:37 AM OCT 20, 2021 9:42 AM DELIVERY NEEDED OCT 17, 2023 12:43 PM OCT 21, 2022 9:27 AM OCT 20, 2021 9:47 AM MAX PRODUCT ALARM OCT 9, 2020 9:35 AM OCT 16, 2019 12:29 PM OCT 5, 2018 9:39 AM PERIODIC TEST FAIL JUN 14, 2006 1:38 AM JUN 3, 2006 9:55 AM MAY 11, 2006 7:55 AM CSLD INCR RATE WARN NOV 9, 2004 11:34 AM OCT 23, 2004 10:39 AM LOW TEMP WARNING OCT 17, 2023 12:58 PM OCT 21, 2022 9:42 AM OCT 9, 2020 9:39 AM I30200 OCT 18, 2023 6:57 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR SPACE SENSOR OCT 17, 2023 12:25 PM FUEL ALARM OCT 21, 2022 9:04 AM FUEL ALARM OCT 20, 2021 9:13 AM FUEL ALARM 2 FILL SUMP SENSOR OCT 17, 2023 12:42 PM FUEL ALARM OCT 17, 2023 12:29 PM FUEL ALARM OCT 21, 2022 9:09 AM FUEL ALARM 3 PIPING SUMP SENSOR OCT 17, 2023 12:31 PM FUEL ALARM OCT 21, 2022 9:14 AM FUEL ALARM OCT 20, 2021 9:22 AM FUEL ALARM 4 TRANSITION SUMP OCT 17, 2023 12:34 PM FUEL ALARM OCT 21, 2022 9:16 AM FUEL ALARM OCT 20, 2021 9:25 AM FUEL ALARM 5 PIPING PAN OCT 17, 2023 12:36 PM FUEL ALARM OCT 21, 2022 9:23 AM FUEL ALARM OCT 21, 2022 9:20 AM FUEL ALARM         Identification of Test Procedures for Secondary Containment Testing      To Whom It May Concern:     Tait Environmental Services, Inc., utilizes the following procedures when conducting Secondary  Containment Testing:  1) Containment Sumps, Transition Sumps, UDCs – Tait follows PEI‐RP1200‐17 Section 6.6 for the  accelerated test method. Tait uses the Incon TS‐1000 hydrostatic test equipment following the  attached procedures.  2) Spill Buckets; Direct Bury & Contained in Sumps – Spill buckets contained in sumps are tested  per PEI‐1200‐17, Section 6.2, however Tait Pass/Fail threshold is 0” drop in one hour. Direct Bury  Spill Buckets are test the same as containment sumps per PEI‐1200‐17, Section 6.6.  3) Tank Annular Space – testing is conducted per PEI‐1200‐17, Section 4.2  4) Piping Secondary Containment – Testing is conducted per PEI‐RP1200‐17, Section 5.3    Please consider this letter as our Test Procedure utilized when conducting Secondary Containment  Testing in lieu of either parts or the whole RP1200 document due to copyright infringement.