HomeMy WebLinkAboutFMC 2023Appendix VI
Underground Storage Tank
Monitoring System Certification Form
CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification,
ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-
Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank,
VPH = Vacuum/Pressure/Hydrostatic
Page 1 of 6
TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month
1. FACILITY INFORMATION
CERS ID Certification Date
Facility Name
Facility Address City ZIP Code
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Certification Phone
Mailing Address
Service Technician Performing Test
Contractor/Tank Tester License Number
ICC Number ICC Expiration Date
3. TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that the monitoring system is operational in accordance with California Code
of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting
documentation is attached; and all information contained herein is accurate.
Service Technician Signature Date Total # of Pages
10125802 12/14/2023
Samco White Ln
3300 White Ln Bakersfield 93309
Nwestco LLC (800) 339-9930
2209 Zeus Court, Bakersfield, CA 93308
Brandon Nunez
1073967
10226373 9/6/2024
VeederRoot - C32655 10/11/24
Vaporless manufacturing Inc - 5265 10/21/24
Phil-Tite - 1016703714 12/07/24
12/14/2023 5
Underground Storage Tank
Monitoring System Certification Form
Page 2 of 6
5. MONITORING SYSTEM AND PROGRAMMING
A separate Monitoring System Certification Form must be prepared for each control panel.
Make of Monitoring System
Control Panel
Model of Monitoring System
Control Panel
Software Version Installed
Attach the post-certification reports if the monitoring system is capable of generating
either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA
All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆
Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆
Are the audible and visual alarms operational? ܆܆܆܆
All sensors have been: 1) visually inspected for wiring kinks, breaks and residual
buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆
Are all sensors installed to detect a release at the earliest opportunity in the
secondary containment? ܆܆܆܆܆܆
The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆
Was the monitoring control panel’s backup battery visually inspected, functionally
tested, and confirmed operational? ܆܆܆܆܆܆
Does the flow of fuel stop at the dispenser if a release is detected in the under-
dispenser containment? ܆܆܆܆܆܆
Does the turbine automatically shut down if the piping secondary containment
monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆
Does the turbine automatically shut down if the piping secondary containment
monitoring system detects a release? Which sensors initiate positive shut down?
(Check all that apply) ܆ Sump ܆ UDC
܆܆܆܆܆܆
If monitoring system alarms are relayed to a remote monitoring center, is all
communication equipment operational? ܆܆܆܆܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
VedderRoot TLS-350
336.01
Underground Storage Tank
Monitoring System Certification Form
Page 3 of 6
6. SENSOR TESTING RESULTS
List only sensors tested on date of this certification. List “Sensor ID” as labeled in system
programming. Additional copies of this page may be attached to accommodate all sensors tested.
Sensor ID Sensor Model Component(s) Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
L1 208 Disp 1-2
L2 208 Disp 5-6
L3 208 Disp 3-4
L4 208 Disp 7-8
L5 208 Disp 9-10
L7 208 Disp 11-12
L9 208 87 STP
L10 420 87 ANN
L11 208 87 FILL
L12 420 91 ANN
L13 208 91 STP
L14 208 91 FILL
Underground Storage Tank
Monitoring System Certification Form
Page 4 of 6
7. LINE LEAK DETECTOR TESTING
܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.)
Simulated release rate verified: (Check all that apply.)
܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA
Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆
For emergency generator tank systems, does the LLD create an audible and visual
alarm when a leak is detected? ܆܆ ܆܆ ܆܆
For mechanical LLDs, does the LLD restrict the flow through the pipe when a
release is detected? ܆܆ ܆܆ ܆܆
For electronic LLDs, does the turbine automatically shut off when a release is
detected? ܆܆ ܆܆ ܆܆
For electronic LLDs, does the turbine automatically shut off if any portion of the
monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆
For electronic LLDs, does the turbine automatically shut off if any portion of the
monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆
For electronic LLDs, have all accessible wiring connections been visually inspected
for kinks and breaks? ܆܆ ܆܆ ܆܆
Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆
Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆
LLD ID LLD Model Lines Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
T1 Fx1v 87 Unleaded
T2 Fx1v 91 Premium
Underground Storage Tank
Monitoring System Certification Form
Page 5 of 6
8. IN-TANK GAUGING TESTING
܆܆ Check this box if tank gauging is used only for inventory control.
܆܆ Check this box if NO tank gauging equipment is installed.
(Do not complete this section if either box is checked.)
Yes No NA
All wiring has been: 1) visually inspected for kinks, breaks and proper entry and
termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆
Were all in-tank gauging probes visually inspected for damage and residue buildup
to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆
Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆
Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆
Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆
Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆
Probe ID Probe Model Tanks Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
9. COMMENTS
Describe all answers marked “No” or “Fail” and proposed remedy.
List all monitoring equipment either replaced or repaired.
܆܆
APPENDIX C-10
SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,' 6KHDU9DOYH7\SH3URGXFW9DSRU,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//& Samco White Ln3300 White LnBakersfield101258023-47-8 11-12MPDMPDMPDMPDMPDMPD1-25-69-10ProductProductProductProductProductProductBrandon Nunez
Appendix VIII
Underground Storage Tank
Spill Container Testing Report Form
CERS = California Environmental Reporting System, ID = Identification, ICC = International Code
Council
Page 1 of 2
TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month
1. FACILITY INFORMATION
CERS ID
Test Date
Facility Name
Facility Address
City
ZIP Code
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Test
Phone
Mailing Address
Service Technician Performing Test
Contractor/Tank Tester License Number
ICC Number
ICC Expiration Date
3. TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
4. TEST PROCEDURE INFORMATION
Test Procedures Used Components Tested
5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that each spill container was tested in accordance with California Code of
Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting
documentation is attached; and all information contained herein is accurate. I understand
that test procedures shall be made available upon request by the governing authority.
Service Technician Signature Date
Total # of Pages
10125802 12/14/2023
Samco White Ln
3300 White Ln Bakersfield 93309
Nwestco LLC (800) 339-9930
2209 Zeus Court, Bakersfield, CA 93308
Brandon Nunez
1073967
10226373 9/6/2024
Phil-Tite - 1016703714 12/7/24
PEI-1200 1 Hour Hydrostatic All spill containers
12/14/2023 2
Underground Storage Tank
Spill Container Testing Report Form
Additional copies of this page may be attached.
Page 2 of 2
6. SPILL CONTAINER DETAILS
Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer
Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic
Tank ID
Spill Container Manufacturer:
Method of Cathodic Protection ܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
Is the spill container minimum
capacity five gallons excluding
riser volume?
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
Method to keep spill container
empty
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
Spill Container Test Results ܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
Tank ID
Spill Container Manufacturer:
Method of Cathodic Protection ܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
܆܆ Nonmetallic
܆܆ Other
Is the spill container minimum
capacity five gallons excluding
riser volume?
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
܆܆ Yes
܆܆ No*
Method to keep spill container
empty
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
܆܆ Drain
܆܆ Pump
܆܆ Other
Spill Container Test Results ܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
܆܆ Pass
܆܆ Fail
1 8. COMMENTS
Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy.
* Mark here if:
Spill containers do not have a minimum capacity of five gallons and require replacement.
T1: 87 UNL
Phil-Tite
T2: 91 PNL
Phil-Tite
SamCo White Lane System Setup
Responses Received:
200
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
DEC 14, 2023 9:00 AM
TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE
1 SUPREM 5693 46.07 0.0 61.0 6307
2 UNLEADED 9262 69.21 0.8 56.8 2738
I90500
DEC 14, 2023 9:00 AM
SOFTWARE REVISION LEVEL
VERSION 336.01
SOFTWARE# 346336-100-B
CREATED - 20.04.26.20.30
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
ISD/APM
I50500
DEC 14, 2023 9:00 AM
SYSTEM TYPE AND LANGUAGE FLAG
SYSTEM UNITS
U.S.
SYSTEM LANGUAGE
ENGLISH
SYSTEM DATE/TIME FORMAT
MON DD YYYY HH:MM:SS xM
I50201
DEC 14, 2023 9:00 AM
SHIFT TIME 1 : DISABLED
I50202
DEC 14, 2023 9:00 AM
SHIFT TIME 2 : DISABLED
I50203
DEC 14, 2023 9:00 AM
SHIFT TIME 3 : DISABLED
I50204
DEC 14, 2023 9:00 AM
SHIFT TIME 4 : DISABLED
I54600
DEC 14, 2023 9:00 AM
TANK PER TST NEEDED WRN: DISABLED
I54900
DEC 14, 2023 9:00 AM
TANK ANN TST NEEDED WRN: DISABLED
I55300
DEC 14, 2023 9:00 AM
LINE RE-ENABLE METHOD
PASS LINE TEST
I55600
DEC 14, 2023 9:00 AM
LINE PER TST NEEDED WRN: DISABLED
I55900
DEC 14, 2023 9:00 AM
LINE ANN TST NEEDED WRN: DISABLED
I50D00
DEC 14, 2023 9:00 AM
PRINT TC VOLUMES
ENABLED
I50E00
DEC 14, 2023 9:00 AM
TEMP COMPENSATION
VALUE (DEG F ): 60.0
I60B00
DEC 14, 2023 9:00 AM
STICK HEIGHT OFFSET ENABLE STATUS
DISABLED
I51400
DEC 14, 2023 9:00 AM
H-PROTOCOL DATA FORMAT
HEIGHT
I51A01
DEC 14, 2023 9:00 AM
DAYLIGHT SAVING TIME
ENABLED OFF
I51B00
DEC 14, 2023 9:00 AM
DAYLIGHT SAVING TIME
START DATE MAR WEEK 2 SUN 2:00 AM
END DATE NOV WEEK 1 SUN 2:00 AM
I51600
DEC 14, 2023 9:00 AM
RE-DIRECT LOCAL PRINTOUT
DISABLED
I50400
DEC 14, 2023 9:00 AM
232 SECURITY CODE
PORT SECURITY CODE STATUS
1 000000 DISABLED
2 000000 DISABLED
3 000000 DISABLED
4 000000 DISABLED
5 000000 DISABLED
6 000000 DISABLED
I21900
DEC 14, 2023 9:00 AM
TANK CHART SECURITY
DISABLED
I5BD00
DEC 14, 2023 9:00 AM
CUSTOM ALARM LABELS
DISABLED
I56000
DEC 14, 2023 9:00 AM
MASS/DENSITY
DISABLED
I88101
DEC 14, 2023 9:00 AM
PORT SETTINGS:
COMM BOARD : 1 (EDIM )
RS-232 SECURITY
CODE : DISABLED
I88102
DEC 14, 2023 9:00 AM
PORT SETTINGS:
COMM BOARD : 2 (RS-232)
BAUD RATE : 9600
PARITY : NONE
STOP BIT : 1 STOP
DATA LENGTH: 8 DATA
RS-232 SECURITY
CODE : DISABLED
I88103
DEC 14, 2023 9:00 AM
PORT SETTINGS:
COMM BOARD : 3 (RS-232)
BAUD RATE : 1200
PARITY : ODD
STOP BIT : 1 STOP
DATA LENGTH: 7 DATA
RS-232 SECURITY
CODE : DISABLED
I88104
DEC 14, 2023 9:00 AM
I88105
DEC 14, 2023 9:00 AM
PORT SETTINGS:
COMM BOARD : 5 (S-SAT )
BAUD RATE : 9600
PARITY : NONE
STOP BIT : 2 STOP
DATA LENGTH: 8 DATA
RS-232 SECURITY
CODE : DISABLED
DTR NORMAL STATE: HIGH
I88106
DEC 14, 2023 9:00 AM
I52000
DEC 14, 2023 9:00 AM
RECEIVER AUTO DIAL TYPE & START TIME
RCVR LOCATION LABEL DIAL TYPE START TIME
1 ON DATE FEB 28, 2017 DISABLED
2 ON DATE FEB 28, 2017 DISABLED
3 ON DATE FEB 28, 2017 DISABLED
4 ON DATE FEB 28, 2017 DISABLED
5 ON DATE FEB 28, 2017 DISABLED
6 ON DATE FEB 28, 2017 DISABLED
7 ON DATE FEB 28, 2017 DISABLED
8 WEEKLY FRI 4:41 PM
I60100
DEC 14, 2023 9:00 AM
TANK CONFIGURATION
DEVICE LABEL CONFIGURED
1 SUPREM ON
2 UNLEADED ON
3 OFF
4 OFF
I60200
DEC 14, 2023 9:00 AM
TANK PRODUCT LABEL
TANK PRODUCT LABEL
1 SUPREM
2 UNLEADED
3
4
I60300
DEC 14, 2023 9:00 AM
TANK PRODUCT CODE
TANK PRODUCT LABEL
1 SUPREM 1
2 UNLEADED 2
3 3
4 4
I60900
DEC 14, 2023 9:00 AM
TANK THERMAL COEFFICIENT
TANK PRODUCT LABEL
1 SUPREM 0.000700
2 UNLEADED 0.000700
3 0.000000
4 0.000000
I60700
DEC 14, 2023 9:00 AM
TANK DIAMETER
TANK PRODUCT LABEL INCHES
1 SUPREM 96.00
2 UNLEADED 96.00
3 0.00
4 0.00
I60A00
DEC 14, 2023 9:00 AM
TANK FULL VOLUME
TANK PRODUCT LABEL TANK PROFILE GALLONS 1 SUPREM 1 PT
12000 2 UNLEADED 1 PT 12000 3
1 PT 0 4 1 PT 0
I60400
DEC 14, 2023 9:00 AM
TANK FULL VOLUME
TANK PRODUCT LABEL GALLONS
1 SUPREM 12000
2 UNLEADED 12000
3 0
4 0
I60500
DEC 14, 2023 9:00 AM
TANK 4 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 SUPREM 12000 0 0 0
2 UNLEADED 12000 0 0 0
3 0 0 0 0
4 0 0 0 0
I60600
DEC 14, 2023 9:00 AM
TANK 20 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 SUPREM 12000 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2 UNLEADED 12000 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
3 0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
4 0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
I61500
DEC 14, 2023 9:00 AM
TANK PRODUCT LABEL METER DATA
1 SUPREM NO
2 UNLEADED NO
3 NO
4 NO
I62F00
DEC 14, 2023 9:00 AM
MAG PROBE FLOAT SIZE
TANK PRODUCT LABEL FLOAT SIZE:
1 SUPREM 4.0 IN.
2 UNLEADED 4.0 IN.
I62700
DEC 14, 2023 9:00 AM
TANK HIGH WATER WARNING LIMIT
TANK PRODUCT LABEL INCHES
1 SUPREM 2.0
2 UNLEADED 2.0
I64200
DEC 14, 2023 9:00 AM
WATER ALARM FILTER
TANK PRODUCT LABEL
1 SUPREM LOW
2 UNLEADED LOW
I62400
DEC 14, 2023 9:00 AM
TANK HIGH WATER LEVEL LIMIT
TANK PRODUCT LABEL INCHES
1 SUPREM 3.0
2 UNLEADED 3.0
I62800
DEC 14, 2023 9:00 AM
TANK MAXIMUM VOLUME LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 12000
2 UNLEADED 12000
3 0
4 0
I62300
DEC 14, 2023 9:00 AM
TANK OVERFILL LEVEL LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 10800
2 UNLEADED 10800
3 0
4 0
I62200
DEC 14, 2023 9:00 AM
TANK HIGH PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 11400
2 UNLEADED 11400
3 0
4 0
I62900
DEC 14, 2023 9:00 AM
TANK DELIVERY REQUIRED LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 1200
2 UNLEADED 1200
3 0
4 0
I62100
DEC 14, 2023 9:00 AM
TANK LOW PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 1200
2 UNLEADED 1200
3 0
4 0
I62600
DEC 14, 2023 9:00 AM
TANK LEAK ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 99
2 UNLEADED 99
3 99
4 99
I62500
DEC 14, 2023 9:00 AM
TANK SUDDEN LOSS LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 99
2 UNLEADED 99
3 99
4 99
I60800
DEC 14, 2023 9:00 AM
TANK TILT
TANK PRODUCT LABEL INCHES
1 SUPREM 0.00
2 UNLEADED 0.00
3 0.00
4 0.00
I60B00
DEC 14, 2023 9:00 AM
STICK HEIGHT OFFSET ENABLE STATUS
DISABLED
I60C00
DEC 14, 2023 9:00 AM
TANK STICK HEIGHT OFFSET
TANK PRODUCT LABEL INCHES
1 SUPREM 0.00
2 UNLEADED 0.00
3 0.00
4 0.00
I61200
DEC 14, 2023 9:00 AM
TANK MANIFOLDED PARTNERS
TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS
1 SUPREM NONE NONE
2 UNLEADED NONE NONE
3 NONE NONE
4 NONE NONE
I63600
DEC 14, 2023 9:00 AM
PERIODIC LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 SUPREM 1200
2 UNLEADED 1200
3 0
4 0
I62A00
DEC 14, 2023 9:00 AM
ANNUAL LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 SUPREM 1200
2 UNLEADED 1200
3 0
4 0
I62C00
DEC 14, 2023 9:00 AM
TANK PERIODIC TEST TYPE
TANK PRODUCT LABEL PERIODIC TEST TYPE
1 SUPREM STANDARD
2 UNLEADED STANDARD
3 STANDARD
4 STANDARD
I62D00
DEC 14, 2023 9:00 AM
TANK LEAK TEST FAIL ALARMS
TANK PRODUCT LABEL
1 SUPREM GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
2 UNLEADED GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
3 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
4 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
I63100
DEC 14, 2023 9:00 AM
TANK LEAK TEST AVERAGING
TANK PRODUCT LABEL ANNUAL PERIODIC
1 SUPREM OFF OFF
2 UNLEADED OFF OFF
3 OFF OFF
4 OFF OFF
I63000
DEC 14, 2023 9:00 AM
IN-TANK LEAK TEST NOTIFY
TANK PRODUCT LABEL TANK TEST NOTIFY:
1 SUPREM OFF
2 UNLEADED OFF
3 OFF
4 OFF
I63200
DEC 14, 2023 9:00 AM
TANK TEST SIPHON BREAK
TANK PRODUCT LABEL SIPHON BREAK
1 SUPREM OFF
2 UNLEADED OFF
3 OFF
4 OFF
I61000
DEC 14, 2023 9:00 AM
TANK DELIVERY DELAY
TANK PRODUCT LABEL
1 SUPREM 1
2 UNLEADED 1
3 1
4 1
I63A00
DEC 14, 2023 9:00 AM
LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD
TANK PRODUCT LABEL PUMP THRESHOLD
1 SUPREM 10.00%
2 UNLEADED 10.00%
3 10.00%
4 10.00%
I61100
DEC 14, 2023 9:00 AM
LEAK TEST METHOD
- - - - - - - - - - - -
TEST MONTHLY : ALL TANK
WEEK 1 MON
START TIME : 2:00 AM
TEST RATE :0.20 GAL/HR
DURATION : 2 HOURS
TST EARLY STOP:ENABLED
I61300
DEC 14, 2023 9:00 AM
CSLD PROBABLITY OF DETECTION
I61400
DEC 14, 2023 9:00 AM
CSLD CLIMATE FACTOR
I61600
DEC 14, 2023 9:00 AM
TANK PRODUCT LABEL CAL UPDATE
1 SUPREM IMMEDIATE
2 UNLEADED IMMEDIATE
3 IMMEDIATE
4 IMMEDIATE
I61A00
DEC 14, 2023 9:00 AM
IN-TANK LEAK TEST EARLY STOP
TANK PRODUCT LABEL TST EARLY STOP:
1 SUPREM ENABLED
2 UNLEADED ENABLED
3 ENABLED
4 ENABLED
I61B00
DEC 14, 2023 9:00 AM
IN-TANK LEAK GROSS TEST AUTO-CONFIRM
I61C00
DEC 14, 2023 9:00 AM
CSLD REPORT ONLY
I62B00
DEC 14, 2023 9:00 AM
TANK LAST ANNUAL TEST
TANK PRODUCT LABEL DATE
1 SUPREM ??? 0, 0
2 UNLEADED ??? 0, 0
3 ??? 0, 0
4 ??? 0, 0
I63300
DEC 14, 2023 9:00 AM
LEAK TEST REPORT FORMAT: NORMAL
I63400
DEC 14, 2023 9:00 AM
RECONCILIATION WARNING LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 0
2 UNLEADED 0
3 0
4 0
I63500
DEC 14, 2023 9:00 AM
RECONCILIATION ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 SUPREM 1
2 UNLEADED 1
3 1
4 1
I63900
DEC 14, 2023 9:00 AM
ACCU CHART END SHAPE FACTOR
TANK PRODUCT LABEL
1 SUPREM
END FACTOR: NONE
2 UNLEADED
END FACTOR: NONE
3
END FACTOR: NONE
4
END FACTOR: NONE
I78000
DEC 14, 2023 9:00 AM
I77700
DEC 14, 2023 9:00 AM
I77800
DEC 14, 2023 9:00 AM
I78C00
DEC 14, 2023 9:00 AM
I78300
DEC 14, 2023 9:00 AM
I78F00
DEC 14, 2023 9:00 AM
I78700
DEC 14, 2023 9:00 AM
I70200
DEC 14, 2023 9:00 AM
LIQUID LABEL
DEVICE LABEL
1 DISP 1-2
2 DISP 5-6
3 DISP 3-4
4 DISP 7-8
5 DISP 9-10
6 91 FILL
7 DISP 11-12
8 DISP 3-4
9 87 STP
10 87 ANN
11 87 FILL
12 91 ANN
13 91 STP
14 91 FILL
15 DISP 11-12
16
I70300
DEC 14, 2023 9:00 AM
LIQUID TYPE
SENSOR LOCATION TYPE
1 DISP 1-2 TRI-STATE (SINGLE FLOAT)
2 DISP 5-6 TRI-STATE (SINGLE FLOAT)
3 DISP 3-4 TRI-STATE (SINGLE FLOAT)
4 DISP 7-8 TRI-STATE (SINGLE FLOAT)
5 DISP 9-10 TRI-STATE (SINGLE FLOAT)
6 91 FILL TRI-STATE (SINGLE FLOAT)
7 DISP 11-12 TRI-STATE (SINGLE FLOAT)
8 DISP 3-4 TRI-STATE (SINGLE FLOAT)
9 87 STP TRI-STATE (SINGLE FLOAT)
10 87 ANN TRI-STATE (SINGLE FLOAT)
11 87 FILL TRI-STATE (SINGLE FLOAT)
12 91 ANN TRI-STATE (SINGLE FLOAT)
13 91 STP TRI-STATE (SINGLE FLOAT)
14 91 FILL TRI-STATE (SINGLE FLOAT)
15 DISP 11-12 TRI-STATE (SINGLE FLOAT)
16 TRI-STATE (SINGLE FLOAT)
I70400
DEC 14, 2023 9:00 AM
LIQUID CATEGORY
SENSOR LOCATION CATEGORY
1 DISP 1-2 DISPENSER PAN
2 DISP 5-6 DISPENSER PAN
3 DISP 3-4 DISPENSER PAN
4 DISP 7-8 DISPENSER PAN
5 DISP 9-10 DISPENSER PAN
6 91 FILL PIPING SUMP
7 DISP 11-12 DISPENSER PAN
8 DISP 3-4 DISPENSER PAN
9 87 STP STP SUMP
10 87 ANN ANNULAR SPACE
11 87 FILL PIPING SUMP
12 91 ANN ANNULAR SPACE
13 91 STP STP SUMP
14 91 FILL PIPING SUMP
15 DISP 11-12 DISPENSER PAN
16 OTHER SENSORS
I74200
DEC 14, 2023 9:00 AM
I74300
DEC 14, 2023 9:00 AM
I74400
DEC 14, 2023 9:00 AM
I74700
DEC 14, 2023 9:00 AM
I74800
DEC 14, 2023 9:00 AM
I74900
DEC 14, 2023 9:01 AM
I7BC00
DEC 14, 2023 9:01 AM
I80200
DEC 14, 2023 9:01 AM
I80300
DEC 14, 2023 9:01 AM
I80400
DEC 14, 2023 9:01 AM
I80700
DEC 14, 2023 9:01 AM
RELAY LABEL
DEVICE LABEL
1 POSTITIVE SHUT OFF
2 OVERFILL ALARM
3
4
I80900
DEC 14, 2023 9:01 AM
RELAY ORIENTATION
RELAY DESIGNATION ORIENTATION
1 POSTITIVE SHUT OFF NORMALLY CLOSED
2 OVERFILL ALARM NORMALLY OPEN
3 NORMALLY OPEN
4 NORMALLY OPEN
I80B00
DEC 14, 2023 9:01 AM
RELAY TANK ASSIGNMENT
RELAY DESIGNATION TANK
1 POSTITIVE SHUT OFF 1
2 OVERFILL ALARM NONE
3 NONE
4 NONE
I80A00
DEC 14, 2023 9:01 AM
RELAY TYPE
RELAY DESIGNATION TYPE
1 POSTITIVE SHUT OFF STANDARD
2 OVERFILL ALARM STANDARD
3 STANDARD
4 STANDARD
I80C00
DEC 14, 2023 9:01 AM
I80800
DEC 14, 2023 9:01 AM
RELAY SETUP REPORT
R 1:POSTITIVE SHUT OFF
TYPE:
STANDARD
NORMALLY CLOSED
TANK #: 1
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 7:FUEL ALARM
L 9:FUEL ALARM
L13:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L13:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 7:SHORT ALARM
L 9:SHORT ALARM
L13:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD HOSE ALARMS
h13:GROSS COLLECT FAIL
h14:GROSS COLLECT FAIL
h15:GROSS COLLECT FAIL
h16:GROSS COLLECT FAIL
h17:GROSS COLLECT FAIL
h18:GROSS COLLECT FAIL
h19:GROSS COLLECT FAIL
h20:GROSS COLLECT FAIL
h21:GROSS COLLECT FAIL
h22:GROSS COLLECT FAIL
h23:GROSS COLLECT FAIL
h24:GROSS COLLECT FAIL
h25:GROSS COLLECT FAIL
h26:GROSS COLLECT FAIL
h27:GROSS COLLECT FAIL
h28:GROSS COLLECT FAIL
h29:GROSS COLLECT FAIL
h30:GROSS COLLECT FAIL
h31:GROSS COLLECT FAIL
h32:GROSS COLLECT FAIL
h33:GROSS COLLECT FAIL
h34:GROSS COLLECT FAIL
h35:GROSS COLLECT FAIL
h36:GROSS COLLECT FAIL
h37:GROSS COLLECT FAIL
h38:GROSS COLLECT FAIL
h39:GROSS COLLECT FAIL
h40:GROSS COLLECT FAIL
h41:GROSS COLLECT FAIL
h42:GROSS COLLECT FAIL
h43:GROSS COLLECT FAIL
h44:GROSS COLLECT FAIL
h45:GROSS COLLECT FAIL
h46:GROSS COLLECT FAIL
h47:GROSS COLLECT FAIL
h48:GROSS COLLECT FAIL
h49:GROSS COLLECT FAIL
h50:GROSS COLLECT FAIL
h51:GROSS COLLECT FAIL
h52:GROSS COLLECT FAIL
h53:GROSS COLLECT FAIL
h54:GROSS COLLECT FAIL
h55:GROSS COLLECT FAIL
h56:GROSS COLLECT FAIL
h57:GROSS COLLECT FAIL
h58:GROSS COLLECT FAIL
h59:GROSS COLLECT FAIL
h60:GROSS COLLECT FAIL
h61:GROSS COLLECT FAIL
h62:GROSS COLLECT FAIL
h63:GROSS COLLECT FAIL
h64:GROSS COLLECT FAIL
h65:GROSS COLLECT FAIL
h66:GROSS COLLECT FAIL
h67:GROSS COLLECT FAIL
h68:GROSS COLLECT FAIL
h69:GROSS COLLECT FAIL
h70:GROSS COLLECT FAIL
h71:GROSS COLLECT FAIL
h72:GROSS COLLECT FAIL
h73:GROSS COLLECT FAIL
h74:GROSS COLLECT FAIL
h75:GROSS COLLECT FAIL
h76:GROSS COLLECT FAIL
h77:GROSS COLLECT FAIL
h78:GROSS COLLECT FAIL
h79:GROSS COLLECT FAIL
h80:GROSS COLLECT FAIL
h81:GROSS COLLECT FAIL
h82:GROSS COLLECT FAIL
h83:GROSS COLLECT FAIL
h84:GROSS COLLECT FAIL
h85:GROSS COLLECT FAIL
h86:GROSS COLLECT FAIL
h87:GROSS COLLECT FAIL
h88:GROSS COLLECT FAIL
h89:GROSS COLLECT FAIL
h90:GROSS COLLECT FAIL
h91:GROSS COLLECT FAIL
h92:GROSS COLLECT FAIL
h93:GROSS COLLECT FAIL
h94:GROSS COLLECT FAIL
h95:GROSS COLLECT FAIL
h96:GROSS COLLECT FAIL
h97:GROSS COLLECT FAIL
h98:GROSS COLLECT FAIL
h99:GROSS COLLECT FAIL
h13:DEGRD COLLECT FAIL
h14:DEGRD COLLECT FAIL
h15:DEGRD COLLECT FAIL
h16:DEGRD COLLECT FAIL
h17:DEGRD COLLECT FAIL
h18:DEGRD COLLECT FAIL
h19:DEGRD COLLECT FAIL
h20:DEGRD COLLECT FAIL
h21:DEGRD COLLECT FAIL
h22:DEGRD COLLECT FAIL
h23:DEGRD COLLECT FAIL
h24:DEGRD COLLECT FAIL
h25:DEGRD COLLECT FAIL
h26:DEGRD COLLECT FAIL
h27:DEGRD COLLECT FAIL
h28:DEGRD COLLECT FAIL
h29:DEGRD COLLECT FAIL
h30:DEGRD COLLECT FAIL
h31:DEGRD COLLECT FAIL
h32:DEGRD COLLECT FAIL
h33:DEGRD COLLECT FAIL
h34:DEGRD COLLECT FAIL
h35:DEGRD COLLECT FAIL
h36:DEGRD COLLECT FAIL
h37:DEGRD COLLECT FAIL
h38:DEGRD COLLECT FAIL
h39:DEGRD COLLECT FAIL
h40:DEGRD COLLECT FAIL
h41:DEGRD COLLECT FAIL
h42:DEGRD COLLECT FAIL
h43:DEGRD COLLECT FAIL
h44:DEGRD COLLECT FAIL
h45:DEGRD COLLECT FAIL
h46:DEGRD COLLECT FAIL
h47:DEGRD COLLECT FAIL
h48:DEGRD COLLECT FAIL
h49:DEGRD COLLECT FAIL
h50:DEGRD COLLECT FAIL
h51:DEGRD COLLECT FAIL
h52:DEGRD COLLECT FAIL
h53:DEGRD COLLECT FAIL
h54:DEGRD COLLECT FAIL
h55:DEGRD COLLECT FAIL
h56:DEGRD COLLECT FAIL
h57:DEGRD COLLECT FAIL
h58:DEGRD COLLECT FAIL
h59:DEGRD COLLECT FAIL
h60:DEGRD COLLECT FAIL
h61:DEGRD COLLECT FAIL
h62:DEGRD COLLECT FAIL
h63:DEGRD COLLECT FAIL
h64:DEGRD COLLECT FAIL
h65:DEGRD COLLECT FAIL
h66:DEGRD COLLECT FAIL
h67:DEGRD COLLECT FAIL
h68:DEGRD COLLECT FAIL
h69:DEGRD COLLECT FAIL
h70:DEGRD COLLECT FAIL
h71:DEGRD COLLECT FAIL
h72:DEGRD COLLECT FAIL
h73:DEGRD COLLECT FAIL
h74:DEGRD COLLECT FAIL
h75:DEGRD COLLECT FAIL
h76:DEGRD COLLECT FAIL
h77:DEGRD COLLECT FAIL
h78:DEGRD COLLECT FAIL
h79:DEGRD COLLECT FAIL
h80:DEGRD COLLECT FAIL
h81:DEGRD COLLECT FAIL
h82:DEGRD COLLECT FAIL
h83:DEGRD COLLECT FAIL
h84:DEGRD COLLECT FAIL
h85:DEGRD COLLECT FAIL
h86:DEGRD COLLECT FAIL
h87:DEGRD COLLECT FAIL
h88:DEGRD COLLECT FAIL
h89:DEGRD COLLECT FAIL
h90:DEGRD COLLECT FAIL
h91:DEGRD COLLECT FAIL
h92:DEGRD COLLECT FAIL
h93:DEGRD COLLECT FAIL
h94:DEGRD COLLECT FAIL
h95:DEGRD COLLECT FAIL
h96:DEGRD COLLECT FAIL
h97:DEGRD COLLECT FAIL
h98:DEGRD COLLECT FAIL
h99:DEGRD COLLECT FAIL
h13:FLOW COLLECT FAIL
h14:FLOW COLLECT FAIL
h15:FLOW COLLECT FAIL
h16:FLOW COLLECT FAIL
h17:FLOW COLLECT FAIL
h18:FLOW COLLECT FAIL
h19:FLOW COLLECT FAIL
h20:FLOW COLLECT FAIL
h21:FLOW COLLECT FAIL
h22:FLOW COLLECT FAIL
h23:FLOW COLLECT FAIL
h24:FLOW COLLECT FAIL
h25:FLOW COLLECT FAIL
h26:FLOW COLLECT FAIL
h27:FLOW COLLECT FAIL
h28:FLOW COLLECT FAIL
h29:FLOW COLLECT FAIL
h30:FLOW COLLECT FAIL
h31:FLOW COLLECT FAIL
h32:FLOW COLLECT FAIL
h33:FLOW COLLECT FAIL
h34:FLOW COLLECT FAIL
h35:FLOW COLLECT FAIL
h36:FLOW COLLECT FAIL
h37:FLOW COLLECT FAIL
h38:FLOW COLLECT FAIL
h39:FLOW COLLECT FAIL
h40:FLOW COLLECT FAIL
h41:FLOW COLLECT FAIL
h42:FLOW COLLECT FAIL
h43:FLOW COLLECT FAIL
h44:FLOW COLLECT FAIL
h45:FLOW COLLECT FAIL
h46:FLOW COLLECT FAIL
h47:FLOW COLLECT FAIL
h48:FLOW COLLECT FAIL
h49:FLOW COLLECT FAIL
h50:FLOW COLLECT FAIL
h51:FLOW COLLECT FAIL
h52:FLOW COLLECT FAIL
h53:FLOW COLLECT FAIL
h54:FLOW COLLECT FAIL
h55:FLOW COLLECT FAIL
h56:FLOW COLLECT FAIL
h57:FLOW COLLECT FAIL
h58:FLOW COLLECT FAIL
h59:FLOW COLLECT FAIL
h60:FLOW COLLECT FAIL
h61:FLOW COLLECT FAIL
h62:FLOW COLLECT FAIL
h63:FLOW COLLECT FAIL
h64:FLOW COLLECT FAIL
h65:FLOW COLLECT FAIL
h66:FLOW COLLECT FAIL
h67:FLOW COLLECT FAIL
h68:FLOW COLLECT FAIL
h69:FLOW COLLECT FAIL
h70:FLOW COLLECT FAIL
h71:FLOW COLLECT FAIL
h72:FLOW COLLECT FAIL
h73:FLOW COLLECT FAIL
h74:FLOW COLLECT FAIL
h75:FLOW COLLECT FAIL
h76:FLOW COLLECT FAIL
h77:FLOW COLLECT FAIL
h78:FLOW COLLECT FAIL
h79:FLOW COLLECT FAIL
h80:FLOW COLLECT FAIL
h81:FLOW COLLECT FAIL
h82:FLOW COLLECT FAIL
h83:FLOW COLLECT FAIL
h84:FLOW COLLECT FAIL
h85:FLOW COLLECT FAIL
h86:FLOW COLLECT FAIL
h87:FLOW COLLECT FAIL
h88:FLOW COLLECT FAIL
h89:FLOW COLLECT FAIL
h90:FLOW COLLECT FAIL
h91:FLOW COLLECT FAIL
h92:FLOW COLLECT FAIL
h93:FLOW COLLECT FAIL
h94:FLOW COLLECT FAIL
h95:FLOW COLLECT FAIL
h96:FLOW COLLECT FAIL
h97:FLOW COLLECT FAIL
h98:FLOW COLLECT FAIL
h99:FLOW COLLECT FAIL
R 2:OVERFILL ALARM
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
IN-TANK ALARMS
ALL:OVERFILL ALARM
ALL:HIGH PRODUCT ALARM
ALL:MAX PRODUCT ALARM
R 3:
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R 4:
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
I79000
DEC 14, 2023 9:01 AM
EDIM:1 VR:349867-001-C TD:16.05.27.07.44
I79100
DEC 14, 2023 9:01 AM
I72300
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
SMARTSENSOR ASSIGNMENT
DEVICE LABEL CATEGORY
01 FM 1-2 AIR FLOW METER
02 UNKNOWN
03 FM 5-6 AIR FLOW METER
04 FM 7-8 AIR FLOW METER
05 FM 9-10 AIR FLOW METER
06 FM 11-12 AIR FLOW METER
07 FM 3-4 AIR FLOW METER
08 PS 1-2 VAPOR PRESSURE
09 UNKNOWN
10 UNKNOWN
11 UNKNOWN
12 UNKNOWN
13 UNKNOWN
14 UNKNOWN
15 UNKNOWN
16 UNKNOWN
17 UNKNOWN
18 UNKNOWN
19 UNKNOWN
20 UNKNOWN
21 UNKNOWN
22 UNKNOWN
23 UNKNOWN
24 UNKNOWN
25 UNKNOWN
26 UNKNOWN
27 UNKNOWN
28 UNKNOWN
29 UNKNOWN
30 UNKNOWN
31 UNKNOWN
32 UNKNOWN
33 UNKNOWN
34 UNKNOWN
35 UNKNOWN
36 UNKNOWN
37 UNKNOWN
38 UNKNOWN
39 UNKNOWN
40 UNKNOWN
IV4E00
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
EVR/ISD SETUP
TYPE: BALANCE
IV4F00
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
NOZZLE A/L RANGE
A/L RATIO: 0.95 - 1.15
IV4000
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
VAPOR PROCESSOR TYPE
NONE
IV4700
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
ASSESSMENT TIME
START TIME: 10:00 AM
TIME DELAY MINUTES: 1
IV5200
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
ACCEPT HIGH ORVR: YES
IV4A00
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
ISD HOSE TABLE
HOSE FP FP AFM REL HOSE
ID ID LABEL ID ID LABEL
01 01 01 01 UU BLEND3
02 02 02 01 UU BLEND3
03 03 03 06 UU BLEND3
04 04 04 06 UU BLEND3
05 05 05 02 UU BLEND3
06 06 06 02 UU BLEND3
07 07 07 03 UU BLEND3
08 08 08 03 UU BLEND3
09 09 09 04 UU BLEND3
10 16 10 04 UU BLEND3
11 17 11 05 UU BLEND3
12 18 12 05 UU BLEND3
IV4B00
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
PRODUCT/HOSE MAP TABLE
FP AFID M1/H1 M2/H2 M3/H3 M4/H4
01 01 02/01 09/01 01/01 xx/xx
02 01 02/02 09/02 01/02 xx/xx
03 06 02/03 09/03 01/03 xx/xx
04 06 02/04 09/04 01/04 xx/xx
05 02 02/05 09/05 01/05 xx/xx
06 02 02/06 09/06 01/06 xx/xx
07 03 02/07 09/07 01/07 xx/xx
08 03 02/08 09/08 01/08 xx/xx
09 04 02/09 09/09 01/09 xx/xx
16 04 02/10 09/10 01/10 xx/xx
17 05 02/11 09/11 01/11 xx/xx
18 05 02/12 09/12 01/12 xx/xx
IV4900
DEC 14, 2023 9:01 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
LABEL TABLE
ID LABEL
01 UNASSIGNED
02 BLEND3
03 REGULAR
04 MID GRADE
05 PREMIUM
06 GOLD
07 BRONZE
08 SILVER
09 BLEND2
10 BLEND4
IV1000
DEC 14, 2023 9:01 AM
ISD VERSION: 01.05
SamCo White Lane Pre Alarm History
Responses Received:
I10200
DEC 14, 2023 9:02 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 8SMARTSENSOR BD 39616 39595
2 4 PROBE / G.T. 163711 163619
3 INTERSTITIAL BD 201522 201495
4 INTERSTITIAL BD 201289 201401
5 UNUSED 9922524 9845654
6 UNUSED 9907690 9831796
7 UNUSED 9915587 9833925
8 UNUSED 9907646 9836552
9 UNUSED 9907173 9834336
10 RELAY BOARD 14999 15044
11 UNUSED 9912594 9840223
12 UNUSED 9902690 9848420
13 UNUSED 9902021 9837143
14 UNUSED 9903850 9836985
15 UNUSED 9899656 9841287
16 UNUSED 9908935 9837324
COMM 1 ELEC DISP INT. 101163 101306
COMM 2 RS232 SERIAL BD 15022 14999
COMM 3 RS232 SERIAL BD 15044 15044
COMM 4 UNUSED 9906995 9842283
COMM 5 SERIAL SAT BD 480692 481403
COMM 6 UNUSED 9915493 9833702
I90200
DEC 14, 2023 9:02 AM
SOFTWARE REVISION LEVEL
VERSION 336.01
SOFTWARE# 346336-100-B
CREATED - 20.04.26.20.30
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
ISD/APM
I11100
DEC 14, 2023 9:02 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
L14 PIPE 91 FILL FUEL ALARM CLEAR 12-13-23 9:08AM
L14 PIPE 91 FILL FUEL ALARM ALARM 12-10-23 9:44AM
OTHER ISD VAPOR LEAK FAIL CLEAR 9-27-23 7:35AM
OTHER ISD VAPOR LEAK FAIL ALARM 9-26-23 10:04AM
E 1 OTHER COMMUNICATION ALARM CLEAR 8-25-23 10:50AM
E 1 OTHER COMMUNICATION ALARM ALARM 8-25-23 10:06AM
L11 PIPE 87 FILL FUEL ALARM CLEAR 8-21-23 11:01AM
L11 PIPE 87 FILL FUEL ALARM ALARM 8-20-23 7:20PM
D 8 OTHER AUTODIAL FAILURE CLEAR 8-11-23 4:45PM
D 8 OTHER AUTODIAL FAILURE ALARM 8-04-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 8-04-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 7-28-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-28-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 7-22-23 10:26AM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-22-23 10:26AM
D 8 OTHER AUTODIAL FAILURE ALARM 7-21-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-21-23 5:06PM
h 4 OTHER FP4: BLEND3 FLOW COLLECT FAIL CLEAR 7-21-23 10:00AM
D 8 OTHER AUTODIAL FAILURE ALARM 7-20-23 10:29AM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-20-23 10:29AM
h 4 OTHER FP4: BLEND3 FLOW COLLECT FAIL ALARM 7-20-23 10:04AM
D 8 OTHER AUTODIAL FAILURE ALARM 7-19-23 10:29AM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-19-23 10:29AM
D 8 OTHER AUTODIAL FAILURE ALARM 7-16-23 3:17AM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-16-23 3:17AM
D 8 OTHER AUTODIAL FAILURE ALARM 7-14-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-14-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 7-14-23 3:13AM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-14-23 3:13AM
T 2 TANK UNLEADED OVERFILL ALARM CLEAR 7-14-23 2:51AM
T 2 TANK UNLEADED OVERFILL ALARM ALARM 7-14-23 2:48AM
D 8 OTHER AUTODIAL FAILURE ALARM 7-07-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 7-07-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 6-30-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 6-30-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 6-23-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 6-23-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 6-16-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 6-16-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 6-09-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 6-09-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 6-02-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 6-02-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 5-26-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 5-26-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 5-19-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 5-19-23 5:06PM
D 8 OTHER AUTODIAL FAILURE ALARM 5-12-23 5:06PM
D 8 OTHER AUTODIAL FAILURE CLEAR 5-05-23 4:43PM
D 8 OTHER AUTODIAL FAILURE ALARM 5-02-23 4:53PM
I11200
DEC 14, 2023 9:02 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
OTHER ISD DEGRD PRES WARN CLEAR 11-05-23 6:16PM
OTHER ISD DEGRD PRES WARN ALARM 11-05-23 10:04AM
OTHER ISD GROSS PRES WARN CLEAR 10-18-23 10:00AM
OTHER ISD GROSS PRES WARN ALARM 10-17-23 10:04AM
OTHER ISD GROSS PRES WARN CLEAR 10-10-23 10:16AM
h 8 OTHER FP8: BLEND3 FLOW COLLECT WARN CLEAR 10-10-23 10:00AM
h 8 OTHER FP8: BLEND3 FLOW COLLECT WARN ALARM 10-09-23 10:04AM
h 4 OTHER FP4: BLEND3 FLOW COLLECT WARN CLEAR 10-09-23 10:00AM
h 4 OTHER FP4: BLEND3 FLOW COLLECT WARN ALARM 10-08-23 10:04AM
OTHER ISD GROSS PRES WARN ALARM 10-04-23 10:04AM
SYSTEM PRINTER ERROR CLEAR 9-28-23 6:58AM
SYSTEM PAPER OUT CLEAR 9-28-23 6:58AM
SYSTEM PAPER OUT ALARM 9-28-23 6:58AM
SYSTEM PRINTER ERROR ALARM 9-28-23 6:58AM
SYSTEM PRINTER ERROR CLEAR 9-28-23 6:57AM
SYSTEM PRINTER ERROR ALARM 9-28-23 6:57AM
SYSTEM PRINTER ERROR CLEAR 9-28-23 6:57AM
SYSTEM PAPER OUT CLEAR 9-28-23 6:57AM
SYSTEM PRINTER ERROR ALARM 9-28-23 6:56AM
SYSTEM PAPER OUT ALARM 9-28-23 6:56AM
OTHER ISD VAPOR LEAK WARN CLEAR 9-26-23 10:04AM
OTHER ISD VAPOR LEAK WARN ALARM 9-19-23 10:05AM
SYSTEM PRINTER ERROR CLEAR 9-04-23 9:37AM
SYSTEM PAPER OUT CLEAR 9-04-23 9:37AM
SYSTEM PAPER OUT ALARM 9-04-23 9:37AM
SYSTEM PRINTER ERROR ALARM 9-04-23 9:20AM
SYSTEM PRINTER ERROR CLEAR 9-01-23 7:09PM
SYSTEM PAPER OUT CLEAR 9-01-23 7:09PM
SYSTEM PRINTER ERROR ALARM 9-01-23 7:08PM
SYSTEM PAPER OUT ALARM 9-01-23 7:08PM
SYSTEM PRINTER ERROR CLEAR 9-01-23 7:08PM
SYSTEM PAPER OUT CLEAR 9-01-23 7:08PM
SYSTEM PRINTER ERROR ALARM 9-01-23 7:07PM
SYSTEM PAPER OUT ALARM 9-01-23 7:07PM
SYSTEM PRINTER ERROR CLEAR 8-09-23 10:22PM
SYSTEM PAPER OUT CLEAR 8-09-23 10:22PM
SYSTEM PRINTER ERROR ALARM 8-09-23 10:22PM
SYSTEM PAPER OUT ALARM 8-09-23 10:22PM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PRINTER ERROR ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT CLEAR 8-09-23 8:10AM
SYSTEM PRINTER ERROR ALARM 8-09-23 8:10AM
SYSTEM PAPER OUT ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT CLEAR 8-09-23 8:10AM
I20600
DEC 14, 2023 9:02 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
TANK ALARM HISTORY
TANK 1 SUPREM
OVERFILL ALARM DEC 9, 2021 10:35 AM
LOW PRODUCT ALARM DEC 9, 2021 10:28 AM
INVALID FUEL LEVEL DEC 9, 2021 10:28 AM
PROBE OUT DEC 9, 2021 10:38 AM
DEC 9, 2021 10:29 AM
DELIVERY NEEDED DEC 9, 2021 10:28 AM
LOW TEMP WARNING DEC 9, 2021 10:38 AM
TANK 2 UNLEADED
OVERFILL ALARM JUL 14, 2023 2:48 AM
MAR 15, 2023 12:24 AM
JAN 2, 2023 3:06 AM
LOW PRODUCT ALARM DEC 9, 2021 10:57 AM
DEC 9, 2021 10:41 AM
INVALID FUEL LEVEL DEC 9, 2021 10:57 AM
PROBE OUT DEC 9, 2021 10:56 AM
DEC 9, 2021 10:40 AM
DELIVERY NEEDED DEC 9, 2021 10:57 AM
DEC 9, 2021 10:41 AM
TANK 5
TANK 6
TANK 7
TANK 8
TANK 9
TANK 10
TANK 11
TANK 12
TANK 13
TANK 14
TANK 15
TANK 16
I38200
DEC 14, 2023 9:02 AM
I30200
DEC 14, 2023 9:02 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP 1-2
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:02 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
2 DISP 5-6
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:03 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
3 DISP 3-4
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:02 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
4 DISP 7-8
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:04 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
5 DISP 9-10
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:04 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
7 DISP 11-12
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:05 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
9 87 STP
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:01 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
10 87 ANN
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 8:53 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
11 87 FILL
AUG 20, 2023 7:20 PM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 8:50 AM FUEL ALARM
12 91 ANN
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 8:55 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
13 91 STP
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
DEC 8, 2022 9:01 AM FUEL ALARM
DEC 9, 2021 9:15 AM SENSOR OUT ALARM
14 91 FILL
DEC 10, 2023 9:44 AM FUEL ALARM
FEB 25, 2023 2:22 AM FUEL ALARM
DEC 8, 2022 12:51 PM FUEL ALARM
I31600
DEC 14, 2023 9:03 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION
1 FM 1-2
3 FM 5-6
4 FM 7-8
5 FM 9-10
6 FM 11-12
7 FM 3-4
8 PS 1-2
I40200
DEC 14, 2023 9:03 AM
I40300
DEC 14, 2023 9:03 AM
I34200
DEC 14, 2023 9:03 AM
I34700
DEC 14, 2023 9:03 AM
IV0100
DEC 14, 2023 9:03 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
ISD ALARM STATUS REPORT
EVR TYPE: BALANCE
ISD TYPE: 01.05
VAPOR PROCESSOR TYPE: NONE
OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS
EVR VAPOR CONTAINMENT :PASS
ISD MONITOR UP-TIME :100%
EVR/ISD PASS TIME :100%
WARNING ALARMS
DATE TIME DESCRIPTION READING VALUE
23-12-13 10:04:08
23-12-12 10:04:09
23-12-11 10:04:39
23-12-10 10:03:32
23-11-05 10:04:59 CONTAINMENT PRESSURE DEGRADATIONMONTHLY 75% 0.30
23-10-17 10:04:51 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.69
23-10-10 10:04:39 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.58
23-10-09 10:04:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.58
23-10-09 10:04:37 FLOW PERFORMANCE HOSE BLOCKAGE FP 8 BLEND3 0.57
23-10-08 10:04:29 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.58
FAILURE ALARMS
DATE TIME DESCRIPTION READING VALUE
23-09-26 10:04:42 VAPOR CONTAINMENT LEAKAGE GROSS FAIL
23-07-20 10:04:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 4 BLEND3
23-04-19 10:03:16 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3
22-12-21 10:04:43 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 84.61
22-11-29 10:02:05 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 292.13
22-10-24 10:01:56 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 204.97
22-10-23 10:02:11 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 151.29
21-08-11 10:05:48 FLOW PERFORMANCE HOSE BLOCKAGE FP 9 BLEND3
21-07-06 10:02:35 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD
21-07-06 10:02:35 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD
SHUTDOWN & MISCELLANEOUS EVENTS
DATE TIME DESCRIPTION ACTION/NAME
23-11-20 10:04:04 READINESS ISD:PP EVR:PP ISD & EVR READY
23-11-19 10:04:13 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-18 10:04:28 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-17 10:04:36 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-16 10:04:37 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-16 00:34:08 READINESS ISD:PP EVR:NN EVR READINESS PENDING
23-11-16 00:34:08 ISD STARTUP
23-11-16 00:33:57 ISD SHUTDOWN
23-11-15 15:37:54 READINESS ISD:PP EVR:NN EVR READINESS PENDING
23-11-15 15:37:54 ISD STARTUP
Post Alarm History
Responses Received:
I10200
DEC 14, 2023 11:13 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 8SMARTSENSOR BD 39616 39566
2 4 PROBE / G.T. 163711 163488
3 INTERSTITIAL BD 201522 201265
4 INTERSTITIAL BD 201289 201148
5 UNUSED 9922524 9849024
6 UNUSED 9907690 9849069
7 UNUSED 9915587 9852272
8 UNUSED 9907646 9843204
9 UNUSED 9907173 9835067
10 RELAY BOARD 14999 15022
11 UNUSED 9912594 9839331
12 UNUSED 9902690 9822999
13 UNUSED 9902021 9841609
14 UNUSED 9903850 9847519
15 UNUSED 9899656 9837549
16 UNUSED 9908935 9849098
COMM 1 ELEC DISP INT. 101163 101138
COMM 2 RS232 SERIAL BD 15022 15022
COMM 3 RS232 SERIAL BD 15044 15044
COMM 4 UNUSED 9906995 9846053
COMM 5 SERIAL SAT BD 480692 480584
COMM 6 UNUSED 9915493 9852211
I90200
DEC 14, 2023 11:13 AM
SOFTWARE REVISION LEVEL
VERSION 336.01
SOFTWARE# 346336-100-B
CREATED - 20.04.26.20.30
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
ISD/APM
I11100
DEC 14, 2023 11:13 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
L11 PIPE 87 FILL SENSOR OUT ALARM CLEAR 12-14-23 9:49AM
L14 PIPE 91 FILL SENSOR OUT ALARM CLEAR 12-14-23 9:49AM
L 9 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 12-14-23 9:49AM
L13 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 12-14-23 9:49AM
L12 ANNULAR 91 ANN SENSOR OUT ALARM CLEAR 12-14-23 9:49AM
L10 ANNULAR 87 ANN SENSOR OUT ALARM CLEAR 12-14-23 9:49AM
L 3 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 12-14-23 9:48AM
L 2 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 12-14-23 9:48AM
L 7 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 12-14-23 9:48AM
L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 12-14-23 9:48AM
L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 12-14-23 9:48AM
L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 12-14-23 9:48AM
L 7 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L12 ANNULAR 91 ANN SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L 3 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L11 PIPE 87 FILL SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L10 ANNULAR 87 ANN SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L 2 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L14 PIPE 91 FILL SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L 9 STP SUMP 87 STP SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L13 STP SUMP 91 STP SENSOR OUT ALARM ALARM 12-14-23 9:48AM
L10 ANNULAR 87 ANN FUEL ALARM CLEAR 12-14-23 9:41AM
L10 ANNULAR 87 ANN FUEL ALARM ALARM 12-14-23 9:40AM
L12 ANNULAR 91 ANN FUEL ALARM CLEAR 12-14-23 9:37AM
L12 ANNULAR 91 ANN FUEL ALARM ALARM 12-14-23 9:37AM
L 7 DISP PAN DISP 11-12 FUEL ALARM CLEAR 12-14-23 9:35AM
L 7 DISP PAN DISP 11-12 FUEL ALARM ALARM 12-14-23 9:35AM
L 5 DISP PAN DISP 9-10 FUEL ALARM CLEAR 12-14-23 9:35AM
L 5 DISP PAN DISP 9-10 FUEL ALARM ALARM 12-14-23 9:34AM
L 4 DISP PAN DISP 7-8 FUEL ALARM CLEAR 12-14-23 9:34AM
L 4 DISP PAN DISP 7-8 FUEL ALARM ALARM 12-14-23 9:34AM
L 2 DISP PAN DISP 5-6 FUEL ALARM CLEAR 12-14-23 9:33AM
L 2 DISP PAN DISP 5-6 FUEL ALARM ALARM 12-14-23 9:33AM
L 3 DISP PAN DISP 3-4 FUEL ALARM CLEAR 12-14-23 9:33AM
L 3 DISP PAN DISP 3-4 FUEL ALARM ALARM 12-14-23 9:33AM
L 1 DISP PAN DISP 1-2 FUEL ALARM CLEAR 12-14-23 9:32AM
L 1 DISP PAN DISP 1-2 FUEL ALARM ALARM 12-14-23 9:32AM
L11 PIPE 87 FILL FUEL ALARM CLEAR 12-14-23 9:31AM
L11 PIPE 87 FILL FUEL ALARM ALARM 12-14-23 9:31AM
L14 PIPE 91 FILL FUEL ALARM CLEAR 12-14-23 9:30AM
L14 PIPE 91 FILL FUEL ALARM ALARM 12-14-23 9:30AM
L13 STP SUMP 91 STP FUEL ALARM CLEAR 12-14-23 9:30AM
L13 STP SUMP 91 STP FUEL ALARM ALARM 12-14-23 9:30AM
L 9 STP SUMP 87 STP FUEL ALARM CLEAR 12-14-23 9:29AM
L 9 STP SUMP 87 STP FUEL ALARM ALARM 12-14-23 9:29AM
L14 PIPE 91 FILL FUEL ALARM CLEAR 12-13-23 9:08AM
L14 PIPE 91 FILL FUEL ALARM ALARM 12-10-23 9:44AM
I11200
DEC 14, 2023 11:13 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
OTHER ISD DEGRD PRES WARN CLEAR 11-05-23 6:16PM
OTHER ISD DEGRD PRES WARN ALARM 11-05-23 10:04AM
OTHER ISD GROSS PRES WARN CLEAR 10-18-23 10:00AM
OTHER ISD GROSS PRES WARN ALARM 10-17-23 10:04AM
OTHER ISD GROSS PRES WARN CLEAR 10-10-23 10:16AM
h 8 OTHER FP8: BLEND3 FLOW COLLECT WARN CLEAR 10-10-23 10:00AM
h 8 OTHER FP8: BLEND3 FLOW COLLECT WARN ALARM 10-09-23 10:04AM
h 4 OTHER FP4: BLEND3 FLOW COLLECT WARN CLEAR 10-09-23 10:00AM
h 4 OTHER FP4: BLEND3 FLOW COLLECT WARN ALARM 10-08-23 10:04AM
OTHER ISD GROSS PRES WARN ALARM 10-04-23 10:04AM
SYSTEM PRINTER ERROR CLEAR 9-28-23 6:58AM
SYSTEM PAPER OUT CLEAR 9-28-23 6:58AM
SYSTEM PAPER OUT ALARM 9-28-23 6:58AM
SYSTEM PRINTER ERROR ALARM 9-28-23 6:58AM
SYSTEM PRINTER ERROR CLEAR 9-28-23 6:57AM
SYSTEM PRINTER ERROR ALARM 9-28-23 6:57AM
SYSTEM PRINTER ERROR CLEAR 9-28-23 6:57AM
SYSTEM PAPER OUT CLEAR 9-28-23 6:57AM
SYSTEM PRINTER ERROR ALARM 9-28-23 6:56AM
SYSTEM PAPER OUT ALARM 9-28-23 6:56AM
OTHER ISD VAPOR LEAK WARN CLEAR 9-26-23 10:04AM
OTHER ISD VAPOR LEAK WARN ALARM 9-19-23 10:05AM
SYSTEM PRINTER ERROR CLEAR 9-04-23 9:37AM
SYSTEM PAPER OUT CLEAR 9-04-23 9:37AM
SYSTEM PAPER OUT ALARM 9-04-23 9:37AM
SYSTEM PRINTER ERROR ALARM 9-04-23 9:20AM
SYSTEM PRINTER ERROR CLEAR 9-01-23 7:09PM
SYSTEM PAPER OUT CLEAR 9-01-23 7:09PM
SYSTEM PRINTER ERROR ALARM 9-01-23 7:08PM
SYSTEM PAPER OUT ALARM 9-01-23 7:08PM
SYSTEM PRINTER ERROR CLEAR 9-01-23 7:08PM
SYSTEM PAPER OUT CLEAR 9-01-23 7:08PM
SYSTEM PRINTER ERROR ALARM 9-01-23 7:07PM
SYSTEM PAPER OUT ALARM 9-01-23 7:07PM
SYSTEM PRINTER ERROR CLEAR 8-09-23 10:22PM
SYSTEM PAPER OUT CLEAR 8-09-23 10:22PM
SYSTEM PRINTER ERROR ALARM 8-09-23 10:22PM
SYSTEM PAPER OUT ALARM 8-09-23 10:22PM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PRINTER ERROR ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT CLEAR 8-09-23 8:10AM
SYSTEM PRINTER ERROR ALARM 8-09-23 8:10AM
SYSTEM PAPER OUT ALARM 8-09-23 8:10AM
SYSTEM PRINTER ERROR CLEAR 8-09-23 8:10AM
SYSTEM PAPER OUT CLEAR 8-09-23 8:10AM
I20600
DEC 14, 2023 11:14 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
TANK ALARM HISTORY
TANK 1 SUPREM
OVERFILL ALARM DEC 9, 2021 10:35 AM
LOW PRODUCT ALARM DEC 9, 2021 10:28 AM
INVALID FUEL LEVEL DEC 9, 2021 10:28 AM
PROBE OUT DEC 9, 2021 10:38 AM
DEC 9, 2021 10:29 AM
DELIVERY NEEDED DEC 9, 2021 10:28 AM
LOW TEMP WARNING DEC 9, 2021 10:38 AM
TANK 2 UNLEADED
OVERFILL ALARM JUL 14, 2023 2:48 AM
MAR 15, 2023 12:24 AM
JAN 2, 2023 3:06 AM
LOW PRODUCT ALARM DEC 9, 2021 10:57 AM
DEC 9, 2021 10:41 AM
INVALID FUEL LEVEL DEC 9, 2021 10:57 AM
PROBE OUT DEC 9, 2021 10:56 AM
DEC 9, 2021 10:40 AM
DELIVERY NEEDED DEC 9, 2021 10:57 AM
DEC 9, 2021 10:41 AM
TANK 5
TANK 6
TANK 7
TANK 8
TANK 9
TANK 10
TANK 11
TANK 12
TANK 13
TANK 14
TANK 15
TANK 16
I38200
DEC 14, 2023 11:14 AM
I30200
DEC 14, 2023 11:14 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP 1-2
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:32 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
2 DISP 5-6
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:33 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
3 DISP 3-4
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:33 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
4 DISP 7-8
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:34 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
5 DISP 9-10
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:34 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
7 DISP 11-12
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:35 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
9 87 STP
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:29 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
10 87 ANN
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:40 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
11 87 FILL
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:31 AM FUEL ALARM
AUG 20, 2023 7:20 PM FUEL ALARM
12 91 ANN
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:37 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
13 91 STP
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:30 AM FUEL ALARM
DEC 8, 2022 9:11 AM SENSOR OUT ALARM
14 91 FILL
DEC 14, 2023 9:48 AM SENSOR OUT ALARM
DEC 14, 2023 9:30 AM FUEL ALARM
DEC 10, 2023 9:44 AM FUEL ALARM
I31600
DEC 14, 2023 11:14 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION
1 FM 1-2
3 FM 5-6
4 FM 7-8
5 FM 9-10
6 FM 11-12
7 FM 3-4
8 PS 1-2
I40200
DEC 14, 2023 11:14 AM
I40300
DEC 14, 2023 11:14 AM
I34200
DEC 14, 2023 11:14 AM
I34700
DEC 14, 2023 11:14 AM
IV0100
DEC 14, 2023 11:14 AM
208402 CHVRNSAMCO 2
3300 WHITE LN.
BAKERSFIELD,CA 93309
661-827 0487
ISD ALARM STATUS REPORT
EVR TYPE: BALANCE
ISD TYPE: 01.05
VAPOR PROCESSOR TYPE: NONE
OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS
EVR VAPOR CONTAINMENT :PASS
ISD MONITOR UP-TIME : 99%
EVR/ISD PASS TIME :100%
WARNING ALARMS
DATE TIME DESCRIPTION READING VALUE
23-12-13 10:04:08
23-12-12 10:04:09
23-12-11 10:04:39
23-12-10 10:03:32
23-11-05 10:04:59 CONTAINMENT PRESSURE DEGRADATIONMONTHLY 75% 0.30
23-10-17 10:04:51 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.69
23-10-10 10:04:39 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.58
23-10-09 10:04:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.58
23-10-09 10:04:37 FLOW PERFORMANCE HOSE BLOCKAGE FP 8 BLEND3 0.57
23-10-08 10:04:29 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.58
FAILURE ALARMS
DATE TIME DESCRIPTION READING VALUE
23-09-26 10:04:42 VAPOR CONTAINMENT LEAKAGE GROSS FAIL
23-07-20 10:04:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 4 BLEND3
23-04-19 10:03:16 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3
22-12-21 10:04:43 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 84.61
22-11-29 10:02:05 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 292.13
22-10-24 10:01:56 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 204.97
22-10-23 10:02:11 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 151.29
21-08-11 10:05:48 FLOW PERFORMANCE HOSE BLOCKAGE FP 9 BLEND3
21-07-06 10:02:35 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD
21-07-06 10:02:35 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD
SHUTDOWN & MISCELLANEOUS EVENTS
DATE TIME DESCRIPTION ACTION/NAME
23-12-14 10:04:41 READINESS ISD:PP EVR:PP ISD & EVR READY
23-12-14 09:49:35 READINESS ISD:PP EVR:NN EVR READINESS PENDING
23-12-14 09:49:35 ISD STARTUP
23-12-14 09:49:27 ISD SHUTDOWN
23-11-20 10:04:04 READINESS ISD:PP EVR:PP ISD & EVR READY
23-11-19 10:04:13 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-18 10:04:28 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-17 10:04:36 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-16 10:04:37 READINESS ISD:PP EVR:NP EVR READINESS PENDING
23-11-16 00:34:08 READINESS ISD:PP EVR:NN EVR READINESS PENDING