HomeMy WebLinkAboutORD NO 3552Ordinance No. 3 5 $ 2 AN ORDINANCE AMENDING CHAPTER 15.40 OF THE BAKERSFIELD MUNICIPAL CODE RELATING TO UNREINFORCED MASONRY BUILDINGS. BE IT ORDAINED by the Council of the City of Bakersfield as follows: SECTION 1. Chapter 15.40 of the Bakersfield Municipal Code is hereby amended to read as follows: Chapter 15.40 EARTHQUAKE HAZARD REDUCTION IN EXISTING UNREINFORCED MASONRY HEARING WALL BUILDINGS Sections: 15.40.010 15.40.020 15.40.030 15.40.040 15.40.050 15.40.060 15.40.070 15.40.080 Purpose. Scope. Definitions. Material requirements. Quality control. Allowable design values. Detailed systems design requirements. Tables and standards. 15.40.010 Purpose. The purpose of this Chapter is to promote public safety, health and welfare by reducing the risk of death or injury that may result from the effects of earthquakes on unreinforced masonry buildings. The provisions of this Chapter establish minimum standards for structural seismic resistance primarily to reduce the risk of death or injury, but cannot prevent loss of life or injury or prevent earthquake damage to an existing building even though it complies with these standards. ORI(~INAL 15.40.020 Scope. The provisions of these requirements shall apply to all buildings having unreinforced masonry bearing walls as defined herein. It is recognized that strengthening was done to many unreinforced masonry buildings following the 1952 Kern County earthquake. The Engineer or Architect retained by the building owner and the City Building Official shall give full consideration to any strengthening done when analyzing the existing condition of the building as required by this Chapter. Where strengthening was done which may not fully comply with the provisions of this Chapter, approval may be granted by the City Building Official if the building's condition complies with the intent of this Chapter. Nothing in this Chapter shall prevent the building owner, his Architect or Engineer from employing accepted alternative methods to prove the minimum seismic safety of a building. In the event an alternative method is employed by the building owner, his Architect or Engineer which is not accepted by the City Building Official, the building owner shall have the right to appeal that decision to the Board of Building Appeals. 15.40.030 Definitions. For the purpose of this Chapter, certain terms are defined as follows: (a) "CROSS WALLS:" are interior walls of masonry or wood stud construction. In order to be considered as a cross wall within the intent of this Chapter, cross walls shall be not more than 40 feet apart in each story, and shall be full story height between diaphragms. Existing cross walls shall be a minimum length of one and one-half times the story height. Existing wood frame cross walls shall be sheathed with one of the following: wood lath and plaster, 1/2 inch thick gypsum wallboard two sides, or solid one inch nominal thickness straight or diagonal wood board sheathing. New cross walls shall have a rational shear path to the ground, and shall be constructed of materials that are assigned allowable shear values in Chapter 25 or Chapter 47 of the Uniform Building Code, and shall have a total shear capacity equivalent to that of a wall 1 1/2 times the story height that is sheathed with a material that has an allowable shear value of 150 pounds per foot. (b) "UNREINFORCED MASONRY BEARING WALL:" A masonry wall having all of the following characteristics: 1. Provide the vertical support for a floor or roof. o The total superimposed load is over 100 pounds per linear foot. ORIGINAL The area of reinforcing steel is less than 25 percent of the minimum steel ratios required by the Building Code for reinforced masonry. (c) "ARCHITECT OR ENGINEER:" California licensed Architect or California licensed Civil or Structural Engineer in responsible charge of the structural design work for the project. 15.40.040 Material requirements. (a) Existing Materials. All existing materials utilized as part of the lateral force resisting system shall be in sound condition or shall be removed and replaced with new materials. (b) Existing Unreinforced Masonry: 1. General. Unreinforced masonry walls shall be tested as specified in this subsection. Masonry that does not meet or exceed the minimum standards established by this Chapter shall be removed and replaced by new materials and anchored to supporting elements; design of anchorage shall comply with requirements for anchorage of masonry veneer of Section 15.40.070(g). 2. Lay-Up of Walls. The facing and backing shall be bonded so that not less than 4 percent of the wall surface of each face is composed of solid headers extending not less than 4 inches into the backing. The distance between adjacent full-length headers shall not exceed 24 inches either vertically or horizontally. In walls in which a single header does not extend through the wall, headers from opposite sides shall overlap at least four inches, or headers from opposite sides shall be covered with another header course overlapping the header below at least four inches. Wythes of walls not bonded as described above shall be considered as veneer. The veneer wythe shall not be included in the effective thickness used in calculating the height to thickness ratio of the wall unless it is bonded and anchored to the backing in a manner acceptable to the City Building Official. 3. Mortar A. Tests. The quality of mortar in unreinforced masonry walls shall be determined by performing in- place shear tests in accordance with Uniform Building Code Standard (24-7). Alternate methods of testing to establish compliance with the minimum requirement of Section 15.40.040 (b) 3. D. (IV) may be approved by the City Building Official. B. Location of Tests. Shear tests shall be taken at locations representative of the mortar conditions throughout the entire building. The exact test location shall be determined at the building site by the Architect or Engineer. An accurate record of such tests and their location in the building shall be recorded and these results shall be submitted to the City Building Official for approval as part of the structural analysis. 3 C. Number of Tests. The minimum number of tests per wall or line of wall elements providing a common line of resistance to lateral forces shall be as follows: Two (2) tests per wall with a minimum total number of 8 tests or one test per 1,500 square feet of wall area, whichever results in the greater number of tests. D. Minimum Quality Mortar. (I) Mortar shear test values, Vto. shall be obtained for each in-place shear test in accordance with the following equation: Vto = (Vte~t WHERE: Vto PD,L) /~ .................. (7--1) Mortar shear test value, in psi. Shear stress at incipient cracking for each in-place test per Standard No. 24.7. Actual dead plus live load in place at the time of testing, in pounds. Area of the wall supporting PD+L at each in-place shear test. (II) Individual unreinforced masonry wall with vto less than 30 psi shall be pointed prior to retesting. (III) The mortar shear strength, vt is the value in psi representing a minimum of 80% of all of the mortar shear test values, Vto. (IV) Unreinforced masonry with mortar shear strength, v¢ less than 30 psi shall be removed or pointed and retested. E. Pointing. All deteriorated mortar joints in unreinforced masonry walls shall be pointed according to Standard No. 24-9. Nothing shall prevent pointing with mortar of all masonry wall joints before the tests are made. 15.40.050 Oualit¥ control. (a) Pointing. Special inspection shall be provided during preparation and mortar pointing. Exception: Pointing may be performed without special inspection where approved by the Architect or Engineer. 4 ORIGIHAL ~ (b) Existing Floor or Roof Level Wall Anchors. 1. Floor level tension anchors embedded in brick. If existing rod anchors embedded in brick are to be utilized as all or part of the required wall anchorage system at the floor level, not less than 5 percent of such existing rod anchors shall be tested by an approved testing laboratory or under the supervision of the Architect or Engineer. The minimum number of anchors tested shall be four per floor, with two tests at walls with joists framing into the wall and two tests at walls with joists parallel to the wall but not less than 5 percent of the total number of existing tension anchors at each level. The test apparatus shall be supported on the masonry wall at a minimum distance of the wall thickness from the anchor tested. The rod anchor shall be given a preload of 300 lbs. prior to establishing a datum for recording elongation. The tension test load reported shall be recorded at one-eighth inch relative movement of the anchor and the adjacent masonry surface. Results of all tests shall be reported. The report shall include the test results as related to the wall thickness and joist orientation. Ends of existing anchors shall be secured into the wood framing by a positive mechanical attachment. 2. Floor or roof level anchors embedded in concrete. Existing rod anchors at floor or roof levels that are embedded in existing concrete or gunite applied to the opposite side of the wall need not be tested provided such embedment is verified by observation and report by an approved testing agency or the Architect or Engineer for at least one anchor, and all anchors observed, in each wall at each level for which such the anchors are to be utilized as all or part of the required wall anchorage system. Other evidence of such embedment may be approved by the City Building Official. (c) Testing of Bolts. One-fourth of new embedded bolts in unreinforced masonry walls shall be tested by a testing laboratory or Architect or Engineer using the procedure of U.B.C. Standard No. 24-8. Exception: Special inspection in accordance with the Building Code or continuous observation by the Architect or Engineer may be provided during installation in lieu of testing. (d) Required Reports. The Architect or Engineer or testing agency shall submit a signed report to the City Building Official for each test, observation or inspection required by Section 15.40.050 and 15.40.070(g). The report shall state the test, observation, or inspection performed, the date, the results of each individual test, observation or inspection, (including those that fail to satisfy the intent of this Ordinance) and 5 ORIGINAL whether to the best of the knowledge of the preparer of the report, the results indicate compliance with this Ordinance. 15.40.060 Allowable desiqn values. (a) Tension Anchors. Allowable values for tension anchors are given in Table No. 1-B. A one-third increase is not allowed for values listed in this table. (b) Other Materials. Allowable values not specified in this chapter shall be as specified elsewhere in the 1991 Uniform Building Code. 15.40.070 Detailed systems design requirements. (a) Lateral Force on Elements of Structures and Nonstructural Components. Parts or portions of structures, nonstructural components and their anchorage to the main structural system shall be designed for lateral forces in accordance with the following formula: F = C W ................... (10-1) P P P Wp shall be as defined in Section 2332. The value of Cp need not exceed the values set forth in Table No. 1C. (b) Height to Thickness Limitations. Unreinforced masonry wall height to thickness ratios shall not exceed the ratios set forth in Table No. 1D. If a wall height to thickness ratio exceeds the specified limits, the wall shall be laterally supported by bracing members complying with Subsection (c)l or with Subsection (c)2. Bracing systems shall be designed in accordance with Section 15.40.070(a). The wall thickness may include the thickness of plaster, stucco or concrete that is determined by the Architect or Engineer to be bonded to the full height of the wall between wall anchors. (c) Bracing Methods. 1. Vertical Bracing Members. Vertical bracing members shall be attached to floor and roof construction for their design loads independent of required wall anchors. Horizontal spacing of vertical bracing members shall not exceed one-half the unsupported height of the wall nor 10 feet. Deflection of such bracing members at design loads, shall not exceed one-tenth of the wall thickness. 2. Wall Bracing. The wall height may be measured to bracing elements other than a floor or roof. Horizontal spacing of the bracing elements and wall anchors shall not exceed 6 feet on center nor 6 times the wall thickness, whichever is less. Bracing elements shall be 6 ORIGINAl. detailed to minimize the horizontal displacement of the wall by the vertical displacement of the floor or roof. (d) Wall Anchorage. 1. Anchor Locations. Unreinforced masonry walls shall be anchored at the roof and floor levels in order to resist the forces specified in this section. 2. Tension Anchor Requirements. Tension anchors shall have a maximum spacing of 6 feet or 6 times the wall thickness, whichever is less, and shall comply with the requirements set forth in Table No. 1-B. Tension anchors used to resist required forces may be assumed to develop the allowable values listed in Table No. 1-B. Tension anchors shall be secured to the rafters or joists to transfer the required forces into the roof or floor sheathing. 3. New Tension Anchors. New Tension Anchors installed to meet the requirements of this section shall be Combination Tension and Shear Bolts, and shall be secured to the roof or flo0r framing to develop tension and shear forces into the diaphragm. 4. Minimum Wall Anchorage Forces. New or existing Tension Anchors shall anchor masonry walls to each floor or roof with a capacity to resist a minimum tension force determined by Formula (10-1) or 200 pounds per linear foot whichever is greater, acting normal to the wall at the level of the floor or roof. In addition, new Combination Tension and Shear Bolts shall be connected to the framing to resist a shear force of 200 pounds per foot acting parallel to the wall at the level of the floor or roof. Exception: Where the roof or floor sheathing consists only of 1 inch nominal thickness single board sheathing, new Combination Tension and Shear Bolts may be connected to the framing to resist a shear force of 100 pounds per foot acting parallel to the wall. The City Building Official may approve an analysis by the Architect or Engineer that demonstrates that the required shear capacity is less than required by this section. 5. Anchors at Corners. New Combination Tension and Shear Bolts at the roof and floor levels, if required by this Section, shall be provided within two feet horizontally from the inside of the corners of the walls." (e) Parapets. Parapets and exterior wall appendages not capable of resisting the forces specified in this section shall be removed, stabilized or braced to ensure that the parapets and appendages remain in their original position. 7 ORIGINAL The maximum height of an unbraced unreinforced masonry parapet above the level of tension anchors shall not exceed one and one-half (1-1/2) times the thickness of the parapet wall. If the required parapet height exceeds this maximum height, a bracing system designed for the force determined by formula (10-1) shall be installed to support the parapet. Parapet corrective work shall be performed in conjunction with the installation of tension roof anchors. The minimum height of a parapet above the wall anchor shall be twelve (12) inches. Exception: If a reinforced concrete beam is provided at the top of the wall, the minimum height above the wall anchor may be six (6) inches. (f). Mortar Joints. All deteriorated mortar joints in unreinforced masonry walls shall be pointed with Type S or N mortar. Masonry cements shall not be used. Prior to any pointing, the wall surface must be raked and cleaned to remove loose and deteriorated mortar. All preparation for pointing shall be inspected by the Architect or Engineer or their representative. (g). Masonry Veneer. 1. Veneer shall be anchored to the structure of the building with approved anchor ties conforming to the required design capacity specified in the Building Code and placed at a maximum spacing of 24 inches with a maximum supported area of 2 square feet. EXCETPION: I. Existing masonry veneer anchor ties may be acceptable provided the ties are in sound condition and conform to the following minimum size, maximum spacing and material requirements: Existing masonry veneer anchor ties shall be corrugated galvanized iron strips not less than 1 inch in width, 8 inches in length and 1/16 inch in thickness and shall be located and laid in every alternate course in the vertical height of the wall at a spacing not to exceed 17 inches on center horizontally. As an alternate, such ties may be laid in every fourth course vertically at a spacing not to exceed 9 inches on center horizontally. II. Masonry veneer, no portion of which 6 feet is above grade need not be anchored. 2. The location and condition of existing veneer anchor ties shall be verified as follows: ORIGINAL The Architect or Engineer shall determine the location and spacing of the ties. The veneer shall be removed from not less than four locations designated by the Architect or Engineer for the Architect or Engineer's evaluation. The Architect or Engineer shall report to the City Building Official the veneer anchor tie locations and spacings, their evaluation of the condition and effectiveness of the veneer anchor ties, and their recommendations whether or not the existing veneer anchor ties need to be supplemented with new veneer anchor ties. 3. Unreinforced masonry walls which carry no loads other than their own weight may be considered as veneer if they are adequately anchored to new supporting elements. Nos. i-A, 15.40.080 Tables and Standards. For Time Limits and Technical Specifications see Table l-B, l-C, and l-D; Standard Nos. 24-7 and 24-9. TABLE NO. 1-A TIME LIMITS FOR PROCEEDINGS FOLLOWING DECEMBER 31, 1998 DEADLINE Required Action By Owner Obtain Building Permit Within Commence Construction Within Complete Construction Within Anchorage Installation Buildings to be Demolished 1 Year (1) 180 Days (2) 1 Year (1) 180 Days (2) 1 Year (2) 1 Year (2) (1) Measured from the date of the order. (2) Measured from the date of building permit issuance. (3) These time limits shall not apply to a change of occupancy involving a Group A Occupancy having an occupant load of 100 or more. ORIGINAL TABLE NO. 1-B ALLOWABLE VALUES FOR TENSION ANCHORS TyDe of Installation EXISTING TENSION ANCHORS: Anchors at floor level embedded in brick (to be tested per Section 15.40.050(b) Allowable Values (1) Allowable shall be 40% of the average of the tests for anchors having same wall thickness and joist orientation. Anchors at floor or roof levels embedded in existing concrete or gunite on the opposite side of the wall. (2) TENSION BOLTS: Bolts extending entirely through unreinforced masonry walls secured with bearing plates on far side of a 3 wythe minimum wall with a bearing plate having an area of at least 30 square inches. (2) (3) 1800 lb. per anchor. 1800 lbs. per bolt. 900 lbs. for 2 wythe walls. COMBINATION TENSION AND SHEAR BOLTS: Combination tension and shear bolts are tension bolts centered in a 2-1/2 inch diameter by 8 inch minimum depth hole with dry-pack or nonshrink grout around the circumference of bolt. EMBEDDED BOLTS Bolts extending to the exterior wall with a 2-1/2 inch round plate under the head and drilled at an angle of 22-1/2 degrees to the horizontal. Bolts shall be centered in 2-1/2 inch diameter holes with dry-pack or non-shrink grout around circumference of bolts. Bolts shall be tested per Section 15.40.050(c). Same as for tension bolts. 1200 pounds. 10 ORIGINAL (1) A one-third increase in allowable stresses is not allowed for the tabulated values. The allowable capacity shall not be greater than the capacity of the connection to the floor or roof framing. (2) (3) Bolts to be 1/2 inch minimum in diameter. Drilling for bolts and dowels shall be done with an electric rotary drill. Impact tools shall not be used for drilling holes or tightening anchors and shear bolt nuts. TABLE NO. 1-C HORIZONTAL FORCE FACTOR "Cp" FOR PARTS OR PORTIONS OF BUILDINGS OR OTHER STRUCTURES Part or Portion of Buildings Exterior bearing and nonbearing walls; interior bearing walls and partitions; interior non- bearing walls and partitions over 10 feet in height. Direction Value of Force C Normal-to-flat 0.3 surface of Cantilever parapet and other cantilever walls, except retaining walls. Normal-to-flat 1.00 surface Exterior and interior ornamen- tations and appendages. Any direction 1.00 Prefabricated structural elements, other than walls, with force applied at center of gravity of assembly. Any horizontal 0.30 direction Connections for exterior panels or elements. Any direction 2.00 11 ORIGINAL TABLE NO. 1-D ALLOWABLE VALUE OF HEIGHT-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS WITH MINIMUM QUALITY MORTAR Buildings with Crosswalls As Defined by Section 15.40.030 All Other Buildings Walls of one-story buildings First-story walls of two-story buildings Walls in top story of Multi-story buildings 16 13 16 15 14 9 All other walls 16 13 '12 ORIGINAL SECTION 2. This ordinance shall be posted in accordance with provisions of the Bakersfield Municipal Code and shall become effective thirty (30) days from and after the date of its passage. .......... o0o .......... I HEREBY CERTIFY that the foregoing Ordinance was passed and adopted by the Council of the City of Bakersfield at a regular meeting thereof held on AUG 1 1 .t~__~_% , by the following vote: AYES: COUNCILMEMBERS McDERMOTT, EDWARDS, DeMOND, SIdlTN, BR[,,%INI, ROWLES, ~kLVAGOJO NOES: COUNCILMEMBERS ~.)O f'J ~:. ABSTAIN: COUNCILMEMBERS fOc~ f,~ ~, ABSENT: COUNCILMEMBERS ~/~K~ ~ CITY CLERK and Ex Officio Clerk of the Council of the City of Bakersfield APPROVED AUG I APPROVED as to form: LAWRENCE M. LUNARDINI CITY ATTORNEY of the City of Bakersfield LCM/kg 7-12-93 13 ORIGINAL AFFIDAVIT OF POSTING DOCUMENTS STATE OF CALIFORNIA) ) SS. County of Kern ) CAROL WILLIAMS, being duly sworn, deposes and says: That she is the duly appointed, acting and qualified City Clerk of the City of Bakersfield; and that on the 13th day of August, 1993 she posted on the Bulletin Board at City Hall, a full, true and correct copy of the following: Ordinance No. 3552, passed by the Bakersfield City Council at a meeting held on the 11th day of August, 1993, and entitled: AN ORDINANCE AMENDING CHAPTER 15.40 OF THE BAKERSFIELD MUNICIPAL CODE RELATING TO UNREINFORCED BUILDINGS. By: /s/ CAROL WILLIAMS City Clerk of the City of Bakersfield DEPUTY C~y C~rk