Loading...
HomeMy WebLinkAbout2024 FMCAppendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10901998 01/25/2024 Skyway Liquors 4199 Union Ave Bakersfield 93305 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 VeederRoot TLS-3XX Technician - C32655 10/11/2024 Vaporless Manufacturing Inc. - #5265 10/21/2024 OPW - 1193585 04/14/2025 01/25/2024 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 Dispenser 1-2 UDC L2 304 Dispenser 1-2 UDC ANN L3 208 Dispenser 3-4 UDC L4 304 Dispenser 3-4 UDC ANN L5 208 Dispenser 5-6 UDC L6 304 Dispenser 5-6 UDC ANN L7 208 Dispenser 7-8 UDC L8 304 Dispenser 7-8 UDC ANN L9 208 91 STP L10 304 91 STP Annular L11 208 91 Fill L12 304 91 Fill Annular L13 208 87 STP L14 304 87 STP Annular L15 208 87 Fill L16 304 87 Fill Annular L17 208 Diesel STP L18 304 Diesel STP Annular L19 208 Diesel Fill L20 304 Diesel Fill Annular L21 304 Vent Box ANN L22 208 Vent Box Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 S6 463/464 91 Vacuum Product S7 463/464 Tank Annular S8 463/464 91 Vacuum Vent S9 463/464 87 Vacuum Product S10 463/464 87 Vacuum Vent S11 463/464 87 Vacuum Vapor S12 463/464 Diesel Vacuum Product S13 463/464 Diesel Vacuum Vent Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Q1 848480-001 87 Unleaded Q2 848480-001 91 Premium Q3 848480-001 Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ 91 PNL Fill ANN reservoir cup leaks brine; repairs required. 304 sensor functions properly. *Return Trip requested to repair and re-test 91 PNL Fill ANN brine reservoir. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Skyway Liquors4199 Union AveBakersfield 109019983-47-8MPDMPDMPDMPD1-25-6ProductProductProductProductBrandon Nunez Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10901998 01/25/2024 Skyway Liquors 4199 Union Ave Bakersfield 93305 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 OPW - 1193585 04/14/2025 PEI 1200 1 Hour Hydrostatic All Spill Containers 01/25/2024 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1: 87 UNL OPW T2: 91 PNL OPW T3: DSL OPW Skyway System Setup Responses Received: 200 SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 JAN 25, 2024 8:40 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 REGULAR 87 8684 56.30 0.0 61.2 11396 2 SUPER 91 3166 75.91 0.8 60.5 1863 3 DIESEL 2424 61.21 0.0 64.0 2605 I90500 JAN 25, 2024 8:40 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JAN 25, 2024 8:40 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JAN 25, 2024 8:40 AM SHIFT TIME 1 : DISABLED I50202 JAN 25, 2024 8:40 AM SHIFT TIME 2 : DISABLED I50203 JAN 25, 2024 8:40 AM SHIFT TIME 3 : DISABLED I50204 JAN 25, 2024 8:40 AM SHIFT TIME 4 : DISABLED I54600 JAN 25, 2024 8:40 AM TANK PER TST NEEDED WRN: DISABLED I54900 JAN 25, 2024 8:40 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JAN 25, 2024 8:40 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JAN 25, 2024 8:40 AM LINE PER TST NEEDED WRN: DISABLED I55900 JAN 25, 2024 8:40 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JAN 25, 2024 8:40 AM PRINT TC VOLUMES ENABLED I50E00 JAN 25, 2024 8:40 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JAN 25, 2024 8:40 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JAN 25, 2024 8:40 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JAN 25, 2024 8:40 AM DAYLIGHT SAVING TIME DISABLED I51B00 JAN 25, 2024 8:40 AM I51600 JAN 25, 2024 8:40 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JAN 25, 2024 8:40 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JAN 25, 2024 8:40 AM TANK CHART SECURITY DISABLED I5BD00 JAN 25, 2024 8:40 AM CUSTOM ALARM LABELS DISABLED I56000 JAN 25, 2024 8:40 AM MASS/DENSITY DISABLED I88101 JAN 25, 2024 8:40 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JAN 25, 2024 8:40 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JAN 25, 2024 8:40 AM I88104 JAN 25, 2024 8:40 AM I88105 JAN 25, 2024 8:40 AM I88106 JAN 25, 2024 8:40 AM I52000 JAN 25, 2024 8:40 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAR 11, 2023 DISABLED 2 ON DATE MAR 11, 2023 DISABLED 3 ON DATE MAR 11, 2023 DISABLED 4 ON DATE MAR 11, 2023 DISABLED 5 ON DATE MAR 11, 2023 DISABLED 6 ON DATE MAR 11, 2023 DISABLED 7 ON DATE MAR 11, 2023 DISABLED 8 ON DATE MAR 11, 2023 DISABLED I60100 JAN 25, 2024 8:41 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 REGULAR 87 ON 2 SUPER 91 ON 3 DIESEL ON 4 OFF I60200 JAN 25, 2024 8:41 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 REGULAR 87 2 SUPER 91 3 DIESEL 4 I60300 JAN 25, 2024 8:41 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 REGULAR 87 1 2 SUPER 91 2 3 DIESEL 3 4 4 I60900 JAN 25, 2024 8:41 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 REGULAR 87 0.000700 2 SUPER 91 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 JAN 25, 2024 8:41 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 REGULAR 87 126.00 2 SUPER 91 126.00 3 DIESEL 126.00 4 0.00 I60A00 JAN 25, 2024 8:41 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 REGULAR 87 4 PTS 20080 2 SUPER 91 4 PTS 5029 3 DIESEL 1 PT 5029 4 1 PT 0 I60400 JAN 25, 2024 8:41 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR 87 20080 2 SUPER 91 5029 3 DIESEL 5029 4 0 I60500 JAN 25, 2024 8:41 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR 87 20080 16154 10040 3926 2 SUPER 91 5029 4046 2514 983 3 DIESEL 5029 0 0 0 4 0 0 0 0 I60600 JAN 25, 2024 8:41 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR 87 20080 0 0 0 0 16154 0 0 0 0 10040 0 0 0 0 3926 0 0 0 0 2 SUPER 91 5029 0 0 0 0 4046 0 0 0 0 2514 0 0 0 0 983 0 0 0 0 3 DIESEL 5029 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JAN 25, 2024 8:41 AM TANK PRODUCT LABEL METER DATA 1 REGULAR 87 NO 2 SUPER 91 NO 3 DIESEL NO 4 NO I62F00 JAN 25, 2024 8:41 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 REGULAR 87 3.0 IN. 2 SUPER 91 3.0 IN. 3 DIESEL 3.0 IN. I62700 JAN 25, 2024 8:41 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR 87 2.0 2 SUPER 91 2.0 3 DIESEL 2.0 I64200 JAN 25, 2024 8:41 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 REGULAR 87 LOW 2 SUPER 91 LOW 3 DIESEL LOW I62400 JAN 25, 2024 8:41 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR 87 3.0 2 SUPER 91 3.0 3 DIESEL 3.0 I62800 JAN 25, 2024 8:41 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 20080 2 SUPER 91 5029 3 DIESEL 5029 4 0 I62300 JAN 25, 2024 8:41 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 18072 2 SUPER 91 4526 3 DIESEL 4526 4 0 I62200 JAN 25, 2024 8:41 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 19076 2 SUPER 91 4778 3 DIESEL 4778 4 0 I62900 JAN 25, 2024 8:41 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 2008 2 SUPER 91 503 3 DIESEL 503 4 0 I62100 JAN 25, 2024 8:41 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 800 2 SUPER 91 500 3 DIESEL 500 4 0 I62600 JAN 25, 2024 8:41 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 99 2 SUPER 91 99 3 DIESEL 99 4 99 I62500 JAN 25, 2024 8:41 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 99 2 SUPER 91 99 3 DIESEL 99 4 99 I60800 JAN 25, 2024 8:41 AM TANK TILT TANK PRODUCT LABEL INCHES 1 REGULAR 87 0.00 2 SUPER 91 0.00 3 DIESEL 0.00 4 0.00 I60B00 JAN 25, 2024 8:41 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JAN 25, 2024 8:41 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 REGULAR 87 0.00 2 SUPER 91 0.00 3 DIESEL 0.00 4 0.00 I61200 JAN 25, 2024 8:41 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 REGULAR 87 NONE NONE 2 SUPER 91 NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 JAN 25, 2024 8:41 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR 87 0 2 SUPER 91 0 3 DIESEL 0 4 0 I62A00 JAN 25, 2024 8:41 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR 87 0 2 SUPER 91 0 3 DIESEL 0 4 0 I62C00 JAN 25, 2024 8:41 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 REGULAR 87 STANDARD 2 SUPER 91 STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 JAN 25, 2024 8:41 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 REGULAR 87 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPER 91 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JAN 25, 2024 8:41 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 REGULAR 87 OFF OFF 2 SUPER 91 OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 JAN 25, 2024 8:41 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 REGULAR 87 OFF 2 SUPER 91 OFF 3 DIESEL OFF 4 OFF I63200 JAN 25, 2024 8:41 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 REGULAR 87 OFF 2 SUPER 91 OFF 3 DIESEL OFF 4 OFF I61000 JAN 25, 2024 8:41 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 REGULAR 87 3 2 SUPER 91 3 3 DIESEL 3 4 1 I63A00 JAN 25, 2024 8:41 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 REGULAR 87 10.00% 2 SUPER 91 10.00% 3 DIESEL 10.00% 4 10.00% I61100 JAN 25, 2024 8:41 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK APR 26, 2020 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JAN 25, 2024 8:41 AM CSLD PROBABLITY OF DETECTION I61400 JAN 25, 2024 8:41 AM CSLD CLIMATE FACTOR I61600 JAN 25, 2024 8:41 AM TANK PRODUCT LABEL CAL UPDATE 1 REGULAR 87 IMMEDIATE 2 SUPER 91 IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 JAN 25, 2024 8:41 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 REGULAR 87 DISABLED 2 SUPER 91 DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 JAN 25, 2024 8:41 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JAN 25, 2024 8:41 AM CSLD REPORT ONLY I62B00 JAN 25, 2024 8:41 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 REGULAR 87 ??? 0, 0 2 SUPER 91 ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 JAN 25, 2024 8:41 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JAN 25, 2024 8:41 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 0 2 SUPER 91 0 3 DIESEL 0 4 0 I63500 JAN 25, 2024 8:41 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR 87 1 2 SUPER 91 1 3 DIESEL 1 4 1 I63900 JAN 25, 2024 8:41 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 REGULAR 87 END FACTOR: NONE 2 SUPER 91 END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 JAN 25, 2024 8:41 AM PRESSURE LINE LEAK SETUP Q 1:REGULAR UNL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 150 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 1:REGULAR 87 DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:SUPER 91 TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 150 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 2:SUPER 91 DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:DIESEL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 150 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 3:DIESEL DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO I77700 JAN 25, 2024 8:41 AM I77800 JAN 25, 2024 8:41 AM I78C00 JAN 25, 2024 8:41 AM I78300 JAN 25, 2024 8:41 AM I78F00 JAN 25, 2024 8:41 AM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSURE Q 1:REGULAR UNL 0 PSI Q 2:SUPER 91 0 PSI Q 3:DIESEL 0 PSI I78700 JAN 25, 2024 8:41 AM PRESSURE LLD SETUP REPORT Q 1:REGULAR UNL IN-TANK ALARMS T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 5:FUEL ALARM L 7:FUEL ALARM L13:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 5:SHORT ALARM L 7:SHORT ALARM L13:SHORT ALARM SMARTSENSOR ALARMS s 9:HIGH LIQUID ALARM s10:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 2:SUPER 91 IN-TANK ALARMS T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 5:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM SMARTSENSOR ALARMS s 6:HIGH LIQUID ALARM s 7:HIGH LIQUID ALARM s 8:HIGH LIQUID ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 3:DIESEL IN-TANK ALARMS T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 5:FUEL ALARM L 7:FUEL ALARM L17:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L17:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 5:SHORT ALARM L 7:SHORT ALARM L17:SHORT ALARM SMARTSENSOR ALARMS s12:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM I70200 JAN 25, 2024 8:41 AM LIQUID LABEL DEVICE LABEL 1 DISP 1-2 2 DISP 1-2 ANN 3 DISP 3-4 4 DISP 3-4 ANN 5 DISP 5-6 6 DISP 5-6 ANN 7 DISP 7-8 8 DISP 7-8 ANN 9 91 STP 10 91 STP ANN 11 91 FILL 12 91 FILL ANN 13 87 STP 14 87 STP ANN 15 87 FILL 16 87 FILL ANN 17 DIESEL STP 18 DSL STP ANN 19 DIESEL FILL 20 DSL FILL ANN 21 VENT BOX ANN 22 VENT BOX 23 24 I70300 JAN 25, 2024 8:41 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1-2 TRI-STATE (SINGLE FLOAT) 2 DISP 1-2 ANN TRI-STATE (SINGLE FLOAT) 3 DISP 3-4 TRI-STATE (SINGLE FLOAT) 4 DISP 3-4 ANN TRI-STATE (SINGLE FLOAT) 5 DISP 5-6 TRI-STATE (SINGLE FLOAT) 6 DISP 5-6 ANN TRI-STATE (SINGLE FLOAT) 7 DISP 7-8 TRI-STATE (SINGLE FLOAT) 8 DISP 7-8 ANN TRI-STATE (SINGLE FLOAT) 9 91 STP TRI-STATE (SINGLE FLOAT) 10 91 STP ANN TRI-STATE (SINGLE FLOAT) 11 91 FILL TRI-STATE (SINGLE FLOAT) 12 91 FILL ANN TRI-STATE (SINGLE FLOAT) 13 87 STP TRI-STATE (SINGLE FLOAT) 14 87 STP ANN TRI-STATE (SINGLE FLOAT) 15 87 FILL TRI-STATE (SINGLE FLOAT) 16 87 FILL ANN TRI-STATE (SINGLE FLOAT) 17 DIESEL STP TRI-STATE (SINGLE FLOAT) 18 DSL STP ANN TRI-STATE (SINGLE FLOAT) 19 DIESEL FILL TRI-STATE (SINGLE FLOAT) 20 DSL FILL ANN TRI-STATE (SINGLE FLOAT) 21 VENT BOX ANN TRI-STATE (SINGLE FLOAT) 22 VENT BOX TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 JAN 25, 2024 8:41 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1-2 DISPENSER PAN 2 DISP 1-2 ANN DISPENSER PAN 3 DISP 3-4 DISPENSER PAN 4 DISP 3-4 ANN DISPENSER PAN 5 DISP 5-6 DISPENSER PAN 6 DISP 5-6 ANN DISPENSER PAN 7 DISP 7-8 DISPENSER PAN 8 DISP 7-8 ANN DISPENSER PAN 9 91 STP STP SUMP 10 91 STP ANN STP SUMP 11 91 FILL PIPING SUMP 12 91 FILL ANN PIPING SUMP 13 87 STP STP SUMP 14 87 STP ANN STP SUMP 15 87 FILL PIPING SUMP 16 87 FILL ANN PIPING SUMP 17 DIESEL STP STP SUMP 18 DSL STP ANN STP SUMP 19 DIESEL FILL PIPING SUMP 20 DSL FILL ANN PIPING SUMP 21 VENT BOX ANN DISPENSER PAN 22 VENT BOX DISPENSER PAN 23 OTHER SENSORS 24 OTHER SENSORS I74200 JAN 25, 2024 8:41 AM I74300 JAN 25, 2024 8:41 AM I74400 JAN 25, 2024 8:41 AM I74700 JAN 25, 2024 8:41 AM I74800 JAN 25, 2024 8:41 AM I74900 JAN 25, 2024 8:41 AM I7BC00 JAN 25, 2024 8:42 AM I80200 JAN 25, 2024 8:42 AM I80300 JAN 25, 2024 8:42 AM I80400 JAN 25, 2024 8:42 AM I80700 JAN 25, 2024 8:42 AM RELAY LABEL DEVICE LABEL 1 OVER FILL ALARM 2 3 4 I80900 JAN 25, 2024 8:42 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 OVER FILL ALARM NORMALLY OPEN 2 NORMALLY OPEN 3 NORMALLY OPEN 4 NORMALLY OPEN I80B00 JAN 25, 2024 8:42 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 OVER FILL ALARM NONE 2 NONE 3 NONE 4 NONE I80A00 JAN 25, 2024 8:42 AM RELAY TYPE RELAY DESIGNATION TYPE 1 OVER FILL ALARM STANDARD 2 STANDARD 3 STANDARD 4 STANDARD I80C00 JAN 25, 2024 8:42 AM I80800 JAN 25, 2024 8:42 AM RELAY SETUP REPORT R 1:OVER FILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 JAN 25, 2024 8:42 AM EDIM:1 VR:349867-001-D TD:17.02.14.08.38 I79100 JAN 25, 2024 8:42 AM I72300 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DISP 1-2FM AIR FLOW METER 02 DISP 3-4FM AIR FLOW METER 03 DISP 5-6FM AIR FLOW METER 04 DISP 7-8FM AIR FLOW METER 05 DISP 1-2PS VAPOR PRESSURE 06 91 VACCUM PRODUCT VAC SENSOR 07 TANK ANN VAC SENSOR 08 91 VACCUM VENT VAC SENSOR 09 87 VACCUM PRODUCT VAC SENSOR 10 87 VACCUM VENT VAC SENSOR 11 87 VACCUM VAPOR VAC SENSOR 12 DIESEL VACCUM PRODUC VAC SENSOR 13 DIESEL VACCUM VENT VAC SENSOR 14 UNKNOWN 15 UNKNOWN 16 ATM P SENSOR ATM P SENSOR 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 EVR/ISD SETUP TYPE: BALANCE IV4F00 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 VAPOR PROCESSOR TYPE NONE IV4700 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 ASSESSMENT TIME START TIME: 11:59 PM TIME DELAY MINUTES: 1 IV5200 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 ACCEPT HIGH ORVR: NO IV4A00 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND3 02 02 02 01 UU BLEND3 03 03 03 02 UU BLEND3 04 04 04 02 UU BLEND3 05 05 05 03 UU BLEND3 06 06 06 03 UU BLEND3 07 07 07 04 UU BLEND3 08 08 08 04 UU BLEND3 IV4B00 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JAN 25, 2024 8:42 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JAN 25, 2024 8:42 AM ISD VERSION: 01.06 Skyway Pre Alarm History Responses Received: I10200 JAN 25, 2024 8:43 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 9521986 9804044 2 4 PROBE / G.T. 161602 161771 3 INTERSTITIAL BD 200073 200156 4 INTERSTITIAL BD 199932 200017 5 INTERSTITIAL BD 200543 200597 6 PLLD SENSOR BD 3893 3895 7 8SMARTSENSOR BD 39113 39122 8 7SMARTSENSOR BD 505316 505611 9 RELAY BOARD 14916 14940 10 PLLD POWER BD 100056 99469 11 UNUSED 9491041 9688914 12 UNUSED 9471690 9659864 13 UNUSED 9473988 9657882 14 UNUSED 9467252 9653404 15 UNUSED 9471826 9652179 16 UNUSED 9472952 9649840 COMM 1 ELEC DISP INT. 100447 100447 COMM 2 RS232 SERIAL BD 14984 15007 COMM 3 UNUSED 9481873 9661981 COMM 4 UNUSED 9467951 9653671 COMM 5 UNUSED 9465856 9647879 COMM 6 UNUSED 9465000 9647835 I90200 JAN 25, 2024 8:43 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JAN 25, 2024 8:43 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L10 STP SUMP 91 STP ANN FUEL ALARM ALARM 1-25-24 8:42AM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM CLEAR 1-16-24 9:12AM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM ALARM 1-16-24 9:03AM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM CLEAR 1-15-24 3:12PM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM ALARM 1-15-24 3:12PM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM CLEAR 1-15-24 12:10PM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM ALARM 1-15-24 11:17AM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM CLEAR 1-15-24 11:03AM L16 PIPE 87 FILL ANN FUEL ALARM CLEAR 1-09-24 1:16PM L16 PIPE 87 FILL ANN FUEL ALARM ALARM 1-09-24 1:16PM L10 STP SUMP 91 STP ANN FUEL ALARM CLEAR 1-09-24 12:07PM s 7 OTHER TANK ANN NO VACUUM ALARM CLEAR 1-09-24 12:04PM L10 STP SUMP 91 STP ANN FUEL ALARM ALARM 1-09-24 12:03PM s 8 OTHER 91 VACCUM VENT NO VACUUM ALARM CLEAR 1-09-24 12:01PM s 7 OTHER TANK ANN NO VACUUM ALARM ALARM 1-09-24 11:17AM s 7 OTHER TANK ANN NO VACUUM ALARM CLEAR 1-09-24 11:15AM s 7 OTHER TANK ANN NO VACUUM ALARM ALARM 1-09-24 10:55AM s 7 OTHER TANK ANN NO VACUUM ALARM CLEAR 1-09-24 10:35AM s 7 OTHER TANK ANN NO VACUUM ALARM ALARM 1-09-24 10:34AM s 7 OTHER TANK ANN NO VACUUM ALARM CLEAR 1-09-24 10:24AM s 7 OTHER TANK ANN NO VACUUM ALARM ALARM 1-09-24 10:10AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM CLEAR 1-09-24 10:02AM s 8 OTHER 91 VACCUM VENT HIGH LIQUID ALARM CLEAR 1-09-24 10:02AM s 6 OTHER 91 VACCUM PRODUCT HIGH LIQUID ALARM CLEAR 1-09-24 10:02AM s 6 OTHER 91 VACCUM PRODUCT HIGH LIQUID ALARM ALARM 1-09-24 10:01AM s 8 OTHER 91 VACCUM VENT HIGH LIQUID ALARM ALARM 1-09-24 10:01AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM ALARM 1-09-24 10:01AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM CLEAR 1-09-24 9:33AM s 7 OTHER TANK ANN HIGH LIQUID ALARM CLEAR 1-09-24 9:33AM s 7 OTHER TANK ANN HIGH LIQUID ALARM ALARM 1-09-24 9:33AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM ALARM 1-09-24 9:33AM s 8 OTHER 91 VACCUM VENT NO VACUUM ALARM ALARM 1-09-24 9:31AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM CLEAR 1-09-24 9:29AM s 8 OTHER 91 VACCUM VENT HIGH LIQUID ALARM CLEAR 1-09-24 9:29AM s 6 OTHER 91 VACCUM PRODUCT HIGH LIQUID ALARM CLEAR 1-09-24 9:29AM s 6 OTHER 91 VACCUM PRODUCT HIGH LIQUID ALARM ALARM 1-09-24 9:25AM s 8 OTHER 91 VACCUM VENT HIGH LIQUID ALARM ALARM 1-09-24 9:25AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM ALARM 1-09-24 9:25AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM CLEAR 1-09-24 9:07AM s 6 OTHER 91 VACCUM PRODUCT HIGH LIQUID ALARM CLEAR 1-09-24 9:07AM s 8 OTHER 91 VACCUM VENT HIGH LIQUID ALARM CLEAR 1-09-24 9:07AM s 6 OTHER 91 VACCUM PRODUCT HIGH LIQUID ALARM ALARM 1-09-24 9:03AM s 8 OTHER 91 VACCUM VENT HIGH LIQUID ALARM ALARM 1-09-24 9:03AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM ALARM 1-09-24 9:03AM Q 1 OTHER REGULAR UNL PLLD SHUTDOWN ALARM CLEAR 1-09-24 9:02AM s11 OTHER 87 VACCUM VAPOR HIGH LIQUID ALARM CLEAR 1-09-24 9:02AM s10 OTHER 87 VACCUM VENT HIGH LIQUID ALARM CLEAR 1-09-24 9:02AM s 9 OTHER 87 VACCUM PRODUCT HIGH LIQUID ALARM CLEAR 1-09-24 9:02AM s11 OTHER 87 VACCUM VAPOR HIGH LIQUID ALARM ALARM 1-09-24 9:01AM s10 OTHER 87 VACCUM VENT HIGH LIQUID ALARM ALARM 1-09-24 9:01AM I11200 JAN 25, 2024 8:43 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 1-25-24 4:01AM SYSTEM PAPER OUT CLEAR 1-25-24 4:01AM SYSTEM PRINTER ERROR ALARM 1-25-24 3:52AM SYSTEM PAPER OUT ALARM 1-25-24 3:52AM SYSTEM PRINTER ERROR CLEAR 1-16-24 4:58PM SYSTEM PAPER OUT CLEAR 1-16-24 4:58PM SYSTEM PRINTER ERROR ALARM 1-16-24 4:57PM SYSTEM PAPER OUT ALARM 1-16-24 4:57PM SYSTEM PRINTER ERROR CLEAR 1-16-24 4:57PM SYSTEM PAPER OUT CLEAR 1-16-24 4:57PM SYSTEM PRINTER ERROR ALARM 1-16-24 4:57PM SYSTEM PAPER OUT ALARM 1-16-24 4:57PM SYSTEM PRINTER ERROR CLEAR 1-16-24 4:57PM SYSTEM PAPER OUT CLEAR 1-16-24 4:57PM SYSTEM PRINTER ERROR ALARM 1-16-24 4:57PM SYSTEM PAPER OUT ALARM 1-16-24 4:57PM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 1-05-24 8:44AM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 1-05-24 8:44AM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 12-11-23 5:40PM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 12-11-23 4:51PM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 12-08-23 9:45PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:39PM SYSTEM PAPER OUT CLEAR 12-08-23 7:39PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:38PM SYSTEM PAPER OUT ALARM 12-08-23 7:38PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:37PM SYSTEM PAPER OUT CLEAR 12-08-23 7:37PM SYSTEM PAPER OUT ALARM 12-08-23 7:37PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:37PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:36PM SYSTEM PAPER OUT CLEAR 12-08-23 7:36PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:36PM SYSTEM PAPER OUT ALARM 12-08-23 7:36PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:36PM SYSTEM PAPER OUT CLEAR 12-08-23 7:36PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:36PM SYSTEM PAPER OUT ALARM 12-08-23 7:36PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:36PM SYSTEM PAPER OUT CLEAR 12-08-23 7:36PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:35PM SYSTEM PAPER OUT ALARM 12-08-23 7:35PM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 12-08-23 6:16PM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 11-28-23 7:46AM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 11-27-23 3:16PM SYSTEM PRINTER ERROR CLEAR 11-09-23 10:46AM SYSTEM PAPER OUT CLEAR 11-09-23 10:46AM SYSTEM PRINTER ERROR ALARM 11-09-23 10:45AM SYSTEM PAPER OUT ALARM 11-09-23 10:45AM SYSTEM PRINTER ERROR CLEAR 11-01-23 4:03AM SYSTEM PRINTER ERROR ALARM 11-01-23 4:03AM I20600 JAN 25, 2024 8:43 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 TANK ALARM HISTORY TANK 1 REGULAR 87 HIGH WATER ALARM MAY 17, 2023 5:10 PM MAY 13, 2023 9:00 PM LOW PRODUCT ALARM NOV 28, 2023 7:31 AM AUG 10, 2023 6:20 PM MAY 13, 2023 3:26 PM PROBE OUT JAN 5, 2024 8:45 AM HIGH WATER WARNING MAY 17, 2023 5:10 PM MAY 13, 2023 9:00 PM DELIVERY NEEDED JAN 5, 2024 8:44 AM DEC 11, 2023 4:51 PM DEC 8, 2023 6:16 PM TANK 2 SUPER 91 OVERFILL ALARM OCT 9, 2023 7:03 PM HIGH PRODUCT ALARM OCT 9, 2023 7:06 PM TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JAN 25, 2024 8:43 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:REGULAR UNL JAN 9, 2024 9:01 AM PLLD SHUTDOWN ALARM DEC 28, 2023 12:28 PM PLLD SHUTDOWN ALARM DEC 28, 2023 10:07 AM PLLD SHUTDOWN ALARM NOV 28, 2023 7:31 AM PLLD SHUTDOWN ALARM NOV 9, 2023 11:47 AM PLLD SHUTDOWN ALARM NOV 9, 2023 11:47 AM GROSS LINE FAIL NOV 9, 2023 10:41 AM PLLD SHUTDOWN ALARM NOV 9, 2023 10:27 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:54 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:51 AM PLLD SHUTDOWN ALARM Q 2:SUPER 91 JAN 9, 2024 10:01 AM PLLD SHUTDOWN ALARM JAN 9, 2024 9:33 AM PLLD SHUTDOWN ALARM JAN 9, 2024 9:25 AM PLLD SHUTDOWN ALARM JAN 9, 2024 9:03 AM PLLD SHUTDOWN ALARM DEC 28, 2023 1:38 PM PLLD SHUTDOWN ALARM DEC 28, 2023 1:08 PM PLLD SHUTDOWN ALARM DEC 28, 2023 10:02 AM PLLD SHUTDOWN ALARM NOV 9, 2023 11:56 AM PLLD SHUTDOWN ALARM NOV 9, 2023 11:56 AM GROSS LINE FAIL NOV 9, 2023 10:39 AM PLLD SHUTDOWN ALARM Q 3:DIESEL NOV 9, 2023 11:38 AM PLLD SHUTDOWN ALARM NOV 9, 2023 11:38 AM GROSS LINE FAIL NOV 9, 2023 10:42 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:55 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:51 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:51 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:50 AM PLLD SHUTDOWN ALARM NOV 9, 2023 9:49 AM PLLD SHUTDOWN ALARM OCT 9, 2023 3:04 PM PLLD SHUTDOWN ALARM OCT 9, 2023 2:49 PM PLLD SHUTDOWN ALARM I30200 JAN 25, 2024 8:43 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 NOV 9, 2023 9:51 AM FUEL ALARM OCT 9, 2023 2:45 PM FUEL ALARM JUN 12, 2023 11:48 AM FUEL ALARM 2 DISP 1-2 ANN NOV 29, 2023 4:46 AM FUEL ALARM NOV 9, 2023 9:23 AM FUEL ALARM OCT 9, 2023 2:46 PM FUEL ALARM 3 DISP 3-4 NOV 9, 2023 9:49 AM FUEL ALARM OCT 9, 2023 2:44 PM FUEL ALARM JUN 12, 2023 1:38 PM FUEL ALARM 4 DISP 3-4 ANN NOV 9, 2023 9:20 AM FUEL ALARM OCT 9, 2023 2:45 PM FUEL ALARM JUN 12, 2023 1:38 PM FUEL ALARM 5 DISP 5-6 NOV 9, 2023 9:51 AM FUEL ALARM OCT 9, 2023 2:43 PM FUEL ALARM OCT 9, 2023 9:43 AM FUEL ALARM 6 DISP 5-6 ANN JAN 16, 2024 9:03 AM FUEL ALARM JAN 15, 2024 3:12 PM FUEL ALARM JAN 15, 2024 11:17 AM FUEL ALARM 7 DISP 7-8 NOV 9, 2023 9:50 AM FUEL ALARM OCT 9, 2023 2:41 PM FUEL ALARM JUN 12, 2023 1:40 PM FUEL ALARM 8 DISP 7-8 ANN NOV 9, 2023 9:20 AM FUEL ALARM OCT 9, 2023 2:42 PM FUEL ALARM JUN 12, 2023 1:41 PM FUEL ALARM 9 91 STP NOV 9, 2023 9:53 AM FUEL ALARM OCT 9, 2023 2:46 PM FUEL ALARM OCT 9, 2023 9:39 AM FUEL ALARM 10 91 STP ANN JAN 25, 2024 8:42 AM FUEL ALARM JAN 9, 2024 12:03 PM FUEL ALARM JAN 2, 2024 9:16 AM FUEL ALARM 11 91 FILL JAN 3, 2024 3:24 AM FUEL ALARM NOV 9, 2023 9:53 AM FUEL ALARM OCT 9, 2023 2:47 PM FUEL ALARM 12 91 FILL ANN NOV 9, 2023 9:30 AM FUEL ALARM OCT 9, 2023 2:47 PM FUEL ALARM JUN 12, 2023 11:44 AM FUEL ALARM 13 87 STP NOV 9, 2023 9:54 AM FUEL ALARM OCT 9, 2023 2:48 PM FUEL ALARM JUN 12, 2023 11:42 AM FUEL ALARM 14 87 STP ANN JAN 2, 2024 9:19 AM FUEL ALARM NOV 29, 2023 5:16 AM FUEL ALARM NOV 9, 2023 9:38 AM FUEL ALARM 15 87 FILL JAN 2, 2024 11:53 AM FUEL ALARM NOV 9, 2023 9:54 AM FUEL ALARM OCT 9, 2023 2:48 PM FUEL ALARM 16 87 FILL ANN JAN 9, 2024 1:16 PM FUEL ALARM JAN 3, 2024 9:02 AM FUEL ALARM JAN 2, 2024 1:02 PM FUEL ALARM 17 DIESEL STP NOV 9, 2023 9:55 AM FUEL ALARM OCT 9, 2023 2:49 PM FUEL ALARM JUN 12, 2023 11:15 AM FUEL ALARM 18 DSL STP ANN NOV 28, 2023 9:54 AM FUEL ALARM NOV 9, 2023 9:32 AM FUEL ALARM OCT 9, 2023 2:49 PM FUEL ALARM 19 DIESEL FILL NOV 9, 2023 9:55 AM FUEL ALARM OCT 9, 2023 2:50 PM FUEL ALARM JUN 12, 2023 11:11 AM FUEL ALARM 20 DSL FILL ANN NOV 9, 2023 9:32 AM FUEL ALARM OCT 9, 2023 2:50 PM FUEL ALARM JUN 12, 2023 11:12 AM FUEL ALARM 21 VENT BOX ANN NOV 9, 2023 9:27 AM FUEL ALARM OCT 9, 2023 2:52 PM FUEL ALARM JUN 12, 2023 12:46 PM FUEL ALARM 22 VENT BOX NOV 9, 2023 9:52 AM FUEL ALARM OCT 9, 2023 2:52 PM FUEL ALARM JUN 12, 2023 1:45 PM FUEL ALARM I31600 JAN 25, 2024 8:44 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2FM 2 DISP 3-4FM 3 DISP 5-6FM 4 DISP 7-8FM 5 DISP 1-2PS 6 91 VACCUM PRODUCT JAN 9, 2024 10:01 AM HIGH LIQUID ALARM JAN 9, 2024 9:25 AM HIGH LIQUID ALARM JAN 9, 2024 9:03 AM HIGH LIQUID ALARM 7 TANK ANN JAN 9, 2024 11:17 AM NO VACUUM ALARM JAN 9, 2024 10:55 AM NO VACUUM ALARM JAN 9, 2024 10:34 AM NO VACUUM ALARM 8 91 VACCUM VENT JAN 9, 2024 10:01 AM HIGH LIQUID ALARM JAN 9, 2024 9:31 AM NO VACUUM ALARM JAN 9, 2024 9:25 AM HIGH LIQUID ALARM 9 87 VACCUM PRODUCT JAN 9, 2024 9:01 AM HIGH LIQUID ALARM DEC 28, 2023 12:28 PM HIGH LIQUID ALARM DEC 28, 2023 10:07 AM HIGH LIQUID ALARM 10 87 VACCUM VENT JAN 9, 2024 9:01 AM HIGH LIQUID ALARM DEC 28, 2023 12:28 PM HIGH LIQUID ALARM DEC 28, 2023 10:07 AM HIGH LIQUID ALARM 11 87 VACCUM VAPOR JAN 9, 2024 9:01 AM HIGH LIQUID ALARM DEC 28, 2023 12:28 PM HIGH LIQUID ALARM NOV 9, 2023 11:07 AM NO VACUUM ALARM 12 DIESEL VACCUM PRODUC JAN 9, 2024 8:24 AM COMMUNICATION ALARM NOV 9, 2023 10:42 AM HIGH LIQUID ALARM NOV 9, 2023 10:42 AM NO VACUUM ALARM 13 DIESEL VACCUM VENT NOV 9, 2023 10:42 AM HIGH LIQUID ALARM NOV 9, 2023 10:42 AM NO VACUUM ALARM OCT 9, 2023 3:04 PM HIGH LIQUID ALARM 16 ATM P SENSOR I40200 JAN 25, 2024 8:44 AM I40300 JAN 25, 2024 8:44 AM I34200 JAN 25, 2024 8:44 AM I34700 JAN 25, 2024 8:44 AM IV0100 JAN 25, 2024 8:44 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-10-18 00:01:24 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 23-10-17 00:01:32 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.54 23-05-04 00:03:16 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.95 23-05-03 00:02:54 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.77 23-04-24 00:05:36 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.88 23-04-23 00:05:19 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.29 23-04-22 00:04:37 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.20 23-04-16 00:04:20 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.99 23-04-15 00:03:38 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.96 23-04-14 00:03:46 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.30 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-20 00:00:09 SENSOR OUT SELFTEST s 1 23-03-19 00:02:37 SENSOR OUT SELFTEST s 1 23-03-18 00:02:55 SENSOR OUT SELFTEST s 1 23-03-17 00:02:45 SENSOR OUT SELFTEST s 1 23-03-16 00:02:33 SENSOR OUT SELFTEST s 1 23-03-15 00:02:40 SENSOR OUT SELFTEST s 1 23-03-14 00:03:01 SENSOR OUT SELFTEST s 1 23-03-13 00:02:23 SENSOR OUT SELFTEST s 1 23-03-12 00:04:00 SENSOR OUT SELFTEST s 1 23-03-11 00:03:04 SENSOR OUT SELFTEST s 1 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-11-17 00:01:34 READINESS ISD:PP EVR:PP ISD & EVR READY 23-11-16 06:08:35 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-11-16 06:08:35 ISD STARTUP 23-11-15 20:54:21 ISD SHUTDOWN 23-11-10 00:03:05 READINESS ISD:PP EVR:PP ISD & EVR READY 23-11-09 16:31:53 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-11-09 16:31:53 ISD STARTUP 23-11-09 16:31:42 ISD SHUTDOWN 23-11-09 08:32:00 TIME CHANGE DETECTED AT: 23-11-09 09:33:00 23-10-18 04:10:02 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED Post Alarm History Responses Received: I10200 JAN 25, 2024 11:15 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 9521986 9804044 2 4 PROBE / G.T. 161602 161771 3 INTERSTITIAL BD 200073 200156 4 INTERSTITIAL BD 199932 200017 5 INTERSTITIAL BD 200543 200597 6 PLLD SENSOR BD 3893 3895 7 8SMARTSENSOR BD 39113 39122 8 7SMARTSENSOR BD 505316 505611 9 RELAY BOARD 14916 14940 10 PLLD POWER BD 100056 99469 11 UNUSED 9491041 9688914 12 UNUSED 9471690 9659864 13 UNUSED 9473988 9657882 14 UNUSED 9467252 9653404 15 UNUSED 9471826 9652179 16 UNUSED 9472952 9649840 COMM 1 ELEC DISP INT. 100447 100447 COMM 2 RS232 SERIAL BD 14984 15007 COMM 3 UNUSED 9481873 9661981 COMM 4 UNUSED 9467951 9653671 COMM 5 UNUSED 9465856 9647879 COMM 6 UNUSED 9465000 9647835 I90200 JAN 25, 2024 11:15 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JAN 25, 2024 11:15 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME Q 1 OTHER REGULAR UNL PLLD SHUTDOWN ALARM CLEAR 1-25-24 10:22AM Q 1 OTHER REGULAR UNL GROSS LINE FAIL CLEAR 1-25-24 10:22AM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM CLEAR 1-25-24 10:21AM L 6 DISP PAN DISP 5-6 ANN FUEL ALARM ALARM 1-25-24 10:21AM Q 1 OTHER REGULAR UNL PLLD SHUTDOWN ALARM ALARM 1-25-24 10:20AM Q 1 OTHER REGULAR UNL GROSS LINE FAIL ALARM 1-25-24 10:20AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM CLEAR 1-25-24 10:16AM Q 2 OTHER SUPER 91 GROSS LINE FAIL CLEAR 1-25-24 10:16AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM ALARM 1-25-24 10:15AM Q 2 OTHER SUPER 91 GROSS LINE FAIL ALARM 1-25-24 10:15AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 1-25-24 10:07AM Q 3 OTHER DIESEL GROSS LINE FAIL CLEAR 1-25-24 10:07AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 1-25-24 10:06AM Q 3 OTHER DIESEL GROSS LINE FAIL ALARM 1-25-24 10:06AM L 6 DISP PAN DISP 5-6 ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 2 DISP PAN DISP 1-2 ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 8 DISP PAN DISP 7-8 ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 1-25-24 9:49AM Q 2 OTHER SUPER 91 PLLD SHUTDOWN ALARM CLEAR 1-25-24 9:49AM Q 1 OTHER REGULAR UNL PLLD SHUTDOWN ALARM CLEAR 1-25-24 9:49AM L 7 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 5 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 4 DISP PAN DISP 3-4 ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 3 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L10 STP SUMP 91 STP ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L14 STP SUMP 87 STP ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L11 PIPE 91 FILL SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L 9 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L13 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L16 PIPE 87 FILL ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L15 PIPE 87 FILL SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L12 PIPE 91 FILL ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L18 STP SUMP DSL STP ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L17 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L22 DISP PAN VENT BOX SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L21 DISP PAN VENT BOX ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L20 PIPE DSL FILL ANN SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L19 PIPE DIESEL FILL SENSOR OUT ALARM CLEAR 1-25-24 9:49AM L10 STP SUMP 91 STP ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM L16 PIPE 87 FILL ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM L15 PIPE 87 FILL SENSOR OUT ALARM ALARM 1-25-24 9:48AM L 9 STP SUMP 91 STP SENSOR OUT ALARM ALARM 1-25-24 9:48AM L14 STP SUMP 87 STP ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM L13 STP SUMP 87 STP SENSOR OUT ALARM ALARM 1-25-24 9:48AM L12 PIPE 91 FILL ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM L11 PIPE 91 FILL SENSOR OUT ALARM ALARM 1-25-24 9:48AM L 6 DISP PAN DISP 5-6 ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM L 2 DISP PAN DISP 1-2 ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM L 8 DISP PAN DISP 7-8 ANN SENSOR OUT ALARM ALARM 1-25-24 9:48AM I11200 JAN 25, 2024 11:15 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 1-25-24 4:01AM SYSTEM PAPER OUT CLEAR 1-25-24 4:01AM SYSTEM PRINTER ERROR ALARM 1-25-24 3:52AM SYSTEM PAPER OUT ALARM 1-25-24 3:52AM SYSTEM PRINTER ERROR CLEAR 1-16-24 4:58PM SYSTEM PAPER OUT CLEAR 1-16-24 4:58PM SYSTEM PRINTER ERROR ALARM 1-16-24 4:57PM SYSTEM PAPER OUT ALARM 1-16-24 4:57PM SYSTEM PRINTER ERROR CLEAR 1-16-24 4:57PM SYSTEM PAPER OUT CLEAR 1-16-24 4:57PM SYSTEM PRINTER ERROR ALARM 1-16-24 4:57PM SYSTEM PAPER OUT ALARM 1-16-24 4:57PM SYSTEM PRINTER ERROR CLEAR 1-16-24 4:57PM SYSTEM PAPER OUT CLEAR 1-16-24 4:57PM SYSTEM PRINTER ERROR ALARM 1-16-24 4:57PM SYSTEM PAPER OUT ALARM 1-16-24 4:57PM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 1-05-24 8:44AM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 1-05-24 8:44AM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 12-11-23 5:40PM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 12-11-23 4:51PM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 12-08-23 9:45PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:39PM SYSTEM PAPER OUT CLEAR 12-08-23 7:39PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:38PM SYSTEM PAPER OUT ALARM 12-08-23 7:38PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:37PM SYSTEM PAPER OUT CLEAR 12-08-23 7:37PM SYSTEM PAPER OUT ALARM 12-08-23 7:37PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:37PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:36PM SYSTEM PAPER OUT CLEAR 12-08-23 7:36PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:36PM SYSTEM PAPER OUT ALARM 12-08-23 7:36PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:36PM SYSTEM PAPER OUT CLEAR 12-08-23 7:36PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:36PM SYSTEM PAPER OUT ALARM 12-08-23 7:36PM SYSTEM PRINTER ERROR CLEAR 12-08-23 7:36PM SYSTEM PAPER OUT CLEAR 12-08-23 7:36PM SYSTEM PRINTER ERROR ALARM 12-08-23 7:35PM SYSTEM PAPER OUT ALARM 12-08-23 7:35PM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 12-08-23 6:16PM T 1 TANK REGULAR 87 DELIVERY NEEDED CLEAR 11-28-23 7:46AM T 1 TANK REGULAR 87 DELIVERY NEEDED ALARM 11-27-23 3:16PM SYSTEM PRINTER ERROR CLEAR 11-09-23 10:46AM SYSTEM PAPER OUT CLEAR 11-09-23 10:46AM SYSTEM PRINTER ERROR ALARM 11-09-23 10:45AM SYSTEM PAPER OUT ALARM 11-09-23 10:45AM SYSTEM PRINTER ERROR CLEAR 11-01-23 4:03AM SYSTEM PRINTER ERROR ALARM 11-01-23 4:03AM I20600 JAN 25, 2024 11:15 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 TANK ALARM HISTORY TANK 1 REGULAR 87 HIGH WATER ALARM MAY 17, 2023 5:10 PM MAY 13, 2023 9:00 PM LOW PRODUCT ALARM NOV 28, 2023 7:31 AM AUG 10, 2023 6:20 PM MAY 13, 2023 3:26 PM PROBE OUT JAN 5, 2024 8:45 AM HIGH WATER WARNING MAY 17, 2023 5:10 PM MAY 13, 2023 9:00 PM DELIVERY NEEDED JAN 5, 2024 8:44 AM DEC 11, 2023 4:51 PM DEC 8, 2023 6:16 PM TANK 2 SUPER 91 OVERFILL ALARM OCT 9, 2023 7:03 PM HIGH PRODUCT ALARM OCT 9, 2023 7:06 PM TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JAN 25, 2024 11:15 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:REGULAR UNL JAN 25, 2024 10:20 AM PLLD SHUTDOWN ALARM JAN 25, 2024 10:20 AM GROSS LINE FAIL JAN 25, 2024 9:48 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:36 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:25 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:24 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:23 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:22 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:16 AM PLLD SHUTDOWN ALARM JAN 9, 2024 9:01 AM PLLD SHUTDOWN ALARM Q 2:SUPER 91 JAN 25, 2024 10:15 AM PLLD SHUTDOWN ALARM JAN 25, 2024 10:15 AM GROSS LINE FAIL JAN 25, 2024 9:48 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:30 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:25 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:24 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:23 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:22 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:14 AM PLLD SHUTDOWN ALARM JAN 9, 2024 10:01 AM PLLD SHUTDOWN ALARM Q 3:DIESEL JAN 25, 2024 10:06 AM PLLD SHUTDOWN ALARM JAN 25, 2024 10:06 AM GROSS LINE FAIL JAN 25, 2024 9:47 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:40 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:25 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:24 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:23 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:22 AM PLLD SHUTDOWN ALARM JAN 25, 2024 9:20 AM PLLD SHUTDOWN ALARM NOV 9, 2023 11:38 AM PLLD SHUTDOWN ALARM I30200 JAN 25, 2024 11:15 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:22 AM FUEL ALARM NOV 9, 2023 9:51 AM FUEL ALARM 2 DISP 1-2 ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:23 AM FUEL ALARM NOV 29, 2023 4:46 AM FUEL ALARM 3 DISP 3-4 JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:23 AM FUEL ALARM NOV 9, 2023 9:49 AM FUEL ALARM 4 DISP 3-4 ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:23 AM FUEL ALARM NOV 9, 2023 9:20 AM FUEL ALARM 5 DISP 5-6 JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:25 AM FUEL ALARM NOV 9, 2023 9:51 AM FUEL ALARM 6 DISP 5-6 ANN JAN 25, 2024 10:21 AM FUEL ALARM JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:26 AM FUEL ALARM 7 DISP 7-8 JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:24 AM FUEL ALARM NOV 9, 2023 9:50 AM FUEL ALARM 8 DISP 7-8 ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:24 AM FUEL ALARM NOV 9, 2023 9:20 AM FUEL ALARM 9 91 STP JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:14 AM FUEL ALARM NOV 9, 2023 9:53 AM FUEL ALARM 10 91 STP ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:14 AM FUEL ALARM JAN 25, 2024 8:58 AM FUEL ALARM 11 91 FILL JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:15 AM FUEL ALARM JAN 25, 2024 8:47 AM FUEL ALARM 12 91 FILL ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:15 AM FUEL ALARM NOV 9, 2023 9:30 AM FUEL ALARM 13 87 STP JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:16 AM FUEL ALARM NOV 9, 2023 9:54 AM FUEL ALARM 14 87 STP ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:16 AM FUEL ALARM JAN 2, 2024 9:19 AM FUEL ALARM 15 87 FILL JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:18 AM FUEL ALARM JAN 2, 2024 11:53 AM FUEL ALARM 16 87 FILL ANN JAN 25, 2024 9:48 AM SENSOR OUT ALARM JAN 25, 2024 9:18 AM FUEL ALARM JAN 9, 2024 1:16 PM FUEL ALARM 17 DIESEL STP JAN 25, 2024 9:47 AM SENSOR OUT ALARM JAN 25, 2024 9:20 AM FUEL ALARM NOV 9, 2023 9:55 AM FUEL ALARM 18 DSL STP ANN JAN 25, 2024 9:47 AM SENSOR OUT ALARM JAN 25, 2024 9:20 AM FUEL ALARM NOV 28, 2023 9:54 AM FUEL ALARM 19 DIESEL FILL JAN 25, 2024 9:46 AM SENSOR OUT ALARM JAN 25, 2024 9:21 AM FUEL ALARM NOV 9, 2023 9:55 AM FUEL ALARM 20 DSL FILL ANN JAN 25, 2024 9:47 AM SENSOR OUT ALARM JAN 25, 2024 9:21 AM FUEL ALARM NOV 9, 2023 9:32 AM FUEL ALARM 21 VENT BOX ANN JAN 25, 2024 9:46 AM SENSOR OUT ALARM NOV 9, 2023 9:27 AM FUEL ALARM OCT 9, 2023 2:52 PM FUEL ALARM 22 VENT BOX JAN 25, 2024 9:47 AM SENSOR OUT ALARM NOV 9, 2023 9:52 AM FUEL ALARM OCT 9, 2023 2:52 PM FUEL ALARM I31600 JAN 25, 2024 11:16 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2FM 2 DISP 3-4FM 3 DISP 5-6FM 4 DISP 7-8FM 5 DISP 1-2PS 6 91 VACCUM PRODUCT JAN 25, 2024 9:31 AM NO VACUUM ALARM JAN 25, 2024 9:30 AM HIGH LIQUID ALARM JAN 9, 2024 10:01 AM HIGH LIQUID ALARM 7 TANK ANN JAN 25, 2024 9:32 AM NO VACUUM ALARM JAN 9, 2024 11:17 AM NO VACUUM ALARM JAN 9, 2024 10:55 AM NO VACUUM ALARM 8 91 VACCUM VENT JAN 25, 2024 9:30 AM HIGH LIQUID ALARM JAN 9, 2024 10:01 AM HIGH LIQUID ALARM JAN 9, 2024 9:31 AM NO VACUUM ALARM 9 87 VACCUM PRODUCT JAN 25, 2024 9:36 AM NO VACUUM ALARM JAN 25, 2024 9:36 AM HIGH LIQUID ALARM JAN 9, 2024 9:01 AM HIGH LIQUID ALARM 10 87 VACCUM VENT JAN 25, 2024 9:37 AM NO VACUUM ALARM JAN 25, 2024 9:36 AM HIGH LIQUID ALARM JAN 9, 2024 9:01 AM HIGH LIQUID ALARM 11 87 VACCUM VAPOR JAN 25, 2024 9:38 AM NO VACUUM ALARM JAN 25, 2024 9:36 AM HIGH LIQUID ALARM JAN 9, 2024 9:01 AM HIGH LIQUID ALARM 12 DIESEL VACCUM PRODUC JAN 25, 2024 9:40 AM NO VACUUM ALARM JAN 25, 2024 9:40 AM HIGH LIQUID ALARM JAN 9, 2024 8:24 AM COMMUNICATION ALARM 13 DIESEL VACCUM VENT JAN 25, 2024 9:41 AM NO VACUUM ALARM JAN 25, 2024 9:40 AM HIGH LIQUID ALARM NOV 9, 2023 10:42 AM HIGH LIQUID ALARM 16 ATM P SENSOR I40200 JAN 25, 2024 11:16 AM I40300 JAN 25, 2024 11:16 AM I34200 JAN 25, 2024 11:16 AM I34700 JAN 25, 2024 11:16 AM IV0100 JAN 25, 2024 11:16 AM SKYWAY GASOLINE 4199 UNION AVE BAKESFIEL CA,93305 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 23-10-18 00:01:24 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 23-10-17 00:01:32 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.54 23-05-04 00:03:16 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.95 23-05-03 00:02:54 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.77 23-04-24 00:05:36 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.88 23-04-23 00:05:19 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.29 23-04-22 00:04:37 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.20 23-04-16 00:04:20 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 14.99 23-04-15 00:03:38 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.96 23-04-14 00:03:46 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.30 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-03-20 00:00:09 SENSOR OUT SELFTEST s 1 23-03-19 00:02:37 SENSOR OUT SELFTEST s 1 23-03-18 00:02:55 SENSOR OUT SELFTEST s 1 23-03-17 00:02:45 SENSOR OUT SELFTEST s 1 23-03-16 00:02:33 SENSOR OUT SELFTEST s 1 23-03-15 00:02:40 SENSOR OUT SELFTEST s 1 23-03-14 00:03:01 SENSOR OUT SELFTEST s 1 23-03-13 00:02:23 SENSOR OUT SELFTEST s 1 23-03-12 00:04:00 SENSOR OUT SELFTEST s 1 23-03-11 00:03:04 SENSOR OUT SELFTEST s 1 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 23-11-17 00:01:34 READINESS ISD:PP EVR:PP ISD & EVR READY 23-11-16 06:08:35 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-11-16 06:08:35 ISD STARTUP 23-11-15 20:54:21 ISD SHUTDOWN 23-11-10 00:03:05 READINESS ISD:PP EVR:PP ISD & EVR READY 23-11-09 16:31:53 READINESS ISD:PP EVR:NN EVR READINESS PENDING 23-11-09 16:31:53 ISD STARTUP 23-11-09 16:31:42 ISD SHUTDOWN 23-11-09 08:32:00 TIME CHANGE DETECTED AT: 23-11-09 09:33:00 23-10-18 04:10:02 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED