Loading...
HomeMy WebLinkAboutSnappys UST AS-built 4-8-2024SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME:PROJECT:INSTALLATION OF:·2 MODERN WELDING 20K SPLIT USTRUL 15K / PUL 5KSPLIT DIESEL 8K /E85 12K·4 DISPENSERS·NEW CANOPY 42'X42'SNAPPY'SCOVER SHEETSHEET INDEX1)C1- COVER SHEET2)S1- SITE PLAN3)S2- SITE PLAN4)F1- FUELING PLAN5)D1- DISPENSER PLAN6)T1- TANK PLAN 17)T2 - TANK PLAN8)T3 - SUMP PLAN9)E1 - ELECTRICAL PLAN10)V1- VENT PLAN11)M1- MONITORING PLAN12)PL1 - PARTS LISTSCOPE OF WORK13210/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS 4 FIRE AB 3/28/24 JO (2) 3+1 DIESELDISPENSERS(2) 3+1 E-85DISPENSERSBOLLARDS TYPESOFILL BOLLARD WITH CONC.PARGE TOP SMOOTH ANDPAINTCONCRETE PAVEMENTTOP OF GRADECONCRETE FOOTING18" Ø X 36" SONOTUBE18"DIA6"3'-0" 6"2SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: SITE PLAN S1 1" = 10'10/10/2022 ------ RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS1001'2'794380-323794380-323794380-323794380-208794380-2083 FIRE AB JO 4 FIRE AB 3/28/24 JO SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: SITE PLAN S2 NONE 10/10/2022 ------ RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS 1235 FIRE AB 4/1/24 JO TEST PORT TO BEINSTALLED BETWEEN4 O'CLOCK AND 8O'CLOCK POSITION12" MINTYPICALPEA GRAVELBACKFILL (TYP)10"10"1(4 PIPE) 48" WIDE TRENCH(3 PIPE) 36" WIDE TRENCH(2 PIPE) 26" WIDE TRENCH16" WIDE TRENCH(1 PIPE)2"6"18" MIN MIN.10SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: FUELING PLAN F1 1" = 10'------RULPULDVVEE8510/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS 001'2'13 FIRE AB JO 4 FIRE AB 3/28/24 JO LEFT SIDE VIEWFRONT VIEWMINIMUM CONCRETE 6"TOP VIEW 3+1TOP VIEW 3+0BREAKAWAY12" WHIP HOSEBREAKAWAY12" WHIP HOSE8' HOSE8' HOSECHECK WITH CONSTRUCTIONMANAGER FOR OCTANE DECALARRANGEMENT AND PROPEROCTANES TO BE USED(MIDGRADEALWAYS TO BE AT CENTER.)CHECK WITH CONSTRUCTIONMANAGER FOR OCTANE DECALARRANGEMENT AND PROPEROCTANES TO BE USEDNOZZLELOWER PIPING CROSSBRACE PROVIDEDWITH DISPENSERSLOPE CONCREGULARMID-GRADEPREMIUMDIESEL NOZZLEDIESEL SWIVELDIESEL878991NOZZLEUNIONS AND PIPINGLOWER PIPING CROSSBRACE PROVIDEDWITH DISPENSERUNIONS ANDPIPING TYPSLOPE CONCVAPOR SHEAR VALVESHEAR VALVESPIPE CLAMPFLEX HOSEV15"3+0 DISPENSER3+1 DISPENSERCL5"10"VARIES PER FIELD CONDITIONP2" SCHED 40 BLACK IRONPIPING AND FITTINGSUTRIM SUMP AS REQUIRED FOR SITECONDITIONS AND PIPE SLOPES.RELOCATE RAIN-LIP AND EQUIPRAILS TO MAINTAIN A 2"PROJECTION ABOVE THE RAIN-LIPTRIM SUMP AS REQUIRED FORSITE CONDITIONS AND PIPE SLOPES.RELOCATE RAIN-LIP AND EQUIPRAILS TO MAINTAIN A 2" PROJECTIONABOVE THE RAIN-LIPUVDPVARIES PER FIELD CONDITION2" SCHED 40 BLACK IRONPIPING AND FITTINGS10"5"CL5"10"4'-0" MAX TO HIGHEST POINT OF FUNCTIONAL PART 4'-0" MAX TO HIGHEST POINT OF FUNCTIONAL PART ADA COMPLIANTCONTROL PANELADA COMPLIANTCONTROL PANELLEFT SIDE VIEWMINIMUM CONCRETE 6" SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME:DISPENSER PLAN10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS OFFSET CONSTRUCTIONCIRCUMFERENTIAL SEAMSDOUBLE BUTT CONSTRUCTIONLONGITUDINAL SEAMSGLASTEEL IIFIBERGLASSCOMPOSITETMSEPARATIONMATERIALANNULARSPACE120"IDSTEEL PRIMARY TANKGLASTEEL IITMCONSTRUCTION DETAILSINTERIOR: BARE, CLEAN OFDEBRISmodernEXTERIOR: F.R.P.MODERN WELDING COMPANYOF CALIFORNIATHIS TANK ARRIVES AT THE JOBSITE UNDERVACUUM AND DOES NOT REQUIRE FURTHERINTEGRITY TESTS. IF JOBSITE AIR PRESSURE TESTREQUIRED THE PRIMARY (INNER) TANK MAY BEPRESSURIZED UP TO 5 P.S.I. THE SECONDARY(OUTER) TANK MAY BE TESTED BY VACUUMONLY. THE OUTER TANK RECEIVES A 35,000VOLTS HOLIDAY TEST AT THE FACTORYmodernmodern welding companyof california, inc.4141 N. BRAWLEY AVE FRESNO, CA 93722PH. 559-275-9353 FAX 559-275-438120,000 GALLON GLASTEEL II JACKETED UNDERGROUND TANK9/13/171446612 "26" 8" 8" 7"8"8" 28"8"8"CLT1 SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: 10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS Regular(87)Premium(91) OFFSET CONSTRUCTIONCIRCUMFERENTIAL SEAMSDOUBLE BUTT CONSTRUCTIONLONGITUDINAL SEAMSGLASTEEL IIFIBERGLASSCOMPOSITETMSEPARATIONMATERIALANNULARSPACE120"IDSTEEL PRIMARY TANKGLASTEEL IITMCONSTRUCTION DETAILSINTERIOR: BARE, CLEAN OFDEBRISmodernEXTERIOR: F.R.P.MODERN WELDING COMPANYOF CALIFORNIATHIS TANK ARRIVES AT THE JOBSITE UNDERVACUUM AND DOES NOT REQUIRE FURTHERINTEGRITY TESTS. IF JOBSITE AIR PRESSURE TESTREQUIRED THE PRIMARY (INNER) TANK MAY BEPRESSURIZED UP TO 5 P.S.I. THE SECONDARY(OUTER) TANK MAY BE TESTED BY VACUUMONLY. THE OUTER TANK RECEIVES A 35,000VOLTS HOLIDAY TEST AT THE FACTORYmodernmodern welding companyof california, inc.4141 N. BRAWLEY AVE FRESNO, CA 93722PH. 559-275-9353 FAX 559-275-438120,000 GALLON GLASTEEL II JACKETED UNDERGROUND TANK9/13/17144668" 8"8" 8"CLCL12"T2 SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: 10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS E-85Diesel MECHANICAL LINE LEAK DETECTOR(FIGURE 2)PRODUCT LINECONDUIT AND LBY'S TOSTP POWER CONNECTIONCONDUIT FROM ELEC ROOMFOR STP POWER2" SCHED 40 GALVANIZEDPIPE FITTINGS FOR REGULARAND PREMIUM2" FRP X 33" LONG MIN(BEYOND) FOR SUMP SENSORHOUSING 1" CLR FROM TANKELEC SEAL-OFFULEXPLOSION PROOF J-BOX(FOR SENSORS)2" SCHED 40 GALV PIPE FITTINGSFOR REGULAR AND PREMIUMSTRIKE PLATESBY TANK MFRT KDW EIGHT SIDED SUMPCONDUIT FROM ANNULARSPACE MH FOR SENSOR4" SCHED 40 BLACK IRONPIPE RISERSUMP SENSOR BRACKETU-BOLTED TO PIPE RISER (2 LOC)PIPE CLAMPS, SENSOR BRACKETSAND U-BOLTSCONCRETE TANK SLAB20"FUEL PIPING TREE(BELOW DISCHARGE)CONDUIT AND LBY'S TOSTP POWER CONNECTIONEXPLOSION PROOFJ-BOX (FOR STP POWER)CONDUIT FROM ELEC ROOMFOR STP POWERSUMP SENSOR BRACKETU-BOLTED TO ATG RISER (2 LOC)PIPE CLAMPS, SENSOR BRACKETSAND U-BOLTSEXPLOSION PROOF J-BOX(FOR SENSORS)CONDUIT FROM ANNULAR SPACEMANHOLE FOR SENSORS2" FRP X 33" LONG MIN(BEYOND) FOR SUMP SENSORHOUSING 1" CLR FROM TANKEIGHT SIDED DWSUMP- SUPPLIED w/ TANK (TYP)ROTATE VIEW AS REQUIRED FOR FIELD CONDITIONPENETRATIONS INTO SUMP ARE SHOWN FORREFERENCE ONLYFILL/TURBINE SUMP SECTION6"4" SCHED 40 BLACKIRON PIPE RISERDW EIGHT SIDED SUMP3" SCHED 40 BLACK IRONPIPE AND FITTINGSEXPLOSION PROOFJ-BOX AND CABLE GLANDAS REQ'D FOR SENSORELEC SEAL-OFFCONDUIT FROM ANNULARSPACE MH FOR SENSOR4" SCHED 40 BLACK IRONPIPE RISERSUMP SENSOR BRACKETU-BOLTED TO PIPE RISER (2 LOC)PIPE CLAMPS, SENSOR BRACKETSAND U-BOLTS2" FRP X 33" LONG(MIN) FOR SUMP SENSORHOUSING 1" CLR FROM TANK12"x12" STRIKE PLATEBY TANK MFRCONCRETE TANK SLABVENTFILL SUMP SECTIONROTATE VIEW AS REQUIRED FOR FIELD CONDITIONREFERENCE ONLYVAPOR2" SCHED 40 GALVANIZEDPIPE AND FITTINGS FORREGULAR AND PREMIUM4" SCHED 40 BLACK IRON PIPERISER3" SCHED 40 BLACK IRONPIPE AND FITTINGSFITTING FOR VACUUMMONITORING4" SCHED 40 BLACK IRONPIPE RISEREXPLOSION PROOF J-BOX ANDCABLE GLAND AS REQUIREDCONDUIT FROM ANNULARSPACE MH FOR SENSOR2" FRP X 33" LONG(MIN) FOR SUMP SENSORHOUSINGSUMP SENSOR BRACKETU-BOLTED TO PIPE RISER (2 LOC)PIPE CLAMPS, SENSOR BRACKETSAND U-BOLTS20"4" 2"45°CONDUIT AND LBY'S TOSTP POWER CONNECTIONCONDUIT FROM ELEC ROOMFOR STP POWERDW SUMP SUPPLIEDw/ TANKS (TYP)2" SCHED 40 GALVANIZEDPIPE FITTINGS FOR REGULARAND PREMIUM2" FRP X 33" LONG MIN(BEYOND) FOR SUMP SENSORHOUSING 1" CLR FROM TANKEXPLOSION PROOFJ-BOX TYP (POWER)ELEC SEAL-OFFUL CONCRETE TANK SLABWATERTIGHT COVER WITHOBSERVATION PORTALIGN PORT WITH ATGTRIM MH SKIRT TO MAINTAIN2" TO 4" BETWEEN SUMPSECURE FOAM PIPE INSULATIONTO BOTTOM OF MH SKIRTEXPLOSION PROOF J-BOX(FOR SENSORS)2" SCHED 40 GALV PIPE FITTINGSFOR REGULAR AND PREMIUMELEC SEAL-OFFFUEL PIPING TREESUMP SENSOR BRACKETU-BOLTED TO ATG RISER (2 LOC)PIPE CLAMPS, SENSOR BRACKETSAND U-BOLTSCONDUIT FROM ANNULAR SPACEMANHOLE FOR SENSORSSTRIKE PLATESBY TANK MFRTURBINE SUMP SECTIONFUEL PIPING TREE(BELOW DISCHARGE)CONDUIT AND LBY'S TOSTP POWER CONNECTIONEXPLOSION PROOFJ-BOX (FOR STP POWER)CONDUIT FROM ELEC ROOMFOR STP POWERROTATE VIEW AS REQUIRED FOR FIELD CONDITIONREFERENCE ONLYSUMP SENSOR BRACKETU-BOLTED TO ATG RISER (2 LOC)PIPE CLAMPS, SENSOR BRACKETSAND U-BOLTSEXPLOSION PROOF J-BOX(FOR SENSORS)CONDUIT FROM ANNULAR SPACEMANHOLE FOR SENSORS2" FRP X 33" LONG MIN(BEYOND) FOR SUMP SENSORHOUSING 1" CLR FROM TANKEIGHT SIDED DWSUMP- SUPPLIED w/ TANK (TYP)6" T KPENETRATIONS INTO SUMP ARE SHOWN FORPENETRATIONS INTO SUMP ARE SHOWN FORUPPER SUMP WALLFOAM FORMFOAM FORM3 MAT LAY-UPINSIDE & OUTSIDEUPPER SUMP WALLADHESIVE3 MAT LAY-UPINSIDE & OUTSIDE3 MAT LAY-UPINSIDE & OUTSIDEANNULAR SPACEOUTER WALLLAY-UP OVERFORM 6" WIDEM M M 360 DEGREECOLLARLAY-UP OVER FORM6"WIDE M M M360 DEGREELOWER SUMP WALLINNER WALLLOWER SUMP WALLLAY-UP OVER FORM10"WIDE M M M360 DEGREELOWER SUMP WALLPIPE RISERSUMP SENSOR BRACKETU-BOLTED TO PIPE RISER(2 LOC) PIPE CLAMPS,SENSOR BRACKETSAND U-BOLTS2" FRP X 33" LONG(MIN) FOR SUMP SENSORHOUSING 1" CLR FROM TANKLAY-UP SAMPLES SHOWN ARE FOR REFERENCE ONLY. REFER TO MANUFACTURER'SINSTALLATION INSTRUCTIONS FOR SPECIFIC LAY-UP MATERIALS AND METHODS.1"10' DIA UNDERGROUND STORAGE TANK SECTIONPEA GRAVEL BACKFILL (TYP)12" PEA GRAVEL BACKFILLUNDER TANKS (TYP)PRODUCT LINEAUTOMATIC TANK GAUGING PROBEAUTOMATIC TANK GAUGING PROBEFILL SUMP (TYP)TURBINE SUMP (TYP)COMBINED FILL/TURBINE SUMP (TYP)SUMP SENSOR ANDSENSOR BRACKET DETAILTANK SUMP LAYUP DETAILSLINE LEAK DETECTOR DETAILTANK SYPHON TURBINE (STP)5 GALLON VAPORBUCKET P761C-FLPL5 GALLON FILLBUCKET P761C-FLDVDROP TUBE W/ FLAPPEROVERFILL PREVENTION DEVICEVEEDER-ROOT SENSOR794380-208VEEDER-ROOT SENSOR794380-208VEEDER-ROOT SENSOR794380-208VAPORLESS LEAK DETECTOR99-LD2000FG300-MQM-15NOV FITTING 012030-626-0SUMP PENETRATION (TYP)FG200-QMF-182"X18" (TYP)ELECTRICAL PENETRATIONBRAVO FRP DW F-07RS-0-DFNOV FITTING 012030-626-0SUMP PENETRATION (TYP) 2" BALL VALVE (TYP)MORRISON 691-08001VATGOPW FL100TOP DOWN VIEWELECTRICAL PENETRATIONBRAVO FRP DW F-07RS-0-DFELECTRICAL PENETRATIONBRAVO FRP DW F-07RS-0-DFNOV FITTING 012030-626-0SUMP PENETRATION (TYP)DROPTUBE WITH OVERFILL DEVICETURBINE (STP)UST SUMP PLANT-3 NONE N/A SUMP PLAN SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME:STP-MLD+ VentTube connected totank port10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS VACUUM KIT SEE M1MOUNTED TO ATG RISERVACUUM KIT SEE M1MOUNTED TO ATG RISER EMT CONDUITSIZE AND QUANTITY OF CONDUITS ARE FOR REFERENCE ONLY.ELECTRICALROOM(ACTUAL LAYOUT MAY VARY TO MEET SITE CONDITIONS)MAGVFC3 POLE 100 ACONTACTORSTPCBSMAGVFCMAGVFCEMSCP-1WIRE WAYEXISTINGSTOREPANELNEWPANELFSTPIRTYP 6STPIRDBOXSTPIRSTPIRLow VoltageWIRE WAYWIRE WAYWIRE WAYWIRE WAYFLOORSTPIRSTPIRDispenser Wiring D isconnect Low VoltageDispenser W iring DisconnectTO SALESCOUNTERPOWE R IN TEG RI TY™ Po we r I nt eg r it y Co rp o ra ti on G re en sb or o, N .C . NFPA a nd NE C a re re g is te r ed t ra de ma rk s o f th e N at i on a l F ir e P ro t ec t i on A s so ci a t io n POWER INT EGR ITY™ P ow er In te gr i ty C or po ra t io n Gr ee ns bo ro , N .C .NFPA a nd N EC ar e r eg i s te re d tr ad em a rk s o f t h e Na t io na l Fi r e P ro t ec t io n A ss oc i a ti onGUTTER LOOPSTO E-STOP(S)DISPENSER POWERSTP POWERSENSORSTO VEEDER ROOT TO EDH DISPENSER DATAINTERCOM1'-6" 1'-6" 1'-6"ATYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(UNDERGROUND TANK - FILL OPENING)EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH ISWITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION.EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:1'-6"BCLASS 1, DIV. 2 F(TYP.)E CLASS 1, DIV. 1(TYP.)G CLASS 1, DIV. 220' RADIAL (TYP.)DIESE L REGULAR M I D- G RA D E P R EM I UM DIESEL REGUL A R M I D -G R AD E PR EM I U MCRRUP TO 18 INCHES ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUSOF 10 FEET FROM A LOOSE FILL CONNECTION AND WITHIN AHORIZONTAL RADIUS OF 5 FEET FROM A TIGHT FILL CONNECTION.TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(UNDERGROUND TANK - VENT DISCHARGING UPWARD)EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:WITHIN 5 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS.EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:SPACE BETWEEN 5 FEET AND 10 FEET OF OPEN END OF VENT,EXTENDING IN ALL DIRECTIONS.TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(REMOTE PUMP - OUTDOOR)EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL IF ANY PART IS WITHIN AHORIZONTAL DISTANCE OF 10 FEET FROM ANY EDGE OF PUMP.20'-0"EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:D CLASS 1, DIV. 1. TYPICAL,SUMPS UNDER DISPENSERS (TYP.)WITHIN 3 FEET OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTION.ALSO UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEETHORIZONTALLY FROM ANY EDGE OF PUMP.HEXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OFANY EDGE OF ENCLOSURE.TYPICAL N.E.C. ARTICLE 514 CLASS 2 LOCATION(VAPOR PROCESSING SYSTEM)EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:UP TO 18 INCHES OF EQUIPMENT EXTENDING HORIZONTALLY IN ALLDIRECTIONS OF ANY EDGE OF EQUIPMENT DOWN TO GRADE LEVEL. UP TO18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET HORIZONTALLY OF ANYEDGE OF EQUIPMENT.GFEDTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(DISPENSING DEVICE - PITS)EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH ISWITHIN THE DIVISION 1 OR 2 CLASSIFICATION LOCATION.TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(DISPENSING DEVICE - DISPENSER)EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVEREDIN ANSI/UL 87, "POWER OPERATED DISPENSING DEVICES FOR PETROLEUMPRODUCTS."TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(DISPENSING DEVICE - DISPENSER)EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TOGRADE FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OFTHE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLINGCOMPONENTS. SPACE CLASSIFICATION INSIDE THE DISPENSERENCLOSURE IS COVERED IN ANSI/UL 87, "POWER OPERATED DISPENSINGDEVICES FOR PETROLEUM PRODUCTS."TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION(DISPENSING DEVICE - OUTDOOR)1'-6"ECLASS 1, DIV. 2 F(TYP.)CLASS 1, DIV. 1(TYP.)20'-0"G CLASS 1, DIV. 220' RADIAL (TYP.)20'-0"D CLASS 1, DIV. 1. TYPICAL,SUMPS UNDER DISPENSERS(TYP.)CLASS 1, DIV. 1 B5' RADIAL FROMVENT OUTLETREMOTE VENT AND CLEAN AIRSEPARATOR LOCATIONS WILLVARY WITH TANK LOCATION.SEE SITE SPECIFIC DRAWINGSFOR EXACT TANK LOCATION AND SHEETG0.1 FOR LOCATION OF CLEAN AIRSEPARATOR AND VENT RISERS (TYP.)CLASS 1, DIV. 210' RADIAL FROMVENT OUTLETHCLASS 1, DIV. 2 10'PERIMETER FROMVAPOR TANKB10'-0"D CLASS 1, DIV. 1. TYPICAL,SUMP UNDER VENT RISER(SS/PM) - SMART SENSOR/PRESSURE MODULE(ISIM)(P/TIM)- INTERSTITIAL SENSOR INTERFACE MODULE- PROBE/THERMISTOR INTERFACE MODULEOUTER CABLE JACKETAC LINEAC NEUTRALCHASSIS GROUNDBARRIER GROUNDROBROY RIGIDPVC COATEDCONDUITNON-HAZARDOUS AREACONTINUE TOOTHER DISPENSERSWEATHER/EXPLOSIONPROOF JUNCTION BOXES-N LFUSE794380-208ISD PRESSURESENSOR ONLY ATDIPENSER SUMP 1+EPOXY SEALANT-330020-315+1. INTRINSICALLY SAFE WIRINGEthernet/Phone lineCommunicationsCompartment-330020-445+-794380-208+WEATHERROBROY RIGIDPVC COATEDCONDUITEXPLOSION PROOFJUNCTION BOXESTERMINATION POINTS FORSHIELDED CABLETANK SUMP #5 (TANK #6 SIM BUT NOT SHOWN)TCP/IP TOPROCURVESWITCHBIR CABLE TO EDHGAS CONTROLLERLIQUID SENSOR ATTURBINE SUMP(ISIM)794380-303-VACFLOATVAC+VACVENT(SS/PM)FLOATVACSENSOR+VACPRODUCT(SS/PM)FLOATVACSENSOR+VACTURBINE FILLSUMP(SS/PM)FLOATVACSENSOR846390-107+(P/TIM)846390-107TABLE 1CABLE TYPEBELDEN 8876012 AWG THWNWIRE TYPES AND SIZESPROBE OR SENSORPROBE, SUMP, LIQUID, AND VACUUM SENSORAC POWER TO CONSOLEPUMP LOOP #2 TO D. BOX 17-32 MPDS. CAT. 6PUMP LOOP #1 TO D. BOX 4-16 MPDS. CAT. 6ETHERNETCONNECTIONGILBARCOROUTERCISCORV1042PASSPORTPOWERED BYCYBERACAT. 6 FROM GILBARCOROUTER TO RIS JUNIPERROUTER.SRK/JUNIPER (4 CABLESFROM JUNIPER) GOT, GOTEXTRA AND 2 SPARES-(P/TIM)ENHANCEDDISPENSER HUBPORT #4 PRICE SIGN CONTROLLERPORT #3 PIN PAD #3PORT #2 PIN PAD #2PORT #1 PIN PAD #1UNUSED PUMP LOOPS-VACFLOATVACSENSORVAPOR AND UDC(SS/PM)PORT #6 CAR WASHIDG RECEPTACLE FOREDH AND SURGESUPPRESSOR-VACFLOATVACSENSORTANK SUMPS(SS/PM)SURGE SUPPRESSORRJ45 ENDS W/ 7-ELEVENKIT AND GENDERMENDER CONNECTORS.1" CONDUIT WITH 4 CAT.6CABLES FROM COUNTERTO BACKROOM, TANKMONITOR D.BOX AND WORKSTATION RIS ROUTERPORT #5 TANK MONITORCAT. 6NOTE: IN EXISTING STORES, VERIFYTHE EXISTENCE OF A CAT6 CABLEWITH RJ45 CONNECTORS ON EACHEND OF THE CABLE AS THECONNECTION FROM THEAUTOMATIC TANK MONITOR (ATG)TO THE IN STORE PROCESS OR (ISP).SENSORPRODUCT(SS/PM)2. EDH, D-BOX, CRIND CONTROL CABLE, GAS CONTROLLER CABLEAND D-BOX CABLE INSTALLED BY THE GILBARCO AUTHORIZEDSERVICE CONTRACTORRECEPTACLE+(ISIM)794380-208HYDOSTATIC SENSOR ATTANK ANNULAR+NOTE:1. HUB, ROUTER AND CABLES BY NCR INSTALLERGASOLINE DISPENSERDATA DISCONNECTDEVICE-(ISIM)794380-303HYDOSTATIC SENSOR ATTANK ANNULARUPSD-BOX794380-208LIQUID SENSOR ATFILL SUMP+(ISIM)794380-208-(ISIM)PORT 6TO FRAME RELAYTELEPHONE LINEPUMP LOOPS1-4 AS REQUIREDLIQUID SENSOR ATTURBINE SUMP-(ISIM)794380-208JUNIPERROUTERCISCOROUTERVPNEDHTANK SUMP #4LIQUID SENSOR ATFILL SUMPCATEGORY 6CABLECATEGORY 6CABLELANCATEGORY 6CABLECATEGORY 6CABLEDATAPAIRED GASOLINECABLE IN TRENCHTO GASOLINEDISPENSERSCARWASHPINPAD1LIQUID SENSORAT VENT SUMP(ISIM)CATEGORY 6CABLEATGPRICESIGNPINPAD3PINPAD2CATEGORY 6CABLEISD FLOW METERSENSOR ATDIPENSER SUMP(SS/PM)BONDED CONDUIT MEANS THAT THE METALLICSECTIONS OF CONDUIT ARE PERMANENTLYJOINED TO FORM AN ELECTRICALLYCONDUCTIVE PATH THAT WILL ASSUREELECTRICAL CONTINUITY, AND THAT THECONDUIT HAS THE CAPACITY TO CONDUCTSAFELY, ANY CURRENT LIKELY TO BE IMPOSED.a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ervices3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME:ELECTRICAL PLAN10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS 12SHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: 10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS MONITORING PLANM-1 NONE N/A MONITORING PLANMONITORING PLANSHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: 10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS MONITORING PLANPL-1 NONE N/A PARTS LISTPARTS LISTSHEET NUMBER:LC Services3887 N. Valentine Ave.Fresno, Ca. 93722CA Lic.# 779267NV Lic.# 77063Larry R. CarpenterSHEET NAME: 10/10/2022 RANI ALHABROUN 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 3601 STOCKDALE HWY BAKERSFIELD, CA 93309 SNAPPYS