HomeMy WebLinkAboutFMC 2024Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10129798 04/18/24 Panama-Buena Vista USD 4200 Ashe Road Bakersfield 93313 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/25 Veeder Root - C33847 07/24/25 Vaporless Manufacturing LLC #5346 03/14/25 04/18/24 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS350 334.01 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 420 Unleaded Annular L2 208 Unleaded STP Sump L3 420 Diesel Annular L4 208 Diesel STP Sump L5 208 Dispenser 1/2 L6 208 Dispenser 3/4 L7 420 Waste Oil Annular Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 Unleaded T2 FX1DV Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Panama-Buena Vista USD4200 Ashe RoadBakersfield101297983/4Diesel871/2ProductProductMark Fisher Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10129798 04/18/24 Panama-Buena Vista USD 4200 Ashe Road Bakersfield 93313 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/25 OPW - 1193587 08/04/25 PEI1200, 1 hour hydrostatic test All Spill Buckets 04/18/24 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. 87 OPW Diesel OPW PANAMA BUENA VISTA USD SYSTEM SETUP Responses Received: 200 PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA APR 18, 2024 9:20 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 DIESEL 2800 26.72 0.0 69.2 9353 2 UNLEADED 2755 26.41 0.0 71.9 9398 3 WASTE OIL 250 21.38 4.0 70.5 300 I90500 APR 18, 2024 9:20 AM SOFTWARE REVISION LEVEL VERSION 334.01 SOFTWARE# 346334-100-B CREATED - 17.01.09.16.10 NO SOFTWARE MODULE SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS I50500 APR 18, 2024 9:20 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 APR 18, 2024 9:20 AM SHIFT TIME 1 : 1:00 AM I50202 APR 18, 2024 9:20 AM SHIFT TIME 2 : DISABLED I50203 APR 18, 2024 9:20 AM SHIFT TIME 3 : DISABLED I50204 APR 18, 2024 9:20 AM SHIFT TIME 4 : DISABLED I54600 APR 18, 2024 9:20 AM TANK PER TST NEEDED WRN: DISABLED I54900 APR 18, 2024 9:20 AM TANK ANN TST NEEDED WRN: DISABLED I55300 APR 18, 2024 9:20 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 APR 18, 2024 9:20 AM LINE PER TST NEEDED WRN: DISABLED I55900 APR 18, 2024 9:20 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 APR 18, 2024 9:20 AM PRINT TC VOLUMES ENABLED I50E00 APR 18, 2024 9:20 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 APR 18, 2024 9:20 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 APR 18, 2024 9:20 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 APR 18, 2024 9:20 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 APR 18, 2024 9:20 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 APR 18, 2024 9:20 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 APR 18, 2024 9:20 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 APR 18, 2024 9:20 AM TANK CHART SECURITY DISABLED I5BD00 APR 18, 2024 9:20 AM CUSTOM ALARM LABELS DISABLED I56000 APR 18, 2024 9:20 AM MASS/DENSITY DISABLED I88101 APR 18, 2024 9:20 AM I88102 APR 18, 2024 9:20 AM I88103 APR 18, 2024 9:20 AM I88104 APR 18, 2024 9:20 AM I88105 APR 18, 2024 9:21 AM PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 2400 PARITY : EVEN STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88106 APR 18, 2024 9:21 AM PORT SETTINGS: COMM BOARD : 6 (RS-232) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I52000 APR 18, 2024 9:21 AM I60100 APR 18, 2024 9:21 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL ON 2 UNLEADED ON 3 WASTE OIL ON 4 OFF I60200 APR 18, 2024 9:21 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL 2 UNLEADED 3 WASTE OIL 4 I60300 APR 18, 2024 9:21 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL 1 2 UNLEADED 2 3 WASTE OIL 3 4 4 I60900 APR 18, 2024 9:21 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL 0.000450 2 UNLEADED 0.000700 3 WASTE OIL 0.000470 4 0.000000 I60700 APR 18, 2024 9:21 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL 95.00 2 UNLEADED 95.00 3 WASTE OIL 46.00 4 0.00 I60A00 APR 18, 2024 9:21 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 DIESEL 20 PTS 12153 2 UNLEADED 20 PTS 12153 3 WASTE OIL 1 PT 550 4 1 PT 0 I60400 APR 18, 2024 9:21 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 12153 2 UNLEADED 12153 3 WASTE OIL 550 4 0 I60500 APR 18, 2024 9:21 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 DIESEL 12153 9770 6076 2368 2 UNLEADED 12153 9770 6076 2368 3 WASTE OIL 550 0 0 0 4 0 0 0 0 I60600 APR 18, 2024 9:21 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 DIESEL 12153 11928 11520 11016 10423 9770 9087 8355 7614 6841 6076 5295 4539 3782 3066 2368 1730 1136 633 224 2 UNLEADED 12153 11928 11520 11016 10423 9770 9087 8355 7614 6841 6076 5295 4539 3782 3066 2368 1730 1136 633 224 3 WASTE OIL 550 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 APR 18, 2024 9:21 AM TANK PRODUCT LABEL METER DATA 1 DIESEL NO 2 UNLEADED NO 3 WASTE OIL NO 4 NO I62F00 APR 18, 2024 9:21 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 DIESEL 4.0 IN. 2 UNLEADED 4.0 IN. 3 WASTE OIL 4.0 IN. I62700 APR 18, 2024 9:21 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL 4.0 2 UNLEADED 4.0 3 WASTE OIL 5.0 I64200 APR 18, 2024 9:21 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 DIESEL LOW 2 UNLEADED LOW 3 WASTE OIL LOW I62400 APR 18, 2024 9:21 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL 5.0 2 UNLEADED 5.0 3 WASTE OIL 5.0 I62800 APR 18, 2024 9:21 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 12153 2 UNLEADED 12153 3 WASTE OIL 550 4 0 I62300 APR 18, 2024 9:21 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 10938 2 UNLEADED 10938 3 WASTE OIL 495 4 0 I62200 APR 18, 2024 9:21 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 11545 2 UNLEADED 11545 3 WASTE OIL 523 4 0 I62900 APR 18, 2024 9:21 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 1215 2 UNLEADED 1215 3 WASTE OIL 6 4 0 I62100 APR 18, 2024 9:22 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 1000 2 UNLEADED 1000 3 WASTE OIL 1 4 0 I62600 APR 18, 2024 9:22 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 50 2 UNLEADED 50 3 WASTE OIL 99 4 99 I62500 APR 18, 2024 9:22 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 50 2 UNLEADED 50 3 WASTE OIL 99 4 99 I60800 APR 18, 2024 9:22 AM TANK TILT TANK PRODUCT LABEL INCHES 1 DIESEL 0.25 2 UNLEADED 1.25 3 WASTE OIL 0.00 4 0.00 I60B00 APR 18, 2024 9:22 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 APR 18, 2024 9:22 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 DIESEL 0.00 2 UNLEADED 0.00 3 WASTE OIL 0.00 4 0.00 I61200 APR 18, 2024 9:22 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 DIESEL NONE NONE 2 UNLEADED NONE NONE 3 WASTE OIL NONE NONE 4 NONE NONE I63600 APR 18, 2024 9:22 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 4010 2 UNLEADED 4010 3 WASTE OIL 0 4 0 I62A00 APR 18, 2024 9:22 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 6076 2 UNLEADED 6076 3 WASTE OIL 0 4 0 I62C00 APR 18, 2024 9:22 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 DIESEL STANDARD 2 UNLEADED STANDARD 3 WASTE OIL STANDARD 4 STANDARD I62D00 APR 18, 2024 9:22 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 WASTE OIL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 APR 18, 2024 9:22 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 DIESEL OFF OFF 2 UNLEADED OFF OFF 3 WASTE OIL OFF OFF 4 OFF OFF I63000 APR 18, 2024 9:22 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 DIESEL OFF 2 UNLEADED OFF 3 WASTE OIL OFF 4 OFF I63200 APR 18, 2024 9:22 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 DIESEL OFF 2 UNLEADED OFF 3 WASTE OIL OFF 4 OFF I61000 APR 18, 2024 9:22 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 DIESEL 3 2 UNLEADED 3 3 WASTE OIL 1 4 1 I63A00 APR 18, 2024 9:22 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 DIESEL 10.00% 2 UNLEADED 10.00% 3 WASTE OIL 10.00% 4 10.00% I61100 APR 18, 2024 9:22 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 29, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 APR 18, 2024 9:22 AM CSLD PROBABLITY OF DETECTION I61400 APR 18, 2024 9:22 AM CSLD CLIMATE FACTOR I61600 APR 18, 2024 9:22 AM TANK PRODUCT LABEL CAL UPDATE 1 DIESEL IMMEDIATE 2 UNLEADED IMMEDIATE 3 WASTE OIL IMMEDIATE 4 IMMEDIATE I61A00 APR 18, 2024 9:22 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 DIESEL DISABLED 2 UNLEADED DISABLED 3 WASTE OIL DISABLED 4 DISABLED I61B00 APR 18, 2024 9:23 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 APR 18, 2024 9:23 AM CSLD REPORT ONLY I62B00 APR 18, 2024 9:23 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 DIESEL ??? 0, 0 2 UNLEADED ??? 0, 0 3 WASTE OIL ??? 0, 0 4 ??? 0, 0 I63300 APR 18, 2024 9:23 AM LEAK TEST REPORT FORMAT: NORMAL I63400 APR 18, 2024 9:23 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 UNLEADED 0 3 WASTE OIL 0 4 0 I63500 APR 18, 2024 9:23 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 1 2 UNLEADED 1 3 WASTE OIL 1 4 1 I63900 APR 18, 2024 9:23 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 DIESEL END FACTOR: NONE 2 UNLEADED END FACTOR: NONE 3 WASTE OIL END FACTOR: NONE 4 END FACTOR: NONE I78000 APR 18, 2024 9:23 AM I77700 APR 18, 2024 9:23 AM I77800 APR 18, 2024 9:23 AM I78C00 APR 18, 2024 9:23 AM I78300 APR 18, 2024 9:23 AM I78F00 APR 18, 2024 9:23 AM I78700 APR 18, 2024 9:23 AM I70200 APR 18, 2024 9:23 AM LIQUID LABEL DEVICE LABEL 1 UNLEADED ANNULAR 2 UNLEADED STP SUMP 3 DIESEL ANNULAR 4 DIESEL STP SUMP 5 DISPENSER 1-2 6 DISPENSER 3-4 7 WASTE OIL 8 I70300 APR 18, 2024 9:23 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED ANNULAR TRI-STATE (SINGLE FLOAT) 2 UNLEADED STP SUMP TRI-STATE (SINGLE FLOAT) 3 DIESEL ANNULAR TRI-STATE (SINGLE FLOAT) 4 DIESEL STP SUMP TRI-STATE (SINGLE FLOAT) 5 DISPENSER 1-2 TRI-STATE (SINGLE FLOAT) 6 DISPENSER 3-4 TRI-STATE (SINGLE FLOAT) 7 WASTE OIL TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I70400 APR 18, 2024 9:23 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED ANNULAR ANNULAR SPACE 2 UNLEADED STP SUMP STP SUMP 3 DIESEL ANNULAR ANNULAR SPACE 4 DIESEL STP SUMP STP SUMP 5 DISPENSER 1-2 DISPENSER PAN 6 DISPENSER 3-4 DISPENSER PAN 7 WASTE OIL OTHER SENSORS 8 OTHER SENSORS I74200 APR 18, 2024 9:23 AM I74300 APR 18, 2024 9:23 AM I74400 APR 18, 2024 9:23 AM I74700 APR 18, 2024 9:23 AM I74800 APR 18, 2024 9:23 AM I74900 APR 18, 2024 9:23 AM I7BC00 APR 18, 2024 9:23 AM I80200 APR 18, 2024 9:23 AM I80300 APR 18, 2024 9:23 AM I80400 APR 18, 2024 9:23 AM I80700 APR 18, 2024 9:23 AM RELAY LABEL DEVICE LABEL 1 UNLEADED SHUTDOWN 2 3 DIESEL SHUTDOWN 4 WASTE OIL I80900 APR 18, 2024 9:23 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED SHUTDOWN NORMALLY CLOSED 2 NORMALLY OPEN 3 DIESEL SHUTDOWN NORMALLY CLOSED 4 WASTE OIL NORMALLY CLOSED I80B00 APR 18, 2024 9:23 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED SHUTDOWN NONE 2 NONE 3 DIESEL SHUTDOWN NONE 4 WASTE OIL NONE I80A00 APR 18, 2024 9:23 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED SHUTDOWN STANDARD 2 STANDARD 3 DIESEL SHUTDOWN STANDARD 4 WASTE OIL STANDARD I80C00 APR 18, 2024 9:23 AM I80800 APR 18, 2024 9:23 AM RELAY SETUP REPORT R 1:UNLEADED SHUTDOWN TYPE: STANDARD NORMALLY CLOSED IN-TANK ALARMS T 2:HIGH WATER ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 6:FUEL ALARM L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 2:SHORT ALARM L 6:SHORT ALARM PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL R 2: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 3:DIESEL SHUTDOWN TYPE: STANDARD NORMALLY CLOSED IN-TANK ALARMS T 1:HIGH WATER ALARM T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM R 4:WASTE OIL TYPE: STANDARD NORMALLY CLOSED IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 APR 18, 2024 9:24 AM I79100 APR 18, 2024 9:24 AM I72300 APR 18, 2024 9:24 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 CCVP VAPOR VALVE 02 PRESSURE SENSOR VAPOR PRESSURE 03 UNKNOWN 04 UNKNOWN 05 UNKNOWN 06 UNKNOWN 07 UNKNOWN 08 ATM ATM P SENSOR 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 APR 18, 2024 9:24 AM IV4F00 APR 18, 2024 9:24 AM IV4000 APR 18, 2024 9:24 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA VAPOR PROCESSOR TYPE VEEDER-ROOT POLISHER IV4700 APR 18, 2024 9:24 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 APR 18, 2024 9:24 AM IV4A00 APR 18, 2024 9:24 AM IV4B00 APR 18, 2024 9:24 AM IV4900 APR 18, 2024 9:24 AM IV1000 APR 18, 2024 9:24 AM ISD VERSION: 01.05 PANAMA BUENA VISTA USD ALARM HISTORY BEFORE: Responses Received: I10200 APR 18, 2024 9:26 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162824 161393 2 INTERSTITIAL BD 203816 202876 3 7SMARTSENSOR BD 512219 509121 4 UNUSED 10242044 10060842 5 UNUSED 10191825 10038675 6 UNUSED 10181529 10036376 7 UNUSED 10179647 10038083 8 UNUSED 10173070 10031346 9 RELAY BOARD 15000 14969 10 UNUSED 10180802 10039947 11 UNUSED 10176705 10039196 12 UNUSED 10172365 10042382 13 UNUSED 10167007 10034348 14 UNUSED 10173672 10029774 15 UNUSED 10159102 10036351 16 UNUSED 10166232 10030411 COMM 1 UNUSED 10165413 10034690 COMM 2 UNUSED 10168845 10033552 COMM 3 UNUSED 10166276 10030889 COMM 4 UNUSED 10158526 10027111 COMM 5 RS485 SERIAL BD 68489 68461 COMM 6 RS232 SERIAL BD 14977 14969 I90200 APR 18, 2024 9:27 AM SOFTWARE REVISION LEVEL VERSION 334.01 SOFTWARE# 346334-100-B CREATED - 17.01.09.16.10 NO SOFTWARE MODULE SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS I11100 APR 18, 2024 9:27 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL LOW PRODUCT ALARM CLEAR 2-13-24 11:03AM T 1 TANK DIESEL LOW PRODUCT ALARM ALARM 2-13-24 10:29AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM CLEAR 12-15-23 1:06PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-23 1:03PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-23 12:37PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-23 12:37PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-23 12:37PM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM ALARM 12-15-23 9:20AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM CLEAR 12-15-23 9:20AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM ALARM 12-15-23 9:20AM T 1 TANK DIESEL LOW PRODUCT ALARM CLEAR 12-11-23 9:14AM T 1 TANK DIESEL LOW PRODUCT ALARM ALARM 12-11-23 7:55AM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 6-02-23 1:56PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 6-02-23 1:56PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 6-02-23 1:55PM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM CLEAR 6-02-23 1:51PM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM ALARM 6-02-23 1:51PM L 5 DISP PAN DISPENSER 1-2 FUEL ALARM CLEAR 6-02-23 1:51PM L 5 DISP PAN DISPENSER 1-2 FUEL ALARM ALARM 6-02-23 1:51PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 6-02-23 1:46PM L 7 OTHER WASTE OIL SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 6 DISP PAN DISPENSER 3-4 SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 3 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 5 DISP PAN DISPENSER 1-2 SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 2 STP SUMP UNLEADED STP SUMP SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 4 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 1 ANNULAR UNLEADED ANNULAR SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 2 STP SUMP UNLEADED STP SUMP SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 7 OTHER WASTE OIL SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 6 DISP PAN DISPENSER 3-4 SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 1 ANNULAR UNLEADED ANNULAR SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 5 DISP PAN DISPENSER 1-2 SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 4 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 3 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 6-02-23 1:25PM L 4 STP SUMP DIESEL STP SUMP FUEL ALARM CLEAR 6-02-23 1:23PM L 4 STP SUMP DIESEL STP SUMP FUEL ALARM ALARM 6-02-23 1:23PM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM CLEAR 6-02-23 1:22PM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM ALARM 6-02-23 1:22PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 6-02-23 1:21PM L 3 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 6-02-23 1:21PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 6-02-23 1:20PM L 3 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 6-02-23 1:20PM L 7 OTHER WASTE OIL FUEL ALARM CLEAR 6-02-23 1:18PM L 7 OTHER WASTE OIL FUEL ALARM ALARM 6-02-23 1:17PM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM CLEAR 5-16-23 8:44AM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM ALARM 5-15-23 2:07PM L 4 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM CLEAR 5-15-23 10:37AM L 3 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 5-15-23 10:37AM L 2 STP SUMP UNLEADED STP SUMP SENSOR OUT ALARM CLEAR 5-15-23 10:37AM L 7 OTHER WASTE OIL SENSOR OUT ALARM CLEAR 5-15-23 10:37AM I11200 APR 18, 2024 9:27 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 3-27-24 2:55PM SYSTEM PAPER OUT CLEAR 3-27-24 2:55PM SYSTEM PRINTER ERROR ALARM 3-27-24 2:53PM SYSTEM PAPER OUT ALARM 3-27-24 2:53PM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 2-13-24 11:03AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 2-13-24 8:21AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 1-26-24 7:50AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 1-26-24 5:59AM SYSTEM PRINTER ERROR CLEAR 1-23-24 6:22AM SYSTEM PRINTER ERROR ALARM 1-23-24 6:22AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 12-11-23 9:14AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 12-09-23 7:59AM SYSTEM PRINTER ERROR CLEAR 12-04-23 1:41PM SYSTEM PAPER OUT CLEAR 12-04-23 1:41PM SYSTEM PAPER OUT ALARM 12-04-23 1:41PM SYSTEM PRINTER ERROR ALARM 12-04-23 1:41PM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 10-30-23 1:12PM T 1 TANK DIESEL DELIVERY NEEDED ALARM 10-30-23 9:00AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 9-27-23 8:05AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 9-27-23 7:20AM SYSTEM PRINTER ERROR CLEAR 7-18-23 7:14AM SYSTEM PAPER OUT CLEAR 7-18-23 7:14AM SYSTEM PAPER OUT ALARM 7-18-23 7:11AM SYSTEM PRINTER ERROR ALARM 7-18-23 7:11AM SYSTEM PRINTER ERROR CLEAR 7-14-23 9:00AM SYSTEM PRINTER ERROR ALARM 7-14-23 9:00AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 5-12-23 7:59AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 5-12-23 7:35AM SYSTEM PRINTER ERROR CLEAR 4-25-23 1:44PM SYSTEM PAPER OUT CLEAR 4-25-23 1:44PM SYSTEM PRINTER ERROR ALARM 4-25-23 1:40PM SYSTEM PAPER OUT ALARM 4-25-23 1:40PM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 3-16-23 1:22PM T 1 TANK DIESEL DELIVERY NEEDED ALARM 3-16-23 8:58AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 12-22-22 8:30AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 12-21-22 3:08PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:16PM SYSTEM PAPER OUT CLEAR 12-09-22 1:16PM SYSTEM PRINTER ERROR ALARM 12-09-22 1:15PM SYSTEM PAPER OUT ALARM 12-09-22 1:15PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:14PM SYSTEM PRINTER ERROR ALARM 12-09-22 1:14PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:14PM SYSTEM PRINTER ERROR ALARM 12-09-22 1:13PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:11PM SYSTEM PAPER OUT CLEAR 12-09-22 1:11PM SYSTEM PRINTER ERROR ALARM 12-07-22 12:53PM SYSTEM PAPER OUT ALARM 12-07-22 12:53PM SYSTEM PRINTER ERROR CLEAR 12-07-22 12:51PM SYSTEM PRINTER ERROR ALARM 12-07-22 12:51PM I20600 APR 18, 2024 9:28 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA TANK ALARM HISTORY TANK 1 DIESEL OVERFILL ALARM MAY 25, 2021 1:17 PM APR 7, 2021 9:42 AM APR 8, 2020 10:28 AM LOW PRODUCT ALARM FEB 13, 2024 10:29 AM DEC 11, 2023 7:55 AM MAR 16, 2023 11:57 AM HIGH PRODUCT ALARM APR 10, 2019 2:33 PM JUN 9, 2017 9:57 AM JUN 9, 2017 9:39 AM INVALID FUEL LEVEL APR 7, 2021 9:41 AM APR 8, 2020 10:28 AM FEB 7, 2020 12:48 PM PROBE OUT APR 7, 2021 9:44 AM APR 7, 2021 9:40 AM APR 8, 2020 10:30 AM HIGH WATER WARNING JUN 9, 2017 9:39 AM DELIVERY NEEDED FEB 13, 2024 8:21 AM JAN 26, 2024 5:59 AM DEC 9, 2023 7:59 AM MAX PRODUCT ALARM JUN 9, 2017 9:57 AM JUN 9, 2017 9:39 AM TANK 2 UNLEADED HIGH WATER ALARM JUN 9, 2017 9:41 AM OVERFILL ALARM APR 7, 2021 9:30 AM APR 8, 2020 10:39 AM APR 10, 2019 2:26 PM LOW PRODUCT ALARM FEB 7, 2020 12:53 PM HIGH PRODUCT ALARM APR 10, 2019 2:31 PM APR 10, 2019 2:26 PM JUN 9, 2017 9:46 AM INVALID FUEL LEVEL APR 7, 2021 9:29 AM PROBE OUT APR 7, 2021 9:32 AM APR 7, 2021 9:28 AM APR 8, 2020 10:40 AM HIGH WATER WARNING JUN 9, 2017 9:41 AM DELIVERY NEEDED JUL 2, 2020 6:16 AM FEB 7, 2020 12:53 PM JUL 11, 2018 6:28 AM MAX PRODUCT ALARM JUN 9, 2017 9:46 AM LOW TEMP WARNING APR 8, 2020 10:42 AM JUL 5, 2019 8:26 PM FEB 8, 2017 12:45 PM TANK 3 WASTE OIL OVERFILL ALARM APR 10, 2019 3:08 PM APR 10, 2019 2:56 PM HIGH PRODUCT ALARM JAN 31, 2022 2:21 PM JUL 5, 2019 8:22 PM APR 10, 2019 3:05 PM PROBE OUT APR 10, 2019 3:09 PM APR 10, 2019 2:48 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 18, 2024 9:28 AM I30200 APR 18, 2024 9:28 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED ANNULAR DEC 15, 2023 12:37 PM FUEL ALARM DEC 15, 2023 12:37 PM FUEL ALARM JUN 2, 2023 1:56 PM FUEL ALARM 2 UNLEADED STP SUMP DEC 15, 2023 9:20 AM FUEL ALARM DEC 15, 2023 9:20 AM FUEL ALARM JUN 2, 2023 1:25 PM SENSOR OUT ALARM 3 DIESEL ANNULAR JUN 2, 2023 1:25 PM SENSOR OUT ALARM JUN 2, 2023 1:20 PM FUEL ALARM MAY 15, 2023 10:35 AM SENSOR OUT ALARM 4 DIESEL STP SUMP JUN 2, 2023 1:25 PM SENSOR OUT ALARM JUN 2, 2023 1:23 PM FUEL ALARM MAY 15, 2023 10:35 AM SENSOR OUT ALARM 5 DISPENSER 1-2 JUN 2, 2023 1:51 PM FUEL ALARM JUN 2, 2023 1:25 PM SENSOR OUT ALARM MAY 15, 2023 10:35 AM SENSOR OUT ALARM 6 DISPENSER 3-4 JUN 2, 2023 1:51 PM FUEL ALARM JUN 2, 2023 1:25 PM SENSOR OUT ALARM MAY 15, 2023 2:07 PM FUEL ALARM 7 WASTE OIL JUN 2, 2023 1:25 PM SENSOR OUT ALARM JUN 2, 2023 1:17 PM FUEL ALARM MAY 15, 2023 10:35 AM SENSOR OUT ALARM I31600 APR 18, 2024 9:29 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 CCVP JAN 30, 2017 11:32 AM COMMUNICATION ALARM JAN 19, 2017 12:52 PM COMMUNICATION ALARM JAN 9, 2017 8:22 AM COMMUNICATION ALARM 2 PRESSURE SENSOR JAN 19, 2017 12:50 PM COMMUNICATION ALARM JAN 9, 2017 8:18 AM COMMUNICATION ALARM 8 ATM I40200 APR 18, 2024 9:29 AM I40300 APR 18, 2024 9:29 AM I34200 APR 18, 2024 9:29 AM I34700 APR 18, 2024 9:29 AM IV0100 APR 18, 2024 9:29 AM AFTER: Responses Received: I10200 APR 18, 2024 11:16 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162824 161344 2 INTERSTITIAL BD 203816 202906 3 7SMARTSENSOR BD 512219 509344 4 UNUSED 10242044 10033701 5 UNUSED 10191825 10015038 6 UNUSED 10181529 10013898 7 UNUSED 10179647 10025315 8 UNUSED 10173070 10013898 9 RELAY BOARD 15000 14984 10 UNUSED 10180802 10022577 11 UNUSED 10176705 10021164 12 UNUSED 10172365 10021347 13 UNUSED 10167007 10018202 14 UNUSED 10173672 10018316 15 UNUSED 10159102 10017290 16 UNUSED 10166232 10016402 COMM 1 UNUSED 10165413 10012642 COMM 2 UNUSED 10168845 10013895 COMM 3 UNUSED 10166276 10017313 COMM 4 UNUSED 10158526 10008403 COMM 5 RS485 SERIAL BD 68489 68430 COMM 6 RS232 SERIAL BD 14977 14984 I90200 APR 18, 2024 11:16 AM SOFTWARE REVISION LEVEL VERSION 334.01 SOFTWARE# 346334-100-B CREATED - 17.01.09.16.10 NO SOFTWARE MODULE SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS I11100 APR 18, 2024 11:16 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 7 OTHER WASTE OIL SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 6 DISP PAN DISPENSER 3-4 SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 5 DISP PAN DISPENSER 1-2 SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 4 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 3 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 2 STP SUMP UNLEADED STP SUMP SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 1 ANNULAR UNLEADED ANNULAR SENSOR OUT ALARM CLEAR 4-18-24 10:16AM L 4 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 7 OTHER WASTE OIL SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 3 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 6 DISP PAN DISPENSER 3-4 SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 2 STP SUMP UNLEADED STP SUMP SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 5 DISP PAN DISPENSER 1-2 SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 1 ANNULAR UNLEADED ANNULAR SENSOR OUT ALARM ALARM 4-18-24 10:16AM L 7 OTHER WASTE OIL FUEL ALARM CLEAR 4-18-24 10:12AM L 7 OTHER WASTE OIL FUEL ALARM ALARM 4-18-24 10:11AM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM CLEAR 4-18-24 10:07AM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM ALARM 4-18-24 10:07AM L 5 DISP PAN DISPENSER 1-2 FUEL ALARM CLEAR 4-18-24 10:06AM L 5 DISP PAN DISPENSER 1-2 FUEL ALARM ALARM 4-18-24 10:06AM L 3 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 4-18-24 10:05AM L 3 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 4-18-24 10:05AM L 4 STP SUMP DIESEL STP SUMP FUEL ALARM CLEAR 4-18-24 10:04AM L 4 STP SUMP DIESEL STP SUMP FUEL ALARM ALARM 4-18-24 10:04AM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 4-18-24 10:02AM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 4-18-24 10:02AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM CLEAR 4-18-24 10:01AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM ALARM 4-18-24 10:01AM T 1 TANK DIESEL LOW PRODUCT ALARM CLEAR 2-13-24 11:03AM T 1 TANK DIESEL LOW PRODUCT ALARM ALARM 2-13-24 10:29AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM CLEAR 12-15-23 1:06PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-23 1:03PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-23 12:37PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-23 12:37PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-23 12:37PM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM ALARM 12-15-23 9:20AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM CLEAR 12-15-23 9:20AM L 2 STP SUMP UNLEADED STP SUMP FUEL ALARM ALARM 12-15-23 9:20AM T 1 TANK DIESEL LOW PRODUCT ALARM CLEAR 12-11-23 9:14AM T 1 TANK DIESEL LOW PRODUCT ALARM ALARM 12-11-23 7:55AM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 6-02-23 1:56PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 6-02-23 1:56PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 6-02-23 1:55PM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM CLEAR 6-02-23 1:51PM L 6 DISP PAN DISPENSER 3-4 FUEL ALARM ALARM 6-02-23 1:51PM L 5 DISP PAN DISPENSER 1-2 FUEL ALARM CLEAR 6-02-23 1:51PM L 5 DISP PAN DISPENSER 1-2 FUEL ALARM ALARM 6-02-23 1:51PM L 1 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 6-02-23 1:46PM L 7 OTHER WASTE OIL SENSOR OUT ALARM CLEAR 6-02-23 1:27PM L 6 DISP PAN DISPENSER 3-4 SENSOR OUT ALARM CLEAR 6-02-23 1:27PM I11200 APR 18, 2024 11:17 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 3-27-24 2:55PM SYSTEM PAPER OUT CLEAR 3-27-24 2:55PM SYSTEM PRINTER ERROR ALARM 3-27-24 2:53PM SYSTEM PAPER OUT ALARM 3-27-24 2:53PM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 2-13-24 11:03AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 2-13-24 8:21AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 1-26-24 7:50AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 1-26-24 5:59AM SYSTEM PRINTER ERROR CLEAR 1-23-24 6:22AM SYSTEM PRINTER ERROR ALARM 1-23-24 6:22AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 12-11-23 9:14AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 12-09-23 7:59AM SYSTEM PRINTER ERROR CLEAR 12-04-23 1:41PM SYSTEM PAPER OUT CLEAR 12-04-23 1:41PM SYSTEM PAPER OUT ALARM 12-04-23 1:41PM SYSTEM PRINTER ERROR ALARM 12-04-23 1:41PM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 10-30-23 1:12PM T 1 TANK DIESEL DELIVERY NEEDED ALARM 10-30-23 9:00AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 9-27-23 8:05AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 9-27-23 7:20AM SYSTEM PRINTER ERROR CLEAR 7-18-23 7:14AM SYSTEM PAPER OUT CLEAR 7-18-23 7:14AM SYSTEM PAPER OUT ALARM 7-18-23 7:11AM SYSTEM PRINTER ERROR ALARM 7-18-23 7:11AM SYSTEM PRINTER ERROR CLEAR 7-14-23 9:00AM SYSTEM PRINTER ERROR ALARM 7-14-23 9:00AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 5-12-23 7:59AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 5-12-23 7:35AM SYSTEM PRINTER ERROR CLEAR 4-25-23 1:44PM SYSTEM PAPER OUT CLEAR 4-25-23 1:44PM SYSTEM PRINTER ERROR ALARM 4-25-23 1:40PM SYSTEM PAPER OUT ALARM 4-25-23 1:40PM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 3-16-23 1:22PM T 1 TANK DIESEL DELIVERY NEEDED ALARM 3-16-23 8:58AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 12-22-22 8:30AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 12-21-22 3:08PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:16PM SYSTEM PAPER OUT CLEAR 12-09-22 1:16PM SYSTEM PRINTER ERROR ALARM 12-09-22 1:15PM SYSTEM PAPER OUT ALARM 12-09-22 1:15PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:14PM SYSTEM PRINTER ERROR ALARM 12-09-22 1:14PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:14PM SYSTEM PRINTER ERROR ALARM 12-09-22 1:13PM SYSTEM PRINTER ERROR CLEAR 12-09-22 1:11PM SYSTEM PAPER OUT CLEAR 12-09-22 1:11PM SYSTEM PRINTER ERROR ALARM 12-07-22 12:53PM SYSTEM PAPER OUT ALARM 12-07-22 12:53PM SYSTEM PRINTER ERROR CLEAR 12-07-22 12:51PM SYSTEM PRINTER ERROR ALARM 12-07-22 12:51PM I20600 APR 18, 2024 11:17 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA TANK ALARM HISTORY TANK 1 DIESEL OVERFILL ALARM MAY 25, 2021 1:17 PM APR 7, 2021 9:42 AM APR 8, 2020 10:28 AM LOW PRODUCT ALARM FEB 13, 2024 10:29 AM DEC 11, 2023 7:55 AM MAR 16, 2023 11:57 AM HIGH PRODUCT ALARM APR 10, 2019 2:33 PM JUN 9, 2017 9:57 AM JUN 9, 2017 9:39 AM INVALID FUEL LEVEL APR 7, 2021 9:41 AM APR 8, 2020 10:28 AM FEB 7, 2020 12:48 PM PROBE OUT APR 7, 2021 9:44 AM APR 7, 2021 9:40 AM APR 8, 2020 10:30 AM HIGH WATER WARNING JUN 9, 2017 9:39 AM DELIVERY NEEDED FEB 13, 2024 8:21 AM JAN 26, 2024 5:59 AM DEC 9, 2023 7:59 AM MAX PRODUCT ALARM JUN 9, 2017 9:57 AM JUN 9, 2017 9:39 AM TANK 2 UNLEADED HIGH WATER ALARM JUN 9, 2017 9:41 AM OVERFILL ALARM APR 7, 2021 9:30 AM APR 8, 2020 10:39 AM APR 10, 2019 2:26 PM LOW PRODUCT ALARM FEB 7, 2020 12:53 PM HIGH PRODUCT ALARM APR 10, 2019 2:31 PM APR 10, 2019 2:26 PM JUN 9, 2017 9:46 AM INVALID FUEL LEVEL APR 7, 2021 9:29 AM PROBE OUT APR 7, 2021 9:32 AM APR 7, 2021 9:28 AM APR 8, 2020 10:40 AM HIGH WATER WARNING JUN 9, 2017 9:41 AM DELIVERY NEEDED JUL 2, 2020 6:16 AM FEB 7, 2020 12:53 PM JUL 11, 2018 6:28 AM MAX PRODUCT ALARM JUN 9, 2017 9:46 AM LOW TEMP WARNING APR 8, 2020 10:42 AM JUL 5, 2019 8:26 PM FEB 8, 2017 12:45 PM TANK 3 WASTE OIL OVERFILL ALARM APR 10, 2019 3:08 PM APR 10, 2019 2:56 PM HIGH PRODUCT ALARM JAN 31, 2022 2:21 PM JUL 5, 2019 8:22 PM APR 10, 2019 3:05 PM PROBE OUT APR 10, 2019 3:09 PM APR 10, 2019 2:48 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 18, 2024 11:18 AM I30200 APR 18, 2024 11:18 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED ANNULAR APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:02 AM FUEL ALARM DEC 15, 2023 12:37 PM FUEL ALARM 2 UNLEADED STP SUMP APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:01 AM FUEL ALARM DEC 15, 2023 9:20 AM FUEL ALARM 3 DIESEL ANNULAR APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:05 AM FUEL ALARM JUN 2, 2023 1:25 PM SENSOR OUT ALARM 4 DIESEL STP SUMP APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:04 AM FUEL ALARM JUN 2, 2023 1:25 PM SENSOR OUT ALARM 5 DISPENSER 1-2 APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:06 AM FUEL ALARM JUN 2, 2023 1:51 PM FUEL ALARM 6 DISPENSER 3-4 APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:07 AM FUEL ALARM JUN 2, 2023 1:51 PM FUEL ALARM 7 WASTE OIL APR 18, 2024 10:16 AM SENSOR OUT ALARM APR 18, 2024 10:11 AM FUEL ALARM JUN 2, 2023 1:25 PM SENSOR OUT ALARM I31600 APR 18, 2024 11:18 AM PANAMA BUENA VISTA 4200 ASHE RD BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 CCVP JAN 30, 2017 11:32 AM COMMUNICATION ALARM JAN 19, 2017 12:52 PM COMMUNICATION ALARM JAN 9, 2017 8:22 AM COMMUNICATION ALARM 2 PRESSURE SENSOR JAN 19, 2017 12:50 PM COMMUNICATION ALARM JAN 9, 2017 8:18 AM COMMUNICATION ALARM 8 ATM I40200 APR 18, 2024 11:18 AM I40300 APR 18, 2024 11:18 AM I34200 APR 18, 2024 11:18 AM I34700 APR 18, 2024 11:18 AM IV0100 APR 18, 2024 11:18 AM