HomeMy WebLinkAbout3505 Buck Owens Blvd_Linda Gas & Equipment INC_10.19.23_SQGM 5 ✓ G�e2 S ✓
HAZARDOUS WASTE ,��. BAKERSFIELD FIRE DEPARTMENT
UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services
SMALL QUANTITY HAZARDOUS
2101 H Street
- WASTE GENERATOR INSPECTION �� Bakersfield, CA 93301Phone: 661-326-3979 • Fax: 661-852-2171
Facility Name: L / & r Date: 10
Site Address: V1510r` Time In: Time Out:
Owner/Operator: Phone: EPA ID # jo:�'A L0001ZEt % S
Type of Inspection / ,C* VC
— Routine — Re-inspection/Follow-up rl Combined Routine Inspection F1 Joint Inspection — Complaint — Focused n Other
_ CONSENT TO INSPECT GRANTED BY (Name / Title):
Inspection may involve obtaining photographs, review and copying o records, and determination of compliance with hazardous waste handling requirements.
C = C'mmnlnint- V = ('.lac-, T TT nr Minnr Vinlntinn
C
V I
HAZARDOUS WASTE REQUIREMENT
N/A
CERS
Violation #
COMMENTS
Recordkee in /documentation
Generator has an EPA ID number HSC 25143.13
3010002
Hazardous waste determination made for all wastes
I I Analysis Pf6enerator Knowledge [CCR 66262.40]
3030005
Contingency lan information posted near phone CCR 66262.34(d)(2)
3010022
Facility personnel demonstrate training/awareness [CCR 66262.34(d)(2)]
3020001
Manifests/Consolidated Manifest receipts complete [CCR 66262.23(a)]
3010008
Blue copy(s) of manifest mailed to DTSC [CCR 66262.23(a)(4)]
3010011
Bills of Lading/receipts available CCR 66262.40(a)]
3010010
LDRs available and complete CCR 66268.7(a)
3030006
Onsite recycling reported using UPCF HSC 25143.10]
3030001
Container/tank management
Containers are in good condition [CCR 66262.34(d)(2)]
3030013
Containers are closed except when adding/removing [CCR66262.34(d)(2)]
3030017
OT
Satellite containers at or near point of generation CCR 66262.34(e)(1)(A)
Empty containers are empty [CCR 66262.34(f)]
3030007
Containers inspected weekly CCR 66262.34(d)(2)
3030019
Tanks inspected daily CCR 66262.34(d)(2), 40CFR 265.201
3030027
One container per waste stream at satellite area CCR 66262.34(d)(2)
3030022
are..-
Exclude recyclable materials stored in accordance with local
ordinance/hazardous materials codes [HSC 25143.10]
3010016
,-
Accumulation Time Limits
Waste is accumulated not more than 90e 8OZ270 CCR 66262.34(d)
3030010Empty
containers managed within one year CCR 66262.34(d)
3030010
Universal waste accumulated less than one year CCR 66273.15(a)
3030011
Used oil filters offsite within 180 (1 year <1 ton) CCR 66266.130(c)(4)]
3030004
Pb-acid batteries offsite within 180 (1 yr. < 1 ton) CCR66266.8I(a)(3)
3030002
Labeling/Marking
Vr
Containers are properly labeled [66262.34(f)]
3030007
Excluded recyclable materials marked properly [HSC 25143.9(a)]
3050005
Universal waste container properly labeled (CCR 66273.34
3030008
VOO
Used oil filters marked "drained used oil filters" CCR 66266.130
3030004
Date written on spent lead -acid batteries CCR 66266.8 1 (a)(6)(B)j3030003
"Used Oil" marked on all used oil tanks/containers [CCR 66279.21(b)]
3030007
y
Tank marked with "haz waste" , contents, start date [66262.34(f)]
I 3030007
• - �-
Treatment, Transport and Disposal/Other
Have ermit/authorization to do treatment [HSC 25136.2]
3040003
Waste sent with authorized transport (gen. eligible) CCR 66263.41
3050001
Waste disposed of to authorizedpoint/party [HSC 25189.5(a)]
3050002
Failed to properly handle appliance wastes HSC 25212(a)
I
-
Fire Protection 66262.34(d)(2) 9-3030032
Print and sign in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report.
�2 ..
INSPECTOR
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301
Signature (that all violations have been corrected as noted)
Date
FD2171 (Rev 4/2018)