HomeMy WebLinkAboutORD NO 3911OnniNA CE NO. II 9 I I AN ORDINANCE REPEALING CHAPTER 15.28 OF THE BAKERSFIELD MUNICIPAL CODE RELATING TO THE UNIFORM PLUMBING CODE AND ADOPTING AND ADDING A NEW CHAPTER 15.28 THERETO. BE IT ORDAINED by the Council of the City of Bakersfield as follows: SECTION 1. Chapter 15.28 of the Bakersfield Municipal Code relating to the Uniform Plumbing Code is hereby repealed. SECTION 2. follows: A new Chapter 15.28 of the Bakersfield Municipal Code is added to read as Chapter 15.28 UNIFORM PLUM.BING CODE Sections: 15.28.010 15.28.020 15.28.025 15.28.030 15.28.040 15.28.050 15.28.060 15.28.070 15.28.080 Adoption. Modifications. Section 404.0 amended - Overflows. Table 4-1: Amended -- Minimum plumbing facilities. Section 510.2 Added -- Waterheater Floor Support. Section 609.3.1 Amended -- Installation, inspection and testing. 609.4.1 Testing. Section 713.4 Amended -- Sewer required. Section 1212.0 Added -- Appliance connectors. 15.28.010 Adoption. Except as otherwise provided in this chapter, that certain plumbing code known and designated as the Uniform Plumbing Code (with appendices A through I), as modified by the 1998 Edition of the Califomia Building Standards Code, sponsored and copyrighted by the International Association of Plumbing and Mechanical Officials, a copy of which has been filed with the Building Department of the City for use and examination by the public, is adopted by reference and enacted as the plumbing code of the City for the purpose stated therein. 15.28.020 Modifications. The sections of the Uniform Plumbing Code, 1997 Edition, mentioned in Sections 15.28.025 through 15.28.100 of this chapter, as adopted by reference, are modified and amended as provided in Sections 15.28.025 through 15.28.100 of this chapter. 15.28.025 15.28.030 Section 404.0 amended - Overflows. Section 404.0 is amended by adding a paragraph as follows: Overflows are required on all bathtub installations. Table 4-1: Amended - Minimum plumbing facilities. --all assembly type buildings as defined in the Uniform Building Code Definitions, shall have flush valves for water closets. Table 4-1 is amended by adding footnote 15 which states: Flush valve requirements under Chapter 2, Exception: Restricted rest rooms for employees only. 15.28.040 Section 510.2 Added -- Water Heater Floor Support. Add a new paragraph to read: All gas fired water heaters installed on combustible construction shall have floor under water heater made of non-combustible material approved by the Administrative Authority. 15.28.050 Section 609.3.1 Amended -- Installation, inspection and Section 609.3.1 is amended to read as follows: 609.3.1 No water piping shall be installed within a concrete slab or in the ground under a concrete slab of a building. 2 Exceptions: If required by structural conditions, water piping may be installed in chases, sleeves or ducts with the prior approval of the administrative authority. All piping shall be chased, sleeved or ducted the entire length within a concrete slab or in the ground under a concrete slab of a building. Chase, sleeves or ducts shall extend six (6) inches above grade at both ends. 2. Water piping for swimming pools and/or spas. 15.28.060 Section 609.4.1 Testing Recirculating water for swimming pools shall be constructed and installed under the same standards and requirements as potable water piping. 15.28.070 Section 713.4 Amended -- Sewer required. Sections 713.4 is amended to read as follows: 713.4 The public sewer may be considered as not being available when such public sewer or any building or any exterior drainage facility connected thereto, is located more than one thousand (1,000) feet from the nearest property line of any proposed building or exterior drainage facility on any lot or premises which abuts and is served by such public sewer· Exceptions: 1. The above requirement may be reduced to two hundred (200) feet if the proposed development is for residential living units and is four units or less. 2. The requirements may be waived or modified by the Building Official when strict compliance may cause extreme hardship. 15.28.080 Section 1212.0 added -- Appliance connectors. Add a new paragraph (9) to read: All appliance connectors installed in the exterior application, except mobile home gas flex, shall be of rigid piping or stainless steel connectors that have been approved by the appropriate testing agency. SECTION 3. This Ordinance shall be posted h~ accordance with the Bakersfield Municipal Code and shall become effective thir~ (30) days from and after the date of its passage. .......... o0o .......... 4 I HEREBY CERTIFY that the foregoing Ordinance was passed and adopted by the Council of the City of Bakersfield at a regular meeting thereof held on dUN 3 0 1999 , by the following vote: AYES: NOES: ABSTAIN: ABSENT: COUNCILMEMBER CARSON, SULLIVAN. SALVAGGIO COUNCILMEMBER NO5 ~d ~-_ COUNCILMEMBER COUNCILMEMBER DEMOND, MAGGARD, COUCH, ROWLES, of the APPROVED JUN 3 0 1999 MAYOR of the City of Bakersfield APPROVED as to form: CITY ATTORNEY BY: C CARL HERNANDEZ III Assistant City Attorney upc 5 AFFIDAVIT OF POSTING DOCUMENTS STATE OF CALIFORNIA) ) County of Kern ) PAMELA A. MCCARTHY, being duly sworn, deposes and says: That she is the duly appointed, acting and qualified City Clerk of the City of Bakersfield; and that on the 1st day of July , 1999 she posted on the Bulletin Board at City Hall, a full, true and correct copy of the following: Ordinance No. 3911 , passed by the Bakersfield City Council at a meeting held on the 30th day of June 1999 , and entitled: AN ORDINANCE REPEALING CHAPTER 15.28 OF THE BAKERSFIELD MUNICIPAL CODE RELATING TO THE UNIFORM PLUMBING CODE AND ADOPTING AND ADDING A NEW CHAPTER 15.28 THERETO. /s/PAMELA A. MCCARTHY City Clerk of the City of Bakersfield By: --, DEPUTY City Clerk S:\DOCUMEN'IM~OPOSTING July 1, 1999