HomeMy WebLinkAbout2024 FMC RESULTSCERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10028320 5/30/2024 5257313 12/14/2024 Veeder-Root 06/22/2025 OPW Franklin Vaporless 10/08/2024 10/06/2024 12/29/2024 5/30/2024 6 Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;Monitoring System Set-up Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? Secondary containment systems are free of damage, debris, or liquid? Are the audible and visual alarms operational? All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? The monitoring system set-up was reviewed, and proper settings confirmed? Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)Sump UDC If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 TLS-350R 336.02 Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Page 4 of 6 7. LINE LEAK DETECTOR TESTING Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) 3 GPH 0.1 GPH 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? For electronic LLDs, does the turbine automatically shut off when a release is detected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Were all items on the equipment manufacturer’s maintenance checklist completed? Were all LLDs confirmed operational within regulatory requirements? LLD ID LLD Model Lines Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Page 5 of 6 8. IN-TANK GAUGING TESTING Check this box if tank gauging is used only for inventory control. Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? Was accuracy of system’s product level readings tested? Was accuracy of system’s water level readings tested? Were all probes reinstalled properly? Were all items on the equipment manufacturer’s maintenance checklist completed? Probe ID Probe Model Tanks Monitored Pass Fail 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION Installation Repair 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages Veeder-Root 06/22/2025 5257313 12/14/2024 05/30/202410028320 05/30/2024 6 Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? Yes No Yes No Yes No Yes No OPE Model What is the OPE response when activated? (Check all that apply.) Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? Yes* No Yes* No Yes* No Yes* No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? Yes No Yes* No Yes* No Yes* No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results Pass Fail Pass Fail Pass Fail Pass Fail 1 8. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. * Mark here if: Flow restrictors interfere with overfill prevention and equipment repairs required. 99.00"99.00"99.00"40.00" CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION Installation Repair 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10028320 5/30/2024 Costco wholesale #643 4900 Panama Lane Bakersfield 5/30/2024 2 93313 12/14/2024 Veeeder-Root OPW Franklin 06/22/2025 10/08/2024 10/06/2024 Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? Yes No Yes No Yes No Yes No OPE Model What is the OPE response when activated? (Check all that apply.) Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? Yes* No Yes* No Yes* No Yes* No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? Yes No Yes* No Yes* No Yes* No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results Pass Fail Pass Fail Pass Fail Pass Fail 1 8. COMMENTS * Mark here if: Flow restrictors interfere with overfill prevention and equipment repairs required. T-1 Unl.87A T-2 Unl.87B T-3 Premium 104.25 104.25 95%95%95% 708592902 708592902 708592902 104.25 Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaire. T-4 OPWFSTOP 42.00 95% CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 05/30/2024 5257313 12/14/2024 OPW Franklin 10/08/2024 5/30/2024 2 10/06/2024 Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by Manufacturer Industry Standard Professional Engineer Test Type Pressure Vacuum Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection Nonmetallic Other Nonmetallic Other Nonmetallic Other Nonmetallic Other Is the spill container minimum capacity five gallons excluding riser volume? Yes No* Yes No* Yes No* Yes No* Method to keep spill container empty Drain Pump Other Drain Pump Other Drain Pump Other Drain Pump Other Spill Container Test Results Pass Fail Pass Fail Pass Fail Pass Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection Nonmetallic Other Nonmetallic Other Nonmetallic Other Nonmetallic Other Is the spill container minimum capacity five gallons excluding riser volume? Yes No* Yes No* Yes No* Yes No* Method to keep spill container empty Drain Pump Other Drain Pump Other Drain Pump Other Drain Pump Other Spill Container Test Results Pass Fail Pass Fail Pass Fail Pass Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. Cleaned debri from 87B Fill Bucket. Replaced O-Ring and re-tested. Spill Bucket Passed. file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] +=============================================================+| Monitoring System Report using Report Utility by FASTECH || Version: Version 6.0.0.100 |+=============================================================+ Connected on PC Port: COM3 Settings: 9600 Odd 7, 1 Connect Time/Date from PC Clock: Thursday, May 30, 2024 - 8:21:44 AM Connect Date from Monitoring System: 240530Connect Time from Monitoring System Clock: 08:16 Site Label: 279395 COSTCO #6434900 Panama LaneBakersfield, CA ============================Request: 1 - 200 - Site LocationRequest Source: Monitor System Configuration Requests - Line: 1 _________________________ 200279395 COSTCO #643 4900 Panama Lane Bakersfield, CA MAY 30, 2024 8:16 TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 Unleaded 87A 22277 78.09 0.0 75.4 8215 2 Unleaded 87B 21414 78.44 0.0 74.8 8085 3 Premium 24600 86.91 0.0 73.9 5569 4 Gas Additive 876 26.59 88.7 638 ============================Request: 2 - I90500 - System Revision LevelRequest Source: Monitor System Configuration Requests - Line: 2 _________________________ I90500MAY 30, 2024 8:16SOFTWARE REVISION LEVELVERSION 336.02SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-164-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 3 - I50500 - System Type & languageRequest Source: Monitor System Configuration Requests - Line: 3 _________________________ I50500MAY 30, 2024 8:16 SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S.SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMON DD YYYY HH:MM:SS ============================Request: 4 - I50201 - Shift Start Time 1Request Source: Monitor System Configuration Requests - Line: 4 _________________________ I50201MAY 30, 2024 8:16 SHIFT TIME 1 : DISABLED ============================Request: 5 - I50202 - Shift Start Time 2Request Source: Monitor System Configuration Requests - Line: 5 _________________________ I50202MAY 30, 2024 8:16 SHIFT TIME 2 : DISABLED ============================Request: 6 - I50203 - Shift Start Time 3Request Source: Monitor System Configuration Requests - Line: 6 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] _________________________ I50203MAY 30, 2024 8:16 SHIFT TIME 3 : DISABLED ============================Request: 7 - I50204 - Shift Start Time 4Request Source: Monitor System Configuration Requests - Line: 7 _________________________ I50204MAY 30, 2024 8:16 SHIFT TIME 4 : DISABLED ============================Request: 8 - I54600 - Tank Periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 8 _________________________ I54600MAY 30, 2024 8:16 TANK PER TST NEEDED WRN: DISABLED ============================Request: 9 - I54900 - Tank Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 9 _________________________ I54900MAY 30, 2024 8:16 TANK ANN TST NEEDED WRN: DISABLED ============================Request: 10 - I55300 - Line Re-Enable MethodRequest Source: Monitor System Configuration Requests - Line: 10 _________________________ I55300MAY 30, 2024 8:16 LINE RE-ENABLE METHODPASS LINE TEST file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ============================Request: 11 - I55600 - Line periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 11 _________________________ I55600MAY 30, 2024 8:16 LINE PER TST NEEDED WRN: DISABLED ============================Request: 12 - I55900 - Line Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 12 _________________________ I55900MAY 30, 2024 8:16 LINE ANN TST NEEDED WRN: DISABLED ============================Request: 13 - I50D00 - Print Temperature CompensationRequest Source: Monitor System Configuration Requests - Line: 13 _________________________ I50D00MAY 30, 2024 8:16 PRINT TC VOLUMESENABLED ============================Request: 14 - I50E00 - Temperature Compensation ValueRequest Source: Monitor System Configuration Requests - Line: 14 _________________________ I50E00MAY 30, 2024 8:16 TEMP COMPENSATIONVALUE (DEG F ): 60.0 ============================Request: 15 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 15 _________________________ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] I60B00MAY 30, 2024 8:16 STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 16 - I51400 - H-Protocol Height-Volume FormatRequest Source: Monitor System Configuration Requests - Line: 16 _________________________ I51400MAY 30, 2024 8:16 H-PROTOCOL DATA FORMATHEIGHT ============================Request: 17 - I51A01 - Auto Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 17 _________________________ I51A01MAY 30, 2024 8:16 DAYLIGHT SAVING TIMEENABLED ON ============================Request: 18 - I51B00 - Start-End Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 18 _________________________ I51B00MAY 30, 2024 8:16 DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM ============================Request: 19 - I51600 - Re-Direct Local PrintoutRequest Source: Monitor System Configuration Requests - Line: 19 _________________________ I51600MAY 30, 2024 8:16 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] RE-DIRECT LOCAL PRINTOUTDISABLED ============================Request: 20 - I50400 - RS-232 Security CodeRequest Source: Monitor System Configuration Requests - Line: 20 _________________________ I50400MAY 30, 2024 8:16 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED ============================Request: 21 - I21900 - Tank Chart SecurityRequest Source: Monitor System Configuration Requests - Line: 21 _________________________ I21900MAY 30, 2024 8:16 TANK CHART SECURITYDISABLED ============================Request: 22 - I5BD00 - Custom AlarmsRequest Source: Monitor System Configuration Requests - Line: 22 _________________________ I5BD00MAY 30, 2024 8:16 CUSTOM ALARM LABELS DISABLED ============================Request: 23 - I56000 - Mass Density Enable-Disable file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] Request Source: Monitor System Configuration Requests - Line: 23 _________________________ I56000MAY 30, 2024 8:16 MASS/DENSITY DISABLED ============================Request: 24 - I88101 - Comm Port 1 SettingsRequest Source: Monitor System Configuration Requests - Line: 24 _________________________ I88101MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 1 (EDIM )RS-232 SECURITYCODE : ****** ============================Request: 25 - I88102 - Comm Port 2 SettingsRequest Source: Monitor System Configuration Requests - Line: 25 _________________________ I88102MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : ****** DTR NORMAL STATE: HIGH ============================Request: 26 - I88103 - Comm Port 3 SettingsRequest Source: Monitor System Configuration Requests - Line: 26 _________________________ I88103MAY 30, 2024 8:16PORT SETTINGS: file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : ****** DTR NORMAL STATE: HIGH ============================Request: 27 - I88104 - Comm Port 4 SettingsRequest Source: Monitor System Configuration Requests - Line: 27 _________________________ I88104MAY 30, 2024 8:16 ============================Request: 28 - I88105 - Comm Port 5 SettingsRequest Source: Monitor System Configuration Requests - Line: 28 _________________________ I88105MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : ****** ============================Request: 29 - I88106 - Comm Port 6 SettingsRequest Source: Monitor System Configuration Requests - Line: 29 _________________________ I88106MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 6 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : ****** file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ============================Request: 30 - I52000 - Receiver Auto Dial Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 30 _________________________ I52000MAY 30, 2024 8:16 RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAY 16, 2018 DISABLED 2 ON DATE MAY 16, 2018 DISABLED 3 ON DATE MAY 16, 2018 DISABLED 4 ON DATE MAY 16, 2018 DISABLED 5 ON DATE MAY 16, 2018 DISABLED 6 ON DATE MAY 16, 2018 DISABLED 7 ON DATE MAY 16, 2018 DISABLED 8 WEEKLY SAT 5:04 PM ============================Request: 31 - I60100 - Tank ConfigurationRequest Source: Monitor System Configuration Requests - Line: 31 _________________________ I60100MAY 30, 2024 8:16 TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 Unleaded 87A ON 2 Unleaded 87B ON 3 Premium ON 4 Gas Additive ON ============================Request: 32 - I60200 - Tank Product LabelRequest Source: Monitor System Configuration Requests - Line: 32 _________________________ I60200MAY 30, 2024 8:16 TANK PRODUCT LABEL TANK PRODUCT LABEL 1 Unleaded 87A 2 Unleaded 87B 3 Premium 4 Gas Additive file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ============================Request: 33 - I60300 - Tank Product CodeRequest Source: Monitor System Configuration Requests - Line: 33 _________________________ I60300MAY 30, 2024 8:16 TANK PRODUCT CODE TANK PRODUCT LABEL 1 Unleaded 87A 1 2 Unleaded 87B 1 3 Premium 2 4 Gas Additive 3 ============================Request: 34 - I60900 - Tank Thermal Expansion Coefficient Request Source: Monitor System Configuration Requests - Line: 34 _________________________ I60900MAY 30, 2024 8:16 TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 Unleaded 87A 0.000700 2 Unleaded 87B 0.000700 3 Premium 0.000700 4 Gas Additive 0.000405 ============================Request: 35 - I60700 - Tank DiameterRequest Source: Monitor System Configuration Requests - Line: 35 _________________________ I60700MAY 30, 2024 8:16 TANK DIAMETER TANK PRODUCT LABEL INCHES 1 Unleaded 87A 117.15 2 Unleaded 87B 114.49 3 Premium 116.37 4 Gas Additive 47.50 ============================Request: 36 - I60A00 - Tank Full VolumeRequest Source: Monitor System Configuration Requests - Line: 36 _________________________ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] I60A00MAY 30, 2024 8:16 TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 Unleaded 87A 20 PTS 30492 2 Unleaded 87B 20 PTS 29499 3 Premium 20 PTS 30169 4 Gas Additive 4 PTS 1514 ============================Request: 37 - I60400 - Tank 1 Point Full Volume HeightRequest Source: Monitor System Configuration Requests - Line: 37 _________________________ I60400MAY 30, 2024 8:16 TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30492 2 Unleaded 87B 29499 3 Premium 30169 4 Gas Additive 1514 ============================Request: 38 - I60500 - Tank 4 Point Full, 3/4, 1/2. 1/4 VolumesRequest Source: Monitor System Configuration Requests - Line: 38 _________________________ I60500MAY 30, 2024 8:16 TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30492 25161 15967 6578 2 Unleaded 87B 29499 23616 14600 5624 3 Premium 30169 24704 15583 6328 4 Gas Additive 1514 1220 762 299 ============================Request: 39 - I60600 - Tank 20 Point Full, 95%, 90%, ...volumesRequest Source: Monitor System Configuration Requests - Line: 39 _________________________ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] I60600MAY 30, 2024 8:16 TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30492 30208 29326 28136 26730 25161 23466 21675 19814 17904 15967 14023 12091 10191 8346 6578 4912 3381 2025 903 2 Unleaded 87B 29499 28886 27882 26629 25192 23616 21931 20165 18341 16479 14600 12722 10865 9048 7294 5624 4068 2657 1438 484 3 Premium 30169 29810 28892 27685 26273 24704 23016 21237 19390 17499 15583 13663 11756 9884 8067 6328 4693 3195 1874 792 4 Gas Additive 1514 0 0 0 0 1220 0 0 0 0 762 0 0 0 0 299 0 0 0 0 ============================Request: 40 - I61500 - BIR Meter Data PresentRequest Source: Monitor System Configuration Requests - Line: 40 _________________________ I61500MAY 30, 2024 8:16 TANK PRODUCT LABEL METER DATA 1 Unleaded 87A YES 2 Unleaded 87B YES 3 Premium YES 4 Gas Additive YES ============================Request: 41 - I62F00 - Mag Probe Float SizeRequest Source: Monitor System Configuration Requests - Line: 41 _________________________ I62F00MAY 30, 2024 8:16 MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 1 Unleaded 87A 4.0 IN. 2 Unleaded 87B 4.0 IN. 3 Premium 4.0 IN. 4 Gas Additive 4.0 IN. ============================Request: 42 - I62700 - Tank Height Water warning limitRequest Source: Monitor System Configuration Requests - Line: 42 _________________________ I62700MAY 30, 2024 8:17 TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 87A 0.8 2 Unleaded 87B 0.8 3 Premium 0.8 ============================Request: 43 - I64200 - Tank Water Filter LimitRequest Source: Monitor System Configuration Requests - Line: 43 _________________________ I64200MAY 30, 2024 8:17 WATER ALARM FILTER TANK PRODUCT LABEL 1 Unleaded 87A LOW 2 Unleaded 87B LOW 3 Premium LOW ============================Request: 44 - I62400 - Tank High Water Level LimitRequest Source: Monitor System Configuration Requests - Line: 44 _________________________ I62400MAY 30, 2024 8:17 TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 87A 2.0 2 Unleaded 87B 2.0 3 Premium 2.0 ============================Request: 45 - I62800 - Tank Maximum Volume Limit file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] Request Source: Monitor System Configuration Requests - Line: 45 _________________________ I62800MAY 30, 2024 8:17 TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30493 2 Unleaded 87B 29500 3 Premium 30170 4 Gas Additive 1514 ============================Request: 46 - I62300 - Tank Overfill Level limitRequest Source: Monitor System Configuration Requests - Line: 46 _________________________ I62300MAY 30, 2024 8:17 TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 27443 2 Unleaded 87B 26550 3 Premium 27153 4 Gas Additive 1363 ============================Request: 47 - I62200 - Tank High Level LimitRequest Source: Monitor System Configuration Requests - Line: 47 _________________________ I62200MAY 30, 2024 8:17 TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 28663 2 Unleaded 87B 27730 3 Premium 28360 4 Gas Additive 1438 ============================Request: 48 - I62900 - Tank Delivery Required limitRequest Source: Monitor System Configuration Requests - Line: 48 _________________________ I62900MAY 30, 2024 8:17 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 6099 2 Unleaded 87B 5900 3 Premium 6034 4 Gas Additive 150 ============================Request: 49 - I62100 - Tank Low Level LimitRequest Source: Monitor System Configuration Requests - Line: 49 _________________________ I62100MAY 30, 2024 8:17 TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 915 2 Unleaded 87B 885 3 Premium 905 4 Gas Additive 114 ============================Request: 50 - I62600 - Tank Leak Alarm LimitRequest Source: Monitor System Configuration Requests - Line: 50 _________________________ I62600MAY 30, 2024 8:17 TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 8 2 Unleaded 87B 8 3 Premium 8 4 Gas Additive 8 ============================Request: 51 - I62500 - Tank Sudden Loss LimitRequest Source: Monitor System Configuration Requests - Line: 51 _________________________ I62500MAY 30, 2024 8:17 TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 99 2 Unleaded 87B 99 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 3 Premium 99 4 Gas Additive 99 ============================Request: 52 - I60800 - Tank TiltRequest Source: Monitor System Configuration Requests - Line: 52 _________________________ I60800MAY 30, 2024 8:17 TANK TILT TANK PRODUCT LABEL INCHES 1 Unleaded 87A 0.00 2 Unleaded 87B 0.00 3 Premium 0.00 4 Gas Additive 0.00 ============================Request: 53 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 53 _________________________ I60B00MAY 30, 2024 8:17 STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 54 - I60C00 - Tank Stick Height offsetRequest Source: Monitor System Configuration Requests - Line: 54 _________________________ I60C00MAY 30, 2024 8:17 TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 Unleaded 87A 0.00 2 Unleaded 87B 0.00 3 Premium 0.00 4 Gas Additive 0.00 ============================Request: 55 - I61200 - Tank Siphon Manifold partnersRequest Source: Monitor System Configuration Requests - Line: 55 _________________________ I61200MAY 30, 2024 8:17 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 Unleaded 87A 2 NONE 2 Unleaded 87B 1 NONE 3 Premium NONE NONE 4 Gas Additive NONE NONE ============================Request: 56 - I63600 - Tank Periodic Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 56 _________________________ I63600MAY 30, 2024 8:17 PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 24050 2 Unleaded 87B 24050 3 Premium 24050 4 Gas Additive 0 ============================Request: 57 - I62A00 - Tank Annual Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 57 _________________________ I62A00MAY 30, 2024 8:17 ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 24050 2 Unleaded 87B 24050 3 Premium 24050 4 Gas Additive 0 ============================Request: 58 - I62C00 - Tank Periodic Test TypeRequest Source: Monitor System Configuration Requests - Line: 58 _________________________ I62C00MAY 30, 2024 8:17 TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 Unleaded 87A STANDARD 2 Unleaded 87B STANDARD file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 3 Premium STANDARD 4 Gas Additive STANDARD ============================Request: 59 - I62D00 - Enable-Disable Tank Test Leak Fail AlarmsRequest Source: Monitor System Configuration Requests - Line: 59 _________________________ I62D00MAY 30, 2024 8:17 TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 Unleaded 87A GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 Unleaded 87B GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 Premium GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 Gas Additive GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ============================Request: 60 - I63100 - Tank Leak Test AveragingRequest Source: Monitor System Configuration Requests - Line: 60 _________________________ I63100MAY 30, 2024 8:17 TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 Unleaded 87A OFF OFF 2 Unleaded 87B OFF OFF 3 Premium OFF OFF 4 Gas Additive OFF OFF ============================Request: 61 - I63000 - Tank Leak Test notifyRequest Source: Monitor System Configuration Requests - Line: 61 _________________________ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] I63000MAY 30, 2024 8:17 IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 Unleaded 87A OFF 2 Unleaded 87B OFF 3 Premium OFF 4 Gas Additive OFF ============================Request: 62 - I63200 - Tank Test Siphon BreakRequest Source: Monitor System Configuration Requests - Line: 62 _________________________ I63200MAY 30, 2024 8:17 TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 Unleaded 87A OFF 2 Unleaded 87B OFF 3 Premium OFF 4 Gas Additive OFF ============================Request: 63 - I61000 - Tank delivery DelayRequest Source: Monitor System Configuration Requests - Line: 63 _________________________ I61000MAY 30, 2024 8:17 TANK DELIVERY DELAY TANK PRODUCT LABEL 1 Unleaded 87A 1 2 Unleaded 87B 1 3 Premium 1 4 Gas Additive 1 ============================Request: 64 - I63A00 - Tank low Level Threshold for Line Manifold Request Source: Monitor System Configuration Requests - Line: 64 _________________________ I63A00MAY 30, 2024 8:17 LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] TANK PRODUCT LABEL PUMP THRESHOLD 1 Unleaded 87A 10.00% 2 Unleaded 87B 10.00% 3 Premium 10.00% 4 Gas Additive 10.00% ============================Request: 65 - I61100 - Tank Leak Test Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 65 _________________________ I61100MAY 30, 2024 8:17 LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKJUN 7, 2013START TIME : DISABLEDTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED ============================Request: 66 - I61300 - CSLD Probability of DetectionRequest Source: Monitor System Configuration Requests - Line: 66 _________________________ I61300MAY 30, 2024 8:17CSLD PROBABLITY OF DETECTION ============================Request: 67 - I61400 - CSLD Climate FactorRequest Source: Monitor System Configuration Requests - Line: 67 _________________________ I61400MAY 30, 2024 8:17CSLD CLIMATE FACTOR ============================Request: 68 - I61600 - Accuchart Update SchedulingRequest Source: Monitor System Configuration Requests - Line: 68 _________________________ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] I61600MAY 30, 2024 8:17 TANK PRODUCT LABEL CAL UPDATE 1 Unleaded 87A NEVER 2 Unleaded 87B NEVER 3 Premium NEVER 4 Gas Additive NEVER ============================Request: 69 - I61A00 - In-Tank Leak Test Early StopRequest Source: Monitor System Configuration Requests - Line: 69 _________________________ I61A00MAY 30, 2024 8:17 IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 Unleaded 87A DISABLED 2 Unleaded 87B DISABLED 3 Premium DISABLED 4 Gas Additive DISABLED ============================Request: 70 - I61B00 - In-Tank Static Gross Test Auto-ConfirmRequest Source: Monitor System Configuration Requests - Line: 70 _________________________ I61B00MAY 30, 2024 8:17 IN-TANK LEAK GROSS TEST AUTO-CONFIRM ============================Request: 71 - I61C00 - CSLD Report Only modeRequest Source: Monitor System Configuration Requests - Line: 71 _________________________ I61C00MAY 30, 2024 8:17 CSLD REPORT ONLY ============================Request: 72 - I62B00 - Tank Last Annual TestRequest Source: Monitor System Configuration Requests - Line: 72 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] _________________________ I62B00MAY 30, 2024 8:17 TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 Unleaded 87A ??? 0, 0 2 Unleaded 87B ??? 0, 0 3 Premium ??? 0, 0 4 Gas Additive ??? 0, 0 ============================Request: 73 - I63300 - Leak Test Report TypeRequest Source: Monitor System Configuration Requests - Line: 73 _________________________ I63300MAY 30, 2024 8:17 LEAK TEST REPORT FORMAT: NORMAL ============================Request: 74 - I63400 - Tank HRM Reconciliation Warning limitRequest Source: Monitor System Configuration Requests - Line: 74 _________________________ I63400MAY 30, 2024 8:17 RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 0 2 Unleaded 87B 0 3 Premium 0 4 Gas Additive 0 ============================Request: 75 - I63500 - Tank HEM Reconciliation AlarmRequest Source: Monitor System Configuration Requests - Line: 75 _________________________ I63500MAY 30, 2024 8:17 RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 1 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 2 Unleaded 87B 1 3 Premium 1 4 Gas Additive 1 ============================Request: 76 - I63900 - Tank Accuchart End Shape Type and FactorRequest Source: Monitor System Configuration Requests - Line: 76 _________________________ I63900MAY 30, 2024 8:17 ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 Unleaded 87A END FACTOR: OTHEREND VALUE: 1.0 2 Unleaded 87B END FACTOR: OTHEREND VALUE: 1.0 3 Premium END FACTOR: OTHEREND VALUE: 1.0 4 Gas Additive END FACTOR: HEMISPHER ============================Request: 77 - I78000 - PLLD SetupRequest Source: Monitor System Configuration Requests - Line: 77 _________________________ I78000MAY 30, 2024 8:17 PRESSURE LINE LEAK SETUP Q 1:UNLEADED 87A TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 310 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 1:Unleaded 87A file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] DISPENSE MODE:STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:UNLEADED 87B TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 320 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 2:Unleaded 87B DISPENSE MODE:STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:PREMIUM TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 330 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 3:Premium DISPENSE MODE:STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO ============================Request: 78 - I77700 - PLLD Primary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 78 _________________________ I77700MAY 30, 2024 8:17 ============================ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] Request: 79 - I77800 - PLLD Secondary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 79 _________________________ I77800MAY 30, 2024 8:17 ============================Request: 80 - I78C00 - PLLD 0.20 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 80 _________________________ I78C00MAY 30, 2024 8:17 PRESSURE LINE LEAK 0.20 TEST SCHEDULE LINE 0.20 GPH TESTQ 1:UNLEADED 87A REPETITIVQ 2:UNLEADED 87B REPETITIVQ 3:PREMIUM REPETITIV ============================Request: 81 - I78300 - PLLD 0.10 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 81 _________________________ I78300MAY 30, 2024 8:17 PRESSURE LINE LEAK 0.10 TEST SCHEDULE LINE 0.10 GPH TESTQ 1:UNLEADED 87A AUTOQ 2:UNLEADED 87B AUTOQ 3:PREMIUM AUTO ============================Request: 82 - I78F00 - PLLD Dispense ThresholdRequest Source: Monitor System Configuration Requests - Line: 82 _________________________ I78F00MAY 30, 2024 8:17 PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSUREQ 1:UNLEADED 87A 5 PSIQ 2:UNLEADED 87B 5 PSI file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] Q 3:PREMIUM 5 PSI ============================Request: 83 - I78700 - PLLD Disable Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 83 _________________________ I78700MAY 30, 2024 8:17 PRESSURE LLD SETUP REPORT Q 1:UNLEADED 87A IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L 1:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] L18:SHORT ALARM L19:SHORT ALARM L 1:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L 1:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L18:LOW LIQUID ALARM L19:LOW LIQUID ALARM L 1:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L19:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 1:SETUP DATA WARNING s 3:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 1:COMMUNICATION ALARM s 3:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 1:SENSOR FAULT ALARM s 3:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 1:HIGH LIQUID WARNING s 3:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 1:HIGH LIQUID ALARM s 2:HIGH LIQUID ALARM s 3:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM s11:LOW LIQUID WARNING s13:LOW LIQUID WARNING s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 1:SENSOR FAULT WARN s 3:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 1:VACUUM WARNING s 3:VACUUM WARNING s 1:NO VACUUM ALARM s 2:NO VACUUM ALARM s 3:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL Q 2:UNLEADED 87B IN-TANK ALARMS T 1:HIGH WATER ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L19:SHORT ALARM L21:SHORT ALARM L 2:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L 2:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L19:LOW LIQUID ALARM L21:LOW LIQUID ALARM L 2:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L19:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 4:SETUP DATA WARNING s 5:SETUP DATA WARNING s 6:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 4:COMMUNICATION ALARM s 5:COMMUNICATION ALARM s 6:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 4:SENSOR FAULT ALARM s 5:SENSOR FAULT ALARM s 6:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 4:HIGH LIQUID WARNING s 5:HIGH LIQUID WARNING s 6:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 4:HIGH LIQUID ALARM s 5:HIGH LIQUID ALARM s 6:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] s13:HIGH LIQUID ALARM s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 4:SENSOR FAULT WARN s 5:SENSOR FAULT WARN s 6:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 4:VACUUM WARNING s 5:VACUUM WARNING s 6:VACUUM WARNING s13:VACUUM WARNING s 4:NO VACUUM ALARM s 5:NO VACUUM ALARM s 6:NO VACUUM ALARM s13:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL Q 3:PREMIUM IN-TANK ALARMS T 3:HIGH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] L22:FUEL ALARM L23:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 3:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L 3:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 3:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L22:LIQUID WARNING PRESSURE LINE LEAK file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 9:SETUP DATA WARNING s10:SETUP DATA WARNING s15:SETUP DATA WARNING s 9:COMMUNICATION ALARM s10:COMMUNICATION ALARM s15:COMMUNICATION ALARM s 9:SENSOR FAULT ALARM s10:SENSOR FAULT ALARM s15:SENSOR FAULT ALARM s15:FUEL WARNING s15:FUEL ALARM s15:WATER WARNING s15:WATER ALARM s 9:HIGH LIQUID WARNING s10:HIGH LIQUID WARNING s15:HIGH LIQUID WARNING s 9:HIGH LIQUID ALARM s10:HIGH LIQUID ALARM s15:HIGH LIQUID ALARM s15:LOW LIQUID ALARM s15:INSTALL ALARM s 9:SENSOR FAULT WARN s10:SENSOR FAULT WARN s15:SENSOR FAULT WARN s 9:VACUUM WARNING s10:VACUUM WARNING s 9:NO VACUUM ALARM s10:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ============================Request: 84 - I70200 - Liquid Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 84 _________________________ I70200MAY 30, 2024 8:18 LIQUID LABEL DEVICE LABEL 1 UNLEADED 87A ANNULAR 2 UNLEADED 87B ANNULAR 3 PREMIUM ANNULAR 4 ADDITIVE ANNULAR 5 ADDITIVE SUMP 6 ADDITIVE VENT BOX 7 8 9 DISP PAN 1-2 10 DISP PAN 3-4 11 DISP PAN 5-6 12 DISP PAN 7-8 13 DISP PAN 9-10 14 DISP PAN 11-12 15 DISP PAN 13-14 16 DISP PAN 15-16 17 UNL 87A STP BRINE 18 UNL 87A FILL 19 UNL 87B STP BRINE 20 21 UNL 87B FILL 22 91 STP BRINE 23 91 FILL 24 PERMEATOR ============================Request: 85 - I70300 - Liquid Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 85 _________________________ I70300MAY 30, 2024 8:18 LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED 87A ANNULAR DUAL POINT HYDROSTATIC 2 UNLEADED 87B ANNULAR DUAL POINT HYDROSTATIC 3 PREMIUM ANNULAR DUAL POINT HYDROSTATIC 4 ADDITIVE ANNULAR DUAL POINT HYDROSTATIC 5 ADDITIVE SUMP DW SUMP 2-1 6 ADDITIVE VENT BOX DW SUMP 2-1 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP PAN 1-2 DW SUMP 2-1 10 DISP PAN 3-4 DW SUMP 2-1 11 DISP PAN 5-6 DW SUMP 2-1 12 DISP PAN 7-8 DW SUMP 2-1 13 DISP PAN 9-10 DW SUMP 2-1 14 DISP PAN 11-12 DW SUMP 2-1 15 DISP PAN 13-14 DW SUMP 2-1 16 DISP PAN 15-16 DW SUMP 2-1 17 UNL 87A STP BRINE TRI-STATE (SINGLE FLOAT) 18 UNL 87A FILL DW SUMP 2-1 19 UNL 87B STP BRINE TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 UNL 87B FILL DW SUMP 2-1 22 91 STP BRINE TRI-STATE (SINGLE FLOAT) 23 91 FILL DW SUMP 2-1 24 PERMEATOR NORMALLY CLOSED ============================Request: 86 - I70400 - Liquid Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 86 _________________________ I70400MAY 30, 2024 8:18 LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED 87A ANNULAR ANNULAR SPACE 2 UNLEADED 87B ANNULAR ANNULAR SPACE 3 PREMIUM ANNULAR ANNULAR SPACE 4 ADDITIVE ANNULAR ANNULAR SPACE 5 ADDITIVE SUMP STP SUMP 6 ADDITIVE VENT BOX DISPENSER PAN 7 OTHER SENSORS 8 OTHER SENSORS 9 DISP PAN 1-2 DISPENSER PAN 10 DISP PAN 3-4 DISPENSER PAN 11 DISP PAN 5-6 DISPENSER PAN 12 DISP PAN 7-8 DISPENSER PAN 13 DISP PAN 9-10 DISPENSER PAN 14 DISP PAN 11-12 DISPENSER PAN 15 DISP PAN 13-14 DISPENSER PAN 16 DISP PAN 15-16 DISPENSER PAN 17 UNL 87A STP BRINE ANNULAR SPACE 18 UNL 87A FILL OTHER SENSORS 19 UNL 87B STP BRINE ANNULAR SPACE 20 OTHER SENSORS 21 UNL 87B FILL OTHER SENSORS 22 91 STP BRINE ANNULAR SPACE 23 91 FILL ANNULAR SPACE 24 PERMEATOR OTHER SENSORS file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ============================Request: 87 - I74200 - Type "A" 2 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 87 _________________________ I74200MAY 30, 2024 8:18 ============================Request: 88 - I74300 - Type "A" 2 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 88 _________________________ I74300MAY 30, 2024 8:18 ============================Request: 89 - I74400 - Type "A" 2 Wire Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 89 _________________________ I74400MAY 30, 2024 8:18 ============================Request: 90 - I74700 - Type "B" 3 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 90 _________________________ I74700MAY 30, 2024 8:18 ============================Request: 91 - I74800 - Type "B" 3 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 91 _________________________ I74800MAY 30, 2024 8:18 ============================Request: 92 - I74900 - Type "B" Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 92 _________________________ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] I74900MAY 30, 2024 8:18 ============================Request: 93 - I7BC00 - I/O Device Line Disable AssignmentsRequest Source: Monitor System Configuration Requests - Line: 93 _________________________ I7BC00MAY 30, 2024 8:18 ============================Request: 94 - I80200 - I/O Input location LabelRequest Source: Monitor System Configuration Requests - Line: 94 _________________________ I80200MAY 30, 2024 8:18 EXTERNAL INPUT LABEL DEVICE LABEL 1 ARID FAULT 2 ARID ACTIVE ============================Request: 95 - I80300 - I/O Input TypeRequest Source: Monitor System Configuration Requests - Line: 95 _________________________ I80300MAY 30, 2024 8:18 EXTERNAL INPUT TYPE INPUT NAME TYPE ORIENTATION TANK# 1 ARID FAULT VP PROCESSOR NORMALLY CLOSED 2 ARID ACTIVE VP PROCESSR2 NORMALLY OPEN ============================Request: 96 - I80400 - I/O Input Dispense modeRequest Source: Monitor System Configuration Requests - Line: 96 _________________________ I80400MAY 30, 2024 8:18 ============================ file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] Request: 97 - I80700 - I/O Relay location labelRequest Source: Monitor System Configuration Requests - Line: 97 _________________________ I80700MAY 30, 2024 8:18 RELAY LABEL DEVICE LABEL 1 OUTSIDE OVERFILL 2 WAREHOUSE V-R ALARM 3 ADDITIVE SHUTDOWN 4 5 6 ============================Request: 98 - I80900 - I/O Relay OrientationRequest Source: Monitor System Configuration Requests - Line: 98 _________________________ I80900MAY 30, 2024 8:18 RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 OUTSIDE OVERFILL NORMALLY OPEN 2 WAREHOUSE V-R ALARM NORMALLY OPEN 3 ADDITIVE SHUTDOWN NORMALLY OPEN 4 NORMALLY OPEN 5 NORMALLY OPEN 6 NORMALLY OPEN ============================Request: 99 - I80B00 - I/O Relay Tank AssignmentRequest Source: Monitor System Configuration Requests - Line: 99 _________________________ I80B00MAY 30, 2024 8:18 RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 OUTSIDE OVERFILL NONE 2 WAREHOUSE V-R ALARM NONE 3 ADDITIVE SHUTDOWN 4 4 NONE 5 NONE 6 NONE file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ============================Request: 100 - I80A00 - I/O Relay TypeRequest Source: Monitor System Configuration Requests - Line: 100 _________________________ I80A00MAY 30, 2024 8:18 RELAY TYPE RELAY DESIGNATION TYPE 1 OUTSIDE OVERFILL STANDARD 2 WAREHOUSE V-R ALARM STANDARD 3 ADDITIVE SHUTDOWN PUMP CONTROL OUTPUT 4 STANDARD 5 STANDARD 6 STANDARD ============================Request: 101 - I80C00 - I/O External input TypeRequest Source: Monitor System Configuration Requests - Line: 101 _________________________ I80C00MAY 30, 2024 8:18 EXTERNAL INPUT TYPE INPUT NAME TYPE ORIENTATION TANK# 1 ARID FAULT VP PROCESSOR NORMALLY CLOSED 2 ARID ACTIVE VP PROCESSR2 NORMALLY OPEN ============================Request: 102 - I80800 - I/O Relay Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 102 _________________________ I80800MAY 30, 2024 8:18 RELAY SETUP REPORT R 1:OUTSIDE OVERFILL TYPE: STANDARDNORMALLY OPEN TANK #: NONE file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 2:WAREHOUSE V-R ALARM TYPE: STANDARDNORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ALL:LOW LIQUID ALARM ALL:TEMPERATURE WARNING ALL:RELAY ACTIVE ALL:INSTALL ALARM ALL:SENSOR FAULT WARN ALL:VACUUM WARNING ALL:NO VACUUM ALARM ALL:BATTERY WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 3:ADDITIVE SHUTDOWN TYPE: PUMP CONTROL OUTPUTTANK #: 4 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] IN-TANK ALARMS T 4:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 4:HIGH LIQUID ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L 4:LOW LIQUID ALARM L 5:LOW LIQUID ALARM L 6:LOW LIQUID ALARM L 4:LIQUID WARNING L 5:LIQUID WARNING L 6:LIQUID WARNING SMARTSENSOR ALARMS s12:COMMUNICATION ALARM s12:SENSOR FAULT ALARM s12:HIGH LIQUID WARNING s12:HIGH LIQUID ALARM s12:SENSOR FAULT WARN s12:VACUUM WARNING s12:NO VACUUM ALARM R 4: TYPE: STANDARDNORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5: TYPE: STANDARDNORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 6: TYPE: STANDARDNORMALLY OPEN TANK #: NONE file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] - NO ALARM ASSIGNMENTS - ============================Request: 103 - I79000 - DIM Software RevisionRequest Source: Monitor System Configuration Requests - Line: 103 _________________________ I79000MAY 30, 2024 8:19 EDIM:1 VR:349806-002-A 5 TD:16.12.14.16.18 ============================Request: 104 - I79100 - Mechanical Dispenser Interface StringRequest Source: Monitor System Configuration Requests - Line: 104 _________________________ I79100MAY 30, 2024 8:19 ============================Request: 105 - I72300 - Smart Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 105 _________________________ I72300MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 UNL 87A PRODUCT LINE VAC SENSOR02 VAPOR LINE VAC SENSOR03 UNL 87A VENT LINE VAC SENSOR04 UNL 87B PRODUCT LINE VAC SENSOR05 UNL 87B SIPHON LINE VAC SENSOR06 UNL 87B VENT LINE VAC SENSOR07 PRESSURE SENSOR 3-4 VAPOR PRESSURE08 ATP ATM P SENSOR09 PREMIUM PRODUCT LINE VAC SENSOR10 PREMIUM VENT LINE VAC SENSOR11 87A STP SUMP MAG SENSOR12 ADDITIVE PRODUCT VAC VAC SENSOR file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 13 87B STP SUMP MAG SENSOR14 ADDITIVE VENT VAC VAC SENSOR15 PREMIUM STP SUMP MAG SENSOR16 UNKNOWN17 DISP 1-2 AIR FLOW METER18 DISP 3-4 AIR FLOW METER19 DISP 5-6 AIR FLOW METER20 DISP 7-8 AIR FLOW METER21 DISP 9-10 AIR FLOW METER22 DISP 11-12 AIR FLOW METER23 DISP 13-14 AIR FLOW METER24 DISP 15-16 AIR FLOW METER25 UNKNOWN26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN38 UNKNOWN39 UNKNOWN40 UNKNOWN ============================Request: 106 - IV4E00 - ISD EVR TypeRequest Source: Monitor System Configuration Requests - Line: 106 _________________________ IV4E00MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC ============================Request: 107 - IV4F00 - ISD Nozzle TypeRequest Source: Monitor System Configuration Requests - Line: 107 _________________________ IV4F00MAY 30, 2024 8:19 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 ============================Request: 108 - IV4000 - Vapor Processor TypeRequest Source: Monitor System Configuration Requests - Line: 108 _________________________ IV4000MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA VAPOR PROCESSOR TYPEARID PERMEATOR ============================Request: 109 - IV4700 - ISD Assessment Start and Post DelayRequest Source: Monitor System Configuration Requests - Line: 109 _________________________ IV4700MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA ASSESSMENT TIMESTART TIME: 05:00TIME DELAY MINUTES: 1 ============================Request: 110 - IV5200 - High ORVR ConfigurationRequest Source: Monitor System Configuration Requests - Line: 110 _________________________ IV5200MAY 30, 2024 8:19 279395 COSTCO #643 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 4900 Panama Lane Bakersfield, CA ACCEPT HIGH ORVR: YES ============================Request: 111 - IV4A00 - ISD Hose TableRequest Source: Monitor System Configuration Requests - Line: 111 _________________________ IV4A00MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND2 02 02 02 01 UU BLEND2 03 03 03 02 UU BLEND2 04 04 04 02 UU BLEND2 05 05 05 03 UU BLEND2 06 06 06 03 UU BLEND2 07 07 07 04 UU BLEND2 08 08 08 04 UU BLEND2 09 09 09 05 UU BLEND2 10 10 10 05 UU BLEND2 11 11 11 06 UU BLEND2 12 12 12 06 UU BLEND2 13 13 13 07 UU BLEND2 14 14 14 07 UU BLEND2 15 15 15 08 UU BLEND2 16 16 16 08 UU BLEND2 ============================Request: 112 - IV4B00 - ISD Grade TableRequest Source: Monitor System Configuration Requests - Line: 112 _________________________ IV4B00MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA PRODUCT/HOSE MAP TABLE file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 00/01 01/01 xx/xx xx/xx02 01 00/02 01/02 xx/xx xx/xx03 02 00/03 01/03 xx/xx xx/xx04 02 00/04 01/04 xx/xx xx/xx05 03 00/05 01/05 xx/xx xx/xx06 03 00/06 01/06 xx/xx xx/xx07 04 00/07 01/07 xx/xx xx/xx08 04 00/08 01/08 xx/xx xx/xx09 05 00/09 01/09 xx/xx xx/xx10 05 00/10 01/10 xx/xx xx/xx11 06 00/11 01/11 xx/xx xx/xx12 06 00/12 01/12 xx/xx xx/xx13 07 00/13 01/13 xx/xx xx/xx14 07 00/14 01/14 xx/xx xx/xx15 08 00/15 01/15 xx/xx xx/xx16 08 00/16 01/16 xx/xx xx/xx ============================Request: 113 - IV4900 - ISD Hose Label TableRequest Source: Monitor System Configuration Requests - Line: 113 _________________________ IV4900MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA LABEL TABLEID LABEL01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 ============================Request: 114 - IV1000 - ISD VersionRequest Source: Monitor System Configuration Requests - Line: 114 _________________________ IV1000MAY 30, 2024 8:19 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] ISD VERSION: 01.07 ============================| Next Request Source: || Alarm History Request+==========================+Request: 115 - I10200 - System ConfigurationRequest Source: Alarm History Request - Line: 1 _________________________ I10200MAY 30, 2024 8:22 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162964 163697 2 INTERSTITIAL BD 201401 201846 3 INTERSTITIAL BD 200634 201261 4 7SMARTSENSOR BD 506739 506756 5 INTERSTITIAL BD 200378 200886 6 PLLD SENSOR BD 3871 3885 7 8SMARTSENSOR BD 39263 39426 8 8SMARTSENSOR BD 39329 39316 9 RELAY BOARD 14942 14985 10 PLLD POWER BD 100017 100130 11 UNUSED 5042151 5016072 12 UNUSED 5040668 5015271 13 STP SENSE BOARD 32875 32918 14 COMBO I/O BOARD 9891 9898 15 UNUSED 5043847 5016028 16 UNUSED 5034632 5008629 COMM 1 ELEC DISP INT. 100062 100333 COMM 2 SERIAL SAT BD 478400 480059 COMM 3 SERIAL SAT BD 483865 482579 COMM 4 UNUSED 5047241 5008997 COMM 5 RS485 SERIAL BD 68067 68079 COMM 6 RS232 SERIAL BD 14834 14877 ============================Request: 116 - I90200 - System Revision LevelRequest Source: Alarm History Request - Line: 2 _________________________ I90200MAY 30, 2024 8:22SOFTWARE REVISION LEVELVERSION 336.02 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-164-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 117 - I11100 - Priority Alarm HistoryRequest Source: Alarm History Request - Line: 3 _________________________ I11100MAY 30, 2024 8:22 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMEI 1 INPUT ARID FAULT EXTERN INPUT ALARM CLEAR MAY 30 2024 8:08I 1 INPUT ARID FAULT EXTERN INPUT ALARM ALARM MAY 30 2024 8:07Q 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 7:52Q 3 OTHER PREMIUM GROSS LINE FAIL CLEAR MAY 30 2024 7:52Q 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 7:51Q 2 OTHER UNLEADED 87B GROSS LINE FAIL CLEAR MAY 30 2024 7:51Q 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 7:51Q 1 OTHER UNLEADED 87A GROSS LINE FAIL CLEAR MAY 30 2024 7:51Q 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM ALARM MAY 30 2024 7:37Q 1 OTHER UNLEADED 87A GROSS LINE FAIL ALARM MAY 30 2024 7:37Q 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM ALARM MAY 30 2024 7:33Q 2 OTHER UNLEADED 87B GROSS LINE FAIL ALARM MAY 30 2024 7:33Q 3 OTHER PREMIUM PLLD SHUTDOWN ALARM ALARM MAY 30 2024 7:25Q 3 OTHER PREMIUM GROSS LINE FAIL ALARM MAY 30 2024 7:25L 6 DISP PAN ADDITIVE VENT BOX FUEL ALARM CLEAR MAY 30 2024 7:06L 6 DISP PAN ADDITIVE VENT BOX SENSOR OUT ALARM CLEAR MAY 30 2024 7:05L 6 DISP PAN ADDITIVE VENT BOX FUEL ALARM ALARM MAY 30 2024 7:05T 4 TANK Gas Additive OVERFILL ALARM CLEAR MAY 30 2024 7:04L 6 DISP PAN ADDITIVE VENT BOX LOW LIQUID ALARM CLEAR MAY 30 2024 7:04L 6 DISP PAN ADDITIVE VENT BOX SENSOR OUT ALARM ALARM MAY 30 2024 7:04L 6 DISP PAN ADDITIVE VENT BOX LOW LIQUID ALARM ALARM MAY 30 2024 7:04T 4 TANK Gas Additive OVERFILL ALARM ALARM MAY 30 2024 7:02s12 OTHER ADDITIVE PRODUCT VAC NO VACUUM ALARM CLEAR MAY 30 2024 7:01s14 OTHER ADDITIVE VENT VAC NO VACUUM ALARM CLEAR MAY 30 2024 7:01 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] s12 OTHER ADDITIVE PRODUCT VAC HIGH LIQUID ALARM CLEAR MAY 30 2024 7:00s12 OTHER ADDITIVE PRODUCT VAC NO VACUUM ALARM ALARM MAY 30 2024 7:00s14 OTHER ADDITIVE VENT VAC HIGH LIQUID ALARM CLEAR MAY 30 2024 7:00s14 OTHER ADDITIVE VENT VAC NO VACUUM ALARM ALARM MAY 30 2024 7:00s12 OTHER ADDITIVE PRODUCT VAC HIGH LIQUID ALARM ALARM MAY 30 2024 7:00s14 OTHER ADDITIVE VENT VAC HIGH LIQUID ALARM ALARM MAY 30 2024 7:00L 5 STP SUMP ADDITIVE SUMP FUEL ALARM CLEAR MAY 30 2024 7:00L 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM CLEAR MAY 30 2024 6:59L 5 STP SUMP ADDITIVE SUMP FUEL ALARM ALARM MAY 30 2024 6:59L 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM ALARM MAY 30 2024 6:59L 5 STP SUMP ADDITIVE SUMP LOW LIQUID ALARM CLEAR MAY 30 2024 6:58L 5 STP SUMP ADDITIVE SUMP LOW LIQUID ALARM ALARM MAY 30 2024 6:58L 4 ANNULAR ADDITIVE ANNULAR HIGH LIQUID ALARM CLEAR MAY 30 2024 6:58L 4 ANNULAR ADDITIVE ANNULAR LOW LIQUID ALARM CLEAR MAY 30 2024 6:57L 4 ANNULAR ADDITIVE ANNULAR HIGH LIQUID ALARM ALARM MAY 30 2024 6:57L 4 ANNULAR ADDITIVE ANNULAR LOW LIQUID ALARM ALARM MAY 30 2024 6:57Q 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 6:55Q 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 6:55Q 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 6:55L15 DISP PAN DISP PAN 13-14 FUEL ALARM CLEAR MAY 30 2024 6:55L15 DISP PAN DISP PAN 13-14 FUEL ALARM ALARM MAY 30 2024 6:55Q 3 OTHER PREMIUM PLLD SHUTDOWN ALARM ALARM MAY 30 2024 6:55Q 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM ALARM MAY 30 2024 6:55Q 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM ALARM MAY 30 2024 6:55Q 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 6:55Q 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM CLEAR MAY 30 2024 6:55 ============================Request: 118 - I11200 - Non-Priority Alarm historyRequest Source: Alarm History Request - Line: 4 _________________________ I11200MAY 30, 2024 8:22 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA NON-PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMET 1 TANK Unleaded 87A HIGH PRODUCT ALARM CLEAR MAY 30 2024 6:33T 1 TANK Unleaded 87A HIGH PRODUCT ALARM ALARM MAY 30 2024 6:31T 3 TANK Premium LOW TEMP WARNING CLEAR MAY 30 2024 6:16T 3 TANK Premium LOW TEMP WARNING ALARM MAY 30 2024 6:15s13 OTHER 87B STP SUMP WATER WARNING CLEAR MAY 30 2024 6:15s13 OTHER 87B STP SUMP WATER WARNING ALARM MAY 30 2024 6:14s15 OTHER PREMIUM STP SUMP WATER WARNING CLEAR MAY 30 2024 6:11s15 OTHER PREMIUM STP SUMP WATER WARNING ALARM MAY 30 2024 6:11h 3 OTHER FP3: BLEND2 DEGRD COLLECT WARN CLEAR MAY 28 2024 11:13 SYSTEM PRINTER ERROR CLEAR MAY 25 2024 11:08 SYSTEM PAPER OUT CLEAR MAY 25 2024 11:08 SYSTEM PRINTER ERROR ALARM MAY 25 2024 11:08 SYSTEM PAPER OUT ALARM MAY 25 2024 11:08 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] h 3 OTHER FP3: BLEND2 DEGRD COLLECT WARN ALARM MAY 24 2024 5:01h 4 OTHER FP4: BLEND2 DEGRD COLLECT WARN CLEAR MAY 23 2024 10:54 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:38 SYSTEM PAPER OUT CLEAR MAY 22 2024 8:38 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:38 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:34 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:34 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:33 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:33 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:33 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:33 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:33 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:33 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:32 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:32 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:32 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:32 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:32 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:32 SYSTEM PAPER OUT ALARM MAY 22 2024 8:32 SYSTEM PRINTER ERROR CLEAR MAY 22 2024 8:31 SYSTEM PRINTER ERROR ALARM MAY 22 2024 8:31h 4 OTHER FP4: BLEND2 DEGRD COLLECT WARN ALARM MAY 20 2024 5:01 SYSTEM PAPER OUT CLEAR MAY 18 2024 16:14 SYSTEM PAPER OUT ALARM MAY 18 2024 16:13 SYSTEM PAPER OUT CLEAR MAY 18 2024 11:06 SYSTEM PAPER OUT ALARM MAY 18 2024 11:06h12 OTHER FP12: BLEND2 DEGRD COLLECT WARN CLEAR MAY 14 2024 5:00h12 OTHER FP12: BLEND2 DEGRD COLLECT WARN ALARM MAY 13 2024 5:01 SYSTEM PRINTER ERROR CLEAR MAY 10 2024 19:38 SYSTEM PAPER OUT CLEAR MAY 10 2024 19:38 SYSTEM PRINTER ERROR ALARM MAY 10 2024 19:37 SYSTEM PAPER OUT ALARM MAY 10 2024 19:37h 4 OTHER FP4: BLEND2 DEGRD COLLECT WARN CLEAR MAY 7 2024 5:00h 4 OTHER FP4: BLEND2 DEGRD COLLECT WARN ALARM MAY 6 2024 5:01h11 OTHER FP11: BLEND2 DEGRD COLLECT WARN CLEAR MAY 6 2024 5:00 SYSTEM PAPER OUT CLEAR MAY 3 2024 20:45 ============================Request: 119 - I20600 - In-Tank Alarm historyRequest Source: Alarm History Request - Line: 5 _________________________ I20600MAY 30, 2024 8:22 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA TANK ALARM HISTORY TANK 1 Unleaded 87A file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] OVERFILL ALARM MAY 30, 2024 6:32 MAR 5, 2024 22:07 JAN 20, 2024 2:21 HIGH PRODUCT ALARM MAY 30, 2024 6:31 MAR 5, 2024 22:04 PROBE OUT MAY 30, 2024 6:32 MAY 30, 2024 6:28 MAR 5, 2024 22:08 DELIVERY NEEDED SEP 6, 2022 20:41 TANK 2 Unleaded 87B OVERFILL ALARM MAY 30, 2024 6:23 MAR 5, 2024 22:07 MAY 24, 2023 9:16 PROBE OUT MAY 30, 2024 6:24 MAY 30, 2024 6:20 MAR 5, 2024 22:08 LOW TEMP WARNING MAR 5, 2024 22:10 TANK 3 Premium OVERFILL ALARM MAY 30, 2024 6:16 MAR 29, 2024 21:48 MAR 29, 2024 21:43 HIGH PRODUCT ALARM MAR 5, 2024 22:05 PROBE OUT MAY 30, 2024 6:17 MAY 30, 2024 6:14 MAR 5, 2024 22:09 DELIVERY NEEDED OCT 14, 2023 18:25 OCT 13, 2023 21:00 JUL 14, 2023 15:03 LOW TEMP WARNING MAY 30, 2024 6:15 MAR 5, 2024 22:05 TANK 4 Gas Additive OVERFILL ALARM MAY 30, 2024 7:02 MAR 5, 2024 20:53 MAY 24, 2023 9:28 SUDDEN LOSS ALARM MAR 5, 2024 20:55 HIGH PRODUCT ALARM MAR 15, 2023 20:26 PROBE OUT MAR 5, 2024 21:42 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 ============================Request: 120 - I38200 - Pressure line Leak Alarm HistoryRequest Source: Alarm History Request - Line: 6 _________________________ I38200MAY 30, 2024 8:23 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:UNLEADED 87A MAY 30, 2024 7:37 PLLD SHUTDOWN ALARM MAY 30, 2024 7:37 GROSS LINE FAIL MAY 30, 2024 6:55 PLLD SHUTDOWN ALARM MAY 30, 2024 6:54 PLLD SHUTDOWN ALARM MAY 30, 2024 6:54 PLLD SHUTDOWN ALARM MAY 30, 2024 6:53 PLLD SHUTDOWN ALARM MAY 30, 2024 6:52 PLLD SHUTDOWN ALARM MAY 30, 2024 6:52 PLLD SHUTDOWN ALARM MAY 30, 2024 6:51 PLLD SHUTDOWN ALARM MAY 30, 2024 6:51 PLLD SHUTDOWN ALARM Q 2:UNLEADED 87B MAY 30, 2024 7:33 PLLD SHUTDOWN ALARM MAY 30, 2024 7:33 GROSS LINE FAIL file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] MAY 30, 2024 6:55 PLLD SHUTDOWN ALARM MAY 30, 2024 6:54 PLLD SHUTDOWN ALARM MAY 30, 2024 6:54 PLLD SHUTDOWN ALARM MAY 30, 2024 6:53 PLLD SHUTDOWN ALARM MAY 30, 2024 6:52 PLLD SHUTDOWN ALARM MAY 30, 2024 6:52 PLLD SHUTDOWN ALARM MAY 30, 2024 6:51 PLLD SHUTDOWN ALARM MAY 30, 2024 6:51 PLLD SHUTDOWN ALARM Q 3:PREMIUM MAY 30, 2024 7:25 PLLD SHUTDOWN ALARM MAY 30, 2024 7:25 GROSS LINE FAIL MAY 30, 2024 6:55 PLLD SHUTDOWN ALARM MAY 30, 2024 6:54 PLLD SHUTDOWN ALARM MAY 30, 2024 6:54 PLLD SHUTDOWN ALARM MAY 30, 2024 6:53 PLLD SHUTDOWN ALARM MAY 30, 2024 6:52 PLLD SHUTDOWN ALARM MAY 30, 2024 6:52 PLLD SHUTDOWN ALARM MAY 30, 2024 6:51 PLLD SHUTDOWN ALARM MAY 30, 2024 6:51 PLLD SHUTDOWN ALARM ============================Request: 121 - I30200 - Liquid Sensor Alarm historyRequest Source: Alarm History Request - Line: 7 _________________________ I30200MAY 30, 2024 8:23 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED 87A ANNULAR MAY 30, 2024 5:59 HIGH LIQUID ALARM MAY 30, 2024 5:59 LOW LIQUID ALARM MAY 30, 2024 5:57 SENSOR OUT ALARM 2 UNLEADED 87B ANNULAR MAY 30, 2024 6:02 HIGH LIQUID ALARM MAY 30, 2024 6:02 LOW LIQUID ALARM MAY 30, 2024 5:57 SENSOR OUT ALARM 3 PREMIUM ANNULAR MAY 30, 2024 6:05 HIGH LIQUID ALARM MAY 30, 2024 6:05 LOW LIQUID ALARM MAY 30, 2024 5:57 SENSOR OUT ALARM 4 ADDITIVE ANNULAR MAY 30, 2024 6:57 HIGH LIQUID ALARM MAY 30, 2024 6:57 LOW LIQUID ALARM MAY 30, 2024 5:57 SENSOR OUT ALARM 5 ADDITIVE SUMP file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] MAY 30, 2024 6:59 FUEL ALARM MAY 30, 2024 6:59 SENSOR OUT ALARM MAY 30, 2024 6:58 LOW LIQUID ALARM 6 ADDITIVE VENT BOX MAY 30, 2024 7:05 FUEL ALARM MAY 30, 2024 7:04 SENSOR OUT ALARM MAY 30, 2024 7:04 LOW LIQUID ALARM 9 DISP PAN 1-2 MAY 30, 2024 6:36 FUEL ALARM MAY 30, 2024 6:35 SENSOR OUT ALARM MAY 30, 2024 6:35 LOW LIQUID ALARM 10 DISP PAN 3-4 MAY 30, 2024 6:35 FUEL ALARM MAY 30, 2024 6:34 SENSOR OUT ALARM MAY 30, 2024 6:33 LOW LIQUID ALARM 11 DISP PAN 5-6 MAY 30, 2024 6:48 FUEL ALARM MAY 30, 2024 6:48 SENSOR OUT ALARM MAY 30, 2024 6:47 LOW LIQUID ALARM 12 DISP PAN 7-8 MAY 30, 2024 6:46 LOW LIQUID ALARM MAY 30, 2024 6:46 FUEL ALARM MAY 30, 2024 6:45 SENSOR OUT ALARM 13 DISP PAN 9-10 MAY 30, 2024 6:50 FUEL ALARM MAY 30, 2024 6:49 SENSOR OUT ALARM MAY 30, 2024 6:49 LOW LIQUID ALARM 14 DISP PAN 11-12 MAY 30, 2024 6:51 FUEL ALARM MAY 30, 2024 6:51 SENSOR OUT ALARM MAY 30, 2024 6:50 LOW LIQUID ALARM 15 DISP PAN 13-14 MAY 30, 2024 6:55 FUEL ALARM MAY 30, 2024 6:54 SENSOR OUT ALARM MAY 30, 2024 6:54 LOW LIQUID ALARM 16 DISP PAN 15-16 MAY 30, 2024 6:53 FUEL ALARM MAY 30, 2024 6:52 SENSOR OUT ALARM MAY 30, 2024 6:52 LOW LIQUID ALARM 17 UNL 87A STP BRINE MAY 30, 2024 6:11 FUEL ALARM MAY 30, 2024 5:57 SENSOR OUT ALARM MAR 5, 2024 21:47 FUEL ALARM 18 UNL 87A FILL MAY 30, 2024 6:01 FUEL ALARM MAY 30, 2024 6:00 SENSOR OUT ALARM MAY 30, 2024 6:00 LOW LIQUID ALARM 19 UNL 87B STP BRINE MAY 30, 2024 6:11 FUEL ALARM MAY 30, 2024 5:57 SENSOR OUT ALARM MAR 5, 2024 21:53 FUEL ALARM 21 UNL 87B FILL MAY 30, 2024 6:04 FUEL ALARM MAY 30, 2024 6:03 SENSOR OUT ALARM MAY 30, 2024 6:03 LOW LIQUID ALARM 22 91 STP BRINE MAY 30, 2024 6:10 FUEL ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] MAY 30, 2024 5:57 SENSOR OUT ALARM MAR 5, 2024 21:58 FUEL ALARM 23 91 FILL MAY 30, 2024 6:07 SENSOR OUT ALARM MAY 30, 2024 6:07 FUEL ALARM MAY 30, 2024 6:06 SENSOR OUT ALARM ============================Request: 122 - I31600 - Smart Sensor Alarm historyRequest Source: Alarm History Request - Line: 8 _________________________ I31600MAY 30, 2024 8:23 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 87A PRODUCT LINE MAY 30, 2024 6:27 NO VACUUM ALARM MAY 30, 2024 6:25 HIGH LIQUID ALARM MAR 5, 2024 21:55 NO VACUUM ALARM 2 VAPOR LINE MAY 30, 2024 6:26 NO VACUUM ALARM MAY 30, 2024 6:25 HIGH LIQUID ALARM MAR 5, 2024 21:54 NO VACUUM ALARM 3 UNL 87A VENT LINE MAY 30, 2024 6:26 NO VACUUM ALARM MAY 30, 2024 6:25 HIGH LIQUID ALARM MAR 5, 2024 21:55 NO VACUUM ALARM 4 UNL 87B PRODUCT LINE MAY 30, 2024 6:19 NO VACUUM ALARM MAY 30, 2024 6:18 HIGH LIQUID ALARM MAR 5, 2024 21:59 NO VACUUM ALARM 5 UNL 87B SIPHON LINE MAY 30, 2024 6:19 NO VACUUM ALARM MAY 30, 2024 6:18 HIGH LIQUID ALARM MAR 5, 2024 21:59 NO VACUUM ALARM 6 UNL 87B VENT LINE MAY 30, 2024 6:19 NO VACUUM ALARM MAY 30, 2024 6:18 HIGH LIQUID ALARM MAR 5, 2024 22:00 NO VACUUM ALARM 7 PRESSURE SENSOR 3-4 8 ATP 9 PREMIUM PRODUCT LINE MAY 30, 2024 6:13 NO VACUUM ALARM MAY 30, 2024 6:12 HIGH LIQUID ALARM MAR 5, 2024 21:50 NO VACUUM ALARM 10 PREMIUM VENT LINE MAY 30, 2024 6:13 NO VACUUM ALARM file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] MAY 30, 2024 6:12 HIGH LIQUID ALARM MAR 5, 2024 21:50 NO VACUUM ALARM 11 87A STP SUMP MAY 30, 2024 6:16 WATER ALARM MAY 30, 2024 6:15 INSTALL ALARM MAR 5, 2024 21:48 WATER WARNING 12 ADDITIVE PRODUCT VAC MAY 30, 2024 7:00 NO VACUUM ALARM MAY 30, 2024 7:00 HIGH LIQUID ALARM MAR 5, 2024 20:51 NO VACUUM ALARM 13 87B STP SUMP MAY 30, 2024 6:14 WATER WARNING MAY 30, 2024 6:13 INSTALL ALARM MAY 28, 2024 10:05 COMMUNICATION ALARM 14 ADDITIVE VENT VAC MAY 30, 2024 7:00 NO VACUUM ALARM MAY 30, 2024 7:00 HIGH LIQUID ALARM MAR 5, 2024 20:51 NO VACUUM ALARM 15 PREMIUM STP SUMP MAY 30, 2024 6:11 WATER WARNING MAY 30, 2024 6:11 INSTALL ALARM MAY 28, 2024 10:05 COMMUNICATION ALARM 17 DISP 1-2 18 DISP 3-4 19 DISP 5-6 20 DISP 7-8 JUL 17, 2023 14:01 COMMUNICATION ALARM 21 DISP 9-10 SEP 13, 2023 9:15 COMMUNICATION ALARM AUG 31, 2022 9:21 COMMUNICATION ALARM 22 DISP 11-12 23 DISP 13-14 24 DISP 15-16 ============================Request: 123 - I40200 - Input Alarm HistoryRequest Source: Alarm History Request - Line: 9 _________________________ I40200MAY 30, 2024 8:23 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA INPUT LOCATION 1 ARID FAULT MAY 30, 2024 8:07 EXTERN INPUT ALARM MAR 5, 2024 22:33 EXTERN INPUT ALARM MAR 5, 2024 22:32 EXTERN INPUT ALARM MAY 30, 2024 8:08 EXTERN INPUT NORMAL MAR 5, 2024 22:34 EXTERN INPUT NORMAL MAR 5, 2024 22:32 EXTERN INPUT NORMAL file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] 2 ARID ACTIVE ============================Request: 124 - I40300 - Input-Generator Alarm HistoryRequest Source: Alarm History Request - Line: 10 _________________________ I40300MAY 30, 2024 8:23 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA INPUT / GENERATOR ALARM HISTORY REPORT INPUT LOCATION 1 ARID FAULT MAY 30, 2024 8:07 EXTERN INPUT ALARM MAR 5, 2024 22:33 EXTERN INPUT ALARM MAR 5, 2024 22:32 EXTERN INPUT ALARM MAY 30, 2024 8:08 EXTERN INPUT NORMAL MAR 5, 2024 22:34 EXTERN INPUT NORMAL MAR 5, 2024 22:32 EXTERN INPUT NORMAL 2 ARID ACTIVE ============================Request: 125 - I34200 - Type A 2 Wire CL Alarm HistoryRequest Source: Alarm History Request - Line: 11 _________________________ I34200MAY 30, 2024 8:23 ============================Request: 126 - I34700 - Type B 3 Wire CL Alarm HistoryRequest Source: Alarm History Request - Line: 12 _________________________ I34700MAY 30, 2024 8:23 ============================Request: 127 - IV0100 - ISD Alarm Status Request Source: Alarm History Request - Line: 13 _________________________ IV0100 file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] MAY 30, 2024 8:23 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSISTISD TYPE: 01.07VAPOR PROCESSOR TYPE: ARID PERMEATOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% VAPOR PROCESSOR :PASS WARNING ALARMSDATE TIME DESCRIPTION READING VALUE24-05-27 05:01:09 A/L RATIO DEGRADATION FP 3 BLEND2 0.7924-05-26 05:01:09 A/L RATIO DEGRADATION FP 3 BLEND2 0.7824-05-25 05:01:09 A/L RATIO DEGRADATION FP 3 BLEND2 0.7524-05-24 05:01:15 A/L RATIO DEGRADATION FP 3 BLEND2 0.7524-05-23 05:01:20 A/L RATIO DEGRADATION FP 4 BLEND2 0.8124-05-22 05:01:09 A/L RATIO DEGRADATION FP 4 BLEND2 0.7924-05-21 05:01:09 A/L RATIO DEGRADATION FP 4 BLEND2 0.7824-05-20 05:01:09 A/L RATIO DEGRADATION FP 4 BLEND2 0.7924-05-13 05:01:19 A/L RATIO DEGRADATION FP12 BLEND2 0.7824-05-06 05:01:19 A/L RATIO DEGRADATION FP 4 BLEND2 0.81 FAILURE ALARMSDATE TIME DESCRIPTION READING VALUE21-09-22 05:01:29 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 13.18 SHUTDOWN & MISCELLANEOUS EVENTSDATE TIME DESCRIPTION ACTION/NAME24-05-28 11:13:13 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 24-05-23 10:54:40 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 24-03-10 03:00:00 TIME CHANGE DETECTED AT: 24-03-10 02:00:1324-02-05 11:11:30 COLLECTION TEST HH11 GRADE TEST MANUALLY CLEARED 24-01-10 10:11:28 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 24-01-10 05:01:14 READINESS ISD:PP EVR:PPP ISD & EVR READY24-01-09 16:02:24 READINESS ISD:PP EVR:NNN EVR READINESS PENDING24-01-09 16:02:24 ISD STARTUP 24-01-09 16:00:04 ISD SHUTDOWN 24-01-08 05:01:26 READINESS ISD:PP EVR:PPP ISD & EVR READY End of Report: 240530 +============================================================================| Monitoring System Report Saved at: Thursday, May 30, 2024 - 8:29:16 AM| (Report Saved Date/Time from PC Clock)| Using Monitoring System Report Utility by FASTECH | file:///C/...co%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Alarm%20History.txt[5/30/2024 10:37:47 AM] | Version: Version 6.0.0.100 |+============================================================================ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] +=============================================================+| Monitoring System Report using Report Utility by FASTECH || Version: Version 6.0.0.100 |+=============================================================+ Connected on PC Port: COM3 Settings: 9600 Odd 7, 1 Connect Time/Date from PC Clock: Thursday, May 30, 2024 - 8:21:44 AM Connect Date from Monitoring System: 240530Connect Time from Monitoring System Clock: 08:16 Site Label: 279395 COSTCO #6434900 Panama LaneBakersfield, CA ============================Request: 1 - 200 - Site LocationRequest Source: Monitor System Configuration Requests - Line: 1 _________________________ 200279395 COSTCO #643 4900 Panama Lane Bakersfield, CA MAY 30, 2024 8:16 TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 Unleaded 87A 22277 78.09 0.0 75.4 8215 2 Unleaded 87B 21414 78.44 0.0 74.8 8085 3 Premium 24600 86.91 0.0 73.9 5569 4 Gas Additive 876 26.59 88.7 638 ============================Request: 2 - I90500 - System Revision LevelRequest Source: Monitor System Configuration Requests - Line: 2 _________________________ I90500MAY 30, 2024 8:16SOFTWARE REVISION LEVELVERSION 336.02SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-164-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 3 - I50500 - System Type & languageRequest Source: Monitor System Configuration Requests - Line: 3 _________________________ I50500MAY 30, 2024 8:16 SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S.SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMON DD YYYY HH:MM:SS ============================Request: 4 - I50201 - Shift Start Time 1Request Source: Monitor System Configuration Requests - Line: 4 _________________________ I50201MAY 30, 2024 8:16 SHIFT TIME 1 : DISABLED ============================Request: 5 - I50202 - Shift Start Time 2Request Source: Monitor System Configuration Requests - Line: 5 _________________________ I50202MAY 30, 2024 8:16 SHIFT TIME 2 : DISABLED ============================Request: 6 - I50203 - Shift Start Time 3Request Source: Monitor System Configuration Requests - Line: 6 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] _________________________ I50203MAY 30, 2024 8:16 SHIFT TIME 3 : DISABLED ============================Request: 7 - I50204 - Shift Start Time 4Request Source: Monitor System Configuration Requests - Line: 7 _________________________ I50204MAY 30, 2024 8:16 SHIFT TIME 4 : DISABLED ============================Request: 8 - I54600 - Tank Periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 8 _________________________ I54600MAY 30, 2024 8:16 TANK PER TST NEEDED WRN: DISABLED ============================Request: 9 - I54900 - Tank Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 9 _________________________ I54900MAY 30, 2024 8:16 TANK ANN TST NEEDED WRN: DISABLED ============================Request: 10 - I55300 - Line Re-Enable MethodRequest Source: Monitor System Configuration Requests - Line: 10 _________________________ I55300MAY 30, 2024 8:16 LINE RE-ENABLE METHODPASS LINE TEST file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ============================Request: 11 - I55600 - Line periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 11 _________________________ I55600MAY 30, 2024 8:16 LINE PER TST NEEDED WRN: DISABLED ============================Request: 12 - I55900 - Line Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 12 _________________________ I55900MAY 30, 2024 8:16 LINE ANN TST NEEDED WRN: DISABLED ============================Request: 13 - I50D00 - Print Temperature CompensationRequest Source: Monitor System Configuration Requests - Line: 13 _________________________ I50D00MAY 30, 2024 8:16 PRINT TC VOLUMESENABLED ============================Request: 14 - I50E00 - Temperature Compensation ValueRequest Source: Monitor System Configuration Requests - Line: 14 _________________________ I50E00MAY 30, 2024 8:16 TEMP COMPENSATIONVALUE (DEG F ): 60.0 ============================Request: 15 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 15 _________________________ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] I60B00MAY 30, 2024 8:16 STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 16 - I51400 - H-Protocol Height-Volume FormatRequest Source: Monitor System Configuration Requests - Line: 16 _________________________ I51400MAY 30, 2024 8:16 H-PROTOCOL DATA FORMATHEIGHT ============================Request: 17 - I51A01 - Auto Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 17 _________________________ I51A01MAY 30, 2024 8:16 DAYLIGHT SAVING TIMEENABLED ON ============================Request: 18 - I51B00 - Start-End Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 18 _________________________ I51B00MAY 30, 2024 8:16 DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM ============================Request: 19 - I51600 - Re-Direct Local PrintoutRequest Source: Monitor System Configuration Requests - Line: 19 _________________________ I51600MAY 30, 2024 8:16 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] RE-DIRECT LOCAL PRINTOUTDISABLED ============================Request: 20 - I50400 - RS-232 Security CodeRequest Source: Monitor System Configuration Requests - Line: 20 _________________________ I50400MAY 30, 2024 8:16 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED ============================Request: 21 - I21900 - Tank Chart SecurityRequest Source: Monitor System Configuration Requests - Line: 21 _________________________ I21900MAY 30, 2024 8:16 TANK CHART SECURITYDISABLED ============================Request: 22 - I5BD00 - Custom AlarmsRequest Source: Monitor System Configuration Requests - Line: 22 _________________________ I5BD00MAY 30, 2024 8:16 CUSTOM ALARM LABELS DISABLED ============================Request: 23 - I56000 - Mass Density Enable-Disable file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] Request Source: Monitor System Configuration Requests - Line: 23 _________________________ I56000MAY 30, 2024 8:16 MASS/DENSITY DISABLED ============================Request: 24 - I88101 - Comm Port 1 SettingsRequest Source: Monitor System Configuration Requests - Line: 24 _________________________ I88101MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 1 (EDIM )RS-232 SECURITYCODE : ****** ============================Request: 25 - I88102 - Comm Port 2 SettingsRequest Source: Monitor System Configuration Requests - Line: 25 _________________________ I88102MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : ****** DTR NORMAL STATE: HIGH ============================Request: 26 - I88103 - Comm Port 3 SettingsRequest Source: Monitor System Configuration Requests - Line: 26 _________________________ I88103MAY 30, 2024 8:16PORT SETTINGS: file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : ****** DTR NORMAL STATE: HIGH ============================Request: 27 - I88104 - Comm Port 4 SettingsRequest Source: Monitor System Configuration Requests - Line: 27 _________________________ I88104MAY 30, 2024 8:16 ============================Request: 28 - I88105 - Comm Port 5 SettingsRequest Source: Monitor System Configuration Requests - Line: 28 _________________________ I88105MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : ****** ============================Request: 29 - I88106 - Comm Port 6 SettingsRequest Source: Monitor System Configuration Requests - Line: 29 _________________________ I88106MAY 30, 2024 8:16PORT SETTINGS: COMM BOARD : 6 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : ****** file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ============================Request: 30 - I52000 - Receiver Auto Dial Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 30 _________________________ I52000MAY 30, 2024 8:16 RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAY 16, 2018 DISABLED 2 ON DATE MAY 16, 2018 DISABLED 3 ON DATE MAY 16, 2018 DISABLED 4 ON DATE MAY 16, 2018 DISABLED 5 ON DATE MAY 16, 2018 DISABLED 6 ON DATE MAY 16, 2018 DISABLED 7 ON DATE MAY 16, 2018 DISABLED 8 WEEKLY SAT 5:04 PM ============================Request: 31 - I60100 - Tank ConfigurationRequest Source: Monitor System Configuration Requests - Line: 31 _________________________ I60100MAY 30, 2024 8:16 TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 Unleaded 87A ON 2 Unleaded 87B ON 3 Premium ON 4 Gas Additive ON ============================Request: 32 - I60200 - Tank Product LabelRequest Source: Monitor System Configuration Requests - Line: 32 _________________________ I60200MAY 30, 2024 8:16 TANK PRODUCT LABEL TANK PRODUCT LABEL 1 Unleaded 87A 2 Unleaded 87B 3 Premium 4 Gas Additive file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ============================Request: 33 - I60300 - Tank Product CodeRequest Source: Monitor System Configuration Requests - Line: 33 _________________________ I60300MAY 30, 2024 8:16 TANK PRODUCT CODE TANK PRODUCT LABEL 1 Unleaded 87A 1 2 Unleaded 87B 1 3 Premium 2 4 Gas Additive 3 ============================Request: 34 - I60900 - Tank Thermal Expansion Coefficient Request Source: Monitor System Configuration Requests - Line: 34 _________________________ I60900MAY 30, 2024 8:16 TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 Unleaded 87A 0.000700 2 Unleaded 87B 0.000700 3 Premium 0.000700 4 Gas Additive 0.000405 ============================Request: 35 - I60700 - Tank DiameterRequest Source: Monitor System Configuration Requests - Line: 35 _________________________ I60700MAY 30, 2024 8:16 TANK DIAMETER TANK PRODUCT LABEL INCHES 1 Unleaded 87A 117.15 2 Unleaded 87B 114.49 3 Premium 116.37 4 Gas Additive 47.50 ============================Request: 36 - I60A00 - Tank Full VolumeRequest Source: Monitor System Configuration Requests - Line: 36 _________________________ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] I60A00MAY 30, 2024 8:16 TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 Unleaded 87A 20 PTS 30492 2 Unleaded 87B 20 PTS 29499 3 Premium 20 PTS 30169 4 Gas Additive 4 PTS 1514 ============================Request: 37 - I60400 - Tank 1 Point Full Volume HeightRequest Source: Monitor System Configuration Requests - Line: 37 _________________________ I60400MAY 30, 2024 8:16 TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30492 2 Unleaded 87B 29499 3 Premium 30169 4 Gas Additive 1514 ============================Request: 38 - I60500 - Tank 4 Point Full, 3/4, 1/2. 1/4 VolumesRequest Source: Monitor System Configuration Requests - Line: 38 _________________________ I60500MAY 30, 2024 8:16 TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30492 25161 15967 6578 2 Unleaded 87B 29499 23616 14600 5624 3 Premium 30169 24704 15583 6328 4 Gas Additive 1514 1220 762 299 ============================Request: 39 - I60600 - Tank 20 Point Full, 95%, 90%, ...volumesRequest Source: Monitor System Configuration Requests - Line: 39 _________________________ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] I60600MAY 30, 2024 8:16 TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30492 30208 29326 28136 26730 25161 23466 21675 19814 17904 15967 14023 12091 10191 8346 6578 4912 3381 2025 903 2 Unleaded 87B 29499 28886 27882 26629 25192 23616 21931 20165 18341 16479 14600 12722 10865 9048 7294 5624 4068 2657 1438 484 3 Premium 30169 29810 28892 27685 26273 24704 23016 21237 19390 17499 15583 13663 11756 9884 8067 6328 4693 3195 1874 792 4 Gas Additive 1514 0 0 0 0 1220 0 0 0 0 762 0 0 0 0 299 0 0 0 0 ============================Request: 40 - I61500 - BIR Meter Data PresentRequest Source: Monitor System Configuration Requests - Line: 40 _________________________ I61500MAY 30, 2024 8:16 TANK PRODUCT LABEL METER DATA 1 Unleaded 87A YES 2 Unleaded 87B YES 3 Premium YES 4 Gas Additive YES ============================Request: 41 - I62F00 - Mag Probe Float SizeRequest Source: Monitor System Configuration Requests - Line: 41 _________________________ I62F00MAY 30, 2024 8:16 MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 1 Unleaded 87A 4.0 IN. 2 Unleaded 87B 4.0 IN. 3 Premium 4.0 IN. 4 Gas Additive 4.0 IN. ============================Request: 42 - I62700 - Tank Height Water warning limitRequest Source: Monitor System Configuration Requests - Line: 42 _________________________ I62700MAY 30, 2024 8:17 TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 87A 0.8 2 Unleaded 87B 0.8 3 Premium 0.8 ============================Request: 43 - I64200 - Tank Water Filter LimitRequest Source: Monitor System Configuration Requests - Line: 43 _________________________ I64200MAY 30, 2024 8:17 WATER ALARM FILTER TANK PRODUCT LABEL 1 Unleaded 87A LOW 2 Unleaded 87B LOW 3 Premium LOW ============================Request: 44 - I62400 - Tank High Water Level LimitRequest Source: Monitor System Configuration Requests - Line: 44 _________________________ I62400MAY 30, 2024 8:17 TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 87A 2.0 2 Unleaded 87B 2.0 3 Premium 2.0 ============================Request: 45 - I62800 - Tank Maximum Volume Limit file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] Request Source: Monitor System Configuration Requests - Line: 45 _________________________ I62800MAY 30, 2024 8:17 TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 30493 2 Unleaded 87B 29500 3 Premium 30170 4 Gas Additive 1514 ============================Request: 46 - I62300 - Tank Overfill Level limitRequest Source: Monitor System Configuration Requests - Line: 46 _________________________ I62300MAY 30, 2024 8:17 TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 27443 2 Unleaded 87B 26550 3 Premium 27153 4 Gas Additive 1363 ============================Request: 47 - I62200 - Tank High Level LimitRequest Source: Monitor System Configuration Requests - Line: 47 _________________________ I62200MAY 30, 2024 8:17 TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 28663 2 Unleaded 87B 27730 3 Premium 28360 4 Gas Additive 1438 ============================Request: 48 - I62900 - Tank Delivery Required limitRequest Source: Monitor System Configuration Requests - Line: 48 _________________________ I62900MAY 30, 2024 8:17 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 6099 2 Unleaded 87B 5900 3 Premium 6034 4 Gas Additive 150 ============================Request: 49 - I62100 - Tank Low Level LimitRequest Source: Monitor System Configuration Requests - Line: 49 _________________________ I62100MAY 30, 2024 8:17 TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 915 2 Unleaded 87B 885 3 Premium 905 4 Gas Additive 114 ============================Request: 50 - I62600 - Tank Leak Alarm LimitRequest Source: Monitor System Configuration Requests - Line: 50 _________________________ I62600MAY 30, 2024 8:17 TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 8 2 Unleaded 87B 8 3 Premium 8 4 Gas Additive 8 ============================Request: 51 - I62500 - Tank Sudden Loss LimitRequest Source: Monitor System Configuration Requests - Line: 51 _________________________ I62500MAY 30, 2024 8:17 TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 99 2 Unleaded 87B 99 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 3 Premium 99 4 Gas Additive 99 ============================Request: 52 - I60800 - Tank TiltRequest Source: Monitor System Configuration Requests - Line: 52 _________________________ I60800MAY 30, 2024 8:17 TANK TILT TANK PRODUCT LABEL INCHES 1 Unleaded 87A 0.00 2 Unleaded 87B 0.00 3 Premium 0.00 4 Gas Additive 0.00 ============================Request: 53 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 53 _________________________ I60B00MAY 30, 2024 8:17 STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 54 - I60C00 - Tank Stick Height offsetRequest Source: Monitor System Configuration Requests - Line: 54 _________________________ I60C00MAY 30, 2024 8:17 TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 Unleaded 87A 0.00 2 Unleaded 87B 0.00 3 Premium 0.00 4 Gas Additive 0.00 ============================Request: 55 - I61200 - Tank Siphon Manifold partnersRequest Source: Monitor System Configuration Requests - Line: 55 _________________________ I61200MAY 30, 2024 8:17 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 Unleaded 87A 2 NONE 2 Unleaded 87B 1 NONE 3 Premium NONE NONE 4 Gas Additive NONE NONE ============================Request: 56 - I63600 - Tank Periodic Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 56 _________________________ I63600MAY 30, 2024 8:17 PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 24050 2 Unleaded 87B 24050 3 Premium 24050 4 Gas Additive 0 ============================Request: 57 - I62A00 - Tank Annual Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 57 _________________________ I62A00MAY 30, 2024 8:17 ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 24050 2 Unleaded 87B 24050 3 Premium 24050 4 Gas Additive 0 ============================Request: 58 - I62C00 - Tank Periodic Test TypeRequest Source: Monitor System Configuration Requests - Line: 58 _________________________ I62C00MAY 30, 2024 8:17 TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 Unleaded 87A STANDARD 2 Unleaded 87B STANDARD file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 3 Premium STANDARD 4 Gas Additive STANDARD ============================Request: 59 - I62D00 - Enable-Disable Tank Test Leak Fail AlarmsRequest Source: Monitor System Configuration Requests - Line: 59 _________________________ I62D00MAY 30, 2024 8:17 TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 Unleaded 87A GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 Unleaded 87B GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 Premium GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 Gas Additive GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ============================Request: 60 - I63100 - Tank Leak Test AveragingRequest Source: Monitor System Configuration Requests - Line: 60 _________________________ I63100MAY 30, 2024 8:17 TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 Unleaded 87A OFF OFF 2 Unleaded 87B OFF OFF 3 Premium OFF OFF 4 Gas Additive OFF OFF ============================Request: 61 - I63000 - Tank Leak Test notifyRequest Source: Monitor System Configuration Requests - Line: 61 _________________________ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] I63000MAY 30, 2024 8:17 IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 Unleaded 87A OFF 2 Unleaded 87B OFF 3 Premium OFF 4 Gas Additive OFF ============================Request: 62 - I63200 - Tank Test Siphon BreakRequest Source: Monitor System Configuration Requests - Line: 62 _________________________ I63200MAY 30, 2024 8:17 TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 Unleaded 87A OFF 2 Unleaded 87B OFF 3 Premium OFF 4 Gas Additive OFF ============================Request: 63 - I61000 - Tank delivery DelayRequest Source: Monitor System Configuration Requests - Line: 63 _________________________ I61000MAY 30, 2024 8:17 TANK DELIVERY DELAY TANK PRODUCT LABEL 1 Unleaded 87A 1 2 Unleaded 87B 1 3 Premium 1 4 Gas Additive 1 ============================Request: 64 - I63A00 - Tank low Level Threshold for Line Manifold Request Source: Monitor System Configuration Requests - Line: 64 _________________________ I63A00MAY 30, 2024 8:17 LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] TANK PRODUCT LABEL PUMP THRESHOLD 1 Unleaded 87A 10.00% 2 Unleaded 87B 10.00% 3 Premium 10.00% 4 Gas Additive 10.00% ============================Request: 65 - I61100 - Tank Leak Test Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 65 _________________________ I61100MAY 30, 2024 8:17 LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKJUN 7, 2013START TIME : DISABLEDTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED ============================Request: 66 - I61300 - CSLD Probability of DetectionRequest Source: Monitor System Configuration Requests - Line: 66 _________________________ I61300MAY 30, 2024 8:17CSLD PROBABLITY OF DETECTION ============================Request: 67 - I61400 - CSLD Climate FactorRequest Source: Monitor System Configuration Requests - Line: 67 _________________________ I61400MAY 30, 2024 8:17CSLD CLIMATE FACTOR ============================Request: 68 - I61600 - Accuchart Update SchedulingRequest Source: Monitor System Configuration Requests - Line: 68 _________________________ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] I61600MAY 30, 2024 8:17 TANK PRODUCT LABEL CAL UPDATE 1 Unleaded 87A NEVER 2 Unleaded 87B NEVER 3 Premium NEVER 4 Gas Additive NEVER ============================Request: 69 - I61A00 - In-Tank Leak Test Early StopRequest Source: Monitor System Configuration Requests - Line: 69 _________________________ I61A00MAY 30, 2024 8:17 IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 Unleaded 87A DISABLED 2 Unleaded 87B DISABLED 3 Premium DISABLED 4 Gas Additive DISABLED ============================Request: 70 - I61B00 - In-Tank Static Gross Test Auto-ConfirmRequest Source: Monitor System Configuration Requests - Line: 70 _________________________ I61B00MAY 30, 2024 8:17 IN-TANK LEAK GROSS TEST AUTO-CONFIRM ============================Request: 71 - I61C00 - CSLD Report Only modeRequest Source: Monitor System Configuration Requests - Line: 71 _________________________ I61C00MAY 30, 2024 8:17 CSLD REPORT ONLY ============================Request: 72 - I62B00 - Tank Last Annual TestRequest Source: Monitor System Configuration Requests - Line: 72 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] _________________________ I62B00MAY 30, 2024 8:17 TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 Unleaded 87A ??? 0, 0 2 Unleaded 87B ??? 0, 0 3 Premium ??? 0, 0 4 Gas Additive ??? 0, 0 ============================Request: 73 - I63300 - Leak Test Report TypeRequest Source: Monitor System Configuration Requests - Line: 73 _________________________ I63300MAY 30, 2024 8:17 LEAK TEST REPORT FORMAT: NORMAL ============================Request: 74 - I63400 - Tank HRM Reconciliation Warning limitRequest Source: Monitor System Configuration Requests - Line: 74 _________________________ I63400MAY 30, 2024 8:17 RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 0 2 Unleaded 87B 0 3 Premium 0 4 Gas Additive 0 ============================Request: 75 - I63500 - Tank HEM Reconciliation AlarmRequest Source: Monitor System Configuration Requests - Line: 75 _________________________ I63500MAY 30, 2024 8:17 RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 87A 1 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 2 Unleaded 87B 1 3 Premium 1 4 Gas Additive 1 ============================Request: 76 - I63900 - Tank Accuchart End Shape Type and FactorRequest Source: Monitor System Configuration Requests - Line: 76 _________________________ I63900MAY 30, 2024 8:17 ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 Unleaded 87A END FACTOR: OTHEREND VALUE: 1.0 2 Unleaded 87B END FACTOR: OTHEREND VALUE: 1.0 3 Premium END FACTOR: OTHEREND VALUE: 1.0 4 Gas Additive END FACTOR: HEMISPHER ============================Request: 77 - I78000 - PLLD SetupRequest Source: Monitor System Configuration Requests - Line: 77 _________________________ I78000MAY 30, 2024 8:17 PRESSURE LINE LEAK SETUP Q 1:UNLEADED 87A TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 310 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 1:Unleaded 87A file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] DISPENSE MODE:STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:UNLEADED 87B TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 320 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 2:Unleaded 87B DISPENSE MODE:STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:PREMIUM TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 330 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 3:Premium DISPENSE MODE:STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO ============================Request: 78 - I77700 - PLLD Primary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 78 _________________________ I77700MAY 30, 2024 8:17 ============================ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] Request: 79 - I77800 - PLLD Secondary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 79 _________________________ I77800MAY 30, 2024 8:17 ============================Request: 80 - I78C00 - PLLD 0.20 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 80 _________________________ I78C00MAY 30, 2024 8:17 PRESSURE LINE LEAK 0.20 TEST SCHEDULE LINE 0.20 GPH TESTQ 1:UNLEADED 87A REPETITIVQ 2:UNLEADED 87B REPETITIVQ 3:PREMIUM REPETITIV ============================Request: 81 - I78300 - PLLD 0.10 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 81 _________________________ I78300MAY 30, 2024 8:17 PRESSURE LINE LEAK 0.10 TEST SCHEDULE LINE 0.10 GPH TESTQ 1:UNLEADED 87A AUTOQ 2:UNLEADED 87B AUTOQ 3:PREMIUM AUTO ============================Request: 82 - I78F00 - PLLD Dispense ThresholdRequest Source: Monitor System Configuration Requests - Line: 82 _________________________ I78F00MAY 30, 2024 8:17 PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSUREQ 1:UNLEADED 87A 5 PSIQ 2:UNLEADED 87B 5 PSI file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] Q 3:PREMIUM 5 PSI ============================Request: 83 - I78700 - PLLD Disable Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 83 _________________________ I78700MAY 30, 2024 8:17 PRESSURE LLD SETUP REPORT Q 1:UNLEADED 87A IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L 1:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] L18:SHORT ALARM L19:SHORT ALARM L 1:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L 1:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L18:LOW LIQUID ALARM L19:LOW LIQUID ALARM L 1:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L19:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 1:SETUP DATA WARNING s 3:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 1:COMMUNICATION ALARM s 3:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 1:SENSOR FAULT ALARM s 3:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 1:HIGH LIQUID WARNING s 3:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 1:HIGH LIQUID ALARM s 2:HIGH LIQUID ALARM s 3:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM s11:LOW LIQUID WARNING s13:LOW LIQUID WARNING s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 1:SENSOR FAULT WARN s 3:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 1:VACUUM WARNING s 3:VACUUM WARNING s 1:NO VACUUM ALARM s 2:NO VACUUM ALARM s 3:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL Q 2:UNLEADED 87B IN-TANK ALARMS T 1:HIGH WATER ALARM file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L19:SHORT ALARM L21:SHORT ALARM L 2:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L 2:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L19:LOW LIQUID ALARM L21:LOW LIQUID ALARM L 2:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L19:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 4:SETUP DATA WARNING s 5:SETUP DATA WARNING s 6:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 4:COMMUNICATION ALARM s 5:COMMUNICATION ALARM s 6:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 4:SENSOR FAULT ALARM s 5:SENSOR FAULT ALARM s 6:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 4:HIGH LIQUID WARNING s 5:HIGH LIQUID WARNING s 6:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 4:HIGH LIQUID ALARM s 5:HIGH LIQUID ALARM s 6:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] s13:HIGH LIQUID ALARM s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 4:SENSOR FAULT WARN s 5:SENSOR FAULT WARN s 6:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 4:VACUUM WARNING s 5:VACUUM WARNING s 6:VACUUM WARNING s13:VACUUM WARNING s 4:NO VACUUM ALARM s 5:NO VACUUM ALARM s 6:NO VACUUM ALARM s13:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL Q 3:PREMIUM IN-TANK ALARMS T 3:HIGH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] L22:FUEL ALARM L23:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 3:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L 3:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 3:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L22:LIQUID WARNING PRESSURE LINE LEAK file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 9:SETUP DATA WARNING s10:SETUP DATA WARNING s15:SETUP DATA WARNING s 9:COMMUNICATION ALARM s10:COMMUNICATION ALARM s15:COMMUNICATION ALARM s 9:SENSOR FAULT ALARM s10:SENSOR FAULT ALARM s15:SENSOR FAULT ALARM s15:FUEL WARNING s15:FUEL ALARM s15:WATER WARNING s15:WATER ALARM s 9:HIGH LIQUID WARNING s10:HIGH LIQUID WARNING s15:HIGH LIQUID WARNING s 9:HIGH LIQUID ALARM s10:HIGH LIQUID ALARM s15:HIGH LIQUID ALARM s15:LOW LIQUID ALARM s15:INSTALL ALARM s 9:SENSOR FAULT WARN s10:SENSOR FAULT WARN s15:SENSOR FAULT WARN s 9:VACUUM WARNING s10:VACUUM WARNING s 9:NO VACUUM ALARM s10:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ============================Request: 84 - I70200 - Liquid Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 84 _________________________ I70200MAY 30, 2024 8:18 LIQUID LABEL DEVICE LABEL 1 UNLEADED 87A ANNULAR 2 UNLEADED 87B ANNULAR 3 PREMIUM ANNULAR 4 ADDITIVE ANNULAR 5 ADDITIVE SUMP 6 ADDITIVE VENT BOX 7 8 9 DISP PAN 1-2 10 DISP PAN 3-4 11 DISP PAN 5-6 12 DISP PAN 7-8 13 DISP PAN 9-10 14 DISP PAN 11-12 15 DISP PAN 13-14 16 DISP PAN 15-16 17 UNL 87A STP BRINE 18 UNL 87A FILL 19 UNL 87B STP BRINE 20 21 UNL 87B FILL 22 91 STP BRINE 23 91 FILL 24 PERMEATOR ============================Request: 85 - I70300 - Liquid Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 85 _________________________ I70300MAY 30, 2024 8:18 LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED 87A ANNULAR DUAL POINT HYDROSTATIC 2 UNLEADED 87B ANNULAR DUAL POINT HYDROSTATIC 3 PREMIUM ANNULAR DUAL POINT HYDROSTATIC 4 ADDITIVE ANNULAR DUAL POINT HYDROSTATIC 5 ADDITIVE SUMP DW SUMP 2-1 6 ADDITIVE VENT BOX DW SUMP 2-1 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP PAN 1-2 DW SUMP 2-1 10 DISP PAN 3-4 DW SUMP 2-1 11 DISP PAN 5-6 DW SUMP 2-1 12 DISP PAN 7-8 DW SUMP 2-1 13 DISP PAN 9-10 DW SUMP 2-1 14 DISP PAN 11-12 DW SUMP 2-1 15 DISP PAN 13-14 DW SUMP 2-1 16 DISP PAN 15-16 DW SUMP 2-1 17 UNL 87A STP BRINE TRI-STATE (SINGLE FLOAT) 18 UNL 87A FILL DW SUMP 2-1 19 UNL 87B STP BRINE TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 UNL 87B FILL DW SUMP 2-1 22 91 STP BRINE TRI-STATE (SINGLE FLOAT) 23 91 FILL DW SUMP 2-1 24 PERMEATOR NORMALLY CLOSED ============================Request: 86 - I70400 - Liquid Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 86 _________________________ I70400MAY 30, 2024 8:18 LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED 87A ANNULAR ANNULAR SPACE 2 UNLEADED 87B ANNULAR ANNULAR SPACE 3 PREMIUM ANNULAR ANNULAR SPACE 4 ADDITIVE ANNULAR ANNULAR SPACE 5 ADDITIVE SUMP STP SUMP 6 ADDITIVE VENT BOX DISPENSER PAN 7 OTHER SENSORS 8 OTHER SENSORS 9 DISP PAN 1-2 DISPENSER PAN 10 DISP PAN 3-4 DISPENSER PAN 11 DISP PAN 5-6 DISPENSER PAN 12 DISP PAN 7-8 DISPENSER PAN 13 DISP PAN 9-10 DISPENSER PAN 14 DISP PAN 11-12 DISPENSER PAN 15 DISP PAN 13-14 DISPENSER PAN 16 DISP PAN 15-16 DISPENSER PAN 17 UNL 87A STP BRINE ANNULAR SPACE 18 UNL 87A FILL OTHER SENSORS 19 UNL 87B STP BRINE ANNULAR SPACE 20 OTHER SENSORS 21 UNL 87B FILL OTHER SENSORS 22 91 STP BRINE ANNULAR SPACE 23 91 FILL ANNULAR SPACE 24 PERMEATOR OTHER SENSORS file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ============================Request: 87 - I74200 - Type "A" 2 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 87 _________________________ I74200MAY 30, 2024 8:18 ============================Request: 88 - I74300 - Type "A" 2 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 88 _________________________ I74300MAY 30, 2024 8:18 ============================Request: 89 - I74400 - Type "A" 2 Wire Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 89 _________________________ I74400MAY 30, 2024 8:18 ============================Request: 90 - I74700 - Type "B" 3 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 90 _________________________ I74700MAY 30, 2024 8:18 ============================Request: 91 - I74800 - Type "B" 3 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 91 _________________________ I74800MAY 30, 2024 8:18 ============================Request: 92 - I74900 - Type "B" Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 92 _________________________ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] I74900MAY 30, 2024 8:18 ============================Request: 93 - I7BC00 - I/O Device Line Disable AssignmentsRequest Source: Monitor System Configuration Requests - Line: 93 _________________________ I7BC00MAY 30, 2024 8:18 ============================Request: 94 - I80200 - I/O Input location LabelRequest Source: Monitor System Configuration Requests - Line: 94 _________________________ I80200MAY 30, 2024 8:18 EXTERNAL INPUT LABEL DEVICE LABEL 1 ARID FAULT 2 ARID ACTIVE ============================Request: 95 - I80300 - I/O Input TypeRequest Source: Monitor System Configuration Requests - Line: 95 _________________________ I80300MAY 30, 2024 8:18 EXTERNAL INPUT TYPE INPUT NAME TYPE ORIENTATION TANK# 1 ARID FAULT VP PROCESSOR NORMALLY CLOSED 2 ARID ACTIVE VP PROCESSR2 NORMALLY OPEN ============================Request: 96 - I80400 - I/O Input Dispense modeRequest Source: Monitor System Configuration Requests - Line: 96 _________________________ I80400MAY 30, 2024 8:18 ============================ file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] Request: 97 - I80700 - I/O Relay location labelRequest Source: Monitor System Configuration Requests - Line: 97 _________________________ I80700MAY 30, 2024 8:18 RELAY LABEL DEVICE LABEL 1 OUTSIDE OVERFILL 2 WAREHOUSE V-R ALARM 3 ADDITIVE SHUTDOWN 4 5 6 ============================Request: 98 - I80900 - I/O Relay OrientationRequest Source: Monitor System Configuration Requests - Line: 98 _________________________ I80900MAY 30, 2024 8:18 RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 OUTSIDE OVERFILL NORMALLY OPEN 2 WAREHOUSE V-R ALARM NORMALLY OPEN 3 ADDITIVE SHUTDOWN NORMALLY OPEN 4 NORMALLY OPEN 5 NORMALLY OPEN 6 NORMALLY OPEN ============================Request: 99 - I80B00 - I/O Relay Tank AssignmentRequest Source: Monitor System Configuration Requests - Line: 99 _________________________ I80B00MAY 30, 2024 8:18 RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 OUTSIDE OVERFILL NONE 2 WAREHOUSE V-R ALARM NONE 3 ADDITIVE SHUTDOWN 4 4 NONE 5 NONE 6 NONE file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ============================Request: 100 - I80A00 - I/O Relay TypeRequest Source: Monitor System Configuration Requests - Line: 100 _________________________ I80A00MAY 30, 2024 8:18 RELAY TYPE RELAY DESIGNATION TYPE 1 OUTSIDE OVERFILL STANDARD 2 WAREHOUSE V-R ALARM STANDARD 3 ADDITIVE SHUTDOWN PUMP CONTROL OUTPUT 4 STANDARD 5 STANDARD 6 STANDARD ============================Request: 101 - I80C00 - I/O External input TypeRequest Source: Monitor System Configuration Requests - Line: 101 _________________________ I80C00MAY 30, 2024 8:18 EXTERNAL INPUT TYPE INPUT NAME TYPE ORIENTATION TANK# 1 ARID FAULT VP PROCESSOR NORMALLY CLOSED 2 ARID ACTIVE VP PROCESSR2 NORMALLY OPEN ============================Request: 102 - I80800 - I/O Relay Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 102 _________________________ I80800MAY 30, 2024 8:18 RELAY SETUP REPORT R 1:OUTSIDE OVERFILL TYPE: STANDARDNORMALLY OPEN TANK #: NONE file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 2:WAREHOUSE V-R ALARM TYPE: STANDARDNORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ALL:LOW LIQUID ALARM ALL:TEMPERATURE WARNING ALL:RELAY ACTIVE ALL:INSTALL ALARM ALL:SENSOR FAULT WARN ALL:VACUUM WARNING ALL:NO VACUUM ALARM ALL:BATTERY WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 3:ADDITIVE SHUTDOWN TYPE: PUMP CONTROL OUTPUTTANK #: 4 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] IN-TANK ALARMS T 4:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 4:HIGH LIQUID ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L 4:LOW LIQUID ALARM L 5:LOW LIQUID ALARM L 6:LOW LIQUID ALARM L 4:LIQUID WARNING L 5:LIQUID WARNING L 6:LIQUID WARNING SMARTSENSOR ALARMS s12:COMMUNICATION ALARM s12:SENSOR FAULT ALARM s12:HIGH LIQUID WARNING s12:HIGH LIQUID ALARM s12:SENSOR FAULT WARN s12:VACUUM WARNING s12:NO VACUUM ALARM R 4: TYPE: STANDARDNORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5: TYPE: STANDARDNORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 6: TYPE: STANDARDNORMALLY OPEN TANK #: NONE file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] - NO ALARM ASSIGNMENTS - ============================Request: 103 - I79000 - DIM Software RevisionRequest Source: Monitor System Configuration Requests - Line: 103 _________________________ I79000MAY 30, 2024 8:19 EDIM:1 VR:349806-002-A 5 TD:16.12.14.16.18 ============================Request: 104 - I79100 - Mechanical Dispenser Interface StringRequest Source: Monitor System Configuration Requests - Line: 104 _________________________ I79100MAY 30, 2024 8:19 ============================Request: 105 - I72300 - Smart Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 105 _________________________ I72300MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 UNL 87A PRODUCT LINE VAC SENSOR02 VAPOR LINE VAC SENSOR03 UNL 87A VENT LINE VAC SENSOR04 UNL 87B PRODUCT LINE VAC SENSOR05 UNL 87B SIPHON LINE VAC SENSOR06 UNL 87B VENT LINE VAC SENSOR07 PRESSURE SENSOR 3-4 VAPOR PRESSURE08 ATP ATM P SENSOR09 PREMIUM PRODUCT LINE VAC SENSOR10 PREMIUM VENT LINE VAC SENSOR11 87A STP SUMP MAG SENSOR12 ADDITIVE PRODUCT VAC VAC SENSOR file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 13 87B STP SUMP MAG SENSOR14 ADDITIVE VENT VAC VAC SENSOR15 PREMIUM STP SUMP MAG SENSOR16 UNKNOWN17 DISP 1-2 AIR FLOW METER18 DISP 3-4 AIR FLOW METER19 DISP 5-6 AIR FLOW METER20 DISP 7-8 AIR FLOW METER21 DISP 9-10 AIR FLOW METER22 DISP 11-12 AIR FLOW METER23 DISP 13-14 AIR FLOW METER24 DISP 15-16 AIR FLOW METER25 UNKNOWN26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN38 UNKNOWN39 UNKNOWN40 UNKNOWN ============================Request: 106 - IV4E00 - ISD EVR TypeRequest Source: Monitor System Configuration Requests - Line: 106 _________________________ IV4E00MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC ============================Request: 107 - IV4F00 - ISD Nozzle TypeRequest Source: Monitor System Configuration Requests - Line: 107 _________________________ IV4F00MAY 30, 2024 8:19 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 ============================Request: 108 - IV4000 - Vapor Processor TypeRequest Source: Monitor System Configuration Requests - Line: 108 _________________________ IV4000MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA VAPOR PROCESSOR TYPEARID PERMEATOR ============================Request: 109 - IV4700 - ISD Assessment Start and Post DelayRequest Source: Monitor System Configuration Requests - Line: 109 _________________________ IV4700MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA ASSESSMENT TIMESTART TIME: 05:00TIME DELAY MINUTES: 1 ============================Request: 110 - IV5200 - High ORVR ConfigurationRequest Source: Monitor System Configuration Requests - Line: 110 _________________________ IV5200MAY 30, 2024 8:19 279395 COSTCO #643 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] 4900 Panama Lane Bakersfield, CA ACCEPT HIGH ORVR: YES ============================Request: 111 - IV4A00 - ISD Hose TableRequest Source: Monitor System Configuration Requests - Line: 111 _________________________ IV4A00MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND2 02 02 02 01 UU BLEND2 03 03 03 02 UU BLEND2 04 04 04 02 UU BLEND2 05 05 05 03 UU BLEND2 06 06 06 03 UU BLEND2 07 07 07 04 UU BLEND2 08 08 08 04 UU BLEND2 09 09 09 05 UU BLEND2 10 10 10 05 UU BLEND2 11 11 11 06 UU BLEND2 12 12 12 06 UU BLEND2 13 13 13 07 UU BLEND2 14 14 14 07 UU BLEND2 15 15 15 08 UU BLEND2 16 16 16 08 UU BLEND2 ============================Request: 112 - IV4B00 - ISD Grade TableRequest Source: Monitor System Configuration Requests - Line: 112 _________________________ IV4B00MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA PRODUCT/HOSE MAP TABLE file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 00/01 01/01 xx/xx xx/xx02 01 00/02 01/02 xx/xx xx/xx03 02 00/03 01/03 xx/xx xx/xx04 02 00/04 01/04 xx/xx xx/xx05 03 00/05 01/05 xx/xx xx/xx06 03 00/06 01/06 xx/xx xx/xx07 04 00/07 01/07 xx/xx xx/xx08 04 00/08 01/08 xx/xx xx/xx09 05 00/09 01/09 xx/xx xx/xx10 05 00/10 01/10 xx/xx xx/xx11 06 00/11 01/11 xx/xx xx/xx12 06 00/12 01/12 xx/xx xx/xx13 07 00/13 01/13 xx/xx xx/xx14 07 00/14 01/14 xx/xx xx/xx15 08 00/15 01/15 xx/xx xx/xx16 08 00/16 01/16 xx/xx xx/xx ============================Request: 113 - IV4900 - ISD Hose Label TableRequest Source: Monitor System Configuration Requests - Line: 113 _________________________ IV4900MAY 30, 2024 8:19 279395 COSTCO #643 4900 Panama Lane Bakersfield, CA LABEL TABLEID LABEL01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 ============================Request: 114 - IV1000 - ISD VersionRequest Source: Monitor System Configuration Requests - Line: 114 _________________________ IV1000MAY 30, 2024 8:19 file:///C/...rmation/Costco%20Monitor%20Certs/Monitor%20Certs.%202024/%23643%20Bakersfield/643%20Bakersfield%20VR-Setup.txt[5/30/2024 10:38:20 AM] ISD VERSION: 01.07 End of Report: 240530 +============================================================================| Monitoring System Report Saved at: Thursday, May 30, 2024 - 8:27:27 AM| (Report Saved Date/Time from PC Clock)| Using Monitoring System Report Utility by FASTECH || Version: Version 6.0.0.100 |+============================================================================ Facility Name: Date of Testing:5/30/2024 Facility Address:Bakersfield 93313 Phone: 661-834-2026 Company Name:Phone:(951) 906-3023 Technician Conducting Test:Bill Karras Credentials: CSLB Contractor License Number(s):888712 Test Equipment Used: VMI LDT-890 3gph@10psi Electronic Electronic Electronic Mechanical Leak Detector Make / Model V/R PLLD V/R PLLD V/R PLLD F.E. Petro Serial Number 241103 247502 236659 13040390 Submersible Pump Manufacturer F.E. Petro F.E Petro F.E Petro F.E. Petro Leak Rate Tested 3.0 Gph 3.0 Gph 3.0 Gph 3.0 Gph Check Valve PSI 19 18 19 17 Metering PSI 40 38 38 30 Technician's Signature:Date: 5/30/2024 Electronic LLD Shut off submersible pump. Mechanical LLD Restricts the flow. Pass / Fail Threshold or Criteria Electronic LLD Shut off sumbmersible pump. Electronic LLD Shut off sumbmersible pump. Pass Pass Pass Pass Comments: (Include information on repairs made prior to testing and recommended follow-up for failed tests) Test Results: CERTIFICATION OF TECHNICIAN RESPONAIBLE FOR CONDUCTING THIS TESTING Bill Karras Line Leak Detector Type: W.S.K. & Sons Inc. 4900 Panama LaneCostco Wholesale #643 Equipment calibrated leak rate: 87B Additive91A87A 3. LINE LEAK DETECTOR TESTING INFORMATION Line Leak Detector Label Line Leak Detector Testing Report Form 1. FACILITY INFORMATION 2. TESTING CONTRACTOR INFORMATION Emergency Stop Switch Operation Inspection Facility: Costco Wholesale #643 Date: 5/30/2024 Address: 4900 Panama Lane Testing Company: W.S.K. & Sons Inc City, State, Zip: Bakersfield, CA 93313 Tester Name: Bill Karras This procedure is to verify the operation of all emergency stop switches/buttons (E-stops). Each E-Stop must disconnect power to the dispensers, submersible turbine pumps (STPs) and all non-intrinsically safe electrical equipment in classified areas. Test each E-Stop separately. See PEI/RP1200, Section 11 for the inspection procedure. E-Stop Number or ID 1 2 3 Location Inside Data Hut Outside on Data Hut South Planter 1. E-stop labeled and located where easily accessible? X Yes No X Yes No X Yes No 2. System is fully powered and in normal operating condition? X Yes No X Yes No X Yes No 3. After activating E-stop, power has been disconnected from: 3a. All dispensing devices on all islands? X Yes No X Yes No X Yes No 3b. All STPs for all fuel grades? X Yes No X Yes No X Yes No 3c. All power, control and signal circuits associated with the dispensing devices and the STPs? X Yes No X Yes No X Yes No 3d. All other non-Intrinsically safe electrical equipment in classified areas surrounding fuel dispensing devices? X Yes No X Yes No X Yes No 4. All intrinsically safe electrical equipment remains energized after E-stop activation? X Yes No X Yes No X Yes No 5. After testing, has E-stop been reset and power reestablished to normal operating condition? X Yes No X Yes No X Yes No A "No" to lines 3a-3d indicate a test failure. Test Results: X Pass Fail X Pass Fail X Pass Fail Comments: Tester's Signature Bill Karras Date: 5/30/2024 Revised 11/03/2014 UST System Impact Valve Testing Location Name: Costco Wholesale #643 Date: 5/30/2024 Address: 4900 Panama Ln. City:Bakersfield State: CA Dispenser Number Product Grade Impact Valve Secure? Impact Valve Locks? Test Result Comments 1 / 2 All Yes Yes Pass 3 /4 All Yes Yes Pass 5/6 All Yes Yes Pass 7/8 All Yes Yes Pass 9/10 All Yes Yes Pass 11/12 All Yes Yes Pass 13/14 All Yes Yes Pass 15/16 All Yes Yes Pass Revised 10/22/2014 UST Sump Extinguisher Verification Location Name: Costco Wholesale #643 Date: 5/30/2024 Address: 4900 Panama Ln City: Bakersfield State: CA Extinguisher is in place and Secure? Extinguisher arrow is in the Green? Comments Tank Sumps 87 A Turbine Sump Yes Yes 87 A Fill Sump Yes Yes 87 B Turbine Sump Yes Yes 87 B Fill Sump Yes Yes 91 Turbine Sump Yes Yes 91 Fill Sump Yes Yes Additive Tank Sump Yes Yes Diesel Sumps Yes Yes Other Tank Sump: Other Tank Sump: Under Dispenser Containment Sumps Dispenser 1/2 Yes Yes Dispenser 3/4 Yes Yes Dispenser 5/6 Yes Yes Dispenser 7/8 Yes Yes Dispenser 9/10 Yes Yes Dispenser 11/12 Yes Yes Dispenser 13/14 Yes Yes Dispenser 15/16 Yes Yes Dispenser 17/18 Dispenser 19/20 Dispenser 21/22 Dispenser 23/24 Other Miscellaneous Containment Sumps Vent Box Yes Yes Additive Sump: Yes Yes Other Sump: Other Sump: (4') DWT-6 TYPE II 1,500 GALLON DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 1/8 2 6 1/8 117 12 1/8 306 18 1/8 533 24 1/8 775 30 1/8 1016 1/4 3 6 1/4 120 12 1/4 311 18 1/4 537 24 1/4 780 30 1/4 1021 3/8 4 6 3/8 124 12 3/8 315 18 3/8 542 24 3/8 785 30 3/8 1026 1/2 5 6 1/2 127 12 1/2 320 18 1/2 547 24 1/2 790 30 1/2 1031 5/8 7 6 5/8 131 12 5/8 324 18 5/8 552 24 5/8 795 30 5/8 1036 3/4 8 6 3/4 134 12 3/4 329 18 3/4 557 24 3/4 800 30 3/4 1040 7/8 9 6 7/8 138 12 7/8 333 18 7/8 562 24 7/8 805 30 7/8 1045 1 11 7 141 13 338 19 567 25 811 31 1050 1 1/8 12 7 1/8 145 13 1/8 342 19 1/8 572 25 1/8 816 31 1/8 1055 1 1/4 14 7 1/4 149 13 1/4 347 19 1/4 577 25 1/4 821 31 1/4 1060 1 3/8 16 7 3/8 152 13 3/8 351 19 3/8 582 25 3/8 826 31 3/8 1065 1 1/2 18 7 1/2 156 13 1/2 356 19 1/2 587 25 1/2 831 31 1/2 1069 1 5/8 19 7 5/8 159 13 5/8 360 19 5/8 592 25 5/8 836 31 5/8 1074 1 3/4 21 7 3/4 163 13 3/4 365 19 3/4 597 25 3/4 841 31 3/4 1079 1 7/8 23 7 7/8 167 13 7/8 370 19 7/8 602 25 7/8 846 31 7/8 1084 2 25 8 171 14 374 20 607 26 851 32 1088 2 1/8 27 8 1/8 174 14 1/8 379 20 1/8 612 26 1/8 856 32 1/8 1093 2 1/4 30 8 1/4 178 14 1/4 383 20 1/4 617 26 1/4 861 32 1/4 1098 2 3/8 32 8 3/8 182 14 3/8 388 20 3/8 622 26 3/8 866 32 3/8 1103 2 1/2 34 8 1/2 186 14 1/2 393 20 1/2 628 26 1/2 871 32 1/2 1107 2 5/8 36 8 5/8 190 14 5/8 397 20 5/8 633 26 5/8 877 32 5/8 1112 2 3/4 39 8 3/4 194 14 3/4 402 20 3/4 638 26 3/4 882 32 3/4 1117 2 7/8 41 8 7/8 198 14 7/8 407 20 7/8 643 26 7/8 887 32 7/8 1121 3 44 9 202 15 412 21 648 27 892 33 1126 3 1/8 46 9 1/8 205 15 1/8 416 21 1/8 653 27 1/8 897 33 1/8 1131 3 1/4 49 9 1/4 209 15 1/4 421 21 1/4 658 27 1/4 902 33 1/4 1135 3 3/8 51 9 3/8 213 15 3/8 426 21 3/8 663 27 3/8 907 33 3/8 1140 3 1/2 54 9 1/2 217 15 1/2 430 21 1/2 668 27 1/2 912 33 1/2 1145 3 5/8 56 9 5/8 222 15 5/8 435 21 5/8 673 27 5/8 917 33 5/8 1149 3 3/4 59 9 3/4 226 15 3/4 440 21 3/4 678 27 3/4 922 33 3/4 1154 3 7/8 62 9 7/8 230 15 7/8 445 21 7/8 683 27 7/8 927 33 7/8 1158 4 65 10 234 16 450 22 688 28 932 34 1163 4 1/8 67 10 1/8 238 16 1/8 454 22 1/8 693 28 1/8 937 34 1/8 1168 4 1/4 70 10 1/4 242 16 1/4 459 22 1/4 699 28 1/4 942 34 1/4 1172 4 3/8 73 10 3/8 246 16 3/8 464 22 3/8 704 28 3/8 947 34 3/8 1177 4 1/2 76 10 1/2 250 16 1/2 469 22 1/2 709 28 1/2 952 34 1/2 1181 4 5/8 79 10 5/8 255 16 5/8 474 22 5/8 714 28 5/8 957 34 5/8 1186 4 3/4 82 10 3/4 259 16 3/4 479 22 3/4 719 28 3/4 962 34 3/4 1190 4 7/8 85 10 7/8 263 16 7/8 483 22 7/8 724 28 7/8 967 34 7/8 1195 5 88 11 267 17 488 23 729 29 972 35 1199 5 1/8 91 11 1/8 272 17 1/8 493 23 1/8 734 29 1/8 977 35 1/8 1203 5 1/4 94 11 1/4 276 17 1/4 498 23 1/4 739 29 1/4 982 35 1/4 1208 5 3/8 97 11 3/8 280 17 3/8 503 23 3/8 744 29 3/8 987 35 3/8 1212 5 1/2 101 11 1/2 284 17 1/2 508 23 1/2 749 29 1/2 992 35 1/2 1217 5 5/8 104 11 5/8 289 17 5/8 513 23 5/8 755 29 5/8 996 35 5/8 1221 5 3/4 107 11 3/4 293 17 3/4 518 23 3/4 760 29 3/4 1001 35 3/4 1225 5 7/8 110 11 7/8 298 17 7/8 523 23 7/8 765 29 7/8 1006 35 7/8 1230 6 114 12 302 18 528 24 770 30 1011 36 1234 Containment Solutions, Inc.1 (4') DWT-6 TYPE II 1,500 GALLON DIPSTICK GALLONS DIPSTICK GALLONS 36 1/8 1238 42 1/8 1420 36 1/4 1243 42 1/4 1423 36 3/8 1247 42 3/8 1426 36 1/2 1251 42 1/2 1429 36 5/8 1255 42 5/8 1432 36 3/4 1260 42 3/4 1435 36 7/8 1264 42 7/8 1438 37 1268 43 1441 37 1/8 1272 43 1/8 1444 37 1/4 1276 43 1/4 1447 37 3/8 1280 43 3/8 1450 37 1/2 1285 43 1/2 1452 37 5/8 1289 43 5/8 1455 37 3/4 1293 43 3/4 1458 37 7/8 1297 43 7/8 1460 38 1301 44 1463 38 1/8 1305 44 1/8 1466 38 1/4 1309 44 1/4 1468 38 3/8 1313 44 3/8 1471 38 1/2 1317 44 1/2 1473 38 5/8 1321 44 5/8 1475 38 3/4 1324 44 3/4 1478 38 7/8 1328 44 7/8 1480 39 1332 45 1482 39 1/8 1336 45 1/8 1485 39 1/4 1340 45 1/4 1487 39 3/8 1344 45 3/8 1489 39 1/2 1347 45 1/2 1491 39 5/8 1351 45 5/8 1493 39 3/4 1355 45 3/4 1495 39 7/8 1358 45 7/8 1497 40 1362 46 1498 40 1/8 1366 46 1/8 1500 40 1/4 1369 46 1/4 1502 40 3/8 1373 46 3/8 1503 40 1/2 1376 46 1/2 1505 40 5/8 1380 46 5/8 1506 40 3/4 1383 46 3/4 1508 40 7/8 1387 46 7/8 1509 41 1390 47 1510 41 1/8 1394 47 1/8 1511 41 1/4 1397 47 1/4 1512 41 3/8 1400 47 3/8 1513 41 1/2 1404 47 1/2 1514 41 5/8 1407 47 5/8 1514 41 3/4 1410 41 7/8 1414 42 1417 HOW TO PROPERLY GAUGE YOUR TANK: Underground storage tanks require periodic measurement to determine current inventory level.Using the proper methodswhen gauging your tank's contents will insure themost accurate reading and insure that you do not damage your tank.The following procedureshould be followed whenever you use a gauge stick to determine the amount of product that is in your tank: 1)Use a wood dipstick with a rubber or nylon tip.Metallic dipsticks arenot recommended.This will insure thatfrequenttank gaugings or an accidental dropping of the gauge stick into the tank will not damage the tank bottom. 2)Slowly lower your gauge stick into the fill port until it touches the tank bottom.Never free drop the gauge stick.This can result in inaccurate measurements due to product splashing. Free dropping can also result in gauge stick damage and tank damage. 3) Remove your dipstick slowly and read the product level directly from the gauge stick. Water Paste Detection To detect water in the tank bottom,water detection paste is available from petroleum equipment distributors.However,some water detection paste cannot detect antifreeze mixtures.If antifreeze mixtures are used for the cavity monitoring fluid,the following product is capable of detecting water or antifreeze (brine or up to 50 percent glycol) solution in the tank water bottoms: WATER FINDER #7686-1870 DAYCO/NATIONAL DAYTON, OH TEL: 1-800-283-2926 FAX: 1-800-688-4854 Caution Pressurized deliveries are not recommended.If the delivery vehicle uses pumps to fill the tank,install overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled.Overfilling the tank under pressure will damage the tank even if the tank vent is unrestricted. Containment Solutions, Inc. 5150 Jefferson Chemical Road Conroe, TX 77301 Tel: 936-756-7731 Fax: 936-756-7766 Note: Calibration chart is based on the fluid level above a 5/16" deflector plate. Pub. No. CAL 8415-DWT Containment Solutions, Inc.2 7901 XERXES AVENUE SOUTH MINNEAPOLIS, MN 55431-1288 www.xerxescorp.com 952-887-1890 CAUTION: Do not use the Calibration Chart without reviewing Xerxes® Installation Manual and Operating Guidelines, and Xerxes® applicable Limited Warranty, copies of which are in the literature packet delivered to the site, or available at www.xerxescorp.com. 0-1/8" 0-1/4" 0-3/8" 0-1/2" 0-5/8" 0-3/4" 0-7/8" 1" 1-1/8" 1-1/4" 1-3/8" 1-1/2" 1-5/8" 1-3/4" 1-7/8" 2" 2-1/8" 2-1/4" 2-3/8" 2-1/2" 2-5/8" 2-3/4" 2-7/8" 3" 3-1/8" 3-1/4" 3-3/8" 3-1/2" 3-5/8" 3-3/4" 3-7/8" 4" 4-1/8" 4-1/4" 4-3/8" 4-1/2" 4-5/8" 4-3/4" 4-7/8" 5" 5-1/8" 5-1/4" 5-3/8" 5-1/2" 5-5/8" 5-3/4" 5-7/8" 6" 6-1/8" 6-1/4" 6-3/8" 6-1/2" 6-5/8" 6-3/4" 6-7/8" 7" 7-1/8" 7-1/4" 7-3/8" 7-1/2" 7-5/8" 7-3/4" 7-7/8" 8" 8-1/8" 8-1/4" 8-3/8" 13 18 23 29 36 43 50 58 66 74 83 92 101 111 121 131 142 153 164 175 187 199 211 223 236 249 262 275 288 302 316 330 344 359 374 389 404 419 435 450 466 482 498 515 531 548 565 582 599 617 634 652 670 688 707 725 744 762 781 800 819 839 858 878 898 918 938 8-1/2" 8-5/8" 8-3/4" 8-7/8" 9" 9-1/8" 9-1/4" 9-3/8" 9-1/2" 9-5/8" 9-3/4" 9-7/8" 10" 10-1/8" 10-1/4" 10-3/8" 10-1/2" 10-5/8" 10-3/4" 10-7/8" 11" 11-1/8" 11-1/4" 11-3/8" 11-1/2" 11-5/8" 11-3/4" 11-7/8" 12" 12-1/8" 12-1/4" 12-3/8" 12-1/2" 12-5/8" 12-3/4" 12-7/8" 13" 13-1/8" 13-1/4" 13-3/8" 13-1/2" 13-5/8" 13-3/4" 13-7/8" 14" 14-1/8" 14-1/4" 14-3/8" 14-1/2" 14-5/8" 14-3/4" 14-7/8" 15" 15-1/8" 15-1/4" 15-3/8" 15-1/2" 15-5/8" 15-3/4" 15-7/8" 16" 16-1/8" 16-1/4" 16-3/8" 16-1/2" 16-5/8" 16-3/4" 16-7/8" 17" 17-1/8" 17-1/4" 17-3/8" 17-1/2" 17-5/8" 17-3/4" 17-7/8" 18" 18-1/8" 18-1/4" 18-3/8" 18-1/2" 18-5/8" 18-3/4" 18-7/8" 19" 19-1/8" 19-1/4" 19-3/8" 19-1/2" 19-5/8" 19-3/4" 19-7/8" 20" 20-1/8" 20-1/4" 20-3/8" 20-1/2" 20-5/8" 20-3/4" 20-7/8" 21" 21-1/8" 21-1/4" 21-3/8" 21-1/2" 21-5/8" 21-3/4" 21-7/8" 22" 22-1/8" 22-1/4" 22-3/8" 22-1/2" 22-5/8" 22-3/4" 22-7/8" 23" 23-1/8" 23-1/4" 23-3/8" 23-1/2" 23-5/8" 23-3/4" 23-7/8" 24" 24-1/8" 24-1/4" 24-3/8" 24-1/2" 24-5/8" 24-3/4" 24-7/8" 25" 25-1/8" 25-1/4" 25-3/8" 25-1/2" 25-5/8" 25-3/4" 25-7/8" 26" 26-1/8" 26-1/4" 26-3/8" 26-1/2" 26-5/8" 26-3/4" 26-7/8" 27" 27-1/8" 27-1/4" 27-3/8" 27-1/2" 27-5/8" 27-3/4" 27-7/8" 28" 28-1/8" 28-1/4" 28-3/8" 28-1/2" 28-5/8" 28-3/4" 28-7/8" 29" 29-1/8" 29-1/4" 29-3/8" 29-1/2" 29-5/8" 29-3/4" 29-7/8" 30" 30-1/8" 30-1/4" 30-3/8" 30-1/2" 30-5/8" 30-3/4" 30-7/8" 31" 31-1/8" 31-1/4" 31-3/8" 31-1/2" 31-5/8" 31-3/4" 31-7/8" 32" 32-1/8" 32-1/4" 32-3/8" 32-1/2" 32-5/8" 32-3/4" 32-7/8" 33" 33-1/8" 33-1/4" 33-3/8" 33-1/2" 33-5/8" 33-3/4" 33-7/8" 34" 34-1/8" 34-1/4" 34-3/8" 34-1/2" 34-5/8" 34-3/4" 34-7/8" 35" 35-1/8" 35-1/4" 35-3/8" 35-1/2" 35-5/8" 35-3/4" 35-7/8" 36" 36-1/8" 36-1/4" 36-3/8" 36-1/2" 36-5/8" 36-3/4" 36-7/8" 37" 37-1/8" 37-1/4" 37-3/8" 37-1/2" 37-5/8" 37-3/4" 37-7/8" 38" 38-1/8" 38-1/4" 38-3/8" 38-1/2" 38-5/8" 38-3/4" 38-7/8" 39" 39-1/8" 39-1/4" 39-3/8" 39-1/2" 39-5/8" 39-3/4" 39-7/8" 40" 40-1/8" 40-1/4" 40-3/8" 40-1/2" 40-5/8" 40-3/4" 40-7/8" 41" 41-1/8" 41-1/4" 41-3/8" 41-1/2" 41-5/8" 41-3/4" 41-7/8" 42" 42-1/8" 42-1/4" 42-3/8" 42-1/2" 42-5/8" 42-3/4" 42-7/8" 43" 43-1/8" 43-1/4" 43-3/8" 43-1/2" 43-5/8" 43-3/4" 43-7/8" 44" 44-1/8" 44-1/4" 44-3/8" 44-1/2" 44-5/8" 44-3/4" 44-7/8" 45" 45-1/8" 45-1/4" 45-3/8" 45-1/2" 45-5/8" 45-3/4" 45-7/8" 46" 46-1/8" 46-1/4" 46-3/8" 46-1/2" 46-5/8" 46-3/4" 46-7/8" 47" 47-1/8" 47-1/4" 47-3/8" 47-1/2" 47-5/8" 47-3/4" 47-7/8" 48" 48-1/8" 48-1/4" 48-3/8" 48-1/2" 48-5/8" 48-3/4" 48-7/8" 49" 49-1/8" 49-1/4" 49-3/8" 49-1/2" 49-5/8" 49-3/4" 49-7/8" 50" 50-1/8" 50-1/4" 50-3/8" 50-1/2" 50-5/8" 50-3/4" 50-7/8" 51" 51-1/8" 51-1/4" 51-3/8" 51-1/2" 51-5/8" 51-3/4" 51-7/8" 52" 52-1/8" 52-1/4" 52-3/8" 52-1/2" 52-5/8" 52-3/4" 52-7/8" 53" 53-1/8" 53-1/4" 53-3/8" 53-1/2" 53-5/8" 53-3/4" 53-7/8" 54" 54-1/8" 54-1/4" 54-3/8" 54-1/2" 54-5/8" 54-3/4" 54-7/8" 55" 55-1/8" 55-1/4" 55-3/8" 55-1/2" 55-5/8" 55-3/4" 55-7/8" 56" 56-1/8" 56-1/4" 56-3/8" 56-1/2" 56-5/8" 56-3/4" 56-7/8" 57" 57-1/8" 57-1/4" 57-3/8" 57-1/2" 57-5/8" 57-3/4" 57-7/8" 58" 58-1/8" 58-1/4" 58-3/8" 58-1/2" 58-5/8" DIPSTICKREADING GALLONS DIPSTICKREADING GALLONS DIPSTICKREADING GALLONS DIPSTICKREADING GALLONS DIPSTICKREADING GALLONS DIPSTICKREADING GALLONS DIPSTICKREADING GALLONS Dipstick Calibration Chart for 30,000 Gallon - 10' Diameter DWT-II Tank 958 978 999 1019 1040 1061 1082 1103 1124 1146 1167 1189 1211 1233 1255 1277 1300 1322 1345 1367 1390 1413 1436 1459 1483 1506 1530 1554 1577 1601 1625 1649 1674 1698 1722 1747 1772 1797 1822 1847 1872 1892 1922 1948 1973 1999 2025 2051 2077 2103 2129 2155 2182 2208 2235 2261 2288 2315 2342 2369 2396 2424 2451 2478 2506 2534 2561 2589 2617 2645 2673 2702 2730 2758 2787 2815 2844 2873 2902 2930 2959 2989 3018 3047 3076 3106 3135 3165 3195 3224 3254 3284 3314 3344 3374 3405 3435 3465 3496 3526 3557 3588 3619 3649 3680 3711 3743 3774 3805 3836 3868 3899 3931 3962 3994 4026 4058 4090 4122 4154 4186 4218 4250 4283 4315 4348 4380 4413 4445 4478 4511 4544 4577 4610 4643 4676 4709 4743 4776 4809 4843 4876 4910 4944 4977 5011 5045 5079 5113 5147 5181 5215 5249 5284 5318 5352 5387 5421 5456 5490 5525 5560 5595 5630 5664 5699 5734 5769 5805 5840 5875 5910 5946 5981 6017 6052 6088 6123 6159 6195 6230 6266 6302 6338 6374 6410 6446 6482 6518 6555 6591 6627 6664 6700 6736 6773 6809 6846 6883 6919 6956 6993 7030 7067 7104 7141 7178 7215 7252 7289 7326 7363 7401 7438 7475 7513 7550 7588 7625 7663 7700 7738 7776 7813 7851 7889 7927 7965 8003 8041 8079 8117 8155 8193 8231 8269 8308 8346 8384 8423 8461 8499 8538 8576 8615 8653 8692 8731 8769 8808 8847 8885 8924 8963 9002 9041 9080 9119 9158 9197 9236 9275 9314 9353 9392 9431 9471 9510 9549 9589 9628 9667 9707 9746 9786 9825 9865 9904 9944 9983 10023 10063 10102 10142 10182 10222 10261 10301 10341 10381 10421 10461 10501 10541 10581 10621 10661 10701 10741 10781 10821 10861 10901 10941 10982 11022 11062 11102 11143 11183 11223 11264 11304 11344 11385 11425 11466 11506 11547 11587 11628 11668 11709 11749 11790 11830 11871 11912 11952 11993 12034 12074 12115 12156 12197 12237 12278 12319 12360 12401 12441 12482 12523 12564 12605 12646 12687 12728 12768 12809 12850 12891 12932 12973 13014 13055 13096 13137 13178 13219 13260 13301 13343 13384 13425 13466 13507 13548 13589 13630 13671 13713 13754 13795 13836 13877 13918 13960 14001 14042 14083 14124 14166 14207 14248 14289 14330 14372 14413 14454 14495 14537 14578 14619 14660 14701 14743 14784 14825 14866 14908 14949 XerXes CorporaTIon Dipstick Calibration Chart for 30,000 Gallon - 10' Diameter DWT-II Tank DIPSTICK READING GALLONS DIPSTICK READING GALLONS DIPSTICK READING GALLONS DIPSTICK READING GALLONS DIPSTICK READING GALLONS DIPSTICK READING GALLONS DIPSTICKREADING GALLONS 58-3/4" 58-7/8" 59" 59-1/8" 59-1/4" 59-3/8" 59-1/2" 59-5/8" 59-3/4" 59-7/8" 60" 60-1/8" 60-1/4" 60-3/8" 60-1/2" 60-5/8" 60-3/4" 60-7/8" 61" 61-1/8" 61-1/4" 61-3/8" 61-1/2" 61-5/8" 61-3/4" 61-7/8" 62" 62-1/8" 62-1/4" 62-3/8" 62-1/2" 62-5/8" 62-3/4" 62-7/8" 63" 63-1/8" 63-1/4" 63-3/8" 63-1/2" 63-5/8" 63-3/4" 63-7/8" 64" 64-1/8" 64-1/4" 64-3/8" 64-1/2" 64-5/8" 64-3/4" 64-7/8" 65" 65-1/8" 65-1/4" 65-3/8" 65-1/2" 65-5/8" 65-3/4" 65-7/8" 66" 66-1/8" 66-1/4" 66-3/8" 66-1/2" 66-5/8" 66-3/4" 66-7/8" 67" 67-1/8" 67-1/4" 67-3/8" 67-1/2" 67-5/8" 67-3/4" 67-7/8" 68" 68-1/8" 68-1/4" 68-3/8" 68-1/2" 68-5/8" 68-3/4" 68-7/8" 69" 69-1/8" 69-1/4" 69-3/8" 69-1/2" 69-5/8 69-3/4" 69-7/8" 70" 70-1/8" 70-1/4" 70-3/8" 70-1/2" 70-5/8" 70-3/4" 70-7/8" 71" 71-1/8" 71-1/4" 71-3/8" 71-1/2" 71-5/8" 71-3/4" 71-7/8" 72" 72-1/8" 72-1/4"72-3/8" 72-1/2" 72-5/8" 72-3/4" 72-7/8" 73" 73-1/8" 73-1/4" 73-3/8" 73-1/2" 73-5/8" 73-3/4" 73-7/8" 74" 74-1/8" 74-1/4" 74-3/8" 74-1/2" 74-5/8" 74-3/4" 74-7/8" 75" 75-1/8" 75-1/4" 75-3/8" 75-1/2" 75-5/8" 75-3/4" 75-7/8" 76" 76-1/8" 76-1/4" 76-3/8" 76-1/2" 76-5/8" 76-3/4" 76-7/8" 77" 77-1/8" 77-1/4" 77-3/8" 77-1/2" 77-5/8" 77-3/4" 77-7/8" 78" 78-1/8" 78-1/4" 78-3/8" 78-1/2" 78-5/8" 78-3/4" 78-7/8" 79" 79-1/8" 79-1/4" 79-3/8" 79-1/2" 79-5/8" 79-3/4" 79-7/8" 80" 80-1/8" 80-1/4" 80-3/8" 80-1/2" 80-5/8" 80-3/4" 80-7/8" 81" 81-1/8" 81-1/4" 81-3/8" 81-1/2" 81-5/8" 81-3/4" 81-7/8" 82" 82-1/8" 82-1/4" 82-3/8" 82-1/2" 82-5/8" 82-3/4" 82-7/8" 83" 83-1/8" 83-1/4" 83-3/8" 83-1/2" 83-5/8" 83-3/4" 83-7/8" 84" 84-1/8" 84-1/4" 84-3/8" 84-1/2" 84-5/8" 84-3/4" 84-7/8" 85" 85-1/8" 85-1/4" 85-3/8" 85-1/2" 85-5/8" 85-3/4" 85-7/8" 86" 86-1/8" 86-1/4" 86-3/8" 86-1/2" 86-5/8" 86-3/4" 86-7/8" 87" 87-1/8" 87-1/4" 87-3/8" 87-1/2" 87-5/8" 87-3/4" 87-7/8" 88" 88-1/8" 88-1/4" 88-3/8" 88-1/2" 88-5/8" 88-3/4" 88-7/8" 89" 89-1/8" 89-1/4" 89-3/8" 89-1/2" 89-5/8" 89-3/4" 89-7/8" 90" 90-1/8" 90-1/4" 90-3/8" 90-1/2" 90-5/8" 90-3/4" 90-7/8" 91" 91-1/8" 91-1/4" 91-3/8" 91-1/2" 91-5/8" 91-3/4" 91-7/8" 92" 92-1/8" 92-1/4" 92-3/8" 92-1/2" 92-5/8" 92-3/4" 92-7/8" 93" 93-1/8" 93-1/4" 93-3/8" 93-1/2" 93-5/8" 93-3/4" 93-7/8" 94" 94-1/8" 94-1/4" 94-3/8" 94-1/2" 94-5/8" 94-3/4" 94-7/8" 95" 95-1/8" 95-1/4" 95-3/8" 95-1/2" 95-5/8" 95-3/4" 95-7/8" 96" 96-1/8" 96-1/4" 96-3/8" 96-1/2" 96-5/8" 96-3/4" 96-7/8" 97" 97-1/8" 97-1/4" 97-3/8" 97-1/2" 97-5/8" 97-3/4" 97-7/8" 98" 98-1/8" 98-1/4" 98-3/8" 98-1/2" 98-5/8" 98-3/4" 98-7/8" 99" 99-1/8" 99-1/4" 99-3/8" 99-1/2" 99-5/8" 99-3/4" 99-7/8" 100" 100-1/8" 100-1/4" 100-3/8" 100-1/2" 100-5/8" 100-3/4" 100-7/8" 101" 101-1/8" 101-1/4" 101-3/8" 101-1/2" 101-5/8" 101-3/4" 101-7/8" 102" 102-1/8" 102-1/4" 102-3/8" 102-1/2" 102-5/8" 102-3/4" 102-7/8" 103" 103-1/8" 103-1/4" 103-3/8" 103-1/2" 103-5/8" 103-3/4" 103-7/8" 104" 104-1/8" 104-1/4" 104-3/8" 104-1/2" 104-5/8" 104-3/4" 104-7/8" 105" 105-1/8" 105-1/4" 105-3/8" 105-1/2" 105-5/8" 105-3/4" 105-7/8" 106" 106-1/8" 106-1/4" 106-3/8" 106-1/2" 106-5/8" 106-3/4" 106-7/8" 107" 107-1/8" 107-1/4" 107-3/8" 107-1/2" 107-5/8" 107-3/4" 107-7/8" 108" 108-1/8" 108-1/4" 108-3/8" 108-1/2" 108-5/8" 108-3/4" 108-7/8" 109" 109-1/8" 109-1/4" 109-3/8" 109-1/2" 109-5/8" 109-3/4" 109-7/8" 110" 110-1/8" 110-1/4" 110-3/8" 110-1/2" 110-5/8" 110-3/4" 110-7/8" 111" 111-1/8" 111-1/4" 111-3/8" 111-1/2" 111-5/8" 111-3/4" 111-7/8" 112" 112-1/8" 112-1/4" 112-3/8" 112-1/2" 112-5/8" 112-3/4" 112-7/8" 113" 113-1/8" 113-1/4" 113-3/8" 113-1/2" 113-5/8" 113-3/4" 113-7/8" 114" 114-1/8" 114-1/4" 114-3/8" 114-1/2" 114-5/8" 114-3/4" 114-7/8" 115" 115-1/8" 115-1/4" 115-3/8" 115-1/2" 115-5/8" 115-3/4" 115-7/8" 116" 116-1/8" 116-1/4" 116-3/8" 116-1/2" 116-5/8" 116-3/4" 116-7/8" 117" 117-1/8" 117-1/4" 117-3/8" 117-1/2" 117-5/8" 117-3/4" 117-7/8" 118" 118-1/8" 118-1/4" 14990 15031 15073 15114 15155 15196 15238 15279 15320 15361 15403 15444 15485 15526 15568 15609 15650 15691 15733 15774 15815 15856 15897 15939 15980 16021 16062 16103 16145 16186 16227 16268 16309 16350 16392 16433 16474 16515 16556 16597 16638 16679 16720 16761 16803 16844 16885 16926 16967 17008 17049 17090 17131 17172 17213 17254 17294 17335 17376 17417 17458 17499 17540 17581 17622 17662 17703 17744 17785 17826 17866 17907 17948 17989 18029 18070 18111 18151 18192 18232 18273 18314 18354 18395 18435 18476 18516 18557 18597 18638 18678 18719 18759 18799 18840 18880 18920 18961 19001 19041 19081 19122 19162 19202 19242 19282 19322 19362 19402 19442 19482 19522 19562 19602 19642 19682 19722 19762 19802 19841 19881 19921 19961 20000 20040 20080 20119 20159 20198 20238 20277 20317 20356 20396 20435 20474 20514 20553 20592 20631 20671 20710 20749 20788 20827 20866 20905 20944 20983 21022 21061 21100 21139 21178 21216 21255 21294 21332 21371 21410 21448 21487 21525 21564 21602 21640 21679 21717 21755 21794 21832 21870 21908 21946 21984 22022 22060 22098 22136 22174 22212 22249 22287 22325 22363 22400 22438 22475 22513 22550 22588 22625 22662 22700 22737 22774 22811 22848 22885 22922 22959 22996 23033 23070 23107 23144 23180 23217 23253 23290 23327 23363 23399 23436 23472 23508 23545 23581 23617 23653 23689 23725 23761 23797 23833 23868 23904 23940 23975 24011 24046 24082 24117 24153 24188 24223 24258 24293 24329 24364 24399 24433 24468 24503 24538 24572 24607 24642 24676 24711 24745 24779 24814 24848 24882 24916 24950 24984 25018 25052 25086 25119 25153 25187 25220 25254 25287 2532025354 25387 25420 25453 25486 25519 25552 25585 25618 25650 25683 25715 25748 25780 25813 25845 25877 25909 25941 25973 26005 26037 26069 26100 26132 26164 26195 26227 26258 26289 26320 26351 26382 26413 26444 26475 26506 26537 26567 26598 26628 26658 26689 26719 26749 26779 26809 26839 26868 26898 26928 26957 26987 27016 27045 27074 27104 27133 27161 27190 27219 27248 27276 27305 27333 27361 27390 27418 27446 27474 27502 27529 27557 27584 27612 27639 27667 27694 27721 27748 27775 27802 27828 27855 27881 27908 27934 27960 27986 28012 28038 28064 28090 28115 28141 28166 28191 28216 28241 28266 28291 28316 28340 28365 28389 28414 28438 28462 28486 28509 28533 28557 28580 28603 28627 28650 28673 28696 28718 28741 28763 28786 28808 28830 28852 28874 28895 28917 28938 28960 28981 29002 29023 29044 29064 29084 29105 29125 29145 29165 29185 29205 29224 29244 29263 29282 29301 29319 29338 29356 29375 29393 29411 29428 29446 29463 29481 29498 29515 29532 29548 29565 29581 29597 29613 29628 29644 29659 29674 29689 29704 29719 29733 29747 29761 29775 29788 29801 29814 29827 29840 29852 29864 29876 29888 29899 29910 29921 29931 29942 29952 29961 29971 29980 29989 29997 30005 30013 30020 30027 30034 30040 30045 30050 30055 30058 30061 30063 30063 x1030D2.0 - 07/05fbf 24 Overfill Protection Testing Scope This procedure will provide a Veeder-Root ATG certified technician a procedure to safely test tank overfill protection. Reference Documents •Veeder-Root TLS-3XX Operators Manual (576013-610) •Veeder-Root TLS-3XX Setup Manual (576013-623) •Veeder-Root TLS-450 Setup and Operation Screens Manual (577013-940) •Veeder-Root TLS-450PLUS/TLS4 Operator’s Manual (577014-110) •Veeder-Root TLS4 Quick Start (577014-034) •Veeder-Root Overfill Alarm Installation Guide (576013-589) Consoles TLS-450PLUS, TLS4c, TLS4i, TLS-450 and TLS3XX Requirements TLS-450PLUS, TLS4c, TLS4i, TLS-450: Automatic Event: Device Task programmed to trigger on Tank Overfill and close a relay feeding voltage to the Overfill alarm device. TLS-3XX: Output relay programmed to close a relay on a Tank Overfill alarm feeding voltage to the Overfill alarm device. Testing Procedure 1. Inspection a. Verify the levels in the tank to make sure there is product in the tank and that the tank is enabled. b. If the site is currently receiving a delivery, wait until the delivery is complete. c. If the tank is performing a SLD tank test, stop the test. 2. Preparation a. Turn Alarm filtering off, as this will allow you to clear alarms quicker. Refer to TLS-3XX Setup manual (576013-623) or TLS4XX on-line help. b. Program Delivery delay to 1 minute, this will allow the delivery to be completed quicker. 1. Note the customers original value, so you can restore it after the test. Overfill Protection Testing Testing Procedure 25 c. Print the Tank Inventory Report. d. Test the relay assigned to the external Overfill alarm (if present) to insure the Overfill alarm works. 1. If the Overfill alarm does not sound, repair the device before continuing testing. Testing ATurn off power to the console. BDisconnect the probe from the field wiring and remove it from the riser. If you are testing more than one tank remove all the probes from their risers. CLay the probe safely on the ground and reattach the field wiring. DPosition the water float at the bottom of the probe and the product float 25% up from the bottom of the probe. EPower the console back on. FSimulate a delivery as follows: Move the float towards the top of the probe at a rate of 1-2” per ten seconds. Continue moving the float to the top of the probe at a rate of 1-2” per ten seconds for the next 50 seconds, the probe is noW in delivery mode. Slide the float at a moderate speed to the top of the probe. Note to not slam the float against the head of the probe, this can damage the float. GOnce the float reaches the overfill level the Overfill alarm, including external Overfill alarm (if present), will sound. HSilence the Overfill alarm on the TLS and external Overfill alarm (if present) by acknowledging it. IMove the float down to the bottom of the probe. The TLS will clear the Overfill alarm once the delivery delay time is complete. JRepeat 3f - 3i for the other probes. Test Completion APrint out the delivery report for all tanks tested. BPower off the console. CReplace the probes back into the tank; before inserting into riser, ensure that the floats are positioned at the bottom of the probe. DPower on the console. EIf the console is running BIR enter a manual adjustment for the amount of the delivery. FIf the site is not running BIR give the delivery report to the store manager so they can log the delivery as part of the overfill testing.