Loading...
HomeMy WebLinkAboutSB989 2024 Appendix VII Underground Storage Tank Secondary Containment Testing Report Form CERS = California Environmental Reporting System, ICC = International Code Council, ID = Identification, NA = Not Applicable, UDC = Under-Dispenser Containment, Page 1 of 5 TYPE OF ACTION ☐ Installation ☐ Repair ☐ 6 Month X 36 Month CERS ID 10023058 Test Date 6/6/2024 Facility Name ARCO White Ln Facility Address 6450 White Ln City Bakersfield, Ca ZIP Code 93309 Company Performing the Test Advanced Compliance Phone 6617064321 Mailing Address 4007 Brae Burn Dr Bakersfield Ca 93306 Service Technician Performing Test Bradley Hinsley Contractor/Tank Tester License Number 971259 ICC Number 8835007 ICC Expiration Date 8/8/2025 Manufacturer and Test Equipment Training Certifications Expiration Date ICC Service Techican 8/8/2025 INCON STS 10/20/2025 Test Procedures Used Components Tested PEI/RP1200-19 Sect. 4. Tank Annular PEI/RP1200-19 Sect. 5. Line Secondary PEI/RP1200-19 Sect. 6. Containment Sump I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 6/6/2024 Total # of Pages 1. FACILITY INFORMATION 2. SERVICE TECHNICIAN INFORMATION 3. TRAINING AND CERTIFICATIONS 4. TEST PROCEDURE INFORMATION 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 2 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure X Vacuum ☐ Hydrostatic Test Equipment Used: Tank Annular Testing Setups Tank ID 87S 87M 91 Tank Manufacturer Unknown Unknown Unknown Tank Capacity 11,627 11,627 11,627 Test Start Time 09:15 07:55 10:40 Initial Reading -10.00 InHg -10.00 InHg -10.00 InHg Test End Time 10:15 08:55 11:40 Final Reading -10.00 InHg -10.00 InHg -10.00 InHg Change in Reading 0.0 InHg 0.0 InHg 0.0 InHg Pass/Fail Criteria +/- 0.0 InHg +/- 0.0 InHg +/- 0.0 InHg Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass ☐ Fail Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type X Pressure ☐ Vacuum ☐ Hydrostatic Test Equipment Used: Line Secondary Testing Setup Pipe Run ID 87S Line 87M Line 91 Line Pipe Manufacturer Unknown Unknown Unknown Test Start Time 07:50 07:45 08:10 Initial Reading 5.0 PSI 5.0 PSI 5.0 PSI Test End Time 08:50 08:45 09:10 Final Reading 5.0 PSI 5.0 PSI 5.0 PSI Change in Reading 0.0 PSI 0.0 PSI 0.0 PSI Pass/Fail Criteria +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass ☐ Fail Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 6. TANK SECONDARY CONTAINMENT TEST 7. PIPE SECONDARY CONTAINMENT TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 3 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: INCON STS Sump/UDC ID 87S FS 87M FS 91 FS 87S STP Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 45 45 45 40 Sump Bottom to Top of Highest Pipe Penetration (inches) 10 10 10 30 Test Start Time 12:46 12:19 11:20 10:30 Initial Reading 2.2773 2.9664 2.7324 4.7637 Test End Time 13:01 12:34 11:35 10:45 Final Reading 2.2781 2.9682 2.7339 4.7633 Change in Reading 0.0008 0.0018 0.0015 0.0004 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail Sump/UDC ID 87M STP 91 STP UDC 1/2 UDC 3/4 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 40 40 13 13 Sump Bottom to Top of Highest Pipe Penetration (inches) 30 30 4 4 Test Start Time 09:52 10:53 14:09 14:27 Initial Reading 5.0077 4.2690 0.2288 0.9510 Test End Time 10:07 11:08 14:24 14:42 Final Reading 5.0081 4.2687 0.2285 0.9493 Change in Reading 0.0004 0.0003 0.0003 0.0017 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 4 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: INCON STS Sump/UDC ID UDC 5/6 UDC 7/8 UDC 9/10 UDC 11/12 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 40 13 13 40 Sump Bottom to Top of Highest Pipe Penetration (inches) 28 4 4 28 Test Start Time 15:05 12:46 13:14 14:27 Initial Reading 4.9725 1.0318 0.9406 6.1007 Test End Time 15:20 13:01 13:30 14:42 Final Reading 4.9735 1.0315 0.9405 6.1013 Change in Reading 0.0010 0.0003 0.0001 0.0006 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST (continued) Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 5 of 5 All Passed. 9. COMMENTS