HomeMy WebLinkAbout2024 SB989 Appendix VII Underground Storage Tank Secondary Containment Testing Report Form CERS = California Environmental Reporting System, ICC = International Code Council, ID = Identification, NA = Not Applicable, UDC = Under-Dispenser Containment, Page 1 of 5 TYPE OF ACTION ☐ Installation ☐ Repair ☐ 6 Month X 36 Month CERS ID 10132174 Test Date 5/31/2024 Facility Name ARCO Fst Facility Address 2301 F Street City Bakersfield ZIP Code 93301 Company Performing the Test Advanced Compliance Phone 6617064321 Mailing Address 4007 Brae Burn Dr Bakersfield Ca 93306 Service Technician Performing Test Bradley Hinsley Contractor/Tank Tester License Number 971259 ICC Number 8835007 ICC Expiration Date 8/8/2025 Manufacturer and Test Equipment Training Certifications Expiration Date ICC Service Techican 8/8/2025 INCON STS 10/20/2025 Test Procedures Used Components Tested PEI/RP1200-19 Sect. 4. Tank Annular PEI/RP1200-19 Sect. 5. Line Secondary PEI/RP1200-19 Sect. 6. Containment Sump I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 5/31/2024 Total # of Pages 1. FACILITY INFORMATION 2. SERVICE TECHNICIAN INFORMATION 3. TRAINING AND CERTIFICATIONS 4. TEST PROCEDURE INFORMATION 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 2 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure X Vacuum ☐ Hydrostatic Test Equipment Used: Tank Annular Testing Setup Tank ID 87S 87M 91 Tank Manufacturer Unknown Unknown Unknown Tank Capacity 10,369 19,703 10,369 Test Start Time 11:50 10:05 11:50 Initial Reading -10.00 InHg -10.00 InHg -10.00 InHg Test End Time 12:50 11:05 12:50 Final Reading -10.00 InHg -10.00 InHg -10.00 InHg Change in Reading 0.0 InHg 0.0 InHg 0.0 InHg Pass/Fail Criteria +/- 0.0 InHg +/- 0.0 InHg +/- 0.0 InHg Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass ☐ Fail Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type X Pressure ☐ Vacuum ☐ Hydrostatic Test Equipment Used: Piping Secondary Testing Setup Pipe Run ID 87S Product 87M Product 91 Product Pipe Manufacturer Unknown Unknown Unknown Test Start Time 10:35 10:40 10:38 Initial Reading 5.0 PSI 5.0 PSI 5.0 PSI Test End Time 11:35 11:40 11:38 Final Reading 5.0 PSI 5.0 PSI 5.0 PSI Change in Reading 0.0 PSI 0.0 PSI 0.0 PSI Pass/Fail Criteria +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass ☐ Fail Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 6. TANK SECONDARY CONTAINMENT TEST 7. PIPE SECONDARY CONTAINMENT TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 3 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: Incon STS Sump/UDC ID 87M STP 87S STP 91 STP UDC 1/2 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 68 68 68 30 Sump Bottom to Top of Highest Pipe Penetration (inches) 43 43 44 19 Test Start Time 14:44 13:50 11:52 18:19 Initial Reading 2.1440 2.8628 7.1283 5.6472 Test End Time 14:59 14:05 12:07 18:34 Final Reading 2.1445 2.8619 7.1275 5.1184 Change in Reading 0.0005 0.0009 0.0008 0.5288 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass X Fail Sump/UDC ID UDC 3/4 UDC 5/6 UDC 7/8 UDC 9/10 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 30 30 30 30 Sump Bottom to Top of Highest Pipe Penetration (inches) 19 19 19 19 Test Start Time 16:32 16:32 15:21 17:43 Initial Reading 6.5981 4.5858 3.2301 6.9317 Test End Time 16:48 16:48 15:36 17:59 Final Reading 6.3247 4.5812 3.2311 6.9315 Change in Reading 0.2734 0.0046 0.0010 0.0002 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results ☐ Pass X Fail ☐ Pass X Fail X Pass ☐ Fail X Pass ☐ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 4 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: INCON STS Sump/UDC ID UDC 11/12 UDC 13/14 UDC 15/16 Sump Manufacturer Unknown Unknown Unknown Sump Depth (inches) 30 30 30 Sump Bottom to Top of Highest Pipe Penetration (inches) 19 19 19 Test Start Time 17:22 17:43 16:52 Initial Reading 3.5298 3.8550 4.5640 Test End Time 17:37 17:59 17:07 Final Reading 3.5288 3.8549 4.5633 Change in Reading 0.0010 0.0001 0.0007 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass ☐ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST (continued) Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 5 of 5 Disp 1/2, 3/4 and 5/6 failed hydrostatic testing, must be repaired and retested. 9. COMMENTS