Loading...
HomeMy WebLinkAboutFMC 2024Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10120951 06/19/2024 Mesa Marin Chevron 11101 Highway 178 Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 VeederRoot TLS-3XX Technician - C32655 10/11/2024 Vaporless Manufacturing Inc. - #5265 10/24/2024 OPW - 1193585 04/14/2025 06/19/2024 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208/304 Dispenser 1-2 UDC L2 208/304 Dispenser 3-4 UDC L3 208/304 Dispenser 5-6 UDC L4 208/304 Dispenser 7-8 UDC L5 208/304 Dispenser 9-10 UDC L6 208/304 Dispenser 11-12 UDC L7 208/304 87 Unleaded STP L8 208/304 87 Unleaded Fill L9 208/304 91 Supreme STP L10 208/304 91 Supreme Fill L11 208/304 Diesel STP L12 208/304 Diesel Fill L13 208/304 Vent Box S9 463/464 / 420 Unleaded Tank S10 463/464 Unleaded Product S11 463/464 Vapor Return S12 463/464 / 420 Supreme Tank S13 463/464 Supreme Product S14 463/464 Unleaded-Supreme Vent S15 463/464 / 420 Diesel Tank S16 463/464 Diesel Product S17 463/464 Diesel Vent Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 Unleaded T2 FX1V 91 Supreme T3 FX1DV Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ All liquid sensors utilize a VR 2 to 1 Sensor Input Box connecting 208 and 304 sensors together. Audible visual alarms include Fuel Alarm & High Liquid Alarm All Tank Annular sensors are 420 sensors monitored under vacuum via 463/464 sensor. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 06/19/2024 APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Mesa Marin Chevron11101 Highway 178Bakersfield10120951Disp 3-4Disp 7-8 Disp 11-12MPDMPDMPDMPDMPDMPDDisp 1-2Disp 5-6Disp 9-10ProductProductProductProductProductProductBrandon Nunez Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10120951 06/19/2024 Mesa Marin Chevron 11101 Highway 178 Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 OPW - 1193585 04/14/2025 PEI 1200 1 Hour Hydrostatic All Spill Containers 06/19/2024 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1: 87 UNL OPW T2: 91 SUP OPW T3: DSL OPW Mesa Marin Chevron System Setup & Alarm History Responses Received: 200 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 JUN 19, 2024 8:47 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 9178 68.27 0.0 84.7 2854 2 SUPREME 5123 42.28 0.0 84.7 6909 3 DIESEL 4319 37.08 0.0 86.5 7756 I90500 JUN 19, 2024 8:47 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUN 19, 2024 8:47 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUN 19, 2024 8:47 AM SHIFT TIME 1 : 1:00 AM I50202 JUN 19, 2024 8:47 AM SHIFT TIME 2 : DISABLED I50203 JUN 19, 2024 8:47 AM SHIFT TIME 3 : DISABLED I50204 JUN 19, 2024 8:47 AM SHIFT TIME 4 : DISABLED I54600 JUN 19, 2024 8:47 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUN 19, 2024 8:47 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUN 19, 2024 8:47 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUN 19, 2024 8:47 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUN 19, 2024 8:47 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUN 19, 2024 8:47 AM PRINT TC VOLUMES ENABLED I50E00 JUN 19, 2024 8:47 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUN 19, 2024 8:47 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUN 19, 2024 8:47 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUN 19, 2024 8:47 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUN 19, 2024 8:47 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUN 19, 2024 8:47 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUN 19, 2024 8:47 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUN 19, 2024 8:47 AM TANK CHART SECURITY DISABLED I5BD00 JUN 19, 2024 8:47 AM CUSTOM ALARM LABELS DISABLED I56000 JUN 19, 2024 8:47 AM MASS/DENSITY DISABLED I88101 JUN 19, 2024 8:47 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUN 19, 2024 8:47 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUN 19, 2024 8:47 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 JUN 19, 2024 8:47 AM I88105 JUN 19, 2024 8:47 AM I88106 JUN 19, 2024 8:47 AM I52000 JUN 19, 2024 8:47 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 WEEKLY FRI 4:51 PM 2 WEEKLY FRI 4:51 PM 3 WEEKLY FRI 4:51 PM 4 WEEKLY FRI 4:51 PM 5 WEEKLY FRI 4:51 PM 6 WEEKLY FRI 4:51 PM 7 WEEKLY FRI 4:51 PM 8 VEEDER ROOT (FMS) WEEKLY FRI 4:51 PM I60100 JUN 19, 2024 8:47 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 SUPREME ON 3 DIESEL ON 4 OFF I60200 JUN 19, 2024 8:47 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 SUPREME 3 DIESEL 4 I60300 JUN 19, 2024 8:47 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 SUPREME 2 3 DIESEL 3 4 4 I60900 JUN 19, 2024 8:47 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 SUPREME 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 JUN 19, 2024 8:47 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 95.75 2 SUPREME 95.75 3 DIESEL 95.75 4 0.00 I60A00 JUN 19, 2024 8:47 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12032 2 SUPREME 1 PT 12032 3 DIESEL 1 PT 12075 4 1 PT 0 I60400 JUN 19, 2024 8:47 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 SUPREME 12032 3 DIESEL 12075 4 0 I60500 JUN 19, 2024 8:47 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 2 SUPREME 12032 0 0 0 3 DIESEL 12075 0 0 0 4 0 0 0 0 I60600 JUN 19, 2024 8:47 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 SUPREME 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12075 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUN 19, 2024 8:47 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 SUPREME NO 3 DIESEL NO 4 NO I62F00 JUN 19, 2024 8:47 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. PS 2 SUPREME 4.0 IN. PS 3 DIESEL 4.0 IN. I62700 JUN 19, 2024 8:47 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 SUPREME 2.0 3 DIESEL 2.0 I64200 JUN 19, 2024 8:47 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 SUPREME LOW 3 DIESEL LOW I62400 JUN 19, 2024 8:47 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 SUPREME 3.0 3 DIESEL 3.0 I62800 JUN 19, 2024 8:47 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 SUPREME 12032 3 DIESEL 12075 4 0 I62300 JUN 19, 2024 8:47 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10829 2 SUPREME 10829 3 DIESEL 10868 4 0 I62200 JUN 19, 2024 8:47 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11430 2 SUPREME 11430 3 DIESEL 11471 4 0 I62900 JUN 19, 2024 8:47 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 SUPREME 120 3 DIESEL 121 4 0 I62100 JUN 19, 2024 8:47 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 SUPREME 500 3 DIESEL 500 4 0 I62600 JUN 19, 2024 8:47 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 SUPREME 99 3 DIESEL 99 4 99 I62500 JUN 19, 2024 8:47 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 SUPREME 99 3 DIESEL 99 4 99 I60800 JUN 19, 2024 8:47 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 SUPREME 0.00 3 DIESEL 0.00 4 0.00 I60B00 JUN 19, 2024 8:47 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUN 19, 2024 8:47 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 SUPREME 0.00 3 DIESEL 0.00 4 0.00 I61200 JUN 19, 2024 8:47 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 SUPREME NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 JUN 19, 2024 8:47 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 SUPREME 120 3 DIESEL 120 4 0 I62A00 JUN 19, 2024 8:47 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 SUPREME 120 3 DIESEL 120 4 0 I62C00 JUN 19, 2024 8:47 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 SUPREME STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 JUN 19, 2024 8:47 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPREME GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUN 19, 2024 8:47 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 SUPREME OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 JUN 19, 2024 8:47 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 SUPREME OFF 3 DIESEL OFF 4 OFF I63200 JUN 19, 2024 8:47 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 SUPREME OFF 3 DIESEL OFF 4 OFF I61000 JUN 19, 2024 8:47 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 SUPREME 1 3 DIESEL 1 4 1 I63A00 JUN 19, 2024 8:47 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 SUPREME 10.00% 3 DIESEL 10.00% 4 10.00% I61100 JUN 19, 2024 8:47 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 2, 2019 START TIME : 2:00 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:ENABLED I61300 JUN 19, 2024 8:47 AM CSLD PROBABLITY OF DETECTION I61400 JUN 19, 2024 8:47 AM CSLD CLIMATE FACTOR I61600 JUN 19, 2024 8:47 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 SUPREME IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 JUN 19, 2024 8:47 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED ENABLED 2 SUPREME ENABLED 3 DIESEL ENABLED 4 ENABLED I61B00 JUN 19, 2024 8:47 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUN 19, 2024 8:47 AM CSLD REPORT ONLY I62B00 JUN 19, 2024 8:47 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 SUPREME ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 JUN 19, 2024 8:47 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUN 19, 2024 8:47 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 SUPREME 0 3 DIESEL 0 4 0 I63500 JUN 19, 2024 8:47 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 SUPREME 1 3 DIESEL 1 4 1 I63900 JUN 19, 2024 8:47 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 SUPREME END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 JUN 19, 2024 8:47 AM I77700 JUN 19, 2024 8:47 AM I77800 JUN 19, 2024 8:47 AM I78C00 JUN 19, 2024 8:47 AM I78300 JUN 19, 2024 8:47 AM I78F00 JUN 19, 2024 8:47 AM I78700 JUN 19, 2024 8:47 AM I70200 JUN 19, 2024 8:47 AM LIQUID LABEL DEVICE LABEL 1 DISP 1-2 2 DISP 3-4 3 DISP 5-6 4 DISP 7-8 5 DISP 9-10 6 DISP 11-12 7 UNL STP 8 UNL FILL 9 SUPREME STP 10 SUPREME FILL 11 DIESEL STP 12 DIESEL FILL 13 VENT BOX 14 15 16 I70300 JUN 19, 2024 8:47 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1-2 DW SUMP 2-1 2 DISP 3-4 DW SUMP 2-1 3 DISP 5-6 DW SUMP 2-1 4 DISP 7-8 DW SUMP 2-1 5 DISP 9-10 DW SUMP 2-1 6 DISP 11-12 DW SUMP 2-1 7 UNL STP DW SUMP 2-1 8 UNL FILL DW SUMP 2-1 9 SUPREME STP DW SUMP 2-1 10 SUPREME FILL DW SUMP 2-1 11 DIESEL STP DW SUMP 2-1 12 DIESEL FILL DW SUMP 2-1 13 VENT BOX DW SUMP 2-1 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUN 19, 2024 8:47 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1-2 DISPENSER PAN 2 DISP 3-4 DISPENSER PAN 3 DISP 5-6 DISPENSER PAN 4 DISP 7-8 DISPENSER PAN 5 DISP 9-10 DISPENSER PAN 6 DISP 11-12 DISPENSER PAN 7 UNL STP STP SUMP 8 UNL FILL OTHER SENSORS 9 SUPREME STP STP SUMP 10 SUPREME FILL OTHER SENSORS 11 DIESEL STP STP SUMP 12 DIESEL FILL OTHER SENSORS 13 VENT BOX OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUN 19, 2024 8:47 AM I74300 JUN 19, 2024 8:47 AM I74400 JUN 19, 2024 8:47 AM I74700 JUN 19, 2024 8:47 AM I74800 JUN 19, 2024 8:47 AM I74900 JUN 19, 2024 8:47 AM I7BC00 JUN 19, 2024 8:47 AM I80200 JUN 19, 2024 8:47 AM I80300 JUN 19, 2024 8:47 AM I80400 JUN 19, 2024 8:48 AM I80700 JUN 19, 2024 8:48 AM RELAY LABEL DEVICE LABEL 1 UNL 2 SUPREME 3 DIESEL 4 OVERFILL ALARM I80900 JUN 19, 2024 8:48 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL NORMALLY OPEN 2 SUPREME NORMALLY OPEN 3 DIESEL NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUN 19, 2024 8:48 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 2 SUPREME 2 3 DIESEL 3 4 OVERFILL ALARM NONE I80A00 JUN 19, 2024 8:48 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL PUMP CONTROL OUTPUT 2 SUPREME PUMP CONTROL OUTPUT 3 DIESEL PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD I80C00 JUN 19, 2024 8:48 AM I80800 JUN 19, 2024 8:48 AM RELAY SETUP REPORT R 1:UNL TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:SUPREME TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 2:FUEL ALARM L 6:FUEL ALARM L11:FUEL ALARM L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 2:SHORT ALARM L 6:SHORT ALARM L11:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUN 19, 2024 8:48 AM EDIM:1 VR:349867-001-D TD:17.02.14.08.38 I79100 JUN 19, 2024 8:48 AM I72300 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DISP 1-2 FM AIR FLOW METER 02 DISP 3-4 FM AIR FLOW METER 03 DISP 5-6 FM AIR FLOW METER 04 DISP 7-8 FM AIR FLOW METER 05 DISP 9-10 FM AIR FLOW METER 06 DISP 11-12 FM AIR FLOW METER 07 DISP 5-6 PS VAPOR PRESSURE 08 ATM ATM P SENSOR 09 UNL TANK VAC SENSOR 10 UNL PRODUCT VAC SENSOR 11 VAPOR RETURN VAC SENSOR 12 SUPREME TANK VAC SENSOR 13 SUPREME PRODUCT VAC SENSOR 14 UNL-SUP VENT VAC SENSOR 15 DIESEL TANK VAC SENSOR 16 DIESEL PRODUCT VAC SENSOR 17 DIESEL VENT VAC SENSOR 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 EVR/ISD SETUP TYPE: BALANCE IV4F00 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 VAPOR PROCESSOR TYPE NONE IV4700 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ACCEPT HIGH ORVR: YES IV4A00 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx 05 03 02/05 09/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 02/07 09/07 01/07 xx/xx 08 04 02/08 09/08 01/08 xx/xx 09 05 02/09 09/09 01/09 xx/xx 16 05 02/10 09/10 01/10 xx/xx 17 06 02/11 09/11 01/11 xx/xx 18 06 02/12 09/12 01/12 xx/xx IV4900 JUN 19, 2024 8:48 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUN 19, 2024 8:48 AM ISD VERSION: 01.06 Pre Alarm History Responses Received: I10200 JUN 19, 2024 8:49 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164126 164723 2 7SMARTSENSOR BD 505360 506774 3 8SMARTSENSOR BD 39330 39412 4 8SMARTSENSOR BD 39396 39456 5 INTERSTITIAL BD 201541 201891 6 INTERSTITIAL BD 201257 201520 7 UNUSED 4846706 4910091 8 UNUSED 4839908 4894164 9 RELAY BOARD 14963 14978 10 STP SENSE BOARD 33096 33131 11 UNUSED 4852892 4899328 12 UNUSED 4850212 4901485 13 UNUSED 4844743 4897898 14 UNUSED 4843327 4898346 15 UNUSED 4848970 4893222 16 UNUSED 4850147 4890404 COMM 1 ELEC DISP INT. 101203 101515 COMM 2 RS232 SERIAL BD 14897 14935 COMM 3 SERIAL SAT BD 480489 480938 COMM 4 UNUSED 4852979 4895571 COMM 5 UNUSED 4849885 4896275 COMM 6 UNUSED 4842259 4893649 I90200 JUN 19, 2024 8:49 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUN 19, 2024 8:49 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME E 1 OTHER COMMUNICATION ALARM CLEAR 6-17-24 4:23PM E 1 OTHER COMMUNICATION ALARM ALARM 6-17-24 4:23PM E 1 OTHER COMMUNICATION ALARM CLEAR 6-17-24 4:23PM E 1 OTHER COMMUNICATION ALARM ALARM 6-17-24 4:23PM E 1 OTHER COMMUNICATION ALARM CLEAR 6-17-24 2:04AM E 1 OTHER COMMUNICATION ALARM ALARM 6-17-24 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-10-24 2:04AM E 1 OTHER COMMUNICATION ALARM ALARM 6-10-24 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-07-24 10:42AM E 1 OTHER COMMUNICATION ALARM ALARM 6-07-24 10:41AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-07-24 10:32AM E 1 OTHER COMMUNICATION ALARM ALARM 6-07-24 10:32AM L 9 STP SUMP SUPREME STP FUEL ALARM CLEAR 6-07-24 7:54AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-07-24 7:05AM E 1 OTHER COMMUNICATION ALARM ALARM 6-07-24 7:05AM L 9 STP SUMP SUPREME STP FUEL ALARM ALARM 6-07-24 2:44AM E 1 OTHER COMMUNICATION ALARM CLEAR 6-04-24 3:41PM E 1 OTHER COMMUNICATION ALARM ALARM 6-04-24 3:41PM E 1 OTHER COMMUNICATION ALARM CLEAR 6-03-24 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 6-03-24 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 5-27-24 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 5-27-24 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 5-20-24 9:11AM E 1 OTHER COMMUNICATION ALARM ALARM 5-20-24 9:10AM E 1 OTHER COMMUNICATION ALARM CLEAR 5-20-24 8:53AM E 1 OTHER COMMUNICATION ALARM ALARM 5-20-24 8:52AM L10 OTHER SUPREME FILL SENSOR OUT ALARM CLEAR 5-20-24 8:17AM L 9 STP SUMP SUPREME STP LOW LIQUID ALARM CLEAR 5-20-24 8:16AM L 9 STP SUMP SUPREME STP LOW LIQUID ALARM ALARM 5-20-24 8:16AM L10 OTHER SUPREME FILL SENSOR OUT ALARM ALARM 5-20-24 8:14AM L10 OTHER SUPREME FILL LOW LIQUID ALARM CLEAR 5-20-24 8:13AM L 9 STP SUMP SUPREME STP LOW LIQUID ALARM CLEAR 5-20-24 8:08AM L10 OTHER SUPREME FILL LOW LIQUID ALARM ALARM 5-20-24 8:06AM L10 OTHER SUPREME FILL FUEL ALARM CLEAR 5-20-24 8:06AM L10 OTHER SUPREME FILL LOW LIQUID ALARM CLEAR 5-20-24 8:06AM L10 OTHER SUPREME FILL FUEL ALARM ALARM 5-20-24 8:06AM L10 OTHER SUPREME FILL LOW LIQUID ALARM ALARM 5-20-24 8:03AM L10 OTHER SUPREME FILL FUEL ALARM CLEAR 5-20-24 8:03AM L10 OTHER SUPREME FILL SENSOR OUT ALARM CLEAR 5-20-24 8:02AM L10 OTHER SUPREME FILL FUEL ALARM ALARM 5-20-24 8:02AM L10 OTHER SUPREME FILL LOW LIQUID ALARM CLEAR 5-20-24 8:01AM L10 OTHER SUPREME FILL SENSOR OUT ALARM ALARM 5-20-24 8:01AM L10 OTHER SUPREME FILL LOW LIQUID ALARM ALARM 5-20-24 8:01AM L10 OTHER SUPREME FILL LOW LIQUID ALARM CLEAR 5-20-24 7:59AM L10 OTHER SUPREME FILL LOW LIQUID ALARM ALARM 5-20-24 7:53AM L10 OTHER SUPREME FILL LOW LIQUID ALARM CLEAR 5-20-24 7:51AM L10 OTHER SUPREME FILL LOW LIQUID ALARM ALARM 5-20-24 7:47AM L10 OTHER SUPREME FILL FUEL ALARM CLEAR 5-20-24 7:47AM L10 OTHER SUPREME FILL LOW LIQUID ALARM CLEAR 5-20-24 7:46AM L10 OTHER SUPREME FILL FUEL ALARM ALARM 5-20-24 7:46AM I11200 JUN 19, 2024 8:49 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h12 OTHER FP12: BLEND3 FLOW COLLECT WARN CLEAR 6-07-24 8:14AM h12 OTHER FP12: BLEND3 FLOW COLLECT WARN ALARM 6-06-24 10:08AM SYSTEM PRINTER ERROR CLEAR 5-28-24 8:00AM SYSTEM PAPER OUT CLEAR 5-28-24 8:00AM SYSTEM PRINTER ERROR ALARM 5-28-24 8:00AM SYSTEM PAPER OUT ALARM 5-28-24 8:00AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN CLEAR 5-17-24 2:15PM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN ALARM 5-17-24 10:06AM SYSTEM PRINTER ERROR CLEAR 5-08-24 1:03AM SYSTEM PAPER OUT CLEAR 5-08-24 1:03AM SYSTEM PAPER OUT ALARM 5-08-24 1:03AM SYSTEM PRINTER ERROR ALARM 5-08-24 1:03AM SYSTEM PRINTER ERROR CLEAR 5-08-24 1:02AM SYSTEM PAPER OUT CLEAR 5-08-24 1:02AM SYSTEM PRINTER ERROR ALARM 5-08-24 1:02AM SYSTEM PRINTER ERROR CLEAR 5-08-24 1:02AM SYSTEM PRINTER ERROR ALARM 5-08-24 1:01AM SYSTEM PAPER OUT ALARM 5-08-24 1:00AM SYSTEM PRINTER ERROR CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT ALARM 4-17-24 11:49PM SYSTEM PRINTER ERROR ALARM 4-17-24 11:49PM SYSTEM PRINTER ERROR CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT ALARM 4-17-24 11:49PM SYSTEM PAPER OUT CLEAR 4-17-24 11:49PM SYSTEM PRINTER ERROR ALARM 4-17-24 11:48PM SYSTEM PAPER OUT ALARM 4-17-24 11:48PM SYSTEM PRINTER ERROR CLEAR 4-11-24 2:27PM SYSTEM PAPER OUT CLEAR 4-11-24 2:26PM SYSTEM PRINTER ERROR ALARM 4-11-24 2:26PM SYSTEM PAPER OUT ALARM 4-11-24 2:22PM SYSTEM PRINTER ERROR CLEAR 3-23-24 12:24AM SYSTEM PAPER OUT CLEAR 3-23-24 12:24AM SYSTEM PAPER OUT ALARM 3-23-24 12:24AM SYSTEM PRINTER ERROR ALARM 3-23-24 12:24AM SYSTEM PRINTER ERROR CLEAR 3-03-24 4:27AM SYSTEM PRINTER ERROR ALARM 3-03-24 4:27AM SYSTEM PAPER OUT CLEAR 3-03-24 4:27AM SYSTEM PAPER OUT ALARM 3-03-24 4:27AM SYSTEM PRINTER ERROR CLEAR 3-03-24 4:27AM SYSTEM PAPER OUT CLEAR 3-03-24 4:26AM SYSTEM PAPER OUT ALARM 3-03-24 4:26AM SYSTEM PAPER OUT CLEAR 3-03-24 4:26AM SYSTEM PAPER OUT ALARM 3-03-24 4:26AM SYSTEM PAPER OUT CLEAR 3-03-24 4:26AM SYSTEM PAPER OUT ALARM 3-03-24 4:26AM SYSTEM PAPER OUT CLEAR 3-03-24 4:26AM SYSTEM PAPER OUT ALARM 3-03-24 4:26AM SYSTEM PAPER OUT CLEAR 3-03-24 4:26AM I20600 JUN 19, 2024 8:50 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 SUPREME TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUN 19, 2024 8:50 AM I30200 JUN 19, 2024 8:50 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 JUL 24, 2023 2:03 PM FUEL ALARM JUL 24, 2023 2:03 PM LOW LIQUID ALARM FEB 13, 2021 8:05 AM SENSOR OUT ALARM 2 DISP 3-4 JUL 24, 2023 2:05 PM FUEL ALARM JUL 24, 2023 2:04 PM LOW LIQUID ALARM FEB 13, 2021 8:05 AM SENSOR OUT ALARM 3 DISP 5-6 JUL 24, 2023 2:05 PM FUEL ALARM JUL 24, 2023 2:05 PM LOW LIQUID ALARM 4 DISP 7-8 JUL 24, 2023 2:06 PM FUEL ALARM JUL 24, 2023 2:05 PM LOW LIQUID ALARM FEB 13, 2021 8:05 AM SENSOR OUT ALARM 5 DISP 9-10 JUL 24, 2023 2:04 PM FUEL ALARM JUL 24, 2023 2:03 PM LOW LIQUID ALARM FEB 13, 2021 8:05 AM SENSOR OUT ALARM 6 DISP 11-12 JUL 24, 2023 2:05 PM FUEL ALARM JUL 24, 2023 2:04 PM LOW LIQUID ALARM FEB 13, 2021 8:05 AM SENSOR OUT ALARM 7 UNL STP JUL 24, 2023 1:54 PM FUEL ALARM JUL 24, 2023 1:52 PM LOW LIQUID ALARM 8 UNL FILL APR 1, 2024 9:12 AM FUEL ALARM MAR 11, 2024 5:59 PM FUEL ALARM JUL 24, 2023 2:17 PM LOW LIQUID ALARM 9 SUPREME STP JUN 7, 2024 2:44 AM FUEL ALARM MAY 20, 2024 8:16 AM LOW LIQUID ALARM MAY 17, 2024 2:11 PM LOW LIQUID ALARM 10 SUPREME FILL MAY 20, 2024 8:14 AM SENSOR OUT ALARM MAY 20, 2024 8:06 AM LOW LIQUID ALARM MAY 20, 2024 8:06 AM FUEL ALARM 11 DIESEL STP JUL 24, 2023 1:51 PM LOW LIQUID ALARM JUL 24, 2023 1:51 PM FUEL ALARM FEB 13, 2021 8:05 AM SENSOR OUT ALARM 12 DIESEL FILL JUL 24, 2023 2:15 PM FUEL ALARM JUL 24, 2023 2:12 PM FUEL ALARM JUL 24, 2023 2:12 PM LOW LIQUID ALARM 13 VENT BOX NOV 26, 2023 3:37 AM LOW LIQUID ALARM NOV 25, 2023 6:13 AM LOW LIQUID ALARM JUL 24, 2023 2:12 PM FUEL ALARM I31600 JUN 19, 2024 8:50 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 FM 2 DISP 3-4 FM 3 DISP 5-6 FM 4 DISP 7-8 FM 5 DISP 9-10 FM 6 DISP 11-12 FM 7 DISP 5-6 PS 8 ATM 9 UNL TANK JUL 24, 2023 1:56 PM NO VACUUM ALARM 10 UNL PRODUCT JUL 24, 2023 1:56 PM HIGH LIQUID ALARM JUL 24, 2023 1:56 PM NO VACUUM ALARM JUL 24, 2023 1:55 PM NO VACUUM ALARM 11 VAPOR RETURN AUG 11, 2023 7:15 AM HIGH LIQUID ALARM AUG 11, 2023 5:49 AM HIGH LIQUID ALARM AUG 11, 2023 5:48 AM HIGH LIQUID ALARM 12 SUPREME TANK JUL 24, 2023 1:55 PM NO VACUUM ALARM 13 SUPREME PRODUCT JUL 24, 2023 2:08 PM HIGH LIQUID ALARM JUL 24, 2023 1:56 PM NO VACUUM ALARM 14 UNL-SUP VENT JUL 24, 2023 2:08 PM HIGH LIQUID ALARM JUL 24, 2023 1:56 PM HIGH LIQUID ALARM JUL 24, 2023 1:56 PM NO VACUUM ALARM 15 DIESEL TANK SEP 25, 2023 11:50 AM NO VACUUM ALARM SEP 25, 2023 11:46 AM NO VACUUM ALARM SEP 25, 2023 11:45 AM NO VACUUM ALARM 16 DIESEL PRODUCT JUL 24, 2023 1:53 PM HIGH LIQUID ALARM JUL 24, 2023 1:53 PM NO VACUUM ALARM 17 DIESEL VENT JUL 24, 2023 1:53 PM HIGH LIQUID ALARM JUL 24, 2023 1:53 PM NO VACUUM ALARM I40200 JUN 19, 2024 8:50 AM I40300 JUN 19, 2024 8:50 AM I34200 JUN 19, 2024 8:50 AM I34700 JUN 19, 2024 8:50 AM IV0100 JUN 19, 2024 8:50 AM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 97% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-06 10:08:04 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 0.59 24-05-17 10:06:44 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 0.60 24-01-25 10:03:54 SENSOR OUT SELFTEST E 1 23-12-08 10:03:55 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 0.60 23-11-12 10:03:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 23-11-11 10:03:26 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 23-11-10 10:03:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 23-11-09 10:04:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.20 23-10-30 10:01:14 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 104.90 23-10-29 10:01:10 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 106.07 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-12-09 10:03:46 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 23-10-31 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 104.56 22-10-09 10:03:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 43.37 22-10-08 10:03:42 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.44 22-10-07 10:03:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.38 22-06-11 10:07:00 FLOW PERFORMANCE HOSE BLOCKAGE FP 7 BLEND3 22-03-05 10:07:15 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 21-09-07 10:07:55 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-08-18 10:08:51 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-07-26 10:05:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 5 BLEND3 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 24-06-18 10:06:53 READINESS ISD:PP EVR:PP ISD & EVR READY 24-06-17 16:21:31 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-06-17 16:21:31 ISD STARTUP 24-06-17 15:47:10 ISD SHUTDOWN 24-06-07 10:59:05 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 24-06-07 08:14:35 COLLECTION TEST HH12 GRADE TEST MANUALLY CLEARED 24-05-17 14:15:48 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 24-05-12 10:06:01 READINESS ISD:PP EVR:PP ISD & EVR READY 24-05-11 16:28:55 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-05-11 16:28:55 ISD STARTUP Post Alarm History Responses Received: I10200 JUN 19, 2024 2:40 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164126 163649 2 7SMARTSENSOR BD 505360 504405 3 8SMARTSENSOR BD 39330 39266 4 8SMARTSENSOR BD 39396 39310 5 INTERSTITIAL BD 201541 201244 6 INTERSTITIAL BD 201257 200818 7 UNUSED 4846706 4817162 8 UNUSED 4839908 4808523 9 RELAY BOARD 14963 14955 10 STP SENSE BOARD 33096 33067 11 UNUSED 4852892 4809305 12 UNUSED 4850212 4812010 13 UNUSED 4844743 4811617 14 UNUSED 4843327 4810047 15 UNUSED 4848970 4803328 16 UNUSED 4850147 4806404 COMM 1 ELEC DISP INT. 101203 101385 COMM 2 RS232 SERIAL BD 14897 14889 COMM 3 SERIAL SAT BD 480489 480315 COMM 4 UNUSED 4852979 4809131 COMM 5 UNUSED 4849885 4810178 COMM 6 UNUSED 4842259 4815348 I90200 JUN 19, 2024 2:40 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUN 19, 2024 2:40 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME s15 OTHER DIESEL TANK NO VACUUM ALARM CLEAR 6-19-24 12:23PM s12 OTHER SUPREME TANK NO VACUUM ALARM CLEAR 6-19-24 12:18PM s 9 OTHER UNL TANK NO VACUUM ALARM CLEAR 6-19-24 12:11PM L 3 DISP PAN DISP 5-6 LOW LIQUID ALARM CLEAR 6-19-24 11:39AM L 3 DISP PAN DISP 5-6 LOW LIQUID ALARM ALARM 6-19-24 11:39AM L 4 DISP PAN DISP 7-8 LOW LIQUID ALARM CLEAR 6-19-24 11:38AM L 4 DISP PAN DISP 7-8 LOW LIQUID ALARM ALARM 6-19-24 11:38AM L 2 DISP PAN DISP 3-4 LOW LIQUID ALARM CLEAR 6-19-24 11:38AM L 2 DISP PAN DISP 3-4 LOW LIQUID ALARM ALARM 6-19-24 11:37AM L13 OTHER VENT BOX LOW LIQUID ALARM CLEAR 6-19-24 11:07AM L13 OTHER VENT BOX LOW LIQUID ALARM ALARM 6-19-24 11:07AM L13 OTHER VENT BOX LOW LIQUID ALARM CLEAR 6-19-24 11:06AM L13 OTHER VENT BOX LOW LIQUID ALARM ALARM 6-19-24 11:06AM L13 OTHER VENT BOX FUEL ALARM CLEAR 6-19-24 11:06AM L13 OTHER VENT BOX FUEL ALARM ALARM 6-19-24 11:06AM L 6 DISP PAN DISP 11-12 FUEL ALARM CLEAR 6-19-24 10:59AM L 6 DISP PAN DISP 11-12 FUEL ALARM ALARM 6-19-24 10:56AM L11 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L10 OTHER SUPREME FILL SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L12 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 9 STP SUMP SUPREME STP SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L13 OTHER VENT BOX SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 2 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 3 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 7 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 6 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 8 OTHER UNL FILL SENSOR OUT ALARM CLEAR 6-19-24 10:25AM L 7 STP SUMP UNL STP SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 4 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 3 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 2 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 1 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 6 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 8 OTHER UNL FILL SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 5 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 6-19-24 10:24AM L10 OTHER SUPREME FILL SENSOR OUT ALARM ALARM 6-19-24 10:24AM L12 OTHER DIESEL FILL SENSOR OUT ALARM ALARM 6-19-24 10:24AM L11 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 6-19-24 10:24AM L 9 STP SUMP SUPREME STP SENSOR OUT ALARM ALARM 6-19-24 10:24AM L13 OTHER VENT BOX SENSOR OUT ALARM ALARM 6-19-24 10:24AM s 9 OTHER UNL TANK NO VACUUM ALARM ALARM 6-19-24 10:17AM s 9 OTHER UNL TANK HIGH LIQUID ALARM CLEAR 6-19-24 10:16AM s 9 OTHER UNL TANK HIGH LIQUID ALARM ALARM 6-19-24 10:15AM s12 OTHER SUPREME TANK HIGH LIQUID ALARM CLEAR 6-19-24 10:11AM s12 OTHER SUPREME TANK HIGH LIQUID ALARM ALARM 6-19-24 10:10AM s12 OTHER SUPREME TANK NO VACUUM ALARM ALARM 6-19-24 10:10AM s15 OTHER DIESEL TANK HIGH LIQUID ALARM CLEAR 6-19-24 10:05AM I11200 JUN 19, 2024 2:40 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h11 OTHER FP11: BLEND3 FLOW COLLECT WARN ALARM 6-19-24 10:06AM SYSTEM PRINTER ERROR CLEAR 6-19-24 9:22AM SYSTEM PAPER OUT CLEAR 6-19-24 9:21AM SYSTEM PAPER OUT ALARM 6-19-24 9:21AM SYSTEM PAPER OUT CLEAR 6-19-24 9:21AM SYSTEM PAPER OUT ALARM 6-19-24 9:21AM SYSTEM PAPER OUT CLEAR 6-19-24 9:21AM SYSTEM PAPER OUT ALARM 6-19-24 9:21AM SYSTEM PAPER OUT CLEAR 6-19-24 9:21AM SYSTEM PAPER OUT ALARM 6-19-24 9:21AM SYSTEM PRINTER ERROR ALARM 6-19-24 9:21AM h12 OTHER FP12: BLEND3 FLOW COLLECT WARN CLEAR 6-07-24 8:14AM h12 OTHER FP12: BLEND3 FLOW COLLECT WARN ALARM 6-06-24 10:08AM SYSTEM PRINTER ERROR CLEAR 5-28-24 8:00AM SYSTEM PAPER OUT CLEAR 5-28-24 8:00AM SYSTEM PRINTER ERROR ALARM 5-28-24 8:00AM SYSTEM PAPER OUT ALARM 5-28-24 8:00AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN CLEAR 5-17-24 2:15PM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN ALARM 5-17-24 10:06AM SYSTEM PRINTER ERROR CLEAR 5-08-24 1:03AM SYSTEM PAPER OUT CLEAR 5-08-24 1:03AM SYSTEM PAPER OUT ALARM 5-08-24 1:03AM SYSTEM PRINTER ERROR ALARM 5-08-24 1:03AM SYSTEM PRINTER ERROR CLEAR 5-08-24 1:02AM SYSTEM PAPER OUT CLEAR 5-08-24 1:02AM SYSTEM PRINTER ERROR ALARM 5-08-24 1:02AM SYSTEM PRINTER ERROR CLEAR 5-08-24 1:02AM SYSTEM PRINTER ERROR ALARM 5-08-24 1:01AM SYSTEM PAPER OUT ALARM 5-08-24 1:00AM SYSTEM PRINTER ERROR CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT ALARM 4-17-24 11:49PM SYSTEM PRINTER ERROR ALARM 4-17-24 11:49PM SYSTEM PRINTER ERROR CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT CLEAR 4-17-24 11:49PM SYSTEM PAPER OUT ALARM 4-17-24 11:49PM SYSTEM PAPER OUT CLEAR 4-17-24 11:49PM SYSTEM PRINTER ERROR ALARM 4-17-24 11:48PM SYSTEM PAPER OUT ALARM 4-17-24 11:48PM SYSTEM PRINTER ERROR CLEAR 4-11-24 2:27PM SYSTEM PAPER OUT CLEAR 4-11-24 2:26PM SYSTEM PRINTER ERROR ALARM 4-11-24 2:26PM SYSTEM PAPER OUT ALARM 4-11-24 2:22PM SYSTEM PRINTER ERROR CLEAR 3-23-24 12:24AM SYSTEM PAPER OUT CLEAR 3-23-24 12:24AM SYSTEM PAPER OUT ALARM 3-23-24 12:24AM SYSTEM PRINTER ERROR ALARM 3-23-24 12:24AM SYSTEM PRINTER ERROR CLEAR 3-03-24 4:27AM SYSTEM PRINTER ERROR ALARM 3-03-24 4:27AM SYSTEM PAPER OUT CLEAR 3-03-24 4:27AM I20600 JUN 19, 2024 2:40 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 SUPREME TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUN 19, 2024 2:41 PM I30200 JUN 19, 2024 2:41 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:45 AM LOW LIQUID ALARM JUN 19, 2024 9:44 AM FUEL ALARM 2 DISP 3-4 JUN 19, 2024 11:37 AM LOW LIQUID ALARM JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:44 AM LOW LIQUID ALARM 3 DISP 5-6 JUN 19, 2024 11:39 AM LOW LIQUID ALARM JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:42 AM LOW LIQUID ALARM 4 DISP 7-8 JUN 19, 2024 11:38 AM LOW LIQUID ALARM JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:42 AM LOW LIQUID ALARM 5 DISP 9-10 JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:41 AM LOW LIQUID ALARM JUN 19, 2024 9:40 AM FUEL ALARM 6 DISP 11-12 JUN 19, 2024 10:56 AM FUEL ALARM JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:39 AM LOW LIQUID ALARM 7 UNL STP JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:31 AM LOW LIQUID ALARM JUN 19, 2024 9:30 AM LOW LIQUID ALARM 8 UNL FILL JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:34 AM LOW LIQUID ALARM JUN 19, 2024 9:34 AM FUEL ALARM 9 SUPREME STP JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:27 AM LOW LIQUID ALARM JUN 19, 2024 9:27 AM FUEL ALARM 10 SUPREME FILL JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:36 AM LOW LIQUID ALARM JUN 19, 2024 9:35 AM FUEL ALARM 11 DIESEL STP JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:26 AM LOW LIQUID ALARM JUN 19, 2024 9:25 AM FUEL ALARM 12 DIESEL FILL JUN 19, 2024 10:24 AM SENSOR OUT ALARM JUN 19, 2024 9:37 AM LOW LIQUID ALARM JUN 19, 2024 9:36 AM FUEL ALARM 13 VENT BOX JUN 19, 2024 11:07 AM LOW LIQUID ALARM JUN 19, 2024 11:06 AM LOW LIQUID ALARM JUN 19, 2024 11:06 AM FUEL ALARM I31600 JUN 19, 2024 2:41 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 FM 2 DISP 3-4 FM 3 DISP 5-6 FM 4 DISP 7-8 FM 5 DISP 9-10 FM 6 DISP 11-12 FM 7 DISP 5-6 PS 8 ATM 9 UNL TANK JUN 19, 2024 10:17 AM NO VACUUM ALARM JUN 19, 2024 10:15 AM HIGH LIQUID ALARM JUL 24, 2023 1:56 PM NO VACUUM ALARM 10 UNL PRODUCT JUN 19, 2024 9:52 AM NO VACUUM ALARM JUN 19, 2024 9:51 AM HIGH LIQUID ALARM JUL 24, 2023 1:56 PM HIGH LIQUID ALARM 11 VAPOR RETURN JUN 19, 2024 9:53 AM NO VACUUM ALARM JUN 19, 2024 9:51 AM HIGH LIQUID ALARM AUG 11, 2023 7:15 AM HIGH LIQUID ALARM 12 SUPREME TANK JUN 19, 2024 10:10 AM HIGH LIQUID ALARM JUN 19, 2024 10:10 AM NO VACUUM ALARM JUL 24, 2023 1:55 PM NO VACUUM ALARM 13 SUPREME PRODUCT JUN 19, 2024 9:48 AM NO VACUUM ALARM JUN 19, 2024 9:48 AM HIGH LIQUID ALARM JUL 24, 2023 2:08 PM HIGH LIQUID ALARM 14 UNL-SUP VENT JUN 19, 2024 9:49 AM NO VACUUM ALARM JUN 19, 2024 9:48 AM HIGH LIQUID ALARM JUL 24, 2023 2:08 PM HIGH LIQUID ALARM 15 DIESEL TANK JUN 19, 2024 10:04 AM HIGH LIQUID ALARM JUN 19, 2024 9:54 AM NO VACUUM ALARM SEP 25, 2023 11:50 AM NO VACUUM ALARM 16 DIESEL PRODUCT JUN 19, 2024 9:54 AM NO VACUUM ALARM JUN 19, 2024 9:52 AM HIGH LIQUID ALARM JUL 24, 2023 1:53 PM HIGH LIQUID ALARM 17 DIESEL VENT JUN 19, 2024 9:53 AM NO VACUUM ALARM JUN 19, 2024 9:52 AM HIGH LIQUID ALARM JUL 24, 2023 1:53 PM HIGH LIQUID ALARM I40200 JUN 19, 2024 2:41 PM I40300 JUN 19, 2024 2:41 PM I34200 JUN 19, 2024 2:41 PM I34700 JUN 19, 2024 2:41 PM IV0100 JUN 19, 2024 2:41 PM 175900 MESA MARIN CH PIT STOP MARKET 11101 HWY. 178 BAKERSFIELD,CA 93306 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :WARN EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-19 10:06:10 FLOW PERFORMANCE HOSE BLOCKAGE FP11 BLEND3 0.57 24-06-06 10:08:04 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 0.59 24-05-17 10:06:44 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 0.60 24-01-25 10:03:54 SENSOR OUT SELFTEST E 1 23-12-08 10:03:55 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 0.60 23-11-12 10:03:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 23-11-11 10:03:26 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 23-11-10 10:03:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 23-11-09 10:04:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.20 23-10-30 10:01:14 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 104.90 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 23-12-09 10:03:46 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 23-10-31 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 104.56 22-10-09 10:03:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 43.37 22-10-08 10:03:42 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.44 22-10-07 10:03:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 39.38 22-06-11 10:07:00 FLOW PERFORMANCE HOSE BLOCKAGE FP 7 BLEND3 22-03-05 10:07:15 FLOW PERFORMANCE HOSE BLOCKAGE FP 1 BLEND3 21-09-07 10:07:55 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-08-18 10:08:51 FLOW PERFORMANCE HOSE BLOCKAGE FP12 BLEND3 21-07-26 10:05:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 5 BLEND3 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 24-06-19 10:27:32 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-06-19 10:27:32 ISD STARTUP 24-06-19 10:27:27 ISD SHUTDOWN 24-06-18 10:06:53 READINESS ISD:PP EVR:PP ISD & EVR READY 24-06-17 16:21:31 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-06-17 16:21:31 ISD STARTUP 24-06-17 15:47:10 ISD SHUTDOWN 24-06-07 10:59:05 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 24-06-07 08:14:35 COLLECTION TEST HH12 GRADE TEST MANUALLY CLEARED 24-05-17 14:15:48 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED