Loading...
HomeMy WebLinkAboutFMC 2024Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10157583 06/25/2024 Avo Shell 5700 Auburn Street Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 VeederRoot TLS-3XX Technician - C32655 10/11/2024 Vaporless Manufacturing Inc. - #5265 10/21/2024 OPW - 1193585 04/14/2025 06/25/2024 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 303 87 Unleaded Tank ANN L2 303 91 Premium Tank ANN L3 303 Diesel Tank ANN L9 208 Diesel STP L10 208 Diesel STP ANN L11 208 87 Unleaded Fill L12 304 87 Unleaded Fill L13 304 91 Premium Fill ANN L14 208 91 Premium Fill L15 208 Diesel Fill L16 304 Diesel Fill ANN L17 208 Dispenser 9-10 UDC L18 304 Dispenser 9-10 UDC ANN L19 208 Dispenser 11-12 UDC L20 304 Dispenser 11-12 UDC ANN L21 208 87 Unleaded STP L22 304 87 Unleaded STP ANN L23 208 91 Premium STP L24 304 91 Premium STP ANN L25 208 Dispenser 1-2 UDC L26 303 Dispenser 1-2 UDC ANN L27 208 Dispenser 3-4 UDC L28 304 Dispenser 3-4 UDC ANN L29 208 Dispenser 5-6 UDC Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L30 304 Dispenser 5-6 UDC ANN L31 208 Dispenser 7-8 UDC L32 304 Dispenser 7-8 UDC ANN S8 363/364 87 Product S9 363/364 91 Vent S10 363/364 87-91 Vapor S11 363/364 87 Vent S12 363/364 91 Product S14 363/364 Diesel Product S15 363/364 Diesel Vent Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 Unleaded T2 FX1V 91 Premium T3 FX1DV Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Emergency Shutoff Switch - when compressed kills power to STPs, Dispensers, as well as VeederRoot and Point-Of-Sale. When testing the ESO, a power breaker switch labeled "Panel FC" must be reset in order to restore power to all applications. Reset switches and breakers are located in the back room of the building. All electrical site components and breaker panels are located in said room. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Avo Shell5700 Auburn StreetBakersfield10157583Disp 3-4Disp 7-8 Disp 11-12MPDMPDMPDMPDMPDMPDDisp 1-2Disp 5-6Disp 9-10ProductProductProductProductProductProductBrandon Nunez Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10157583 06/25/2024 Avo Shell 5700 Auburn Street Bakersfield 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 OPW - 1193585 04/14/2025 PEI 1200 1 Hour Hydrostatic All Spill Containers 06/25/2024 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1: 87 UNL OPW T2: 91 PNL OPW T3: DSL OPW Avo Shell System Setup & Alarm History Responses Received: 200 FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 06-25-24 2:23 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 9657 57.50 0.0 88.2 10046 2 PREMIUM 4604 37.48 0.0 84.9 6923 3 DIESEL 4464 36.62 0.0 89.0 7063 I90500 06-25-24 2:23 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 06-25-24 2:23 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MM-DD-YY HH:MM:SS xM I50201 06-25-24 2:23 PM SHIFT TIME 1 : 6:00 AM I50202 06-25-24 2:23 PM SHIFT TIME 2 : DISABLED I50203 06-25-24 2:23 PM SHIFT TIME 3 : DISABLED I50204 06-25-24 2:23 PM SHIFT TIME 4 : DISABLED I54600 06-25-24 2:23 PM TANK PER TST NEEDED WRN: DISABLED I54900 06-25-24 2:23 PM TANK ANN TST NEEDED WRN: DISABLED I55300 06-25-24 2:23 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 06-25-24 2:23 PM LINE PER TST NEEDED WRN: DISABLED I55900 06-25-24 2:23 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 06-25-24 2:23 PM PRINT TC VOLUMES ENABLED I50E00 06-25-24 2:23 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 06-25-24 2:23 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 06-25-24 2:23 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 06-25-24 2:23 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 06-25-24 2:23 PM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 06-25-24 2:23 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 06-25-24 2:23 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 06-25-24 2:23 PM TANK CHART SECURITY DISABLED I5BD00 06-25-24 2:23 PM CUSTOM ALARM LABELS DISABLED I56000 06-25-24 2:23 PM MASS/DENSITY DISABLED I88101 06-25-24 2:23 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 06-25-24 2:23 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 06-25-24 2:23 PM I88104 06-25-24 2:23 PM I88105 06-25-24 2:23 PM I88106 06-25-24 2:23 PM I52000 06-25-24 2:23 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAR 11, 2012 DISABLED 2 ON DATE MAR 11, 2012 DISABLED 3 ON DATE MAR 11, 2012 DISABLED 4 ON DATE MAR 11, 2012 DISABLED 5 ON DATE MAR 11, 2012 DISABLED 6 ON DATE MAR 11, 2012 DISABLED 7 ON DATE MAR 11, 2012 DISABLED 8 ON DATE MAR 11, 2012 DISABLED I60100 06-25-24 2:23 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 06-25-24 2:23 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 06-25-24 2:23 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 06-25-24 2:23 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 06-25-24 2:23 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 117.75 2 PREMIUM 89.75 3 DIESEL 89.75 4 0.00 I60A00 06-25-24 2:23 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 4 PTS 19703 2 PREMIUM 4 PTS 11527 3 DIESEL 4 PTS 11527 4 1 PT 0 I60400 06-25-24 2:23 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 2 PREMIUM 11527 3 DIESEL 11527 4 0 I60500 06-25-24 2:23 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 16062 9961 3824 2 PREMIUM 11527 9379 5836 2271 3 DIESEL 11527 9379 5836 2271 4 0 0 0 0 I60600 06-25-24 2:23 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 0 0 0 0 16062 0 0 0 0 9961 0 0 0 0 3824 0 0 0 0 2 PREMIUM 11527 0 0 0 0 9379 0 0 0 0 5836 0 0 0 0 2271 0 0 0 0 3 DIESEL 11527 0 0 0 0 9379 0 0 0 0 5836 0 0 0 0 2271 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 06-25-24 2:23 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 06-25-24 2:23 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 3.0 IN. 2 PREMIUM 3.0 IN. 3 DIESEL 3.0 IN. I62700 06-25-24 2:23 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 I64200 06-25-24 2:23 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 PREMIUM LOW 3 DIESEL LOW I62400 06-25-24 2:23 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 06-25-24 2:23 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 2 PREMIUM 11527 3 DIESEL 11527 4 0 I62300 06-25-24 2:23 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 18718 2 PREMIUM 10374 3 DIESEL 10374 4 0 I62200 06-25-24 2:23 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 18718 2 PREMIUM 10951 3 DIESEL 10951 4 0 I62900 06-25-24 2:23 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62100 06-25-24 2:23 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1500 2 PREMIUM 1000 3 DIESEL 1000 4 0 I62600 06-25-24 2:23 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 06-25-24 2:23 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 50 2 PREMIUM 50 3 DIESEL 50 4 99 I60800 06-25-24 2:23 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I60B00 06-25-24 2:23 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 06-25-24 2:23 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 06-25-24 2:23 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 06-25-24 2:23 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62A00 06-25-24 2:23 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62C00 06-25-24 2:23 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 06-25-24 2:23 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 06-25-24 2:23 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 06-25-24 2:23 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 06-25-24 2:23 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 06-25-24 2:23 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63A00 06-25-24 2:23 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 06-25-24 2:24 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ANNUALLY: ALL TANK DEC WEEK 1 SUN START TIME : 2:30 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 06-25-24 2:24 PM CSLD PROBABLITY OF DETECTION I61400 06-25-24 2:24 PM CSLD CLIMATE FACTOR I61600 06-25-24 2:24 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 06-25-24 2:24 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 06-25-24 2:24 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 06-25-24 2:24 PM CSLD REPORT ONLY I62B00 06-25-24 2:24 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 00-00-00 2 PREMIUM 00-00-00 3 DIESEL 00-00-00 4 00-00-00 I63300 06-25-24 2:24 PM LEAK TEST REPORT FORMAT: NORMAL I63400 06-25-24 2:24 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 06-25-24 2:24 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 06-25-24 2:24 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 06-25-24 2:24 PM I77700 06-25-24 2:24 PM I77800 06-25-24 2:24 PM I78C00 06-25-24 2:24 PM I78300 06-25-24 2:24 PM I78F00 06-25-24 2:24 PM I78700 06-25-24 2:24 PM I70200 06-25-24 2:24 PM LIQUID LABEL DEVICE LABEL 1 UNL TANK ANN 2 PREM TANK ANN 3 DIESEL TANK ANN 4 5 6 7 8 9 DIESEL STP 10 DIESEL STP ANN 11 UNL FILL 12 UNL FILL ANN 13 PREM FILL ANN 14 PREM FILL 15 DIESEL FILL 16 DIESEL FILL ANN 17 DIS 9-10 18 DIS 9-10 ANN 19 DIS 11-12 20 DIS 11-12 ANN 21 UNL STP 22 UNL STP ANN 23 PREM STP 24 PREM STP ANN 25 DIS 1-2 26 DIS 1-2 ANN 27 DIS 3-4 28 DIS 3-4 ANN 29 DIS 5-6 30 DIS 5-6 ANN 31 DIS 7-8 32 DIS 7-8 ANN I70300 06-25-24 2:24 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL TANK ANN DUAL POINT HYDROSTATIC 2 PREM TANK ANN DUAL POINT HYDROSTATIC 3 DIESEL TANK ANN DUAL POINT HYDROSTATIC 4 TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DIESEL STP TRI-STATE (SINGLE FLOAT) 10 DIESEL STP ANN TRI-STATE (SINGLE FLOAT) 11 UNL FILL TRI-STATE (SINGLE FLOAT) 12 UNL FILL ANN TRI-STATE (SINGLE FLOAT) 13 PREM FILL ANN TRI-STATE (SINGLE FLOAT) 14 PREM FILL TRI-STATE (SINGLE FLOAT) 15 DIESEL FILL TRI-STATE (SINGLE FLOAT) 16 DIESEL FILL ANN TRI-STATE (SINGLE FLOAT) 17 DIS 9-10 TRI-STATE (SINGLE FLOAT) 18 DIS 9-10 ANN TRI-STATE (SINGLE FLOAT) 19 DIS 11-12 TRI-STATE (SINGLE FLOAT) 20 DIS 11-12 ANN TRI-STATE (SINGLE FLOAT) 21 UNL STP TRI-STATE (SINGLE FLOAT) 22 UNL STP ANN TRI-STATE (SINGLE FLOAT) 23 PREM STP TRI-STATE (SINGLE FLOAT) 24 PREM STP ANN TRI-STATE (SINGLE FLOAT) 25 DIS 1-2 TRI-STATE (SINGLE FLOAT) 26 DIS 1-2 ANN TRI-STATE (SINGLE FLOAT) 27 DIS 3-4 TRI-STATE (SINGLE FLOAT) 28 DIS 3-4 ANN TRI-STATE (SINGLE FLOAT) 29 DIS 5-6 TRI-STATE (SINGLE FLOAT) 30 DIS 5-6 ANN TRI-STATE (SINGLE FLOAT) 31 DIS 7-8 TRI-STATE (SINGLE FLOAT) 32 DIS 7-8 ANN TRI-STATE (SINGLE FLOAT) I70400 06-25-24 2:24 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL TANK ANN ANNULAR SPACE 2 PREM TANK ANN ANNULAR SPACE 3 DIESEL TANK ANN ANNULAR SPACE 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS 9 DIESEL STP STP SUMP 10 DIESEL STP ANN ANNULAR SPACE 11 UNL FILL PIPING SUMP 12 UNL FILL ANN ANNULAR SPACE 13 PREM FILL ANN ANNULAR SPACE 14 PREM FILL PIPING SUMP 15 DIESEL FILL PIPING SUMP 16 DIESEL FILL ANN ANNULAR SPACE 17 DIS 9-10 DISPENSER PAN 18 DIS 9-10 ANN ANNULAR SPACE 19 DIS 11-12 DISPENSER PAN 20 DIS 11-12 ANN ANNULAR SPACE 21 UNL STP STP SUMP 22 UNL STP ANN ANNULAR SPACE 23 PREM STP STP SUMP 24 PREM STP ANN ANNULAR SPACE 25 DIS 1-2 DISPENSER PAN 26 DIS 1-2 ANN ANNULAR SPACE 27 DIS 3-4 DISPENSER PAN 28 DIS 3-4 ANN ANNULAR SPACE 29 DIS 5-6 DISPENSER PAN 30 DIS 5-6 ANN ANNULAR SPACE 31 DIS 7-8 DISPENSER PAN 32 DIS 7-8 ANN ANNULAR SPACE I74200 06-25-24 2:24 PM I74300 06-25-24 2:24 PM I74400 06-25-24 2:24 PM I74700 06-25-24 2:24 PM I74800 06-25-24 2:24 PM I74900 06-25-24 2:24 PM I7BC00 06-25-24 2:24 PM I80200 06-25-24 2:24 PM I80300 06-25-24 2:24 PM I80400 06-25-24 2:24 PM I80700 06-25-24 2:24 PM RELAY LABEL DEVICE LABEL 1 87 STP 2 91 STP 3 DIESEL STP 4 OVERFILL ALARM I80900 06-25-24 2:24 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 STP NORMALLY OPEN 2 91 STP NORMALLY OPEN 3 DIESEL STP NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN I80B00 06-25-24 2:24 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 STP 1 2 91 STP 2 3 DIESEL STP 3 4 OVERFILL ALARM NONE I80A00 06-25-24 2:24 PM RELAY TYPE RELAY DESIGNATION TYPE 1 87 STP PUMP CONTROL OUTPUT 2 91 STP PUMP CONTROL OUTPUT 3 DIESEL STP PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD I80C00 06-25-24 2:24 PM I80800 06-25-24 2:24 PM RELAY SETUP REPORT R 1:87 STP TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L29:FUEL ALARM L31:FUEL ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM L29:SENSOR OUT ALARM L31:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 2:91 STP TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L17:FUEL ALARM L19:FUEL ALARM L23:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L29:FUEL ALARM L31:FUEL ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L23:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM L29:SENSOR OUT ALARM L31:SENSOR OUT ALARM L17:SHORT ALARM L19:SHORT ALARM L23:SHORT ALARM L25:SHORT ALARM L27:SHORT ALARM L29:SHORT ALARM L31:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 3:DIESEL STP TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L 9:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM I79000 06-25-24 2:25 PM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 06-25-24 2:25 PM I72300 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PRESS DISP 1-2 VAPOR PRESSURE 02 FM DISP 1-2 AIR FLOW METER 03 FM DISP 3-4 AIR FLOW METER 04 FM DISP 5-6 AIR FLOW METER 05 FM DISP 7-8 AIR FLOW METER 06 FM DISP 9-10 AIR FLOW METER 07 FM DISP 11-12 AIR FLOW METER 08 87 PROD VAC SENSOR 09 91 VENT VAC SENSOR 10 87-91 VAPOR VAC SENSOR 11 87 VENT VAC SENSOR 12 91 PROD VAC SENSOR 13 91 VENT VAC SENSOR 14 DIESEL PROD VAC SENSOR 15 DIESEL VENT VAC SENSOR 16 ATM PRESS ATM P SENSOR 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 VAPOR PROCESSOR TYPE NONE IV4700 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ACCEPT HIGH ORVR: YES IV4A00 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 01/01 09/01 xx/xx 02 01 02/02 01/02 09/02 xx/xx 03 02 02/03 01/03 09/03 xx/xx 04 02 02/04 01/04 09/04 xx/xx 05 03 02/05 01/05 09/05 xx/xx 06 03 02/06 01/06 09/06 xx/xx 07 04 02/07 01/07 09/07 xx/xx 08 04 02/08 01/08 09/08 xx/xx 09 05 02/09 01/09 09/09 xx/xx 16 05 02/10 01/10 09/10 xx/xx 17 06 02/11 01/11 09/11 xx/xx 18 06 02/12 01/12 09/12 xx/xx IV4900 06-25-24 2:25 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 06-25-24 2:25 PM ISD VERSION: 01.07 Pre Alarm History Responses Received: I10200 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39536 39433 2 7SMARTSENSOR BD 507076 505098 3 UNUSED 4977997 4977679 4 4 PROBE / G.T. 162746 162696 5 INTERSTITIAL BD 201384 201059 6 INTERSTITIAL BD 201595 201229 7 INTERSTITIAL BD 201173 200930 8 INTERSTITIAL BD 201363 200973 9 RELAY BOARD 14935 14941 10 STP SENSE BOARD 33180 33147 11 UNUSED 4980403 4975840 12 UNUSED 4974185 4974321 13 UNUSED 4972177 4975426 14 UNUSED 4970890 4973354 15 UNUSED 4969838 4973019 16 UNUSED 4973444 4970770 COMM 1 ELEC DISP INT. 101010 100907 COMM 2 RS232 SERIAL BD 14955 14961 COMM 3 UNUSED 4975744 4974597 COMM 4 UNUSED 4973580 4970514 COMM 5 UNUSED 4969584 4969784 COMM 6 UNUSED 4969467 4974716 I90200 06-25-24 2:26 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME E 1 OTHER COMMUNICATION ALARM CLEAR 06-24-24 2:07 AM E 1 OTHER COMMUNICATION ALARM ALARM 06-24-24 2:07 AM E 1 OTHER COMMUNICATION ALARM CLEAR 06-17-24 2:07 AM E 1 OTHER COMMUNICATION ALARM ALARM 06-17-24 2:07 AM E 1 OTHER COMMUNICATION ALARM CLEAR 06-07-24 9:38 PM E 1 OTHER COMMUNICATION ALARM ALARM 06-07-24 9:38 PM E 1 OTHER COMMUNICATION ALARM CLEAR 06-07-24 6:40 AM E 1 OTHER COMMUNICATION ALARM ALARM 06-07-24 6:40 AM E 1 OTHER COMMUNICATION ALARM CLEAR 06-03-24 2:07 AM E 1 OTHER COMMUNICATION ALARM ALARM 06-03-24 2:07 AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT FAIL CLEAR 06-02-24 10:19 AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT FAIL ALARM 06-02-24 10:03 AM E 1 OTHER COMMUNICATION ALARM CLEAR 05-27-24 2:08 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-27-24 2:08 AM L14 PIPE PREM FILL FUEL ALARM CLEAR 05-24-24 11:40 AM L14 PIPE PREM FILL FUEL ALARM ALARM 05-24-24 11:39 AM L14 PIPE PREM FILL FUEL ALARM CLEAR 05-24-24 11:39 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT FAIL CLEAR 05-24-24 10:08 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT FAIL ALARM 05-24-24 10:03 AM L14 PIPE PREM FILL FUEL ALARM ALARM 05-23-24 4:48 PM E 1 OTHER COMMUNICATION ALARM CLEAR 05-20-24 2:07 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-20-24 2:07 AM E 1 OTHER COMMUNICATION ALARM CLEAR 05-05-24 12:27 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-05-24 12:27 AM E 1 OTHER COMMUNICATION ALARM CLEAR 05-04-24 10:32 PM E 1 OTHER COMMUNICATION ALARM ALARM 05-04-24 10:32 PM E 1 OTHER COMMUNICATION ALARM CLEAR 05-04-24 9:50 PM E 1 OTHER COMMUNICATION ALARM ALARM 05-04-24 9:50 PM E 1 OTHER COMMUNICATION ALARM CLEAR 04-29-24 2:07 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-29-24 2:07 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-28-24 12:37 PM E 1 OTHER COMMUNICATION ALARM ALARM 04-28-24 12:37 PM E 1 OTHER COMMUNICATION ALARM CLEAR 04-28-24 6:48 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-28-24 6:48 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-28-24 6:36 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-28-24 6:36 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-22-24 2:07 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-22-24 2:07 AM s12 OTHER 91 PROD NO VACUUM ALARM CLEAR 04-18-24 11:33 AM s12 OTHER 91 PROD NO VACUUM ALARM ALARM 04-18-24 11:21 AM s12 OTHER 91 PROD NO VACUUM ALARM CLEAR 04-18-24 11:21 AM s12 OTHER 91 PROD HIGH LIQUID ALARM CLEAR 04-18-24 11:21 AM s12 OTHER 91 PROD HIGH LIQUID ALARM ALARM 04-18-24 11:20 AM s12 OTHER 91 PROD NO VACUUM ALARM ALARM 04-18-24 11:19 AM s12 OTHER 91 PROD NO VACUUM ALARM CLEAR 04-18-24 11:13 AM s12 OTHER 91 PROD NO VACUUM ALARM ALARM 04-18-24 11:06 AM s12 OTHER 91 PROD NO VACUUM ALARM CLEAR 04-18-24 9:54 AM s12 OTHER 91 PROD COMMUNICATION ALARM CLEAR 04-18-24 9:41 AM s12 OTHER 91 PROD COMMUNICATION ALARM ALARM 04-18-24 9:36 AM L14 PIPE PREM FILL FUEL ALARM CLEAR 04-18-24 9:07 AM I11200 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 06-15-24 9:26 AM SYSTEM PAPER OUT CLEAR 06-15-24 9:26 AM SYSTEM PRINTER ERROR ALARM 06-15-24 9:26 AM SYSTEM PAPER OUT ALARM 06-15-24 9:26 AM SYSTEM PRINTER ERROR CLEAR 06-15-24 9:26 AM SYSTEM PAPER OUT CLEAR 06-15-24 9:26 AM SYSTEM PRINTER ERROR ALARM 06-15-24 9:26 AM SYSTEM PAPER OUT ALARM 06-15-24 9:26 AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 06-12-24 10:00 AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 06-11-24 10:04 AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 06-08-24 10:00 AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 06-02-24 10:00 AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 06-02-24 10:00 AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 06-01-24 10:03 AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 05-31-24 10:03 AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 05-26-24 10:04 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-24-24 10:00 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 05-24-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-22-24 10:04 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-21-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-18-24 10:03 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 05-17-24 10:03 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 05-16-24 10:00 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 05-15-24 10:02 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-09-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-08-24 10:02 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-07-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-06-24 10:01 AM SYSTEM PRINTER ERROR CLEAR 04-26-24 10:29 AM SYSTEM PAPER OUT CLEAR 04-26-24 10:29 AM SYSTEM PRINTER ERROR ALARM 04-26-24 10:28 AM SYSTEM PAPER OUT ALARM 04-26-24 10:28 AM s12 OTHER 91 PROD VACUUM WARNING CLEAR 04-18-24 11:19 AM s12 OTHER 91 PROD VACUUM WARNING ALARM 04-18-24 11:13 AM s12 OTHER 91 PROD VACUUM WARNING CLEAR 04-18-24 11:06 AM s12 OTHER 91 PROD VACUUM WARNING ALARM 04-18-24 10:04 AM OTHER ISD GROSS PRES WARN CLEAR 03-28-24 11:38 AM OTHER ISD GROSS PRES WARN ALARM 03-24-24 10:02 AM SYSTEM PRINTER ERROR CLEAR 03-16-24 10:56 AM SYSTEM PAPER OUT CLEAR 03-16-24 10:56 AM SYSTEM PRINTER ERROR ALARM 03-16-24 10:56 AM SYSTEM PAPER OUT ALARM 03-16-24 10:56 AM OTHER ISD GROSS PRES WARN CLEAR 03-14-24 10:00 AM OTHER ISD GROSS PRES WARN ALARM 03-11-24 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 03-04-24 5:21 PM OTHER ISD GROSS PRES WARN ALARM 03-03-24 10:03 AM OTHER ISD DEGRD PRES WARN CLEAR 02-28-24 10:00 AM OTHER ISD DEGRD PRES WARN ALARM 02-26-24 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 02-12-24 10:00 AM OTHER ISD GROSS PRES WARN ALARM 02-07-24 10:02 AM I20600 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 PREMIUM LOW PRODUCT ALARM 08-25-23 11:02 AM SUDDEN LOSS ALARM 12-01-23 11:09 AM 11-14-23 3:05 PM INVALID FUEL LEVEL 08-25-23 11:02 AM 07-27-23 5:35 PM PROBE OUT 12-01-23 4:46 PM 11-14-23 7:42 AM 09-01-23 7:26 AM HIGH WATER WARNING 07-24-23 4:51 AM DELIVERY NEEDED 12-04-23 9:22 PM 08-04-23 10:01 AM 07-27-23 5:27 PM TANK 3 DIESEL OVERFILL ALARM 01-31-23 7:29 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 06-25-24 2:26 PM I30200 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL TANK ANN 11-14-23 6:08 PM SENSOR OUT ALARM 11-14-23 5:08 PM LOW LIQUID ALARM 11-14-23 2:42 PM LOW LIQUID ALARM 2 PREM TANK ANN 11-30-23 9:25 AM LOW LIQUID ALARM 11-30-23 9:24 AM HIGH LIQUID ALARM 11-30-23 9:24 AM LOW LIQUID ALARM 3 DIESEL TANK ANN 11-14-23 6:09 PM SENSOR OUT ALARM 11-14-23 3:55 PM LOW LIQUID ALARM 11-14-23 3:54 PM LOW LIQUID ALARM 9 DIESEL STP 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 06-21-23 10:30 AM FUEL ALARM 10 DIESEL STP ANN 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 06-21-23 10:03 AM FUEL ALARM 11 UNL FILL 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 06-21-23 10:10 AM FUEL ALARM 12 UNL FILL ANN 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 06-21-23 10:01 AM FUEL ALARM 13 PREM FILL ANN 11-30-23 9:23 AM FUEL ALARM 11-14-23 6:09 PM SENSOR OUT ALARM 11-14-23 6:01 PM FUEL ALARM 14 PREM FILL 05-24-24 11:39 AM FUEL ALARM 05-23-24 4:48 PM FUEL ALARM 04-13-24 6:32 PM FUEL ALARM 15 DIESEL FILL 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 06-21-23 10:08 AM FUEL ALARM 16 DIESEL FILL ANN 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 06-21-23 10:00 AM FUEL ALARM 17 DIS 9-10 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:08 AM SENSOR OUT ALARM 06-21-23 11:06 AM SENSOR OUT ALARM 18 DIS 9-10 ANN 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:09 AM SENSOR OUT ALARM 06-21-23 11:07 AM SENSOR OUT ALARM 19 DIS 11-12 11-14-23 6:10 PM SENSOR OUT ALARM 09-28-23 5:36 PM FUEL ALARM 06-21-23 11:09 AM SENSOR OUT ALARM 20 DIS 11-12 ANN 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:09 AM SENSOR OUT ALARM 06-21-23 11:07 AM SENSOR OUT ALARM 21 UNL STP 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:09 AM SENSOR OUT ALARM 06-21-23 11:07 AM SENSOR OUT ALARM 22 UNL STP ANN 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:09 AM SENSOR OUT ALARM 06-21-23 11:04 AM FUEL ALARM 23 PREM STP 02-29-24 5:43 AM FUEL ALARM 11-30-23 9:17 AM FUEL ALARM 11-14-23 6:07 PM FUEL ALARM 24 PREM STP ANN 04-12-24 8:28 AM FUEL ALARM 04-12-24 8:24 AM FUEL ALARM 11-30-23 9:21 AM FUEL ALARM 25 DIS 1-2 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:11 AM SENSOR OUT ALARM 06-21-23 11:11 AM FUEL ALARM 26 DIS 1-2 ANN 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:07 AM SENSOR OUT ALARM 06-21-23 10:07 AM FUEL ALARM 27 DIS 3-4 06-21-23 11:07 AM SENSOR OUT ALARM 06-21-23 10:07 AM FUEL ALARM 07-06-22 10:29 AM SENSOR OUT ALARM 28 DIS 3-4 ANN 06-21-23 11:07 AM SENSOR OUT ALARM 06-21-23 10:46 AM FUEL ALARM 07-06-22 10:29 AM SENSOR OUT ALARM 29 DIS 5-6 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:11 AM SENSOR OUT ALARM 06-21-23 11:09 AM FUEL ALARM 30 DIS 5-6 ANN 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:12 AM SENSOR OUT ALARM 06-21-23 11:09 AM FUEL ALARM 31 DIS 7-8 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:12 AM SENSOR OUT ALARM 06-21-23 11:09 AM FUEL ALARM 32 DIS 7-8 ANN 11-14-23 6:10 PM SENSOR OUT ALARM 06-21-23 11:12 AM SENSOR OUT ALARM 06-21-23 11:09 AM FUEL ALARM I31600 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PRESS DISP 1-2 2 FM DISP 1-2 3 FM DISP 3-4 4 FM DISP 5-6 5 FM DISP 7-8 6 FM DISP 9-10 7 FM DISP 11-12 8 87 PROD 09-28-23 6:09 PM HIGH LIQUID ALARM 09-28-23 6:08 PM NO VACUUM ALARM 09-28-23 5:57 PM HIGH LIQUID ALARM 9 91 VENT 02-22-24 2:15 AM NO VACUUM ALARM 11-30-23 9:36 AM NO VACUUM ALARM 11-30-23 9:36 AM HIGH LIQUID ALARM 10 87-91 VAPOR 11-14-23 1:42 PM COMMUNICATION ALARM 10-22-23 6:42 PM COMMUNICATION ALARM 10-22-23 12:02 AM COMMUNICATION ALARM 11 87 VENT 11-14-23 4:24 PM NO VACUUM ALARM 09-28-23 6:08 PM HIGH LIQUID ALARM 09-28-23 6:08 PM NO VACUUM ALARM 12 91 PROD 04-18-24 11:21 AM NO VACUUM ALARM 04-18-24 11:20 AM HIGH LIQUID ALARM 04-18-24 11:19 AM NO VACUUM ALARM 14 DIESEL PROD 06-21-23 11:29 AM NO VACUUM ALARM 06-21-23 11:28 AM HIGH LIQUID ALARM 07-06-22 11:00 AM NO VACUUM ALARM 15 DIESEL VENT 11-14-23 4:24 PM NO VACUUM ALARM 06-21-23 11:31 AM NO VACUUM ALARM 06-21-23 11:28 AM HIGH LIQUID ALARM 16 ATM PRESS I40200 06-25-24 2:26 PM I40300 06-25-24 2:26 PM I34200 06-25-24 2:26 PM I34700 06-25-24 2:26 PM IV0100 06-25-24 2:26 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-11 10:04:26 A/L RATIO DEGRADATION FP12 BLEND3 0.80 24-06-07 10:04:25 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 24-06-06 10:04:21 A/L RATIO DEGRADATION FP 7 BLEND3 0.76 24-06-05 10:03:21 A/L RATIO DEGRADATION FP 7 BLEND3 0.76 24-06-04 10:03:28 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 24-06-03 10:03:55 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 24-06-02 10:03:26 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 24-06-01 10:03:52 A/L RATIO DEGRADATION FP 7 BLEND3 0.79 24-06-01 10:03:52 A/L RATIO DEGRADATION FP 6 BLEND3 0.80 24-06-01 10:03:52 A/L RATIO DEGRADATION FP 1 BLEND3 0.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-02 10:03:26 A/L RATIO DEGRADATION FP 1 BLEND3 0.78 24-05-24 10:03:29 A/L RATIO DEGRADATION FP 2 BLEND3 0.79 23-11-13 10:02:33 SENSOR OUT SELFTEST T 2 23-11-12 10:02:36 SENSOR OUT SELFTEST T 2 23-11-11 10:02:33 SENSOR OUT SELFTEST T 2 23-11-10 10:02:58 SENSOR OUT SELFTEST T 2 23-11-09 10:03:34 SENSOR OUT SELFTEST T 2 23-11-08 10:04:13 SENSOR OUT SELFTEST T 2 23-11-08 10:04:13 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-11-07 10:04:02 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 3:FM DISP 5-6 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 24-06-02 10:19:24 COLLECTION TEST HH01 GRADE TEST MANUALLY CLEARED 24-06-02 10:16:35 PUMPS MANUALLY RE-ENABLED 24-06-02 10:03:26 A/L RATIO GROSS DEGRADATION DISABLED FP 01 BLEND3 24-05-24 10:08:04 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED 24-05-24 10:07:45 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 24-05-24 10:04:13 PUMPS MANUALLY RE-ENABLED 24-05-24 10:03:29 A/L RATIO GROSS DEGRADATION DISABLED FP 02 BLEND3 24-04-10 10:25:00 TIME CHANGE DETECTED AT: 24-04-10 11:22:13 24-04-07 03:00:00 TIME CHANGE DETECTED AT: 24-04-07 02:00:13 24-03-28 11:38:16 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED Post Alarm History Responses Received: I10200 06-25-24 5:07 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39536 39637 2 7SMARTSENSOR BD 507076 509991 3 UNUSED 4977997 5004872 4 4 PROBE / G.T. 162746 163108 5 INTERSTITIAL BD 201384 202053 6 INTERSTITIAL BD 201595 201677 7 INTERSTITIAL BD 201173 201677 8 INTERSTITIAL BD 201363 201907 9 RELAY BOARD 14935 14949 10 STP SENSE BOARD 33180 33211 11 UNUSED 4980403 4998150 12 UNUSED 4974185 4990542 13 UNUSED 4972177 4990214 14 UNUSED 4970890 4985900 15 UNUSED 4969838 4987152 16 UNUSED 4973444 4987364 COMM 1 ELEC DISP INT. 101010 101105 COMM 2 RS232 SERIAL BD 14955 14949 COMM 3 UNUSED 4975744 4999999 COMM 4 UNUSED 4973580 4993720 COMM 5 UNUSED 4969584 4993527 COMM 6 UNUSED 4969467 4994259 I90200 06-25-24 5:07 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 06-25-24 5:07 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 3 ANNULAR DIESEL TANK ANN HIGH LIQUID ALARM CLEAR 06-25-24 3:21 PM L 1 ANNULAR UNL TANK ANN LOW LIQUID ALARM CLEAR 06-25-24 3:21 PM L 1 ANNULAR UNL TANK ANN LOW LIQUID ALARM ALARM 06-25-24 3:21 PM L 1 ANNULAR UNL TANK ANN HIGH LIQUID ALARM CLEAR 06-25-24 3:21 PM L 2 ANNULAR PREM TANK ANN HIGH LIQUID ALARM CLEAR 06-25-24 3:21 PM L 1 ANNULAR UNL TANK ANN LOW LIQUID ALARM CLEAR 06-25-24 3:21 PM L 1 ANNULAR UNL TANK ANN HIGH LIQUID ALARM ALARM 06-25-24 3:21 PM L 2 ANNULAR PREM TANK ANN LOW LIQUID ALARM CLEAR 06-25-24 3:21 PM L 2 ANNULAR PREM TANK ANN HIGH LIQUID ALARM ALARM 06-25-24 3:21 PM L 3 ANNULAR DIESEL TANK ANN LOW LIQUID ALARM CLEAR 06-25-24 3:21 PM L 3 ANNULAR DIESEL TANK ANN HIGH LIQUID ALARM ALARM 06-25-24 3:21 PM s14 OTHER DIESEL PROD HIGH LIQUID ALARM CLEAR 06-25-24 3:18 PM s15 OTHER DIESEL VENT HIGH LIQUID ALARM CLEAR 06-25-24 3:18 PM s15 OTHER DIESEL VENT NO VACUUM ALARM CLEAR 06-25-24 3:18 PM L 1 ANNULAR UNL TANK ANN LOW LIQUID ALARM ALARM 06-25-24 3:17 PM s15 OTHER DIESEL VENT NO VACUUM ALARM ALARM 06-25-24 3:17 PM s14 OTHER DIESEL PROD NO VACUUM ALARM CLEAR 06-25-24 3:17 PM L 2 ANNULAR PREM TANK ANN LOW LIQUID ALARM ALARM 06-25-24 3:16 PM s14 OTHER DIESEL PROD NO VACUUM ALARM ALARM 06-25-24 3:16 PM L 3 ANNULAR DIESEL TANK ANN LOW LIQUID ALARM ALARM 06-25-24 3:16 PM s15 OTHER DIESEL VENT HIGH LIQUID ALARM ALARM 06-25-24 3:15 PM s14 OTHER DIESEL PROD HIGH LIQUID ALARM ALARM 06-25-24 3:15 PM s11 OTHER 87 VENT HIGH LIQUID ALARM CLEAR 06-25-24 3:14 PM s 8 OTHER 87 PROD HIGH LIQUID ALARM CLEAR 06-25-24 3:14 PM s10 OTHER 87-91 VAPOR HIGH LIQUID ALARM CLEAR 06-25-24 3:14 PM s11 OTHER 87 VENT NO VACUUM ALARM CLEAR 06-25-24 3:13 PM s12 OTHER 91 PROD HIGH LIQUID ALARM CLEAR 06-25-24 3:13 PM s 9 OTHER 91 VENT HIGH LIQUID ALARM CLEAR 06-25-24 3:13 PM s 9 OTHER 91 VENT NO VACUUM ALARM CLEAR 06-25-24 3:13 PM s 9 OTHER 91 VENT NO VACUUM ALARM ALARM 06-25-24 3:12 PM s12 OTHER 91 PROD NO VACUUM ALARM CLEAR 06-25-24 3:12 PM s11 OTHER 87 VENT NO VACUUM ALARM ALARM 06-25-24 3:12 PM s12 OTHER 91 PROD NO VACUUM ALARM ALARM 06-25-24 3:12 PM s10 OTHER 87-91 VAPOR NO VACUUM ALARM CLEAR 06-25-24 3:11 PM s12 OTHER 91 PROD HIGH LIQUID ALARM ALARM 06-25-24 3:11 PM s 9 OTHER 91 VENT HIGH LIQUID ALARM ALARM 06-25-24 3:11 PM s 9 OTHER 91 VENT HIGH LIQUID ALARM CLEAR 06-25-24 3:11 PM s12 OTHER 91 PROD HIGH LIQUID ALARM CLEAR 06-25-24 3:11 PM s12 OTHER 91 PROD NO VACUUM ALARM CLEAR 06-25-24 3:11 PM s10 OTHER 87-91 VAPOR NO VACUUM ALARM ALARM 06-25-24 3:10 PM s 8 OTHER 87 PROD NO VACUUM ALARM CLEAR 06-25-24 3:10 PM s12 OTHER 91 PROD NO VACUUM ALARM ALARM 06-25-24 3:10 PM s12 OTHER 91 PROD HIGH LIQUID ALARM ALARM 06-25-24 3:10 PM s 9 OTHER 91 VENT HIGH LIQUID ALARM ALARM 06-25-24 3:10 PM s 8 OTHER 87 PROD NO VACUUM ALARM ALARM 06-25-24 3:09 PM s10 OTHER 87-91 VAPOR HIGH LIQUID ALARM ALARM 06-25-24 3:09 PM s11 OTHER 87 VENT HIGH LIQUID ALARM ALARM 06-25-24 3:09 PM s 8 OTHER 87 PROD HIGH LIQUID ALARM ALARM 06-25-24 3:09 PM L16 ANNULAR DIESEL FILL ANN SENSOR OUT ALARM CLEAR 06-25-24 3:05 PM L 3 ANNULAR DIESEL TANK ANN SENSOR OUT ALARM CLEAR 06-25-24 3:05 PM I11200 06-25-24 5:07 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 06-15-24 9:26 AM SYSTEM PAPER OUT CLEAR 06-15-24 9:26 AM SYSTEM PRINTER ERROR ALARM 06-15-24 9:26 AM SYSTEM PAPER OUT ALARM 06-15-24 9:26 AM SYSTEM PRINTER ERROR CLEAR 06-15-24 9:26 AM SYSTEM PAPER OUT CLEAR 06-15-24 9:26 AM SYSTEM PRINTER ERROR ALARM 06-15-24 9:26 AM SYSTEM PAPER OUT ALARM 06-15-24 9:26 AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 06-12-24 10:00 AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 06-11-24 10:04 AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 06-08-24 10:00 AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 06-02-24 10:00 AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 06-02-24 10:00 AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 06-01-24 10:03 AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 05-31-24 10:03 AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 05-26-24 10:04 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-24-24 10:00 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 05-24-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-22-24 10:04 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-21-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-18-24 10:03 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 05-17-24 10:03 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 05-16-24 10:00 AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 05-15-24 10:02 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-09-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-08-24 10:02 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-07-24 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-06-24 10:01 AM SYSTEM PRINTER ERROR CLEAR 04-26-24 10:29 AM SYSTEM PAPER OUT CLEAR 04-26-24 10:29 AM SYSTEM PRINTER ERROR ALARM 04-26-24 10:28 AM SYSTEM PAPER OUT ALARM 04-26-24 10:28 AM s12 OTHER 91 PROD VACUUM WARNING CLEAR 04-18-24 11:19 AM s12 OTHER 91 PROD VACUUM WARNING ALARM 04-18-24 11:13 AM s12 OTHER 91 PROD VACUUM WARNING CLEAR 04-18-24 11:06 AM s12 OTHER 91 PROD VACUUM WARNING ALARM 04-18-24 10:04 AM OTHER ISD GROSS PRES WARN CLEAR 03-28-24 11:38 AM OTHER ISD GROSS PRES WARN ALARM 03-24-24 10:02 AM SYSTEM PRINTER ERROR CLEAR 03-16-24 10:56 AM SYSTEM PAPER OUT CLEAR 03-16-24 10:56 AM SYSTEM PRINTER ERROR ALARM 03-16-24 10:56 AM SYSTEM PAPER OUT ALARM 03-16-24 10:56 AM OTHER ISD GROSS PRES WARN CLEAR 03-14-24 10:00 AM OTHER ISD GROSS PRES WARN ALARM 03-11-24 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 03-04-24 5:21 PM OTHER ISD GROSS PRES WARN ALARM 03-03-24 10:03 AM OTHER ISD DEGRD PRES WARN CLEAR 02-28-24 10:00 AM OTHER ISD DEGRD PRES WARN ALARM 02-26-24 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 02-12-24 10:00 AM OTHER ISD GROSS PRES WARN ALARM 02-07-24 10:02 AM I20600 06-25-24 5:07 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 PREMIUM LOW PRODUCT ALARM 08-25-23 11:02 AM SUDDEN LOSS ALARM 12-01-23 11:09 AM 11-14-23 3:05 PM INVALID FUEL LEVEL 08-25-23 11:02 AM 07-27-23 5:35 PM PROBE OUT 12-01-23 4:46 PM 11-14-23 7:42 AM 09-01-23 7:26 AM HIGH WATER WARNING 07-24-23 4:51 AM DELIVERY NEEDED 12-04-23 9:22 PM 08-04-23 10:01 AM 07-27-23 5:27 PM TANK 3 DIESEL OVERFILL ALARM 01-31-23 7:29 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 06-25-24 5:07 PM I30200 06-25-24 5:07 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL TANK ANN 06-25-24 3:21 PM LOW LIQUID ALARM 06-25-24 3:21 PM HIGH LIQUID ALARM 06-25-24 3:17 PM LOW LIQUID ALARM 2 PREM TANK ANN 06-25-24 3:21 PM HIGH LIQUID ALARM 06-25-24 3:16 PM LOW LIQUID ALARM 06-25-24 3:03 PM SENSOR OUT ALARM 3 DIESEL TANK ANN 06-25-24 3:21 PM HIGH LIQUID ALARM 06-25-24 3:16 PM LOW LIQUID ALARM 06-25-24 3:03 PM SENSOR OUT ALARM 9 DIESEL STP 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:41 PM FUEL ALARM 11-14-23 6:09 PM SENSOR OUT ALARM 10 DIESEL STP ANN 06-25-24 3:03 PM SENSOR OUT ALARM 11-14-23 6:09 PM SENSOR OUT ALARM 06-21-23 11:02 AM SENSOR OUT ALARM 11 UNL FILL 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:47 PM FUEL ALARM 11-14-23 6:09 PM SENSOR OUT ALARM 12 UNL FILL ANN 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:47 PM FUEL ALARM 06-25-24 2:47 PM FUEL ALARM 13 PREM FILL ANN 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:44 PM FUEL ALARM 11-30-23 9:23 AM FUEL ALARM 14 PREM FILL 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:44 PM FUEL ALARM 05-24-24 11:39 AM FUEL ALARM 15 DIESEL FILL 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:42 PM FUEL ALARM 11-14-23 6:09 PM SENSOR OUT ALARM 16 DIESEL FILL ANN 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:42 PM FUEL ALARM 11-14-23 6:09 PM SENSOR OUT ALARM 17 DIS 9-10 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:52 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 18 DIS 9-10 ANN 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:58 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 19 DIS 11-12 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:53 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 20 DIS 11-12 ANN 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:53 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 21 UNL STP 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:37 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 22 UNL STP ANN 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:38 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 23 PREM STP 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:40 PM FUEL ALARM 02-29-24 5:43 AM FUEL ALARM 24 PREM STP ANN 06-25-24 3:03 PM SENSOR OUT ALARM 06-25-24 2:40 PM FUEL ALARM 04-12-24 8:28 AM FUEL ALARM 25 DIS 1-2 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:49 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 26 DIS 1-2 ANN 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:49 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 27 DIS 3-4 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:50 PM FUEL ALARM 06-21-23 11:07 AM SENSOR OUT ALARM 28 DIS 3-4 ANN 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:50 PM FUEL ALARM 06-21-23 11:07 AM SENSOR OUT ALARM 29 DIS 5-6 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:51 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 30 DIS 5-6 ANN 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:51 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 31 DIS 7-8 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:51 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM 32 DIS 7-8 ANN 06-25-24 3:04 PM SENSOR OUT ALARM 06-25-24 2:52 PM FUEL ALARM 11-14-23 6:10 PM SENSOR OUT ALARM I31600 06-25-24 5:07 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PRESS DISP 1-2 2 FM DISP 1-2 3 FM DISP 3-4 4 FM DISP 5-6 5 FM DISP 7-8 6 FM DISP 9-10 7 FM DISP 11-12 8 87 PROD 06-25-24 3:09 PM NO VACUUM ALARM 06-25-24 3:09 PM HIGH LIQUID ALARM 09-28-23 6:09 PM HIGH LIQUID ALARM 9 91 VENT 06-25-24 3:12 PM NO VACUUM ALARM 06-25-24 3:11 PM HIGH LIQUID ALARM 06-25-24 3:10 PM HIGH LIQUID ALARM 10 87-91 VAPOR 06-25-24 3:10 PM NO VACUUM ALARM 06-25-24 3:09 PM HIGH LIQUID ALARM 11-14-23 1:42 PM COMMUNICATION ALARM 11 87 VENT 06-25-24 3:12 PM NO VACUUM ALARM 06-25-24 3:09 PM HIGH LIQUID ALARM 11-14-23 4:24 PM NO VACUUM ALARM 12 91 PROD 06-25-24 3:12 PM NO VACUUM ALARM 06-25-24 3:11 PM HIGH LIQUID ALARM 06-25-24 3:10 PM NO VACUUM ALARM 14 DIESEL PROD 06-25-24 3:16 PM NO VACUUM ALARM 06-25-24 3:15 PM HIGH LIQUID ALARM 06-21-23 11:29 AM NO VACUUM ALARM 15 DIESEL VENT 06-25-24 3:17 PM NO VACUUM ALARM 06-25-24 3:15 PM HIGH LIQUID ALARM 11-14-23 4:24 PM NO VACUUM ALARM 16 ATM PRESS I40200 06-25-24 5:07 PM I40300 06-25-24 5:08 PM I34200 06-25-24 5:08 PM I34700 06-25-24 5:08 PM IV0100 06-25-24 5:08 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-11 10:04:26 A/L RATIO DEGRADATION FP12 BLEND3 0.80 24-06-07 10:04:25 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 24-06-06 10:04:21 A/L RATIO DEGRADATION FP 7 BLEND3 0.76 24-06-05 10:03:21 A/L RATIO DEGRADATION FP 7 BLEND3 0.76 24-06-04 10:03:28 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 24-06-03 10:03:55 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 24-06-02 10:03:26 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 24-06-01 10:03:52 A/L RATIO DEGRADATION FP 7 BLEND3 0.79 24-06-01 10:03:52 A/L RATIO DEGRADATION FP 6 BLEND3 0.80 24-06-01 10:03:52 A/L RATIO DEGRADATION FP 1 BLEND3 0.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-02 10:03:26 A/L RATIO DEGRADATION FP 1 BLEND3 0.78 24-05-24 10:03:29 A/L RATIO DEGRADATION FP 2 BLEND3 0.79 23-11-13 10:02:33 SENSOR OUT SELFTEST T 2 23-11-12 10:02:36 SENSOR OUT SELFTEST T 2 23-11-11 10:02:33 SENSOR OUT SELFTEST T 2 23-11-10 10:02:58 SENSOR OUT SELFTEST T 2 23-11-09 10:03:34 SENSOR OUT SELFTEST T 2 23-11-08 10:04:13 SENSOR OUT SELFTEST T 2 23-11-08 10:04:13 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 23-11-07 10:04:02 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 3:FM DISP 5-6 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 24-06-25 17:05:19 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-06-25 17:05:19 ISD STARTUP 24-06-25 16:20:03 ISD SHUTDOWN 24-06-25 16:19:39 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-06-25 16:19:39 ISD STARTUP 24-06-25 16:07:41 ISD SHUTDOWN 24-06-02 10:19:24 COLLECTION TEST HH01 GRADE TEST MANUALLY CLEARED 24-06-02 10:16:35 PUMPS MANUALLY RE-ENABLED 24-06-02 10:03:26 A/L RATIO GROSS DEGRADATION DISABLED FP 01 BLEND3 24-05-24 10:08:04 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED