HomeMy WebLinkAboutOPI 2024Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 10155965 07/03/2024 Jaco #5562 Fastrip #6 1640 S Chester Ave Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Brandon Nunez 1073967 10226373 09/06/2024 VeederRoot TLS-3XX Technician - C32655 10/11/2024 OPW - 1193585 04/14/2025 Industry Standard All Overfill Prevention Devices 07/03/2024 Total # of Pages 9 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes* ܆܆ No ܆܆ Yes* ܆܆ No ܆܆ Yes* ܆܆ No ܆܆ Yes* ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. T1: 87-1 UNL 71SO 71SO 71SO 71SO 84.5" 83.5" 83.75" 79.5" 93.23% 92.35% 92.81% 88.55% T2: DSL T3: 91 PNL T4: 87-2 UNL 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFW91 PNL 42" 125" 125" 127.75" 12,062 83.75" 11,167 12,032 92.81% 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFWDiesel 38.5" 121" 121" 124" 12,062 83.5" 11,140 12,062 92.35% 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFW87-1 Unleaded 37.5" 122" 120" 124" 12,062 84.5" 11,246 12,062 93.23% 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFW87-2 Unleaded 38.5" 118" 118" 120" 12,062 79.5" 10,682 12,062 88.55% Modern Welding Company Subsidiaries Nationwide www.modweldco.com modern@modweldco.com Tank Calibration Chart Cylindrical Tank / Horizontal Orientation Striker Plate: 0 inches Diameter: 96 inches Length: 385 inches Total Volume: 12,064 gallons Depth (inches) Volume (gallons) 0.000 0 0.125 1 0.250 3 0.375 5 0.500 8 0.625 11 0.750 14 0.875 18 1.000 22 1.125 26 1.250 30 1.375 35 1.500 40 1.625 45 1.750 50 1.875 56 2.000 61 2.125 67 2.250 73 2.375 79 2.500 85 2.625 92 2.750 98 2.875 105 3.000 112 3.125 119 3.250 126 3.375 134 3.500 141 3.625 149 3.750 156 3.875 164 4.000 172 4.125 180 Depth (inches) Volume (gallons) 4.250 188 4.375 196 4.500 205 4.625 213 4.750 222 4.875 231 5.000 240 5.125 249 5.250 258 5.375 267 5.500 276 5.625 285 5.750 295 5.875 304 6.000 314 6.125 324 6.250 333 6.375 343 6.500 353 6.625 363 6.750 374 6.875 384 7.000 394 7.125 405 7.250 415 7.375 426 7.500 437 7.625 447 7.750 458 7.875 469 8.000 480 8.125 491 8.250 502 8.375 514 Depth (inches) Volume (gallons) 8.500 525 8.625 536 8.750 548 8.875 559 9.000 571 9.125 583 9.250 595 9.375 606 9.500 618 9.625 630 9.750 642 9.875 654 10.000 667 10.125 679 10.250 691 10.375 704 10.500 716 10.625 729 10.750 741 10.875 754 11.000 766 11.125 779 11.250 792 11.375 805 11.500 818 11.625 831 11.750 844 11.875 857 12.000 870 12.125 884 12.250 897 12.375 910 12.500 924 12.625 937 Depth (inches) Volume (gallons) 12.750 951 12.875 964 13.000 978 13.125 992 13.250 1,006 13.375 1,019 13.500 1,033 13.625 1,047 13.750 1,061 13.875 1,075 14.000 1,089 14.125 1,103 14.250 1,118 14.375 1,132 14.500 1,146 14.625 1,161 14.750 1,175 14.875 1,189 15.000 1,204 15.125 1,218 15.250 1,233 15.375 1,248 15.500 1,262 15.625 1,277 15.750 1,292 15.875 1,307 16.000 1,322 16.125 1,337 16.250 1,351 16.375 1,367 16.500 1,382 16.625 1,397 16.750 1,412 16.875 1,427 Depth (inches) Volume (gallons) 17.000 1,442 17.125 1,458 17.250 1,473 17.375 1,488 17.500 1,504 17.625 1,519 17.750 1,535 17.875 1,550 18.000 1,566 18.125 1,581 18.250 1,597 18.375 1,613 18.500 1,629 18.625 1,644 18.750 1,660 18.875 1,676 19.000 1,692 19.125 1,708 19.250 1,724 19.375 1,740 19.500 1,756 19.625 1,772 19.750 1,788 19.875 1,805 20.000 1,821 20.125 1,837 20.250 1,853 20.375 1,870 20.500 1,886 20.625 1,902 20.750 1,919 20.875 1,935 21.000 1,952 21.125 1,968 Depth (inches) Volume (gallons) 21.250 1,985 21.375 2,002 21.500 2,018 21.625 2,035 21.750 2,052 21.875 2,069 22.000 2,085 22.125 2,102 22.250 2,119 22.375 2,136 22.500 2,153 22.625 2,170 22.750 2,187 22.875 2,204 23.000 2,221 23.125 2,238 23.250 2,255 23.375 2,272 23.500 2,289 23.625 2,307 23.750 2,324 23.875 2,341 24.000 2,358 24.125 2,376 24.250 2,393 24.375 2,411 24.500 2,428 24.625 2,445 24.750 2,463 24.875 2,480 25.000 2,498 25.125 2,516 25.250 2,533 25.375 2,551 Depth (inches) Volume (gallons) 25.500 2,568 25.625 2,586 25.750 2,604 25.875 2,622 26.000 2,639 26.125 2,657 26.250 2,675 26.375 2,693 26.500 2,711 26.625 2,729 26.750 2,746 26.875 2,764 27.000 2,782 27.125 2,800 27.250 2,818 27.375 2,836 27.500 2,854 27.625 2,873 27.750 2,891 27.875 2,909 28.000 2,927 28.125 2,945 28.250 2,963 28.375 2,982 28.500 3,000 28.625 3,018 28.750 3,037 28.875 3,055 29.000 3,073 29.125 3,092 29.250 3,110 29.375 3,128 29.500 3,147 29.625 3,165 Page 1 of 3 This volumetric tank chart is supplied to you for informational purposes only. These capacity calculations are based on theoretical volumes not actual volumes, and do not reflect atmospheric conditions or thermal expansion/contraction due to temperature changes. If internal accessories such as pumps are present, displacement of these accessories must be considered. Therefore, neither Modern Welding Company nor its officers, directors, employee affiliates or subsidiaries shall be liable for the use of this information covered within. This information is advisory only and the use of the material and methods is solely at the risk of the user. Depth (inches) Volume (gallons) 29.750 3,184 29.875 3,202 30.000 3,221 30.125 3,239 30.250 3,258 30.375 3,277 30.500 3,295 30.625 3,314 30.750 3,332 30.875 3,351 31.000 3,370 31.125 3,389 31.250 3,407 31.375 3,426 31.500 3,445 31.625 3,464 31.750 3,482 31.875 3,501 32.000 3,520 32.125 3,539 32.250 3,558 32.375 3,577 32.500 3,596 32.625 3,615 32.750 3,634 32.875 3,653 33.000 3,672 33.125 3,691 33.250 3,710 33.375 3,729 33.500 3,748 33.625 3,767 33.750 3,786 33.875 3,805 34.000 3,824 34.125 3,843 34.250 3,862 34.375 3,881 34.500 3,901 34.625 3,920 34.750 3,939 Depth (inches) Volume (gallons) 34.875 3,958 35.000 3,978 35.125 3,997 35.250 4,016 35.375 4,035 35.500 4,055 35.625 4,074 35.750 4,093 35.875 4,113 36.000 4,132 36.125 4,151 36.250 4,171 36.375 4,190 36.500 4,210 36.625 4,229 36.750 4,248 36.875 4,268 37.000 4,287 37.125 4,307 37.250 4,326 37.375 4,346 37.500 4,365 37.625 4,385 37.750 4,404 37.875 4,424 38.000 4,444 38.125 4,463 38.250 4,483 38.375 4,502 38.500 4,522 38.625 4,541 38.750 4,561 38.875 4,581 39.000 4,600 39.125 4,620 39.250 4,640 39.375 4,659 39.500 4,679 39.625 4,699 39.750 4,718 39.875 4,738 Depth (inches) Volume (gallons) 40.000 4,758 40.125 4,778 40.250 4,797 40.375 4,817 40.500 4,837 40.625 4,857 40.750 4,876 40.875 4,896 41.000 4,916 41.125 4,936 41.250 4,955 41.375 4,975 41.500 4,995 41.625 5,015 41.750 5,035 41.875 5,055 42.000 5,074 42.125 5,094 42.250 5,114 42.375 5,134 42.500 5,154 42.625 5,174 42.750 5,194 42.875 5,213 43.000 5,233 43.125 5,253 43.250 5,273 43.375 5,293 43.500 5,313 43.625 5,333 43.750 5,353 43.875 5,373 44.000 5,393 44.125 5,413 44.250 5,432 44.375 5,452 44.500 5,472 44.625 5,492 44.750 5,512 44.875 5,532 45.000 5,552 Depth (inches) Volume (gallons) 45.125 5,572 45.250 5,592 45.375 5,612 45.500 5,632 45.625 5,652 45.750 5,672 45.875 5,692 46.000 5,712 46.125 5,732 46.250 5,752 46.375 5,772 46.500 5,792 46.625 5,812 46.750 5,832 46.875 5,852 47.000 5,872 47.125 5,892 47.250 5,912 47.375 5,932 47.500 5,952 47.625 5,972 47.750 5,992 47.875 6,012 48.000 6,032 48.125 6,052 48.250 6,072 48.375 6,092 48.500 6,112 48.625 6,132 48.750 6,152 48.875 6,172 49.000 6,192 49.125 6,212 49.250 6,232 49.375 6,252 49.500 6,272 49.625 6,292 49.750 6,312 49.875 6,332 50.000 6,352 50.125 6,372 Depth (inches) Volume (gallons) 50.250 6,392 50.375 6,412 50.500 6,432 50.625 6,452 50.750 6,472 50.875 6,492 51.000 6,512 51.125 6,532 51.250 6,551 51.375 6,571 51.500 6,591 51.625 6,611 51.750 6,631 51.875 6,651 52.000 6,671 52.125 6,691 52.250 6,711 52.375 6,731 52.500 6,751 52.625 6,771 52.750 6,791 52.875 6,811 53.000 6,830 53.125 6,850 53.250 6,870 53.375 6,890 53.500 6,910 53.625 6,930 53.750 6,950 53.875 6,970 54.000 6,989 54.125 7,009 54.250 7,029 54.375 7,049 54.500 7,069 54.625 7,088 54.750 7,108 54.875 7,128 55.000 7,148 55.125 7,168 55.250 7,187 Depth (inches) Volume (gallons) 55.375 7,207 55.500 7,227 55.625 7,247 55.750 7,266 55.875 7,286 56.000 7,306 56.125 7,326 56.250 7,345 56.375 7,365 56.500 7,385 56.625 7,404 56.750 7,424 56.875 7,444 57.000 7,463 57.125 7,483 57.250 7,503 57.375 7,522 57.500 7,542 57.625 7,561 57.750 7,581 57.875 7,601 58.000 7,620 58.125 7,640 58.250 7,659 58.375 7,679 58.500 7,698 58.625 7,718 58.750 7,737 58.875 7,757 59.000 7,776 59.125 7,796 59.250 7,815 59.375 7,835 59.500 7,854 59.625 7,874 59.750 7,893 59.875 7,912 60.000 7,932 60.125 7,951 60.250 7,970 60.375 7,990 Depth (inches) Volume (gallons) 60.500 8,009 60.625 8,028 60.750 8,048 60.875 8,067 61.000 8,086 61.125 8,105 61.250 8,125 61.375 8,144 61.500 8,163 61.625 8,182 61.750 8,201 61.875 8,221 62.000 8,240 62.125 8,259 62.250 8,278 62.375 8,297 62.500 8,316 62.625 8,335 62.750 8,354 62.875 8,373 63.000 8,392 63.125 8,411 63.250 8,430 63.375 8,449 63.500 8,468 63.625 8,487 63.750 8,506 63.875 8,525 64.000 8,544 64.125 8,562 64.250 8,581 64.375 8,600 64.500 8,619 64.625 8,638 64.750 8,656 64.875 8,675 65.000 8,694 65.125 8,713 65.250 8,731 65.375 8,750 65.500 8,769 Cylindrical Tank / Horizontal Orientation Striker Plate: 0 inches | Diameter: 96 inches | Length: 385 inches | Total Volume: 12,064 gallons Page 2 of 3 Depth (inches) Volume (gallons) 65.625 8,787 65.750 8,806 65.875 8,824 66.000 8,843 66.125 8,861 66.250 8,880 66.375 8,898 66.500 8,917 66.625 8,935 66.750 8,954 66.875 8,972 67.000 8,990 67.125 9,009 67.250 9,027 67.375 9,045 67.500 9,064 67.625 9,082 67.750 9,100 67.875 9,118 68.000 9,137 68.125 9,155 68.250 9,173 68.375 9,191 68.500 9,209 68.625 9,227 68.750 9,245 68.875 9,263 69.000 9,281 69.125 9,299 69.250 9,317 69.375 9,335 69.500 9,353 69.625 9,371 69.750 9,389 69.875 9,407 70.000 9,424 70.125 9,442 70.250 9,460 70.375 9,478 70.500 9,495 70.625 9,513 Depth (inches) Volume (gallons) 70.750 9,531 70.875 9,548 71.000 9,566 71.125 9,583 71.250 9,601 71.375 9,618 71.500 9,636 71.625 9,653 71.750 9,671 71.875 9,688 72.000 9,705 72.125 9,723 72.250 9,740 72.375 9,757 72.500 9,774 72.625 9,791 72.750 9,809 72.875 9,826 73.000 9,843 73.125 9,860 73.250 9,877 73.375 9,894 73.500 9,911 73.625 9,928 73.750 9,945 73.875 9,962 74.000 9,978 74.125 9,995 74.250 10,012 74.375 10,029 74.500 10,045 74.625 10,062 74.750 10,079 74.875 10,095 75.000 10,112 75.125 10,128 75.250 10,145 75.375 10,161 75.500 10,178 75.625 10,194 75.750 10,210 Depth (inches) Volume (gallons) 75.875 10,227 76.000 10,243 76.125 10,259 76.250 10,275 76.375 10,291 76.500 10,308 76.625 10,324 76.750 10,340 76.875 10,356 77.000 10,372 77.125 10,388 77.250 10,403 77.375 10,419 77.500 10,435 77.625 10,451 77.750 10,467 77.875 10,482 78.000 10,498 78.125 10,513 78.250 10,529 78.375 10,545 78.500 10,560 78.625 10,575 78.750 10,591 78.875 10,606 79.000 10,621 79.125 10,637 79.250 10,652 79.375 10,667 79.500 10,682 79.625 10,697 79.750 10,712 79.875 10,727 80.000 10,742 80.125 10,757 80.250 10,772 80.375 10,787 80.500 10,801 80.625 10,816 80.750 10,831 80.875 10,845 Depth (inches) Volume (gallons) 81.000 10,860 81.125 10,874 81.250 10,889 81.375 10,903 81.500 10,918 81.625 10,932 81.750 10,946 81.875 10,960 82.000 10,974 82.125 10,989 82.250 11,003 82.375 11,017 82.500 11,030 82.625 11,044 82.750 11,058 82.875 11,072 83.000 11,086 83.125 11,099 83.250 11,113 83.375 11,126 83.500 11,140 83.625 11,153 83.750 11,167 83.875 11,180 84.000 11,193 84.125 11,207 84.250 11,220 84.375 11,233 84.500 11,246 84.625 11,259 84.750 11,272 84.875 11,284 85.000 11,297 85.125 11,310 85.250 11,323 85.375 11,335 85.500 11,348 85.625 11,360 85.750 11,373 85.875 11,385 86.000 11,397 Depth (inches) Volume (gallons) 86.125 11,409 86.250 11,421 86.375 11,433 86.500 11,445 86.625 11,457 86.750 11,469 86.875 11,481 87.000 11,493 87.125 11,504 87.250 11,516 87.375 11,527 87.500 11,539 87.625 11,550 87.750 11,561 87.875 11,572 88.000 11,584 88.125 11,595 88.250 11,606 88.375 11,616 88.500 11,627 88.625 11,638 88.750 11,648 88.875 11,659 89.000 11,669 89.125 11,680 89.250 11,690 89.375 11,700 89.500 11,710 89.625 11,720 89.750 11,730 89.875 11,740 90.000 11,750 90.125 11,759 90.250 11,769 90.375 11,778 90.500 11,788 90.625 11,797 90.750 11,806 90.875 11,815 91.000 11,824 91.125 11,833 Depth (inches) Volume (gallons) 91.250 11,842 91.375 11,850 91.500 11,859 91.625 11,867 91.750 11,876 91.875 11,884 92.000 11,892 92.125 11,900 92.250 11,907 92.375 11,915 92.500 11,923 92.625 11,930 92.750 11,937 92.875 11,945 93.000 11,952 93.125 11,959 93.250 11,965 93.375 11,972 93.500 11,978 93.625 11,985 93.750 11,991 93.875 11,997 94.000 12,003 94.125 12,008 94.250 12,014 94.375 12,019 94.500 12,024 94.625 12,029 94.750 12,033 94.875 12,038 95.000 12,042 95.125 12,046 95.250 12,050 95.375 12,053 95.500 12,056 95.625 12,059 95.750 12,061 95.875 12,063 96.000 12,064 Cylindrical Tank / Horizontal Orientation Striker Plate: 0 inches | Diameter: 96 inches | Length: 385 inches | Total Volume: 12,064 gallons