Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FMC 2024
Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10159161 7-25-24 Jaco #7781 Fastrip #22 (South) 4013 South H Street Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Rockland Kirk 1073967 10241356 9-29-24 GVR C32654 9-28-24 VMI #5254 #5255 10-3-24 7-25-24 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder-Root TLS-350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 UNL 1 STP L3 208 DIESEL STP L4 420 DIESEL ANN L5 208 REG 2 STP L6 420 REG 2 ANN L7 208 SUPER STP L8 420 SUPER ANN L9 208 DISP 1-2 L10 208 DISP 3-4 L11 208 DISP 5-6 L12 208 DISP 7-8 L13 420 T1 87 ANN Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 T2 FX1V 91 T3 FX1DV DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. F EXISTING BUILDING NOPARKING 56L11 #7-781 78L10 34L12 12L9 12,000 GALLON87-1 UNLEADED 12,000 GALLON87-2 UNLEADED 12,000 GALLONPREMIUM 12,000 GALLONDIESEL V AL2 STPL1 FV AL6 STPL5 FV AL8 STPL7 F AL4 STPL3 109L91413L121211L101615L122019L141817L1312,000 GALLON87 UNLEADED12,000 GALLONPREMIUM12,000 GALLONDIESELFAL6STPL5FVAL4STPL3FVAL2STPL1NOPARKING G W 7-721 7-781 #7-721DUMPSTER H H PRICE SIGN PRICE SIGN 40' STORAGE CONTA INER S. H ST.WHITE LN.PROPERTY LINE PROPERTY LINE N CAT C HBAS I N 721 LEGEND L1 87 STP L2 87 ANNULAR L3 91 STP L4 91 ANNULAR L5 DSL STP L6 DSL ANNULAR L9 UDC 9 - 10 L10 UDC 11 -12 L11 UDC 13 - 14 L12 UDC 15 - 16 L13 UDC 17 - 18 L14 UDC 19 - 20 781 LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 DSL STP L4 DSL ANNULAR L5 87-2 STP L6 87-2 ANNULAR L7 91 STP L8 91 ANNULAR L9 UDC 1 -2 L10 UDC 7 - 8 L11 UDC 5 -6 L12 UDC 3 - 4 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 3/2 INCH DOUBLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM W G A H P V SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 3/32"=1'-0" INCHES012 SHEET SIZE 22 X 34 4013 S. H ST. BAKERSFIELD, CA 93304 PROJECT OWNER: JAMIESON HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FASTRIP #7721 FACILITY ID 15-021-100296 CERS ID 10159161 FASTRIP #7781 FACILITY ID 15-021-003022 CERS ID 10159163 4013 S. H ST. BAKERSFIELD, CA 93304 03/02/17 REV.S. H ST.WHITE LN. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,' 6KHDU9DOYH7\SH3URGXFW9DSRU,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//& Jaco #7781 Fastrip #22 (South)4013 South H StreetBakersfield101591611-23-4 5-687918791DSL879187911-23-43-45-67-87-8ProductProductProductProductProductProductProductProductProductRockland Kirk APPENDIX C-10 7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,' 6KHDU9DOYH7\SH3URGXFW9DSRU,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBDSL7-8ProductRockland Kirk Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10159161 7-25-24 Jaco #7781 Fastrip #22 (South) 4013 South H Street Bakersfield 93304 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Rockland Kirk 1073967 10241356 9-29-24 OPW Phase 1 EVR VR-102 #1193547 2-15-24 RP1200 Spill buckets 7-25-24 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 87-1 OPW T2 87-2 OPW T3 91 OPW T4 DSL OPW Responses Received: 200 FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 JUL 25, 2024 1:01 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 8332 72.72 0.0 86.0 3730 2 UNL 2 9352 80.72 0.9 86.3 2710 3 PNL 3473 36.81 0.8 86.6 8589 4 DIESEL 6750 60.98 0.0 88.9 5312 I90500 JUL 25, 2024 1:01 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 25, 2024 1:01 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 25, 2024 1:01 PM SHIFT TIME 1 : 6:00 AM I50202 JUL 25, 2024 1:01 PM SHIFT TIME 2 : DISABLED I50203 JUL 25, 2024 1:01 PM SHIFT TIME 3 : DISABLED I50204 JUL 25, 2024 1:01 PM SHIFT TIME 4 : DISABLED I54600 JUL 25, 2024 1:01 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 25, 2024 1:01 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 25, 2024 1:01 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 25, 2024 1:01 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 25, 2024 1:01 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 25, 2024 1:01 PM PRINT TC VOLUMES ENABLED I50E00 JUL 25, 2024 1:01 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 25, 2024 1:01 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 25, 2024 1:01 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 25, 2024 1:01 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 25, 2024 1:01 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 25, 2024 1:01 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 25, 2024 1:01 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 25, 2024 1:01 PM TANK CHART SECURITY DISABLED I5BD00 JUL 25, 2024 1:01 PM CUSTOM ALARM LABELS DISABLED I56000 JUL 25, 2024 1:01 PM MASS/DENSITY DISABLED I88101 JUL 25, 2024 1:01 PM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 JUL 25, 2024 1:01 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 25, 2024 1:01 PM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 JUL 25, 2024 1:01 PM I88105 JUL 25, 2024 1:01 PM I88106 JUL 25, 2024 1:01 PM I52000 JUL 25, 2024 1:01 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUL 11, 2017 DISABLED 2 ON DATE JUL 11, 2017 DISABLED 3 ON DATE JUL 11, 2017 DISABLED 4 ON DATE JUL 11, 2017 DISABLED 5 ON DATE JUL 11, 2017 DISABLED 6 ON DATE JUL 11, 2017 DISABLED 7 ON DATE JUL 11, 2017 DISABLED 8 ON DATE JUL 11, 2017 DISABLED I60100 JUL 25, 2024 1:01 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 UNL 2 ON 3 PNL ON 4 DIESEL ON I60200 JUL 25, 2024 1:01 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 UNL 2 3 PNL 4 DIESEL I60300 JUL 25, 2024 1:01 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 2 3 PNL 3 4 DIESEL 4 I60900 JUL 25, 2024 1:01 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 UNL 2 0.000700 3 PNL 0.000700 4 DIESEL 0.000450 I60700 JUL 25, 2024 1:01 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 111.50 2 UNL 2 111.50 3 PNL 111.50 4 DIESEL 111.50 I60A00 JUL 25, 2024 1:01 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12062 2 UNL 2 1 PT 12062 3 PNL 1 PT 12062 4 DIESEL 1 PT 12062 I60400 JUL 25, 2024 1:01 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I60500 JUL 25, 2024 1:01 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 2 UNL 2 12062 0 0 0 3 PNL 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 JUL 25, 2024 1:01 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 25, 2024 1:01 PM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 UNL 2 NO 3 PNL NO 4 DIESEL NO I62F00 JUL 25, 2024 1:01 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 3.0 IN. 2 UNL 2 3.0 IN. 3 PNL 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 25, 2024 1:01 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 UNL 2 2.0 3 PNL 2.0 4 DIESEL 2.0 I64200 JUL 25, 2024 1:01 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 UNL 2 LOW 3 PNL LOW 4 DIESEL LOW I62400 JUL 25, 2024 1:01 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 UNL 2 3.0 3 PNL 3.0 4 DIESEL 3.0 I62800 JUL 25, 2024 1:01 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I62300 JUL 25, 2024 1:01 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10856 2 UNL 2 10856 3 PNL 10856 4 DIESEL 10856 I62200 JUL 25, 2024 1:01 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11459 2 UNL 2 11459 3 PNL 11459 4 DIESEL 11459 I62900 JUL 25, 2024 1:01 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1809 2 UNL 2 1809 3 PNL 1809 4 DIESEL 1809 I62100 JUL 25, 2024 1:01 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 500 2 UNL 2 500 3 PNL 500 4 DIESEL 500 I62600 JUL 25, 2024 1:01 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I62500 JUL 25, 2024 1:01 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 150 3 PNL 99 4 DIESEL 99 I60800 JUL 25, 2024 1:01 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 2.00 2 UNL 2 2.00 3 PNL 0.00 4 DIESEL 0.00 I60B00 JUL 25, 2024 1:01 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 25, 2024 1:01 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 UNL 2 0.00 3 PNL 0.00 4 DIESEL 0.00 I61200 JUL 25, 2024 1:01 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 NONE NONE 2 UNL 2 NONE NONE 3 PNL NONE NONE 4 DIESEL NONE NONE I63600 JUL 25, 2024 1:02 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62A00 JUL 25, 2024 1:02 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62C00 JUL 25, 2024 1:02 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 UNL 2 STANDARD 3 PNL STANDARD 4 DIESEL STANDARD I62D00 JUL 25, 2024 1:02 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 25, 2024 1:02 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 UNL 2 OFF OFF 3 PNL OFF OFF 4 DIESEL OFF OFF I63000 JUL 25, 2024 1:02 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I63200 JUL 25, 2024 1:02 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I61000 JUL 25, 2024 1:02 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63A00 JUL 25, 2024 1:02 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 UNL 2 10.00% 3 PNL 10.00% 4 DIESEL 10.00% I61100 JUL 25, 2024 1:02 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 16, 2006 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 25, 2024 1:02 PM CSLD PROBABLITY OF DETECTION I61400 JUL 25, 2024 1:02 PM CSLD CLIMATE FACTOR I61600 JUL 25, 2024 1:02 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 UNL 2 IMMEDIATE 3 PNL IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 25, 2024 1:02 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 UNL 2 DISABLED 3 PNL DISABLED 4 DIESEL DISABLED I61B00 JUL 25, 2024 1:02 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 25, 2024 1:02 PM CSLD REPORT ONLY I62B00 JUL 25, 2024 1:02 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 UNL 2 ??? 0, 0 3 PNL ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 25, 2024 1:02 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 25, 2024 1:02 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 UNL 2 0 3 PNL 0 4 DIESEL 0 I63500 JUL 25, 2024 1:02 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63900 JUL 25, 2024 1:02 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 UNL 2 END FACTOR: NONE 3 PNL END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 25, 2024 1:02 PM I77700 JUL 25, 2024 1:02 PM I77800 JUL 25, 2024 1:02 PM I78C00 JUL 25, 2024 1:02 PM I78300 JUL 25, 2024 1:02 PM I78F00 JUL 25, 2024 1:02 PM I78700 JUL 25, 2024 1:02 PM I70200 JUL 25, 2024 1:02 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DIESEL STP 4 DIESEL ANN 5 REG2 STP 6 REG 2 ANN 7 SUPER STP 8 SUPER ANN 9 DISP 1-2 10 DISP 7-8 11 DISP 5-6 12 DISP 3-4 13 T1 87 ANN 14 SO.TRANS 15 16 I70300 JUL 25, 2024 1:02 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 REG2 STP TRI-STATE (SINGLE FLOAT) 6 REG 2 ANN TRI-STATE (SINGLE FLOAT) 7 SUPER STP TRI-STATE (SINGLE FLOAT) 8 SUPER ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 7-8 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 T1 87 ANN TRI-STATE (SINGLE FLOAT) 14 SO.TRANS TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 25, 2024 1:02 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN OTHER SENSORS 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 REG2 STP STP SUMP 6 REG 2 ANN ANNULAR SPACE 7 SUPER STP STP SUMP 8 SUPER ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 7-8 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 T1 87 ANN ANNULAR SPACE 14 SO.TRANS OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUL 25, 2024 1:02 PM I74300 JUL 25, 2024 1:02 PM I74400 JUL 25, 2024 1:02 PM I74700 JUL 25, 2024 1:02 PM I74800 JUL 25, 2024 1:02 PM I74900 JUL 25, 2024 1:02 PM I7BC00 JUL 25, 2024 1:02 PM I80200 JUL 25, 2024 1:02 PM I80300 JUL 25, 2024 1:02 PM I80400 JUL 25, 2024 1:02 PM I80700 JUL 25, 2024 1:02 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DIESEL 4 OVERFILL ALARM I80900 JUL 25, 2024 1:02 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUL 25, 2024 1:02 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DIESEL 4 4 OVERFILL ALARM NONE I80A00 JUL 25, 2024 1:02 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 JUL 25, 2024 1:02 PM I80800 JUL 25, 2024 1:02 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS h 9:GROSS COLLECT FAIL h10:GROSS COLLECT FAIL h11:GROSS COLLECT FAIL h12:GROSS COLLECT FAIL h13:GROSS COLLECT FAIL h14:GROSS COLLECT FAIL h15:GROSS COLLECT FAIL h16:GROSS COLLECT FAIL h17:GROSS COLLECT FAIL h18:GROSS COLLECT FAIL h19:GROSS COLLECT FAIL h20:GROSS COLLECT FAIL h21:GROSS COLLECT FAIL h22:GROSS COLLECT FAIL h23:GROSS COLLECT FAIL h24:GROSS COLLECT FAIL h25:GROSS COLLECT FAIL h26:GROSS COLLECT FAIL h27:GROSS COLLECT FAIL h28:GROSS COLLECT FAIL h29:GROSS COLLECT FAIL h30:GROSS COLLECT FAIL h31:GROSS COLLECT FAIL h32:GROSS COLLECT FAIL h33:GROSS COLLECT FAIL h34:GROSS COLLECT FAIL h35:GROSS COLLECT FAIL h36:GROSS COLLECT FAIL h37:GROSS COLLECT FAIL h38:GROSS COLLECT FAIL h39:GROSS COLLECT FAIL h40:GROSS COLLECT FAIL h41:GROSS COLLECT FAIL h42:GROSS COLLECT FAIL h43:GROSS COLLECT FAIL h44:GROSS COLLECT FAIL h45:GROSS COLLECT FAIL h46:GROSS COLLECT FAIL h47:GROSS COLLECT FAIL h48:GROSS COLLECT FAIL h49:GROSS COLLECT FAIL h50:GROSS COLLECT FAIL h51:GROSS COLLECT FAIL h52:GROSS COLLECT FAIL h53:GROSS COLLECT FAIL h54:GROSS COLLECT FAIL h55:GROSS COLLECT FAIL h56:GROSS COLLECT FAIL h57:GROSS COLLECT FAIL h58:GROSS COLLECT FAIL h59:GROSS COLLECT FAIL h60:GROSS COLLECT FAIL h61:GROSS COLLECT FAIL h62:GROSS COLLECT FAIL h63:GROSS COLLECT FAIL h64:GROSS COLLECT FAIL h65:GROSS COLLECT FAIL h66:GROSS COLLECT FAIL h67:GROSS COLLECT FAIL h68:GROSS COLLECT FAIL h69:GROSS COLLECT FAIL h70:GROSS COLLECT FAIL h71:GROSS COLLECT FAIL h72:GROSS COLLECT FAIL h73:GROSS COLLECT FAIL h74:GROSS COLLECT FAIL h75:GROSS COLLECT FAIL h76:GROSS COLLECT FAIL h77:GROSS COLLECT FAIL h78:GROSS COLLECT FAIL h79:GROSS COLLECT FAIL h80:GROSS COLLECT FAIL h81:GROSS COLLECT FAIL h82:GROSS COLLECT FAIL h83:GROSS COLLECT FAIL h84:GROSS COLLECT FAIL h85:GROSS COLLECT FAIL h86:GROSS COLLECT FAIL h87:GROSS COLLECT FAIL h88:GROSS COLLECT FAIL h89:GROSS COLLECT FAIL h90:GROSS COLLECT FAIL h91:GROSS COLLECT FAIL h92:GROSS COLLECT FAIL h93:GROSS COLLECT FAIL h94:GROSS COLLECT FAIL h95:GROSS COLLECT FAIL h96:GROSS COLLECT FAIL h97:GROSS COLLECT FAIL h98:GROSS COLLECT FAIL h99:GROSS COLLECT FAIL h 9:DEGRD COLLECT FAIL h10:DEGRD COLLECT FAIL h11:DEGRD COLLECT FAIL h12:DEGRD COLLECT FAIL h13:DEGRD COLLECT FAIL h14:DEGRD COLLECT FAIL h15:DEGRD COLLECT FAIL h16:DEGRD COLLECT FAIL h17:DEGRD COLLECT FAIL h18:DEGRD COLLECT FAIL h19:DEGRD COLLECT FAIL h20:DEGRD COLLECT FAIL h21:DEGRD COLLECT FAIL h22:DEGRD COLLECT FAIL h23:DEGRD COLLECT FAIL h24:DEGRD COLLECT FAIL h25:DEGRD COLLECT FAIL h26:DEGRD COLLECT FAIL h27:DEGRD COLLECT FAIL h28:DEGRD COLLECT FAIL h29:DEGRD COLLECT FAIL h30:DEGRD COLLECT FAIL h31:DEGRD COLLECT FAIL h32:DEGRD COLLECT FAIL h33:DEGRD COLLECT FAIL h34:DEGRD COLLECT FAIL h35:DEGRD COLLECT FAIL h36:DEGRD COLLECT FAIL h37:DEGRD COLLECT FAIL h38:DEGRD COLLECT FAIL h39:DEGRD COLLECT FAIL h40:DEGRD COLLECT FAIL h41:DEGRD COLLECT FAIL h42:DEGRD COLLECT FAIL h43:DEGRD COLLECT FAIL h44:DEGRD COLLECT FAIL h45:DEGRD COLLECT FAIL h46:DEGRD COLLECT FAIL h47:DEGRD COLLECT FAIL h48:DEGRD COLLECT FAIL h49:DEGRD COLLECT FAIL h50:DEGRD COLLECT FAIL h51:DEGRD COLLECT FAIL h52:DEGRD COLLECT FAIL h53:DEGRD COLLECT FAIL h54:DEGRD COLLECT FAIL h55:DEGRD COLLECT FAIL h56:DEGRD COLLECT FAIL h57:DEGRD COLLECT FAIL h58:DEGRD COLLECT FAIL h59:DEGRD COLLECT FAIL h60:DEGRD COLLECT FAIL h61:DEGRD COLLECT FAIL h62:DEGRD COLLECT FAIL h63:DEGRD COLLECT FAIL h64:DEGRD COLLECT FAIL h65:DEGRD COLLECT FAIL h66:DEGRD COLLECT FAIL h67:DEGRD COLLECT FAIL h68:DEGRD COLLECT FAIL h69:DEGRD COLLECT FAIL h70:DEGRD COLLECT FAIL h71:DEGRD COLLECT FAIL h72:DEGRD COLLECT FAIL h73:DEGRD COLLECT FAIL h74:DEGRD COLLECT FAIL h75:DEGRD COLLECT FAIL h76:DEGRD COLLECT FAIL h77:DEGRD COLLECT FAIL h78:DEGRD COLLECT FAIL h79:DEGRD COLLECT FAIL h80:DEGRD COLLECT FAIL h81:DEGRD COLLECT FAIL h82:DEGRD COLLECT FAIL h83:DEGRD COLLECT FAIL h84:DEGRD COLLECT FAIL h85:DEGRD COLLECT FAIL h86:DEGRD COLLECT FAIL h87:DEGRD COLLECT FAIL h88:DEGRD COLLECT FAIL h89:DEGRD COLLECT FAIL h90:DEGRD COLLECT FAIL h91:DEGRD COLLECT FAIL h92:DEGRD COLLECT FAIL h93:DEGRD COLLECT FAIL h94:DEGRD COLLECT FAIL h95:DEGRD COLLECT FAIL h96:DEGRD COLLECT FAIL h97:DEGRD COLLECT FAIL h98:DEGRD COLLECT FAIL h99:DEGRD COLLECT FAIL h 9:FLOW COLLECT FAIL h10:FLOW COLLECT FAIL h11:FLOW COLLECT FAIL h12:FLOW COLLECT FAIL h13:FLOW COLLECT FAIL h14:FLOW COLLECT FAIL h15:FLOW COLLECT FAIL h16:FLOW COLLECT FAIL h17:FLOW COLLECT FAIL h18:FLOW COLLECT FAIL h19:FLOW COLLECT FAIL h20:FLOW COLLECT FAIL h21:FLOW COLLECT FAIL h22:FLOW COLLECT FAIL h23:FLOW COLLECT FAIL h24:FLOW COLLECT FAIL h25:FLOW COLLECT FAIL h26:FLOW COLLECT FAIL h27:FLOW COLLECT FAIL h28:FLOW COLLECT FAIL h29:FLOW COLLECT FAIL h30:FLOW COLLECT FAIL h31:FLOW COLLECT FAIL h32:FLOW COLLECT FAIL h33:FLOW COLLECT FAIL h34:FLOW COLLECT FAIL h35:FLOW COLLECT FAIL h36:FLOW COLLECT FAIL h37:FLOW COLLECT FAIL h38:FLOW COLLECT FAIL h39:FLOW COLLECT FAIL h40:FLOW COLLECT FAIL h41:FLOW COLLECT FAIL h42:FLOW COLLECT FAIL h43:FLOW COLLECT FAIL h44:FLOW COLLECT FAIL h45:FLOW COLLECT FAIL h46:FLOW COLLECT FAIL h47:FLOW COLLECT FAIL h48:FLOW COLLECT FAIL h49:FLOW COLLECT FAIL h50:FLOW COLLECT FAIL h51:FLOW COLLECT FAIL h52:FLOW COLLECT FAIL h53:FLOW COLLECT FAIL h54:FLOW COLLECT FAIL h55:FLOW COLLECT FAIL h56:FLOW COLLECT FAIL h57:FLOW COLLECT FAIL h58:FLOW COLLECT FAIL h59:FLOW COLLECT FAIL h60:FLOW COLLECT FAIL h61:FLOW COLLECT FAIL h62:FLOW COLLECT FAIL h63:FLOW COLLECT FAIL h64:FLOW COLLECT FAIL h65:FLOW COLLECT FAIL h66:FLOW COLLECT FAIL h67:FLOW COLLECT FAIL h68:FLOW COLLECT FAIL h69:FLOW COLLECT FAIL h70:FLOW COLLECT FAIL h71:FLOW COLLECT FAIL h72:FLOW COLLECT FAIL h73:FLOW COLLECT FAIL h74:FLOW COLLECT FAIL h75:FLOW COLLECT FAIL h76:FLOW COLLECT FAIL h77:FLOW COLLECT FAIL h78:FLOW COLLECT FAIL h79:FLOW COLLECT FAIL h80:FLOW COLLECT FAIL h81:FLOW COLLECT FAIL h82:FLOW COLLECT FAIL h83:FLOW COLLECT FAIL h84:FLOW COLLECT FAIL h85:FLOW COLLECT FAIL h86:FLOW COLLECT FAIL h87:FLOW COLLECT FAIL h88:FLOW COLLECT FAIL h89:FLOW COLLECT FAIL h90:FLOW COLLECT FAIL h91:FLOW COLLECT FAIL h92:FLOW COLLECT FAIL h93:FLOW COLLECT FAIL h94:FLOW COLLECT FAIL h95:FLOW COLLECT FAIL h96:FLOW COLLECT FAIL h97:FLOW COLLECT FAIL h98:FLOW COLLECT FAIL h99:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 3:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUL 25, 2024 1:02 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 25, 2024 1:02 PM I72300 JUL 25, 2024 1:02 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNKNOWN 02 F.M DISP 1-2 AIR FLOW METER 03 F.M DISP 3-4 AIR FLOW METER 04 F.M DISP 5-6 AIR FLOW METER 05 F.M DISP 7-8 AIR FLOW METER 06 V.P. 1-2 VAPOR PRESSURE 07 UNKNOWN 08 VP 1-2 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 25, 2024 1:02 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 25, 2024 1:02 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 25, 2024 1:02 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 VAPOR PROCESSOR TYPE NONE IV4700 JUL 25, 2024 1:02 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 25, 2024 1:03 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ACCEPT HIGH ORVR: YES IV4A00 JUL 25, 2024 1:03 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND3 02 02 02 01 UU BLEND3 03 03 03 02 UU BLEND3 04 04 04 02 UU BLEND3 05 05 05 03 UU BLEND3 06 06 06 03 UU BLEND3 07 07 07 04 UU BLEND3 08 08 08 04 UU BLEND3 IV4B00 JUL 25, 2024 1:03 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 03/01 02/01 09/01 xx/xx 02 01 03/02 02/02 09/02 xx/xx 03 02 03/03 02/03 09/03 xx/xx 04 02 03/04 02/04 09/04 xx/xx 05 03 03/05 02/05 09/05 xx/xx 06 03 03/06 02/06 09/06 xx/xx 07 04 03/07 02/07 09/07 xx/xx 08 04 03/08 02/08 09/08 xx/xx IV4900 JUL 25, 2024 1:03 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 25, 2024 1:03 PM ISD VERSION: 01.07 Responses Received: I10200 JUL 25, 2024 1:03 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39572 39516 2 4 PROBE / G.T. 163706 163628 3 INTERSTITIAL BD 202336 201201 4 INTERSTITIAL BD 201545 201593 5 UNUSED 4949561 15000000 6 UNUSED 4943889 4538851 7 UNUSED 4944139 4579287 8 UNUSED 4942950 4544616 9 STP SENSE BOARD 33207 33157 10 UNUSED 4944389 4558412 11 RELAY BOARD 14993 14956 12 UNUSED 4944911 4577796 13 UNUSED 4944223 15000000 14 UNUSED 4943826 4539725 15 UNUSED 4947267 4622794 16 UNUSED 4945182 4599588 COMM 1 RS232 SERIAL BD 15014 14999 COMM 2 RS232 SERIAL BD 15035 14999 COMM 3 ELEC DISP INT. 101659 100625 COMM 4 UNUSED 4947059 4591163 COMM 5 UNUSED 4945474 4625370 COMM 6 UNUSED 4946183 4636012 I90200 JUL 25, 2024 1:03 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 25, 2024 1:03 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-15-24 3:03PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-15-24 3:03PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM ALARM 7-15-24 3:03PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-15-24 3:03PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-15-24 3:03PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-15-24 2:53PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-15-24 2:53PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-15-24 2:43PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-15-24 2:39PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-15-24 2:38PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-15-24 2:36PM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-15-24 2:23PM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-15-24 2:22PM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-15-24 2:21PM L13 ANNULAR T1 87 ANN FUEL ALARM CLEAR 7-15-24 2:21PM L13 ANNULAR T1 87 ANN FUEL ALARM ALARM 7-15-24 2:21PM L13 ANNULAR T1 87 ANN FUEL ALARM CLEAR 7-15-24 2:21PM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-15-24 2:21PM L13 ANNULAR T1 87 ANN FUEL ALARM ALARM 7-15-24 2:20PM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-15-24 2:19PM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-15-24 2:19PM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-15-24 2:17PM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-15-24 2:17PM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-15-24 2:17PM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-15-24 2:17PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-15-24 2:16PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-15-24 2:16PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-15-24 2:15PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-15-24 2:15PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-15-24 2:14PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 7-15-24 2:13PM I11200 JUL 25, 2024 1:04 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK PNL DELIVERY NEEDED CLEAR 7-23-24 11:18PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-23-24 8:15PM OTHER ISD GROSS PRES WARN CLEAR 7-22-24 8:55AM OTHER ISD GROSS PRES WARN ALARM 7-21-24 10:02AM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-17-24 11:00AM T 3 TANK PNL DELIVERY NEEDED ALARM 7-17-24 10:29AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 7-07-24 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 7-04-24 10:01AM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-03-24 6:45PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-03-24 12:33PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 6-28-24 5:08PM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 6-28-24 5:08PM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 6-28-24 10:02AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 6-25-24 10:02AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 6-24-24 12:28PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 6-20-24 2:54PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 6-20-24 8:01AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 6-19-24 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 6-19-24 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 6-18-24 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 6-17-24 10:01AM T 3 TANK PNL DELIVERY NEEDED CLEAR 6-15-24 6:22PM SYSTEM PRINTER ERROR CLEAR 6-15-24 6:18PM SYSTEM PAPER OUT CLEAR 6-15-24 6:18PM SYSTEM PRINTER ERROR ALARM 6-15-24 6:17PM SYSTEM PAPER OUT ALARM 6-15-24 6:17PM T 3 TANK PNL DELIVERY NEEDED ALARM 6-15-24 3:17PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 6-14-24 10:00AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 6-13-24 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 6-12-24 10:01AM SYSTEM PRINTER ERROR CLEAR 6-11-24 7:07AM SYSTEM PRINTER ERROR ALARM 6-11-24 7:06AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:29AM SYSTEM PAPER OUT ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:29AM SYSTEM PAPER OUT ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:28AM SYSTEM PAPER OUT ALARM 6-10-24 11:28AM SYSTEM PRINTER ERROR CLEAR 6-01-24 11:14AM SYSTEM PAPER OUT CLEAR 6-01-24 11:14AM I20600 JUL 25, 2024 1:04 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 HIGH WATER ALARM FEB 29, 2024 9:48 AM FEB 29, 2024 2:27 AM OVERFILL ALARM FEB 29, 2024 2:26 AM FEB 29, 2024 2:16 AM JUL 2, 2023 12:44 PM LOW PRODUCT ALARM DEC 30, 2023 7:52 AM SUDDEN LOSS ALARM JUL 13, 2024 1:04 AM JUL 13, 2024 12:28 AM MAY 22, 2024 12:16 AM INVALID FUEL LEVEL FEB 29, 2024 9:44 AM FEB 29, 2024 2:26 AM FEB 29, 2024 2:24 AM PROBE OUT FEB 29, 2024 9:54 AM FEB 29, 2024 9:51 AM FEB 29, 2024 9:04 AM HIGH WATER WARNING FEB 29, 2024 9:48 AM FEB 29, 2024 2:27 AM DELIVERY NEEDED MAY 13, 2024 8:41 PM FEB 29, 2024 9:57 AM FEB 29, 2024 2:24 AM LOW TEMP WARNING FEB 29, 2024 8:09 AM FEB 29, 2024 5:49 AM FEB 29, 2024 2:31 AM TANK 2 UNL 2 OVERFILL ALARM OCT 12, 2023 1:40 AM JUL 13, 2023 3:31 PM JUN 2, 2023 2:59 AM TANK 3 PNL DELIVERY NEEDED JUL 23, 2024 8:15 PM JUL 17, 2024 10:29 AM JUL 3, 2024 12:33 PM TANK 4 DIESEL OVERFILL ALARM AUG 28, 2023 1:07 AM DELIVERY NEEDED JUN 20, 2024 8:01 AM JAN 26, 2024 2:04 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 25, 2024 1:04 PM I30200 JUL 25, 2024 1:04 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:53 PM FUEL ALARM FEB 18, 2024 8:07 PM FUEL ALARM 3 DIESEL STP JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:13 PM FUEL ALARM JUN 6, 2024 2:42 PM FUEL ALARM 4 DIESEL ANN JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:39 PM FUEL ALARM JUL 15, 2024 2:36 PM FUEL ALARM 5 REG2 STP JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:12 PM FUEL ALARM JUL 15, 2024 2:12 PM FUEL ALARM 6 REG 2 ANN JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:21 PM FUEL ALARM JUL 18, 2023 4:15 PM SENSOR OUT ALARM 7 SUPER STP JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:13 PM FUEL ALARM JUL 18, 2023 4:15 PM SENSOR OUT ALARM 8 SUPER ANN JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:22 PM FUEL ALARM JUL 18, 2023 4:15 PM SENSOR OUT ALARM 9 DISP 1-2 JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:15 PM FUEL ALARM JUL 18, 2023 4:15 PM SENSOR OUT ALARM 10 DISP 7-8 JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:19 PM FUEL ALARM JUL 18, 2023 4:15 PM SENSOR OUT ALARM 11 DISP 5-6 JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:16 PM FUEL ALARM FEB 6, 2024 11:42 PM FUEL ALARM 12 DISP 3-4 JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:17 PM FUEL ALARM JUL 15, 2024 2:17 PM FUEL ALARM 13 T1 87 ANN JUL 15, 2024 3:03 PM SENSOR OUT ALARM JUL 15, 2024 2:21 PM FUEL ALARM JUL 15, 2024 2:20 PM FUEL ALARM I31600 JUL 25, 2024 1:04 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 JUN 19, 2024 1:14 PM COMMUNICATION ALARM 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 25, 2024 1:04 PM I40300 JUL 25, 2024 1:04 PM I34200 JUL 25, 2024 1:04 PM I34700 JUL 25, 2024 1:04 PM IV0100 JUL 25, 2024 1:04 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 24-07-21 10:02:17 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.64 24-07-06 10:01:09 A/L RATIO DEGRADATION FP 1 BLEND3 0.81 24-07-05 10:01:10 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 24-07-04 10:01:40 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 24-06-28 10:02:18 A/L RATIO DEGRADATION FP 2 BLEND3 0.74 24-06-28 10:02:18 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 24-06-27 10:02:46 A/L RATIO DEGRADATION FP 2 BLEND3 0.76 24-06-26 10:02:40 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 24-06-25 10:02:25 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 24-06-24 10:02:29 A/L RATIO DEGRADATION FP 1 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-19 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 1.35 22-05-25 10:02:51 A/L RATIO DEGRADATION FP 5 BLEND3 0.70 22-04-30 10:02:15 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 24-07-22 10:02:32 READINESS ISD:PP EVR:PP ISD & EVR READY 24-07-22 08:55:34 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 24-07-21 19:31:30 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-07-21 19:31:30 ISD STARTUP 24-07-21 19:31:19 ISD SHUTDOWN 24-07-16 10:01:45 READINESS ISD:PP EVR:PP ISD & EVR READY 24-07-15 15:04:56 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-07-15 15:04:56 ISD STARTUP 24-07-15 15:04:51 ISD SHUTDOWN 24-06-28 17:08:28 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED Responses Received: I10200 JUL 25, 2024 5:22 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39572 39567 2 4 PROBE / G.T. 163706 164028 3 INTERSTITIAL BD 202336 203056 4 INTERSTITIAL BD 201545 202408 5 UNUSED 4949561 4504222 6 UNUSED 4943889 4427456 7 UNUSED 4944139 4436608 8 UNUSED 4942950 4499234 9 STP SENSE BOARD 33207 33175 10 UNUSED 4944389 4436150 11 RELAY BOARD 14993 14991 12 UNUSED 4944911 4482523 13 UNUSED 4944223 4409667 14 UNUSED 4943826 4451981 15 UNUSED 4947267 4450523 16 UNUSED 4945182 4512536 COMM 1 RS232 SERIAL BD 15014 15012 COMM 2 RS232 SERIAL BD 15035 15034 COMM 3 ELEC DISP INT. 101659 101363 COMM 4 UNUSED 4947059 4481170 COMM 5 UNUSED 4945474 4560768 COMM 6 UNUSED 4946183 4568652 I90200 JUL 25, 2024 5:22 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 25, 2024 5:22 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-25-24 4:53PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-25-24 4:53PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM CLEAR 7-25-24 4:52PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-25-24 4:52PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-25-24 4:52PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-25-24 4:52PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-25-24 4:52PM L13 ANNULAR T1 87 ANN SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-25-24 4:52PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-25-24 4:48PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-25-24 4:48PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-25-24 4:46PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 7-25-24 4:46PM L 7 STP SUMP SUPER STP FUEL ALARM CLEAR 7-25-24 4:45PM L 7 STP SUMP SUPER STP FUEL ALARM ALARM 7-25-24 4:45PM L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 7-25-24 4:45PM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 7-25-24 4:44PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-25-24 4:39PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-25-24 4:38PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-25-24 4:38PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-25-24 4:38PM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-25-24 4:37PM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-25-24 4:37PM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-25-24 4:36PM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-25-24 4:36PM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-25-24 4:35PM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-25-24 4:35PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-25-24 4:34PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-25-24 4:34PM L13 ANNULAR T1 87 ANN FUEL ALARM CLEAR 7-25-24 4:33PM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-25-24 4:33PM L13 ANNULAR T1 87 ANN FUEL ALARM ALARM 7-25-24 4:33PM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-25-24 4:33PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-15-24 3:04PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-15-24 3:04PM I11200 JUL 25, 2024 5:22 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK PNL DELIVERY NEEDED CLEAR 7-23-24 11:18PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-23-24 8:15PM OTHER ISD GROSS PRES WARN CLEAR 7-22-24 8:55AM OTHER ISD GROSS PRES WARN ALARM 7-21-24 10:02AM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-17-24 11:00AM T 3 TANK PNL DELIVERY NEEDED ALARM 7-17-24 10:29AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 7-07-24 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 7-04-24 10:01AM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-03-24 6:45PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-03-24 12:33PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 6-28-24 5:08PM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 6-28-24 5:08PM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 6-28-24 10:02AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 6-25-24 10:02AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 6-24-24 12:28PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 6-20-24 2:54PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 6-20-24 8:01AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 6-19-24 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 6-19-24 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 6-18-24 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 6-17-24 10:01AM T 3 TANK PNL DELIVERY NEEDED CLEAR 6-15-24 6:22PM SYSTEM PRINTER ERROR CLEAR 6-15-24 6:18PM SYSTEM PAPER OUT CLEAR 6-15-24 6:18PM SYSTEM PRINTER ERROR ALARM 6-15-24 6:17PM SYSTEM PAPER OUT ALARM 6-15-24 6:17PM T 3 TANK PNL DELIVERY NEEDED ALARM 6-15-24 3:17PM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 6-14-24 10:00AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 6-13-24 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 6-12-24 10:01AM SYSTEM PRINTER ERROR CLEAR 6-11-24 7:07AM SYSTEM PRINTER ERROR ALARM 6-11-24 7:06AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:29AM SYSTEM PAPER OUT ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:29AM SYSTEM PAPER OUT ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:29AM SYSTEM PRINTER ERROR CLEAR 6-10-24 11:29AM SYSTEM PAPER OUT CLEAR 6-10-24 11:29AM SYSTEM PRINTER ERROR ALARM 6-10-24 11:28AM SYSTEM PAPER OUT ALARM 6-10-24 11:28AM SYSTEM PRINTER ERROR CLEAR 6-01-24 11:14AM SYSTEM PAPER OUT CLEAR 6-01-24 11:14AM I20600 JUL 25, 2024 5:22 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 HIGH WATER ALARM FEB 29, 2024 9:48 AM FEB 29, 2024 2:27 AM OVERFILL ALARM FEB 29, 2024 2:26 AM FEB 29, 2024 2:16 AM JUL 2, 2023 12:44 PM LOW PRODUCT ALARM DEC 30, 2023 7:52 AM SUDDEN LOSS ALARM JUL 13, 2024 1:04 AM JUL 13, 2024 12:28 AM MAY 22, 2024 12:16 AM INVALID FUEL LEVEL FEB 29, 2024 9:44 AM FEB 29, 2024 2:26 AM FEB 29, 2024 2:24 AM PROBE OUT FEB 29, 2024 9:54 AM FEB 29, 2024 9:51 AM FEB 29, 2024 9:04 AM HIGH WATER WARNING FEB 29, 2024 9:48 AM FEB 29, 2024 2:27 AM DELIVERY NEEDED MAY 13, 2024 8:41 PM FEB 29, 2024 9:57 AM FEB 29, 2024 2:24 AM LOW TEMP WARNING FEB 29, 2024 8:09 AM FEB 29, 2024 5:49 AM FEB 29, 2024 2:31 AM TANK 2 UNL 2 OVERFILL ALARM OCT 12, 2023 1:40 AM JUL 13, 2023 3:31 PM JUN 2, 2023 2:59 AM TANK 3 PNL DELIVERY NEEDED JUL 23, 2024 8:15 PM JUL 17, 2024 10:29 AM JUL 3, 2024 12:33 PM TANK 4 DIESEL OVERFILL ALARM AUG 28, 2023 1:07 AM DELIVERY NEEDED JUN 20, 2024 8:01 AM JAN 26, 2024 2:04 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 25, 2024 5:22 PM I30200 JUL 25, 2024 5:22 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:48 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 3 DIESEL STP JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:46 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 4 DIESEL ANN JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:34 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 5 REG2 STP JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:44 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 6 REG 2 ANN JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:33 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 7 SUPER STP JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:45 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 8 SUPER ANN JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:33 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 9 DISP 1-2 JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:38 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 10 DISP 7-8 JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:36 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 11 DISP 5-6 JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:38 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 12 DISP 3-4 JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:37 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM 13 T1 87 ANN JUL 25, 2024 4:52 PM SENSOR OUT ALARM JUL 25, 2024 4:33 PM FUEL ALARM JUL 15, 2024 3:03 PM SENSOR OUT ALARM I31600 JUL 25, 2024 5:23 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 JUN 19, 2024 1:14 PM COMMUNICATION ALARM 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 25, 2024 5:23 PM I40300 JUL 25, 2024 5:23 PM I34200 JUL 25, 2024 5:23 PM I34700 JUL 25, 2024 5:23 PM IV0100 JUL 25, 2024 5:23 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 24-07-21 10:02:17 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.64 24-07-06 10:01:09 A/L RATIO DEGRADATION FP 1 BLEND3 0.81 24-07-05 10:01:10 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 24-07-04 10:01:40 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 24-06-28 10:02:18 A/L RATIO DEGRADATION FP 2 BLEND3 0.74 24-06-28 10:02:18 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 24-06-27 10:02:46 A/L RATIO DEGRADATION FP 2 BLEND3 0.76 24-06-26 10:02:40 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 24-06-25 10:02:25 A/L RATIO DEGRADATION FP 2 BLEND3 0.78 24-06-24 10:02:29 A/L RATIO DEGRADATION FP 1 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 24-06-19 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 1.35 22-05-25 10:02:51 A/L RATIO DEGRADATION FP 5 BLEND3 0.70 22-04-30 10:02:15 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 24-07-25 16:53:19 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-07-25 16:53:19 ISD STARTUP 24-07-25 16:53:13 ISD SHUTDOWN 24-07-25 16:51:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-07-25 16:51:51 ISD STARTUP 24-07-25 16:51:31 ISD SHUTDOWN 24-07-22 10:02:32 READINESS ISD:PP EVR:PP ISD & EVR READY 24-07-22 08:55:34 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 24-07-21 19:31:30 READINESS ISD:PP EVR:NN EVR READINESS PENDING 24-07-21 19:31:30 ISD STARTUP