HomeMy WebLinkAboutFMC 2024Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10134244 08/07/2024 Jaco #3360 Farrell's Fastrip 6401 White Lane Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/2025 Veeder Root - C33847 07/24/2025 Vaporless Manufacturing LLC #5346 03/14/2025 08/07/2024 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS350 336.02 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 208 Unleaded STP L3 208 Unleaded Fill L4 208 Premium STP L5 208 Premium Fill L6 303 Premium Annular L7 208 Diesel STP L9 303 Diesel Annular L10 208 Dispenser 1/2 L11 208 Dispenser 3/4 L12 208 Dispenser 5/6 L13 208 Dispenser 7/8 L14 303 Unleaded Annular L15 208 Diesel Fill Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 Unleaded T2 FX1V 91 Premium T3 FX1DV Diesel Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 08/07/2024 EXISTING BUILDING 78L13 12,000 GALLON87 UNLEADED 34L11 56L1212L10 STPL1 AL2 12,000 GALLONPREMIUM 12,000 GALLONDIESEL FV FV F AL5 AL16 STPL4 STPL7 L3 L6 L8 NOPARKING NOPARKING DUMPSTERDRAINAGE WAYDRAINAGE WAY DRAINAGE WAYDRAINAGE WAY DRAINAGE WAY DRAINAGE WAYDUMPSTER H W W G WHITE LN. PROPERTY LINE ASHE RD.PRICE SIGNPLAZA SIGNPRICE SIGN N PROPERTY LINE LEGEND L1 87 STP L2 87 ANNULAR L3 87 FILL L4 91 STP L5 91 ANNULAR L6 91 FILL L7 DSL STP L8 DSL FILL L10 UDC 1 - 2 L11 UDC 3 - 4 L12 UDC 5 - 6 L13 UDC 7 - 8 L16 DSL ANNULAR 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER SHUT OFF HEALY CAS EVACUATION MEETING POINT AUTOMATIC TANK GAUGE UST ELECTRICAL PANEL CIRCUIT BREAKER AIR AND WATER DISPENSER FIRE PREVENTION SYSTEM G A H P V W SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 1"=20'-0" INCHES012 SHEET SIZE 22 X 34 6401 WHITE LN. BAKERSFIELD, CA 93309 PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACITILY ID 15-021-003021 CERS ID 10134202 FASTRIP #3360 6401 WHITE LN. BAKERSFIELD, CA 93309 01/16/17 REV.ASHE RD.WHITE LN. APPENDIX C-10 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU$GGUHVV$GGUHVV&LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH)DFLOLW\,'3KRQH7HVWLQJ&RPSDQ\3KRQH7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH3URGXFW*UDGH'LVSHQVHU,'    6KHDU9DOYH7\SH 3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\DQFKRUHGWRWKHGLVSHQVHUER[IUDPHRUGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHVKHDUVHFWLRQSRVLWLRQHGEHWZHHQóLQFKDERYHRUEHORZWKHWRSVXUIDFHRIWKHGLVSHQVHULVODQG"<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R<HV1R,VWKHOHYHUDUPIUHHWRPRYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$'RHVWKHOHYHUDUPVQDSVKXWWKHSRSSHWYDOYH"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$&DQDQ\SURGXFWEHGLVSHQVHGZKHQWKHSURGXFWVKHDUYDOYHLVFORVHG"<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$<HV1R1$$´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUHTest Results3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLOComments:7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1ZHVWFR//&  Jaco #3360 Farrell's Fastrip6401 White LaneBakersfield101342443/47/8MPDMPDMPDMPD1/25/6ProductProductProductProductMark Fisher Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10134244 08/07/2024 Jaco #3360 Farrell's Fastrip 6401 White Lane Bakersfield 93309 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Mark Fisher 1073967 10278702 03/10/2025 FFS - 1022293714 11/10/2024 PEI1200, 1 hour hydrostatic test All Spill Buckets 08/07/2024 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. 87 Phil-Tite 91 Phil-Tite Diesel Phil-Tite JACO #3360 SYSTEM SETUP Responses Received: 200 FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 AUG 7, 2024 10:02 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 3076 28.46 0.0 88.4 8606 2 PNL 7165 54.24 0.8 88.1 4517 3 DIESEL 3448 30.93 0.0 89.0 8234 I90500 AUG 7, 2024 10:02 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 AUG 7, 2024 10:02 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 7, 2024 10:02 AM SHIFT TIME 1 : 7:00 AM I50202 AUG 7, 2024 10:02 AM SHIFT TIME 2 : DISABLED I50203 AUG 7, 2024 10:02 AM SHIFT TIME 3 : DISABLED I50204 AUG 7, 2024 10:02 AM SHIFT TIME 4 : DISABLED I54600 AUG 7, 2024 10:02 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 7, 2024 10:02 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 7, 2024 10:02 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 7, 2024 10:02 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 7, 2024 10:02 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 7, 2024 10:02 AM PRINT TC VOLUMES ENABLED I50E00 AUG 7, 2024 10:02 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 7, 2024 10:02 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 7, 2024 10:02 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 7, 2024 10:02 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 7, 2024 10:02 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 AUG 7, 2024 10:02 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 7, 2024 10:02 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 7, 2024 10:02 AM TANK CHART SECURITY DISABLED I5BD00 AUG 7, 2024 10:02 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 7, 2024 10:02 AM MASS/DENSITY DISABLED I88101 AUG 7, 2024 10:02 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 AUG 7, 2024 10:02 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 7, 2024 10:02 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 AUG 7, 2024 10:02 AM I88105 AUG 7, 2024 10:02 AM I88106 AUG 7, 2024 10:02 AM I52000 AUG 7, 2024 10:02 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 7, 2024 DISABLED 2 ON DATE ??? 7, 2024 DISABLED 3 ON DATE ??? 7, 2024 DISABLED 4 ON DATE ??? 7, 2024 DISABLED 5 ON DATE ??? 7, 2024 DISABLED 6 ON DATE ??? 7, 2024 DISABLED 7 ON DATE ??? 7, 2024 DISABLED 8 ON DATE ??? 7, 2024 DISABLED I60100 AUG 7, 2024 10:02 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL ON 2 PNL ON 3 DIESEL ON 4 OFF I60200 AUG 7, 2024 10:02 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 2 PNL 3 DIESEL 4 I60300 AUG 7, 2024 10:02 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 2 PNL 2 3 DIESEL 3 4 4 I60900 AUG 7, 2024 10:02 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 0.000700 2 PNL 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 AUG 7, 2024 10:02 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 92.00 2 PNL 92.00 3 DIESEL 92.00 4 0.00 I60A00 AUG 7, 2024 10:02 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 PT 11682 2 PNL 1 PT 11682 3 DIESEL 1 PT 11682 4 1 PT 0 I60400 AUG 7, 2024 10:02 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 11682 2 PNL 11682 3 DIESEL 11682 4 0 I60500 AUG 7, 2024 10:02 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 11682 0 0 0 2 PNL 11682 0 0 0 3 DIESEL 11682 0 0 0 4 0 0 0 0 I60600 AUG 7, 2024 10:02 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 PNL 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 11682 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 7, 2024 10:02 AM TANK PRODUCT LABEL METER DATA 1 UNL NO 2 PNL NO 3 DIESEL NO 4 NO I62F00 AUG 7, 2024 10:02 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 4.0 IN. 2 PNL 4.0 IN. 3 DIESEL 4.0 IN. I62700 AUG 7, 2024 10:02 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 2.0 2 PNL 2.0 3 DIESEL 2.0 I64200 AUG 7, 2024 10:02 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL LOW 2 PNL LOW 3 DIESEL LOW I62400 AUG 7, 2024 10:02 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 3.0 2 PNL 3.0 3 DIESEL 3.0 I62800 AUG 7, 2024 10:02 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 11682 2 PNL 11682 3 DIESEL 11682 4 0 I62300 AUG 7, 2024 10:02 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 10800 2 PNL 10800 3 DIESEL 10800 4 0 I62200 AUG 7, 2024 10:02 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 11400 2 PNL 11400 3 DIESEL 11400 4 0 I62900 AUG 7, 2024 10:02 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1800 2 PNL 1800 3 DIESEL 1800 4 0 I62100 AUG 7, 2024 10:02 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 500 2 PNL 500 3 DIESEL 500 4 0 I62600 AUG 7, 2024 10:03 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 PNL 99 3 DIESEL 99 4 99 I62500 AUG 7, 2024 10:03 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 PNL 99 3 DIESEL 99 4 99 I60800 AUG 7, 2024 10:03 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 8.00 2 PNL 6.00 3 DIESEL 10.00 4 0.00 I60B00 AUG 7, 2024 10:03 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 7, 2024 10:03 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 0.00 2 PNL 0.00 3 DIESEL 0.00 4 0.00 I61200 AUG 7, 2024 10:03 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL NONE NONE 2 PNL NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 AUG 7, 2024 10:03 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 120 2 PNL 120 3 DIESEL 120 4 0 I62A00 AUG 7, 2024 10:03 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 120 2 PNL 120 3 DIESEL 120 4 0 I62C00 AUG 7, 2024 10:03 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL STANDARD 2 PNL STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 AUG 7, 2024 10:03 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 7, 2024 10:03 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL OFF OFF 2 PNL OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 AUG 7, 2024 10:03 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL OFF 2 PNL OFF 3 DIESEL OFF 4 OFF I63200 AUG 7, 2024 10:03 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL OFF 2 PNL OFF 3 DIESEL OFF 4 OFF I61000 AUG 7, 2024 10:03 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 2 PNL 1 3 DIESEL 1 4 1 I63A00 AUG 7, 2024 10:03 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 10.00% 2 PNL 10.00% 3 DIESEL 10.00% 4 10.00% I61100 AUG 7, 2024 10:03 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK MAR 22, 2011 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 7, 2024 10:03 AM CSLD PROBABLITY OF DETECTION I61400 AUG 7, 2024 10:03 AM CSLD CLIMATE FACTOR I61600 AUG 7, 2024 10:03 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL IMMEDIATE 2 PNL IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 AUG 7, 2024 10:03 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL DISABLED 2 PNL DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 AUG 7, 2024 10:03 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 7, 2024 10:03 AM CSLD REPORT ONLY I62B00 AUG 7, 2024 10:03 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL ??? 0, 0 2 PNL ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 AUG 7, 2024 10:03 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 7, 2024 10:03 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 0 2 PNL 0 3 DIESEL 0 4 0 I63500 AUG 7, 2024 10:03 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 2 PNL 1 3 DIESEL 1 4 1 I63900 AUG 7, 2024 10:03 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL END FACTOR: NONE 2 PNL END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 AUG 7, 2024 10:03 AM I77700 AUG 7, 2024 10:03 AM I77800 AUG 7, 2024 10:03 AM I78C00 AUG 7, 2024 10:03 AM I78300 AUG 7, 2024 10:03 AM I78F00 AUG 7, 2024 10:03 AM I78700 AUG 7, 2024 10:03 AM I70200 AUG 7, 2024 10:03 AM LIQUID LABEL DEVICE LABEL 1 UNL STP 2 UNL ANN 3 UNL FILL 4 PNL STP 5 PNL FILL 6 PNL ANN 7 DIE STP 8 DIE FILL 9 DIE ANN 10 DIS 1-2 11 DIS 3-4 12 DIS 5-6 13 DIS 7-8 14 UNL ANN 15 DSL FILL 16 DIE ANN I70300 AUG 7, 2024 10:03 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL STP TRI-STATE (SINGLE FLOAT) 2 UNL ANN DUAL POINT HYDROSTATIC 3 UNL FILL TRI-STATE (SINGLE FLOAT) 4 PNL STP TRI-STATE (SINGLE FLOAT) 5 PNL FILL TRI-STATE (SINGLE FLOAT) 6 PNL ANN DUAL POINT HYDROSTATIC 7 DIE STP TRI-STATE (SINGLE FLOAT) 8 DIE FILL TRI-STATE (SINGLE FLOAT) 9 DIE ANN DUAL POINT HYDROSTATIC 10 DIS 1-2 TRI-STATE (SINGLE FLOAT) 11 DIS 3-4 TRI-STATE (SINGLE FLOAT) 12 DIS 5-6 TRI-STATE (SINGLE FLOAT) 13 DIS 7-8 TRI-STATE (SINGLE FLOAT) 14 UNL ANN DUAL POINT HYDROSTATIC 15 DSL FILL TRI-STATE (SINGLE FLOAT) 16 DIE ANN DUAL POINT HYDROSTATIC I70400 AUG 7, 2024 10:03 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL STP STP SUMP 2 UNL ANN ANNULAR SPACE 3 UNL FILL OTHER SENSORS 4 PNL STP STP SUMP 5 PNL FILL OTHER SENSORS 6 PNL ANN ANNULAR SPACE 7 DIE STP STP SUMP 8 DIE FILL OTHER SENSORS 9 DIE ANN ANNULAR SPACE 10 DIS 1-2 DISPENSER PAN 11 DIS 3-4 DISPENSER PAN 12 DIS 5-6 DISPENSER PAN 13 DIS 7-8 DISPENSER PAN 14 UNL ANN ANNULAR SPACE 15 DSL FILL OTHER SENSORS 16 DIE ANN ANNULAR SPACE I74200 AUG 7, 2024 10:03 AM I74300 AUG 7, 2024 10:03 AM I74400 AUG 7, 2024 10:03 AM I74700 AUG 7, 2024 10:03 AM I74800 AUG 7, 2024 10:03 AM I74900 AUG 7, 2024 10:03 AM I7BC00 AUG 7, 2024 10:03 AM I80200 AUG 7, 2024 10:03 AM I80300 AUG 7, 2024 10:03 AM I80400 AUG 7, 2024 10:03 AM I80700 AUG 7, 2024 10:03 AM RELAY LABEL DEVICE LABEL 1 UNL 2 PNL 3 DSL 4 OVERFILL I80900 AUG 7, 2024 10:03 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL NORMALLY CLOSED 2 PNL NORMALLY CLOSED 3 DSL NORMALLY CLOSED 4 OVERFILL NORMALLY OPEN I80B00 AUG 7, 2024 10:03 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 2 PNL 2 3 DSL 3 4 OVERFILL 1 I80A00 AUG 7, 2024 10:03 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL STANDARD 2 PNL STANDARD 3 DSL STANDARD 4 OVERFILL STANDARD I80C00 AUG 7, 2024 10:03 AM I80800 AUG 7, 2024 10:03 AM RELAY SETUP REPORT R 1:UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 1:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 1:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 4:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 4:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 4:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 7:SHORT ALARM L10:SHORT ALARM L12:SHORT ALARM R 4:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: 1 IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 AUG 7, 2024 10:04 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 7, 2024 10:04 AM I72300 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 VP SENSOR DIS 3-4 VAPOR PRESSURE 02 FM DIS 1-2 AIR FLOW METER 03 FM DIS 3-4 AIR FLOW METER 04 FM DIS 5-6 AIR FLOW METER 05 FM DIS 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 VAPOR PROCESSOR TYPE NONE IV4700 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 ASSESSMENT TIME START TIME: 10:01 AM TIME DELAY MINUTES: 1 IV5200 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 ACCEPT HIGH ORVR: NO IV4A00 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 7, 2024 10:04 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 7, 2024 10:04 AM ISD VERSION: 01.07 JACO #3360 ALARM HISTORY BEFORE: Responses Received: I10200 AUG 7, 2024 10:00 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39576 39506 2 4 PROBE / G.T. 164189 164101 3 INTERSTITIAL BD 202921 202716 4 INTERSTITIAL BD 202609 202524 5 UNUSED 9839353 9805355 6 UNUSED 9834213 9803350 7 UNUSED 9832507 9802359 8 UNUSED 9831816 9802543 9 STP SENSE BOARD 33074 33074 10 RELAY BOARD 15053 15030 11 UNUSED 9835996 9805317 12 UNUSED 9830763 9803104 13 UNUSED 9836987 9805824 14 UNUSED 9826200 9806931 15 UNUSED 9830072 9794576 16 UNUSED 9824655 9804165 COMM 1 RS232 SERIAL BD 15030 15030 COMM 2 RS232 SERIAL BD 15099 15099 COMM 3 ELEC DISP INT. 101796 101775 COMM 4 UNUSED 9842657 9806032 COMM 5 UNUSED 9829519 9803727 COMM 6 UNUSED 9828274 9801099 I90200 AUG 7, 2024 10:00 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 7, 2024 10:00 AM FASTRIP 6401 WHITE LANE BAKERSFIELD,CA 93309 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 ANNULAR PNL ANN HIGH LIQUID ALARM ALARM 8-06-24 9:13PM L12 DISP PAN DIS 5-6 FUEL ALARM CLEAR 8-01-24 9:52AM L12 DISP PAN DIS 5-6 FUEL ALARM ALARM 8-01-24 9:37AM L 7 STP SUMP DIE STP SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L 3 OTHER UNL FILL SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L 4 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L10 DISP PAN DIS 1-2 SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L15 OTHER DSL FILL SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L 5 OTHER PNL FILL SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L14 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L12 DISP PAN DIS 5-6 SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L11 DISP PAN DIS 3-4 SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L 9 ANNULAR DIE ANN SENSOR OUT ALARM CLEAR 8-01-24 9:35AM L13 DISP PAN DIS 7-8 SENSOR OUT ALARM CLEAR 8-01-24 9:35AM