Loading...
HomeMy WebLinkAboutOPI 2024 INSTALLATION Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ☒ Installation ☐ Repair ☐ 36 Month 1. FACILITY INFORMATION CERS ID 10953907 Inspection Date 8/19/2024 Facility Name Loves Travel stop #830 Facility Address 1500 Taft HWY City Bakersfield ZIP Code 93307 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection B&T SERVICE STATION CONTRACTORS Phone (805)929-8944 Mailing Address 630 S. FRONTAGE RD NIPOMO Service Technician Performing Inspection RICK BINGER Contractor/Tank Tester License Number 902034 ICC Number 8452629 Expiration Date 03/16/2025 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date Franklin fueling 1018163709 2/15/2026 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected RP1200 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 8/19/2024 Total # of Pages Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) 87 Diesel 91 Are both vent and tank riser piping secondarily contained? ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No OPE Model Defender Defender Defender What is the OPE response when activated? (Check all that apply.) ☒ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm ☒ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm ☒ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm ☐ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ☐ Yes* ☒ No ☐ Yes* ☒ No ☐ Yes* ☒ No ☐ Yes* ☐ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) 106 105 106.75 What is the percent capacity of the tank at which the OPE activates? 94% 94% 94% Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ☒ Yes ☐ No ☒ Yes ☐ No ☒ Yes ☐ No ☐ Yes ☐ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☐ Pass ☐ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. OPI was tested for start up testing * Mark here if: ☐ Flow restrictors interfere with overfill prevention and equipment repairs required. TB0318-03 r2TECHNICALUPDATETB0318-03 r2TECHNICALUPDATE franklinfueling.com3760 Marsh Rd. • Madison, WI 53718, USATel: USA & Canada +1 800 225 9787 • Fax: +1 608 838 6433Tel: UK +44 (0) 1473 243300 • Tel: Mex 001 800 738 7610Tel: DE +49 6571 105 380 • Tel: CH +86 10 8565 4566 © 2022 Franklin Fueling Systems. All Rights Reserved. OPV CO-AXIAL DROP TUBE CALCULATION E-FORM NOTE: For exact dimensions, consult the manufacturer’s tank charts. Use the actual capacity of the tank for calculations. NFPA30 Guidelines limit tank fill to 95%. Actual Tank Capacity Gallons Final Shuto Volume Height X = =B (Multiply) Typically 95%** Fig. “B”Calculate Final Shuto Volume Final shuto volume (gallons) .95 To find Upper Drop Tube length “X” “A” “X” Upper Drop Tube Length = (Equals) To find Lower Drop Tube length “Y” “B” “Y” Lower Drop Tube Length - (Subtract) = (Equals) - (Subtract) - (Subtract) - (Subtract) "Final shutoff volume height"Drop tube seat surface to bottom of tank “B” "Final shutoff volume height OPV Length Offset15¾" (400 mm) Position and mounting adjustment2.5" (63.5 mm)Tank bottom clearance6" (152mm) Fig. “C” Poppeted Coaxial (EBW) Measure from retaining ring. Detail for “X/A”. “X” “A” “B” “A” “Y” “X” Defender Spill Containment (For Reference Only). Top of Tank Lower Drop Tube (U.S.T.) Overfill Prevention Valve Seat surface of upper drop tube. Final Shuto Volume** Bottom of Tank 6" (152 mm) Max* Fig. “A”(Not to scale.) *If local codes require this distance to be smaller, subtract less than 6" (152mm). Upper Drop Tube“X” “Y” TB0318-03 r2TECHNICALUPDATETB0318-03 r2TECHNICALUPDATE franklinfueling.com3760 Marsh Rd. • Madison, WI 53718, USATel: USA & Canada +1 800 225 9787 • Fax: +1 608 838 6433Tel: UK +44 (0) 1473 243300 • Tel: Mex 001 800 738 7610Tel: DE +49 6571 105 380 • Tel: CH +86 10 8565 4566 © 2022 Franklin Fueling Systems. All Rights Reserved. OPV CO-AXIAL DROP TUBE CALCULATION E-FORM NOTE: For exact dimensions, consult the manufacturer’s tank charts. Use the actual capacity of the tank for calculations. NFPA30 Guidelines limit tank fill to 95%. Actual Tank Capacity Gallons Final Shuto Volume Height X = =B (Multiply) Typically 95%** Fig. “B”Calculate Final Shuto Volume Final shuto volume (gallons) .95 To find Upper Drop Tube length “X” “A” “X” Upper Drop Tube Length = (Equals) To find Lower Drop Tube length “Y” “B” “Y” Lower Drop Tube Length - (Subtract) = (Equals) - (Subtract) - (Subtract) - (Subtract) "Final shutoff volume height"Drop tube seat surface to bottom of tank “B” "Final shutoff volume height OPV Length Offset15¾" (400 mm) Position and mounting adjustment2.5" (63.5 mm)Tank bottom clearance6" (152mm) Fig. “C” Poppeted Coaxial (EBW) Measure from retaining ring. Detail for “X/A”. “X” “A” “B” “A” “Y” “X” Defender Spill Containment (For Reference Only). Top of Tank Lower Drop Tube (U.S.T.) Overfill Prevention Valve Seat surface of upper drop tube. Final Shuto Volume** Bottom of Tank 6" (152 mm) Max* Fig. “A”(Not to scale.) *If local codes require this distance to be smaller, subtract less than 6" (152mm). Upper Drop Tube“X” “Y” OPV installation record sheet Date Installed Valve Serial Number _50 ___ _ ___ O Site information Site# I Description __________________________ _ Site Address Site Contact ____________________________ _ Installing Contractor Name _____________________________ _ Company ____________________________ _ Tank Information ProductType ___________________________ _ Underground Tank Manufacturer ______________________ _ Tank Full Volume --------------------------- Tank Diameter ___________________________ _ Tank Chart Available? D Yes D No Tank Type D Steel D Fiberglass D Square D Cylinder D Dome Ends Tank have compartments? D Yes D No Tank/ Drop Tube Measurements Upper Drop Tube Length (X) ____________ _ Lower Drop Tube Length (Y) ____________ _ Distance from Lower Drop tube to tank bottom _______ _ Operational Inspection Procedure Performed □Yes □No Initials Date Dimensions A _______ _ B _______ _ Final Shutoff Setpoint ______ Gallons ______ % Tank Fill 179" TB0318-03 r2TECHNICALUPDATETB0318-03 r2TECHNICALUPDATE franklinfueling.com3760 Marsh Rd. • Madison, WI 53718, USATel: USA & Canada +1 800 225 9787 • Fax: +1 608 838 6433Tel: UK +44 (0) 1473 243300 • Tel: Mex 001 800 738 7610Tel: DE +49 6571 105 380 • Tel: CH +86 10 8565 4566 © 2022 Franklin Fueling Systems. All Rights Reserved. OPV CO-AXIAL DROP TUBE CALCULATION E-FORM NOTE: For exact dimensions, consult the manufacturer’s tank charts. Use the actual capacity of the tank for calculations. NFPA30 Guidelines limit tank fill to 95%. Actual Tank Capacity Gallons Final Shuto Volume Height X = =B (Multiply) Typically 95%** Fig. “B”Calculate Final Shuto Volume Final shuto volume (gallons) .95 To find Upper Drop Tube length “X” “A” “X” Upper Drop Tube Length = (Equals) To find Lower Drop Tube length “Y” “B” “Y” Lower Drop Tube Length - (Subtract) = (Equals) - (Subtract) - (Subtract) - (Subtract) "Final shutoff volume height"Drop tube seat surface to bottom of tank “B” "Final shutoff volume height OPV Length Offset15¾" (400 mm) Position and mounting adjustment2.5" (63.5 mm)Tank bottom clearance6" (152mm) Fig. “C” Poppeted Coaxial (EBW) Measure from retaining ring. Detail for “X/A”. “X” “A” “B” “A” “Y” “X” Defender Spill Containment (For Reference Only). Top of Tank Lower Drop Tube (U.S.T.) Overfill Prevention Valve Seat surface of upper drop tube. Final Shuto Volume** Bottom of Tank 6" (152 mm) Max* Fig. “A”(Not to scale.) *If local codes require this distance to be smaller, subtract less than 6" (152mm). Upper Drop Tube“X” “Y”