Loading...
HomeMy WebLinkAboutOPI 2024CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION Installation Repair 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? Yes No Yes No Yes No Yes No OPE Model What is the OPE response when activated? (Check all that apply.) Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Shut off Flow Restricts Flow Audible Alarm Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? Yes* No Yes* No Yes* No Yes* No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? Yes No Yes* No Yes* No Yes* No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results Pass Fail Pass Fail Pass Fail Pass Fail 1 8. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. * Mark here if: Flow restrictors interfere with overfill prevention and equipment repairs required. 90 9684 44 54 1/2 79 1/2 10 1/2 9126 94 T1 87MCK 2708605 90 9684 94 41 51 3/4 10 3/4 79 1/4 9105 T2 89CK 2708605 90 9684 94 41 51 3/4 10 3/4 79 1/4 9105 T3 91CK 2708605 < I10100 OCT 25, 2024 11:37 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL > < I20100 OCT 25, 2024 11:37 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 UNL Premium 4386 4308 5298 41.18 0.00 85.44 2 UNL Plus NoBlend 4023 3936 5661 38.58 0.00 90.80 3 UNL Regular 6906 6800 2778 59.49 0.00 81.90 > < I51700 OCT 25, 2024 11:37 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM > < I60100 OCT 25, 2024 11:37 AM 1 TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL Premium ON 2 UNL Plus NoBlend ON 3 UNL Regular ON 4 87 UNLEADED OFF > < I60200 OCT 25, 2024 11:37 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL Premium 2 UNL Plus NoBlend 3 UNL Regular 4 87 UNLEADED > < I60300 OCT 25, 2024 11:37 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL Premium C 2 UNL Plus NoBlend B 3 UNL Regular A 4 87 UNLEADED 4 > < I60400 OCT 25, 2024 11:38 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL Premium 9684 2 UNL Plus NoBlend 9684 3 UNL Regular 9684 4 87 UNLEADED 9684 > < I60700 OCT 25, 2024 11:38 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 2 1 UNL Premium 90.00 2 UNL Plus NoBlend 90.00 3 UNL Regular 90.00 4 87 UNLEADED 90.00 > < I60900 OCT 25, 2024 11:38 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL Premium 0.000700 2 UNL Plus NoBlend 0.000700 3 UNL Regular 0.000700 4 87 UNLEADED 0.000070 > < I61200 OCT 25, 2024 11:38 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL Premium NONE NONE 2 UNL Plus NoBlend NONE NONE 3 UNL Regular NONE NONE 4 87 UNLEADED NONE NONE > < I62200 OCT 25, 2024 11:38 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 9200 2 UNL Plus NoBlend 9200 3 UNL Regular 9200 4 87 UNLEADED 9325 > < I62300 OCT 25, 2024 11:38 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 8716 2 UNL Plus NoBlend 8716 3 UNL Regular 8716 3 4 87 UNLEADED 8834 > < I62400 OCT 25, 2024 11:38 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL Premium 1.0 2 UNL Plus NoBlend 1.0 3 UNL Regular 1.0 > < I62800 OCT 25, 2024 11:38 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 9684 2 UNL Plus NoBlend 9684 3 UNL Regular 9684 4 87 UNLEADED 9816 > < I62900 OCT 25, 2024 11:38 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Premium 982 2 UNL Plus NoBlend 982 3 UNL Regular 982 4 87 UNLEADED 982 > < I70300 OCT 25, 2024 11:38 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 TURBINE TRI-STATE (SINGLE FLOAT) 3 89 ANNULAR TRI-STATE (SINGLE FLOAT) 4 89 TURBINE TRI-STATE (SINGLE FLOAT) 5 91 ANNULAR TRI-STATE (SINGLE FLOAT) 6 91 TURBINE TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 4 > < I20600 OCT 25, 2024 11:38 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 TANK ALARM HISTORY TANK 1 UNL Premium PROBE OUT JUL 18, 2022 3:03 PM HIGH WATER WARNING NOV 21, 2023 12:40 PM TANK 2 UNL Plus NoBlend PROBE OUT JUL 18, 2022 3:03 PM TANK 3 UNL Regular LOW PRODUCT ALARM MAR 25, 2024 11:41 AM AUG 28, 2023 4:54 PM INVALID FUEL LEVEL MAR 25, 2024 11:41 AM PROBE OUT JUL 18, 2022 3:03 PM DELIVERY NEEDED SEP 10, 2024 4:49 PM MAR 24, 2024 7:37 PM DEC 19, 2023 7:51 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 5 TANK 13 TANK 14 TANK 15 TANK 16 > < I30200 OCT 25, 2024 11:41 AM CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR OCT 25, 2024 8:55 AM FUEL ALARM OCT 25, 2024 8:55 AM FUEL ALARM OCT 11, 2023 6:23 AM FUEL ALARM 2 87 TURBINE OCT 25, 2024 8:52 AM FUEL ALARM OCT 25, 2024 8:52 AM FUEL ALARM OCT 25, 2024 8:50 AM FUEL ALARM 3 89 ANNULAR OCT 25, 2024 9:00 AM FUEL ALARM OCT 10, 2023 10:31 AM FUEL ALARM OCT 10, 2023 10:26 AM FUEL ALARM 4 89 TURBINE OCT 25, 2024 8:52 AM FUEL ALARM OCT 10, 2023 10:09 AM FUEL ALARM OCT 13, 2022 10:10 AM FUEL ALARM 5 91 ANNULAR OCT 25, 2024 9:02 AM FUEL ALARM OCT 25, 2024 9:02 AM FUEL ALARM OCT 10, 2023 10:37 AM FUEL ALARM 6 91 TURBINE OCT 25, 2024 8:53 AM FUEL ALARM OCT 10, 2023 10:08 AM FUEL ALARM OCT 13, 2022 10:09 AM FUEL ALARM > < I10100 OCT 25, 2024 11:41 AM 6 CIRCLE K 2708605 5600 AUBURN ST BAKERSFIELD CA,93306 661-871-7979 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL > < I90200 OCT 25, 2024 11:41 AM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM > 7