HomeMy WebLinkAbout2024-12-17 HAZMAT Inspection 5677 Gosford Rd - Buffalo Wild Wings.pdfCurrent Date:12/17/2024 16:05 Occupant:Buffalo Wild Wings 3527 Inspection Date: 12/17/2024 Occupant Name:Buffalo Wild Wings 3527 Inspection Date:12/17/2024 Street Number:5677 Occupant Code:97751 Street Name:Gosford City:Bakersfield Street Type:Road Postal Code:93311 Inspector:Pisano , Liseth State:California Passed:No Inspection Type:Hazmat Annual Violations Violation Code Description 5307.3.2 Gas detection system. Where ventilation is not provided in accordance with Section 5307.3.1, a gas detection system shall be provided in rooms or indoor areas and in below-grade outdoor locations with insulated carbon dioxide systems. Carbon dioxide sensors shall be provided within 12 inches (305 mm) of the floor in the area where the gas is expected to accumulate or other approved locations. The system shall be designed as follows: 1.Activates an audible and visible supervisory alarm at a normally attended location upon detection of a carbon dioxide concentration of 5,000 ppm (9000 mg/m3). 2.Activates an audible and visible alarm within the room or immediate area where the system is installed upon detection of a carbon dioxide concentration of 30,000 ppm (54 000 mg/m3). Violation Count:1 Inspection Fee:0.00 Type First Name Last Name Signature Date Signature Graphic Owner/Rep.Melissa Lamb 12/17/2024 Inspector Liseth Pisano 12/17/2024 Conducted an annual hazardous materials inspection. The following must be corrected within 24 hours. 1. The CO2 monitor must be repaired. It is turned off. Complete Inspection Report - With Documents Facility Information Inspection Information Signatures Inspection Notes Documents Page 1 of 4 Occupant:Buffalo Wild Wings 3527 Inspection Date: 12/17/2024 Current Date:12/17/2024 16:05 Inspection Documents Violation Documents Location Attributes:Commercial Hood; Fire Alarm; Fire Safety; HMBP; Sprinkler System Admin Information Page 2 of 4 Occupant:Buffalo Wild Wings 3527 Inspection Date: 12/17/2024 Current Date:12/17/2024 16:05 HazMat - HMBP Administration/Documentation Question Answer Notes Did the facility adequately establish and implement a business plan when storing/handling a hazardous material at or above reportable quantities in CERS? Yes Did the facility annually review and electronically certify in CERS that the business plan is complete and accurate on or before the required due date? Yes Does the facility have a copy of the business plan readily available with responsibilities for emergency response or training for review? Yes Did the facility update CERS within 30 days of any one or more of the following events: 1) A 100 percent or more increase in the quantity of a previously disclosed material. 2) Any handling of a previously undisclosed hazardous materials at or above reportable quantities. 3) A change of business address, business ownership, or business name. 4) A substantial change in the handler's operations that requires modification to any portion of the business plan. Yes Did the facility inform the property owner in writing that an HMBP is required for the facility? Yes Did the facility provide the property owner a copy of the HMBP upon request?? Yes Did the facility report complete or accurate information in the Business Activities Page and/or Business Owner Operator Identification Page in CERS? Yes Did the facility report complete and accurate hazardous material inventory information for all hazardous materials on site at or above reportable quantities in CERS? Yes Did the facility adequately establish an emergency response plan in CERS?Yes Did the facility submit a site map with all the required content in CERS?Yes Training Question Answer Notes Did the facility submit an adequate training program with safety procedures in the event of a release or threatened release of a hazardous material in CERS? Yes Page 3 of 4 Occupant:Buffalo Wild Wings 3527 Inspection Date: 12/17/2024 Current Date:12/17/2024 16:05 Did the facility provide initial and refresher training to all employees and maintain records for 3 years? Yes Operations/Maintenance Question Answer Notes Does the facility have adequate signage for hazardous materials storage?Yes Are hazardous materials separated form incompatibles?Yes Release/Leaks/Spills Question Answer Notes Did the facility fail to report a release or threatened release of a hazardous material to the unified program agency and to Cal OES? N/A Page 4 of 4