HomeMy WebLinkAbout2025-01-24 HMBP 5030 Gosford Rd. El Pollo Loco.pdfOccupant:El Pollo Loco Inspection
Date:
01/24/2025
Occupant Name:El Pollo Loco Inspection Date:01/24/2025
Street Number:5030 Occupant Code:104532
Street Name:Gosford City:Bakersfield
Street Type:Road Postal
Code:
93313
Inspector:Pisano , Liseth State:California
Passed:No
Inspection Type:Hazmat Annual
Current Date:01/24/2025 13:51
Complete Inspection Report - With Documents
Facility Information
Inspection Information
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Violations
Violation Code Description
901.6 Inspection, testing and maintenance.
Fire protection and life safety systems shall
be maintained in an operative condition at
all times, and shall be replaced or repaired
where defective. Nonrequired fire
protection and life safety systems and
equipment shall be inspected, tested and
maintained or removed in accordance with
Section 901.8. All fire alarm systems, fire
detection systems, automatic sprinkler or
extinguishing systems, communication
systems, and all other equipment, material
or systems required by these regulations
shall be maintained in an operable condition
at all times in accordance with this code and
California Code of Regulations, Title 19,
Division 1. Upon disruption or diminishment
of the fire protective qualities of such
equipment, material or systems, immediate
action shall be instituted to affect a
reestablishment of such equipment, material
or systems to their original normal and
operational condition. [California Code of
Regulations, Title 19, Division 1, §1.14]
Maintenance. Every fire alarm system or
device, sprinkler system, fire extinguisher,
fire hose, fire-resistive assembly or any other
fire safety assembly, device, material or
equipment installed and retained in service
in any building or structure subject to
California Code of Regulations, Title 19,
Division 1 regulations shall be maintained in
an operable condition at all times in
accordance with California Code of
Regulations, Title 19, Division 1 regulations
and with their intended use. [California Code
of Regulations, Title 19, Division 1, §3.24]
Maintenance of Equipment. All fire alarm
systems, fire detection systems, automatic
sprinkler or extinguishing systems,
communication systems, and all other
equipment, material or systems required by
California Code of Regulations, Title 19,
Division 1 shall be maintained in an operable
condition at all times. Upon disruption or
diminishment of the fire protective qualities
of such equipment, material or systems,
immediate action shall be instituted to
affect a reestablishment of such equipment
material or systems to their original normal
and operational condition. [California Code
of Regulations Title 19 Division 1 §904(a)]Current Date:01/24/2025 13:51
of Regulations, Title 19, Division 1, §904(a)]Required Inspection, Testing and
Maintenance Frequencies.
(a) All automatic fire extinguishing systems,
including systems installed as an alternate to
other building requirements, shall be
inspected, tested and maintained in
accordance with the following frequencies.
Local authorities may require more frequent
inspection, testing and maintenance and
additional procedures.
[California Code of Regulations, Title 19,
Division 1, §904(a)(1)] Required Inspection,
Testing and Maintenance Frequencies.
(1) Water-based fire protection systems shall
be inspected, tested and maintained in
accordance with the frequencies required by
NFPA 25 (2011 edition) including Annexes A,
B, C, D, E, F and G as amended by the State
of California. (Published as NFPA 25, 2013
California Edition.)
[California Code of Regulations, Title 19,
Division 1, §904(b)] Required Inspection,
Testing and Maintenance Frequencies.
(b) When proof of the installation date of
standpipe systems or automatic fire
sprinkler systems cannot be furnished, such
systems shall receive initial testing and
maintenance by July 1, 1985.
[California Code of Regulations, Title 19,
Division 1, §904.2(a)] Testing and
Maintenance Requirements.
(a) All testing and maintenance on automatic
fire extinguishing systems in accordance
with Health & Safety Code Section 13195
shall be performed by those licensed in
accordance with Health and Safety Code
Section 13196.5.
Exceptions:
(1) The State Fire Marshal may waive, in
writing, licensing of fire departments which
conduct fire sprinkler and standpipe system
testing and maintenance.
(2) Service on fire alarm systems and
industrial systems as specified in Health and
Safety Code Sections 13196.5(b) and (c) may
be conducted without a license.
(3) Testing and maintenance on automatic
fire extinguishing systems exempted in
writing by the State Fire Marshal, when the
building owner or occupant has the staff and
equipment to conduct testing and
maintenance.
[California Code of Regulations, Title 19,
Division 1, §904.2(b)] Testing and
Maintenance Requirements.
(b) Any testing and maintenance of
automatic fire extinguishing systems shall be
performed in accordance with these
i t
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
requirements.Exceptions:
(1) The State Fire Marshal may waive, in
writing, the requirement that testing and
maintenance be performed in accordance
with these requirements when a licensee can
demonstrate that a system cannot
functionally be tested and maintained in
accordance with the California Code of
Regulations, Title 19, Division 1, Chapter 5.
(2) If at any time a licensee encounters a
specialized or modified system which cannot
be tested and maintained in accordance with
California Code of Regulations, Title 19,
Division 1, Chapter 5, the licensee shall
contact the State Fire Marshal and test and
maintain the system as directed.
(A) The intent of this section is to cover
automatic fire extinguishing systems as
originally designed, installed and approved
by the Authority Having Jurisdiction. It is
not, however, intended to require that such
systems be upgraded to current adopted
standards.
[California Code of Regulations, Title 19,
Division 1, §904.2(h)] Testing and
Maintenance Requirements.
(h) At the time of testing and maintenance,
building management shall be consulted to
avoid unnecessary disturbance of normal
building operation.
[California Code of Regulations, Title 19,
Division 1, §904.2(i)] Testing and
Maintenance Requirements.
(i) The licensee shall contact the local fire
authority having jurisdiction prior to testing
and maintenance of a system when required
by the local fire authority having jurisdiction
to do so.
1010.2 Door operations.
Except as specifically permitted by this
section, egress doors shall be readily
openable from the egress side without the
use of a key or special knowledge or effort.
606.3.3.1 Inspection.
Hoods, grease-removal devices, fans, ducts
and other appurtenances shall be inspected
at intervals specified in Table 606.3.3.1 or as
approved by the fire code official.
Inspections shall be completed by qualified
individuals.
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Violation Count:3 Inspection Fee:0.00
Current Date:01/24/2025 13:51
Signatures
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Type
First
Name
Last
Name
Signature
Date Signature Graphic
Owner/
Rep.
Ana Solorio 01/24/2025
Inspect
or
Liseth Pisano 01/24/2025
Conducted a hazardous materials, fire safety, and commercial hood inspections. The following
must be corrected.
1. Service the fire extinguisher by the back door. It is missing the pin and zip tie.
2. A licensed commercial hood contractor must clean the hood and place a sticker with the date
it was cleaned.
3. Double doors must remain open during business hours. One door is locked.
4. Remove all stored items in the CO2/water heater room.
Current Date:01/24/2025 13:51
Inspection Notes
Documents
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Inspection Documents
Current Date:01/24/2025 13:51
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Violation Documents
Location Attributes:Commercial Hood; Fire Safety; HMBP
Current Date:01/24/2025 13:51
Admin Information
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
Fire Safety Inspection
Exterior
Question Answer Notes
Address visible from street?Yes
Hazardous or dead vegetation
or combustible material on
property
Yes
Fire lanes painted and
maintained Yes
OS&Y in good condition and
secured unobstructed Na
FDC are accessible NA
Audible alarm for sprinkler
system in good condition Na
Knoxbox present, keys secured
and correct keys Na
Private fire hydrants
maintained and tested Yes
3ft Clearence maintained
around fire hydrants Yes
Interior
Question Answer Notes
Fire Extinguishers must be
maintained, tested and
inspected
No
Exit signs fully illuminated in
normal and emergency mode Yes
Exit doors operable from
inside without special
knowledge or a key
No
Exit isles, hallways and stairs
clean of obstructions Yes
Circuit breakers properly
labeled Yes
Electrical outlets and junction
boxes properly covered Yes
Extension cords not being
used in lieu of permanent
wiring.
Yes
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
No items stored 24" non-
sprinklered or 18" sprinklered
ceilings.
Yes
No visible penetrations in
ceiling tile or holes in drywall Yes
Fire Alarm
Question Answer Notes
Fire alarm system tested and
maintained N/A
Fire Sprinkler
Question Answer Notes
Fire sprinkler system serviced
and maintained N/A
Commercial Hood
Question Answer Notes
Kitchen hood extinguishing
system serviced within the last
6 months
Yes
Kitchen hood has been
properly cleaned and serviced No
K class fire extinguisher is
present and serviced Yes
Hazmat
Question Answer Notes
Facility has reported into CERs Yes
CERs has been updated or
certified for current year Yes
Carbon monoxide detector
present and working Yes
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
HazMat - HMBP
Administration/Documentation
Question Answer Notes
Did the facility adequately
establish and implement a
business plan when
storing/handling a hazardous
material at or above
reportable quantities in CERS?
Yes
Did the facility annually review
and electronically certify in
CERS that the business plan is
complete and accurate on or
before the required due date?
Yes
Does the facility have a copy of
the business plan readily
available with responsibilities
for emergency response or
training for review?
Yes
Did the facility update CERS
within 30 days of any one or
more of the following events:
1) A 100 percent or more
increase in the quantity of a
previously disclosed material.
2) Any handling of a previously
undisclosed hazardous
materials at or above
reportable quantities. 3) A
change of business address,
business ownership, or
business name. 4) A
substantial change in the
handler's operations that
requires modification to any
portion of the business plan.
Yes
Did the facility inform the
property owner in writing that
an HMBP is required for the
facility?
Yes
Did the facility provide the
property owner a copy of the
HMBP upon request??
Yes
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51
Did the facility report
complete or accurate
information in the Business
Activities Page and/or
Business Owner Operator
Identification Page in CERS?
Yes
Did the facility report
complete and accurate
hazardous material inventory
information for all hazardous
materials on site at or above
reportable quantities in CERS?
Yes
Did the facility adequately
establish an emergency
response plan in CERS?
Yes
Did the facility submit a site
map with all the required
content in CERS?
Yes
Training
Question Answer Notes
Did the facility submit an
adequate training program
with safety procedures in the
event of a release or
threatened release of a
hazardous material in CERS?
Yes
Did the facility provide initial
and refresher training to all
employees and maintain
records for 3 years?
Yes
Operations/Maintenance
Question Answer Notes
Does the facility have
adequate signage for
hazardous materials storage?
Yes
Are hazardous materials
separated form incompatibles?Yes
Release/Leaks/Spills
Question Answer Notes
Did the facility fail to report a
release or threatened release
of a hazardous material to the
unified program agency and to
Cal OES?
N/A
Occupant:El Pollo Loco Inspection
Date:
01/24/2025
Current Date:01/24/2025 13:51