Loading...
HomeMy WebLinkAbout2025-02-07 Inspection Report 4625 Buena Vista Rd Harris Ranch.pdfCurrent Date:02/07/2025 15:30 Occupant:Harris Ranch Express Inspection Date: 02/07/2025 Occupant Name:Harris Ranch Express Inspection Date:02/07/2025 Street Number:4625 Occupant Code:11112326 Street Name:Buena Vista City:Bakersfield Street Type:Road Postal Code:93311 Inspector:Pisano , Liseth State:California Occupant Suite:B Passed:No Building Number: #3 Inspection Type:Fire Safety Inspection Violations Violation Code Description HSC 6.95 25507 Failure to adequately establish and implement a business plan when storing/handling a hazardous material at or above reportable quantities. 506.1 Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037, and shall contain keys to gain necessary access as required by the fire code official. 603.6 Extension cords. Extension cords shall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 703.1 Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire-resistance-rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer’s installation instructions. HSC 25515 Failure to report to CERs and submit a business plan, inventory and site map. HSC 25505 Failure to complete and electronically submit initially, annually or triennially, a business plan when storing/handling Complete Inspection Report - With Documents Facility Information Inspection Information Page 1 of 4 Occupant:Harris Ranch Express Inspection Date: 02/07/2025 Current Date:02/07/2025 15:30 a hazardous material at or above reportable quantities. 5307.3.2 Gas detection system. Where ventilation is not provided in accordance with Section 5307.3.1, a gas detection system shall be provided in rooms or indoor areas and in below-grade outdoor locations with insulated carbon dioxide systems. Carbon dioxide sensors shall be provided within 12 inches (305 mm) of the floor in the area where the gas is expected to accumulate or other approved locations. The system shall be designed as follows: 1.Activates an audible and visible supervisory alarm at a normally attended location upon detection of a carbon dioxide concentration of 5,000 ppm (9000 mg/m3). 2.Activates an audible and visible alarm within the room or immediate area where the system is installed upon detection of a carbon dioxide concentration of 30,000 ppm (54 000 mg/m3). Violation Count:7 Inspection Fee:113.00 Type First Name Last Name Signature Date Signature Graphic Owner/Rep.Roger Vanderberg 02/07/2025 Inspector Liseth Pisano 02/07/2025 Conducted a fire safety inspection for permit numbers Shell: 23-13863 & Harris Ranch: 24-3045. The following are outstanding and must be corrected within 30 days. 1. A licensed contractor must obtained an Above Ground Storage Tank (AST) permit with the Bakersfield Fire Department. 2. A Carbon Dioxide CO2 detector/monitor with a horn strobe must be installed near the CO2. 3. Report the CO2 in the California Environmental Reporting System (CERS). 4. Replace missing ceiling tiles throughout the building. 5. Remove the extension cord in the office. All electrical must be connected directly to an electrical outlet. 6. Provide master key/s to the building and electrical room to be placed in the KnoxBox. Inspection Documents Violation Documents Signatures Inspection Notes Documents Page 2 of 4 Occupant:Harris Ranch Express Inspection Date: 02/07/2025 Current Date:02/07/2025 15:30 Fire Safety Inspection Exterior Question Answer Notes Address visible from street?Yes Hazardous or dead vegetation or combustible material on property Yes Fire lanes painted and maintained Yes OS&Y in good condition and secured unobstructed Na FDC are accessible NA Audible alarm for sprinkler system in good condition Na Knoxbox present, keys secured and correct keys No Private fire hydrants maintained and tested Yes 3ft Clearence maintained around fire hydrants Yes Interior Question Answer Notes Fire Extinguishers must be maintained, tested and inspected Yes Exit signs fully illuminated in normal and emergency mode Yes Exit doors operable from inside without special knowledge or a key Yes Exit isles, hallways and stairs clean of obstructions Yes Circuit breakers properly labeled Yes Electrical outlets and junction boxes properly covered Yes Extension cords not being used in lieu of permanent wiring.No No items stored 24" non-sprinklered or 18" sprinklered ceilings.Yes No visible penetrations in ceiling tile or holes in drywall No Fire Alarm Question Answer Notes Fire alarm system tested and maintained Yes Fire Sprinkler Question Answer Notes Fire sprinkler system serviced and maintained N/A Commercial Hood Page 3 of 4 Occupant:Harris Ranch Express Inspection Date: 02/07/2025 Current Date:02/07/2025 15:30 Question Answer Notes Kitchen hood extinguishing system serviced within the last 6 months Kitchen hood has been properly cleaned and serviced K class fire extinguisher is present and serviced Hazmat Question Answer Notes Facility has reported into CERs No CERs has been updated or certified for current year No Carbon monoxide detector present and working No Page 4 of 4