HomeMy WebLinkAboutSB989 2025Appendix VII Underground Storage Tank Secondary Containment Testing Report Form CERS = California Environmental Reporting System, ICC = International Code Council, ID = Identification, NA = Not Applicable, UDC = Under-Dispenser Containment, Page 1 of 5 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 6 Month ܆ 36 Month CERS ID Test Date Facility Name Facility Address City ZIP Code Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date Manufacturer and Test Equipment Training Certifications Expiration Date Test Procedures Used Components Tested I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 1. FACILITY INFORMATION 2. SERVICE TECHNICIAN INFORMATION 3. TRAINING AND CERTIFICATIONS 4. TEST PROCEDURE INFORMATION 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST 10134226 1/28/25 Jaco #3346 Fastrip #621 805 34th St Bakersfield 93301 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Zachary Elder 1073967 10381559 05/06/26 INCON 4528403716 06/17/2026 Incon Sumps and UDC’s Precision mechanical test gauge Tank annular’s and line secondaries 1/28/25 6 Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 2 of 5 Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Test Equipment Used: Tank ID Tank Manufacturer Tank Capacity Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Test Equipment Used: Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Additional copies of this page may be attached. 6. TANK SECONDARY CONTAINMENT TEST 7. PIPE SECONDARY CONTAINMENT TEST Vacuum gauges T1 87 Modern welding 12,000 1pm 10Hg 2pm 10Hg 0 0 Pressure gauges 87-1 Unknown 1pm 5psi 2pm 5psi 0 0 T2 87-2 Modern welding 12,000 1pm 10Hg 2pm 10Hg 0 0 91 Modern welding 12,000 1pm 10Hg 2pm 10Hg 0 0 DSL Modern welding 12,000 1pm 10Hg 2pm 10Hg 0 0 87-2 Unknown 1pm 5psi 2pm 5psi 0 0 91 Unknown 1pm 5psi 2pm 5psi 0 0 DSL Unknown 1pm 5psi 2pm 5psi 0 0 Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 3 of 5 Test Method Developed by ܆܆ Manufacturer ܆ Industry Standard ܆ Professional Engineer Test Type ܆ Pressure ܆ Vacuum ܆ Hydrostatic Test Equipment Used: Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST 87-1 Unknown 60” 24” 12:58 1.1339 1:13 1.1335 .000 .002 1-2 Unknown 36” 12” 2:51 3.1120 3:06 3.1120 .000 .002 87-2 Unknown 60” 24” 12:09 2.0938 12:24 2.0941 .002 .002 91 Unknown 60” 24” 12:09 3.0109 12:24 3.0109 .000 .002 DSL Unknown 60” 24” 12:58 3.0133 1:13 3.0132 .002 .002 3-4 Unknown 36” 12” 12:53 2.7673 1:09 2.7675 .002 .002 5-6 Unknown 36” 12” 12:53 1.4673 1:09 1.4675 .002 .002 7-8 Unknown 36” 12” 2:27 4.2853 2:42 4.2855 .002 .002 Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 4 of 5 Test Method Developed by ܆܆ Manufacturer ܆ Industry Standard ܆ Professional Engineer Test Type ܆ Pressure ܆ Vacuum ܆ Hydrostatic Test Equipment Used: Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST (continued) ܆ Pass ܆ Fail Trans East Unknown 36” 12” 2:27 2.7531 2:42 2.7525 .002 .002 Trans West Unknown 36” 12” 12:53 1.6589 1:09 1.7086 .002 .002 Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 5 of 5 9. COMMENTS INCON F,ASTRI IP 805 34ST BAKERSFIELD CA 93301 1-800-984-6266 05/21/2007 1:13 AM SUMP LEAK TEST REPORT 87-lSTP TEST STARTED 12:58 AM TEST STARTED 06/21/2007 BEGIN LEVEL 1.1339 IN END TIME 1:13 AM END DATE 06/21/2007 END LEVEL 1.1335 IN LEAK THRESHOLD 0.002 IN TEST RESULT PASSED DSL STP TEST STARTED 12:58 AM TEST STARTED 06/21/2007 BEGIN LEVEL 3.0133 IN END TIME 1:13 AM END DATE 06/21/2007 END LEVEL 3.0132 IN LEAK THRESHOLD 0.002 IN TEST RESULT PASSED INCON tiSTRIIP 805 34ST BA�ERSFIELD CA 93301 1-800-984-6266 06/21/2007 12:24 AM SUMP LEAK TEST REPORT 87-2STP TEST STARTED 12:09 AM TEST STARTED 06/21/2007 BEGIN LEVEL 2.0938 IN END TIME 12:24 AM END DATE 06/21/2007 END LEVEL 2.0941 IN LEAK THRESHOLD 0.002 IN TEST RESULT PASSED 91 STP TEST STARTED TEST STARTED BEGIN LEVEL END TIME END DATE END LEVEL LEAK THRESHOLD TEST RESULT 12:09 AM 06/21/2007 3. 0109 IN12:24 AM06/21/2007 3.0101 IN0.002 INPASSED TEST PERFORMED ON 1/28/2025, INCON DATE AND TIME WAS INCORRECT