HomeMy WebLinkAbout2025-02-20 Cabaret Inspection 1207 19th St The Mint Bar.pdfCurrent Date:02/20/2025 11:50 Occupant:The Mint Bar Inspection Date: 02/20/2025 Occupant Name:The Mint Bar Inspection Date:02/20/2025 Street Number:1207 Street Name:19th City:Bakersfield Street Type:Street Postal Code:93301 Inspector:Pisano , Liseth State:CA Passed:No Inspection Type:Cabaret license inspection Violations Violation Code Description 603.2.2 Open electrical terminations. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.6 Extension cords. Extension cords shall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. HSC 25515 Failure to report to CERs and submit a business plan, inventory and site map. HSC 25505 Failure to complete and electronically submit initially, annually or triennially, a business plan when storing/handling a hazardous material at or above reportable quantities. 5307.3.2 Gas detection system. Where ventilation is not provided in accordance with Section 5307.3.1, a gas detection system shall be provided in rooms or indoor areas and in below-grade outdoor locations with insulated carbon dioxide systems. Carbon dioxide sensors shall be provided within 12 inches (305 mm) of the floor in the area where the gas is expected to accumulate or other approved locations. The system shall be designed as follows: 1.Activates an audible and visible supervisory alarm at a normally attended location upon detection of a carbon dioxide concentration of 5,000 ppm (9000 mg/m3). 2.Activates an audible and visible alarm within the room or immediate area where the system is installed upon detection of a carbon dioxide concentration of 30,000 ppm (54 000 mg/m3). Violation Count:5 Inspection Fee:0.00 Complete Inspection Report - With Documents Facility Information Inspection Information Page 1 of 4 Occupant:The Mint Bar Inspection Date: 02/20/2025 Current Date:02/20/2025 11:50 Type First Name Last Name Signature Date Signature Graphic Owner/Rep.Walter Walston 02/20/2025 Inspector Liseth Pisano 02/20/2025 Conducted a Cabaret Inspection. The following must be corrected within 30 days. 1. Close open electrical in the restroom ceiling. 2. Reminder to service all fire extinguishers on or before 2/29/2025. 3. Remove the green extension cord behind the bar. Extension cords are not allowed. 4. The facility has a bulk CO2 tank. The CO2 tank must be reported in the California Environmental Reporting System (CERS). 5. Install a CO2 or carbon dioxide detector near the soda dispenser. Inspection Documents Violation Documents Signatures Inspection Notes Documents Page 2 of 4 Occupant:The Mint Bar Inspection Date: 02/20/2025 Current Date:02/20/2025 11:50 Fire Safety Inspection Exterior Question Answer Notes Address visible from street?Yes Hazardous or dead vegetation or combustible material on property Yes Fire lanes painted and maintained Yes OS&Y in good condition and secured unobstructed Na FDC are accessible NA Audible alarm for sprinkler system in good condition Na Knoxbox present, keys secured and correct keys Na Private fire hydrants maintained and tested Yes 3ft Clearence maintained around fire hydrants Yes Interior Question Answer Notes Fire Extinguishers must be maintained, tested and inspected Yes Exit signs fully illuminated in normal and emergency mode Yes Exit doors operable from inside without special knowledge or a key Yes Exit isles, hallways and stairs clean of obstructions Yes Circuit breakers properly labeled Yes Electrical outlets and junction boxes properly covered No Extension cords not being used in lieu of permanent wiring.No No items stored 24" non-sprinklered or 18" sprinklered ceilings.Yes No visible penetrations in ceiling tile or holes in drywall Yes Fire Alarm Question Answer Notes Fire alarm system tested and maintained N/A Fire Sprinkler Question Answer Notes Fire sprinkler system serviced and maintained N/A Commercial Hood Page 3 of 4 Occupant:The Mint Bar Inspection Date: 02/20/2025 Current Date:02/20/2025 11:50 Question Answer Notes Kitchen hood extinguishing system serviced within the last 6 months N/A Kitchen hood has been properly cleaned and serviced N/A K class fire extinguisher is present and serviced N/A Hazmat Question Answer Notes Facility has reported into CERs No CERs has been updated or certified for current year No Carbon monoxide detector present and working No Page 4 of 4