HomeMy WebLinkAboutEMC 2025 (VEEDER ROOT UPGRADE)Appendix VI
Underground Storage Tank
Monitoring System Certification Form
CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification,
ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-
Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank,
VPH = Vacuum/Pressure/Hydrostatic
Page 1 of 6
TYPE OF ACTION ܆܆ Installation ܈ Repair ܆ 12 Month
1. FACILITY INFORMATION
CERS ID
10117291
Certification Date
03/5/2025
Facility Name
PENSKE CA-604
Facility Address
2929 E BRUNDAGE
City
BAKERSFIELD
ZIP Code
93307
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Certification
WESTERN PUMP, INC.
Phone
619-239-9988
Mailing Address
3235 F. STREET, SAN DIEGO CA 92102
Service Technician Performing Test
CHRIS MIZICKO
Contractor/Tank Tester License Number
673853
ICC Number
8276846
ICC Expiration Date
12/16/2026
3. TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
ICC #8276846 12/16/2026
VEEDER ROOT #B37435 01/06/2027
4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that the monitoring system is operational in accordance with California Code
of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting
documentation is attached; and all information contained herein is accurate.
Service Technician Signature Date
03/5/2025
Total # of Pages ce Technician Sign
11
Underground Storage Tank
Monitoring System Certification Form
Page 2 of 6
5. MONITORING SYSTEM AND PROGRAMMING
A separate Monitoring System Certification Form must be prepared for each control panel.
Make of Monitoring System
Control Panel
VEEDER ROOT
Model of Monitoring System
Control Panel
TLS 450 PLUS
Software Version Installed
10.P.233.58
Attach the post-certification reports if the monitoring system is capable of generating
either; ܈܈Monitoring System Set-up ܈܈ Alarm History Report Yes No NA
All monitoring equipment is operational per manufacturer’s specifications? ܈܈܆܆
Secondary containment systems are free of damage, debris, or liquid? ܈܈܆܆
Are the audible and visual alarms operational? ܈܈܆܆
All sensors have been: 1) visually inspected for wiring kinks, breaks and residual
buildup on floats; and 2) tested for functionality and confirmed operational? ܈܈܆܆܆܆
Are all sensors installed to detect a release at the earliest opportunity in the
secondary containment? ܈܈܆܆܆܆
The monitoring system set-up was reviewed, and proper settings confirmed? ܈܈܆܆܆܆
Was the monitoring control panel’s backup battery visually inspected, functionally
tested, and confirmed operational? ܈܈܆܆܆܆
Does the flow of fuel stop at the dispenser if a release is detected in the under-
dispenser containment? ܈܈܆܆܆܆
Does the turbine automatically shut down if the piping secondary containment
monitoring system fails to operate or is electrically disconnected? ܈܈܆܆܆܆
Does the turbine automatically shut down if the piping secondary containment
monitoring system detects a release? Which sensors initiate positive shut down?
(Check all that apply) ܈ Sump ܈ UDC
܈܈܆܆܆܆
If monitoring system alarms are relayed to a remote monitoring center, is all
communication equipment operational? ܆܆܆܆܈܈
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
Underground Storage Tank
Monitoring System Certification Form
Page 3 of 6
6. SENSOR TESTING RESULTS
List only sensors tested on date of this certification. List “Sensor ID” as labeled in system
programming. Additional copies of this page may be attached to accommodate all sensors tested.
Sensor ID Sensor Model Component(s) Monitored Pass Fail
L1 794380-301 DIESEL T1 ANNULAR ܈܈ ܆܆
L2 794380-323 DIESEL FILL SUMP ܈܈ ܆܆
L3 794380-323 DIESEL STP SUMP ܈܈ ܆܆
L4 794390-409 DEF ANNULAR ܈܈ ܆܆
L5 794380-323 DEF STP ܈܈ ܆܆
L6 794380-304 DIESEL FILL BRINE ܈܈ ܆܆
L7 794380-304 DIESEL STP BRINE ܈܈ ܆܆
L8 794380-304 DEF STP BRINE ܈܈ ܆܆
L9 794380-323 UDC 1 ܈܈ ܆܆
L10 794380-323 UDC 2 ܈܈ ܆܆
L11 794380-323 UDC 3 ܈܈ ܆܆
L12 794380-304 UDC 1 ANNULAR ܈܈ ܆܆
L13 794380-304 UDC 2 ANNULAR ܈܈ ܆܆
L14 794380-304 UDC 3 ANNULAR ܈܈ ܆܆
L15 794380-323 VENT SUMP ܈܈ ܆܆
L16 794380-304 VENT SUMP BRINE ܈܈ ܆܆
VS 1 857280-100 DIESEL ALL LINES VAC ܈܈ ܆܆
VS 2 857280-100 DEF ALL LINES VAC ܈܈ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
Underground Storage Tank
Monitoring System Certification Form
Page 5 of 6
8. IN-TANK GAUGING TESTING
܆܆ Check this box if tank gauging is used only for inventory control.
܆܆ Check this box if NO tank gauging equipment is installed.
(Do not complete this section if either box is checked.)
Yes No NA
All wiring has been: 1) visually inspected for kinks, breaks and proper entry and
termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆
Were all in-tank gauging probes visually inspected for damage and residue buildup
to ensure that floats move freely, functionally tested, and confirmed operational? ܈܈ ܆܆ ܆܆
Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆
Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆
Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆
Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆
Probe ID Probe Model Tanks Monitored Pass Fail
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
܆܆ ܆܆
9. COMMENTS
Describe all answers marked “No” or “Fail” and proposed remedy.
List all monitoring equipment either replaced or repaired.