Loading...
HomeMy WebLinkAbout2025-03-31 HMBP 1534 19th St Tina Marie's.pdfCurrent Date:03/31/2025 13:02 Occupant:TINA MARIE'S (PREVIOUSLY CHEFS CHOICE) Inspection Date: 03/31/2025 Occupant Name:TINA MARIE'S (PREVIOUSLY CHEFS CHOICE) Inspection Date:03/31/2025 Street Number:1534 Occupant Code:116783 Street Name:19th City:Bakersfield Street Type:Street Postal Code:93301 Inspector:Pisano , Liseth State:California Passed:No Inspection Type:Hazmat Annual Violations Violation Code Description 1008.1 Means of egress illumination. Illumination shall be provided in the means of egress in accordance with Section 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. 5307.3.2 Gas detection system. Where ventilation is not provided in accordance with Section 5307.3.1, a gas detection system shall be provided in rooms or indoor areas and in below-grade outdoor locations with insulated carbon dioxide systems. Carbon dioxide sensors shall be provided within 12 inches (305 mm) of the floor in the area where the gas is expected to accumulate or other approved locations. The system shall be designed as follows: 1.Activates an audible and visible supervisory alarm at a normally attended location upon detection of a carbon dioxide concentration of 5,000 ppm (9000 mg/m3). 2.Activates an audible and visible alarm within the room or immediate area where the system is installed upon detection of a carbon dioxide concentration of 30,000 ppm (54 000 mg/m3). 703.1 Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire-resistance-rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer’s installation instructions. Violation Count:3 Inspection Fee:0.00 Complete Inspection Report - With Documents Facility Information Inspection Information Signatures Page 1 of 4 Occupant:TINA MARIE'S (PREVIOUSLY CHEFS CHOICE) Inspection Date: 03/31/2025 Current Date:03/31/2025 13:02 Type First Name Last Name Signature Date Signature Graphic Owner/Rep.Taylor Barber 03/31/2025 Inspector Liseth Pisano 03/31/2025 Conducted a hazardous materials and fire safety inspection. The following must be corrected within 30 days. 1. Repair the horn strobe for the commercial hood. Device must be properly installed. 2. The CO2 monitor is in error. The CO2 must be normal. 3. Replace the missing ceiling tile in the back hallway CO2 area. 4. Repair the emergency exit signs in the back hallway CO2 area. 5. Replace missing door on the breaker panel in the back hallway CO2 area. Inspection Documents Violation Documents Location Attributes:Commercial Hood; HMBP Inspection Notes Documents Admin Information Page 2 of 4 Occupant:TINA MARIE'S (PREVIOUSLY CHEFS CHOICE) Inspection Date: 03/31/2025 Current Date:03/31/2025 13:02 Fire Safety Inspection Exterior Question Answer Notes Address visible from street?Yes Hazardous or dead vegetation or combustible material on property Yes Fire lanes painted and maintained Yes OS&Y in good condition and secured unobstructed Na FDC are accessible NA Audible alarm for sprinkler system in good condition Na Knoxbox present, keys secured and correct keys Na Private fire hydrants maintained and tested Yes 3ft Clearence maintained around fire hydrants Yes Interior Question Answer Notes Fire Extinguishers must be maintained, tested and inspected Yes Exit signs fully illuminated in normal and emergency mode No Exit doors operable from inside without special knowledge or a key Yes Exit isles, hallways and stairs clean of obstructions Yes Circuit breakers properly labeled Yes Electrical outlets and junction boxes properly covered Yes Extension cords not being used in lieu of permanent wiring.Yes No items stored 24" non-sprinklered or 18" sprinklered ceilings.Yes No visible penetrations in ceiling tile or holes in drywall No Fire Alarm Question Answer Notes Fire alarm system tested and maintained N/A Fire Sprinkler Question Answer Notes Fire sprinkler system serviced and maintained N/A Commercial Hood Page 3 of 4 Occupant:TINA MARIE'S (PREVIOUSLY CHEFS CHOICE) Inspection Date: 03/31/2025 Current Date:03/31/2025 13:02 Question Answer Notes Kitchen hood extinguishing system serviced within the last 6 months Yes Kitchen hood has been properly cleaned and serviced Yes K class fire extinguisher is present and serviced Yes Hazmat Question Answer Notes Facility has reported into CERs Yes CERs has been updated or certified for current year Yes Carbon monoxide detector present and working No Page 4 of 4